19. General-purpose timers (TIM9 to TIM14)

This section applies to the whole STM32F4xx family, unless otherwise specified.

19.1 TIM9 to TIM14 introduction

The TIM9 to TIM14 general-purpose timers consist of a 16-bit auto-reload counter driven by a programmable prescaler.

They may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM).

Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler and the RCC clock controller prescalers.

The TIM9 to TIM14 timers are completely independent, and do not share any resources. They can be synchronized together as described in Section 19.3.12.

19.2 TIM9 to TIM14 main features

19.2.1 TIM9/TIM12 main features

The features of the TIM9 to TIM14 general-purpose timers include:

Figure 180. General-purpose timer block diagram (TIM9 and TIM12)

Block diagram of a general-purpose timer (TIM9 and TIM12) showing internal components and signal flow.

The diagram illustrates the internal architecture of a general-purpose timer (TIM9 and TIM12). It shows the following components and signal paths:

Block diagram of a general-purpose timer (TIM9 and TIM12) showing internal components and signal flow.

19.2.2 TIM10/TIM11 and TIM13/TIM14 main features

The features of general-purpose timers TIM10/TIM11 and TIM13/TIM14 include:

Figure 181. General-purpose timer block diagram (TIM10/11/13/14)

Block diagram of a general-purpose timer (TIM10/11/13/14) showing internal components and signal flow.

The diagram illustrates the internal architecture of a general-purpose timer (TIM10/11/13/14). It shows the flow of signals from external inputs through various internal blocks to the output.

External Signals:

Internal Blocks and Signal Flow:

Notes:

ai17725c

Block diagram of a general-purpose timer (TIM10/11/13/14) showing internal components and signal flow.

19.3 TIM9 to TIM14 functional description

19.3.1 Time-base unit

The main block of the timer is a 16-bit counter with its related auto-reload register. The counter counts up.

The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. Writing to or reading from the auto-reload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the auto-reload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in details for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).

Note that the counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 182 and Figure 183 give some examples of the counter behavior when the prescaler ratio is changed on the fly.

Figure 182. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 2 when the Prescaler control register is updated from 0 to 1.

The diagram illustrates the timing of a prescaler division change from 1 to 2. The CK_PSC signal is a continuous clock. The CEN signal is high during the active period. The Timerclock = CK_CNT is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. The Update event (UEV) is a pulse at the end of each counter rollover. The Prescaler control register is updated from 0 to 1. The Prescaler buffer reflects this change. The Prescaler counter counts from 0 to 1, then back to 0, indicating a division by 2.

MS31076V2

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 2 when the Prescaler control register is updated from 0 to 1.

Figure 183. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 4 when the Prescaler control register is updated from 0 to 3.

The diagram illustrates the timing of a prescaler division change from 1 to 4. The CK_PSC signal is a continuous clock. The CEN signal is high during the active period. The Timerclock = CK_CNT is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. The Update event (UEV) is a pulse at the end of each counter rollover. The Prescaler control register is updated from 0 to 3. The Prescaler buffer reflects this change. The Prescaler counter counts from 0 to 3, then back to 0, indicating a division by 4.

MS31077V2

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 4 when the Prescaler control register is updated from 0 to 3.

19.3.2 Counter modes

Upcounting mode

In upcounting mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller on TIM9 and TIM12) also generates an update event.

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 184. Counter timing diagram, internal clock divided by 1

Timing diagram for counter upcounting mode showing CK_PSC, CNT_EN, Timerclock, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

The diagram illustrates the timing of various signals during an upcounting mode overflow event. The counter register is shown incrementing from 31 to 36, then wrapping around to 00. The counter overflow and update event (UEV) signals are generated at the overflow point. The update interrupt flag (UIF) is set after the update event.

SignalState/Value
CK_PSCContinuous clock signal
CNT_ENHigh (enabled)
Timerclock = CK_CNTClock signal derived from CK_PSC
Counter register31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07
Counter overflowPulse at overflow (36 to 00)
Update event (UEV)Pulse at overflow (36 to 00)
Update interrupt flag (UIF)Set after UEV

MS31078V3

Timing diagram for counter upcounting mode showing CK_PSC, CNT_EN, Timerclock, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 185. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is active high and enables the counter. The Timerclock = CK_CNT signal is a square wave with a 50% duty cycle, derived from CK_PSC. The Counter register shows the sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, 0003. A counter overflow occurs when the register value reaches 0036 and rolls over to 0000. This overflow triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF).

MS31079V3

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 186. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram shows the counter operation with the internal clock divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is active high. The Timerclock = CK_CNT signal has a 25% duty cycle. The Counter register values shown are 0035, 0036, 0000, and 0001. Overflow occurs at 0036, triggering the UEV and setting the UIF.

MS31080V3

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 187. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram depicts the counter operation with an arbitrary division factor N. The CK_PSC signal is a high-frequency square wave. The Timerclock = CK_CNT signal has a variable duty cycle. The Counter register values shown are 1F, 20, and 00. Overflow occurs at 20, triggering the UEV and setting the UIF.

MS31081V3

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 188. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Timing diagram for ARPE=0 showing CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

This timing diagram illustrates the behavior of a timer when ARPE=0 and the TIMx_ARR register is not preloaded. The diagram shows the following signals over time:

The diagram shows that the update event occurs immediately after the counter reaches 36 and wraps to 00. The auto-reload preload register is updated with a new value (FF) before the counter reaches 36.

Timing diagram for ARPE=0 showing CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Figure 189. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Timing diagram for ARPE=1 showing CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register.

This timing diagram illustrates the behavior of a timer when ARPE=1 and the TIMx_ARR register is preloaded. The diagram shows the following signals over time:

The diagram shows that the update event occurs immediately after the counter reaches F5 and wraps to 00. The auto-reload preload register and auto-reload shadow register are updated with a new value (F5) before the counter reaches F5.

Timing diagram for ARPE=1 showing CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register.

19.3.3 Clock selection

The counter clock can be provided by the following clock sources:

Internal clock source (CK_INT)

The internal clock source is the default clock source for TIM10/TIM11 and TIM13/TIM14.

For TIM9 and TIM12, the internal clock source is selected when the slave mode controller is disabled (SMS='000'). The CEN bit in the TIMx_CR1 register and the UG bit in the TIMx_EGR register are then used as control bits and can be changed only by software (except for UG which remains cleared). As soon as the CEN bit is programmed to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 190 shows the behavior of the control circuit and of the upcounter in normal mode, without prescaler.

Figure 190. Control circuit in normal mode, internal clock divided by 1

Timing diagram for Figure 190 showing the behavior of the control circuit and upcounter in normal mode without a prescaler. The diagram includes waveforms for Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and the Counter register. The counter register shows values from 31 to 07, with a rollover from 36 to 00. The counter clock is derived from the internal clock when CEN is high. The UG signal is a pulse that triggers the counter to reset to 00.

The diagram illustrates the timing relationship between the internal clock, control signals, and the counter register. The internal clock is a continuous square wave. The CEN=CNT_EN signal is a high-level pulse that enables the counter. The UG signal is a high-level pulse that triggers the counter to reset to 00. The CNT_INIT signal is a high-level pulse that triggers the counter to reset to 00. The counter clock is derived from the internal clock when CEN is high. The counter register shows values from 31 to 07, with a rollover from 36 to 00.

MS31085V2

Timing diagram for Figure 190 showing the behavior of the control circuit and upcounter in normal mode without a prescaler. The diagram includes waveforms for Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and the Counter register. The counter register shows values from 31 to 07, with a rollover from 36 to 00. The counter clock is derived from the internal clock when CEN is high. The UG signal is a pulse that triggers the counter to reset to 00.

External clock source mode 1(TIM9 and TIM12)

This mode is selected when SMS='111' in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.

