17. Advanced-control timers (TIM1 and TIM8)

This section applies to the whole STM32F4xx family, unless otherwise specified.

17.1 TIM1 and TIM8 introduction

The advanced-control timers (TIM1 and TIM8) consist of a 16-bit auto-reload counter driven by a programmable prescaler.

It may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM, complementary PWM with dead-time insertion).

Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler and the RCC clock controller prescalers.

The advanced-control (TIM1 and TIM8) and general-purpose (TIMx) timers are completely independent, and do not share any resources. They can be synchronized together as described in Section 17.3.20.

17.2 TIM1 and TIM8 main features

TIM1 and TIM8 timer features include:

Figure 86. Advanced-control timer block diagram

Advanced-control timer block diagram showing internal components including Trigger controller, Slave mode controller, Encoder interface, PSC prescaler, CNT counter, AutoReload Register, Repetition counter, Capture/Compare registers 1 through 4, DTG dead-time generators, and input/output interfaces.

The block diagram shows the internal architecture of the advanced-control timer:

Legend:
↗ Interrupt & DMA output
↘ Event

MS39906V3

Advanced-control timer block diagram showing internal components including Trigger controller, Slave mode controller, Encoder interface, PSC prescaler, CNT counter, AutoReload Register, Repetition counter, Capture/Compare registers 1 through 4, DTG dead-time generators, and input/output interfaces.

17.3 TIM1 and TIM8 functional description

17.3.1 Time-base unit

The main block of the programmable advanced-control timer is a 16-bit counter with its related auto-reload register. The counter can count up, down or both up and down. The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. Writing to or reading from the auto-reload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the auto-reload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow (or underflow when downcounting) and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detailed for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).

Note that the counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 87 and Figure 88 give some examples of the counter behavior when the prescaler ratio is changed on the fly:

Figure 87. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for Figure 87 showing the transition of prescaler division from 1 to 2. It includes waveforms for CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter.

The diagram illustrates the timing of a prescaler division change from 1 to 2. The CK_PSC signal is a continuous clock. The CEN signal transitions from low to high, enabling the counter. The Timerclock = CK_CNT signal is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. The Update event (UEV) is a pulse at the end of each counter rollover. The Prescaler control register is written with 0 and then 1. The Prescaler buffer reflects the new value 1. The Prescaler counter counts from 0 to 1, then resets to 0.

MS31076V2

Timing diagram for Figure 87 showing the transition of prescaler division from 1 to 2. It includes waveforms for CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter.

Figure 88. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for Figure 88 showing the transition of prescaler division from 1 to 4. It includes waveforms for CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter.

The diagram illustrates the timing of a prescaler division change from 1 to 4. The CK_PSC signal is a continuous clock. The CEN signal transitions from low to high, enabling the counter. The Timerclock = CK_CNT signal is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. The Update event (UEV) is a pulse at the end of each counter rollover. The Prescaler control register is written with 0 and then 3. The Prescaler buffer reflects the new value 3. The Prescaler counter counts from 0 to 3, then resets to 0.

MS31077V2

Timing diagram for Figure 88 showing the transition of prescaler division from 1 to 4. It includes waveforms for CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter.

17.3.2 Counter modes

Upcounting mode

In upcounting mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

If the repetition counter is used, the update event (UEV) is generated after upcounting is repeated for the number of times programmed in the repetition counter register plus one (TIMx_RCR+1). Else the update event is generated at each counter overflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 89. Counter timing diagram, internal clock divided by 1

Timing diagram for counter upcounting mode showing CK_PSC, CNT_EN, Timerclock, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

The diagram illustrates the timing of various signals during an upcounting cycle. The counter register counts from 31 to 36, then wraps around to 00 and continues up to 07. A counter overflow occurs at the transition from 36 to 00, which also triggers the Update event (UEV) and sets the Update interrupt flag (UIF). The Timerclock is derived from CK_PSC, and CNT_EN is the counter enable signal.

SignalState / Value
CK_PSCContinuous square wave
CNT_ENHigh (enabled)
Timerclock = CK_CNTContinuous square wave
Counter register31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07
Counter overflowPulse at transition 36 to 00
Update event (UEV)Pulse at transition 36 to 00
Update interrupt flag (UIF)High after transition 36 to 00

MS31078V3

Timing diagram for counter upcounting mode showing CK_PSC, CNT_EN, Timerclock, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 90. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is active high, enabling the counter. The Timerclock = CK_CNT signal is derived from CK_PSC and has a period twice that of CK_PSC. The Counter register shows a sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, 0003. A Counter overflow occurs when the counter reaches 0036 and rolls over to 0000. This overflow triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF). The reference code MS31079V3 is located in the bottom right corner.

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 91. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram shows the counter operation with the internal clock divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is active high. The Timerclock = CK_CNT signal has a period four times that of CK_PSC. The Counter register values shown are 0035, 0036, 0000, and 0001. A Counter overflow occurs at the transition from 0036 to 0000, generating an Update event (UEV) and setting the Update interrupt flag (UIF). The reference code MS31080V3 is in the bottom right corner.

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 92. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram depicts the counter operation with the internal clock divided by an arbitrary factor N. The CK_PSC signal is a high-frequency square wave. The Timerclock = CK_CNT signal has a period N times that of CK_PSC. The Counter register values shown are 1F, 20, and 00. A Counter overflow occurs when the counter transitions from 20 to 00, which generates an Update event (UEV) and sets the Update interrupt flag (UIF). The reference code MS31081V3 is in the bottom right corner.

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 93. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Figure 93: Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

A timing diagram showing counter operation when ARPE=0 (auto-reload preload disabled):
- CK_PSC: Input clock waveform.
- CEN: Counter enable goes high to start the counter.
- Timerclock = CK_CNT: Starts pulsing after CEN is asserted.
- Counter register: Counts 31, 32, 33, 34, 35, 36, then rolls over to 00, 01, 02, 03, 04, 05, 06, 07.
- Counter overflow: Pulses high when counter reaches 36 and rolls over to 00.
- Update event (UEV): Pulses simultaneously with counter overflow.
- Update interrupt flag (UIF): Latches high upon UEV.
- Auto-reload preload register: Value changes from FF to 36 when a new value is written to TIMx_ARR (takes effect immediately because ARPE=0).
- MS31082V3

Figure 93: Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Figure 94. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Figure 94: Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

A timing diagram showing counter operation when ARPE=1 (auto-reload preload enabled):
- CK_PSC: Input clock waveform.
- CEN: Counter enable goes high.
- Timerclock = CK_CNT: Clock waveform active after CEN enables counting.
- Counter register: Counts F0, F1, F2, F3, F4, F5, then rolls over to 00, 01, 02, 03, 04, 05, 06, 07.
- Counter overflow: Pulses high when counter reaches F5 and rolls over to 00.
- Update event (UEV): Pulses simultaneously with counter overflow.
- Update interrupt flag (UIF): Latches high upon UEV.
- Auto-reload preload register: Value changes from F5 to 36 when TIMx_ARR is written.
- Auto-reload shadow register: Holds value F5 until the next UEV occurs, at which point it is updated to 36.
- MS31083V2

Figure 94: Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Downcounting mode

In downcounting mode, the counter counts from the auto-reload value (content of the TIMx_ARR register) down to 0, then restarts from the auto-reload value and generates a counter underflow event.

If the repetition counter is used, the update event (UEV) is generated after downcounting is repeated for the number of times programmed in the repetition counter register plus one (TIMx_RCR+1). Else the update event is generated at each counter underflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV update event can be disabled by software by setting the UDIS bit in TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter restarts from the current auto-reload value, whereas the counter of the prescaler restarts from 0 (but the prescale rate doesn't change).

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 95. Counter timing diagram, internal clock divided by 1

Timing diagram for counter with internal clock divided by 1. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values (05 to 2F), Counter underflow (cnt_udf), Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The CK_PSC signal is a periodic clock. The CNT_EN signal is an enable signal that starts high and then goes low. The Timerclock = CK_CNT signal is a clock signal that starts after CNT_EN goes high. The Counter register shows the sequence of values: 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F. The Counter underflow (cnt_udf) signal is a pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) signal is a pulse that occurs when the counter reaches 00.

MS31184V1

Timing diagram for counter with internal clock divided by 1. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values (05 to 2F), Counter underflow (cnt_udf), Update event (UEV), and Update interrupt flag (UIF).

Figure 96. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values (002 to 0033), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a periodic clock. The CNT_EN signal is an enable signal that starts high and then goes low. The Timerclock = CK_CNT signal is a clock signal that starts after CNT_EN goes high. The Counter register shows the sequence of values: 002, 001, 000, 0036, 0035, 0034, 0033. The Counter underflow signal is a pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) signal is a pulse that occurs when the counter reaches 00.

MS31185V1

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values (002 to 0033), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 97. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is an enable signal that starts high and then goes low. The Timerclock = CK_CNT signal is a square wave with a frequency that is one-fourth of CK_PSC. The Counter register shows the count values: 0001, 0000, 0036, and 0035. The Counter underflow signal is a pulse that occurs when the counter reaches 0000. The Update event (UEV) signal is a pulse that occurs when the counter reaches 0036. The Update interrupt flag (UIF) signal is a pulse that occurs when the counter reaches 0035.

MS40510V1

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 98. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by N. The CK_PSC signal is a high-frequency square wave. The Timerclock = CK_CNT signal is a square wave with a frequency that is 1/N of CK_PSC. The Counter register shows the count values: 20, 1F, 00, and 36. The Counter underflow signal is a pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a pulse that occurs when the counter reaches 36. The Update interrupt flag (UIF) signal is a pulse that occurs when the counter reaches 36.

MS31187V1

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).
Figure 99. Counter timing diagram, update event when repetition counter is not used Timing diagram for counter update event when repetition counter is not used. The diagram shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register. The counter register shows values 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F. The auto-reload preload register shows FF and 36. A write to TIMx_ARR is indicated.

The diagram illustrates the timing of a counter update event. It shows the following signals and registers over time:

MS31188V1

Timing diagram for counter update event when repetition counter is not used. The diagram shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register. The counter register shows values 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F. The auto-reload preload register shows FF and 36. A write to TIMx_ARR is indicated.

Center-aligned mode (up/down counting)

In center-aligned mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register) – 1, generates a counter overflow event, then counts from the auto-reload value down to 1 and generates a counter underflow event. Then it restarts counting from 0.

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are not equal to '00'. The Output compare interrupt flag of channels configured in output is set when: the counter counts down (Center aligned mode 1, CMS = "01"), the counter counts up (Center aligned mode 2, CMS = "10") the counter counts up and down (Center aligned mode 3, CMS = "11").

In this mode, the DIR direction bit in the TIMx_CR1 register cannot be written. It is updated by hardware and gives the current direction of the counter.

The update event can be generated at each counter overflow and at each counter underflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event. In this case, the counter restarts counting from 0, as well as the counter of the prescaler.

The UEV update event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter continues counting up and down, based on the current auto-reload value.

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an UEV update event but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies.

Figure 100. Counter timing diagram, internal clock divided by 1, TIMx_ARR=0x6

Timing diagram for Figure 100 showing CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter underflow, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter with an internal clock divided by 1 and an auto-reload value (ARR) of 0x6. The signals shown are:

MS31189V2

Timing diagram for Figure 100 showing CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter underflow, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).
  1. 1. Here, center-aligned mode 1 is used (for more details refer to Section 17.4: TIM1 and TIM8 registers).

Figure 101. Counter timing diagram, internal clock divided by 2

Timing diagram for Figure 101 showing CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter with an internal clock divided by 2 and center-aligned mode 1. The signals shown are:

MS31190V2

Timing diagram for Figure 101 showing CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 102. Counter timing diagram, internal clock divided by 4, TIMx_ARR=0x36

Timing diagram for Figure 102 showing CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 0034, 0035, 0036, and 0035. The diagram shows an overflow event when the counter reaches 0036 and wraps to 0035.

CK_PSC

CNT_EN

Timerclock = CK_CNT

Counter register

0034 0035 0036 0035

Counter overflow

Update event (UEV)

Update interrupt flag (UIF)

MS31191V2

Timing diagram for Figure 102 showing CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 0034, 0035, 0036, and 0035. The diagram shows an overflow event when the counter reaches 0036 and wraps to 0035.
  1. 1. Center-aligned mode 2 or 3 is used with an UIF on overflow.

Figure 103. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 103 showing CK_PSC, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 20, 1F, 01, and 00. The diagram shows an underflow event when the counter wraps from 01 to 00.

CK_PSC

Timerclock = CK_CNT

Counter register

20 1F 01 00

Counter underflow

Update event (UEV)

Update interrupt flag (UIF)

MS31192V2

Timing diagram for Figure 103 showing CK_PSC, Timerclock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 20, 1F, 01, and 00. The diagram shows an underflow event when the counter wraps from 01 to 00.

