26. Peripheral interconnects ..... 1492
| 26.1 | Introduction ..... | 1492 |
| 26.2 | Connection overview ..... | 1492 |
| 26.2.1 | Asynchronous connections (A) ..... | 1492 |
| 26.2.2 | Synchronous connections (S) ..... | 1492 |
| 26.2.3 | Break/fault connection for TIM outputs (B) ..... | 1492 |
| 26.2.4 | Peripherals interconnect matrix ..... | 1493 |
| 27 | High-performance direct memory access controller (HPDMA) ... | 1517 |
| 27.1 | HPDMA introduction ..... | 1517 |
| 27.2 | HPDMA main features ..... | 1517 |
| 27.3 | HPDMA implementation ..... | 1518 |
| 27.3.1 | HPDMA channels ..... | 1518 |
| 27.3.2 | HPDMA allowed AXI maximum burst length ..... | 1519 |
| 27.3.3 | HPDMA autonomous mode in low-power modes ..... | 1519 |
| 27.3.4 | HPDMA requests ..... | 1519 |
| 27.3.5 | HPDMA block requests ..... | 1525 |
| 27.3.6 | HPDMA channels with peripheral early termination ..... | 1525 |
| 27.3.7 | HPDMA triggers ..... | 1526 |
| 27.4 | HPDMA functional description ..... | 1529 |
| 27.4.1 | HPDMA block diagram ..... | 1529 |
| 27.4.2 | HPDMA channel state and direct programming without any linked-list ..... | 1529 |
| 27.4.3 | HPDMA channel suspend and resume ..... | 1530 |
| 27.4.4 | HPDMA channel abort and restart ..... | 1531 |
| 27.4.5 | HPDMA linked-list data structure ..... | 1532 |
| 27.4.6 | Linked-list item transfer execution ..... | 1535 |
| 27.4.7 | HPDMA channel state and linked-list programming in run-to-completion mode ..... | 1536 |
| 27.4.8 | HPDMA channel state and linked-list programming in link step mode ..... | 1540 |
| 27.4.9 | HPDMA channel state and linked-list programming ..... | 1547 |
| 27.4.10 | HPDMA FIFO-based transfers ..... | 1549 |
| 27.4.11 | HPDMA transfer request and arbitration ..... | 1565 |
| 27.4.12 | HPDMA triggered transfer ..... | 1569 |
| 27.4.13 | HPDMA circular buffering with linked-list programming ..... | 1570 |
| 27.4.14 | HPDMA transfer in peripheral flow-control mode ..... | 1572 |
| 27.4.15 | HPDMA secure/nonsecure channel ..... | 1573 |
| 27.4.16 | HPDMA privileged/unprivileged channel | 1574 |
| 27.4.17 | HPDMA error management | 1574 |
| 27.4.18 | HPDMA autonomous mode | 1576 |
| 27.5 | HPDMA in debug mode | 1577 |
| 27.6 | HPDMA in low-power modes | 1578 |
| 27.7 | HPDMA interrupts | 1578 |
| 27.8 | HPDMA registers | 1580 |
| 27.8.1 | HPDMA secure configuration register (HPDMA_SECCFGR) | 1580 |
| 27.8.2 | HPDMA privileged configuration register (HPDMA_PRIVCFGR) | 1581 |
| 27.8.3 | HPDMA configuration lock register (HPDMA_RCFGLOCKR) | 1581 |
| 27.8.4 | HPDMA nonsecure masked interrupt status register (HPDMA_MISR) | 1582 |
| 27.8.5 | HPDMA secure masked interrupt status register (HPDMA_SMISR) | 1583 |
| 27.8.6 | HPDMA channel x linked-list base address register (HPDMA_CxLBAR) | 1584 |
| 27.8.7 | HPDMA channel x CID register (HPDMA_CxCIDCFGR) | 1584 |
| 27.8.8 | HPDMA channel x semaphore control register (HPDMA_CxSEMCR) | 1586 |
| 27.8.9 | HPDMA channel x flag clear register (HPDMA_CxFCR) | 1587 |
| 27.8.10 | HPDMA channel x status register (HPDMA_CxSR) | 1588 |
| 27.8.11 | HPDMA channel x control register (HPDMA_CxCR) | 1589 |
| 27.8.12 | HPDMA channel x transfer register 1 (HPDMA_CxTR1) | 1592 |
| 27.8.13 | HPDMA channel x transfer register 2 (HPDMA_CxTR2) | 1596 |
| 27.8.14 | HPDMA channel x block register 1 (HPDMA_CxBR1) | 1600 |
| 27.8.15 | HPDMA channel x alternate block register 1 (HPDMA_CxBR1) | 1601 |
| 27.8.16 | HPDMA channel x source address register (HPDMA_CxSAR) | 1604 |
| 27.8.17 | HPDMA channel x destination address register (HPDMA_CxDAR) | 1606 |
| 27.8.18 | HPDMA channel x transfer register 3 (HPDMA_CxTR3) | 1608 |
| 27.8.19 | HPDMA channel x block register 2 (HPDMA_CxBR2) | 1610 |
| 27.8.20 | HPDMA channel x linked-list address register (HPDMA_CxLLR) | 1611 |
| 27.8.21 | HPDMA channel x alternate linked-list address register (HPDMA_CxLLR) | 1613 |
| 27.8.22 | HPDMA hardware configuration 13 register (HPDMA_HWCFGR13) | 1614 |
| 27.8.23 | HPDMA hardware configuration 12 register (HPDMA_HWCFGR12) | 1616 |
| 27.8.24 | HPDMA hardware configuration 11 register (HPDMA_HWCFGR11) | 1617 |
| 27.8.25 | HPDMA hardware configuration 10 register (HPDMA_HWCFGR10) | 1618 |
| 27.8.26 | HPDMA hardware configuration 9 register (HPDMA_HWCFGR9) | 1619 |
| 27.8.27 | HPDMA hardware configuration 8 register (HPDMA_HWCFGR8) | 1620 |
| 27.8.28 | HPDMA hardware configuration 7 register (HPDMA_HWCFGR7) .. | 1621 |
| 27.8.29 | HPDMA hardware configuration 6 register (HPDMA_HWCFGR6) .. | 1622 |
| 27.8.30 | HPDMA hardware configuration 5 register (HPDMA_HWCFGR5) .. | 1624 |
| 27.8.31 | HPDMA hardware configuration 4 register (HPDMA_HWCFGR4) .. | 1625 |
| 27.8.32 | HPDMA hardware configuration 3 register (HPDMA_HWCFGR3) .. | 1626 |
| 27.8.33 | HPDMA hardware configuration 2 register (HPDMA_HWCFGR2) .. | 1627 |
| 27.8.34 | HPDMA hardware configuration 1 register (HPDMA_HWCFGR1) .. | 1627 |
| 27.8.35 | HPDMA version register (HPDMA_VERR) ..... | 1629 |
| 27.8.36 | HPDMA identification register (HPDMA_IPIDR) ..... | 1629 |
| 27.8.37 | HPDMA size identification register (HPDMA_SIDR) ..... | 1629 |
| 27.8.38 | HPDMA register map ..... | 1630 |
| 28 | Low-power direct memory access controller (LPDMA) ..... | 1634 |
| 28.1 | LPDMA introduction ..... | 1634 |
| 28.2 | LPDMA main features ..... | 1634 |
| 28.3 | LPDMA implementation ..... | 1635 |
| 28.3.1 | LPDMA channels ..... | 1635 |
| 28.3.2 | LPDMA autonomous mode in low-power modes ..... | 1636 |
| 28.3.3 | LPDMA requests ..... | 1636 |
| 28.3.4 | LPDMA block requests ..... | 1637 |
| 28.3.5 | LPDMA channels with peripheral early termination ..... | 1637 |
| 28.3.6 | LPDMA triggers ..... | 1637 |
| 28.4 | LPDMA functional description ..... | 1639 |
| 28.4.1 | LPDMA block diagram ..... | 1639 |
| 28.4.2 | LPDMA channel state and direct programming without any linked-list ..... | 1639 |
| 28.4.3 | LPDMA channel suspend and resume ..... | 1640 |
| 28.4.4 | LPDMA channel abort and restart ..... | 1641 |
| 28.4.5 | LPDMA linked-list data structure ..... | 1642 |
| 28.4.6 | Linked-list item transfer execution ..... | 1644 |
| 28.4.7 | LPDMA channel state and linked-list programming in run-to-completion mode ..... | 1644 |
| 28.4.8 | LPDMA channel state and linked-list programming in link step mode | 1649 |
| 28.4.9 | LPDMA channel state and linked-list programming ..... | 1655 |
| 28.4.10 | LPDMA direct transfers ..... | 1657 |
| 28.4.11 | LPDMA transfer request and arbitration ..... | 1659 |
| 28.4.12 | LPDMA triggered transfer ..... | 1663 |
| 28.4.13 | LPDMA circular buffering with linked-list programming | 1664 |
| 28.4.14 | LPDMA transfer in peripheral flow-control mode | 1666 |
| 28.4.15 | LPDMA secure/nonsecure channel | 1667 |
| 28.4.16 | LPDMA privileged/unprivileged channel | 1667 |
| 28.4.17 | LPDMA error management | 1668 |
| 28.4.18 | LPDMA autonomous mode | 1669 |
| 28.5 | LPDMA in debug mode | 1671 |
| 28.6 | LPDMA in low-power modes | 1671 |
| 28.7 | LPDMA interrupts | 1671 |
| 28.8 | LPDMA registers | 1673 |
| 28.8.1 | LPDMA secure configuration register (LPDMA_SECCFGR) | 1673 |
| 28.8.2 | LPDMA privileged configuration register (LPDMA_PRIVCFGR) | 1674 |
| 28.8.3 | LPDMA configuration lock register (LPDMA_RCFGLOCKR) | 1675 |
| 28.8.4 | LPDMA nonsecure masked interrupt status register (LPDMA_MISR) | 1675 |
| 28.8.5 | LPDMA secure masked interrupt status register (LPDMA_SMISR) | 1676 |
| 28.8.6 | LPDMA channel x linked-list base address register (LPDMA_CxLBAR) | 1677 |
| 28.8.7 | LPDMA channel x CID register (LPDMA_CxCIDCFGR) | 1678 |
| 28.8.8 | LPDMA channel x semaphore control register (LPDMA_CxSEMCR) | 1679 |
| 28.8.9 | LPDMA channel x flag clear register (LPDMA_CxFCR) | 1680 |
| 28.8.10 | LPDMA channel x status register (LPDMA_CxSR) | 1681 |
| 28.8.11 | LPDMA channel x control register (LPDMA_CxCR) | 1683 |
| 28.8.12 | LPDMA channel x transfer register 1 (LPDMA_CxTR1) | 1685 |
| 28.8.13 | LPDMA channel x transfer register 2 (LPDMA_CxTR2) | 1687 |
| 28.8.14 | LPDMA channel x block register 1 (LPDMA_CxBR1) | 1690 |
| 28.8.15 | LPDMA channel x source address register (LPDMA_CxSAR) | 1692 |
| 28.8.16 | LPDMA channel x destination address register (LPDMA_CxDAR) | 1693 |
| 28.8.17 | LPDMA channel x linked-list address register (LPDMA_CxLLR) | 1694 |
| 28.8.18 | LPDMA hardware configuration 13 register (LPDMA_HWCFGR13) | 1695 |
| 28.8.19 | LPDMA hardware configuration 12 register (LPDMA_HWCFGR12) | 1696 |
| 28.8.20 | LPDMA hardware configuration 11 register (LPDMA_HWCFGR11) | 1697 |
| 28.8.21 | LPDMA hardware configuration 10 register (LPDMA_HWCFGR10) | 1698 |
| 28.8.22 | LPDMA hardware configuration 9 register (LPDMA_HWCFGR9) | 1699 |
| 28.8.23 | LPDMA hardware configuration 8 register (LPDMA_HWCFGR8) | 1701 |
| 28.8.24 | LPDMA hardware configuration 7 register (LPDMA_HWCFGR7) | 1702 |
| 28.8.25 | LPDMA hardware configuration 6 register (LPDMA_HWCFGR6) | 1703 |
| 28.8.26 | LPDMA hardware configuration 5 register (LPDMA_HWCFGR5) . . . | 1704 |
| 28.8.27 | LPDMA hardware configuration 4 register (LPDMA_HWCFGR4) . . . | 1705 |
| 28.8.28 | LPDMA hardware configuration 3 register (LPDMA_HWCFGR3) . . . | 1706 |
| 28.8.29 | LPDMA hardware configuration 2 register (LPDMA_HWCFGR2) . . . | 1707 |
| 28.8.30 | LPDMA hardware configuration 1 register (LPDMA_HWCFGR1) . . . | 1708 |
| 28.8.31 | LPDMA version register (LPDMA_VERR) . . . . . | 1709 |
| 28.8.32 | LPDMA identification register (LPDMA_IPIDR) . . . . . | 1709 |
| 28.8.33 | LPDMA size identification register (LPDMA_SIDR) . . . . . | 1709 |
| 28.8.34 | LPDMA register map . . . . . | 1710 |
| 29 | Graphic processing unit (GPU) . . . . . | 1713 |