Figure 191. TI2 external clock connection example

Figure 191. TI2 external clock connection example block diagram showing TI2 input through Filter (ICF[3:0] in TIMx_CCMR1), Edge detector (CC2P in TIMx_CCER) outputting TI2F_Rising and TI2F_Falling multiplexed into TI2FP2 and TI2FP1, TS[2:0] multiplexer with inputs ITRx, TI1_ED, TI1FP1, TI2FP2 to output TRGI, and external/internal clock multiplexer controlled by SMS[2:0] in TIMx_SMCR outputting CK_PSC.
Figure 191. TI2 external clock connection example block diagram showing TI2 input through Filter (ICF[3:0] in TIMx_CCMR1), Edge detector (CC2P in TIMx_CCER) outputting TI2F_Rising and TI2F_Falling multiplexed into TI2FP2 and TI2FP1, TS[2:0] multiplexer with inputs ITRx, TI1_ED, TI1FP1, TI2FP2 to output TRGI, and external/internal clock multiplexer controlled by SMS[2:0] in TIMx_SMCR outputting CK_PSC.

For example, to configure the upcounter to count in response to a rising edge on the TI2 input, use the following procedure:

  1. 1. Configure channel 2 to detect rising edges on the TI2 input by writing CC2S = ‘01’ in the TIMx_CCMR1 register.
  2. 2. Configure the input filter duration by writing the IC2F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC2F=’0000’).
  3. 3. Select the rising edge polarity by writing CC2P=’0’ and CC2NP=’0’ in the TIMx_CCER register.
  4. 4. Configure the timer in external clock mode 1 by writing SMS=’111’ in the TIMx_SMCR register.
  5. 5. Select TI2 as the trigger input source by writing TS=’110’ in the TIMx_SMCR register.
  6. 6. Enable the counter by writing CEN=’1’ in the TIMx_CR1 register.

Note: The capture prescaler is not used for triggering, so no need to configure it.

When a rising edge occurs on TI2, the counter counts once and the TIF flag is set.

The delay between the rising edge on TI2 and the actual clock of the counter is due to the resynchronization circuit on TI2 input.

Figure 192. Control circuit in external clock mode 1

Figure 192. Control circuit in external clock mode 1 timing diagram showing TI2, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register (incrementing 34, 35, 36), and TIF with indication of Write TIF = 0.
Figure 192. Control circuit in external clock mode 1 timing diagram showing TI2, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register (incrementing 34, 35, 36), and TIF with indication of Write TIF = 0.

19.3.4 Capture/compare channels

Each Capture/Compare channel is built around a capture/compare register (including a shadow register), a input stage for capture (with digital filter, multiplexing and prescaler) and an output stage (with comparator and output control).

Figure 193 to Figure 195 give an overview of a capture/compare channel.

The input stage samples the corresponding TIx input to generate a filtered signal TIxF. Then, an edge detector with polarity selection generates a signal (TIxFPx) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).

Figure 193. Capture/compare channel (example: channel 1 input stage)

Block diagram of the capture/compare channel (example: channel 1 input stage). It illustrates the path of input signal TI1 through a filter downcounter (controlled by f_DTS and ICF[3:0] in TIMx_CCMR1) producing TI1F, then through an edge detector producing TI1F_Rising and TI1F_Falling. These signals go into a 2-to-1 selector producing TI1FP1 (controlled by CC1P/CC1NP in TIMx_CCER). TI1FP1 and TI1F_ED output to the slave mode controller. A multiplexer with inputs 01 (TI1FP1), 10 (TI2FP1 from TI2F_Rising/Falling via channel 2 selector), and 11 (TRC from slave mode controller) outputs IC1, which passes through a divider (/1, /2, /4, /8) controlled by CC1S[1:0] and ICPS[1:0] (TIMx_CCMR1) and CC1E (TIMx_CCER) to yield IC1PS.

MS33115V1

Block diagram of the capture/compare channel (example: channel 1 input stage). It illustrates the path of input signal TI1 through a filter downcounter (controlled by f_DTS and ICF[3:0] in TIMx_CCMR1) producing TI1F, then through an edge detector producing TI1F_Rising and TI1F_Falling. These signals go into a 2-to-1 selector producing TI1FP1 (controlled by CC1P/CC1NP in TIMx_CCER). TI1FP1 and TI1F_ED output to the slave mode controller. A multiplexer with inputs 01 (TI1FP1), 10 (TI2FP1 from TI2F_Rising/Falling via channel 2 selector), and 11 (TRC from slave mode controller) outputs IC1, which passes through a divider (/1, /2, /4, /8) controlled by CC1S[1:0] and ICPS[1:0] (TIMx_CCMR1) and CC1E (TIMx_CCER) to yield IC1PS.

The output stage generates an intermediate waveform which is then used for reference: OCxRef (active high). The polarity acts at the end of the chain.

Figure 194. Capture/compare channel 1 main circuit

Figure 194: Capture/compare channel 1 main circuit diagram. The diagram shows the internal logic of the channel, including the APB Bus, MCU-peripheral interface, Capture/compare preload register, Capture/compare shadow register, Counter, and Comparator. It details the data paths for reading and writing CCR1H and CCR1L, the capture and compare transfer mechanisms, and the generation of output mode signals (OC1PE, UEV) based on the counter's relationship to the preload register.

The diagram illustrates the main circuit of Capture/compare channel 1. At the top, the APB Bus connects to the MCU-peripheral interface, which in turn connects to the Capture/compare preload register. This register is 16-bit wide, with 8-bit high and low parts. The preload register is connected to a shadow register. The shadow register is connected to a Counter. The Counter is connected to a Comparator. The Comparator outputs two signals: CNT > CCR1 and CNT = CCR1. The Comparator also outputs a signal to the Output mode block. The Output mode block is connected to the OC1PE and UEV signals. The OC1PE signal is connected to the TIMx_CCMR1 register. The UEV signal is connected to the TIMx_CCMR1 register. The TIMx_EGR register is connected to the Counter. The TIMx_CCMR1 register is connected to the Counter. The TIMx_CCMR1 register is connected to the Output mode block. The TIMx_CCMR1 register is connected to the Output enable circuit. The TIMx_CCMR1 register is connected to the Output mode controller. The TIMx_CCMR1 register is connected to the Output mode controller. The TIMx_CCMR1 register is connected to the Output mode controller.

Figure 194: Capture/compare channel 1 main circuit diagram. The diagram shows the internal logic of the channel, including the APB Bus, MCU-peripheral interface, Capture/compare preload register, Capture/compare shadow register, Counter, and Comparator. It details the data paths for reading and writing CCR1H and CCR1L, the capture and compare transfer mechanisms, and the generation of output mode signals (OC1PE, UEV) based on the counter's relationship to the preload register.

Figure 195. Output stage of capture/compare channel (channel 1)

Figure 195: Output stage of capture/compare channel (channel 1) diagram. The diagram shows the output stage of the channel, including the Output mode controller, OC1_REF signal, a multiplexer, and the Output enable circuit. It details the control signals for the output stage, including CNT > CCR2, CNT = CCR2, OC2M[2:0], CC1P, and CC1E.

The diagram illustrates the output stage of capture/compare channel 1. The Output mode controller receives inputs from CNT > CCR2 and CNT = CCR2. It outputs the OC1_REF signal. The OC1_REF signal is connected to a multiplexer. The multiplexer has two inputs: 0 and 1. The input 0 is connected to the OC1_REF signal. The input 1 is connected to the CC1P signal. The multiplexer output is connected to the Output enable circuit. The Output enable circuit receives inputs from CC1E and TIMx_CCMR1. The Output enable circuit outputs the OC1 signal. The OC1 signal is connected to the master mode controller. The OC1 signal is connected to the master mode controller. The OC1 signal is connected to the master mode controller.

Figure 195: Output stage of capture/compare channel (channel 1) diagram. The diagram shows the output stage of the channel, including the Output mode controller, OC1_REF signal, a multiplexer, and the Output enable circuit. It details the control signals for the output stage, including CNT > CCR2, CNT = CCR2, OC2M[2:0], CC1P, and CC1E.

The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.

In capture mode, captures are actually done in the shadow register, which is copied into the preload register.

In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.

19.3.5 Input capture mode

In Input capture mode, the Capture/Compare registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCxIF flag was already high, then the over-capture flag CCxOF (TIMx_SR register) is set. CCxIF can be

cleared by software by writing it to '0' or by reading the captured data stored in the TIMx_CCRx register. CCxOF is cleared when the user writes it to '0'.