Figure 104. Counter timing diagram, update event with ARPE=1 (counter underflow)

Timing diagram for counter underflow with ARPE=1. It shows the relationship between CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The counter register counts down from 06 to 00, then overflows to 07. The update event occurs on the rising edge of the counter overflow signal. The auto-reload preload register is updated with a new value (FD) before the update event.

CK_PSC

CEN

Timer clock = CK_CNT

Counter register: 06 | 05 | 04 | 03 | 02 | 01 | 00 | 01 | 02 | 03 | 04 | 05 | 06 | 07

Counter overflow

Update event (UEV)

Update interrupt flag (UIF)

Auto-reload preload register: FD | 36

Write a new value in TIMx_ARR

Auto-reload active register: FD | 36

MS31193V3

Timing diagram for counter underflow with ARPE=1. It shows the relationship between CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The counter register counts down from 06 to 00, then overflows to 07. The update event occurs on the rising edge of the counter overflow signal. The auto-reload preload register is updated with a new value (FD) before the update event.

Figure 105. Counter timing diagram, Update event with ARPE=1 (counter overflow)

Timing diagram for counter overflow with ARPE=1. It shows the relationship between CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The counter register counts up from F7 to 2F, then overflows to 30. The update event occurs on the rising edge of the counter overflow signal. The auto-reload preload register is updated with a new value (FD) before the update event.

CK_PSC

CEN

Timer clock = CK_CNT

Counter register: F7 | F8 | F9 | FA | FB | FC | 36 | 35 | 34 | 33 | 32 | 31 | 30 | 2F

Counter overflow

Update event (UEV)

Update interrupt flag (UIF)

Auto-reload preload register: FD | 36

Write a new value in TIMx_ARR

Auto-reload active register: FD | 36

MS31194V2

Timing diagram for counter overflow with ARPE=1. It shows the relationship between CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The counter register counts up from F7 to 2F, then overflows to 30. The update event occurs on the rising edge of the counter overflow signal. The auto-reload preload register is updated with a new value (FD) before the update event.

17.3.3 Repetition counter

Section 17.3.1 describes how the update event (UEV) is generated with respect to the counter overflows/underflows. It is actually generated only when the repetition counter has reached zero. This can be useful when generating PWM signals.

This means that data are transferred from the preload registers to the shadow registers (TIMx_ARR auto-reload register, TIMx_PSC prescaler register, but also TIMx_CCRx capture/compare registers in compare mode) every N+1 counter overflows or underflows, where N is the value in the TIMx_RCR repetition counter register.

The repetition counter is decremented:

The repetition counter is an auto-reload type; the repetition rate is maintained as defined by the TIMx_RCR register value (refer to Figure 106). When the update event is generated by software (by setting the UG bit in TIMx_EGR register) or by hardware through the slave mode controller, it occurs immediately whatever the value of the repetition counter is and the repetition counter is reloaded with the content of the TIMx_RCR register.

In center-aligned mode, for odd values of RCR, the update event occurs either on the overflow or on the underflow depending on when the RCR register was written and when the counter was started. If the RCR was written before starting the counter, the UEV occurs on the overflow. If the RCR was written after starting the counter, the UEV occurs on the underflow. For example for RCR = 3, the UEV is generated on each 4th overflow or underflow event depending on when RCR was written.

Figure 106. Update rate examples depending on mode and TIMx_RCR register settings

Timing diagrams for Counter-aligned and Edge-aligned modes showing update events (UEV) for various TIMx_RCR settings.

The figure illustrates update rate examples for advanced-control timers (TIM1 and TIM8) based on the mode and TIMx_RCR register settings. It is divided into two main sections: Counter-aligned mode and Edge-aligned mode.

Counter-aligned mode: Shows the relationship between the counter (TIMx_CNT) and update events (UEV) for different TIMx_RCR values. The counter is a sawtooth wave. UEVs are indicated by upward arrows. For TIMx_RCR = 0, there are 8 UEVs per counter period. For TIMx_RCR = 1, there are 4 UEVs. For TIMx_RCR = 2, there are 2 UEVs. For TIMx_RCR = 3, there are 2 UEVs, but they are spaced out. For TIMx_RCR = 3 and re-synchronization, there are 2 UEVs, with a note "(by SW)" indicating software control.

Edge-aligned mode: Shows the relationship between the counter and UEVs for different TIMx_RCR values. The counter is a sawtooth wave. UEVs are indicated by upward arrows. For TIMx_RCR = 0, there are 8 UEVs per counter period. For TIMx_RCR = 1, there are 4 UEVs. For TIMx_RCR = 2, there are 2 UEVs. For TIMx_RCR = 3, there are 2 UEVs, but they are spaced out. For TIMx_RCR = 3 and re-synchronization, there are 2 UEVs, with a note "(by SW)" indicating software control.

Legend: UEV → Update event: Preload registers transferred to active registers and update interrupt generated. Update Event if the repetition counter underflow occurs when the counter is equal to the auto-reload value.

MSv31195V1

Timing diagrams for Counter-aligned and Edge-aligned modes showing update events (UEV) for various TIMx_RCR settings.

17.3.4 Clock selection

The counter clock can be provided by the following clock sources:

Internal clock source (CK_INT)

If the slave mode controller is disabled (SMS=000), then the CEN, DIR (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except UG which remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 107 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 107. Control circuit in normal mode, internal clock divided by 1

Timing diagram for Figure 107 showing the behavior of the control circuit and upcounter in normal mode without a prescaler. The diagram includes waveforms for Internal clock, CEN=CNTE_N, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and Counter register. The Counter register shows values from 31 to 07, with a transition from 31 to 32 occurring on the rising edge of the Counter clock.

The diagram illustrates the timing relationship between various signals in normal mode without a prescaler. The Internal clock is a continuous square wave. The CEN=CNTE_N signal is a high-level pulse that enables the counter. The UG (Update Generator) signal is a high-level pulse that occurs when the counter reaches its limit (31) and rolls over to 00. The CNT_INIT signal is a high-level pulse that occurs when the counter is initialized to 00. The Counter clock = CK_CNT = CK_PSC is a square wave that is synchronized with the Internal clock. The Counter register shows the sequence of values from 31 to 07, with a transition from 31 to 32 occurring on the rising edge of the Counter clock.

MS31085V2

Timing diagram for Figure 107 showing the behavior of the control circuit and upcounter in normal mode without a prescaler. The diagram includes waveforms for Internal clock, CEN=CNTE_N, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and Counter register. The Counter register shows values from 31 to 07, with a transition from 31 to 32 occurring on the rising edge of the Counter clock.

External clock source mode 1

This mode is selected when SMS=111 in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.

Figure 108. TI2 external clock connection example

Block diagram of TI2 external clock connection example showing signal flow from TI2 through Filter and Edge detector, multiplexed by CC2P into TI2FP2, then TS[2:0] selector, and finally SMS[2:0] selector outputting CK_PSC.

MS31196V1

Block diagram of TI2 external clock connection example showing signal flow from TI2 through Filter and Edge detector, multiplexed by CC2P into TI2FP2, then TS[2:0] selector, and finally SMS[2:0] selector outputting CK_PSC.

For example, to configure the upcounter to count in response to a rising edge on the TI2 input, use the following procedure:

  1. 1. Configure channel 2 to detect rising edges on the TI2 input by writing CC2S = ‘01’ in the TIMx_CCMR1 register.
  2. 2. Configure the input filter duration by writing the IC2F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC2F=0000).
  3. 3. Select rising edge polarity by writing CC2P=0 and CC2NP=0 in the TIMx_CCER register.
  4. 4. Configure the timer in external clock mode 1 by writing SMS=111 in the TIMx_SMCR register.
  5. 5. Select TI2 as the trigger input source by writing TS=110 in the TIMx_SMCR register.
  6. 6. Enable the counter by writing CEN=1 in the TIMx_CR1 register.

Note: The capture prescaler is not used for triggering, so the user does not need to configure it.

When a rising edge occurs on TI2, the counter counts once and the TIF flag is set.

The delay between the rising edge on TI2 and the actual clock of the counter is due to the resynchronization circuit on TI2 input.

Figure 109. Control circuit in external clock mode 1

Timing diagram for external clock mode 1 showing TI2, CNT_EN, Counter clock, Counter register, and TIF signals.

The diagram illustrates the control circuit in external clock mode 1. It shows the following signals over time:

MS31087V2

Timing diagram for external clock mode 1 showing TI2, CNT_EN, Counter clock, Counter register, and TIF signals.

External clock source mode 2

This mode is selected by writing ECE=1 in the TIMx_SMCR register.

The counter can count at each rising or falling edge on the external trigger input ETR.

Figure 110 gives an overview of the external trigger input block.

Figure 110. External trigger input block

Block diagram of the external trigger input block showing the signal flow from ETR pin to CK_PSC.

The block diagram shows the external trigger input block. The signal flow is as follows:

MS33116V1

Block diagram of the external trigger input block showing the signal flow from ETR pin to CK_PSC.

For example, to configure the upcounter to count each 2 rising edges on ETR, use the following procedure:

  1. 1. As no filter is needed in this example, write ETF[3:0] = 0000 in the TIMx_SMCR register.
  2. 2. Set the prescaler by writing ETPS[1:0] = 01 in the TIMx_SMCR register
  3. 3. Select rising edge detection on the ETR pin by writing ETP = 0 in the TIMx_SMCR register
  4. 4. Enable external clock mode 2 by writing ECE = 1 in the TIMx_SMCR register.
  5. 5. Enable the counter by writing CEN = 1 in the TIMx_CR1 register.

The counter counts once each 2 ETR rising edges.

The delay between the rising edge on ETR and the actual clock of the counter is due to the resynchronization circuit on the ETRP signal.

Figure 111. Control circuit in external clock mode 2

Timing diagram for external clock mode 2 showing the relationship between fCK_INT, CNT_EN, ETR, ETRP, ETRF, and the counter register.

The diagram illustrates the timing of various signals in external clock mode 2. It shows the internal clock \(f_{CK\_INT}\), the counter enable signal CNT_EN, the external trigger input ETR, the resynchronized trigger signal ETRP, the filtered trigger signal ETRF, and the counter clock signal. The counter clock is derived from \(f_{CK\_INT}\) and is prescaled (CK_INT = CK_PSC). The counter register is shown with three states: 34, 35, and 36. The counter increments on the rising edge of ETRF, which occurs after a resynchronization delay from the rising edge of ETR. The counter clock signal is a pulse that occurs on the rising edge of ETRF.

MS33111V2

Timing diagram for external clock mode 2 showing the relationship between fCK_INT, CNT_EN, ETR, ETRP, ETRF, and the counter register.

17.3.5 Capture/compare channels

Each Capture/Compare channel is built around a capture/compare register (including a shadow register), a input stage for capture (with digital filter, multiplexing and prescaler) and an output stage (with comparator and output control).

Figure 112 to Figure 115 give an overview of one Capture/Compare channel.

The input stage samples the corresponding TIx input to generate a filtered signal TIxF. Then, an edge detector with polarity selection generates a signal (TIxFPx) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).

Figure 112. Capture/compare channel (example: channel 1 input stage)

Figure 112. Capture/compare channel (example: channel 1 input stage)
Figure 112. Capture/compare channel (example: channel 1 input stage)

MS33115V1

The output stage generates an intermediate waveform that is then used for reference: OCxRef (active high). The polarity acts at the end of the chain.

Figure 113. Capture/compare channel 1 main circuit

Figure 113. Capture/compare channel 1 main circuit
Figure 113. Capture/compare channel 1 main circuit

MS31089V3

Figure 114. Output stage of capture/compare channel (channel 1 to 3)

Figure 114: Output stage of capture/compare channel (channel 1 to 3) block diagram showing inputs ETRF, CNT>CCR1, CNT=CCR1, OCxREF(1), OC5REF into Output mode controller and Output selector, routing to master mode controller, Dead-time generator, multiplexers controlled by TIM1_CCER/TIM1_BDTR, and Output enable circuits driving OC1 and OC1N pins.

MS35909V1

Figure 114: Output stage of capture/compare channel (channel 1 to 3) block diagram showing inputs ETRF, CNT>CCR1, CNT=CCR1, OCxREF(1), OC5REF into Output mode controller and Output selector, routing to master mode controller, Dead-time generator, multiplexers controlled by TIM1_CCER/TIM1_BDTR, and Output enable circuits driving OC1 and OC1N pins.

Figure 115. Output stage of capture/compare channel (channel 4)

Figure 115: Output stage of capture/compare channel (channel 4) block diagram showing ETR, CNT>CCR4, CNT>CCR4 into Output mode controller, routing OC4REF to master mode controller, polarity multiplexer controlled by CC4P, and Output enable circuit driving OC4 pin, controlled by TIM1_CCER, TIM1_BDTR, and TIM1_CR2.

