20. Basic timers (TIM6 and TIM7)

This section applies to the whole STM32F4xx family, unless otherwise specified.

20.1 TIM6 and TIM7 introduction

The basic timers TIM6 and TIM7 consist of a 16-bit auto-reload counter driven by a programmable prescaler.

They may be used as generic timers for time-base generation but they are also specifically used to drive the digital-to-analog converter (DAC). In fact, the timers are internally connected to the DAC and are able to drive it through their trigger outputs.

The timers are completely independent, and do not share any resources.

20.2 TIM6 and TIM7 main features

Basic timer (TIM6 and TIM7) features include:

Figure 203. Basic timer block diagram

Block diagram of a basic timer showing the internal components and signal flow. The diagram includes a Trigger controller receiving TIMxCLK from RCC and outputting TRGO to DAC. A Controller block is connected to the Trigger controller. The PSC Prescaler receives CK_PSC and outputs CK_CNT to the CNT COUNTER. The CNT COUNTER outputs an update event (U) to the Auto-reload Register. The Auto-reload Register outputs Stop, Clear or up signals to the CNT COUNTER and an interrupt & DMA output (UI). A Flag block indicates that preload registers are transferred to active registers on the U event according to control bits.

The diagram illustrates the internal architecture of a basic timer. At the top, a 'Trigger controller' block receives 'TIMxCLK from RCC' and an 'Internal clock (CK_INT)'. It outputs a 'TRGO' signal 'to DAC' and provides 'Reset, Enable, Count' control signals to a 'Controller' block. Below this, the 'PSC Prescaler' block takes 'CK_PSC' as input and outputs 'CK_CNT' to the 'CNT COUNTER' block. The 'CNT COUNTER' block outputs an update event 'U' to the 'Auto-reload Register' block. The 'Auto-reload Register' block outputs 'Stop, Clear or up' signals back to the 'CNT COUNTER' and an interrupt & DMA output 'UI'. A 'Flag' block is shown with the text 'Preload registers transferred to active registers on U event according to control bit'. A legend at the bottom left defines the symbols: a box for 'Flag', a chevron for 'event', and a lightning bolt for 'interrupt & DMA output'. The diagram is labeled 'ai14749b' in the bottom right corner.

Block diagram of a basic timer showing the internal components and signal flow. The diagram includes a Trigger controller receiving TIMxCLK from RCC and outputting TRGO to DAC. A Controller block is connected to the Trigger controller. The PSC Prescaler receives CK_PSC and outputs CK_CNT to the CNT COUNTER. The CNT COUNTER outputs an update event (U) to the Auto-reload Register. The Auto-reload Register outputs Stop, Clear or up signals to the CNT COUNTER and an interrupt & DMA output (UI). A Flag block indicates that preload registers are transferred to active registers on the U event according to control bits.

20.3 TIM6 and TIM7 functional description

20.3.1 Time-base unit

The main block of the programmable timer is a 16-bit upcounter with its related auto-reload register. The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. The preload register is accessed each time an attempt is made to write or read the auto-reload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the auto-reload preload enable bit (ARPE) in the TIMx_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in the TIMx_CR1 register is set.

Note that the actual counter enable signal CNT_EN is set 1 clock cycle after CEN.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as the TIMx_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 204 and Figure 205 give some examples of the counter behavior when the prescaler ratio is changed on the fly.

Figure 204. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CNT_EN, Timerclock, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

The diagram illustrates the timing of a prescaler division change from 1 to 2. The CK_PSC signal is a continuous clock. The CNT_EN signal is high during the active period. The Timerclock = CK_CNT signal is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. The Update event (UEV) signal is high at the end of each counter overflow. The Prescaler control register is set to 0 initially and then changes to 1. The Prescaler buffer is set to 0 initially and then changes to 1. The Prescaler counter is set to 0 initially and then counts 0, 1, 0, 1, 0, 1, 0, 1. A write to the TIMx_PSC register is indicated by an arrow pointing to the Prescaler control register transition.

SignalInitial StateFinal StateValues/States
CK_PSCLowHighContinuous clock
CNT_ENLowHighActive high
Timerclock = CK_CNTLowHighDerived from CK_PSC
Counter registerF703F7, F8, F9, FA, FB, FC, 00, 01, 02, 03
Update event (UEV)LowHighHigh at overflow
Prescaler control register010, 1
Prescaler buffer010, 1
Prescaler counter010, 1, 0, 1, 0, 1, 0, 1

MS31076V3

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CNT_EN, Timerclock, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

Figure 205. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CNT_EN, Timerclock, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

The diagram illustrates the timing of a prescaler division change from 1 to 4. The CK_PSC signal is a continuous clock. The CNT_EN signal is high during the active period. The Timerclock = CK_CNT signal is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. The Update event (UEV) signal is high at the end of each counter overflow. The Prescaler control register is set to 0 initially and then changes to 3. The Prescaler buffer is set to 0 initially and then changes to 3. The Prescaler counter is set to 0 initially and then counts 0, 1, 2, 3, 0, 1, 2, 3. A write to the TIMx_PSC register is indicated by an arrow pointing to the Prescaler control register transition.