The following example shows how to capture the counter value in TIMx_CCR1 when TI1 input rises. To do this, use the following procedure:

  1. 1. Select the active input: TIMx_CCR1 must be linked to the TI1 input, so write the CC1S bits to '01' in the TIMx_CCMR1 register. As soon as CC1S becomes different from '00', the channel is configured in input mode and the TIMx_CCR1 register becomes read-only.
  2. 2. Program the needed input filter duration with respect to the signal connected to the timer (by programming the ICxF bits in the TIMx_CCMRx register if the input is one of the TIx inputs). Let us imagine that, when toggling, the input signal is not stable during at least five internal clock cycles. We must program a filter duration longer than these 5 clock cycles. We can validate a transition on TI1 when eight consecutive samples with the new level have been detected (sampled at \(f_{DTS}\) frequency). Then write IC1F bits to '0011' in the TIMx_CCMR1 register.
  3. 3. Select the edge of the active transition on the TI1 channel by programming CC1P and CC1NP bits to '00' in the TIMx_CCER register (rising edge in this case).
  4. 4. Program the input prescaler. In our example, we wish the capture to be performed at each valid transition, so the prescaler is disabled (write IC1PS bits to '00' in the TIMx_CCMR1 register).
  5. 5. Enable capture from the counter into the capture register by setting the CC1E bit in the TIMx_CCER register.
  6. 6. If needed, enable the related interrupt request by setting the CC1IE bit in the TIMx_DIER register.

When an input capture occurs:

In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which could happen after reading the flag and before reading the data.

Note: IC interrupt requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.

19.3.6 PWM input mode (only for TIM9/12)

This mode is a particular case of input capture mode. The procedure is the same except:

For example, the user can measure the period (in TIMx_CCR1 register) and the duty cycle (in TIMx_CCR2 register) of the PWM applied on TI1 using the following procedure (depending on CK_INT frequency and prescaler value):

  1. 1. Select the active input for TIMx_CCR1: write the CC1S bits to '01' in the TIMx_CCMR1 register (TI1 selected).
  2. 2. Select the active polarity for TI1FP1 (used both for capture in TIMx_CCR1 and counter clear): program the CC1P and CC1NP bits to '00' (active on rising edge).
  3. 3. Select the active input for TIMx_CCR2: write the CC2S bits to '10' in the TIMx_CCMR1 register (TI1 selected).
  4. 4. Select the active polarity for TI1FP2 (used for capture in TIMx_CCR2): write the CC2P bit to '1' and the CC2NP bit to '0' (active on falling edge).
  5. 5. Select the valid trigger input: write the TS bits to '101' in the TIMx_SMCR register (TI1FP1 selected).
  6. 6. Configure the slave mode controller in reset mode: write the SMS bits to '100' in the TIMx_SMCR register.
  7. 7. Enable the captures: write the CC1E and CC2E bits to '1' in the TIMx_CCER register.

Figure 196. PWM input mode timing

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, TIMx_CCR1 duty cycle capture, and TIMx_CCR2 period capture. It illustrates three events: IC1 capture/IC2 capture/reset counter, IC2 capture/duty width measurement, and IC1 capture/period measurement.

The diagram shows the following signals and events:

Three capture events are marked with arrows:

  1. IC1 capture, IC2 capture, reset counter: Occurs at the first falling edge of TI1, where the counter is 0004.
  2. IC2 capture, duty width measurement: Occurs at the second falling edge of TI1, where the counter is 0002.
  3. IC1 capture, period measurement: Occurs at the third falling edge of TI1, where the counter is 0000.

ai15413

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, TIMx_CCR1 duty cycle capture, and TIMx_CCR2 period capture. It illustrates three events: IC1 capture/IC2 capture/reset counter, IC2 capture/duty width measurement, and IC1 capture/period measurement.
  1. 1. The PWM input mode can be used only with the TIMx_CH1/TIMx_CH2 signals due to the fact that only TI1FP1 and TI2FP2 are connected to the slave mode controller.

19.3.7 Forced output mode

In output mode (CCxS bits = '00' in the TIMx_CCMRx register), each output compare signal (OCxREF and then OCx) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.

To force an output compare signal (OCXREF/OCx) to its active level, the user just needs to write '101' in the OCxM bits in the corresponding TIMx_CCMRx register. Thus OCXREF is forced high (OCxREF is always active high) and OCx get opposite value to CCxP polarity bit.

For example: CCxP='0' (OCx active high) => OCx is forced to high level.

The OCxREF signal can be forced low by writing the OCxM bits to '100' in the TIMx_CCMRx register.

Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt requests can be sent accordingly. This is described in the output compare mode section below.

19.3.8 Output compare mode

This function is used to control an output waveform or indicating when a period of time has elapsed.

When a match is found between the capture/compare register and the counter, the output compare function:

  1. 1. Assigns the corresponding output pin to a programmable value defined by the output compare mode (OCxM bits in the TIMx_CCMRx register) and the output polarity (CCxP bit in the TIMx_CCER register). The output pin can keep its level (OCxM='000'), be set active (OCxM='001'), be set inactive (OCxM='010') or can toggle (OCxM='011') on match.
  2. 2. Sets a flag in the interrupt status register (CCxIF bit in the TIMx_SR register).
  3. 3. Generates an interrupt if the corresponding interrupt mask is set (CCxIE bit in the TIMx_DIER register).

The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.

In output compare mode, the update event UEV has no effect on OCxREF and OCx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One-pulse mode).

Procedure:

  1. 1. Select the counter clock (internal, external, prescaler).
  2. 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
  3. 3. Set the CCxIE bit if an interrupt request is to be generated.
  4. 4. Select the output mode. For example:
    • – Write OCxM = '011' to toggle OCx output pin when CNT matches CCRx
    • – Write OCxPE = '0' to disable preload register
    • – Write CCxP = '0' to select active high polarity
    • – Write CCxE = '1' to enable the output
  5. 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.

The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE='0', else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 197.

Figure 197. Output compare mode, toggle on OC1.

Timing diagram for output compare mode, toggle on OC1. It shows three signals: TIM1_CNT, TIM1_CCR1, and OC1REF=OC1. TIM1_CNT is a counter increasing from 0039 to 003A, 003B, then skipping to B200 and B201. TIM1_CCR1 holds 003A and then switches to B201. OC1REF=OC1 is a square wave that toggles at each match between TIM1_CNT and TIM1_CCR1. A write to B201h in the CC1R register is shown occurring between 003B and B200. A match is detected on CCR1, and an interrupt is generated if enabled.

Write B201h in the CC1R register

TIM1_CNT: 0039, 003A, 003B, ..., B200, B201

TIM1_CCR1: 003A, ..., B201

OC1REF= OC1: [Square wave toggling at matches]

Match detected on CCR1
Interrupt generated if enabled

MS31092V2

Timing diagram for output compare mode, toggle on OC1. It shows three signals: TIM1_CNT, TIM1_CCR1, and OC1REF=OC1. TIM1_CNT is a counter increasing from 0039 to 003A, 003B, then skipping to B200 and B201. TIM1_CCR1 holds 003A and then switches to B201. OC1REF=OC1 is a square wave that toggles at each match between TIM1_CNT and TIM1_CCR1. A write to B201h in the CC1R register is shown occurring between 003B and B200. A match is detected on CCR1, and an interrupt is generated if enabled.

19.3.9 PWM mode

Pulse Width Modulation mode allows the user to generate a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.

The PWM mode can be selected independently on each channel (one PWM per OCx output) by writing '110' (PWM mode 1) or '111' (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. Enable the corresponding preload register by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the auto-reload preload register by setting the ARPE bit in the TIMx_CR1 register.

As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, the user has to initialize all the registers by setting the UG bit in the TIMx_EGR register.

The OCx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. The OCx output is enabled by the CCxE bit in the TIMx_CCER register. Refer to the TIMx_CCERx register description for more details.

In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CNT ≤ TIMx_CCRx.

The timer is able to generate PWM in edge-aligned mode only since the counter is upcounting.

PWM edge-aligned mode

In the following example, we consider PWM mode 1. The reference PWM signal OCxREF is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the compare value in

TIMx_CCRx is greater than the auto-reload value (in TIMx_ARR) then OCxREF is held at '1'. If the compare value is 0 then OCxRef is held at '0'. Figure 198 shows some edge-aligned PWM waveforms in an example where TIMx_ARR=8.