MS37370V1

Figure 115: Output stage of capture/compare channel (channel 4) block diagram showing ETR, CNT>CCR4, CNT>CCR4 into Output mode controller, routing OC4REF to master mode controller, polarity multiplexer controlled by CC4P, and Output enable circuit driving OC4 pin, controlled by TIM1_CCER, TIM1_BDTR, and TIM1_CR2.

The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.

In capture mode, captures are actually done in the shadow register, which is copied into the preload register.

In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.

17.3.6 Input capture mode

In Input capture mode, the Capture/Compare registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCxIF flag was already high, then the over-capture flag CCxOF (TIMx_SR register) is set. CCxIF can be cleared by software by writing it to '0' or by reading the captured data stored in the TIMx_CCRx register. CCxOF is cleared when written to '0'.

The following example shows how to capture the counter value in TIMx_CCR1 when TI1 input rises. To do this, use the following procedure:

When an input capture occurs:

In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which could happen after reading the flag and before reading the data.

Note: IC interrupt and/or DMA requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.

17.3.7 PWM input mode

This mode is a particular case of input capture mode. The procedure is the same except:

For example, user can measure the period (in TIMx_CCR1 register) and the duty cycle (in TIMx_CCR2 register) of the PWM applied on TI1 using the following procedure (depending on CK_INT frequency and prescaler value):

Figure 116. PWM input mode timing

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, and TIMx_CCR1/CCR2 registers. The diagram illustrates three capture events: IC1 capture (reset counter), IC2 capture (pulse width measurement), and IC1 capture period measurement. The counter (TIMx_CNT) increments from 0004 to 0000, then 0001, 0002, 0003, 0004, and back to 0000. TIMx_CCR1 is set to 0004 and TIMx_CCR2 is set to 0002. Arrows indicate the capture events on the TI1 signal edges.

The diagram shows the timing relationship between the TI1 input signal, the TIMx_CNT counter, and the TIMx_CCR1 and TIMx_CCR2 registers. The TI1 signal is a PWM waveform. The TIMx_CNT counter increments from 0004 to 0000, then 0001, 0002, 0003, 0004, and back to 0000. The TIMx_CCR1 register is set to 0004 and the TIMx_CCR2 register is set to 0002. Three capture events are shown: IC1 capture (reset counter) at the first rising edge of TI1, IC2 capture (pulse width measurement) at the first falling edge of TI1, and IC1 capture period measurement at the second rising edge of TI1.

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, and TIMx_CCR1/CCR2 registers. The diagram illustrates three capture events: IC1 capture (reset counter), IC2 capture (pulse width measurement), and IC1 capture period measurement. The counter (TIMx_CNT) increments from 0004 to 0000, then 0001, 0002, 0003, 0004, and back to 0000. TIMx_CCR1 is set to 0004 and TIMx_CCR2 is set to 0002. Arrows indicate the capture events on the TI1 signal edges.

17.3.8 Forced output mode

In output mode (CCxS bits = 00 in the TIMx_CCMRx register), each output compare signal (OCxREF and then OCx/OCxN) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.

To force an output compare signal (OCXREF/OCx) to its active level, the user just needs to write 101 in the OCxM bits in the corresponding TIMx_CCMRx register. Thus OCXREF is

forced high (OCxREF is always active high) and OCx get opposite value to CCxP polarity bit.

For example: CCxP=0 (OCx active high) => OCx is forced to high level.

The OCxREF signal can be forced low by writing the OCxM bits to 100 in the TIMx_CCMRx register.

Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt and DMA requests can be sent accordingly. This is described in the output compare mode section below.

17.3.9 Output compare mode

This function is used to control an output waveform or indicating when a period of time has elapsed.

When a match is found between the capture/compare register and the counter, the output compare function:

The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.

In output compare mode, the update event UEV has no effect on OCxREF and OCx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One Pulse mode).

Procedure:

  1. 1. Select the counter clock (internal, external, prescaler).
  2. 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
  3. 3. Set the CCxIE bit if an interrupt request is to be generated.
  4. 4. Select the output mode. For example:
    • – Write OCxM = 011 to toggle OCx output pin when CNT matches CCRx
    • – Write OCxPE = 0 to disable preload register
    • – Write CCxP = 0 to select active high polarity
    • – Write CCxE = 1 to enable the output
  5. 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.

The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE='0', else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 117.

Figure 117. Output compare mode, toggle on OC1

Timing diagram for output compare mode showing TIM1_CNT, TIM1_CCR1, and OC1REF=OC1 signals. It illustrates a match detection event when TIM1_CNT reaches the value in TIM1_CCR1, resulting in a toggle of the OC1REF signal.

The diagram illustrates the operation of output compare mode for channel 1 (OC1) in toggle mode. It shows three signals over time:

Key events shown:

MS31092V2

Timing diagram for output compare mode showing TIM1_CNT, TIM1_CCR1, and OC1REF=OC1 signals. It illustrates a match detection event when TIM1_CNT reaches the value in TIM1_CCR1, resulting in a toggle of the OC1REF signal.

17.3.10 PWM mode

Pulse Width Modulation mode allows generating a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.

The PWM mode can be selected independently on each channel (one PWM per OCx output) by writing ‘110’ (PWM mode 1) or ‘111’ (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. The corresponding preload register must be enabled by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the auto-reload preload register (in upcounting or center-aligned modes) by setting the ARPE bit in the TIMx_CR1 register.

As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, the user must initialize all the registers by setting the UG bit in the TIMx_EGR register.

OCx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. OCx output is enabled by a combination of the CCxE, CCxNE, MOE, OSSI and OSSR bits (TIMx_CCER and TIMx_BDTR registers). Refer to the TIMx_CCER register description for more details.

In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CCRx ≤ TIMx_CNT or TIMx_CNT ≤ TIMx_CCRx (depending on the direction of the counter).

The timer is able to generate PWM in edge-aligned mode or center-aligned mode depending on the CMS bits in the TIMx_CR1 register.

PWM edge-aligned mode

Upcounting is active when the DIR bit in the TIMx_CR1 register is low. Refer to Upcounting mode.

In the following example, we consider PWM mode 1. The reference PWM signal OCxREF is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the

compare value in TIMx_CCRx is greater than the auto-reload value (in TIMx_ARR) then OCxREF is held at '1'. If the compare value is 0 then OCxRef is held at '0'.

Figure 118 shows some edge-aligned PWM waveforms in an example where TIMx_ARR=8.

Figure 118. Edge-aligned PWM waveforms (ARR=8)

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register counting from 0 to 8 and then repeating. It illustrates four cases for CCRx: CCRx=4, CCRx=8, CCRx>8, and CCRx=0. For each case, the OCXREF and CCxIF signals are shown. Vertical dashed lines indicate the start of each counter cycle.

The diagram illustrates edge-aligned PWM waveforms for a timer with an auto-reload value (ARR) of 8. The Counter register counts from 0 to 8, and the cycle repeats. Four cases are shown for the Compare Register (CCRx):

MS31093V1

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register counting from 0 to 8 and then repeating. It illustrates four cases for CCRx: CCRx=4, CCRx=8, CCRx>8, and CCRx=0. For each case, the OCXREF and CCxIF signals are shown. Vertical dashed lines indicate the start of each counter cycle.

Downcounting is active when DIR bit in TIMx_CR1 register is high. Refer to

Downcounting mode

In PWM mode 1, the reference signal OCxRef is low as long as

TIMx_CNT > TIMx_CCRx else it becomes high. If the compare value in TIMx_CCRx is greater than the auto-reload value in TIMx_ARR, then OCxREF is held at '1'. 0% PWM is not possible in this mode.

PWM center-aligned mode

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are different from '00' (all the remaining configurations having the same effect on the OCxRef/OCx signals). The compare flag is set when the counter counts up, when it counts down or both when it counts up and down depending on the CMS bits configuration. The direction bit (DIR) in the

TIMx_CR1 register is updated by hardware and must not be changed by software. Refer to Center-aligned mode (up/down counting).

Figure 119 shows some center-aligned PWM waveforms in an example where:

Figure 119. Center-aligned PWM waveforms (ARR=8)

Timing diagram for center-aligned PWM waveforms with ARR=8. It shows the counter register counting up from 0 to 8 and then down from 7 to 0. Three cases are shown: CCRx=4, CCRx=7, and CCRx>8. For each, the OCxREF signal is high from counter value 0 to CCRx and low from CCRx to 8. The CCxIF flag is set at the start and end of the high period, with timing relative to the counter reaching 8 depending on the CMS setting (01, 10, or 11).

The diagram illustrates the timing of center-aligned PWM waveforms for a timer with an auto-reload register (ARR) value of 8. The counter register counts up from 0 to 8 and then counts down from 7 to 0. Three cases are shown based on the compare register value (CCRx):

ai14681b

Timing diagram for center-aligned PWM waveforms with ARR=8. It shows the counter register counting up from 0 to 8 and then down from 7 to 0. Three cases are shown: CCRx=4, CCRx=7, and CCRx>8. For each, the OCxREF signal is high from counter value 0 to CCRx and low from CCRx to 8. The CCxIF flag is set at the start and end of the high period, with timing relative to the counter reaching 8 depending on the CMS setting (01, 10, or 11).

Hints on using center-aligned mode:

17.3.11 Complementary outputs and dead-time insertion

The advanced-control timers (TIM1 and TIM8) can output two complementary signals and manage the switching-off and the switching-on instants of the outputs.

This time is generally known as dead-time and it has to be adjusted depending on the devices connected to the outputs and their characteristics (intrinsic delays of level-shifters, delays due to power switches...)

User can select the polarity of the outputs (main output OCx or complementary OCxN) independently for each output. This is done by writing to the CCxP and CCxNP bits in the TIMx_CCER register.

The complementary signals OCx and OCxN are activated by a combination of several control bits: the CCxE and CCxNE bits in the TIMx_CCER register and the MOE, OISx, OISxN, OSSI and OSSR bits in the TIMx_BDTR and TIMx_CR2 registers. Refer to Table 95 for more details. In particular, the dead-time is activated when switching to the IDLE state (MOE falling down to 0).

Dead-time insertion is enabled by setting both CCxE and CCxNE bits, and the MOE bit if the break circuit is present. DTG[7:0] bits of the TIMx_BDTR register are used to control the dead-time generation for all channels. From a reference waveform OCxREF, it generates 2 outputs OCx and OCxN. If OCx and OCxN are active high:

If the delay is greater than the width of the active output (OCx or OCxN) then the corresponding pulse is not generated.

The following figures show the relationships between the output signals of the dead-time generator and the reference signal OCxREF. (we suppose CCxP=0, CCxNP=0, MOE=1, CCxE=1 and CCxNE=1 in these examples)

Figure 120. Complementary output with dead-time insertion

Timing diagram for complementary output with dead-time insertion. It shows three signals: OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay on both rising and falling edges. OCxN is the complement of OCx, also with a delay on both edges. The delay is indicated by horizontal arrows between the transitions of OCxREF and the corresponding transitions of OCx and OCxN.

MS31095V1

Timing diagram for complementary output with dead-time insertion. It shows three signals: OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay on both rising and falling edges. OCxN is the complement of OCx, also with a delay on both edges. The delay is indicated by horizontal arrows between the transitions of OCxREF and the corresponding transitions of OCx and OCxN.

Figure 121. Dead-time waveforms with delay greater than the negative pulse

Timing diagram for dead-time waveforms with delay greater than the negative pulse. It shows OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay. OCxN is low when OCxREF is high and high when OCxREF is low, but with a delay on the rising edge of OCxREF. The delay is indicated by a horizontal arrow between the falling edge of OCxREF and the rising edge of OCxN.

MS31096V1

Timing diagram for dead-time waveforms with delay greater than the negative pulse. It shows OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay. OCxN is low when OCxREF is high and high when OCxREF is low, but with a delay on the rising edge of OCxREF. The delay is indicated by a horizontal arrow between the falling edge of OCxREF and the rising edge of OCxN.

Figure 122. Dead-time waveforms with delay greater than the positive pulse

Timing diagram for dead-time waveforms with delay greater than the positive pulse. It shows OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay. OCxN is low when OCxREF is high and high when OCxREF is low, but with a delay on the falling edge of OCxREF. The delay is indicated by a horizontal arrow between the rising edge of OCxREF and the falling edge of OCxN.

MS31097V1

Timing diagram for dead-time waveforms with delay greater than the positive pulse. It shows OCxREF, OCx, and OCxN. OCxREF is a square wave. OCx follows OCxREF with a delay. OCxN is low when OCxREF is high and high when OCxREF is low, but with a delay on the falling edge of OCxREF. The delay is indicated by a horizontal arrow between the rising edge of OCxREF and the falling edge of OCxN.