| 29.1 | Introduction . . . . . | 1713 |
| 29.2 | GPU main features . . . . . | 1713 |
| 29.2.1 | Graphic Main Features . . . . . | 1713 |
| 29.2.2 | Computing main features . . . . . | 1714 |
| 29.2.3 | Neural networkmain features . . . . . | 1714 |
| 29.2.4 | Simultaneous processing of Gfx versus Neural versus computing tasks . . . . . | 1714 |
| 29.3 | GPU implementation . . . . . | 1714 |
| 29.4 | GPU functional description . . . . . | 1714 |
| 29.4.1 | GPU block diagram . . . . . | 1714 |
| 29.4.2 | GPU pins and internal signals . . . . . | 1715 |
| 29.4.3 | GPU reset and clocks . . . . . | 1715 |
| 29.4.4 | GPU security . . . . . | 1716 |
| 29.4.5 | GPU power-on sequence . . . . . | 1716 |
| 29.5 | GPU low power modes . . . . . | 1717 |
| 29.6 | GPU interrupts . . . . . | 1717 |
| 29.7 | GPU registers . . . . . | 1717 |
| 29.7.1 | GPU AQ Hi clock control register (GPU_AQHICLOCKCONTROL) . . | 1717 |
| 29.7.2 | GPU AQ Hi Idle Register (GPU_AQHIIIDLE) . . . . . | 1718 |
| 29.7.3 | GPU AQ AXI status register (GPU_AQAXISTATUS) . . . . . | 1719 |
| 29.7.4 | GPU AQ interrupt acknowledge register (GPU_AQINTRACKNOWLEDGE) . . . . . | 1719 |
| 29.7.5 | GPU AQ interrupt enable register (GPU_AQINTRENBL) . . . . . | 1720 |
| 29.7.6 | GPU GC chip revision register (GPU_GCCHIPREV) . . . . . | 1720 |
| 29.7.7 | GPU GC chip date register (GPU_GCCHIPDATE) . . . . . | 1720 |
| 29.7.8 | GPU GC total cycles register (GPU_GCTOTALCYCLES) . . . . . | 1721 |
| 29.7.9 | GPU GC registration Hi chip patch revision register (GPU_GCREGHICHIPPATCHREV) ..... | 1721 |
| 29.7.10 | GPU GC product identification register (GPU_GCPRODUCTID) ... | 1721 |
| 29.7.11 | GPU GC ECO identification register (GPU_GCECOID) ..... | 1722 |
| 29.7.12 | GPU GC module power control register (GPU_GCMODULEPOWERCONTROLS) ..... | 1722 |
| 29.7.13 | GPU GC MMU AHB control register (GPU_GCREGMMUAHBCONTROL) ..... | 1723 |
| 29.7.14 | GPU GC MMU AHB table array base address low register (GPU_GCREGMMUAHBTABLEARRAYBASEADDRESSLOW) .... | 1723 |
| 29.7.15 | GPU GC MMU AHB table array base address high register (GPU_GCREGMMUAHBTABLEARRAYBASEADDRESSHIGH) ... | 1724 |
| 29.7.16 | GPU GC MMU AHB table array size register (GPU_GCREGMMUAHBTABLEARRAYSIZE) ..... | 1724 |
| 29.7.17 | GPU GC MMU AHB safe non-secure address register (GPU_GCREGMMUAHBSAFENONSECUREADDRESS) ..... | 1725 |
| 29.7.18 | GPU GC MMU AHB safe secure address register (GPU_GCREGMMUAHBSAFESECUREADDRESS) ..... | 1725 |
| 29.7.19 | GPU GC command buffer AHB control register (GPU_GCREGCMDBUFFERAHBCTRL) ..... | 1725 |
| 29.7.20 | GPU GC Hi AHB control register (GPU_GCREGHIAHBCONTROL) ..... | 1726 |
| 29.7.21 | GPU GC AXI AHB configuration register (GPU_GCREGAXIAHBCONFIG) ..... | 1726 |
| 29.7.22 | GPU AQ memory debug register (GPU_AQMEMORYDEBUG) .... | 1727 |
| 29.7.23 | GPU AQ timing control register (GPU_AQREGISTERTIMINGCONTROL) ..... | 1727 |
| 29.7.24 | GPU AQ command buffer address register (GPU_AQCMDBUFFERADDR) ..... | 1728 |
| 29.7.25 | GPU AQ FE debug current command address register (GPU_AQFEDEBUGCURCMDADR) ..... | 1728 |
| 29.7.26 | GPU register map ..... | 1728 |
| 30 | Neural processing unit (NPU) ..... | 1733 |
| 30.1 | Introduction ..... | 1733 |
| 30.2 | NPU main features ..... | 1733 |
| 30.3 | NPU implementation ..... | 1733 |
| 30.4 | NPU functional description ..... | 1734 |
| 30.5 | NPU low-power modes ..... | 1734 |
| 30.6 | NPU interrupts ..... | 1734 |
| 30.7 | NPU registers ..... | 1734 |
| 31 | Interrupt list ..... | 1735 |
| 31.1 | NVIC interrupts ..... | 1735 |
| 31.2 | GIC interrupts ..... | 1746 |
| 32 | Nested vectored interrupt controllers (NVIC) ..... | 1759 |
| 32.1 | NVIC features ..... | 1759 |
| 32.2 | SysTick calibration value register ..... | 1759 |
| 32.3 | Interrupt and exception vectors ..... | 1760 |
| 33 | Global interrupt controller (GIC) ..... | 1761 |
| 33.1 | GIC introduction ..... | 1761 |
| 33.2 | GIC main features ..... | 1761 |
| 33.3 | GIC functional description ..... | 1761 |
| 33.4 | GIC interrupt sources ..... | 1762 |
| 33.4.1 | Software generated interrupts (SGI) ..... | 1762 |
| 33.4.2 | Private peripheral interrupts (PPI) ..... | 1763 |
| 33.4.3 | Shared peripheral interrupts (SPI) ..... | 1763 |
| 33.4.4 | Interrupt priority formats ..... | 1763 |
| 33.5 | GIC distributor (GICD) ..... | 1763 |
| 33.5.1 | GICD control register (GICD_CTLR) ..... | 1764 |
| 33.5.2 | GICD control non-secure access register (GICD_CTLRNS) ..... | 1764 |
| 33.5.3 | GICD interrupt controller type register (GICD_TYPER) ..... | 1765 |
| 33.5.4 | GICD implementer identification register (GICD_IIDR) ..... | 1765 |
| 33.5.5 | GICD interrupt group register x (GICD_IGROUPRx) ..... | 1766 |
| 33.5.6 | GICD interrupt set-enable register (GICD_ISENABLER0) ..... | 1766 |
| 33.5.7 | GICD interrupt set-enable register x (GICD_ISENABLERx) ..... | 1767 |
| 33.5.8 | GICD interrupt clear-enable register (GICD_ICENABLER0) ..... | 1767 |
| 33.5.9 | GICD interrupt clear-enable register x (GICD_ICENABLERx) ..... | 1767 |
| 33.5.10 | GICD interrupt set-pending register x (GICD_ISPENDRx) ..... | 1768 |
| 33.5.11 | GICD interrupt clear-pending register x (GICD_ICPENDRx) ..... | 1768 |
| 33.5.12 | GICD interrupt set-active register x (GICD_ISACTIVERx) ..... | 1768 |
| 33.5.13 | GICD interrupt clear-active register x (GICD_ICACTIVERx) ..... | 1769 |
| 33.5.14 | GICD interrupt priority register x (GICD_IPRIORITYRx) ..... | 1769 |
| 33.5.15 | GICD interrupt processor target register x (GICD_ITARGETSRx) .. | 1770 |
| 33.5.16 | GICD interrupt processor target register x (GICD_ITARGETSRx) . . . | 1770 |
| 33.5.17 | GICD interrupt configuration register (GICD_ICFGR0) . . . . . | 1771 |
| 33.5.18 | GICD interrupt configuration register (GICD_ICFGR1) . . . . . | 1771 |
| 33.5.19 | GICD interrupt configuration register x (GICD_ICFGRx) . . . . . | 1771 |
| 33.5.20 | GICD private peripheral interrupt status register (GICD_PPISR) . . . | 1772 |
| 33.5.21 | GICD shared peripheral interrupt register x (GICD_SPISRx) . . . . . | 1772 |
| 33.5.22 | GICD software generated interrupt register (GICD_SGIR) . . . . . | 1773 |
| 33.5.23 | GICD SGI clear-pending register x (GICD_CPENDSGIRx) . . . . . | 1774 |
| 33.5.24 | GICD SGI set-pending register x (GICD_SPENDSGIRx) . . . . . | 1775 |
| 33.5.25 | GICD peripheral ID4 register (GICD_PIDR4) . . . . . | 1776 |
| 33.5.26 | GICD peripheral ID5 to ID7 register x (GICD_PIDRx) . . . . . | 1776 |
| 33.5.27 | GICD peripheral ID0 register (GICD_PIDR0) . . . . . | 1776 |
| 33.5.28 | GICD peripheral ID1 register (GICD_PIDR1) . . . . . | 1777 |
| 33.5.29 | GICD peripheral ID2 register (GICD_PIDR2) . . . . . | 1777 |
| 33.5.30 | GICD peripheral ID3 register (GICD_PIDR3) . . . . . | 1777 |
| 33.5.31 | GICD component ID0 register (GICD_CIDR0) . . . . . | 1778 |
| 33.5.32 | GICD component ID1 register (GICD_CIDR1) . . . . . | 1778 |
| 33.5.33 | GICD component ID2 register (GICD_CIDR2) . . . . . | 1778 |
| 33.5.34 | GICD component ID3 register (GICD_CIDR3) . . . . . | 1779 |
| 33.5.35 | GICD register map . . . . . | 1779 |
| 33.6 | GIC CPU interface (GICC) . . . . . | 1782 |
| 33.6.1 | GICC control register (GICC_CTLR) . . . . . | 1782 |
| 33.6.2 | GICC control non-secure access register (GICC_CTLRNS) . . . . . | 1783 |
| 33.6.3 | GICC input priority mask register (GICC_PMR) . . . . . | 1784 |
| 33.6.4 | GICC binary point register (GICC_BPR) . . . . . | 1784 |
| 33.6.5 | GICC binary point non-secure access register (GICC_BPRNS) . . . . | 1785 |
| 33.6.6 | GICC interrupt acknowledge register (GICC_IAR) . . . . . | 1785 |
| 33.6.7 | GICC end of interrupt register (GICC_EOIR) . . . . . | 1786 |
| 33.6.8 | GICC running priority register (GICC_RPR) . . . . . | 1786 |
| 33.6.9 | GICC highest priority pending interrupt register (GICC_HPPIR) . . . . | 1786 |
| 33.6.10 | GICC aliased binary point register (GICC_ABPR) . . . . . | 1787 |
| 33.6.11 | GICC aliased interrupt acknowledge register (GICC_AIAR) . . . . . | 1787 |
| 33.6.12 | GICC aliased end of interrupt register (GICC_AEOIR) . . . . . | 1788 |
| 33.6.13 | GICC aliased highest priority pending interrupt register (GICC_AHPPIR) . . . . . | 1788 |
| 33.6.14 | GICC active priority register (GICC_APR0) . . . . . | 1789 |
| 33.6.15 | GICC non-secure active priority register (GICC_NSAPR0) . . . . . | 1789 |
| 33.6.16 | GICC interface identification register (GICC_IIDR) . . . . . | 1789 |
| 33.6.17 | GICC deactivate interrupt register (GICC_DIR) . . . . . | 1790 |
| 33.6.18 | GICC register map . . . . . | 1790 |
| 33.7 | GIC virtual interface control, common (GICH) . . . . . | 1792 |
| 33.7.1 | GICH hypervisor control register (GICH_HCR) . . . . . | 1792 |
| 33.7.2 | GICH VGIC type register (GICH_VTR) . . . . . | 1793 |
| 33.7.3 | GICH virtual machine control register (GICH_VMCR) . . . . . | 1793 |
| 33.7.4 | GICH maintenance interrupt status register (GICH_MISR) . . . . . | 1794 |
| 33.7.5 | GICH end of interrupt status register (GICH_EISR0) . . . . . | 1795 |
| 33.7.6 | GICH empty list status register (GICH_ELSR0) . . . . . | 1795 |
| 33.7.7 | GICH active priority register (GICH_APR0) . . . . . | 1795 |
| 33.7.8 | GICH list register x (GICH_LRx) . . . . . | 1796 |
| 33.7.9 | GICH register map . . . . . | 1796 |
| 33.8 | GIC virtual CPU interface (GICV) . . . . . | 1797 |
| 33.8.1 | GICV virtual machine control register (GICV_CTLR) . . . . . | 1798 |
| 33.8.2 | GICV VM priority mask register (GICV_PMR) . . . . . | 1798 |
| 33.8.3 | GICV VM binary point register (GICV_BPR) . . . . . | 1799 |
| 33.8.4 | GICV VM interrupt acknowledge register (GICV_IAR) . . . . . | 1799 |
| 33.8.5 | GICV VM end of interrupt register (GICV_EOIR) . . . . . | 1800 |
