4. CRC calculation unit

This section applies to the whole STM32F4xx family, unless otherwise specified.

4.1 CRC introduction

The CRC (cyclic redundancy check) calculation unit is used to get a CRC code from a 32-bit data word and a fixed generator polynomial.

Among other applications, CRC-based techniques are used to verify data transmission or storage integrity. In the scope of the EN/IEC 60335-1 standard, they offer a means of verifying the flash memory integrity. The CRC calculation unit helps compute a signature of the software during runtime, to be compared with a reference signature generated at link-time and stored at a given memory location.

4.2 CRC main features

The block diagram is shown in Figure 8.

Figure 8. CRC calculation unit block diagram

Block diagram of the CRC calculation unit showing the AHB bus, Data register (output), CRC computation block, and Data register (input) with 32-bit read and write access paths.
graph TD
    AHB[AHB bus]
    DRout[Data register (output)]
    CRC[CRC computation (polynomial: 0x4C11DB7)]
    DRin[Data register (input)]

    AHB --> DRout
    DRout -- "32-bit (read access)" --> AHB
    DRout --> CRC
    CRC --> DRin
    DRin -- "32-bit (write access)" --> CRC
  

The diagram illustrates the internal structure of the CRC calculation unit. At the top is the AHB bus, which connects to the Data register (output). The Data register (output) provides a 32-bit read access to the AHB bus and feeds into the CRC computation block. The CRC computation block, which uses the polynomial 0x4C11DB7, outputs the result to the Data register (input). The Data register (input) provides a 32-bit write access to the CRC computation block. The entire unit is enclosed in a box with the reference code 'ai14968' in the bottom right corner.

Block diagram of the CRC calculation unit showing the AHB bus, Data register (output), CRC computation block, and Data register (input) with 32-bit read and write access paths.

4.3 CRC functional description

The CRC calculation unit mainly consists of a single 32-bit data register, which:

Each write operation into the data register creates a combination of the previous CRC value and the new one (CRC computation is done on the whole 32-bit data word, and not byte per byte).

The write operation is stalled until the end of the CRC computation, thus allowing back-to-back write accesses or consecutive write and read accesses.

The CRC calculator can be reset to 0xFFFF FFFF with the RESET control bit in the CRC_CR register. This operation does not affect the contents of the CRC_IDR register.

4.4 CRC registers

The CRC calculation unit contains two data registers and a control register.The peripheral
The CRC registers have to be accessed by words (32 bits).

4.4.1 Data register (CRC_DR)

Address offset: 0x00
Reset value: 0xFFFF FFFF

31302928272625242322212019181716
DR [31:16]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
1514131211109876543210
DR [15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:0 Data register bits
Used as an input register when writing new data into the CRC calculator.
Holds the previous CRC calculation result when it is read.

4.4.2 Independent data register (CRC_IDR)

Address offset: 0x04
Reset value: 0x0000 0000

31302928272625242322212019181716
Reserved
1514131211109876543210
ReservedIDR[7:0]
rwrwrwrwrwrwrwrw
ST logo
ST logo

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:0 General-purpose 8-bit data register bits

Can be used as a temporary storage location for one byte.
This register is not affected by CRC resets generated by the RESET bit in the CRC_CR register.

4.4.3 Control register (CRC_CR)

Address offset: 0x08

Reset value: 0x0000 0000

31302928272625242322212019181716
Reserved
1514131211109876543210
ReservedRESET
w

Bits 31:1 Reserved, must be kept at reset value.

Bit 0 RESET bit

Resets the CRC calculation unit and sets the data register to 0xFFFF FFFF.
This bit can only be set, it is automatically cleared by hardware.

4.4.4 CRC register map

The following table provides the CRC register map and reset values.

Table 22. CRC calculation unit register map and reset values

OffsetRegister31-2423-1615-876543210
0x00CRC_DRData register
Reset value0xFFFF FFFF
0x04CRC_IDRReservedIndependent data register
Reset value0x00
0x08CRC_CRReservedRESET
Reset value0
ST logo