The dead-time delay is the same for each of the channels and is programmable with the DTG bits in the TIMx_BDTR register. Refer to Section 17.4.18 for delay calculation.

Re-directing OCxREF to OCx or OCxN

In output mode (forced, output compare or PWM), OCxREF can be re-directed to the OCx output or to OCxN output by configuring the CCxE and CCxNE bits in the TIMx_CCER register.

This allows the user to send a specific waveform (such as PWM or static active level) on one output while the complementary remains at its inactive level. Other possibilities are to have both outputs at inactive level or both outputs active and complementary with

dead-time.

Note: When only OCxN is enabled (CCxE=0, CCxNE=1), it is not complemented and becomes active as soon as OCxREF is high. For example, if CCxNP=0 then OCxN=OCxRef. On the other hand, when both OCx and OCxN are enabled (CCxE=CCxNE=1) OCx becomes active when OCxREF is high whereas OCxN is complemented and becomes active when OCxREF is low.

17.3.12 Using the break function

When using the break function, the output enable signals and inactive levels are modified according to additional control bits (MOE, OSSI and OSSR bits in the TIMx_BDTR register, OISx and OISxN bits in the TIMx_CR2 register). In any case, the OCx and OCxN outputs cannot be set both to active level at a given time. Refer to Table 95 for more details.

The break source can be either the break input pin or a clock failure event, generated by the Clock Security System (CSS), from the Reset Clock Controller. For further information on the Clock Security System, refer to Section 7.2.7: Clock security system (CSS).

When exiting from reset, the break circuit is disabled and the MOE bit is low. User can enable the break function by setting the BKE bit in the TIMx_BDTR register. The break input polarity can be selected by configuring the BKP bit in the same register. BKE and BKP can be modified at the same time. When the BKE and BKP bits are written, a delay of 1 APB clock cycle is applied before the writing is effective. Consequently, it is necessary to wait 1 APB clock period to correctly read back the bit after the write operation.

Because MOE falling edge can be asynchronous, a resynchronization circuit has been inserted between the actual signal (acting on the outputs) and the synchronous control bit (accessed in the TIMx_BDTR register). It results in some delays between the asynchronous and the synchronous signals. In particular, if MOE is written to 1 whereas it was low, a delay (dummy instruction) must be inserted before reading it correctly. This is because the user writes an asynchronous signal, but reads a synchronous signal.

When a break occurs (selected level on the break input):

Note: The break inputs is acting on level. Thus, the MOE cannot be set while the break input is active (neither automatically nor by software). In the meantime, the status flag BIF cannot be cleared.

The break can be generated by the BRK input which has a programmable polarity and an enable bit BKE in the TIMx_BDTR register.

There are two solutions to generate a break:

In addition to the break input and the output management, a write protection has been implemented inside the break circuit to safeguard the application. It allows freezing the configuration of several parameters (dead-time duration, OCx/OCxN polarities and state when disabled, OCxM configurations, break enable and polarity). The user can choose from three levels of protection selected by the LOCK bits in the TIMx_BDTR register. Refer to Section 17.4.18. The LOCK bits can be written only once after an MCU reset.

Figure 123 shows an example of behavior of the outputs in response to a break.

Figure 123. Output behavior in response to a break

Timing diagram showing output behavior of OCxREF, OCx, and OCxN in response to a BREAK (MOE low) signal. The diagram illustrates various combinations of CCxP, OISx, and CCxNE/CCxNP settings and their resulting output states and delays.

The diagram illustrates the output behavior of OCxREF, OCx, and OCxN in response to a BREAK (MOE low) signal. The signals are shown as waveforms over time, with vertical dashed lines indicating the timing of the break and the subsequent output changes. The diagram is divided into several sections, each representing a different combination of configuration parameters (CCxP, OISx, CCxNE, CCxNP).

Signals and Parameters:

Timing and Delays:

Sections and Configurations:

  1. OCxREF: The output changes immediately after the break signal.
  2. OCx: (OCxN not implemented, CCxP=0, OISx=1)
  3. OCx: (OCxN not implemented, CCxP=0, OISx=0)
  4. OCx: (OCxN not implemented, CCxP=1, OISx=1)
  5. OCx: (OCxN not implemented, CCxP=1, OISx=0)
  6. OCx: (CCxE=1, CCxP=0, OISx=0, CCxNE=1, CCxNP=0, OISxN=1)
  7. OCx: (CCxE=1, CCxP=0, OISx=1, CCxNE=1, CCxNP=1, OISxN=1)
  8. OCx: (CCxE=1, CCxP=0, OISx=0, CCxNE=0, CCxNP=0, OISxN=1)
  9. OCx: (CCxE=1, CCxP=0, OISx=1, CCxNE=0, CCxNP=0, OISxN=0)
  10. OCx: (CCxE=1, CCxP=0, CCxNE=0, CCxNP=0, OISx=OISxN=0 or OISx=OISxN=1)

MS31098V1

Timing diagram showing output behavior of OCxREF, OCx, and OCxN in response to a BREAK (MOE low) signal. The diagram illustrates various combinations of CCxP, OISx, and CCxNE/CCxNP settings and their resulting output states and delays.

17.3.13 Clearing the OCxREF signal on an external event

The OCxREF signal for a given channel can be driven Low by applying a High level to the ETRF input (OCxCE enable bit of the corresponding TIMx_CCMRx register set to '1'). The OCxREF signal remains Low until the next update event, UEV, occurs.

This function can only be used in output compare and PWM modes, and does not work in forced mode.

For example, the ETR signal can be connected to the output of a comparator to be used for current handling. In this case, the ETR must be configured as follow:

Figure 124 shows the behavior of the OCxREF signal when the ETRF Input becomes High, for both values of the enable bit OCxCE. In this example, the timer TIMx is programmed in PWM mode.

Figure 124. Clearing TIMx OCxREF

Timing diagram showing Counter (CNT), ETRF, and OCxREF signals for OCxCE = '0' and OCxCE = '1'.
Timing diagram showing Counter (CNT), ETRF, and OCxREF signals for OCxCE = '0' and OCxCE = '1'.

Note: In case of a PWM with a 100% duty cycle (if CCRx>ARR), then OCxREF is enabled again at the next counter overflow.

17.3.14 6-step PWM generation

When complementary outputs are used on a channel, preload bits are available on the OCxM, CCxE and CCxNE bits. The preload bits are transferred to the shadow bits at the COM commutation event. The user can thus program in advance the configuration for the next step and change the configuration of all the channels at the same time. COM can be generated by software by setting the COM bit in the TIMx_EGR register or by hardware (on TRGI rising edge).

A flag is set when the COM event occurs (COMIF bit in the TIMx_SR register), which can generate an interrupt (if the COMIE bit is set in the TIMx_DIER register) or a DMA request (if the COMDE bit is set in the TIMx_DIER register).

Figure 125 describes the behavior of the OCx and OCxN outputs when a COM event occurs, in 3 different examples of programmed configurations.

Figure 125. 6-step generation, COM example (OSSR=1)

Timing diagram for 6-step generation with COM event, showing counter (CNT), OCxREF, COM event, and three examples of OCx and OCxN outputs.

The diagram illustrates the behavior of the OCx and OCxN outputs during a COM event in a 6-step generation sequence. It shows the counter (CNT) ramping up and resetting, the OCxREF signal, the COM event trigger, and the resulting OCx and OCxN outputs for three different examples.

Example 1: Initial state: CCxE=1, CCxNE=0, OCxM=100 (forced inactive). Action: write OCxM to 100. Final state: CCxE=1, CCxNE=0, OCxM=100.

Example 2: Initial state: CCxE=1, CCxNE=0, OCxM=100 (forced inactive). Action: Write CCxNE to 1 and OCxM to 101. Final state: CCxE=0, CCxNE=1, OCxM=101.

Example 3: Initial state: CCxE=1, CCxNE=0, OCxM=100 (forced inactive). Action: write CCxNE to 0 and OCxM to 100. Final state: CCxE=1, CCxNE=0, OCxM=100.

ai14910

Timing diagram for 6-step generation with COM event, showing counter (CNT), OCxREF, COM event, and three examples of OCx and OCxN outputs.

17.3.15 One-pulse mode

One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.

Starting the counter can be controlled through the slave mode controller. Generating the waveform can be done in output compare mode or PWM mode. Select One-pulse mode by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.

A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting (when the timer is waiting for the trigger), the configuration must be:

Figure 126. Example of one pulse mode

Timing diagram for One-pulse mode showing TI2 trigger, OC1REF, OC1 output, and Counter (TIM1_CCR1) progression over time. The counter starts at 0, counts up to TIM1_ARR, and then stops. A positive edge on TI2 triggers the counter after a delay t_DELAY, and the output OC1 is high for a duration t_PULSE.

The diagram illustrates the operation of One-pulse mode. It shows four signals over time (t):

MS31099V2

Timing diagram for One-pulse mode showing TI2 trigger, OC1REF, OC1 output, and Counter (TIM1_CCR1) progression over time. The counter starts at 0, counts up to TIM1_ARR, and then stops. A positive edge on TI2 triggers the counter after a delay t_DELAY, and the output OC1 is high for a duration t_PULSE.

For example the user may want to generate a positive pulse on OC1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\) as soon as a positive edge is detected on the TI2 input pin.

Let's use TI2FP2 as trigger 1:

The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).

In our example, the DIR and CMS bits in the TIMx_CR1 register should be low.

The user only wants one pulse (Single mode), so '1' must be written in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over from the auto-reload value back to 0). When OPM bit in the TIMx_CR1 register is set to '0', so the Repetitive mode is selected.

Particular case: OCx fast enable:

In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{\text{DELAY}}\) min we can get.

If the user wants to output a waveform with the minimum delay, the OCxFE bit in the TIMx_CCMRx register must be set. Then OCxRef (and OCx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.

17.3.16 Encoder interface mode

To select Encoder Interface mode write SMS='001' in the TIMx_SMCR register if the counter is counting on TI2 edges only, SMS='010' if it is counting on TI1 edges only and SMS='011' if it is counting on both TI1 and TI2 edges.

Select the TI1 and TI2 polarity by programming the CC1P and CC2P bits in the TIMx_CCER register. When needed, the user can program the input filter as well. CC1NP and CC2NP must be kept low.

The two inputs TI1 and TI2 are used to interface to an incremental encoder. Refer to Table 93. The counter is clocked by each valid transition on TI1FP1 or TI2FP2 (TI1 and TI2 after input filter and polarity selection, TI1FP1=TI1 if not filtered and not inverted, TI2FP2=TI2 if not filtered and not inverted) assuming that it is enabled (CEN bit in TIMx_CR1 register written to '1'). The sequence of transitions of the two inputs is evaluated and generates count pulses as well as the direction signal. Depending on the sequence the counter counts up or down, the DIR bit in the TIMx_CR1 register is modified by hardware accordingly. The DIR bit is calculated at each transition on any input (TI1 or TI2), whatever the counter is counting on TI1 only, TI2 only or both TI1 and TI2.

Encoder interface mode acts simply as an external clock with direction selection. This means that the counter just counts continuously between 0 and the auto-reload value in the

TIMx_ARR register (0 to ARR or ARR down to 0 depending on the direction). So user must configure TIMx_ARR before starting. In the same way, the capture, compare, prescaler, repetition counter, trigger output features continue to work as normal. Encoder mode and External clock mode 2 are not compatible and must not be selected together.

In this mode, the counter is modified automatically following the speed and the direction of the incremental encoder and its content, therefore, always represents the encoder's position. The count direction correspond to the rotation direction of the connected sensor.

Table 93 summarizes the possible combinations, assuming TI1 and TI2 do not switch at the same time.

Table 93. Counting direction versus encoder signals

Active edgeLevel on opposite signal
(TI1FP1 for TI2, TI2FP2 for TI1)
TI1FP1 signalTI2FP2 signal
RisingFallingRisingFalling
Counting on TI1 onlyHighDownUpNo CountNo Count
LowUpDownNo CountNo Count
Counting on TI2 onlyHighNo CountNo CountUpDown
LowNo CountNo CountDownUp
Counting on TI1 and TI2HighDownUpUpDown
LowUpDownDownUp

An external incremental encoder can be connected directly to the MCU without external interface logic. However, comparators are normally be used to convert the encoder's differential outputs to digital signals. This greatly increases noise immunity. The third encoder output which indicate the mechanical zero position, may be connected to an external interrupt input and trigger a counter reset.

Figure 127 gives an example of counter operation, showing count signal generation and direction control. It also shows how input jitter is compensated where both edges are selected. This might occur if the sensor is positioned near to one of the switching points. For this example we assume that the configuration is the following:

Figure 127. Example of counter operation in encoder interface mode

Timing diagram for Figure 127 showing TI1, TI2, and Counter waveforms. TI1 and TI2 are square waves. The Counter increments ('up') during the first 'forward' and last 'forward' phases, and decrements ('down') during the 'backward' phase. 'Jitter' phases show irregular pulses on TI1 and TI2.

