44. Basic timers (TIM6/TIM7)

44.1 TIM6/TIM7 introduction

The basic timers TIM6 and TIM7 consist of a 16-bit auto-reload counter driven by a programmable prescaler.

They may be used as generic timers for time base generation but they are also specifically used to drive the digital-to-analog converter (DAC). In fact, the timers are internally connected to the DAC and are able to drive it through their trigger outputs.

The timers are completely independent, and do not share any resources.

44.2 TIM6/TIM7 main features

Basic timer (TIM6/TIM7) features include:

Figure 522. Basic timer block diagram

Block diagram of a basic timer showing the internal components and signal flow. The diagram includes a Trigger controller, Control block, Auto-reload register, PSC prescaler, and CNT counter. Signals include TIMxCLK from RCC, Internal clock (CK_INT), TRGO to DAC, Reset/enable/Count, CK_PSC, CK_CNT, and various events (U, UI).

The diagram illustrates the internal architecture of a basic timer. At the top, the 'Trigger controller' and 'Control' block receive 'Internal clock (CK_INT)' from 'TIMxCLK from RCC'. The 'Trigger controller' outputs 'TRGO' to the DAC and provides 'Reset, enable, Count' signals to the 'Control' block. The 'Control' block also interfaces with the 'Auto-reload register' and 'CNT counter'. The 'Auto-reload register' (shaded as a register) receives 'U' events and provides 'Stop, clear or up' signals to the 'CNT counter'. The 'PSC prescaler' (shaded as a register) takes 'CK_PSC' as input and outputs 'CK_CNT' to the 'CNT counter'. The 'CNT counter' (shaded as a register) outputs 'U' and 'UI' signals, which are marked as events and interrupt/DMA outputs respectively. A legend at the bottom left defines the symbols: a shaded box for 'Reg' (Preload registers transferred to active registers on U event according to control bit), a lightning bolt for 'Event', and a wavy arrow for 'Interrupt & DMA output'. The reference code 'MS33142V1' is located at the bottom right.

Block diagram of a basic timer showing the internal components and signal flow. The diagram includes a Trigger controller, Control block, Auto-reload register, PSC prescaler, and CNT counter. Signals include TIMxCLK from RCC, Internal clock (CK_INT), TRGO to DAC, Reset/enable/Count, CK_PSC, CK_CNT, and various events (U, UI).

44.3 TIM6/TIM7 functional description

44.3.1 Time-base unit

The main block of the programmable timer is a 16-bit upcounter with its related auto-reload register. The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. The preload register is accessed each time an attempt is made to write or read the auto-reload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the auto-reload preload enable bit (ARPE) in the TIMx_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in the TIMx_CR1 register is set.

Note that the actual counter enable signal CNT_EN is set 1 clock cycle after CEN.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as the TIMx_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 523 and Figure 524 give some examples of the counter behavior when the prescaler ratio is changed on the fly.

Figure 523. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for prescaler division change from 1 to 2. It shows CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 2 at the start of the diagram.

The diagram illustrates the timing of a prescaler division change from 1 to 2. The CK_PSC signal is a continuous clock. The CEN signal is active low, starting high and going low at the beginning of the diagram. The Timerclock = CK_CNT signal is a clock derived from CK_PSC, with a period twice that of CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. The Update event (UEV) signal is a pulse at the start of the diagram. The Prescaler control register shows a transition from 0 to 1. The Prescaler buffer shows a transition from 0 to 1. The Prescaler counter shows a sequence of 0, 1, 0, 1, 0, 1, 0, 1. A note 'Write a new value in TIMx_PSC' points to the transition of the Prescaler control register.

MS31076V2

Timing diagram for prescaler division change from 1 to 2. It shows CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 2 at the start of the diagram.

Figure 524. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for prescaler division change from 1 to 4. It shows CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 4 at the start of the diagram.

The diagram illustrates the timing of a prescaler division change from 1 to 4. The CK_PSC signal is a continuous clock. The CEN signal is active low, starting high and going low at the beginning of the diagram. The Timerclock = CK_CNT signal is a clock derived from CK_PSC, with a period four times that of CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. The Update event (UEV) signal is a pulse at the start of the diagram. The Prescaler control register shows a transition from 0 to 3. The Prescaler buffer shows a transition from 0 to 3. The Prescaler counter shows a sequence of 0, 1, 2, 3, 0, 1, 2, 3. A note 'Write a new value in TIMx_PSC' points to the transition of the Prescaler control register.

MS31077V2

Timing diagram for prescaler division change from 1 to 4. It shows CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time. The prescaler division changes from 1 to 4 at the start of the diagram.