| 33.8.6 | GICV VM running priority register (GICV_RPR) . . . . . | 1800 |
| 33.8.7 | GICV VM highest priority pending interrupt register (GICV_HPPIR) . . . . . | 1801 |
| 33.8.8 | GICV VM aliased binary point register (GICV_ABPR) . . . . . | 1801 |
| 33.8.9 | GICV VM aliased interrupt register (GICV_AIAR) . . . . . | 1802 |
| 33.8.10 | GICV VM aliased end of interrupt register (GICV_AEOIR) . . . . . | 1802 |
| 33.8.11 | GICV VM aliased highest priority pending interrupt register (GICV_AHPPIR) . . . . . | 1803 |
| 33.8.12 | GICV VM active priority register (GICV_APR0) . . . . . | 1803 |
| 33.8.13 | GICV VM CPU interface identification register (GICV_IIDR) . . . . . | 1804 |
| 33.8.14 | GICV VM deactivate interrupt register (GICV_DIR) . . . . . | 1804 |
| 33.8.15 | GICV register map . . . . . | 1804 |
| 34 | Extended interrupts and event controller (EXTI) . . . . . | 1807 |
| 34.1 | EXTI main features . . . . . | 1807 |
| 34.2 | EXTI implementation . . . . . | 1808 |
| 34.3 | EXTI block diagram . . . . . | 1808 |
| 34.3.1 | EXTI connections between peripherals and CPU . . . . . | 1810 |
| 34.3.2 | EXTI1 wake-up interrupt list . . . . . | 1811 |
| 34.3.3 | EXTI2 wake-up interrupt list . . . . . | 1814 |
| 34.4 | EXTI functional description . . . . . | 1817 |
| 34.4.1 | EXTI configurable event input wake-up . . . . . | 1817 |
| 34.4.2 | EXTI direct event input wake-up . . . . . | 1818 |
| 34.4.3 | EXTI multiplexer selection . . . . . | 1819 |
| 34.5 | EXTI functional behavior . . . . . | 1819 |
| 34.6 | EXTI event protection . . . . . | 1820 |
| 34.6.1 | EXTI register security protection . . . . . | 1821 |
| 34.6.2 | EXTI register privilege protection . . . . . | 1821 |
| 34.6.3 | EXTI register CID protection . . . . . | 1821 |
| 34.7 | EXTIx registers . . . . . | 1822 |
| 34.7.1 | EXTI1 rising trigger selection register (EXTI1_RTSR1) . . . . . | 1823 |
| 34.7.2 | EXTI1 falling trigger selection register (EXTI1_FTSR1) . . . . . | 1824 |
| 34.7.3 | EXTI1 software interrupt event register (EXTI1_SWIER1) . . . . . | 1824 |
| 34.7.4 | EXTI1 rising edge pending register (EXTI1_RPR1) . . . . . | 1825 |
| 34.7.5 | EXTI1 falling edge pending register (EXTI1_FPR1) . . . . . | 1826 |
| 34.7.6 | EXTI1 security configuration register (EXTI1_SECCFGR1) . . . . . | 1826 |
| 34.7.7 | EXTI1 privilege configuration register (EXTI1_PRIVCFGR1) . . . . . | 1827 |
| 34.7.8 | EXTI1 rising trigger selection register (EXTI1_RTSR2) . . . . . | 1828 |
| 34.7.9 | EXTI1 falling trigger selection register (EXTI1_FTSR2) . . . . . | 1828 |
| 34.7.10 | EXTI1 software interrupt event register (EXTI1_SWIER2) . . . . . | 1829 |
| 34.7.11 | EXTI1 rising edge pending register (EXTI1_RPR2) . . . . . | 1830 |
| 34.7.12 | EXTI1 falling edge pending register (EXTI1_FPR2) . . . . . | 1831 |
| 34.7.13 | EXTI1 security enable register (EXTI1_SECCFGR2) . . . . . | 1832 |
| 34.7.14 | EXTI1 privilege enable register (EXTI1_PRIVCFGR2) . . . . . | 1833 |
| 34.7.15 | EXTI1 rising trigger selection register (EXTI1_RTSR3) . . . . . | 1834 |
| 34.7.16 | EXTI1 falling trigger selection register (EXTI1_FTSR3) . . . . . | 1835 |
| 34.7.17 | EXTI1 software interrupt event register (EXTI1_SWIER3) . . . . . | 1836 |
| 34.7.18 | EXTI1 rising edge pending register (EXTI1_RPR3) . . . . . | 1837 |
| 34.7.19 | EXTI1 falling edge pending register (EXTI1_FPR3) . . . . . | 1838 |
| 34.7.20 | EXTI1 security enable register (EXTI1_SECCFGR3) . . . . . | 1839 |
| 34.7.21 | EXTI1 privilege enable register (EXTI1_PRIVCFGR3) . . . . . | 1840 |
| 34.7.22 | EXTI1 external interrupt selection register 1 (EXTI1_EXTICR1) . . . . | 1841 |
| 34.7.23 | EXTI1 external interrupt selection register 2 (EXTI1_EXTICR2) . . . . | 1844 |
| 34.7.24 | EXTI1 external interrupt selection register 3 (EXTI1_EXTICR3) . . . . | 1848 |
| 34.7.25 | EXTI1 external interrupt selection register 4 (EXTI1_EXTICR4) . . . . | 1852 |
| 34.7.26 | EXTI1 lock register (EXTI1_LOCKR) . . . . . | 1856 |
| 34.7.27 | EXTI1 CPUm wake-up with interrupt mask register (EXTI1_CmIMR1) (m = 1 to 2) | 1857 |
| 34.7.28 | EXTI1 CPU2 wake-up with event mask register (EXTI1_C2EMR1) | 1858 |
| 34.7.29 | EXTI1 CPUm wake-up with interrupt mask register (EXTI1_CmIMR2) (m = 1 to 2) | 1859 |
| 34.7.30 | EXTI1 CPUm wake-up with interrupt mask register (EXTI1_CmIMR3) (m = 1 to 2) | 1860 |
| 34.7.31 | EXTI1 CPU2 wake-up with event mask register (EXTI1_C2EMR3) | 1861 |
| 34.7.32 | EXTI1 event CID configuration register (EXTI1_EnCIDCFGR) | 1862 |
| 34.7.33 | EXTI1 processor m CID configuration register (EXTI1_CmCIDCFGR) | 1862 |
| 34.7.34 | EXTI1 hardware configuration registers 13 (EXTI1_HWCFGR13) | 1863 |
| 34.7.35 | EXTI1 hardware configuration registers 12 (EXTI1_HWCFGR12) | 1863 |
| 34.7.36 | EXTI1 hardware configuration registers 11 (EXTI1_HWCFGR11) | 1864 |
| 34.7.37 | EXTI1 hardware configuration registers 7 (EXTI1_HWCFGR7) | 1864 |
| 34.7.38 | EXTI1 hardware configuration registers 6 (EXTI1_HWCFGR6) | 1864 |
| 34.7.39 | EXTI1 hardware configuration registers 5 (EXTI1_HWCFGR5) | 1865 |
| 34.7.40 | EXTI1 hardware configuration registers 4 (EXTI1_HWCFGR4) | 1865 |
| 34.7.41 | EXTI1 hardware configuration registers 3 (EXTI1_HWCFGR3) | 1865 |
| 34.7.42 | EXTI1 hardware configuration registers 2 (EXTI1_HWCFGR2) | 1866 |
| 34.7.43 | EXTI1 hardware configuration register 1 (EXTI1_HWCFGR1) | 1866 |
| 34.7.44 | EXTI1 version register (EXTI1_VERR) | 1866 |
| 34.7.45 | EXTI1 identification register (EXTI1_IPIDR) | 1867 |
| 34.7.46 | EXTI1 size identification register (EXTI1_SIDR) | 1867 |
| 34.7.47 | EXTI2 rising trigger selection register (EXTI2_RTSR1) | 1867 |
| 34.7.48 | EXTI2 falling trigger selection register (EXTI2_FTSR1) | 1868 |
| 34.7.49 | EXTI2 software interrupt event register (EXTI2_SWIER1) | 1869 |
| 34.7.50 | EXTI2 rising edge pending register (EXTI2_RPR1) | 1870 |
| 34.7.51 | EXTI2 falling edge pending register (EXTI2_FPR1) | 1871 |
| 34.7.52 | EXTI2 security configuration register (EXTI2_SECCFGR1) | 1871 |
| 34.7.53 | EXTI2 privilege configuration register (EXTI2_PRIVCFGR1) | 1872 |
| 34.7.54 | EXTI2 rising trigger selection register (EXTI2_RTSR2) | 1873 |
| 34.7.55 | EXTI2 falling trigger selection register (EXTI2_FTSR2) | 1874 |
| 34.7.56 | EXTI2 software interrupt event register (EXTI2_SWIER2) | 1875 |
| 34.7.57 | EXTI2 rising edge pending register (EXTI2_RPR2) | 1875 |
| 34.7.58 | EXTI2 falling edge pending register (EXTI2_FPR2) | 1876 |
| 34.7.59 | EXTI2 security enable register (EXTI2_SECCFGR2) | 1877 |
| 34.7.60 | EXTI2 privilege enable register (EXTI2_PRIVCFGR2) | 1878 |
| 34.7.61 | EXTI2 rising trigger selection register (EXTI2_RTSR3) | 1879 |
| 34.7.62 | EXTI2 falling trigger selection register (EXTI2_FTSR3) | 1879 |
| 34.7.63 | EXTI2 software interrupt event register (EXTI2_SWIER3) | 1880 |
| 34.7.64 | EXTI2 rising edge pending register (EXTI2_RPR3) | 1881 |
| 34.7.65 | EXTI2 falling edge pending register (EXTI2_FPR3) | 1882 |
| 34.7.66 | EXTI2 security enable register (EXTI2_SECCFGR3) | 1882 |
| 34.7.67 | EXTI2 privilege enable register (EXTI2_PRIVCFGR3) | 1883 |
| 34.7.68 | EXTI2 external interrupt selection register 1 (EXTI2_EXTICR1) | 1884 |
| 34.7.69 | EXTI2 external interrupt selection register 2 (EXTI2_EXTICR2) | 1887 |
| 34.7.70 | EXTI2 external interrupt selection register 3 (EXTI2_EXTICR3) | 1891 |
| 34.7.71 | EXTI2 external interrupt selection register 4 (EXTI2_EXTICR4) | 1895 |
| 34.7.72 | EXTI2 lock register (EXTI2_LOCKR) | 1899 |
| 34.7.73 | EXTI2 CPUm wake-up with interrupt mask register (EXTI2_CmIMR1) (m = 1 to 3) | 1900 |
| 34.7.74 | EXTI2 CPUm wake-up with event mask register (EXTI2_CmEMR1) (m = 2 to 3) | 1901 |
| 34.7.75 | EXTI2 CPUm wake-up with interrupt mask register (EXTI2_CmIMR2) (m = 1 to 3) | 1902 |
| 34.7.76 | EXTI2 CPUm wake-up with event mask register (EXTI2_CmEMR2) (m = 2 to 3) | 1903 |
| 34.7.77 | EXTI2 CPUm wake-up with interrupt mask register (EXTI2_CmIMR3) (m = 1 to 3) | 1904 |
| 34.7.78 | EXTI2 event CID config register (EXTI2_EnCIDCFGR) | 1905 |
| 34.7.79 | EXTI2 processor m CID configuration register (EXTI2_CmCIDCFGR) | 1905 |
| 34.7.80 | EXTI2 hardware configuration registers 13 (EXTI2_HWCFGR13) | 1906 |
| 34.7.81 | EXTI2 hardware configuration registers 12 (EXTI2_HWCFGR12) | 1906 |
| 34.7.82 | EXTI2 hardware configuration registers 11 (EXTI2_HWCFGR11) | 1907 |
| 34.7.83 | EXTI2 hardware configuration registers 7 (EXTI2_HWCFGR7) | 1907 |
| 34.7.84 | EXTI2 hardware configuration registers 6 (EXTI2_HWCFGR6) | 1907 |
| 34.7.85 | EXTI2 hardware configuration registers 5 (EXTI2_HWCFGR5) | 1908 |
| 34.7.86 | EXTI2 hardware configuration registers 4 (EXTI2_HWCFGR4) | 1908 |
| 34.7.87 | EXTI2 hardware configuration registers 3 (EXTI2_HWCFGR3) | 1908 |
| 34.7.88 | EXTI2 hardware configuration registers 2 (EXTI2_HWCFGR2) | 1909 |
| 34.7.89 | EXTI2 hardware configuration register 1 (EXTI2_HWCFGR1) | 1909 |
| 34.7.90 | EXTI2 version register (EXTI2_VERR) | 1909 |
| 34.7.91 | EXTI2 identification register (EXTI2_IPIDR) | 1910 |
| 34.7.92 | EXTI2 size identification register (EXTI2_SIDR) | 1910 |
| 34.7.93 | EXTI1 register map | 1910 |
| 34.7.94 | EXTI2 register map | 1914 |
| 35 | Cyclic redundancy check calculation unit (CRC) | 1919 |
| 35.1 | Introduction | 1919 |
| 35.2 | CRC main features | 1919 |
| 35.3 | CRC functional description | 1920 |
| 35.3.1 | CRC block diagram | 1920 |
| 35.3.2 | CRC internal signals | 1920 |
| 35.3.3 | CRC operation | 1920 |
| 35.4 | CRC registers | 1922 |
| 35.4.1 | CRC data register (CRC_DR) | 1922 |
| 35.4.2 | CRC independent data register (CRC_IDR) | 1922 |
| 35.4.3 | CRC control register (CRC_CR) | 1923 |