SignalInitial StateFinal StateValues/States
CK_PSCLowHighContinuous clock
CNT_ENLowHighActive high
Timerclock = CK_CNTLowHighDerived from CK_PSC
Counter registerF701F7, F8, F9, FA, FB, FC, 00, 01
Update event (UEV)LowHighHigh at overflow
Prescaler control register030, 3
Prescaler buffer030, 3
Prescaler counter030, 1, 2, 3, 0, 1, 2, 3

MS31077V3

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CNT_EN, Timerclock, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

20.3.2 Counting mode

The counter counts from 0 to the auto-reload value (contents of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

An update event can be generate at each counter overflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller).

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been written to 0, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIMx_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).

When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.

Figure 206. Counter timing diagram, internal clock divided by 1

Timing diagram for a counter in counting mode with internal clock divided by 1. The diagram shows the relationship between CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

The diagram illustrates the timing of a counter in counting mode. The internal clock (CK_INT) is divided by 1 to drive the timer clock (CK_CNT). The counter register counts from 31 to 00, then wraps back to 00. A counter overflow occurs when the counter reaches 00. An update event (UEV) is generated at the overflow. The update interrupt flag (UIF) is set at the update event.

The counter register values are shown as follows:

3132333435360001020304050607

MS37364V1

Timing diagram for a counter in counting mode with internal clock divided by 1. The diagram shows the relationship between CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 207. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_INT signal is a continuous square wave. The CNT_EN signal is an active-high enable signal that starts at the first rising edge of CK_INT. The Timerclock = CK_CNT signal is a square wave with a 50% duty cycle, where one full cycle of CK_CNT corresponds to two cycles of CK_INT. The Counter register shows the sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, 0003. A counter overflow occurs when the register value wraps from 0036 to 0000. This event triggers an Update event (UEV) pulse and sets the Update interrupt flag (UIF). The reference code MS35835V1 is located in the bottom right corner.

Timing diagram for counter with internal clock divided by 2. Shows CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 208. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram shows the counter operation with the internal clock divided by 4. CK_INT is a continuous square wave. CNT_EN is an active-high enable signal. The Timerclock = CK_CNT signal has a 25% duty cycle, with one full cycle of CK_CNT corresponding to four cycles of CK_INT. The Counter register values shown are 0035, 0036, 0000, and 0001. Overflow occurs at the transition from 0036 to 0000, generating a UEV pulse and setting the UIF. The reference code MSv37301V1 is in the bottom right corner.

Timing diagram for counter with internal clock divided by 4. Shows CK_INT, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 209. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows CK_INT, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram depicts the counter operation with an arbitrary division factor N. CK_INT is a continuous square wave. The Timerclock = CK_CNT signal has a variable duty cycle. The Counter register shows values 1F, 20, and 00. Overflow occurs when the register value wraps from 1F to 20, which triggers a UEV pulse and sets the UIF. The reference code MSv37302V1 is located in the bottom right corner.

Timing diagram for counter with internal clock divided by N. Shows CK_INT, Timerclock = CK_CNT, Counter register (1F to 00), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 210. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Timing diagram for ARPE=0 showing counter overflow and update event.

This timing diagram illustrates the behavior of a counter when ARPE=0. The signals shown are:

MSv37303V1

Timing diagram for ARPE=0 showing counter overflow and update event.

Figure 211. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Timing diagram for ARPE=1 showing counter overflow and update event with preloaded ARR.

This timing diagram illustrates the behavior of a counter when ARPE=1. The signals shown are:

MSv37304V1

Timing diagram for ARPE=1 showing counter overflow and update event with preloaded ARR.

20.3.3 Clock source

The counter clock is provided by the Internal clock (CK_INT) source.

The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 212 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 212. Control circuit in normal mode, internal clock divided by 1

Timing diagram for TIM6/TIM7 control circuit in normal mode. It shows the relationship between the Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock (CK_CNT = CK_PSC), and the Counter register. The counter register is shown as a 32-bit register with bits 31 down to 0. The diagram illustrates how the counter clock is derived from the internal clock and how the counter register is updated based on the UG and CNT_INIT signals.

