Recommended operating conditions

The operating conditions are the physical parameters that the device can operate within.

Table 1. Recommended operating conditions
SymbolParameterMin.Nom.Max.Units
VDDVDD supply voltage1.73.6V
VDDEXTVDD supply voltage under extended operating temperature1.73.4V
VDDPORVDD supply voltage needed during power-on reset1.75V
TAOperating temperature-402585°C
TAEXTExtended operating temperature85105°C
TRSTRecommended storage temperature40°C
RHRSTRecommended storage relative humidity90%