| 35.4.4 | CRC initial value (CRC_INIT) | 1924 |
| 35.4.5 | CRC polynomial (CRC_POL) | 1924 |
| 35.4.6 | CRC hardware configuration register (CRC_HWCFGR) | 1924 |
| 35.4.7 | CRC version register (CRC_VERR) | 1925 |
| 35.4.8 | CRC identification register (CRC_IPIDR) | 1925 |
| 35.4.9 | CRC size identification register (CRC_SIDR) | 1926 |
| 35.4.10 | CRC register map | 1926 |
| 36 | Mass storage interfaces | 1928 |
| 36.1 | Overview | 1928 |
| 36.2 | FMC interface | 1928 |
| 36.2.1 | Main features of the FMC interface | 1928 |
| 36.2.2 | FMC interface block diagram | 1929 |
| 36.2.3 | FMC interface reset | 1929 |
| 36.2.4 | FMC interface interrupt | 1930 |
| 36.3 | Octo-SPI interface | 1930 |
| 36.3.1 | Main features of the Octo-SPI interface | 1930 |
| 36.3.2 | Octo-SPI interface block diagram | 1931 |
| 36.3.3 | Octo-SPI interface resets | 1932 |
| 36.3.4 | Octo-SPI interface memory | 1933 |
| 36.3.5 | OCTOSPI1/2 description | 1934 |
| 36.3.6 | OCTOSPIM description | 1934 |
| 36.3.7 | OTFDEC1/2 description | 1934 |
| 36.3.8 | DLYBOS1/2 description | 1934 |
| 36.3.9 | Octo-SPI interface interrupts | 1937 |
| 36.3.10 | OCTOSPI mapping on OCTOSPI physical ports | 1937 |
| 36.3.11 | Octo-SPI interface programmable parameters | 1942 |
| 36.3.12 | Select the RX sampling strobe and configure the TX clock | 1944 |
| 36.4 | SD/eMMC interface | 1945 |
| 36.4.1 | SD/eMMC interface main features | 1946 |
| 36.4.2 | SD/eMMC interface block diagram | 1948 |
| 36.4.3 | SD/eMMC interface reset | 1949 |
| 36.4.4 | SDMMC1/2 description | 1949 |
| 36.4.5 | DLYBSD1/2 description | 1950 |
| 36.4.6 | SD/eMMC interface interrupts | 1950 |
| 36.4.7 | SD/eMMC interface programmable parameters | 1950 |
| 36.4.8 | Guidelines for selecting the RX sampling clock | 1952 |
| 37 | Flexible memory controller (FMC) | 1955 |
| 37.1 | FMC main features | 1955 |
| 37.2 | FMC implementation | 1956 |
| 37.3 | FMC block diagram | 1956 |
| 37.4 | FMC internal signals | 1957 |
| 37.5 | AHB interface | 1957 |
| 37.6 | AXI interface | 1958 |
| 37.6.1 | Supported memories and transactions | 1958 |
| 37.7 | External device address mapping | 1959 |
| 37.7.1 | NOR/PSRAM address mapping | 1959 |
| 37.7.2 | NAND flash memory address mapping | 1960 |
| 37.8 | FMC security and isolation | 1961 |
| 37.9 | FMC RIF registers | 1964 |
| 37.9.1 | FMC security configuration register (FMC_SECCFGR) | 1964 |
| 37.9.2 | FMC security configuration register (FMC_PRIVCFGR) | 1965 |
| 37.9.3 | FMC CID configuration lock register (FMC_RCFGLOCKR) | 1966 |
| 37.9.4 | FMC resource x CID register (FMC_CIDCFGRx) | 1967 |
| 37.9.5 | FMC resource x semaphore control register (FMC_SEMCRx) | 1968 |
| 37.10 | NOR flash/PSRAM controller | 1970 |
| 37.10.1 | External memory interface signals | 1971 |
| 37.10.2 | Supported memories and transactions | 1973 |
| 37.10.3 | General timing rules . . . . . | 1975 |
| 37.10.4 | NOR flash/PSRAM controller asynchronous transactions . . . . . | 1975 |
| 37.10.5 | Synchronous transactions . . . . . | 1994 |
| 37.10.6 | NOR/PSRAM controller registers . . . . . | 2000 |
| 37.11 | NAND flash controller . . . . . | 2013 |
| 37.11.1 | External memory interface signals . . . . . | 2014 |
| 37.11.2 | NAND flash supported memories and transactions . . . . . | 2015 |
| 37.11.3 | Timing diagrams for NAND flash memory . . . . . | 2015 |
| 37.11.4 | NAND flash operations . . . . . | 2017 |
| 37.11.5 | NAND flash prewait function . . . . . | 2018 |
| 37.11.6 | NAND ECC controller . . . . . | 2018 |
| 37.11.7 | FMC command sequencer . . . . . | 2021 |
| 37.11.8 | NAND flash controller interrupt . . . . . | 2028 |
| 37.11.9 | NAND flash controller registers . . . . . | 2029 |
| 37.12 | FMC register map . . . . . | 2053 |
| 38 | Octo-SPI interface (OCTOSPI) . . . . . | 2058 |
| 38.1 | Introduction . . . . . | 2058 |
| 38.2 | OCTOSPI main features . . . . . | 2058 |
| 38.3 | OCTOSPI implementation . . . . . | 2059 |
| 38.4 | OCTOSPI functional description . . . . . | 2060 |
| 38.4.1 | OCTOSPI block diagram . . . . . | 2060 |
| 38.4.2 | OCTOSPI pins and internal signals . . . . . | 2061 |
| 38.4.3 | OCTOSPI interface to memory modes . . . . . | 2062 |
| 38.4.4 | OCTOSPI regular-command protocol . . . . . | 2062 |
| 38.4.5 | OCTOSPI regular-command protocol signal interface . . . . . | 2066 |
| 38.4.6 | HyperBus protocol . . . . . | 2069 |
| 38.4.7 | Specific features . . . . . | 2073 |
| 38.4.8 | OCTOSPI operating mode introduction . . . . . | 2075 |
| 38.4.9 | OCTOSPI indirect mode . . . . . | 2075 |
| 38.4.10 | OCTOSPI automatic status-polling mode . . . . . | 2077 |
| 38.4.11 | OCTOSPI memory-mapped mode . . . . . | 2078 |
| 38.4.12 | OCTOSPI configuration introduction . . . . . | 2078 |
| 38.4.13 | OCTOSPI system configuration . . . . . | 2078 |
| 38.4.14 | OCTOSPI device configuration . . . . . | 2079 |
| 38.4.15 | OCTOSPI regular-command mode configuration . . . . . | 2081 |
| 38.4.16 | OCTOSPI HyperBus protocol configuration . . . . . | 2084 |
| 38.4.17 | OCTOSPI error management . . . . . | 2084 |
| 38.4.18 | OCTOSPI BUSY and ABORT . . . . . | 2085 |
| 38.4.19 | OCTOSPI reconfiguration or deactivation . . . . . | 2085 |
| 38.4.20 | NCS behavior . . . . . | 2085 |
| 38.4.21 | Software control of two external memories . . . . . | 2087 |
| 38.5 | Address alignment and data number . . . . . | 2088 |
| 38.6 | OCTOSPI interrupts . . . . . | 2089 |
| 38.7 | OCTOSPI registers . . . . . | 2089 |
| 38.7.1 | OCTOSPI control register (OCTOSPI_CR) . . . . . | 2089 |
| 38.7.2 | OCTOSPI device configuration register 1 (OCTOSPI_DCR1) . . . . . | 2092 |
| 38.7.3 | OCTOSPI device configuration register 2 (OCTOSPI_DCR2) . . . . . | 2094 |
| 38.7.4 | OCTOSPI device configuration register 3 (OCTOSPI_DCR3) . . . . . | 2095 |
| 38.7.5 | OCTOSPI device configuration register 4 (OCTOSPI_DCR4) . . . . . | 2096 |
| 38.7.6 | OCTOSPI status register (OCTOSPI_SR) . . . . . | 2096 |
| 38.7.7 | OCTOSPI flag clear register (OCTOSPI_FCR) . . . . . | 2097 |
| 38.7.8 | OCTOSPI data length register (OCTOSPI_DLR) . . . . . | 2098 |
| 38.7.9 | OCTOSPI address register (OCTOSPI_AR) . . . . . | 2098 |
| 38.7.10 | OCTOSPI data register (OCTOSPI_DR) . . . . . | 2099 |
| 38.7.11 | OCTOSPI polling status mask register (OCTOSPI_PSMKR) . . . . . | 2099 |
| 38.7.12 | OCTOSPI polling status match register (OCTOSPI_PSMAR) . . . . . | 2100 |
| 38.7.13 | OCTOSPI polling interval register (OCTOSPI_PIR) . . . . . | 2100 |
| 38.7.14 | OCTOSPI communication configuration register (OCTOSPI_CCR) . . . . . | 2100 |
| 38.7.15 | OCTOSPI timing configuration register (OCTOSPI_TCR) . . . . . | 2102 |
| 38.7.16 | OCTOSPI instruction register (OCTOSPI_IR) . . . . . | 2103 |
| 38.7.17 | OCTOSPI alternate bytes register (OCTOSPI_ABR) . . . . . | 2103 |
| 38.7.18 | OCTOSPI low-power timeout register (OCTOSPI_LPTR) . . . . . | 2104 |
| 38.7.19 | OCTOSPI wrap communication configuration register (OCTOSPI_WPCCR) . . . . . | 2104 |
| 38.7.20 | OCTOSPI wrap timing configuration register (OCTOSPI_WPTCR) . . . . . | 2106 |
| 38.7.21 | OCTOSPI wrap instruction register (OCTOSPI_WPIR) . . . . . | 2107 |
| 38.7.22 | OCTOSPI wrap alternate bytes register (OCTOSPI_WPABR) . . . . . | 2107 |
| 38.7.23 | OCTOSPI write communication configuration register (OCTOSPI_WCCR) . . . . . | 2108 |
| 38.7.24 | OCTOSPI write timing configuration register (OCTOSPI_WTCR) . . . . . | 2110 |
| 38.7.25 | OCTOSPI write instruction register (OCTOSPI_WIR) . . . . . | 2110 |
| 38.7.26 | OCTOSPI write alternate bytes register (OCTOSPI_WABR) . . . . . | 2111 |
| 38.7.27 | OCTOSPI HyperBus latency configuration register (OCTOSPI_HLCR) ..... | 2111 |
| 38.7.28 | OCTOSPI hardware configuration register 2 (OCTOSPI_HWCFGR2) ..... | 2112 |
| 38.7.29 | OCTOSPI hardware configuration register (OCTOSPI_HWCFGR) ..... | 2113 |
| 38.7.30 | OCTOSPI version register (OCTOSPI_VERR) ..... | 2113 |
| 38.7.31 | OCTOSPI identification register (OCTOSPI_IDR) ..... | 2114 |
| 38.7.32 | OCTOSPI hardware magic identification register (OCTOSPI_MIDR) ..... | 2114 |
| 38.7.33 | OCTOSPI register map ..... | 2114 |
| 39 | Octo-SPI I/O manager (OCTOSPIM) ..... | 2118 |
| 39.1 | Introduction ..... | 2118 |
| 39.2 | OCTOSPIM main features ..... | 2118 |
| 39.3 | OCTOSPIM functional description ..... | 2118 |
| 39.3.1 | OCTOSPIM block diagram ..... | 2118 |
| 39.3.2 | OCTOSPIM input/output pins ..... | 2119 |
| 39.3.3 | OCTOSPIM matrix ..... | 2119 |
| 39.3.4 | OCTOSPIM multiplexed mode ..... | 2120 |
| 39.4 | Use cases description ..... | 2120 |
| 39.4.1 | Two OCTOSPIs direct mode ..... | 2121 |
| 39.4.2 | OCTOSPI swapped mode ..... | 2121 |
| 39.4.3 | Two OCTOSPIs multiplexed mode to Port 1 accessing two external memories ..... | 2122 |
| 39.4.4 | Two OCTOSPIs multiplexed mode to Port 2 accessing two external memories ..... | 2123 |
| 39.4.5 | OCTOSPI1 and OCTOSPI2 drive a single external memory ..... | 2124 |
| 39.4.6 | A single OCTOSPI drives two external memories ..... | 2124 |
| 39.5 | OCTOSPIM registers ..... | 2126 |
| 39.5.1 | OCTOSPIM control register (OCTOSPIM_CR) ..... | 2126 |
| 39.5.2 | OCTOSPIM hardware configuration register (OCTOSPIM_HWCFGR) ..... | 2127 |
| 39.5.3 | OCTOSPIM version register (OCTOSPIM_VERR) ..... | 2127 |
| 39.5.4 | OCTOSPIM identification (OCTOSPIM_IDR) ..... | 2128 |
| 39.5.5 | OCTOSPIM size identification register (OCTOSPIM_SIDR) ..... | 2128 |
| 39.5.6 | OCTOSPIM register map ..... | 2128 |
| 40 | Secure digital input/output MultiMediaCard interface (SDMMC) .. | 2130 |
| 40.1 | SDMMC main features ..... | 2130 |
| 40.2 | SDMMC implementation | 2130 |
| 40.3 | SDMMC bus topology | 2131 |
| 40.4 | SDMMC operation modes | 2133 |