Figure 198. Edge-aligned PWM waveforms (ARR=8)

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register (0-8, 0-1), OCXREF, and CCxIF for CCRx=4, CCRx=8, CCRx>8, and CCRx=0. Vertical dashed lines indicate the start of each period. For CCRx=4, OCXREF is high from counter 0 to 3 and low from 4 to 7. For CCRx=8, OCXREF is high from 0 to 7 and low from 8 to 0. For CCRx>8, OCXREF is high from 0 to 7. For CCRx=0, OCXREF is low from 0 to 7. CCxIF is high when the counter matches CCRx.

MS31093V1

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register (0-8, 0-1), OCXREF, and CCxIF for CCRx=4, CCRx=8, CCRx>8, and CCRx=0. Vertical dashed lines indicate the start of each period. For CCRx=4, OCXREF is high from counter 0 to 3 and low from 4 to 7. For CCRx=8, OCXREF is high from 0 to 7 and low from 8 to 0. For CCRx>8, OCXREF is high from 0 to 7. For CCRx=0, OCXREF is low from 0 to 7. CCxIF is high when the counter matches CCRx.

19.3.10 One-pulse mode

One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.

Starting the counter can be controlled through the slave mode controller. Generating the waveform can be done in output compare mode or PWM mode. Select One-pulse mode by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.

A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting (when the timer is waiting for the trigger), the configuration must be as follows:

\[CNT < CCRx \leq ARR \text{ (in particular, } 0 < CCRx)\]

Figure 199. Example of one pulse mode.

Timing diagram for one pulse mode showing TI2, OC1REF, OC1, Counter, TIM1_ARR, and TIM1_CCR1 signals over time t. A rising edge on TI2 triggers a delay t_DELAY before the counter starts. The counter increments until it reaches TIM1_CCR1, at which point OC1 transitions from low to high. The counter continues to increment until it reaches TIM1_ARR, at which point OC1 transitions from high to low. The duration of the high pulse on OC1 is t_PULSE. OC1REF is a reference signal that is high when OC1 is low and low when OC1 is high.

MS31099V1

Timing diagram for one pulse mode showing TI2, OC1REF, OC1, Counter, TIM1_ARR, and TIM1_CCR1 signals over time t. A rising edge on TI2 triggers a delay t_DELAY before the counter starts. The counter increments until it reaches TIM1_CCR1, at which point OC1 transitions from low to high. The counter continues to increment until it reaches TIM1_ARR, at which point OC1 transitions from high to low. The duration of the high pulse on OC1 is t_PULSE. OC1REF is a reference signal that is high when OC1 is low and low when OC1 is high.

For example the user may want to generate a positive pulse on OC1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\) as soon as a positive edge is detected on the TI2 input pin.

Use TI2FP2 as trigger 1:

  1. 1. Map TI2FP2 to TI2 by writing CC2S='01' in the TIMx_CCMR1 register.
  2. 2. TI2FP2 must detect a rising edge, write CC2P='0' and CC2NP = '0' in the TIMx_CCER register.
  3. 3. Configure TI2FP2 as trigger for the slave mode controller (TRGI) by writing TS='110' in the TIMx_SMCR register.
  4. 4. TI2FP2 is used to start the counter by writing SMS to '110' in the TIMx_SMCR register (trigger mode).

The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).

The user only wants one pulse (Single mode), so write '1' in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over from the auto-reload value back to 0). When OPM bit in the TIMx_CR1 register is set to '0', so the Repetitive mode is selected.

Particular case: OCx fast enable

In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{DELAY\ min}\) we can get.

If the user wants to output a waveform with the minimum delay, set the OCxFE bit in the TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.

19.3.11 TIM9/12 external trigger synchronization

The TIM9/12 timers can be synchronized with an external trigger in several modes: Reset mode, Gated mode and Trigger mode.

Slave mode: Reset mode

The counter and its prescaler can be reinitialized in response to an event on a trigger input. Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated.

In the following example, the upcounter is cleared in response to a rising edge on TI1 input:

  1. 1. Configure the channel 1 to detect rising edges on TI1. Configure the input filter duration (in this example, no need of any filter, IC1F = 0000 kept). The capture prescaler is not used for triggering, so there's no need to configure it. The CC1S bits select the input capture source only, CC1S = '01' in the TIMx_CCMR1 register. Program CC1P and CC1NP to '00' in TIMx_CCER register to validate the polarity (and detect rising edges only).
  2. 2. Configure the timer in reset mode by writing SMS='100' in TIMx_SMCR register. Select TI1 as the input source by writing TS='101' in TIMx_SMCR register.
  3. 3. Start the counter by writing CEN='1' in the TIMx_CR1 register.

The counter starts counting on the internal clock, then behaves normally until TI1 rising edge. When TI1 rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request can be sent if enabled (depending on the TIE bit in TIMx_DIER register).

The following figure shows this behavior when the auto-reload register TIMx_ARR=0x36. The delay between the rising edge on TI1 and the actual reset of the counter is due to the resynchronization circuit on TI1 input.

Figure 200. Control circuit in reset mode

Timing diagram for Figure 200: Control circuit in reset mode. The diagram shows five signals over time: TI1, UG, Counter clock = ck_cnt = ck_psc, Counter register, and TIF. TI1 is a low-level pulse. UG is a high-level pulse that occurs during the TI1 low pulse. The Counter clock is a continuous square wave. The Counter register shows a sequence of values: 30, 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 00, 01, 02, 03. The TIF flag is high during the TI1 low pulse and low otherwise. Vertical dashed lines indicate the start and end of the TI1 low pulse, which correspond to the start and end of the counter register sequence.

MS31401V2

Timing diagram for Figure 200: Control circuit in reset mode. The diagram shows five signals over time: TI1, UG, Counter clock = ck_cnt = ck_psc, Counter register, and TIF. TI1 is a low-level pulse. UG is a high-level pulse that occurs during the TI1 low pulse. The Counter clock is a continuous square wave. The Counter register shows a sequence of values: 30, 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 00, 01, 02, 03. The TIF flag is high during the TI1 low pulse and low otherwise. Vertical dashed lines indicate the start and end of the TI1 low pulse, which correspond to the start and end of the counter register sequence.

Slave mode: Gated mode

The counter can be enabled depending on the level of a selected input.

In the following example, the upcounter counts only when TI1 input is low:

  1. 1. Configure the channel 1 to detect low levels on TI1. Configure the input filter duration (in this example, no need of any filter, IC1F='0000' kept). The capture prescaler is not used for triggering, so there's no need to configure it. The CC1S bits select the input capture source only, CC1S='01' in TIMx_CCMR1 register. Program CC1P='1' and CC1NP= '0' in TIMx_CCER register to validate the polarity (and detect low level only).
  2. 2. Configure the timer in gated mode by writing SMS='101' in TIMx_SMCR register. Select TI1 as the input source by writing TS='101' in TIMx_SMCR register.
  3. 3. Enable the counter by writing CEN='1' in the TIMx_CR1 register (in gated mode, the counter does not start if CEN='0', whatever is the trigger input level).

The counter starts counting on the internal clock as long as TI1 is low and stops as soon as TI1 becomes high. The TIF flag in the TIMx_SR register is set both when the counter starts or stops.

The delay between the rising edge on TI1 and the actual stop of the counter is due to the resynchronization circuit on TI1 input.

Figure 201. Control circuit in gated mode

Timing diagram for Figure 201 showing TI1, cnt_en, Counter clock, Counter register, and TIF signals. The counter clock is gated by cnt_en. The counter register shows bits 30-38, with bit 34 being the overflow flag. TIF is set when the counter overflows and cleared by writing TIF=0.

The diagram illustrates the control circuit in gated mode. It shows the relationship between the input signal TI1, the enable signal cnt_en, the counter clock (ck_cnt = ck_psc), the counter register, and the timer interrupt flag (TIF). The counter clock is gated by cnt_en. The counter register is shown with bits 30 through 38, with bit 34 being the overflow flag. TIF is set when the counter overflows and cleared by writing TIF=0.

Timing diagram for Figure 201 showing TI1, cnt_en, Counter clock, Counter register, and TIF signals. The counter clock is gated by cnt_en. The counter register shows bits 30-38, with bit 34 being the overflow flag. TIF is set when the counter overflows and cleared by writing TIF=0.

Slave mode: Trigger mode

The counter can start in response to an event on a selected input.

