Recommended operating conditions

The operating conditions are the physical parameters that the chip can operate within.

Table 1. Recommended operating conditions
SymbolParameterNotesMin.Nom.Max.Units
VDDSupply voltage, independent of DCDC enable1.73.03.6V
tR_VDDSupply rise time (0 V to 1.7 V) 60ms
TAOperating temperature-402585°C
Important: The on-chip power-on reset circuitry may not function properly for rise times longer than the specified maximum.

WLCSP light sensitivity

All WLCSP package variants are sensitive to visible and close-range infrared light. This means that a final product design must shield the chip properly, either by final product encapsulation or by shielding/coating of the WLCSP device.