| 40.5 | SDMMC functional description | 2134 |
| 40.5.1 | SDMMC block diagram | 2134 |
| 40.5.2 | SDMMC pins and internal signals | 2134 |
| 40.5.3 | General description | 2135 |
| 40.5.4 | SDMMC adapter | 2137 |
| 40.5.5 | SDMMC AHB slave interface | 2159 |
| 40.5.6 | SDMMC AHB master interface | 2160 |
| 40.5.7 | AHB and SDMMC_CK clock relation | 2163 |
| 40.6 | Card functional description | 2164 |
| 40.6.1 | SD I/O mode | 2164 |
| 40.6.2 | CMD12 send timing | 2172 |
| 40.6.3 | Sleep (CMD5) | 2176 |
| 40.6.4 | Interrupt mode (Wait-IRQ) | 2177 |
| 40.6.5 | Boot operation | 2178 |
| 40.6.6 | Response R1b handling | 2181 |
| 40.6.7 | Reset and card cycle power | 2182 |
| 40.7 | Hardware flow control | 2183 |
| 40.7.1 | Hardware flow control during data transfer | 2183 |
| 40.7.2 | Block gap hardware flow control | 2184 |
| 40.8 | Ultra-high-speed phase I (UHS-I) voltage switch | 2185 |
| 40.9 | SDMMC interrupts | 2188 |
| 40.10 | SDMMC registers | 2190 |
| 40.10.1 | SDMMC power control register (SDMMC_POWER) | 2190 |
| 40.10.2 | SDMMC clock control register (SDMMC_CLKCR) | 2191 |
| 40.10.3 | SDMMC argument register (SDMMC_ARGR) | 2193 |
| 40.10.4 | SDMMC command register (SDMMC_CMDR) | 2193 |
| 40.10.5 | SDMMC command response register (SDMMC_RESPCMDR) | 2195 |
| 40.10.6 | SDMMC response x register (SDMMC_RESPxR) | 2196 |
| 40.10.7 | SDMMC data timer register (SDMMC_DTIMER) | 2196 |
| 40.10.8 | SDMMC data length register (SDMMC_DLENR) | 2197 |
| 40.10.9 | SDMMC data control register (SDMMC_DCTRL) | 2198 |
| 40.10.10 | SDMMC data counter register (SDMMC_DCNTR) | 2199 |
| 40.10.11 | SDMMC status register (SDMMC_STAR) | 2200 |
| 40.10.12 | SDMMC interrupt clear register (SDMMC_ICR) | 2203 |
| 40.10.13 | SDMMC mask register (SDMMC_MASKR) | 2205 |
| 40.10.14 | SDMMC acknowledgment timer register (SDMMC_ACKTIMER) | 2208 |
| 40.10.15 | SDMMC data FIFO threshold register (SDMMC_FIFOTHRR) | 2208 |
| 40.10.16 | SDMMC DMA control register (SDMMC_IDMACTRLR) | 2209 |
| 40.10.17 | SDMMC IDMA buffer size register (SDMMC_IDMABSIZER) | 2209 |
| 40.10.18 | SDMMC IDMA buffer base address register (SDMMC_IDMABASER) | 2210 |
| 40.10.19 | SDMMC IDMA linked list address register (SDMMC_IDMALAR) | 2210 |
| 40.10.20 | SDMMC IDMA linked list memory base register (SDMMC_IDMABAR) | 2211 |
| 40.10.21 | SDMMC data FIFO registers x (SDMMC_FIFORx) | 2212 |
| 40.10.22 | SDMMC hardware configuration register 1 (SDMMC_HWCFG1) | 2212 |
| 40.10.23 | SDMMC version register (SDMMC_VERR) | 2213 |
| 40.10.24 | SDMMC identification register (SDMMC_IPIDR) | 2213 |
| 40.10.25 | SDMMC size identification register (SDMMC_SIDR) | 2213 |
| 40.10.26 | SDMMC register map | 2214 |
| 41 | Delay block (DLYB) | 2217 |
| 41.1 | Introduction | 2217 |
| 41.2 | DLYB main features | 2217 |
| 41.3 | DLYB implementation | 2217 |
| 41.4 | DLYB functional description | 2217 |
| 41.4.1 | DLYB diagram | 2217 |
| 41.4.2 | DLYB internal signals | 2219 |
| 41.4.3 | General description | 2221 |
| 41.4.4 | Lock mode procedure | 2222 |
| 41.4.5 | Bypass mode procedure | 2222 |
| 42 | Analog-to-digital converters (ADC) | 2223 |
| 42.1 | Introduction | 2223 |
| 42.2 | ADC main features | 2223 |
| 42.3 | ADC implementation | 2225 |
| 42.4 | ADC functional description | 2226 |
| 42.4.1 | ADC block diagram | 2226 |
| 42.4.2 | ADC pins and internal signals | 2227 |
| 42.4.3 | ADC clocks | 2232 |
| 42.4.4 | ADC connectivity | 2234 |
| 42.4.5 | Slave AHB interface | 2237 |
| 42.4.6 | ADC Deep-power-down mode (DEEPPWD) | 2237 |
| 42.4.7 | Single-ended and differential input channels | 2237 |
| 42.4.8 | Calibration (ADCAL, CALADDOS, ADC_CALFACT) | 2238 |
| 42.4.9 | ADC on-off control (ADEN, ADDIS, ADRDY) | 2240 |
| 42.4.10 | Constraints when writing the ADC control bits | 2241 |
| 42.4.11 | Channel selection (SQRx, JSQRx) | 2241 |
| 42.4.12 | Channel preselection register (ADC_PCSEL) | 2242 |
| 42.4.13 | Channel-wise programmable sampling time (SMPR1, SMPR2) | 2243 |
| 42.4.14 | Single conversion mode | 2244 |
| 42.4.15 | Continuous conversion mode (CONT = 1) | 2245 |
| 42.4.16 | Starting conversions (ADSTART, JADSTART) | 2246 |
| 42.4.17 | Timing | 2247 |
| 42.4.18 | Stopping an ongoing conversion (ADSTP, JADSTP) | 2248 |
| 42.4.19 | Conversion on external trigger and trigger polarity (EXTSEL, EXTEN, JEXTSEL, JEXTEN) | 2249 |
| 42.4.20 | Injected channel management | 2251 |
| 42.4.21 | Discontinuous mode (DISCEN, DISCNUM, JDISCEN) | 2252 |
| 42.4.22 | Programmable resolution (RES) - fast conversion mode | 2254 |
| 42.4.23 | End of conversion and end of sampling phase (EOC, JEOC, EOSMP) | 2254 |
| 42.4.24 | End of conversion sequence (EOS, JEOS) | 2254 |
| 42.4.25 | Timing diagram examples (single/continuous modes, hardware/software triggers) | 2255 |
| 42.4.26 | Data management | 2257 |
| 42.4.27 | Managing conversions using the MDF | 2265 |
| 42.4.28 | Dynamic low-power features | 2266 |
| 42.4.29 | Analog window watchdog (AWD1EN, JAWD1EN, AWD1SGL, AWD1CH, AWDCH of ADC_AWD2CR and ADC_AWD3CR, HTR, LTR, AWDFILT) | 2270 |
| 42.4.30 | Oversampler | 2275 |
| 42.4.31 | VBAT supply monitoring | 2281 |
| 42.4.32 | Monitoring the internal voltage reference | 2282 |
| 42.4.33 | Monitoring the supply voltage | 2284 |
| 42.5 | ADC interrupts | 2284 |
| 42.6 | ADC registers (for each ADC) | 2285 |
| 42.6.1 | ADC interrupt and status register (ADC_ISR) | 2285 |
| 42.6.2 | ADC interrupt enable register (ADC_IER) ..... | 2287 |
| 42.6.3 | ADC control register (ADC_CR) ..... | 2289 |
| 42.6.4 | ADC configuration register (ADC_CFGR1) ..... | 2292 |
| 42.6.5 | ADC configuration register 2 (ADC_CFGR2) ..... | 2295 |
| 42.6.6 | ADC sample time register 1 (ADC_SMPR1) ..... | 2298 |
| 42.6.7 | ADC sample time register 2 (ADC_SMPR2) ..... | 2299 |
| 42.6.8 | ADC channel preselection register (ADC_PCSEL) ..... | 2299 |
| 42.6.9 | ADC regular sequence register 1 (ADC_SQR1) ..... | 2300 |
| 42.6.10 | ADC regular sequence register 2 (ADC_SQR2) ..... | 2301 |
| 42.6.11 | ADC regular sequence register 3 (ADC_SQR3) ..... | 2302 |
| 42.6.12 | ADC regular sequence register 4 (ADC_SQR4) ..... | 2303 |
| 42.6.13 | ADC regular data register (ADC_DR) ..... | 2303 |
| 42.6.14 | ADC injected sequence register (ADC_JSQR) ..... | 2304 |
| 42.6.15 | ADC offset y configuration register (ADC_OFCFGRy) ..... | 2305 |
| 42.6.16 | ADC offset y register (ADC_OFRy) ..... | 2306 |
| 42.6.17 | ADC gain compensation register (ADC_GCOMP) ..... | 2307 |
| 42.6.18 | ADC injected channel y data register (ADC_JDRy) ..... | 2308 |
| 42.6.19 | ADC analog watchdog 2 configuration register (ADC_AWD2CR) ... | 2308 |
| 42.6.20 | ADC analog watchdog 3 configuration register (ADC_AWD3CR) ... | 2309 |
| 42.6.21 | ADC analog watchdog 1 lower threshold register (ADC_AWD1LTR) | 2309 |
| 42.6.22 | ADC analog watchdog 1 higher threshold register (ADC_AWD1HTR) ..... | 2310 |
| 42.6.23 | ADC analog watchdog 2 lower threshold register (ADC_AWD2LTR) | 2310 |
| 42.6.24 | ADC analog watchdog 2 higher threshold register (ADC_AWD2HTR) ..... | 2311 |
| 42.6.25 | ADC analog watchdog 3 lower threshold register (ADC_AWD3LTR) | 2311 |
| 42.6.26 | ADC analog watchdog 3 higher threshold register (ADC_AWD3HTR) ..... | 2312 |
| 42.6.27 | ADC differential mode selection register (ADC_DIFSEL) ..... | 2312 |
| 42.6.28 | ADC calibration factors (ADC_CALFACT) ..... | 2313 |
| 42.6.29 | ADC option register (ADC_OR) ..... | 2314 |
| 42.7 | ADC common registers ..... | 2315 |
| 42.7.1 | ADC common status register (ADCC_CSR) ..... | 2315 |
| 42.7.2 | ADC common control register (ADCC_CCR) ..... | 2316 |
| 42.7.3 | ADC hardware configuration register (ADCC_HWCFGR1) ..... | 2317 |
| 42.7.4 | ADC version register (ADCC_VERR) ..... | 2318 |
| 42.7.5 | ADC identification register (ADCC_IPIDR) ..... | 2319 |
| 42.7.6 | ADC size identification register (ADCC_SIDR) ..... | 2319 |
| 42.8 | ADC register map ..... | 2320 |
| 43 | Digital temperature sensor (DTS) ..... | 2324 |
| 43.1 | Introduction ..... | 2324 |
| 43.2 | DTS main features ..... | 2324 |
| 43.3 | DTS functional description ..... | 2325 |
| 43.3.1 | DTS block diagram ..... | 2325 |
| 43.3.2 | DTS pins and internal signals ..... | 2325 |
| 43.3.3 | DTS reset and clocks ..... | 2326 |
| 43.3.4 | DTS serial data adapter (SDA) ..... | 2327 |
| 43.3.5 | Alarms ..... | 2333 |
| 43.3.6 | Main APB programming routines ..... | 2335 |
| 43.3.7 | Temperature sensor configuration ..... | 2338 |
| 43.4 | DTS interrupts ..... | 2340 |
| 43.5 | DTS registers ..... | 2341 |
| 43.5.1 | DTS PVT common registers ..... | 2341 |
| 43.5.2 | PVT IRQ registers ..... | 2343 |
| 43.5.3 | TS common registers ..... | 2347 |
| 43.5.4 | TS individual registers ..... | 2352 |
| 43.5.5 | DTS register map ..... | 2358 |
| 44 | Voltage reference buffer (VREFBUF) ..... | 2363 |
| 44.1 | Introduction ..... | 2363 |
| 44.2 | VREFBUF implementation ..... | 2363 |
| 44.3 | VREFBUF functional description ..... | 2363 |
| 44.4 | VREFBUF trimming ..... | 2364 |
| 44.5 | VREFBUF power sequence ..... | 2365 |
| 44.6 | VREFBUF registers ..... | 2366 |
| 44.6.1 | VREFBUF control and status register (VREFBUF_CSR) ..... | 2366 |
| 44.6.2 | VREFBUF calibration control register (VREFBUF_CCR) ..... | 2367 |
| 44.6.3 | VREFBUF register map ..... | 2367 |
| 45 | Multi-function digital filter (MDF) ..... | 2368 |
| 45.1 | Introduction ..... | 2368 |
| 45.2 | MDF main features ..... | 2369 |
| 45.3 | MDF implementation | 2369 |
| 45.4 | MDF functional description | 2371 |
| 45.4.1 | MDF block diagram | 2371 |
| 45.4.2 | MDF pins and internal signals | 2371 |
| 45.4.3 | Serial input interfaces (SITF) | 2373 |
| 45.4.4 | ADC slave interface (ADCITF) | 2378 |