44.3.2 Counting mode

The counter counts from 0 to the auto-reload value (contents of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

An update event can be generate at each counter overflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller).

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been cleared, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIMx_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).

When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.

Figure 525. Counter timing diagram, internal clock divided by 1

Timing diagram for a counter with internal clock divided by 1. It shows the relationship between CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

The diagram illustrates the timing of a counter operating in counting mode with an internal clock divided by 1. The signals shown are:

MS31078V2

Timing diagram for a counter with internal clock divided by 1. It shows the relationship between CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register values, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 526. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a continuous square wave. The CNT_EN signal is active low, starting high and transitioning low at the first falling edge of CK_PSC. The Timerclock = CK_CNT signal is a square wave with a period twice that of CK_PSC, starting low. The Counter register shows a sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, and 0003. A counter overflow occurs when the register transitions from 0036 to 0000, which coincides with the falling edge of the Timerclock. This event triggers an Update event (UEV) and sets the Update interrupt flag (UIF). Vertical dashed lines indicate the timing of these events relative to the clock signals.

MS31079V2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0034 to 0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 527. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The CK_PSC signal is a continuous square wave. The CNT_EN signal is active low, starting high and transitioning low at the first falling edge of CK_PSC. The Timerclock = CK_CNT signal is a square wave with a period four times that of CK_PSC, starting low. The Counter register shows a sequence of values: 0035, 0036, 0000, and 0001. A counter overflow occurs when the register transitions from 0036 to 0000, which coincides with the falling edge of the Timerclock. This event triggers an Update event (UEV) and sets the Update interrupt flag (UIF). Vertical dashed lines indicate the timing of these events relative to the clock signals.

MS31080V2

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timerclock = CK_CNT, Counter register (0035 to 0001), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 528. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 528 showing CK_PSC, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by N. It shows the following signals over time:

MS31081V2

Timing diagram for Figure 528 showing CK_PSC, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 529. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded)

Timing diagram for Figure 529 showing CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

This timing diagram illustrates the operation of a counter when ARPE = 0 and the TIMx_ARR is not preloaded. It shows the following signals over time:

Write a new value in TIMx_ARR

MS31082V2

Timing diagram for Figure 529 showing CK_PSC, CEN, Timerclock = CK_CNT, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Figure 530. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Timing diagram for a counter with ARPE=1. It shows the relationship between CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register. The counter register shows values F0 to F7, with an overflow at F7. The auto-reload preload register is updated from F5 to 36, and the shadow register is updated from F5 to 36. A write to TIMx_ARR is shown at the bottom.

The diagram illustrates the timing of a counter when ARPE=1 (TIMx_ARR preloaded). The signals shown are:

MS31083V2

Timing diagram for a counter with ARPE=1. It shows the relationship between CK_PSC, CEN, Timerclock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register. The counter register shows values F0 to F7, with an overflow at F7. The auto-reload preload register is updated from F5 to 36, and the shadow register is updated from F5 to 36. A write to TIMx_ARR is shown at the bottom.

44.3.3 UIF bit remapping

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the Update Interrupt Flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This allows to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (Update Interrupt).

There is no latency between the assertions of the UIF and UIFCPY flags.

44.3.4 Clock source

The counter clock is provided by the Internal clock (CK_INT) source.

The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 531 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 531. Control circuit in normal mode, internal clock divided by 1

Timing diagram for the control circuit in normal mode. It shows the relationship between the Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and the Counter register. The Counter register is shown as a sequence of bits from 31 to 07. The Counter clock is derived from the Internal clock. The CEN=CNT_EN signal enables the counter. The UG signal is a pulse that triggers a counter update. The CNT_INIT signal is a pulse that initializes the counter. The Counter register is updated on the rising edge of the Counter clock.

MS31085V2

Timing diagram for the control circuit in normal mode. It shows the relationship between the Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock = CK_CNT = CK_PSC, and the Counter register. The Counter register is shown as a sequence of bits from 31 to 07. The Counter clock is derived from the Internal clock. The CEN=CNT_EN signal enables the counter. The UG signal is a pulse that triggers a counter update. The CNT_INIT signal is a pulse that initializes the counter. The Counter register is updated on the rising edge of the Counter clock.

44.3.5 Debug mode

When the system enters debug mode (processor core halted), the TIMx counter either continues to work normally or stops, depending on TIMx bit in DBGMCU module. For more details, refer to Section 66.10.9: Microprocessor debug unit (DBGMCU).

44.4 TIM6/TIM7 registers

Refer to Section 1.2 on page 121 for a list of abbreviations used in register descriptions.

The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).

