TIMER — Timer/counter

This peripheral is a general purpose timer designed to keep track of time in user-selective time intervals, it can operate in two modes: timer and counter.

Figure 1. Block schematic for timer/counter

The timer/counter runs on the high-frequency clock source (HFCLK) and includes a four-bit (1/2X) prescaler that can divide the timer input clock from the HFCLK controller. Clock source selection between PCLK16M and PCLK1M is automatic according to TIMER base frequency set by the prescaler. The TIMER base frequency is always given as 16 MHz divided by the prescaler value.

The PPI system allows a TIMER event to trigger a task of any other system peripheral of the device. The PPI system also enables the TIMER task/event features to generate periodic output and PWM signals to any GPIO. The number of input/outputs used at the same time is limited by the number of GPIOTE channels.

TIMER can operate in two modes: Timer mode and Counter mode. In both modes, TIMER is started by triggering the START task, and stopped by triggering the STOP task. After the timer is stopped the timer can resume timing/counting by triggering the START task again. When timing/counting is resumed, the timer will continue from the value it had prior to being stopped.

In Timer mode, the TIMER's internal Counter register is incremented by one for every tick of the timer frequency fTIMER as illustrated in Block schematic for timer/counter. The timer frequency is derived from PCLK16M as shown in the following example, using the values specified in the PRESCALER register.


    fTIMER = 16 MHz / (2PRESCALER)
    

When fTIMER ≤ 1 MHz, TIMER will use PCLK1M instead of PCLK16M for reduced power consumption.

In counter mode, the TIMER's internal Counter register is incremented by one each time the COUNT task is triggered, meaning the timer frequency and the prescaler are not utilized in counter mode. Similarly, the COUNT task has no effect in Timer mode.

The TIMER's maximum value is configured by changing the bit-width of the timer in register BITMODE.

PRESCALER and BITMODE must only be updated when the timer is stopped. If these registers are updated while the timer is started, unpredictable behavior may occur.

When the timer is incremented beyond its maximum value, the Counter register will overflow and the timer will automatically start over from zero.

The Counter register can be cleared by triggering the CLEAR task. This will explicitly set the internal value to zero.

TIMER implements multiple capture/compare registers.

Independent of prescaler setting, the accuracy of TIMER is equivalent to one tick of the timer frequency fTIMER as illustrated in Block schematic for timer/counter.

Capture

TIMER implements one capture task for every available capture/compare register.

Every time the CAPTURE[n] task is triggered, the Counter value is copied to the CC[n] register.

Compare

TIMER implements one COMPARE event for every available capture/compare register.

A COMPARE event is generated when the Counter is incremented and then becomes equal to the value specified in one of the capture compare registers. When the Counter value becomes equal to the value specified in a capture compare register CC[n], the corresponding compare event COMPARE[n] is generated.

BITMODE specifies how many bits of the Counter register and the capture/compare register that are used when the comparison is performed. Other bits will be ignored.

Task delays

After TIMER is started, the CLEAR, COUNT, and STOP tasks are guaranteed to take effect within one clock cycle of the PCLK16M.

Task priority

If the START task and the STOP task are triggered at the same time, meaning within the same period of PCLK16M, the STOP task will be prioritized.

Registers

Table 1. Instances
Base addressPeripheralInstanceDescriptionConfiguration
0x40008000TIMERTIMER0Timer 0This timer instance has 4 CC registers (CC[0..3]) 
0x40009000TIMERTIMER1Timer 1This timer instance has 4 CC registers (CC[0..3]) 
0x4000A000TIMERTIMER2Timer 2This timer instance has 4 CC registers (CC[0..3]) 
Table 2. Register overview
RegisterOffsetDescription
TASKS_START0x000Start Timer 
TASKS_STOP0x004Stop Timer 
TASKS_COUNT0x008Increment Timer (Counter mode only) 
TASKS_CLEAR0x00CClear time 
TASKS_SHUTDOWN0x010Shut down timerDeprecated
TASKS_CAPTURE[0]0x040Capture Timer value to CC[0] register 
TASKS_CAPTURE[1]0x044Capture Timer value to CC[1] register 
TASKS_CAPTURE[2]0x048Capture Timer value to CC[2] register 
TASKS_CAPTURE[3]0x04CCapture Timer value to CC[3] register 
TASKS_CAPTURE[4]0x050Capture Timer value to CC[4] register 
TASKS_CAPTURE[5]0x054Capture Timer value to CC[5] register 
EVENTS_COMPARE[0]0x140Compare event on CC[0] match 
EVENTS_COMPARE[1]0x144Compare event on CC[1] match 
EVENTS_COMPARE[2]0x148Compare event on CC[2] match 
EVENTS_COMPARE[3]0x14CCompare event on CC[3] match 
EVENTS_COMPARE[4]0x150Compare event on CC[4] match 
EVENTS_COMPARE[5]0x154Compare event on CC[5] match 
SHORTS0x200Shortcuts between local events and tasks 
INTENSET0x304Enable interrupt 
INTENCLR0x308Disable interrupt 
MODE0x504Timer mode selection 
BITMODE0x508Configure the number of bits used by the TIMER 
PRESCALER0x510Timer prescaler register 
CC[0]0x540Capture/Compare register 0 
CC[1]0x544Capture/Compare register 1 
CC[2]0x548Capture/Compare register 2 
CC[3]0x54CCapture/Compare register 3 
CC[4]0x550Capture/Compare register 4 
CC[5]0x554Capture/Compare register 5 