Figure 127 illustrates the counter operation in encoder interface mode. The diagram shows three waveforms: TI1, TI2, and the Counter. TI1 and TI2 are square waves representing the encoder signals. The Counter increments ('up') during the 'forward' phases and decrements ('down') during the 'backward' phase. The 'jitter' phases show irregular pulses on TI1 and TI2, indicating signal noise or interference. The Counter value is shown as a staircase waveform, reflecting the cumulative count of encoder events.

Timing diagram for Figure 127 showing TI1, TI2, and Counter waveforms. TI1 and TI2 are square waves. The Counter increments ('up') during the first 'forward' and last 'forward' phases, and decrements ('down') during the 'backward' phase. 'Jitter' phases show irregular pulses on TI1 and TI2.

Figure 128 gives an example of counter behavior when TI1FP1 polarity is inverted (same configuration as above except CC1P='1').

Figure 128. Example of encoder interface mode with TI1FP1 polarity inverted

Timing diagram for Figure 128 showing TI1, TI2, and Counter waveforms with TI1FP1 polarity inverted. The Counter decrements ('down') during the first 'forward' phase and increments ('up') during the 'backward' phase, which is the opposite of Figure 127.

Figure 128 illustrates the counter operation in encoder interface mode with TI1FP1 polarity inverted. The diagram shows three waveforms: TI1, TI2, and the Counter. TI1 and TI2 are square waves representing the encoder signals. The Counter decrements ('down') during the first 'forward' phase and increments ('up') during the 'backward' phase. The 'jitter' phases show irregular pulses on TI1 and TI2, indicating signal noise or interference. The Counter value is shown as a staircase waveform, reflecting the cumulative count of encoder events.

Timing diagram for Figure 128 showing TI1, TI2, and Counter waveforms with TI1FP1 polarity inverted. The Counter decrements ('down') during the first 'forward' phase and increments ('up') during the 'backward' phase, which is the opposite of Figure 127.

The timer, when configured in Encoder Interface mode provides information on the sensor's current position. The user can obtain dynamic information (speed, acceleration, deceleration) by measuring the period between two encoder events using a second timer configured in capture mode. The output of the encoder which indicates the mechanical zero can be used for this purpose. Depending on the time between two events, the counter can also be read at regular times. This can be done by latching the counter value into a third input capture register if available (then the capture signal must be periodic and can be generated by another timer). When available, it is also possible to read its value through a DMA request generated by a real-time clock.

17.3.17 Timer input XOR function

The TI1S bit in the TIMx_CR2 register, allows the input filter of channel 1 to be connected to the output of a XOR gate, combining the three input pins TIMx_CH1, TIMx_CH2 and TIMx_CH3.

The XOR output can be used with all the timer input functions such as trigger or input capture. An example of this feature used to interface Hall sensors is given in Section 17.3.18.

17.3.18 Interfacing with Hall sensors

This is done using the advanced-control timers (TIM1 or TIM8) to generate PWM signals to drive the motor and another timer TIMx (TIM2, TIM3, TIM4 or TIM5) referred to as “interfacing timer” in Figure 129. The “interfacing timer” captures the 3 timer input pins (TIMx_CH1, TIMx_CH2, and TIMx_CH3) connected through a XOR to the TI1 input channel (selected by setting the TI1S bit in the TIMx_CR2 register).

The slave mode controller is configured in reset mode; the slave input is TI1F_ED. Thus, each time one of the 3 inputs toggles, the counter restarts counting from 0. This creates a time base triggered by any change on the Hall inputs.

On the “interfacing timer”, capture/compare channel 1 is configured in capture mode, capture signal is TRC (see Figure 112). The captured value, which corresponds to the time elapsed between 2 changes on the inputs, gives information about motor speed.

The “interfacing timer” can be used in output mode to generate a pulse which changes the configuration of the channels of the advanced-control timer (TIM1 or TIM8) (by triggering a COM event). The TIM1 timer is used to generate PWM signals to drive the motor. To do this, the interfacing timer channel must be programmed so that a positive pulse is generated after a programmed delay (in output compare or PWM mode). This pulse is sent to the advanced-control timer (TIM1 or TIM8) through the TRGO output.

Example: the user wants to change the PWM configuration of the advanced-control timer TIM1 after a programmed delay each time a change occurs on the Hall inputs connected to one of the TIMx timers.

In the advanced-control timer TIM1, the right ITR input must be selected as trigger input, the timer is programmed to generate PWM signals, the capture/compare control signals are preloaded (CCPC=1 in the TIMx_CR2 register) and the COM event is controlled by the trigger input (CCUS=1 in the TIMx_CR2 register). The PWM control bits (CCxE, OCxM) are written after a COM event for the next step (this can be done in an interrupt subroutine generated by the rising edge of OC2REF).

Figure 129 describes this example.

Figure 129. Example of Hall sensor interface

Timing diagram for Hall sensor interface showing signals TIH1, TIH2, TIH3, Counter (CNT), CCR1, TRGO=OC2REF, COM, OC1, OC1N, OC2, OC2N, OC3, and OC3N. It includes a label 'Write CCxE, CCxNE and OCxM for next step' and a reference 'ai17335b'.

The diagram illustrates the interaction between an interfacing timer and advanced-control timers for a Hall sensor interface. It is divided into two main sections: 'Interfacing timer' and 'Advanced-control timers'.

Interfacing timer signals:

Advanced-control timers signals:

Vertical dashed lines align the signals across the different timer sections. At the bottom, arrows point to specific time intervals with the instruction: "Write CCxE, CCxNE and OCxM for next step". The reference code "ai17335b" is located in the bottom right corner of the diagram area.

Timing diagram for Hall sensor interface showing signals TIH1, TIH2, TIH3, Counter (CNT), CCR1, TRGO=OC2REF, COM, OC1, OC1N, OC2, OC2N, OC3, and OC3N. It includes a label 'Write CCxE, CCxNE and OCxM for next step' and a reference 'ai17335b'.

17.3.19 TIMx and external trigger synchronization

The TIMx timer can be synchronized with an external trigger in several modes: Reset mode, Gated mode and Trigger mode.

Slave mode: Reset mode

The counter and its prescaler can be reinitialized in response to an event on a trigger input. Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated.

In the following example, the upcounter is cleared in response to a rising edge on TI1 input:

The counter starts counting on the internal clock, then behaves normally until TI1 rising edge. When TI1 rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request, or a DMA request can be sent if enabled (depending on the TIE and TDE bits in TIMx_DIER register).

The following figure shows this behavior when the auto-reload register TIMx_ARR=0x36. The delay between the rising edge on TI1 and the actual reset of the counter is due to the resynchronization circuit on TI1 input.

Figure 130. Control circuit in reset mode

Timing diagram showing TI1, UG, Counter clock, Counter register, and TIF signals. The counter register shows values 30-36 followed by 00-03, resetting to 00-03 after a TI1 rising edge.

The diagram illustrates the control circuit in reset mode. It shows five signals over time:

A vertical dashed line indicates the moment the counter is reset after the TI1 rising edge. The label 'MS31401V3' is present in the bottom right corner of the diagram area.

Timing diagram showing TI1, UG, Counter clock, Counter register, and TIF signals. The counter register shows values 30-36 followed by 00-03, resetting to 00-03 after a TI1 rising edge.

Slave mode: Gated mode

The counter can be enabled depending on the level of a selected input.

In the following example, the upcounter counts only when TI1 input is low:

The counter starts counting on the internal clock as long as TI1 is low and stops as soon as TI1 becomes high. The TIF flag in the TIMx_SR register is set both when the counter starts or stops.

The delay between the rising edge on TI1 and the actual stop of the counter is due to the resynchronization circuit on TI1 input.

Figure 131. Control circuit in gated mode

Timing diagram for Gated mode showing TI1, CNT_EN, Counter clock, Counter register, and TIF signals.

The diagram illustrates the control circuit in gated mode. It shows the following signals over time:

Arrows indicate the relationship between the signals: the counter clock is gated by CNT_EN, and the TIF flag is set when the counter clock starts or stops. A label "Write TIF=0" points to the TIF signal, indicating that the flag can be cleared by writing 0 to it.

MS31402V3

Timing diagram for Gated mode showing TI1, CNT_EN, Counter clock, Counter register, and TIF signals.

Slave mode: Trigger mode

The counter can start in response to an event on a selected input.

In the following example, the upcounter starts in response to a rising edge on TI2 input:

When a rising edge occurs on TI2, the counter starts counting on the internal clock and the TIF flag is set.

The delay between the rising edge on TI2 and the actual start of the counter is due to the resynchronization circuit on TI2 input.

Figure 132. Control circuit in trigger mode

Timing diagram for Figure 132 showing the control circuit in trigger mode. The diagram includes five signals: TI2, CNT_EN, Counter clock = ck_cnt = ck_psc, Counter register, and TIF. TI2 is a square wave that goes high and then low. CNT_EN is a square wave that goes high after the falling edge of TI2. The Counter clock signal is a square wave that starts after the rising edge of CNT_EN. The Counter register shows a sequence of values: 34, 35, 36, 37, 38. The TIF signal is a square wave that goes high after the rising edge of CNT_EN. The diagram is labeled MS31403V2 in the bottom right corner.
Timing diagram for Figure 132 showing the control circuit in trigger mode. The diagram includes five signals: TI2, CNT_EN, Counter clock = ck_cnt = ck_psc, Counter register, and TIF. TI2 is a square wave that goes high and then low. CNT_EN is a square wave that goes high after the falling edge of TI2. The Counter clock signal is a square wave that starts after the rising edge of CNT_EN. The Counter register shows a sequence of values: 34, 35, 36, 37, 38. The TIF signal is a square wave that goes high after the rising edge of CNT_EN. The diagram is labeled MS31403V2 in the bottom right corner.

Slave mode: external clock mode 2 + trigger mode

The external clock mode 2 can be used in addition to another slave mode (except external clock mode 1 and encoder mode). In this case, the ETR signal is used as external clock input, and another input can be selected as trigger input (in reset mode, gated mode or trigger mode). It is recommended not to select ETR as TRGI through the TS bits of TIMx_SMCR register.

In the following example, the upcounter is incremented at each rising edge of the ETR signal as soon as a rising edge of TI1 occurs:

  1. 1. Configure the external trigger input circuit by programming the TIMx_SMCR register as follows:
    • – ETF = 0000: no filter
    • – ETPS = 00: prescaler disabled
    • – ETP = 0: detection of rising edges on ETR and ECE=1 to enable the external clock mode 2.
  2. 2. Configure the channel 1 as follows, to detect rising edges on TI1:
    • – IC1F=0000: no filter.
    • – The capture prescaler is not used for triggering and does not need to be configured.
    • – CC1S=01 in TIMx_CCMR1 register to select only the input capture source
    • – CC1P=0 and CC1NP='0' in TIMx_CCER register to validate the polarity (and detect rising edge only).
  3. 3. Configure the timer in trigger mode by writing SMS=110 in TIMx_SMCR register. Select TI1 as the input source by writing TS=101 in TIMx_SMCR register.

A rising edge on TI1 enables the counter and sets the TIF flag. The counter then counts on ETR rising edges.

The delay between the rising edge of the ETR signal and the actual reset of the counter is due to the resynchronization circuit on ETRP input.

Figure 133. Control circuit in external clock mode 2 + trigger mode

Timing diagram for Figure 133 showing the control circuit in external clock mode 2 + trigger mode. The diagram includes signals TI1, CEN/CNT_EN, ETR, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a high pulse that triggers CEN/CNT_EN to go high. ETR is a periodic square wave. The counter clock is a pulse train that starts when CEN/CNT_EN is high and ETR is high. The counter register shows values 34, 35, and 36 corresponding to the clock pulses. TIF is a low pulse that occurs when the counter register reaches 36.

The diagram illustrates the control circuit in external clock mode 2 + trigger mode. It shows the relationship between the TI1 signal, the CEN/CNT_EN signal, the ETR signal, the counter clock (CK_CNT = CK_PSC), the counter register, and the TIF signal. The counter register increments from 34 to 35 to 36 as the counter clock pulses occur. The TIF signal is a low pulse that occurs when the counter register reaches 36.

Timing diagram for Figure 133 showing the control circuit in external clock mode 2 + trigger mode. The diagram includes signals TI1, CEN/CNT_EN, ETR, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a high pulse that triggers CEN/CNT_EN to go high. ETR is a periodic square wave. The counter clock is a pulse train that starts when CEN/CNT_EN is high and ETR is high. The counter register shows values 34, 35, and 36 corresponding to the clock pulses. TIF is a low pulse that occurs when the counter register reaches 36.