MS31085V2

Timing diagram for TIM6/TIM7 control circuit in normal mode. It shows the relationship between the Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock (CK_CNT = CK_PSC), and the Counter register. The counter register is shown as a 32-bit register with bits 31 down to 0. The diagram illustrates how the counter clock is derived from the internal clock and how the counter register is updated based on the UG and CNT_INIT signals.

20.3.4 Debug mode

When the microcontroller enters the debug mode (Cortex®-M4 with FPU core - halted), the TIMx counter either continues to work normally or stops, depending on the DBG_TIMx_STOP configuration bit in the DBG module. For more details, refer to Section 38.16.2: Debug support for timers, watchdog, bxCAN and I2C.

20.4 TIM6 and TIM7 registers

Refer to Section 2.2 for a list of abbreviations used in register descriptions.

The peripheral registers have to be written by half-words (16 bits) or words (32 bits). Read accesses can be done by bytes (8 bits), half-words (16 bits) or words (32 bits).

20.4.1 TIM6 and TIM7 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
ReservedARPEReservedOPMURSUDISCEN
rwrwrwrwrw

Bits 15:8 Reserved, must be kept at reset value.

Bit 7 ARPE: Auto-reload preload enable
0: TIMx_ARR register is not buffered.
1: TIMx_ARR register is buffered.

Bits 6:4 Reserved, must be kept at reset value.

Bit 3 OPM: One-pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the CEN bit).

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

0: Any of the following events generates an update interrupt or DMA request if enabled.

These events can be:

1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

0: UEV enabled. The Update (UEV) event is generated by one of the following events:

Buffered registers are then loaded with their preload values.

1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

Note: Gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

CEN is cleared automatically in one-pulse mode, when an update event occurs.

20.4.2 TIM6 and TIM7 control register 2 (TIMx_CR2)

Address offset: 0x04

Reset value: 0x0000

1514131211109876543210
ReservedMMS[2:0]Reserved
rwrwrw

Bits 15:7 Reserved, must be kept at reset value.

Bits 6:4 MMS[2:0]: Master mode selection

These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:

000: Reset - the UG bit from the TIMx_EGR register is used as a trigger output (TRGO). If reset is generated by the trigger input (slave mode controller configured in reset mode) then the signal on TRGO is delayed compared to the actual reset.

001: Enable - the Counter enable signal, CNT_EN, is used as a trigger output (TRGO). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated by a logic OR between CEN control bit and the trigger input when configured in gated mode.

When the Counter Enable signal is controlled by the trigger input, there is a delay on TRGO, except if the master/slave mode is selected (see the MSM bit description in the TIMx_SMCR register).

010: Update - The update event is selected as a trigger output (TRGO). For instance a master timer can then be used as a prescaler for a slave timer.

Note: The clock of the slave timer and ADC must be enabled prior to receiving events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Bits 3:0 Reserved, must be kept at reset value.

20.4.3 TIM6 and TIM7 DMA/Interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
ReservedUDEReservedUIE
rwrw

Bits 15:9 Reserved, must be kept at reset value.

Bit 8 UDE: Update DMA request enable

0: Update DMA request disabled.

1: Update DMA request enabled.

Bits 7:1 Reserved, must be kept at reset value.

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled.

1: Update interrupt enabled.

20.4.4 TIM6 and TIM7 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
ReservedUIF
rc_w0

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

20.4.5 TIM6 and TIM7 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
ReservedUG
w

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action.

1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).

20.4.6 TIM6 and TIM7 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000

1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CNT[15:0]: Counter value

20.4.7 TIM6 and TIM7 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency CK_CNT is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

20.4.8 TIM6 and TIM7 auto-reload register (TIMx_ARR)

Address offset: 0x2C

Reset value: 0xFFFF

1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 ARR[15:0]: Auto-reload value

ARR is the value to be loaded into the actual auto-reload register.

Refer to Section 20.3.1: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

20.4.9 TIM6 and TIM7 register map

TIMx registers are mapped as 16-bit addressable registers as described in the table below.

Table 106. TIM6 and TIM7 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1ReservedARPEReservedOPMURSUDISCEN
Reset value00000
0x04TIMx_CR2ReservedMMS[2:0]Reserved
Reset value000
0x08Reserved
0x0CTIMx_DIERReservedUDEReservedUIE
Reset value00
0x10TIMx_SRReservedUIF
Reset value0
0x14TIMx_EGRReservedUG
Reset value0
0x18Reserved
0x1CReserved
0x20Reserved
0x24TIMx_CNTReservedCNT[15:0]
Reset value000000000000000000
0x28TIMx_PSCReservedPSC[15:0]
Reset value000000000000000000
0x2CTIMx_ARRReservedARR[15:0]
Reset value111111111111111111

Refer to Section 2.3: Memory map for the register boundary addresses.