Recommended operating conditions

The operating conditions are the physical parameters that the device can operate within.

Table 1. Recommended operating conditions
SymbolParameterMin.Nom.Max.Units
VDDVDD supply voltage1.73.6V
VBUSVBUS powers the USB physical interface3.675.05.5V
TAOperating temperature-402585°C
TRSTRecommended storage temperature40°C
RHRSTRecommended storage relative humidity90%
Note: VDD supply is required for device operation. VBUS is optional and is only used to supply the USB physical interface when the USB interface is in use. VBUS cannot be used to power the device.