In the following example, the upcounter starts in response to a rising edge on TI2 input:

  1. 1. Configure the channel 2 to detect rising edges on TI2. Configure the input filter duration (in this example, no need of any filter, IC2F='0000' kept). The capture prescaler is not used for triggering, so there's no need to configure it. The CC2S bits are configured to select the input capture source only, CC2S='01' in TIMx_CCMR1 register. Program CC2P='1' and CC2NP='0' in TIMx_CCER register to validate the polarity (and detect low level only).
  2. 2. Configure the timer in trigger mode by writing SMS='110' in TIMx_SMCR register. Select TI2 as the input source by writing TS='110' in TIMx_SMCR register.

When a rising edge occurs on TI2, the counter starts counting on the internal clock and the TIF flag is set.

The delay between the rising edge on TI2 and the actual start of the counter is due to the resynchronization circuit on TI2 input.

Figure 202. Control circuit in trigger mode

Timing diagram for Figure 202 showing TI2, cnt_en, Counter clock, Counter register, and TIF signals. The counter starts counting on the rising edge of TI2. The counter register shows bits 30-38, with bit 34 being the overflow flag. TIF is set when the counter overflows.

The diagram illustrates the control circuit in trigger mode. It shows the relationship between the input signal TI2, the enable signal cnt_en, the counter clock (ck_cnt = ck_psc), the counter register, and the timer interrupt flag (TIF). The counter starts counting on the rising edge of TI2. The counter register is shown with bits 30 through 38, with bit 34 being the overflow flag. TIF is set when the counter overflows.

Timing diagram for Figure 202 showing TI2, cnt_en, Counter clock, Counter register, and TIF signals. The counter starts counting on the rising edge of TI2. The counter register shows bits 30-38, with bit 34 being the overflow flag. TIF is set when the counter overflows.

19.3.12 Timer synchronization (TIM9/12)

The TIM timers are linked together internally for timer synchronization or chaining. Refer to Section 18.3.15: Timer synchronization for details.

Note: The clock of the slave timer must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

19.3.13 Debug mode

When the microcontroller enters debug mode (Cortex®-M4 with FPU core halted), the TIMx counter either continues to work normally or stops, depending on DBG_TIMx_STOP configuration bit in DBG module. For more details, refer to Section 38.16.2: Debug support for timers, watchdog, bxCAN and I2C.

19.4 TIM9 and TIM12 registers

Refer to Section 2.2 for a list of abbreviations used in register descriptions.

The peripheral registers have to be written by half-words (16 bits) or words (32 bits). Read accesses can be done by bytes (8 bits), half-words (16 bits) or words (32 bits).

19.4.1 TIM9/12 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
ReservedCKD[1:0]ARPEReservedOPMURSUDISCEN
rwrwrwrwrwrwrw

Bits 15:10 Reserved, must be kept at reset value.

Bits 9:8 CKD: Clock division

This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and sampling clock used by the digital filters (Tlx),

00: \(t_{DTS} = t_{CK\_INT}\)

01: \(t_{DTS} = 2 \times t_{CK\_INT}\)

10: \(t_{DTS} = 4 \times t_{CK\_INT}\)

11: Reserved

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered.

1: TIMx_ARR register is buffered.

Bits 6:4 Reserved, must be kept at reset value.

Bit 3 OPM: One-pulse mode

0: Counter is not stopped on the update event

1: Counter stops counting on the next update event (clearing the CEN bit).

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

0: Any of the following events generates an update interrupt if enabled:

– Counter overflow

– Setting the UG bit

1: Only counter overflow generates an update interrupt if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable update event (UEV) generation.

0: UEV enabled. An UEV is generated by one of the following events:

– Counter overflow

– Setting the UG bit

Buffered registers are then loaded with their preload values.

1: UEV disabled. No UEV is generated, shadow registers keep their value (ARR, PSC, CCRx). The counter and the prescaler are reinitialized if the UG bit is set.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

CEN is cleared automatically in one-pulse mode, when an update event occurs.

19.4.2 TIM9/12 slave mode control register (TIMx_SMCR)

Address offset: 0x08

Reset value: 0x0000

1514131211109876543210
ReservedMSMTS[2:0]Res.SMS[2:0]
rwrwrwrwrwrwrw

Bits 15:8 Reserved, must be kept at reset value.

Bit 7 MSM: Master/Slave mode

0: No action

1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect synchronization between the current timer and its slaves (through TRGO). It is useful in order to synchronize several timers on a single external event.

Bits 6:4 TS: Trigger selection

This bit field selects the trigger input to be used to synchronize the counter.

000: Internal Trigger 0 (ITR0)

001: Internal Trigger 1 (ITR1)

010: Internal Trigger 2 (ITR2)

011: Internal Trigger 3 (ITR3)

100: TI1 Edge Detector (TI1F_ED)

101: Filtered Timer Input 1 (TI1FP1)

110: Filtered Timer Input 2 (TI2FP2)

111: Reserved.

See Table 101 for more details on the meaning of ITRx for each timer.

Note: These bits must be changed only when they are not used (e.g. when SMS='000') to avoid wrong edge detections at the transition.

Bit 3 Reserved, must be kept at reset value.

Bits 2:0 SMS: Slave mode selection

When external signals are selected, the active edge of the trigger signal (TRGI) is linked to the polarity selected on the external input (see Input control register and Control register descriptions).

000: Slave mode disabled - if CEN = 1 then the prescaler is clocked directly by the internal clock

001: Reserved

010: Reserved

011: Reserved

100: Reset mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter and generates an update of the registers

101: Gated mode - The counter clock is enabled when the trigger input (TRGI) is high. The counter stops (but is not reset) as soon as the trigger becomes low. Counter starts and stops are both controlled

110: Trigger mode - The counter starts on a rising edge of the trigger TRGI (but it is not reset). Only the start of the counter is controlled

111: External clock mode 1 - Rising edges of the selected trigger (TRGI) clock the counter

Note: The Gated mode must not be used if TI1F_ED is selected as the trigger input (TS='100'). Indeed, TI1F_ED outputs 1 pulse for each transition on TI1F, whereas the Gated mode checks the level of the trigger signal.

Note: The clock of the slave timer must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Table 101. TIMx internal trigger connection

Slave TIMITR0 (TS = 000)ITR1 (TS = 001)ITR2 (TS = 010)ITR3 (TS = 011)
TIM9TIM2_TRGOTIM3_TRGOTIM10_OCTIM11_OC
TIM12TIM4_TRGOTIM5_TRGOTIM13_OCTIM14_OC

19.4.3 TIM9/12 Interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
ReservedTIEResCC2IECC1IEUIE
rwrwrwrw

Bits 15:7 Reserved, must be kept at reset value.

Bit 6 TIE: Trigger interrupt enable

0: Trigger interrupt disabled.

1: Trigger interrupt enabled.

Bit 5:3 Reserved, must be kept at reset value.

19.4.4 TIM9/12 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
ReservedCC2OFCC1OFReservedTIFReservedCC2IFCC1IFUIF
rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0

Bits 15:11 Reserved, must be kept at reset value.

Bit 10 CC2OF: Capture/compare 2 overcapture flag
refer to CC1OF description

Bit 9 CC1OF: Capture/Compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.

0: No overcapture has been detected.

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bits 8:7 Reserved, must be kept at reset value.

Bit 6 TIF: Trigger interrupt flag

This flag is set by hardware on trigger event (active edge detected on TRGI input when the slave mode controller is enabled in all modes but gated mode. It is set when the counter starts or stops when gated mode is selected. It is cleared by software.

0: No trigger event occurred.

1: Trigger interrupt pending.

Bits 5:3 Reserved, must be kept at reset value.

Bit 2 CC2IF: Capture/Compare 2 interrupt flag
refer to CC1IF description

Bit 1 CC1IF: Capture/compare 1 interrupt flag

If channel CC1 is configured as output:

This flag is set by hardware when the counter matches the compare value. It is cleared by software.

0: No match.

1: The content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register. When the contents of TIMx_CCR1 are greater than the contents of TIMx_ARR, the CC1IF bit goes high on the counter overflow.

If channel CC1 is configured as input:

This bit is set by hardware on a capture. It is cleared by software or by reading the TIMx_CCR1 register.

0: No input capture occurred.

