TDM Electrical specification
TDM timing specification
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| fMCK | MCK frequency | 12288 | kHz | ||
| fSCK | SCK frequency | 12288 | kHz |
Timing specifications for Slave mode
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| tS_SDIN | SDIN setup time before SCK rising | 6 | ns | ||
| tH_SDIN | SDIN hold time after SCK rising | 0 | ns | ||
| tS_SDOUT | SCK falling edge to SDOUT valid | 31 | ns | ||
| tH_SDOUT | SDOUT hold time after SCK falling | 5 | ns |
Timing specifications for Master mode
| Symbol | Description | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| tS_SDIN | SDIN setup time before SCK rising | 36 | ns | ||
| tH_SDIN | SDIN hold time after SCK rising | 0 | ns | ||
| tS_SDOUT | SCK falling edge to SDOUT valid | 7 | ns | ||
| tH_SDOUT | SDOUT hold time after SCK falling | 4 | ns |