44.4.1 TIMx control register 1 (TIMx_CR1)(x = 6 to 7)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.UIFRE
MAP
Res.Res.Res.ARPERes.Res.Res.OPMURSUDISCEN
rwrwrwrwrwrw

Bits 15:12 Reserved, must be kept at reset value.

Bit 11 UIFREMAP: UIF status bit remapping

0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.

1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.

Bits 10:8 Reserved, must be kept at reset value.

Bits 6:4 Reserved, must be kept at reset value.

44.4.2 TIMx control register 2 (TIMx_CR2)(x = 6 to 7)

Address offset: 0x04

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.MMS[2:0]Res.Res.Res.Res.
rwrwrw

Bits 15:7 Reserved, must be kept at reset value.

Bits 6:4 MMS[2:0]: Master mode selection

These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:

000: Reset - the UG bit from the TIMx_EGR register is used as a trigger output (TRGO). If reset is generated by the trigger input (slave mode controller configured in reset mode) then the signal on TRGO is delayed compared to the actual reset.

001: Enable - the Counter enable signal, CNT_EN, is used as a trigger output (TRGO). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated by a logic OR between CEN control bit and the trigger input when configured in gated mode.

When the Counter Enable signal is controlled by the trigger input, there is a delay on TRGO, except if the master/slave mode is selected (see the MSM bit description in the TIMx_SMCR register).

010: Update - The update event is selected as a trigger output (TRGO). For instance a master timer can then be used as a prescaler for a slave timer.

Note: The clock of the slave timer or ADC must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Bits 3:0 Reserved, must be kept at reset value.

44.4.3 TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 6 to 7)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.UDERes.Res.Res.Res.Res.Res.Res.UIE
rwrw

Bits 15:9 Reserved, must be kept at reset value.

Bit 8 UDE: Update DMA request enable

0: Update DMA request disabled.

1: Update DMA request enabled.

Bits 7:1 Reserved, must be kept at reset value.

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled.

1: Update interrupt enabled.

44.4.4 TIMx status register (TIMx_SR)(x = 6 to 7)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UIF
rc_w0

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

44.4.5 TIMx event generation register (TIMx_EGR)(x = 6 to 7)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UG
w

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action.

1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).

44.4.6 TIMx counter (TIMx_CNT)(x = 6 to 7)

Address offset: 0x24

Reset value: 0x0000 0000

31302928272625242322212019181716
UIF
CPY
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
r
1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 31 UIFCPY: UIF Copy

This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.

Bits 30:16 Reserved, must be kept at reset value.

Bits 15:0 CNT[15:0]: Counter value

44.4.7 TIMx prescaler (TIMx_PSC)(x = 6 to 7)

Address offset: 0x28

Reset value: 0x0000

RM0436 44.4.7column_2Bit 31 Bits 15:0UIFCPY CNT[15:0]: UIF Copy: Counter valuecolumn_7column_8column_9column_10column_11column_12column_13column_14column_15column_16
151413121110987 PSC[15:0]6543210
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
Bits 15:0PSC[15:0]: Prescaler value
151413121110987 ARR[15:0]6543210
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
Bits 15:0ARR[15:0]: Prescaler value
Refer to behavior.Section 44.3.1: Time-base unit on page 2345for more details about ARR update and

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency CK_CNT is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded into the active prescaler register at each update event.
(including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

44.4.8 TIMx auto-reload register (TIMx_ARR)(x = 6 to 7)

Address offset: 0x2C

Reset value: 0xFFFF

Bits 15:0 ARR[15:0]: Prescaler value

ARR is the value to be loaded into the actual auto-reload register.

Refer to Section 44.3.1: Time-base unit on page 2345 for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

44.4.9 TIMx register map

TIMx registers are mapped as 16-bit addressable registers as described in the table below:

Table 312. TIMx register map and reset values

OffsetRegister name313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UIFREMARes.Res.Res.ARPERes.Res.Res.OPMURSUDISCEN
Reset value000000
0x04TIMx_CR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.MMS [2:0]Res.Res.Res.Res.Res.Res.
Reset value000
0x08Reserved
0x0CTIMx_DIERRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UDERes.Res.Res.Res.Res.Res.Res.UIE
Reset value00
0x10TIMx_SRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UIF
Reset value0
0x14TIMx_EGRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UG
Reset value0
0x18-0x20Reserved
0x24TIMx_CNTUIFCPY or Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CNT[15:0]
Reset value00000000000
0x28TIMx_PSCRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.PSC[15:0]
Reset value00000000000
0x2CTIMx_ARRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ARR[15:0]
Reset value11111111111

Refer to Section 2.5 on page 159 for the register boundary addresses.