1: The counter value has been captured in TIMx_CCR1 register (an edge has been detected on IC1 which matches the selected polarity).

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

19.4.5 TIM9/12 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
ReservedTGReservedCC2GCC1GUG
wwww

Bits 15:7 Reserved, must be kept at reset value.

Bit 6 TG: Trigger generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: The TIF flag is set in the TIMx_SR register. Related interrupt can occur if enabled

Bits 5:3 Reserved, must be kept at reset value.

Bit 2 CC2G: Capture/compare 2 generation

refer to CC1G description

Bit 1 CC1G: Capture/compare 1 generation

This bit is set by software to generate an event, it is automatically cleared by hardware.

0: No action

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

the CC1IF flag is set, the corresponding interrupt is sent if enabled.

If channel CC1 is configured as input:

The current counter value is captured in the TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: Re-initializes the counter and generates an update of the registers. The prescaler counter is also cleared and the prescaler ratio is not affected. The counter is cleared.

19.4.6 TIM9/12 capture/compare mode register 1 (TIMx_CCMR1)

Address offset: 0x18

Reset value: 0x0000

The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits in this register have different functions in input and output modes. For a given bit, OCxx describes its function when the channel is configured in output mode, ICxx describes its function when the channel is configured in input mode. Take care that the same bit can have different meanings for the input stage and the output stage.

1514131211109876543210
Res.OC2M[2:0]OC2PEOC2FECC2S[1:0]Res.OC1M[2:0]OC1PEOC1FECC1S[1:0]
IC2F[3:0]IC2PSC[1:0]IC1F[3:0]IC1PSC[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode

Bit 15 Reserved, must be kept at reset value.

Bits 14:12 OC2M[2:0]: Output compare 2 mode

Bit 11 OC2PE: Output compare 2 preload enable

Bit 10 OC2FE: Output compare 2 fast enable

Bits 9:8 CC2S[1:0]: Capture/Compare 2 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode works only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: The CC2S bits are writable only when the channel is OFF (CC2E = 0 in TIMx_CCER).

Bit 7 Reserved, must be kept at reset value.

Bits 6:4 OC1M: Output compare 1 mode

These bits define the behavior of the output reference signal OC1REF from which OC1 and OC1N are derived. OC1REF is active high whereas the active levels of OC1 and OC1N depend on the CC1P and CC1NP bits, respectively.

000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.(this mode is used to generate a timing base).

001: Set channel 1 to active level on match. The OC1REF signal is forced high when the TIMx_CNT counter matches the capture/compare register 1 (TIMx_CCR1).

010: Set channel 1 to inactive level on match. The OC1REF signal is forced low when the TIMx_CNT counter matches the capture/compare register 1 (TIMx_CCR1).

011: Toggle - OC1REF toggles when TIMx_CNT=TIMx_CCR1

100: Force inactive level - OC1REF is forced low

101: Force active level - OC1REF is forced high

110: PWM mode 1 - In upcounting, channel 1 is active as long as TIMx_CNT<TIMx_CCR1 else it is inactive. In downcounting, channel 1 is inactive (OC1REF='0') as long as TIMx_CNT>TIMx_CCR1, else it is active (OC1REF='1')

111: PWM mode 2 - In upcounting, channel 1 is inactive as long as TIMx_CNT<TIMx_CCR1 else it is active. In downcounting, channel 1 is active as long as TIMx_CNT>TIMx_CCR1 else it is inactive.

Note: In PWM mode 1 or 2, the OCREF level changes only when the result of the comparison changes or when the output compare mode switches from “frozen” mode to “PWM” mode.

Bit 3 OC1PE: Output compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken into account immediately

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded into the active register at each update event

Bit 2 OC1FE: Output compare 1 fast enable

This bit is used to accelerate the effect of an event on the trigger in input on the CC output.
0: CC1 behaves normally depending on the counter and CCR1 values even when the trigger is ON. The minimum delay to activate the CC1 output when an edge occurs on the trigger input is 5 clock cycles

1: An active edge on the trigger input acts like a compare match on the CC1 output. Then, OC is set to the compare level independently of the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OC1FE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S: Capture/Compare 1 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: CC1 channel is configured as input, IC1 is mapped on TI2

11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode works only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: The CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

Input capture mode

Bits 15:12 IC2F: Input capture 2 filter

Bits 11:10 IC2PSC[1:0]: Input capture 2 prescaler

Bits 9:8 CC2S: Capture/compare 2 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode works only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: The CC2S bits are writable only when the channel is OFF (CC2E = 0 in TIMx_CCER).

Bits 7:4 IC1F: Input capture 1 filter

This bitfield defines the frequency used to sample the TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, sampling is done at \(f_{DTS}\)

0001: \(f_{SAMPLING}=f_{CK\_INT}\), N=2

0010: \(f_{SAMPLING}=f_{CK\_INT}\), N=4

0011: \(f_{SAMPLING}=f_{CK\_INT}\), N=8

0100: \(f_{SAMPLING}=f_{DTS}/2\), N=6

0101: \(f_{SAMPLING}=f_{DTS}/2\), N=8

0110: \(f_{SAMPLING}=f_{DTS}/4\), N=6

0111: \(f_{SAMPLING}=f_{DTS}/4\), N=8

1000: \(f_{SAMPLING}=f_{DTS}/8\), N=6

1001: \(f_{SAMPLING}=f_{DTS}/8\), N=8

1010: \(f_{SAMPLING}=f_{DTS}/16\), N=5

1011: \(f_{SAMPLING}=f_{DTS}/16\), N=6

1100: \(f_{SAMPLING}=f_{DTS}/16\), N=8

1101: \(f_{SAMPLING}=f_{DTS}/32\), N=5

1110: \(f_{SAMPLING}=f_{DTS}/32\), N=6

1111: \(f_{SAMPLING}=f_{DTS}/32\), N=8

Bits 3:2 IC1PSC: Input capture 1 prescaler

This bitfield defines the ratio of the prescaler acting on the CC1 input (IC1).

The prescaler is reset as soon as CC1E='0' (TIMx_CCER register).

00: no prescaler, capture is done each time an edge is detected on the capture input

01: capture is done once every 2 events

10: capture is done once every 4 events

11: capture is done once every 8 events

Bits 1:0 CC1S: Capture/Compare 1 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: CC1 channel is configured as input, IC1 is mapped on TI2

11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: The CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

19.4.7 TIM9/12 capture/compare enable register (TIMx_CCER)

Address offset: 0x20

Reset value: 0x0000

1514131211109876543210
ReservedCC2NPRes.CC2PCC2ECC1NPRes.CC1PCC1E
rwrwrwrwrwrw

Bits 15:8 Reserved, must be kept at reset value.

Bit 7 CC2NP: Capture/Compare 2 output Polarity
refer to CC1NP description

Bits 6 Reserved, must be kept at reset value.

Bit 5 CC2P: Capture/Compare 2 output Polarity
refer to CC1P description

Bit 4 CC2E: Capture/Compare 2 output enable
refer to CC1E description

Bit 3 CC1NP: Capture/Compare 1 complementary output Polarity
CC1 channel configured as output: CC1NP must be kept cleared
CC1 channel configured as input: CC1NP is used in conjunction with CC1P to define TI1FP1/TI2FP1 polarity (refer to CC1P description).

Bit 2 Reserved, must be kept at reset value.

Bit 1 CC1P: Capture/Compare 1 output Polarity.

CC1 channel configured as output:

0: OC1 active high.

1: OC1 active low.

CC1 channel configured as input:

CC1NP/CC1P bits select TI1FP1 and TI2FP1 polarity for trigger or capture operations.

00: noninverted/rising edge

Circuit is sensitive to TIxFP1 rising edge (capture, trigger in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger in gated mode, encoder mode).

01: inverted/falling edge

Circuit is sensitive to TIxFP1 falling edge (capture, trigger in reset, external clock or trigger mode), TIxFP1 is inverted (trigger in gated mode, encoder mode).

10: reserved, do not use this configuration.

Note: 11: noninverted/both edges

Circuit is sensitive to both TIxFP1 rising and falling edges (capture, trigger in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger in gated mode). This configuration must not be used for encoder mode.

Bit 0 CC1E: Capture/Compare 1 output enable.

CC1 channel configured as output:

0: Off - OC1 is not active.