17.3.20 Timer synchronization

The TIM timers are linked together internally for timer synchronization or chaining. Refer to Section 18.3.15: Timer synchronization for details.

Note: The clock of the slave timer must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

17.3.21 Debug mode

When the microcontroller enters debug mode (Cortex®-M4 with FPU core halted), the TIMx counter either continues to work normally or stops, depending on DBG_TIMx_STOP configuration bit in DBG module. For more details, refer to Section 38.16.2: Debug support for timers, watchdog, bxCAN and I2C.

For safety purposes, when the counter is stopped (DBG_TIMx_STOP = 1 in DBGMCU_APBx_FZ register), the outputs are disabled (as if the MOE bit was reset). The outputs can either be forced to an inactive state (OSSI bit = 1), or have their control taken over by the GPIO controller (OSSI bit = 0) to force them to Hi-Z.

17.4 TIM1 and TIM8 registers

Refer to Section 2.2 for a list of abbreviations used in register descriptions.

The peripheral registers must be written by half-words (16 bits) or words (32 bits). Read accesses can be done by bytes (8 bits), half-word (16 bits) or words (32 bits).

17.4.1 TIM1 and TIM8 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
ReservedCKD[1:0]ARPECMS[1:0]DIROPMURSUDISCEN
rwrwrwrwrwrwrwrwrwrw

Bits 15:10 Reserved, must be kept at reset value.

Bits 9:8 CKD[1:0]: Clock division

This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (\(t_{DTS}\)) used by the dead-time generators and the digital filters (ETR, TIx),

00: \(t_{DTS}=t_{CK\_INT}\)

01: \(t_{DTS}=2*t_{CK\_INT}\)

10: \(t_{DTS}=4*t_{CK\_INT}\)

11: Reserved, do not program this value

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered

1: TIMx_ARR register is buffered

Bits 6:5 CMS[1:0]: Center-aligned mode selection

00: Edge-aligned mode. The counter counts up or down depending on the direction bit (DIR).

01: Center-aligned mode 1. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set only when the counter is counting down.

10: Center-aligned mode 2. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set only when the counter is counting up.

11: Center-aligned mode 3. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set both when the counter is counting up or down.

Note: It is not allowed to switch from edge-aligned mode to center-aligned mode as long as the counter is enabled (CEN=1)

Bit 4 DIR: Direction

0: Counter used as upcounter

1: Counter used as downcounter

Note: This bit is read only when the timer is configured in Center-aligned mode or Encoder mode.

Bit 3 OPM: One pulse mode

0: Counter is not stopped at update event

1: Counter stops counting at the next update event (clearing the bit CEN)

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

0: Any of the following events generate an update interrupt or DMA request if enabled.

These events can be:

1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

0: UEV enabled. The Update (UEV) event is generated by one of the following events:

Buffered registers are then loaded with their preload values.

1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC, CCRx). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

Note: External clock, gated mode and encoder mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

17.4.2 TIM1 and TIM8 control register 2 (TIMx_CR2)

Address offset: 0x04

Reset value: 0x0000

1514131211109876543210
Res.OIS4OIS3NOIS3OIS2NOIS2OIS1NOIS1TI1SMMS[2:0]CCDSCCUSRes.CCPC
rwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 15 Reserved, must be kept at reset value.

Bit 14 OIS4: Output Idle state 4 (OC4 output)
refer to OIS1 bit

Bit 13 OIS3N: Output Idle state 3 (OC3N output)
refer to OIS1N bit

Bit 12 OIS3: Output Idle state 3 (OC3 output)
refer to OIS1 bit

Bit 11 OIS2N: Output Idle state 2 (OC2N output)
refer to OIS1N bit

Bit 10 OIS2: Output Idle state 2 (OC2 output)
refer to OIS1 bit

Bit 0 CCPC: Capture/compare preloaded control

0: CCxE, CCxNE and OCxM bits are not preloaded

1: CCxE, CCxNE and OCxM bits are preloaded, after having been written, they are updated only when a commutation event (COM) occurs (COMG bit set or rising edge detected on TRGI, depending on the CCUS bit).

Note: This bit acts only on channels that have a complementary output.

17.4.3 TIM1 and TIM8 slave mode control register (TIMx_SMCR)

Address offset: 0x08

Reset value: 0x0000

1514131211109876543210
ETPECEETPS[1:0]ETF[3:0]MSMTS[2:0]Res.SMS[2:0]
rwrwrwrwrwrwrwrwrwrwrwrwRes.rwrwrw

Bit 15 ETP: External trigger polarity

This bit selects whether ETR or \(\overline{ETR}\) is used for trigger operations

0: ETR is non-inverted, active at high level or rising edge.

1: ETR is inverted, active at low level or falling edge.

Bit 14 ECE: External clock enable

This bit enables External clock mode 2.

0: External clock mode 2 disabled

1: External clock mode 2 enabled. The counter is clocked by any active edge on the ETRF signal.

Note: 1: Setting the ECE bit has the same effect as selecting external clock mode 1 with TRGI connected to ETRF (SMS=111 and TS=111).

2: It is possible to simultaneously use external clock mode 2 with the following slave modes: reset mode, gated mode and trigger mode. Nevertheless, TRGI must not be connected to ETRF in this case (TS bits must not be 111).

3: If external clock mode 1 and external clock mode 2 are enabled at the same time, the external clock input is ETRF.

Bits 13:12 ETPS[1:0]: External trigger prescaler

External trigger signal ETRP frequency must be at most 1/4 of TIMxCLK frequency. A prescaler can be enabled to reduce ETRP frequency. It is useful when inputting fast external clocks.

00: Prescaler OFF

01: ETRP frequency divided by 2

10: ETRP frequency divided by 4

11: ETRP frequency divided by 8

Bits 11:8 ETF[3:0]: External trigger filter

This bit-field then defines the frequency used to sample ETRP signal and the length of the digital filter applied to ETRP. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, sampling is done at \(f_{DTS}\)

0001: \(f_{SAMPLING}=f_{CK\_INT}\), N=2

0010: \(f_{SAMPLING}=f_{CK\_INT}\), N=4

0011: \(f_{SAMPLING}=f_{CK\_INT}\), N=8

0100: \(f_{SAMPLING}=f_{DTS}/2\), N=6

0101: \(f_{SAMPLING}=f_{DTS}/2\), N=8

0110: \(f_{SAMPLING}=f_{DTS}/4\), N=6

0111: \(f_{SAMPLING}=f_{DTS}/4\), N=8

1000: \(f_{SAMPLING}=f_{DTS}/8\), N=6

1001: \(f_{SAMPLING}=f_{DTS}/8\), N=8

1010: \(f_{SAMPLING}=f_{DTS}/16\), N=5

1011: \(f_{SAMPLING}=f_{DTS}/16\), N=6

1100: \(f_{SAMPLING}=f_{DTS}/16\), N=8

1101: \(f_{SAMPLING}=f_{DTS}/32\), N=5

1110: \(f_{SAMPLING}=f_{DTS}/32\), N=6

1111: \(f_{SAMPLING}=f_{DTS}/32\), N=8

Bit 7 MSM: Master/slave mode

0: No action

1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect synchronization between the current timer and its slaves (through TRGO). It is useful if we want to synchronize several timers on a single external event.

Bits 6:4 TS[2:0]: Trigger selection

This bit-field selects the trigger input to be used to synchronize the counter.

000: Internal Trigger 0 (ITR0)

001: Internal Trigger 1 (ITR1)

010: Internal Trigger 2 (ITR2)

011: Internal Trigger 3 (ITR3)

100: TI1 Edge Detector (TI1F_ED)

101: Filtered Timer Input 1 (TI1FP1)

110: Filtered Timer Input 2 (TI2FP2)

111: External Trigger input (ETRF)

See Table 94 for more details on ITRx meaning for each Timer.

Note: These bits must be changed only when they are not used (e.g. when SMS=000) to avoid wrong edge detections at the transition.

Bit 3 Reserved, must be kept at reset value.

Bits 2:0 SMS: Slave mode selection

When external signals are selected the active edge of the trigger signal (TRGI) is linked to the polarity selected on the external input (see Input Control register and Control register description).

000: Slave mode disabled - if CEN = '1' then the prescaler is clocked directly by the internal clock.

001: Encoder mode 1 - Counter counts up/down on TI1FP1 edge depending on TI2FP2 level.

010: Encoder mode 2 - Counter counts up/down on TI2FP2 edge depending on TI1FP1 level.

011: Encoder mode 3 - Counter counts up/down on both TI1FP1 and TI2FP2 edges depending on the level of the other input.

100: Reset mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter and generates an update of the registers.

101: Gated mode - The counter clock is enabled when the trigger input (TRGI) is high. The counter stops (but is not reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.

110: Trigger mode - The counter starts at a rising edge of the trigger TRGI (but it is not reset). Only the start of the counter is controlled.

111: External Clock mode 1 - Rising edges of the selected trigger (TRGI) clock the counter.

Note: The gated mode must not be used if TI1F_ED is selected as the trigger input (TS='100'). Indeed, TI1F_ED outputs 1 pulse for each transition on TI1F, whereas the gated mode checks the level of the trigger signal.

The clock of the slave timer must be enabled prior to receiving events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Table 94. TIMx Internal trigger connection
Slave TIMITR0 (TS = 000)ITR1 (TS = 001)ITR2 (TS = 010)ITR3 (TS = 011)
TIM1TIM5_TRGOTIM2_TRGOTIM3_TRGOTIM4_TRGO
TIM8TIM1_TRGOTIM2_TRGOTIM4_TRGOTIM5_TRGO

17.4.4 TIM1 and TIM8 DMA/interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
Res.TDECOMDECC4DECC3DECC2DECC1DEUDEBIETIECOMIECC4IECC3IECC2IECC1IEUIE
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 15 Reserved, must be kept at reset value.

Bit 14 TDE: Trigger DMA request enable

0: Trigger DMA request disabled

1: Trigger DMA request enabled

Bit 13 COMDE: COM DMA request enable

0: COM DMA request disabled

1: COM DMA request enabled

17.4.5 TIM1 and TIM8 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
ReservedCC4OFCC3OFCC2OFCC1OFRes.BIFTIFCOMIFCC4IFCC3IFCC2IFCC1IFUIF
rc_w0rc_w0rc_w0rc_w0Res.rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0

Bits 15:13 Reserved, must be kept at reset value.

Bit 12 CC4OF: Capture/Compare 4 overcapture flag
refer to CC1OF description

Bit 11 CC3OF: Capture/Compare 3 overcapture flag
refer to CC1OF description

Bit 10 CC2OF: Capture/Compare 2 overcapture flag
refer to CC1OF description

Bit 9 CC1OF: Capture/Compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.

0: No overcapture has been detected.

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bit 8 Reserved, must be kept at reset value.

Bit 7 BIF: Break interrupt flag

This flag is set by hardware as soon as the break input goes active. It can be cleared by software if the break input is not active.

0: No break event occurred.

1: An active level has been detected on the break input.

Bit 6 TIF: Trigger interrupt flag

This flag is set by hardware on trigger event (active edge detected on TRGI input when the slave mode controller is enabled in all modes but gated mode. It is set when the counter starts or stops when gated mode is selected. It is cleared by software.

0: No trigger event occurred.

1: Trigger interrupt pending.

Bit 5 COMIF: COM interrupt flag

This flag is set by hardware on COM event (when Capture/compare Control bits - CCxE, CCxNE, OCxM - have been updated). It is cleared by software.

0: No COM event occurred.

1: COM interrupt pending.

Bit 4 CC4IF: Capture/Compare 4 interrupt flag
refer to CC1IF description

Bit 3 CC3IF: Capture/Compare 3 interrupt flag
refer to CC1IF description

Bit 2 CC2IF: Capture/Compare 2 interrupt flag
refer to CC1IF description

Bit 1 CC1IF: Capture/Compare 1 interrupt flag

If channel CC1 is configured as output:

This flag is set by hardware when the counter matches the compare value, with some exception in center-aligned mode (refer to the CMS bits in the TIMx_CR1 register description). It is cleared by software.

0: No match.

1: The content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register. When the contents of TIMx_CCR1 are greater than the contents of TIMx_ARR, the CC1IF bit goes high on the counter overflow (in upcounting and up/down-counting modes) or underflow (in downcounting mode)

If channel CC1 is configured as input:

This bit is set by hardware on a capture. It is cleared by software or by reading the TIMx_CCR1 register.

0: No input capture occurred

1: The counter value has been captured in TIMx_CCR1 register (An edge has been detected on IC1 which matches the selected polarity)

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

17.4.6 TIM1 and TIM8 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
ReservedBGTGCOMGCC4GCC3GCC2GCC1GUG
wwwwwwww

Bits 15:8 Reserved, must be kept at reset value.