| 45.4.5 | Clock generator (CKGEN) | 2379 |
| 45.4.6 | Bitstream matrix (BSMX) | 2381 |
| 45.4.7 | Short-circuit detectors (SCD) | 2382 |
| 45.4.8 | Digital filter processing (DFLT) | 2384 |
| 45.4.9 | Out-of-limit detector (OLD) | 2394 |
| 45.4.10 | Digital filter acquisition modes | 2397 |
| 45.4.11 | Start-up sequence examples | 2406 |
| 45.4.12 | Break interface | 2408 |
| 45.4.13 | Data transfer to memory | 2409 |
| 45.4.14 | Autonomous mode | 2414 |
| 45.4.15 | Register protection | 2415 |
| 45.5 | MDF low-power modes | 2416 |
| 45.6 | MDF interrupts | 2416 |
| 45.7 | MDF application informations | 2418 |
| 45.7.1 | MDF configuration examples for audio capture | 2418 |
| 45.7.2 | Programming examples | 2419 |
| 45.7.3 | Connection examples | 2421 |
| 45.7.4 | Global frequency response | 2422 |
| 45.7.5 | Total MDF gain | 2423 |
| 45.8 | MDF registers | 2427 |
| 45.8.1 | MDF global control register (MDF_GCR) | 2428 |
| 45.8.2 | MDF clock generator control register (MDF_CKGCR) | 2428 |
| 45.8.3 | MDF serial interface control register x (MDF_SITFxCR) | 2431 |
| 45.8.4 | MDF bitstream matrix control register x (MDF_BSMXxCR) | 2432 |
| 45.8.5 | MDF digital filter control register x (MDF_DFLTxCr) | 2433 |
| 45.8.6 | MDF digital filter configuration register x (MDF_DFLTxCICR) | 2435 |
| 45.8.7 | MDF reshape filter configuration register x (MDF_DFLTxRSFR) | 2436 |
| 45.8.8 | MDF integrator configuration register x (MDF_DFLTxINTR) | 2437 |
| 45.8.9 | MDF out-of limit detector control register x (MDF_OLDxCr) | 2438 |
| 45.8.10 | MDF OLDx low threshold register x (MDF_OLDxTHLR) | 2440 |
| 45.8.11 | MDF OLDx high threshold register x (MDF_OLDxTHHR) . . . . . | 2440 |
| 45.8.12 | MDF delay control register x (MDF_DLYxCR) . . . . . | 2441 |
| 45.8.13 | MDF short circuit detector control register x (MDF_SCDxCR) . . . . . | 2441 |
| 45.8.14 | MDF DFLT0 interrupt enable register 0 (MDF_DFLT0IER) . . . . . | 2442 |
| 45.8.15 | MDF DFLTx interrupt enable register x (MDF_DFLTxIER) . . . . . | 2444 |
| 45.8.16 | MDF DFLT0 interrupt status register 0 (MDF_DFLT0ISR) . . . . . | 2445 |
| 45.8.17 | MDF DFLTx interrupt status register x (MDF_DFLTxISR) . . . . . | 2447 |
| 45.8.18 | MDF offset error compensation control register x (MDF_OECxCR) . . . . . | 2448 |
| 45.8.19 | MDF snapshot data register x (MDF_SNPSxDR) . . . . . | 2449 |
| 45.8.20 | MDF digital filter data register x (MDF_DFLTxDR) . . . . . | 2449 |
| 45.8.21 | MDF hardware configuration register (MDF_HWCFGR) . . . . . | 2450 |
| 45.8.22 | MDF version register (MDF_VERR) . . . . . | 2451 |
| 45.8.23 | MDF identification register (MDF_IPIDR) . . . . . | 2451 |
| 45.8.24 | MDF size identification register (MDF_SIDR) . . . . . | 2451 |
| 45.8.25 | MDF register map . . . . . | 2452 |
| 46 | Audio digital filter (ADF) . . . . . | 2455 |
| 46.1 | Introduction . . . . . | 2455 |
| 46.2 | ADF main features . . . . . | 2455 |
| 46.3 | ADF implementation . . . . . | 2456 |
| 46.4 | ADF functional description . . . . . | 2457 |
| 46.4.1 | ADF block diagram . . . . . | 2457 |
| 46.4.2 | ADF pins and internal signals . . . . . | 2457 |
| 46.4.3 | Serial input interface (SITF) . . . . . | 2458 |
| 46.4.4 | ADC slave interface (ADCITF) . . . . . | 2462 |
| 46.4.5 | Clock generator (CKGEN) . . . . . | 2463 |
| 46.4.6 | Bitstream matrix (BSMX) . . . . . | 2465 |
| 46.4.7 | Digital filter processing (DFLT) . . . . . | 2466 |
| 46.4.8 | Digital filter acquisition modes . . . . . | 2476 |
| 46.4.9 | Start-up sequence examples . . . . . | 2484 |
| 46.4.10 | Sound activity detection (SAD) . . . . . | 2485 |
| 46.4.11 | Data transfer to memory . . . . . | 2493 |
| 46.4.12 | Autonomous mode . . . . . | 2496 |
| 46.4.13 | Register protection . . . . . | 2496 |
| 46.5 | ADF low-power modes . . . . . | 2497 |
| 46.6 | ADF interrupts . . . . . | 2497 |
| 46.7 | ADF application information | 2499 |
| 46.7.1 | ADF configuration examples for audio capture | 2499 |
| 46.7.2 | Programming examples | 2500 |
| 46.7.3 | Connection examples | 2502 |
| 46.7.4 | Global frequency response | 2503 |
| 46.7.5 | Total ADF gain | 2504 |
| 46.7.6 | How to compute SAD thresholds | 2507 |
| 46.8 | ADF registers | 2511 |
| 46.8.1 | ADF global control register (ADF_GCR) | 2511 |
| 46.8.2 | ADF clock generator control register (ADF_CKGCR) | 2512 |
| 46.8.3 | ADF serial interface control register 0 (ADF_SITF0CR) | 2514 |
| 46.8.4 | ADF bitstream matrix control register 0 (ADF_BSMX0CR) | 2515 |
| 46.8.5 | ADF digital filter control register 0 (ADF_DFLT0CR) | 2516 |
| 46.8.6 | ADF digital filter configuration register 0 (ADF_DFLT0CICR) | 2518 |
| 46.8.7 | ADF reshape filter configuration register 0 (ADF_DFLT0RSFR) | 2519 |
| 46.8.8 | ADF delay control register 0 (ADF_DLY0CR) | 2520 |
| 46.8.9 | ADF DFLT0 interrupt enable register (ADF_DFLT0IER) | 2521 |
| 46.8.10 | ADF DFLT0 interrupt status register 0 (ADF_DFLT0ISR) | 2522 |
| 46.8.11 | ADF SAD control register (ADF_SADCR) | 2523 |
| 46.8.12 | ADF SAD configuration register (ADF_SADCFGR) | 2525 |
| 46.8.13 | ADF SAD sound level register (ADF_SADSDLVR) | 2526 |
| 46.8.14 | ADF SAD ambient noise level register (ADF_SADANLVR) | 2527 |
| 46.8.15 | ADF digital filter data register 0 (ADF_DFLT0DR) | 2527 |
| 46.8.16 | ADF hardware configuration register (ADF_HWCFGR) | 2527 |
| 46.8.17 | ADF version register (ADF_VERR) | 2528 |
| 46.8.18 | ADF identification register (ADF_IPIDR) | 2529 |
| 46.8.19 | ADF size identification register (ADF_SIDR) | 2529 |
| 46.8.20 | ADF register map | 2529 |
| 47 | Camera subsystem | 2532 |
| 47.1 | Introduction | 2532 |
| 47.2 | Camera path main features | 2532 |
| 47.2.1 | DCMI path main features | 2532 |
| 47.2.2 | DCMIPP path main features | 2533 |
| 47.3 | Camera subsystem implementation | 2534 |
| 47.3.1 | Hardware settings | 2534 |
| 47.4 | Camera subsystem functional description | 2535 |
| 47.4.1 | Camera subsystem block diagram | 2535 |
| 47.4.2 | Camera subsystem pins and external signal interface | 2535 |
| 47.4.3 | Camera subsystem reset and clocks | 2536 |
| 47.4.4 | Camera subsystem security | 2536 |
| 47.5 | Camera subsystem programmable parameters | 2538 |
| 47.5.1 | Low-resolution parallel camera and DCMI | 2538 |
| 47.5.2 | High-resolution parallel camera and DCMIPP | 2539 |
| 47.5.3 | High-resolution CSI2 camera and DCMIPP | 2539 |
| 47.5.4 | Sensors over target resolution | 2540 |
| 47.5.5 | Sensors over target pixel rate | 2540 |
| 47.5.6 | Double sensors | 2541 |
| 47.6 | Camera subsystem interrupts | 2541 |
| 47.7 | Camera subsystem registers | 2541 |
| 48 | Digital camera interface (DCMI) | 2542 |
| 48.1 | Introduction | 2542 |
| 48.2 | DCMI main features | 2542 |
| 48.3 | DCMI functional description | 2542 |
| 48.3.1 | DCMI block diagram | 2543 |
| 48.3.2 | DCMI pins and internal signals | 2543 |
| 48.3.3 | DCMI clocks | 2544 |
| 48.3.4 | DCMI DMA interface | 2544 |
| 48.3.5 | DCMI physical interface | 2544 |
| 48.3.6 | DCMI synchronization | 2546 |
| 48.3.7 | DCMI capture modes | 2548 |
| 48.3.8 | DCMI crop feature | 2549 |
| 48.3.9 | DCMI JPEG format | 2550 |
| 48.3.10 | DCMI FIFO | 2550 |
| 48.3.11 | DCMI data format description | 2551 |
| 48.4 | DCMI interrupts | 2553 |
| 48.5 | DCMI registers | 2553 |
| 48.5.1 | DCMI control register (DCMI_CR) | 2553 |
| 48.5.2 | DCMI status register (DCMI_SR) | 2556 |
| 48.5.3 | DCMI raw interrupt status register (DCMI_RIS) | 2556 |
| 48.5.4 | DCMI interrupt enable register (DCMI_IER) | 2557 |
| 48.5.5 | DCMI masked interrupt status register (DCMI_MIS) . . . . . | 2558 |
| 48.5.6 | DCMI interrupt clear register (DCMI_ICR) . . . . . | 2559 |
| 48.5.7 | DCMI embedded synchronization code register (DCMI_ESCR) . . . . . | 2560 |
| 48.5.8 | DCMI embedded synchronization unmask register (DCMI_ESUR) . . . . . | 2560 |
| 48.5.9 | DCMI crop window start (DCMI_CWSTRT) . . . . . | 2561 |
| 48.5.10 | DCMI crop window size (DCMI_CWSIZE) . . . . . | 2562 |
| 48.5.11 | DCMI data register (DCMI_DR) . . . . . | 2562 |
| 48.5.12 | DCMI hardware configuration register (DCMI_HWCFGR) . . . . . | 2563 |
| 48.5.13 | DCMI version register (DCMI_VERR) . . . . . | 2563 |
| 48.5.14 | DCMI identification register (DCMI_IPIDR) . . . . . | 2563 |
| 48.5.15 | DCMI size identification register (DCMI_SIDR) . . . . . | 2564 |
| 48.5.16 | DCMI register map . . . . . | 2564 |
| 49 | Digital camera interface pixel pipeline (DCMIPP) . . . . . | 2566 |
| 49.1 | Introduction . . . . . | 2566 |
| 49.2 | DCMIPP main features . . . . . | 2569 |
| 49.3 | DCMIPP functional description . . . . . | 2571 |
| 49.3.1 | DCMIPP block diagram . . . . . | 2571 |
| 49.3.2 | DCMIPP pads and internal signals . . . . . | 2572 |
| 49.3.3 | DCMIPP reset and clocks . . . . . | 2572 |
| 49.3.4 | DCMIPP maximum resolution . . . . . | 2575 |
| 49.3.5 | DCMIPP minimum requirements for frame structure . . . . . | 2576 |
| 49.3.6 | Description of DCMIPP pixel format support . . . . . | 2576 |
| 49.4 | DCMIPP input and flow control . . . . . | 2577 |
| 49.4.1 | Parallel input interface . . . . . | 2578 |
| 49.4.2 | Interface from CSI-2 host . . . . . | 2581 |
| 49.4.3 | Test pattern generator (TPG) . . . . . | 2581 |
| 49.4.4 | Input selection . . . . . | 2583 |
| 49.4.5 | Flow selection . . . . . | 2584 |
| 49.4.6 | Frame counter . . . . . | 2585 |
| 49.4.7 | Frame control . . . . . | 2586 |
| 49.4.8 | Pipe deactivation . . . . . | 2591 |
| 49.5 | Pipe0 (dump pipe) . . . . . | 2592 |
| 49.5.1 | Overview . . . . . | 2592 |
| 49.5.2 | Decimation . . . . . | 2593 |
| 49.5.3 | Crop/statistics selection/suppression . . . . . | 2593 |
| 49.5.4 | Header insertion . . . . . | 2594 |