1: On - OC1 signal is output on the corresponding output pin.

CC1 channel configured as input:

This bit determines if a capture of the counter value can actually be done into the input capture/compare register 1 (TIMx_CCR1) or not.

0: Capture disabled.

1: Capture enabled.

Table 102. Output control bit for standard OCx channels

CCxE bitOCx output state
0Output disabled (OCx='0', OCx_EN='0')
1OCx=OCxREF + Polarity, OCx_EN='1'

Note: The states of the external I/O pins connected to the standard OCx channels depend on the state of the OCx channel and on the GPIO registers.

19.4.8 TIM9/12 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000

1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CNT[15:0]: Counter value

19.4.9 TIM9/12 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency CK_CNT is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

19.4.10 TIM9/12 auto-reload register (TIMx_ARR)

Address offset: 0x2C

Reset value: 0xFFFF

1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 ARR[15:0]: Auto-reload value

ARR is the value to be loaded into the actual auto-reload register.

Refer to the Section 19.3.1: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

19.4.11 TIM9/12 capture/compare register 1 (TIMx_CCR1)

Address offset: 0x34

Reset value: 0x0000

1514131211109876543210
CCR1[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR1[15:0]: Capture/Compare 1 value

If channel CC1 is configured as output:

CCR1 is the value to be loaded into the actual capture/compare 1 register (preload value). It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (OC1PE bit). Else the preload value is copied into the active capture/compare 1 register when an update event occurs.

The active capture/compare register contains the value to be compared to the TIMx_CNT counter and signaled on the OC1 output.

If channel CC1 is configured as input:

CCR1 is the counter value transferred by the last input capture 1 event (IC1). The TIMx_CCR1 register is read-only and cannot be programmed.

19.4.12 TIM9/12 capture/compare register 2 (TIMx_CCR2)

Address offset: 0x38

Reset value: 0x0000

1514131211109876543210
CCR2[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR2[15:0]: Capture/Compare 2 value

If channel CC2 is configured as output:

CCR2 is the value to be loaded into the actual capture/compare 2 register (preload value). It is loaded permanently if the preload feature is not selected in the TIMx_CCMR2 register (OC2PE bit). Else the preload value is copied into the active capture/compare 2 register when an update event occurs.

The active capture/compare register contains the value to be compared to the TIMx_CNT counter and signalled on the OC2 output.

If channel CC2 is configured as input:

CCR2 is the counter value transferred by the last input capture 2 event (IC2). The TIMx_CCR2 register is read-only and cannot be programmed.

19.4.13 TIM9/12 register map

TIM9/12 registers are mapped as 16-bit addressable registers as described below. The reserved memory areas are highlighted in gray in the table.

Table 103. TIM9/12 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1
Reset value
ReservedCKD
[1:0]
ARPEReservedOPMURSUDISCEN
0000000
0x08TIMx_SMCR
Reset value
ReservedMSMTS[2:0]ReservedSMS[2:0]
00000000000
0x0CTIMx_DIER
Reset value
ReservedTIEReservedCC2IECC1IEUIE
000000
0x10TIMx_SR
Reset value
ReservedCC2OFCC1OFReservedTIFReservedCC2IFCC1IFUIF
0000000
0x14TIMx_EGR
Reset value
ReservedTGReservedCC2GCC1GUG
000000
0x18TIMx_CCMR1
Output compare mode
Reset value
ReservedOC2M
[2:0]
OC2PEOC2FECC2S
[1:0]
ReservedOC1M
[2:0]
OC1PEOC1FECC1S
[1:0]
0000000000000
TIMx_CCMR1
Input capture mode
Reset value
ReservedIC2F[3:0]IC2PSC
[1:0]
CC2S
[1:0]
IC1F[3:0]IC1PSC
[1:0]
CC1S
[1:0]
0000000000000
0x1CReserved
0x20TIMx_CCER
Reset value
ReservedCC2NPReservedCC2PCC2ECC1NPReservedCC1PCC1E
000000
0x24TIMx_CNT
Reset value
ReservedCNT[15:0]
0000000000000000
0x28TIMx_PSC
Reset value
ReservedPSC[15:0]
0000000000000000
0x2CTIMx_ARR
Reset value
ReservedARR[15:0]
0000000000000000
0x30Reserved
0x34TIMx_CCR1
Reset value
ReservedCCR1[15:0]
0000000000000000

Table 103. TIM9/12 register map and reset values (continued)

OffsetRegister313029282726252423222120191817161514131211109876543210
0x38TIMx_CCR2ReservedCCR2[15:0]
Reset value0000000000000000
0x3C to 0x4CReserved

Refer to Section 2.3: Memory map for the register boundary addresses.

19.5 TIM10/11/13/14 registers

The peripheral registers have to be written by half-words (16 bits) or words (32 bits). Read accesses can be done by bytes (8 bits), half-words (16 bits) or words (32 bits).

19.5.1 TIM10/11/13/14 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
ReservedCKD[1:0]ARPEReservedOPMURSUDISCEN
rwrwrwrwrwrwrw

Bits 15:10 Reserved, must be kept at reset value.

Bits 9:8 CKD: Clock division

This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and sampling clock used by the digital filters (Tlx),

00: \(t_{DTS} = t_{CK\_INT}\)

01: \(t_{DTS} = 2 \times t_{CK\_INT}\)

10: \(t_{DTS} = 4 \times t_{CK\_INT}\)

11: Reserved

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered

1: TIMx_ARR register is buffered

Bits 6:4 Reserved, must be kept at reset value.

Bit 3 OPM: One-pulse mode

0: Counter is not stopped on the update event

1: Counter stops counting on the next update event (clearing the CEN bit).

Bit 2 URS: Update request source

This bit is set and cleared by software to select the update interrupt (UEV) sources.

0: Any of the following events generate an UEV if enabled:

– Counter overflow

– Setting the UG bit

1: Only counter overflow generates an UEV if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable update interrupt (UEV) event generation.

0: UEV enabled. An UEV is generated by one of the following events:

– Counter overflow

– Setting the UG bit.

Buffered registers are then loaded with their preload values.

1: UEV disabled. No UEV is generated, shadow registers keep their value (ARR, PSC, CCRx). The counter and the prescaler are reinitialized if the UG bit is set.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

19.5.2 TIM10/11/13/14 Interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
ReservedCC1IEUIE
rwrw

Bits 15:2 Reserved, must be kept at reset value.

Bit 1 CC1IE: Capture/Compare 1 interrupt enable

0: CC1 interrupt disabled

1: CC1 interrupt enabled

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled

1: Update interrupt enabled

19.5.3 TIM10/11/13/14 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
ReservedCC1OFReservedCC1IFUIF
rc_w0rc_w0rc_w0

Bits 15:10 Reserved, must be kept at reset value.

Bit 9 CC1OF: Capture/Compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.

0: No overcapture has been detected.

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bits 8:2 Reserved, must be kept at reset value.

Bit 1 CC1IF: Capture/compare 1 interrupt flag

If channel CC1 is configured as output:

This flag is set by hardware when the counter matches the compare value. It is cleared by software.

0: No match.

1: The content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register.

When the contents of TIMx_CCR1 are greater than the contents of TIMx_ARR, the CC1IF bit goes high on the counter overflow.

If channel CC1 is configured as input:

This bit is set by hardware on a capture. It is cleared by software or by reading the TIMx_CCR1 register.

0: No input capture occurred.

1: The counter value has been captured in TIMx_CCR1 register (an edge has been detected on IC1 which matches the selected polarity).

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

19.5.4 TIM10/11/13/14 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
ReservedCC1GUG
ww

Bits 15:2 Reserved, must be kept at reset value.

Bit 1 CC1G: Capture/compare 1 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

CC1IF flag is set, Corresponding interrupt or is sent if enabled.

If channel CC1 is configured as input:

The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: Re-initialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected). The counter is cleared.

19.5.5 TIM10/11/13/14 capture/compare mode register 1 (TIMx_CCMR1)

Address offset: 0x18

Reset value: 0x0000

The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function in input and in output mode. For a given bit, OCxx describes its function when the channel is configured in output, ICxx describes its function when the channel is configured in input. So take care that the same bit can have a different meaning for the input stage and for the output stage.