TASKS_START

Address offset: 0x000

Start Timer

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_START  Start Timer
   Trigger1Trigger task

TASKS_STOP

Address offset: 0x004

Stop Timer

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_STOP  Stop Timer
   Trigger1Trigger task

TASKS_COUNT

Address offset: 0x008

Increment Timer (Counter mode only)

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_COUNT  Increment Timer (Counter mode only)
   Trigger1Trigger task

TASKS_CLEAR

Address offset: 0x00C

Clear time

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_CLEAR  Clear time
   Trigger1Trigger task

TASKS_SHUTDOWN ( Deprecated )

Address offset: 0x010

Shut down timer

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_SHUTDOWN  Shut down timerDeprecated
   Trigger1Trigger task

TASKS_CAPTURE[n] (n=0..5)

Address offset: 0x040 + (n × 0x4)

Capture Timer value to CC[n] register

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
AWTASKS_CAPTURE  Capture Timer value to CC[n] register
   Trigger1Trigger task

EVENTS_COMPARE[n] (n=0..5)

Address offset: 0x140 + (n × 0x4)

Compare event on CC[n] match

Bit number313029282726252423222120191817161514131211109876543210
ID                               A
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
ARWEVENTS_COMPARE  Compare event on CC[n] match
   NotGenerated0Event not generated
   Generated1Event generated

SHORTS

Address offset: 0x200

Shortcuts between local events and tasks

Bit number313029282726252423222120191817161514131211109876543210
ID                  LKJIHG  FEDCBA
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
A-FRWCOMPARE[i]_CLEAR (i=0..5)  Shortcut between event COMPARE[i] and task CLEAR
   Disabled0Disable shortcut
   Enabled1Enable shortcut
G-LRWCOMPARE[i]_STOP (i=0..5)  Shortcut between event COMPARE[i] and task STOP
   Disabled0Disable shortcut
   Enabled1Enable shortcut

INTENSET

Address offset: 0x304

Enable interrupt

Bit number313029282726252423222120191817161514131211109876543210
ID          FEDCBA                
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
A-FRWCOMPARE[i] (i=0..5)  Write '1' to enable interrupt for event COMPARE[i]
   Set1Enable
   Disabled0Read: Disabled
   Enabled1Read: Enabled

INTENCLR

Address offset: 0x308

Disable interrupt

Bit number313029282726252423222120191817161514131211109876543210
ID          FEDCBA                
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
A-FRWCOMPARE[i] (i=0..5)  Write '1' to disable interrupt for event COMPARE[i]
   Clear1Disable
   Disabled0Read: Disabled
   Enabled1Read: Enabled

MODE

Address offset: 0x504

Timer mode selection

Bit number313029282726252423222120191817161514131211109876543210
ID                              AA
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
ARWMODE  Timer mode
   Timer0Select Timer mode
   Counter1Select Counter modeDeprecated
   LowPowerCounter2Select Low Power Counter mode

BITMODE

Address offset: 0x508

Configure the number of bits used by the TIMER

Bit number313029282726252423222120191817161514131211109876543210
ID                              AA
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
ARWBITMODE  Timer bit width
   16Bit016 bit timer bit width
   08Bit18 bit timer bit width
   24Bit224 bit timer bit width
   32Bit332 bit timer bit width

PRESCALER

Address offset: 0x510

Timer prescaler register

Bit number313029282726252423222120191817161514131211109876543210
ID                            AAAA
Reset 0x0000000400000000000000000000000000000100
IDAccessFieldValue IDValueDescription
ARWPRESCALER [0..9]Prescaler value

CC[n] (n=0..5)

Address offset: 0x540 + (n × 0x4)

Capture/Compare register n

Bit number313029282726252423222120191817161514131211109876543210
IDAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Reset 0x0000000000000000000000000000000000000000
IDAccessFieldValue IDValueDescription
ARWCC  

Capture/Compare value

Only the number of bits indicated by BITMODE will be used by the TIMER.

Electrical specification