| 49.5.5 | Dump counter ..... | 2595 |
| 49.6 | Pipe1 (ISP part) ..... | 2596 |
| 49.6.1 | Overview ..... | 2596 |
| 49.6.2 | Byte-to-pixel conversion ..... | 2597 |
| 49.6.3 | Statistics removal ..... | 2598 |
| 49.6.4 | Bad pixel removal ..... | 2598 |
| 49.6.5 | Input decimation ..... | 2600 |
| 49.6.6 | Statistics extraction ..... | 2601 |
| 49.6.7 | Black level calibration ..... | 2604 |
| 49.6.8 | Exposure compensation and white-balance calibration ..... | 2605 |
| 49.6.9 | Demosaicing ..... | 2606 |
| 49.6.10 | Contrast enhancement ..... | 2608 |
| 49.6.11 | Color conversion ..... | 2610 |
| 49.7 | Pipe1 (post-processing part) ..... | 2613 |
| 49.7.1 | Overview ..... | 2613 |
| 49.7.2 | Pixel 2D cropping ..... | 2613 |
| 49.7.3 | Decimation pre-downsize ..... | 2614 |
| 49.7.4 | Downsize ..... | 2615 |
| 49.7.5 | Gamma conversion ..... | 2617 |
| 49.7.6 | YUV conversion ..... | 2617 |
| 49.7.7 | Chroma down-sampling ..... | 2617 |
| 49.7.8 | Pixel packing ..... | 2618 |
| 49.7.9 | Overrun detection ..... | 2619 |
| 49.8 | Pipe2 (post-processing) ..... | 2620 |
| 49.8.1 | Overview ..... | 2620 |
| 49.8.2 | Pipe1 and Pipe2 sharing image processing functions ..... | 2620 |
| 49.9 | Application use cases ..... | 2621 |
| 49.9.1 | Parallel interface camera sensor module ..... | 2621 |
| 49.9.2 | CSI2 camera sensor module ..... | 2622 |
| 49.9.3 | Force data type format from CSI-2 data flow (pixel pipes only) ..... | 2628 |
| 49.10 | Pixel format description ..... | 2631 |
| 49.10.1 | Parallel interface formats ..... | 2631 |
| 49.10.2 | Pixel pipe formats ..... | 2633 |
| 49.10.3 | Dump pipe formats ..... | 2634 |
| 49.10.4 | AXI IP-Plug ..... | 2636 |
| 49.11 | Shadow registers ..... | 2642 |
| 49.12 | DCMIPP low power modes | 2644 |
| 49.13 | DCMIPP interrupts | 2645 |
| 49.13.1 | Free-running DCMIPP | 2645 |
| 49.13.2 | Interrupts | 2645 |
| 49.13.3 | Event pins | 2648 |
| 49.14 | DCMIPP registers | 2649 |
| 49.14.1 | DCMIPP IP-Plug global register 1 (DCMIPP_IPGR1) | 2649 |
| 49.14.2 | DCMIPP IP-Plug global register 2 (DCMIPP_IPGR2) | 2650 |
| 49.14.3 | DCMIPP IP-Plug global register 3 (DCMIPP_IPGR3) | 2650 |
| 49.14.4 | DCMIPP IP-Plug identification register (DCMIPP_IPGR8) | 2651 |
| 49.14.5 | DCMIPP IP-Plug Clientx register 1 (DCMIPP_IPCxR1) | 2651 |
| 49.14.6 | DCMIPP IP-Plug Clientx register 2 (DCMIPP_IPCxR2) | 2652 |
| 49.14.7 | DCMIPP IP-Plug Clientx register 3 (DCMIPP_IPCxR3) | 2652 |
| 49.14.8 | DCMIPP parallel interface control register (DCMIPP_PRCR) | 2653 |
| 49.14.9 | DCMIPP parallel interface embedded synchronization code register (DCMIPP_PRESCR) | 2654 |
| 49.14.10 | DCMIPP parallel interface embedded synchronization unmask register (DCMIPP PRESUR) | 2655 |
| 49.14.11 | DCMIPP parallel interface interrupt enable register (DCMIPP_PRIER) | 2656 |
| 49.14.12 | DCMIPP parallel interface status register (DCMIPP_PRSR) | 2657 |
| 49.14.13 | DCMIPP parallel interface interrupt clear register (DCMIPP_PRFCR) | 2657 |
| 49.14.14 | DCMIPP common IP HW configuration register (DCMIPP_CMHWCFGR) | 2658 |
| 49.14.15 | DCMIPP common configuration register (DCMIPP_CMCR) | 2658 |
| 49.14.16 | DCMIPP common frame counter register (DCMIPP_CMFRCR) | 2659 |
| 49.14.17 | DCMIPP common test pattern generator configuration register 1 (DCMIPP_CMTPGCR1) | 2660 |
| 49.14.18 | DCMIPP common test pattern generator configuration register 2 (DCMIPP_CMTPGCR2) | 2660 |
| 49.14.19 | DCMIPP common interrupt enable register (DCMIPP_CMIER) | 2661 |
| 49.14.20 | DCMIPP common status register 1 (DCMIPP_CMSR1) | 2663 |
| 49.14.21 | DCMIPP common status register 2 (DCMIPP_CMSR2) | 2664 |
| 49.14.22 | DCMIPP common interrupt clear register (DCMIPP_CMFCR) | 2667 |
| 49.14.23 | DCMIPP Pipe0 HW configuration register (DCMIPP_P0HWCFGR) | 2668 |
| 49.14.24 | DCMIPP Pipe0 flow selection configuration register (DCMIPP_P0FSCR) | 2669 |
| 49.14.25 DCMIPP Pipe0 flow control configuration register (DCMIPP_P0FCTCR) ..... | 2670 |
| 49.14.26 DCMIPP Pipe0 statistic/crop start register (DCMIPP_P0SCSTR) ..... | 2671 |
| 49.14.27 DCMIPP Pipe0 statistic/crop size register (DCMIPP_P0SCSZR) ..... | 2671 |
| 49.14.28 DCMIPP Pipe0 dump counter register (DCMIPP_P0DCCNTR) ..... | 2672 |
| 49.14.29 DCMIPP Pipe0 dump limit register (DCMIPP_P0DCLMTR) ..... | 2672 |
| 49.14.30 DCMIPP Pipe0 pixel packer configuration register (DCMIPP_P0PPCR) ..... | 2673 |
| 49.14.31 DCMIPP Pipe0 pixel packer Memory0 address register 1 (DCMIPP_P0PPM0AR1) ..... | 2674 |
| 49.14.32 DCMIPP Pipe0 status Memory0 address register (DCMIPP_P0STM0AR) ..... | 2675 |
| 49.14.33 DCMIPP Pipe0 interrupt enable register (DCMIPP_P0IER) ..... | 2675 |
| 49.14.34 DCMIPP Pipe0 status register (DCMIPP_P0SR) ..... | 2676 |
| 49.14.35 DCMIPP Pipe0 interrupt clear register (DCMIPP_P0FCR) ..... | 2677 |
| 49.14.36 DCMIPP Pipe0 current flow selection configuration register (DCMIPP_P0CFSCR) ..... | 2677 |
| 49.14.37 DCMIPP Pipe0 current flow control configuration register (DCMIPP_P0CFCTCR) ..... | 2678 |
| 49.14.38 DCMIPP Pipe0 current statistic/crop start register (DCMIPP_P0CSCSTR) ..... | 2679 |
| 49.14.39 DCMIPP Pipe0 current statistic/crop size register (DCMIPP_P0CSCSZR) ..... | 2679 |
| 49.14.40 DCMIPP Pipe0 current pixel packer configuration register (DCMIPP_P0CPPCR) ..... | 2680 |
| 49.14.41 DCMIPP Pipe0 current pixel packer Memory0 address register 1 (DCMIPP_P0CPPM0AR1) ..... | 2682 |
| 49.14.42 DCMIPP Pipe0 HW configuration register (DCMIPP_PxHWCFGR) ..... | 2682 |
| 49.14.43 DCMIPP Pipe1 flow selection configuration register (DCMIPP_P1FSCR) ..... | 2683 |
| 49.14.44 DCMIPP Pipe1 stat removal configuration register (DCMIPP_P1SRCR) ..... | 2684 |
| 49.14.45 DCMIPP Pipe1 bad pixel removal control register (DCMIPP_P1BPRCR) ..... | 2685 |
| 49.14.46 DCMIPP Pipe1 bad pixel removal status register (DCMIPP_P1BPRSR) ..... | 2685 |
| 49.14.47 DCMIPP Pipe1 decimation register (DCMIPP_P1DECR) ..... | 2685 |
| 49.14.48 DCMIPP Pipe1 black level calibration control register (DCMIPP_P1BLCCR) ..... | 2686 |
| 49.14.49 DCMIPP Pipe1 exposure control register 1 (DCMIPP_P1EXCR1) ..... | 2687 |
| 49.14.50 DCMIPP Pipe1 exposure control register 2 (DCMIPP_P1EXCR2) ..... | 2687 |
| 49.14.51 DCMIPP Pipe1 statistics1 control register (DCMIPP_P1ST1CR) . . . | 2688 |
| 49.14.52 DCMIPP Pipe1 statistics 2 control register (DCMIPP_P1ST2CR) . . . | 2689 |
| 49.14.53 DCMIPP Pipe1 statistics 3 control register (DCMIPP_P1ST3CR) . . . | 2690 |
| 49.14.54 DCMIPP Pipe1 statistics window start register (DCMIPP_P1STSTR) . . . . . | 2691 |
| 49.14.55 DCMIPP Pipe1 statistics window size register (DCMIPP_P1STSZR) . . . . . | 2691 |
| 49.14.56 DCMIPP Pipe1 statistics 1 status register (DCMIPP_P1ST1SR) . . . | 2692 |
| 49.14.57 DCMIPP Pipe1 statistics 2 status register (DCMIPP_P1ST2SR) . . . | 2692 |
| 49.14.58 DCMIPP Pipe1 statistics 3 status register (DCMIPP_P1ST3SR) . . . | 2693 |
| 49.14.59 DCMIPP Pipe1 demosaicing configuration register (DCMIPP_P1DMCR) . . . . . | 2693 |
| 49.14.60 DCMIPP Pipe1 ColorConv configuration register (DCMIPP_P1CCCR) . . . . . | 2694 |
| 49.14.61 DCMIPP Pipe1 ColorConv red coefficient register 1 (DCMIPP_P1CCRR1) . . . . . | 2695 |
| 49.14.62 DCMIPP Pipe1 ColorConv red coefficient register 2 (DCMIPP_P1CCRR2) . . . . . | 2695 |
| 49.14.63 DCMIPP Pipe1 ColorConv green coefficient register 1 (DCMIPP_P1CCGR1) . . . . . | 2695 |
| 49.14.64 DCMIPP Pipe1 ColorConv green coefficient register 2 (DCMIPP_P1CCGR2) . . . . . | 2696 |
| 49.14.65 DCMIPP Pipex ColorConv blue coefficient register 1 (DCMIPP_P1CCBR1) . . . . . | 2696 |
| 49.14.66 DCMIPP Pipe1 ColorConv blue coefficient register 2 (DCMIPP_P1CCBR2) . . . . . | 2697 |
| 49.14.67 DCMIPP Pipe1 contrast control register 1 (DCMIPP_P1CTCR1) . . . | 2697 |
| 49.14.68 DCMIPP Pipe1 contrast control register 2 (DCMIPP_P1CTCR2) . . . | 2697 |
| 49.14.69 DCMIPP Pipe1 contrast control register 3 (DCMIPP_P1CTCR3) . . . | 2698 |
| 49.14.70 DCMIPP Pipex flow control configuration register (DCMIPP_PxFCTCR) . . . . . | 2699 |
| 49.14.71 DCMIPP Pipex crop window start register (DCMIPP_PxCRSTR) . . . | 2699 |
| 49.14.72 DCMIPP Pipex crop window size register (DCMIPP_PxCRSZR) . . . | 2700 |
| 49.14.73 DCMIPP Pipex decimation register (DCMIPP_PxDCCR) . . . . . | 2701 |
| 49.14.74 DCMIPP Pipex downsize configuration register (DCMIPP_PxDSCR) . . . . . | 2701 |
| 49.14.75 DCMIPP Pipex downsize ratio register (DCMIPP_PxDSRTIOR) . . . | 2702 |
| 49.14.76 DCMIPP Pipex downsize destination size register (DCMIPP_PxDSSZR) . . . . . | 2702 |
| 49.14.77 DCMIPP Pipex gamma configuration register (DCMIPP_PxGMCR) . | 2702 |
| 49.14.78 DCMIPP Pipe1 YUVConv configuration register (DCMIPP_P1YUVCR) ..... | 2703 |
| 49.14.79 DCMIPP Pipe1 YUVConv red coefficient register 1 (DCMIPP_P1YUVRR1) ..... | 2703 |
| 49.14.80 DCMIPP Pipe1 YUVConv red coefficient register 2 (DCMIPP_P1YUVRR2) ..... | 2704 |
| 49.14.81 DCMIPP Pipe1 YUVConv green coefficient register 1 (DCMIPP_P1YUVGR1) ..... | 2704 |
| 49.14.82 DCMIPP Pipe1 YUVConv green coefficient register 2 (DCMIPP_P1YUVGR2) ..... | 2705 |
| 49.14.83 DCMIPP Pipe1 YUVConv blue coefficient register 1 (DCMIPP_P1YUVBR1) ..... | 2705 |
| 49.14.84 DCMIPP Pipe1 YUV blue coefficient register 2 (DCMIPP_P1YUVBR2) ..... | 2705 |
| 49.14.85 DCMIPP Pipe1 pixel packer configuration register (DCMIPP_P1PPCR) ..... | 2706 |
| 49.14.86 DCMIPP Pipe1 pixel packer Memory0 address register 1 (DCMIPP_P1PPM0AR1) ..... | 2707 |
| 49.14.87 DCMIPP Pipex pixel packer Memory0 pitch register (DCMIPP_PxPPM0PR) ..... | 2707 |
| 49.14.88 DCMIPP Pipex status Memory0 address register (DCMIPP_PxSTM0AR) ..... | 2708 |
| 49.14.89 DCMIPP Pipex pixel packer Memory1 address register 1 (DCMIPP_PxPPM1AR1) ..... | 2708 |
