SPIS Electrical specification
SPIS slave interface electrical specifications
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| fSPIS | Bit rates for SPIS1 | | | 82 | Mbps |
| tSPIS,START | Time from RELEASE task to receive/transmit (CSN active) | | 1 | | µs |
1 High bit rates may require GPIOs to be set as High Drive, see GPIO chapter for more details.
2 The actual maximum data rate depends on the master's CLK to SDO and SDI setup and hold timings.
Serial Peripheral Interface Slave (SPIS) timing specifications
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,CSCKIN | SCK input period | 125 | | | ns |
| tSPIS,RFSCKIN | SCK input rise/fall time | | | 30 | ns |
| tSPIS,WHSCKIN | SCK input high time | 30 | | | ns |
| tSPIS,WLSCKIN | SCK input low time | 30 | | | ns |
| tSPIS,SUCSN | CSN to CLK setup time | 10001 | | | ns |
| tSPIS,HCSN | CLK to CSN hold time | 1000 | | | ns |
| tSPIS,ASA | CSN to SDO driven | | | 70 | ns |
| tSPIS,ASO | CSN to SDO valid2 | | | 1000 | ns |
| tSPIS,DISSO | CSN to SDO disabled2 | | | 70 | ns |
| tSPIS,CWH | CSN inactive time | 300 | | | ns |
Figure 1. SPIS timing diagram, CPHA = 0
Figure 2. SPIS timing diagram, CPHA = 1
Figure 3. Common SPIM and SPIS timing diagram
1 Excluding any start-up delay for the high frequency clock in low power mode.
2 At 25pF load, including GPIO capacitance, see GPIO spec.
Timing specifications for GPIO port P0 using Standard drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 59 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 6 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 33 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 1 | | | ns |
Timing specifications for GPIO port P0 using High drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 56 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 6 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 33 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 1 | | | ns |
Timing specifications for GPIO port P1 using Standard drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 43 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 5 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 5 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 2 | | | ns |
Timing specifications for GPIO port P1 using High drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 39 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 5 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 5 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 2 | | | ns |
Timing specifications for GPIO port P2 using Standard drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 43 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 5 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 6 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 0 | | | ns |
Timing specifications for GPIO port P2 using High drive strength
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 39 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 5 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 6 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 1 | | | ns |
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|
| tSPIS,VSO | CLK edge to SDO valid | | | 15 | ns |
| tSPIS,HSO | SDO hold time after CLK edge | 3 | | | ns |
| tSPIS,SUSI | SDI to CLK edge setup time | 6 | | | ns |
| tSPIS,HSI | CLK edge to SDI hold time | 1 | | | ns |