1514131211109876543210
ReservedOC1M[2:0]OC1PEOC1FECC1S[1:0]
ReservedIC1F[3:0]IC1PSC[1:0]
rwrwrwrwrwrw

Output compare mode

Bits 15:7 Reserved, must be kept at reset value.

Bits 6:4 OC1M: Output compare 1 mode

These bits define the behavior of the output reference signal OC1REF from which OC1 is derived. OC1REF is active high whereas OC1 active level depends on CC1P bit.

000: Frozen. The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.

001: Set channel 1 to active level on match. OC1REF signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

010: Set channel 1 to inactive level on match. OC1REF signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

011: Toggle - OC1REF toggles when TIMx_CNT = TIMx_CCR1.

100: Force inactive level - OC1REF is forced low.

101: Force active level - OC1REF is forced high.

110: PWM mode 1 - Channel 1 is active as long as TIMx_CNT < TIMx_CCR1 else inactive.

111: PWM mode 2 - Channel 1 is inactive as long as TIMx_CNT < TIMx_CCR1 else active.

Note: In PWM mode 1 or 2, the OCREF level changes when the result of the comparison changes or when the output compare mode switches from frozen to PWM mode.

Bit 3 OC1PE: Output compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.

Bit 2 OC1FE: Output compare 1 fast enable

This bit is used to accelerate the effect of an event on the trigger input on the CC output.

0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.

1: An active edge on the trigger input acts like a compare match on CC1 output. OC is then set to the compare level independently of the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OC1FE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S: Capture/Compare 1 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output.

01: CC1 channel is configured as input, IC1 is mapped on TI1.

10:

11:

Note: CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

Input capture mode

Bits 15:8 Reserved, must be kept at reset value.

Bits 7:4 IC1F: Input capture 1 filter

This bit-field defines the frequency used to sample TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, sampling is done at fDTS

0001: fSAMPLING=fCK_INT, N=2

0010: fSAMPLING=fCK_INT, N=4

0011: fSAMPLING=fCK_INT, N=8

0100: fSAMPLING=fDTS/2, N=6

0101: fSAMPLING=fDTS/2, N=8

0110: fSAMPLING=fDTS/4, N=6

0111: fSAMPLING=fDTS/4, N=8

1000: fSAMPLING=fDTS/8, N=6

1001: fSAMPLING=fDTS/8, N=8

1010: fSAMPLING=fDTS/16, N=5

1011: fSAMPLING=fDTS/16, N=6

1100: fSAMPLING=fDTS/16, N=8

1101: fSAMPLING=fDTS/32, N=5

1110: fSAMPLING=fDTS/32, N=6

1111: fSAMPLING=fDTS/32, N=8

Bits 3:2 IC1PSC: Input capture 1 prescaler

This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).

The prescaler is reset as soon as CC1E=’0’ (TIMx_CCER register).

00: no prescaler, capture is done each time an edge is detected on the capture input

01: capture is done once every 2 events

10: capture is done once every 4 events

11: capture is done once every 8 events

Bits 1:0 CC1S: Capture/Compare 1 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: Reserved

11: Reserved

Note: CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

19.5.6 TIM10/11/13/14 capture/compare enable register (TIMx_CCER)

Address offset: 0x20

Reset value: 0x0000

1514131211109876543210
ReservedCC1NPRes.CC1PCC1E
rwrwrw

Bits 15:4 Reserved, must be kept at reset value.

Bit 3 CC1NP: Capture/Compare 1 complementary output Polarity.

CC1 channel configured as output: CC1NP must be kept cleared.

CC1 channel configured as input: CC1NP bit is used in conjunction with CC1P to define TI1FP1 polarity (refer to CC1P description).

Bit 2 Reserved, must be kept at reset value.

Bit 1 CC1P: Capture/Compare 1 output Polarity.

CC1 channel configured as output:

0: OC1 active high

1: OC1 active low

CC1 channel configured as input:

The CC1P bit selects TI1FP1 and TI2FP1 polarity for trigger or capture operations.

00: noninverted/rising edge

Circuit is sensitive to TI1FP1 rising edge (capture mode), TI1FP1 is not inverted.

01: inverted/falling edge

Circuit is sensitive to TI1FP1 falling edge (capture mode), TI1FP1 is inverted.

10: reserved, do not use this configuration.

11: noninverted/both edges

Circuit is sensitive to both TI1FP1 rising and falling edges (capture mode), TI1FP1 is not inverted.

Bit 0 CC1E: Capture/Compare 1 output enable.

CC1 channel configured as output:

0: Off - OC1 is not active

1: On - OC1 signal is output on the corresponding output pin

CC1 channel configured as input:

This bit determines if a capture of the counter value can actually be done into the input capture/compare register 1 (TIMx_CCR1) or not.

0: Capture disabled

1: Capture enabled

Table 104. Output control bit for standard OCx channels

CCxE bitOCx output state
0Output Disabled (OCx='0', OCx_EN='0')
1OCx=OCxREF + Polarity, OCx_EN='1'

Note: The state of the external I/O pins connected to the standard OCx channels depends on the OCx channel state and the GPIO registers.

19.5.7 TIM10/11/13/14 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000

1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CNT[15:0]: Counter value

19.5.8 TIM10/11/13/14 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency CK_CNT is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

19.5.9 TIM10/11/13/14 auto-reload register (TIMx_ARR)

Address offset: 0x2C

Reset value: 0xFFFF

1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 ARR[15:0]: Auto-reload value

ARR is the value to be loaded in the actual auto-reload register.

Refer to Section 19.3.1: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

19.5.10 TIM10/11/13/14 capture/compare register 1 (TIMx_CCR1)

Address offset: 0x34

Reset value: 0x0000

1514131211109876543210
CCR1[15:0]
rw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/rorw/ro

Bits 15:0 CCR1[15:0]: Capture/Compare 1 value

If channel CC1 is configured as output:

CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on OC1 output.

If channel CC1 is configured as input:

CCR1 is the counter value transferred by the last input capture 1 event (IC1). The TIMx_CCR1 register is read-only and cannot be programmed.

19.5.11 TIM11 option register 1 (TIM11_OR)

Address offset: 0x50

Reset value: 0x0000

1514131211109876543210
ReservedTI1_RMP[1:0]
rw

Bits 15:2 Reserved, must be kept at reset value.

Bits 1:0 TI1_RMP[1:0]: TIM11 Input 1 remapping capability

Set and cleared by software.

00,01,11: TIM11 Channel1 is connected to the GPIO (refer to the Alternate function mapping table in the datasheets).

10: HSE_RTC clock (HSE divided by programmable prescaler) is connected to the TIM11_CH1 input for measurement purposes

19.5.12 TIM10/11/13/14 register map

TIMx registers are mapped as 16-bit addressable registers as described in the table below.

Table 105. TIM10/11/13/14 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1ReservedCKD [1:0]ARPEReserve dOPMURSUDISCEN
Reset value00000000000
0x08TIMx_SMCRReserved
Reset value
0x0CTIMx_DIERReservedCC1IEUIE
Reset value00
0x10TIMx_SRReservedCC1OFReservedCC1IFUIF
Reset value0000
0x14TIMx_EGRReservedCC1GUG
Reset value00
0x18TIMx_CCMR1
Output compare mode
ReservedOC1M [2:0]OC1PEOC1FECC1S [1:0]
Reset value000000000
TIMx_CCMR1
Input capture mode
ReservedIC1F[3:0]IC1 PSC [1:0]CC1S [1:0]
Reset value000000000
0x1CReserved
0x20TIMx_CCERReservedCC1NPReservedCC1PCC1E
Reset value00000
0x24TIMx_CNTReservedCNT[15:0]
Reset value000000000000000000000
0x28TIMx_PSCReservedPSC[15:0]
Reset value000000000000000000000
0x2CTIMx_ARRReservedARR[15:0]
Reset value000000000000000000000
0x30Reserved
0x34TIMx_CCR1ReservedCCR1[15:0]
Reset value000000000000000000000
0x38 to 0x4CReserved

Table 105. TIM10/11/13/14 register map and reset values (continued)

OffsetRegister313029282726252423222120191817161514131211109876543210
0x50TIMx_ORReservedTIM_RMP
Reset value00

Refer to Section 2.3: Memory map for the register boundary addresses.