Bit 7 BG: Break generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A break event is generated. MOE bit is cleared and BIF flag is set. Related interrupt or DMA transfer can occur if enabled.

Bit 6 TG: Trigger generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: The TIF flag is set in TIMx_SR register. Related interrupt or DMA transfer can occur if enabled.

Bit 5 COMG: Capture/Compare control update generation

This bit can be set by software, it is automatically cleared by hardware

0: No action

1: When CCPC bit is set, it allows to update CCxE, CCxNE and OCxM bits

Note: This bit acts only on channels having a complementary output.

Bit 4 CC4G: Capture/Compare 4 generation

refer to CC1G description

Bit 3 CC3G: Capture/Compare 3 generation

refer to CC1G description

Bit 2 CC2G: Capture/Compare 2 generation

refer to CC1G description

Bit 1 CC1G: Capture/Compare 1 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled.

If channel CC1 is configured as input:

The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected). The counter is cleared if the center-aligned mode is selected or if DIR=0 (upcounting), else it takes the auto-reload value (TIMx_ARR) if DIR=1 (downcounting).

17.4.7 TIM1 and TIM8 capture/compare mode register 1 (TIMx_CCMR1)

Address offset: 0x18

Reset value: 0x0000

The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function in input and in output mode. For a given bit, OCxx describes its function when the channel is configured in output, ICxx describes its function when the channel is configured in input. So the user must take care that the same bit can have a different meaning for the input stage and for the output stage.

1514131211109876543210
OC2
CE
OC2M[2:0]OC2
PE
OC2
FE
CC2S[1:0]OC1
CE
OC1M[2:0]OC1
PE
OC1
FE
CC1S[1:0]
IC2F[3:0]IC2PSC[1:0]IC1F[3:0]IC1PSC[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode:

Bit 15 OC2CE: Output compare 2 clear enable

Bits 14:12 OC2M[2:0]: Output compare 2 mode

Bit 11 OC2PE: Output compare 2 preload enable

Bit 10 OC2FE: Output compare 2 fast enable

Bits 9:8 CC2S[1:0]: Capture/Compare 2 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode is working only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = '0' in TIMx_CCER).

Bit 7 OC1CE: Output compare 1 clear enable

OC1CE: Output compare 1 Clear Enable

0: OC1Ref is not affected by the ETRF Input

1: OC1Ref is cleared as soon as a High level is detected on ETRF input

Bits 6:4 OC1M: Output compare 1 mode

These bits define the behavior of the output reference signal OC1REF from which OC1 and OC1N are derived. OC1REF is active high whereas OC1 and OC1N active level depends on CC1P and CC1NP bits.

000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.(this mode is used to generate a timing base).

001: Set channel 1 to active level on match. OC1REF signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

010: Set channel 1 to inactive level on match. OC1REF signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

011: Toggle - OC1REF toggles when TIMx_CNT=TIMx_CCR1.

100: Force inactive level - OC1REF is forced low.

101: Force active level - OC1REF is forced high.

110: PWM mode 1 - In upcounting, channel 1 is active as long as TIMx_CNT<TIMx_CCR1 else inactive. In downcounting, channel 1 is inactive (OC1REF='0') as long as TIMx_CNT>TIMx_CCR1 else active (OC1REF='1').

111: PWM mode 2 - In upcounting, channel 1 is inactive as long as TIMx_CNT<TIMx_CCR1 else active. In downcounting, channel 1 is active as long as TIMx_CNT>TIMx_CCR1 else inactive.

Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

2: In PWM mode 1 or 2, the OCREf level changes only when the result of the comparison changes or when the output compare mode switches from "frozen" mode to "PWM" mode.

3: On channels having a complementary output, this bit field is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the OC1M active bits take the new value from the preloaded bits only when a COM event is generated.

Bit 3 OC1PE: Output compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.

Note: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

Bit 2 OC1FE: Output compare 1 fast enable

This bit is used to accelerate the effect of an event on the trigger in input on the CC output.
0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.

1: An active edge on the trigger input acts like a compare match on CC1 output. Then, OC is set to the compare level independently from the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OCFE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S: Capture/Compare 1 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: CC1 channel is configured as input, IC1 is mapped on TI2

11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC1S bits are writable only when the channel is OFF (CC1E = '0' in TIMx_CCER).

Input capture mode

Bits 15:12 IC2F: Input capture 2 filter

Bits 11:10 IC2PSC[1:0]: Input capture 2 prescaler

Bits 9:8 CC2S: Capture/Compare 2 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = '0' in TIMx_CCER).

Bits 7:4 IC1F[3:0]: Input capture 1 filter

This bit-field defines the frequency used to sample TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

Bits 3:2 IC1PSC: Input capture 1 prescaler

This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).

The prescaler is reset as soon as CC1E='0' (TIMx_CCER register).

Bits 1:0 CC1S: Capture/Compare 1 Selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

Note: CC1S bits are writable only when the channel is OFF (CC1E = '0' in TIMx_CCER).

17.4.8 TIM1 and TIM8 capture/compare mode register 2 (TIMx_CCMR2)

Address offset: 0x1C

Reset value: 0x0000

Refer to the above CCMR1 register description.

1514131211109876543210
OC4
CE
OC4M[2:0]OC4
PE
OC4
FE
CC4S[1:0]OC3
CE.
OC3M[2:0]OC3
PE
OC3
FE
CC3S[1:0]
IC4F[3:0]IC4PSC[1:0]IC3F[3:0]IC3PSC[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode

Input capture mode

Bits 1:0 CC3S: Capture/compare 3 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC3 channel is configured as output

01: CC3 channel is configured as input, IC3 is mapped on TI3

10: CC3 channel is configured as input, IC3 is mapped on TI4

11: CC3 channel is configured as input, IC3 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC3S bits are writable only when the channel is OFF (CC3E = '0' in TIMx_CCER).

17.4.9 TIM1 and TIM8 capture/compare enable register (TIMx_CCER)

Address offset: 0x20

Reset value: 0x0000

1514131211109876543210
CC4NPRes.CC4PCC4ECC3NPCC3NECC3PCC3ECC2NPCC2NECC2PCC2ECC1NPCC1NECC1PCC1E
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 15 CC4NP: Capture/Compare 4 complementary output polarity
refer to CC1NP description

Bit 14 Reserved, must be kept at reset value.

Bit 13 CC4P: Capture/Compare 4 output polarity
refer to CC1P description

Bit 12 CC4E: Capture/Compare 4 output enable
refer to CC1E description

Bit 11 CC3NP: Capture/Compare 3 complementary output polarity
refer to CC1NP description

Bit 10 CC3NE: Capture/Compare 3 complementary output enable
refer to CC1NE description

Bit 9 CC3P: Capture/Compare 3 output polarity
refer to CC1P description

Bit 8 CC3E: Capture/Compare 3 output enable
refer to CC1E description

Bit 7 CC2NP: Capture/Compare 2 complementary output polarity
refer to CC1NP description

Bit 6 CC2NE: Capture/Compare 2 complementary output enable
refer to CC1NE description

Bit 5 CC2P: Capture/Compare 2 output polarity
refer to CC1P description

Bit 4 CC2E: Capture/Compare 2 output enable
refer to CC1E description

Bit 3 CC1NP: Capture/Compare 1 complementary output polarity

CC1 channel configured as output:

0: OC1N active high.

1: OC1N active low.

CC1 channel configured as input:

This bit is used in conjunction with CC1P to define the polarity of TI1FP1 and TI2FP1. Refer to CC1P description.

Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1NP active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Note: This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S="00" (the channel is configured in output).

Bit 2 CC1NE: Capture/Compare 1 complementary output enable

0: Off - OC1N is not active. OC1N level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.

1: On - OC1N signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.

Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1NE active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Bit 1 CC1P: Capture/Compare 1 output polarity

CC1 channel configured as output:

0: OC1 active high

1: OC1 active low

CC1 channel configured as input:

CC1NP/CC1P bits select the active polarity of TI1FP1 and TI2FP1 for trigger or capture operations.

00: non-inverted/rising edge

The circuit is sensitive to TIxFP1 rising edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode or encoder mode).

01: inverted/falling edge

The circuit is sensitive to TIxFP1 falling edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is inverted (trigger operation in gated mode or encoder mode).

10: reserved, do not use this configuration.

11: non-inverted/both edges

The circuit is sensitive to both TIxFP1 rising and falling edges (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode). This configuration must not be used in encoder mode.

Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1P active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Note: This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 0 CC1E: Capture/Compare 1 output enable

CC1 channel configured as output:

0: Off - OC1 is not active. OC1 level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.

1: On - OC1 signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.

CC1 channel configured as input:

This bit determines if a capture of the counter value can actually be done into the input capture/compare register 1 (TIMx_CCR1) or not.

0: Capture disabled.

1: Capture enabled.

Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1E active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Table 95. Output control bits for complementary OCx and OCxN channels with break feature

Control bitsOutput states(1)
MOE bitOSSI bitOSSR bitCCxE bitCCxNE bitOCx output stateOCxN output state
1X000Output Disabled (not driven by the timer), OCx=0, OCx_EN=0Output Disabled (not driven by the timer), OCxN=0, OCxN_EN=0
001Output Disabled (not driven by the timer), OCx=0, OCx_EN=0OCxREF + Polarity OCxN=OCxREF xor CCxNP, OCxN_EN=1
010OCxREF + Polarity
OCx=OCxREF xor CCxP,
OCx_EN=1
Output Disabled (not driven by the timer)
OCxN=0, OCxN_EN=0
011OCREF + Polarity + dead-time
OCx_EN=1
Complementary to OCREF (not OCREF) + Polarity + dead-time
OCxN_EN=1
100Output Disabled (not driven by the timer)
OCx=CCxP, OCx_EN=0
Output Disabled (not driven by the timer)
OCxN=CCxNP, OCxN_EN=0
101Off-State (output enabled with inactive state)
OCx=CCxP, OCx_EN=1
OCxREF + Polarity
OCxN=OCxREF xor CCxNP,
OCxN_EN=1
110OCxREF + Polarity
OCx=OCxREF xor CCxP,
OCx_EN=1
Off-State (output enabled with inactive state)
OCxN=CCxNP, OCxN_EN=1
111OCREF + Polarity + dead-time
OCx_EN=1
Complementary to OCREF (not OCREF) + Polarity + dead-time
OCxN_EN=1
Table 95. Output control bits for complementary OCx and OCxN channels with break feature (continued)
Control bitsOutput states(1)
MOE bitOSSI bitOSSR bitCCxE bitCCxNE bitOCx output stateOCxN output state
00XXXOutput disabled (not driven by the timer anymore). The output state is defined by the GPIO controller and can be High, Low or Hi-Z.
100
01Off-State (output enabled with inactive state)
Asynchronously: OCx=CCxP, OCx_EN=1, OCxN=CCxNP, OCxN_EN=1
Then if the clock is present: OCx=OISx and OCxN=OISxN after a dead-time, assuming that OISx and OISxN do not correspond to OCX and OCxN both in active state
10
11

Note: The state of the external I/O pins connected to the complementary OCx and OCxN channels depends on the OCx and OCxN channel state and the GPIO registers.

17.4.10 TIM1 and TIM8 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000

1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CNT[15:0]: Counter value

17.4.11 TIM1 and TIM8 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency (CK_CNT) is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

17.4.12 TIM1 and TIM8 auto-reload register (TIMx_ARR)

Address offset: 0x2C

ST logo
ST logo

Reset value: 0xFFFF

1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
Bits 15:0 ARR[15:0] : Auto-reload value

ARR is the value to be loaded in the actual auto-reload register.

Refer to Section 17.3.1: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

17.4.13 TIM1 and TIM8 repetition counter register (TIMx_RCR)

Address offset: 0x30

Reset value: 0x0000

1514131211109876543210
ReservedREP[7:0]
rwrwrwrwrwrwrwrw

Bits 15:8 Reserved, must be kept at reset value.

Bits 7:0 REP[7:0] : Repetition counter value

These bits allow the user to set-up the update rate of the compare registers (i.e. periodic transfers from preload to active registers) when preload registers are enable, as well as the update interrupt generation rate, if this interrupt is enable.

Each time the REP_CNT related downcounter reaches zero, an update event is generated and it restarts counting from REP value. As REP_CNT is reloaded with REP value only at the repetition update event U_RC, any write to the TIMx_RCR register is not taken in account until the next repetition update event.

It means in PWM mode (REP+1) corresponds to:

17.4.14 TIM1 and TIM8 capture/compare register 1 (TIMx_CCR1)

Address offset: 0x34

Reset value: 0x0000

1514131211109876543210
CCR1[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR1[15:0]: Capture/Compare 1 value

If channel CC1 is configured as output:

CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC1 output.

