TWIS Electrical specification

TWIS slave timing specifications

SymbolDescriptionMin.Typ.Max.Units
fTWIS,SCLBit rates for TWIS7100400kbps
tTWIS,STARTTime from PREPARERX/PREPARETX task to ready to receive/transmit1.5µs
tTWIS,SU_DATIInput data setup time before positive edge on SCL – all modes20ns
tTWIS,HD_DATIInput data hold time after negative edge on SCL – all modes0ns
tTWIS,HD_DATOOutput data hold time after negative edge on SCL – all modes350600ns
tTWIS,HD_STA,100kbpsTWI slave hold time from for START condition (SDA low to SCL low), 100 kbps500ns
tTWIS,HD_STA,400kbpsTWI slave hold time from for START condition (SDA low to SCL low), 400 kbps500ns
tTWIS,SU_STO,100kbpsTWI slave setup time from SCL high to STOP condition, 100 kbps500ns
tTWIS,SU_STO,400kbpsTWI slave setup time from SCL high to STOP condition, 400 kbps500ns
tTWIS,BUF,100kbpsTWI slave bus free time between STOP and START conditions, 100 kbps500ns
tTWIS,BUF,400kbpsTWI slave bus free time between STOP and START conditions, 400 kbps500ns
Figure 7. TWIS timing diagram, 1 byte transaction
TWIS timing diagram, 1 byte transaction
7 High bit rates or stronger pull-ups may require GPIOs to be set as High Drive, see GPIO chapter for more details.