QDEC Electrical specification

QDEC Electrical Specification

SymbolDescriptionMin.Typ.Max.Units
tSAMPLE

Time between sampling signals from quadrature decoder

128131072µs
tLED

Time from LED is turned on to signals are sampled

0511µs