If channel CC1 is configured as input:

CCR1 is the counter value transferred by the last input capture 1 event (IC1). The TIMx_CCR1 register is read-only and cannot be programmed.

17.4.15 TIM1 and TIM8 capture/compare register 2 (TIMx_CCR2)

Address offset: 0x38

Reset value: 0x0000

1514131211109876543210
CCR2[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR2[15:0]: Capture/Compare 2 value

If channel CC2 is configured as output:

CCR2 is the value to be loaded in the actual capture/compare 2 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR2 register (bit OC2PE). Else the preload value is copied in the active capture/compare 2 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC2 output.

If channel CC2 is configured as input:

CCR2 is the counter value transferred by the last input capture 2 event (IC2). The TIMx_CCR2 register is read-only and cannot be programmed.

17.4.16 TIM1 and TIM8 capture/compare register 3 (TIMx_CCR3)

Address offset: 0x3C

Reset value: 0x0000

1514131211109876543210
CCR3[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR3[15:0]: Capture/Compare value

If channel CC3 is configured as output:

CCR3 is the value to be loaded in the actual capture/compare 3 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR3 register (bit OC3PE). Else the preload value is copied in the active capture/compare 3 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC3 output.

If channel CC3 is configured as input:

CCR3 is the counter value transferred by the last input capture 3 event (IC3). The TIMx_CCR3 register is read-only and cannot be programmed.

17.4.17 TIM1 and TIM8 capture/compare register 4 (TIMx_CCR4)

Address offset: 0x40

Reset value: 0x0000

1514131211109876543210
CCR4[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR4[15:0]: Capture/Compare value

If channel CC4 is configured as output:

CCR4 is the value to be loaded in the actual capture/compare 4 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR4 register (bit OC4PE). Else the preload value is copied in the active capture/compare 4 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC4 output.

If channel CC4 is configured as input:

CCR4 is the counter value transferred by the last input capture 4 event (IC4). The TIMx_CCR4 register is read-only and cannot be programmed.

17.4.18 TIM1 and TIM8 break and dead-time register (TIMx_BDTR)

Address offset: 0x44

Reset value: 0x0000

1514131211109876543210
MOEAOEBKPBKEOSSROSSILOCK[1:0]DTG[7:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Note: As the bits AOE, BKP, BKE, OSSI, OSSR and DTG[7:0] can be write-locked depending on the LOCK configuration, it can be necessary to configure all of them during the first write access to the TIMx_BDTR register.

Bit 15 MOE: Main output enable

This bit is cleared asynchronously by hardware as soon as the break input is active. It is set by software or automatically depending on the AOE bit. It is acting only on the channels which are configured in output.

0: OC and OCN outputs are disabled or forced to idle state.

1: OC and OCN outputs are enabled if their respective enable bits are set (CCxE, CCxNE in TIMx_CCER register).

See OC/OCN enable description for more details (Section 17.4.9: TIM1 and TIM8 capture/compare enable register (TIMx_CCER)).

Bit 14 AOE: Automatic output enable

0: MOE can be set only by software

1: MOE can be set by software or automatically at the next update event (if the break input is not be active)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 13 BKP: Break polarity

0: Break input BRK is active low

1: Break input BRK is active high

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 12 BKE: Break enable

0: Break inputs (BRK and CSS clock failure event) disabled

1: Break inputs (BRK and CSS clock failure event) enabled

Note: This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 11 OSSR: Off-state selection for Run mode

This bit is used when MOE=1 on channels having a complementary output which are configured as outputs. OSSR is not implemented if no complementary output is implemented in the timer.

See OC/OCN enable description for more details (Section 17.4.9: TIM1 and TIM8 capture/compare enable register (TIMx_CCER)).

0: When inactive, OC/OCN outputs are disabled (OC/OCN enable output signal=0).

1: When inactive, OC/OCN outputs are enabled with their inactive level as soon as CCxE=1 or CCxNE=1. Then, OC/OCN enable output signal=1

Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 10 OSSI: Off-state selection for Idle mode

This bit is used when MOE=0 on channels configured as outputs.

See OC/OCN enable description for more details (Section 17.4.9: TIM1 and TIM8 capture/compare enable register (TIMx_CCER)).

0: When inactive, OC/OCN outputs are disabled (OC/OCN enable output signal=0).

1: When inactive, OC/OCN outputs are forced first with their idle level as soon as CCxE=1 or CCxNE=1. OC/OCN enable output signal=1

Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 9:8 LOCK[1:0]: Lock configuration

These bits offer a write protection against software errors.

00: LOCK OFF - No bit is write protected.

01: LOCK Level 1 = DTG bits in TIMx_BDTR register, OISx and OISxN bits in TIMx_CR2 register and BKE/BKP/AOE bits in TIMx_BDTR register can no longer be written.

10: LOCK Level 2 = LOCK Level 1 + CC Polarity bits (CCxP/CCxNP bits in TIMx_CCER register, as long as the related channel is configured in output through the CCxS bits) as well as OSSR and OSSI bits can no longer be written.

11: LOCK Level 3 = LOCK Level 2 + CC Control bits (OCxM and OCxPE bits in TIMx_CCMRx registers, as long as the related channel is configured in output through the CCxS bits) can no longer be written.

Note: The LOCK bits can be written only once after the reset. Once the TIMx_BDTR register has been written, their content is frozen until the next reset.

Bits 7:0 DTG[7:0]: Dead-time generator setup

This bit-field defines the duration of the dead-time inserted between the complementary outputs. DT correspond to this duration.

\(DTG[7:5]=0xx \Rightarrow DT=DTG[7:0] \times t_{dtg}\) with \(t_{dtg}=t_{DTS}\).

\(DTG[7:5]=10x \Rightarrow DT=(64+DTG[5:0]) \times t_{dtg}\) with \(T_{dtg}=2 \times t_{DTS}\).

\(DTG[7:5]=110 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=8 \times t_{DTS}\).

\(DTG[7:5]=111 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=16 \times t_{DTS}\).

Example if \(T_{DTS}=125ns\) (8MHz), dead-time possible values are:

0 to 15875 ns by 125 ns steps,

16 us to 31750 ns by 250 ns steps,

32 us to 63us by 1 us steps,

64 us to 126 us by 2 us steps

Note: This bit-field can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

17.4.19 TIM1 and TIM8 DMA control register (TIMx_DCR)

Address offset: 0x48

Reset value: 0x0000

1514131211109876543210
ReservedDBL[4:0]ReservedDBA[4:0]
rwrwrwrwrwrwrwrwrwrw

Bits 15:13 Reserved, must be kept at reset value.

Bits 12:8 DBL[4:0]: DMA burst length

This 5-bit vector defines the number of DMA transfers (the timer detects a burst transfer when a read or a write access to the TIMx_DMAR register address is performed).

00000: 1 transfer

00001: 2 transfers

00010: 3 transfers

...

10001: 18 transfers

Bits 7:5 Reserved, must be kept at reset value.

Bits 4:0 DBA[4:0]: DMA base address

This 5-bits vector defines the base-address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.

Example:

00000: TIMx_CR1,
00001: TIMx_CR2,
00010: TIMx_SMCR,
...

Example: Let us consider the following transfer: DBL = 7 transfers and DBA = TIMx_CR1. In this case the transfer is done to/from 7 registers starting from the TIMx_CR1 address.

17.4.20 TIM1 and TIM8 DMA address for full transfer (TIMx_DMAR)

Address offset: 0x4C

Reset value: 0x0000 0000

31302928272625242322212019181716
DMAB[31:16]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
1514131211109876543210
DMAB[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:0 DMAB[31:0]: DMA register for burst accesses

A read or write operation to the DMAR register accesses the register located at the address
(TIMx_CR1 address) + (DBA + DMA index) x 4

where TIMx_CR1 address is the address of the control register 1, DBA is the DMA base address configured in TIMx_DCR register, DMA index is automatically controlled by the DMA transfer, and ranges from 0 to DBL (DBL configured in TIMx_DCR).

Example of how to use the DMA burst feature

In this example the timer DMA burst feature is used to update the contents of the CCRx registers (x = 2, 3, 4) with the DMA transferring half words into the CCRx registers.

This is done in the following steps:

  1. 1. Configure the corresponding DMA channel as follows:
    • – DMA channel peripheral address is the DMAR register address
    • – DMA channel memory address is the address of the buffer in the RAM containing the data to be transferred by DMA into CCRx registers.
    • – Number of data to transfer = 3 (See note below).
    • – Circular mode disabled.
  2. 2. Configure the DCR register by configuring the DBA and DBL bit fields as follows:
    DBL = 3 transfers, DBA = 0xE.
  3. 3. Enable the TIMx update DMA request (set the UDE bit in the DIER register).
  4. 4. Enable TIMx
  5. 5. Enable the DMA channel

Note: This example is for the case where every CCRx register to be updated once. If every CCRx register is to be updated twice for example, the number of data to transfer should be 6. Let's take the example of a buffer in the RAM containing data1, data2, data3, data4, data5 and data6. The data is transferred to the CCRx registers as follows: on the first update DMA request, data1 is transferred to CCR2, data2 is transferred to CCR3, data3 is transferred to CCR4 and on the second update DMA request, data4 is transferred to CCR2, data5 is transferred to CCR3 and data6 is transferred to CCR4.

17.4.21 TIM1 and TIM8 register map

TIM1 and TIM8 registers are mapped as 16-bit addressable registers as described in the table below:

Table 96. TIM1 and TIM8 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1ReservedCKD [1:0]ARPECMS [1:0]DIROPMURSUDISCEN
Reset value000000000000000000000
0x04TIMx_CR2ReservedOIS4OIS3NOIS3OIS2NOIS2OIS1NOIS1TISMMS[2:0]CCDSCCUSReservedCCPC
Reset value000000000000000000000
0x08TIMx_SMCRReservedETPECEETPS [1:0]ETF[3:0]MSMTS[2:0]ReservedSMS[2:0]
Reset value000000000000000000000
0x0CTIMx_DIERReservedTDECOMDECC4DECC3DECC2DECC1DEUDEBIETIECOMIECC4IECC3IECC2IECC1IEUIE
Reset value000000000000000000000
0x10TIMx_SRReservedCC4OFCC3OFCC2OFCC1OFReservedBIFTIFCOMIFCC4IFCC3IFCC2IFCC1IFUIF
Reset value000000000000000000000
0x14TIMx_EGRReservedBGTGCOMGCC4GCC3GCC2GCC1GUG
Reset value000000000000000000000
0x18TIMx_CCMR1
Output compare mode
ReservedOC2CEOC2M [2:0]OC2PEOC2FECC2S [1:0]OC1CEOC1M [2:0]OC1PEOC1FECC1S [1:0]
Reset value0000000000000000000000
TIMx_CCMR1
Input capture mode
ReservedIC2F[3:0]IC2PSC [1:0]CC2S [1:0]IC1F[3:0]IC1PSC [1:0]CC1S [1:0]
Reset value0000000000000000000000
0x1CTIMx_CCMR2
Output compare mode
ReservedOC4CEOC4M [2:0]OC4PEOC4FECC4S [1:0]OC3CEOC3M [2:0]OC3PEOC3FECC3S [1:0]
Reset value0000000000000000000000
TIMx_CCMR2
Input capture mode
ReservedIC4F[3:0]IC4PSC [1:0]CC4S [1:0]IC3F[3:0]IC3PSC [1:0]CC3S [1:0]
Reset value0000000000000000000000

Table 96. TIM1 and TIM8 register map and reset values (continued)

OffsetRegister313029282726252423222120191817161514131211109876543210
0x20TIMx_CCERReservedCC4NPReservedCC4PCC4ECC3NPCC3NECC3PCC3ECC2NPCC2NECC2PCC2ECC1NPCC1NECC1PCC1E
Reset value000000000000000
0x24TIMx_CNTReservedCNT[15:0]
Reset value0000000000000000
0x28TIMx_PSCReservedPSC[15:0]
Reset value0000000000000000
0x2CTIMx_ARRReservedARR[15:0]
Reset value1111111111111111
0x30TIMx_RCRReservedREP[7:0]
Reset value0000000000000000
0x34TIMx_CCR1ReservedCCR1[15:0]
Reset value0000000000000000
0x38TIMx_CCR2ReservedCCR2[15:0]
Reset value0000000000000000
0x3CTIMx_CCR3ReservedCCR3[15:0]
Reset value0000000000000000
0x40TIMx_CCR4ReservedCCR4[15:0]
Reset value0000000000000000
0x44TIMx_BDTRReservedMOEAOEBKPBKEOSSROSSILOCK [1:0]DT[7:0]
Reset value0000000000000000
0x48TIMx_DCRReservedDBL[4:0]ReservedDBA[4:0]
Reset value000000000000
0x4CTIMx_DMARDMAB[31:0]
Reset value00000000000000000000000000000000
Refer to Section 2.3: Memory map for the register boundary addresses.