| 49.14.90 DCMIPP Pipex pixel packer Memory1 pitch register (DCMIPP_PxPPM1PR) ..... | 2709 |
| 49.14.91 DCMIPP Pipex status Memory1 address register (DCMIPP_PxSTM1AR) ..... | 2709 |
| 49.14.92 DCMIPP Pipex pixel packer memory2 address register 1 (DCMIPP_PxPPM2AR1) ..... | 2709 |
| 49.14.93 DCMIPP Pipex status Memory2 address register (DCMIPP_PxSTM2AR) ..... | 2710 |
| 49.14.94 DCMIPP Pipe1 interrupt enable register (DCMIPP_P1IER) ..... | 2710 |
| 49.14.95 DCMIPP Pipe1 status register (DCMIPP_P1SR) ..... | 2711 |
| 49.14.96 DCMIPP Pipe1 interrupt clear register (DCMIPP_P1FCR) ..... | 2712 |
| 49.14.97 DCMIPP Pipe1 current flow selection configuration register (DCMIPP_P1CFSCR) ..... | 2713 |
| 49.14.98 DCMIPP Pipe1 current bad pixel removal register (DCMIPP_P1CBPRCR) ..... | 2714 |
| 49.14.99 DCMIPP Pipe1 current black level calibration control register (DCMIPP_P1CBLCCR) ..... | 2714 |
| 49.14.100 DCMIPP Pipe1 current exposure control register 1 (DCMIPP_P1CEXCR1) ..... | 2715 |
| 49.14.101DCMIPP Pipe1 current exposure control register 2 (DCMIPP_P1CEXCR2) ..... | 2716 |
| 49.14.102DCMIPP Pipe1 current statistics 1 control register (DCMIPP_P1CST1CR) ..... | 2716 |
| 49.14.103DCMIPP Pipe1 current statistics 2 control register (DCMIPP_P1CST2CR) ..... | 2717 |
| 49.14.104DCMIPP Pipe1 current statistics 3 control register (DCMIPP_P1CST3CR) ..... | 2718 |
| 49.14.105DCMIPP Pipe1 current statistics window start register (DCMIPP_P1CSTSTR) ..... | 2719 |
| 49.14.106DCMIPP Pipe1 current statistics window size register (DCMIPP_P1CSTSZR) ..... | 2720 |
| 49.14.107DCMIPP Pipe1 current ColorConv configuration register (DCMIPP_P1CCCCR) ..... | 2720 |
| 49.14.108DCMIPP Pipe1 current ColorConv red coefficient register 1 (DCMIPP_P1CCCR1) ..... | 2721 |
| 49.14.109DCMIPP Pipe1 current ColorConv red coefficient register 2 (DCMIPP_P1CCCR2) ..... | 2721 |
| 49.14.110DCMIPP Pipe1 current ColorConv green coefficient register 1 (DCMIPP_P1CCCGR1) ..... | 2722 |
| 49.14.111DCMIPP Pipe1 current ColorConv green coefficient register 2 (DCMIPP_P1CCCGR2) ..... | 2722 |
| 49.14.112DCMIPP Pipe1 current ColorConv blue coefficient register 1 (DCMIPP_P1CCCB1) ..... | 2722 |
| 49.14.113DCMIPP Pipe1 current ColorConv blue coefficient register 2 (DCMIPP_P1CCCB2) ..... | 2723 |
| 49.14.114DCMIPP Pipe1 current contrast control register 1 (DCMIPP_P1CCTCR1) ..... | 2723 |
| 49.14.115DCMIPP Pipe1 current contrast control register 2 (DCMIPP_P1CCTCR2) ..... | 2724 |
| 49.14.116DCMIPP Pipe1 current contrast control register 3 (DCMIPP_P1CCTCR3) ..... | 2724 |
| 49.14.117DCMIPP Pipe1 current flow control configuration register (DCMIPP_PxCFCTCR) ..... | 2725 |
| 49.14.118DCMIPP Pipe1 current crop window start register (DCMIPP_PxCCRSTR) ..... | 2726 |
| 49.14.119DCMIPP Pipe1 current crop window size register (DCMIPP_PxCCRSZR) ..... | 2726 |
| 49.14.120DCMIPP Pipe1 current decimation register (DCMIPP_PxCDCCR) .. | 2727 |
| 49.14.121DCMIPP Pipe1 current downsize configuration register (DCMIPP_PxCDSCR) ..... | 2728 |
| 49.14.122DCMIPP Pipe1 current downsize ratio register (DCMIPP_PxCDSRTIOR) ..... | 2728 |
| 49.14.123 | DCMIPP Pipex current downsize destination size register (DCMIPP_PxCDSSZR) . . . . . | 2729 |
| 49.14.124 | DCMIPP Pipe1 current pixel packer configuration register (DCMIPP_P1CPPCR) . . . . . | 2729 |
| 49.14.125 | DCMIPP Pipe1 current pixel packer Memory0 address register 1 (DCMIPP_P1CPPM0AR1) . . . . . | 2730 |
| 49.14.126 | DCMIPP Pipex current pixel packer Memory0 pitch register (DCMIPP_PxCPPM0PR) . . . . . | 2730 |
| 49.14.127 | DCMIPP Pipex current pixel packer Memory1 address register 1 (DCMIPP_PxCPPM1AR1) . . . . . | 2731 |
| 49.14.128 | DCMIPP Pipex current pixel packer Memory1 pitch register (DCMIPP_PxCPPM1PR) . . . . . | 2731 |
| 49.14.129 | DCMIPP Pipex current pixel packer Memory2 address register 1 (DCMIPP_PxCPPM2AR1) . . . . . | 2732 |
| 49.14.130 | DCMIPP Pipe2 flow selection configuration register (DCMIPP_P2FSCR) . . . . . | 2732 |
| 49.14.131 | DCMIPP Pipe2 pixel packer configuration register (DCMIPP_P2PPCR) . . . . . | 2733 |
| 49.14.132 | DCMIPP Pipe2 pixel packer Memory0 address register 1 (DCMIPP_P2PPM0AR1) . . . . . | 2734 |
| 49.14.133 | DCMIPP Pipe2 interrupt enable register (DCMIPP_P2IER) . . . . . | 2734 |
| 49.14.134 | DCMIPP Pipe2 status register (DCMIPP_P2SR) . . . . . | 2735 |
| 49.14.135 | DCMIPP Pipe2 interrupt clear register (DCMIPP_P2FCR) . . . . . | 2736 |
| 49.14.136 | DCMIPP Pipe2 current flow selection configuration register (DCMIPP_P2CFSCR) . . . . . | 2737 |
| 49.14.137 | DCMIPP Pipe2 current pixel packer configuration register (DCMIPP_P2CPPCR) . . . . . | 2737 |
| 49.14.138 | DCMIPP Pipe2 current pixel packer Memory0 address register 1 (DCMIPP_P2CPPM0AR1) . . . . . | 2738 |
| 49.14.139 | DCMIPP hardware configuration register 3 (DCMIPP_HWCFGR3) . . . . . | 2739 |
| 49.14.140 | DCMIPP hardware configuration register 2 (DCMIPP_HWCFGR2) . . . . . | 2739 |
| 49.14.141 | DCMIPP hardware configuration register 1 (DCMIPP_HWCFGR1) . . . . . | 2740 |
| 49.14.142 | DCMIPP version register (DCMIPP_VERR) . . . . . | 2741 |
| 49.14.143 | DCMIPP identification register (DCMIPP_IPIDR) . . . . . | 2741 |
| 49.14.144 | DCMIPP size identification register (DCMIPP_SIDR) . . . . . | 2742 |
| 49.15 | DCMIPP register map . . . . . | 2743 |
| 50 | CSI-2 Host (CSI) . . . . . | 2757 |
| 50.1 | Introduction . . . . . | 2757 |
| 50.2 | Standard and references . . . . . | 2757 |
| 50.3 | Glossary . . . . . | 2757 |
| 50.4 | CSI-2 Host main features . . . . . | 2758 |
| 50.5 | CSI-2 Host functional description . . . . . | 2758 |
| 50.5.1 | General description . . . . . | 2758 |
| 50.5.2 | System level architecture . . . . . | 2760 |
| 50.5.3 | CSI-2 Host reset and clocks . . . . . | 2761 |
| 50.5.4 | Lane merger . . . . . | 2762 |
| 50.5.5 | Clock changer . . . . . | 2763 |
| 50.5.6 | Low-level protocol (LLP) . . . . . | 2764 |
| 50.5.7 | CSI-2 Host protocol output . . . . . | 2774 |
| 50.6 | CSI-2 Host programming guide . . . . . | 2774 |
| 50.6.1 | CSI-2 PHY setup . . . . . | 2774 |
| 50.6.2 | CSI-2 Host controller setup and data reception start . . . . . | 2775 |
| 50.6.3 | Data reception stop . . . . . | 2776 |
| 50.7 | CSI-2 Host low-power modes . . . . . | 2776 |
| 50.8 | CSI-2 Host interrupts and errors . . . . . | 2776 |
| 50.8.1 | Error handling . . . . . | 2778 |
| 50.8.2 | Interrupt handling . . . . . | 2780 |
| 50.9 | CSI-2 Host registers . . . . . | 2781 |
| 50.9.1 | CSI-2 Host control register (CSI_CR) . . . . . | 2781 |
| 50.9.2 | CSI-2 Host DPHY_RX control register (CSI_PCR) . . . . . | 2783 |
| 50.9.3 | CSI-2 Host virtual channel x configuration register 1 (CSI_VCxCFGR1) . . . . . | 2784 |
| 50.9.4 | CSI-2 Host virtual channel x configuration register 2 (CSI_VCxCFGR2) . . . . . | 2786 |
| 50.9.5 | CSI-2 Host virtual channel x configuration register 3 (CSI_VCxCFGR3) . . . . . | 2787 |
| 50.9.6 | CSI-2 Host virtual channel x configuration register 4 (CSI_VCxCFGR4) . . . . . | 2788 |
| 50.9.7 | CSI-2 Host line byte x configuration register (CSI_LBxCFGR) . . . . . | 2789 |
| 50.9.8 | CSI-2 Host timer x configuration register (CSI_TIMxCFGR) . . . . . | 2790 |
| 50.9.9 | CSI-2 Host lane merger configuration register (CSI_LMCFGR) . . . . . | 2790 |
| 50.9.10 | CSI-2 Host program interrupt register (CSI_PRGITR) . . . . . | 2791 |
| 50.9.11 | CSI-2 Host watchdog register (CSI_WDR) . . . . . | 2795 |
| 50.9.12 | CSI-2 Host interrupt enable register 0 (CSI_IER0) . . . . . | 2795 |
| 50.9.13 | CSI-2 Host interrupt enable register 1 (CSI_IER1) . . . . . | 2798 |
| 50.9.14 | CSI-2 Host status register 0 (CSI_SR0) . . . . . | 2800 |
| 50.9.15 | CSI-2 Host status register 1 (CSI_SR1) ..... | 2802 |
| 50.9.16 | CSI-2 Host flag clear register 0 (CSI_FCR0) ..... | 2804 |
| 50.9.17 | CSI-2 Host flag clear register 1 (CSI_FCR1) ..... | 2805 |
| 50.9.18 | CSI-2 Host short packet data field register (CSI_SPDFR) ..... | 2806 |
| 50.9.19 | CSI-2 Host error register 1 (CSI_ERR1) ..... | 2807 |
| 50.9.20 | CSI-2 Host error register 2 (CSI_ERR2) ..... | 2808 |
| 50.9.21 | CSI-2 Host hardware configuration register (CSI_HWCFGR) .... | 2808 |
| 50.9.22 | CSI-2 Host version register (CSI_HVERR) ..... | 2809 |
| 50.9.23 | CSI-2 Host identification register (CSI_HIPIDR) ..... | 2809 |
| 50.9.24 | CSI-2 Host size identification register (CSI_HSIDR) ..... | 2810 |
| 50.10 | CSI PHY registers ..... | 2810 |
| 50.10.1 | CSI PHY reset control register (CSI_PRCR) ..... | 2810 |
| 50.10.2 | CSI PHY mode control register (CSI_PMCR) ..... | 2811 |
| 50.10.3 | CSI PHY frequency control register (CSI_PFCR) ..... | 2812 |
| 50.10.4 | CSI PHY test control register 0 (CSI_PTCR0) ..... | 2812 |
| 50.10.5 | CSI PHY test control register 1 (CSI_PTCR1) ..... | 2813 |
| 50.10.6 | CSI PHY test status register (CSI_PTSR) ..... | 2813 |
| 50.10.7 | CSI-2 Host hardware configuration register (CSI_HWCFGR) .... | 2813 |
| 50.10.8 | CSI-2 Host version register (CSI_VERR) ..... | 2814 |
| 50.10.9 | CSI-2 Host identification register (CSI_IPIDR) ..... | 2814 |
| 50.10.10 | CSI-2 Host size identification register (CSI_SIDR) ..... | 2815 |
| 50.11 | CSI-2 Host and PHY register map ..... | 2815 |
| 51 | Parallel synchronous slave interface (PSSI) ..... | 2819 |
| 51.1 | Introduction ..... | 2819 |
| 51.2 | PSSI main features ..... | 2819 |
| 51.3 | PSSI functional description ..... | 2819 |
| 51.3.1 | PSSI block diagram ..... | 2820 |
| 51.3.2 | PSSI pins and internal signals ..... | 2820 |
| 51.3.3 | PSSI clock ..... | 2821 |
| 51.3.4 | PSSI data management ..... | 2821 |
| 51.3.5 | PSSI optional control signals ..... | 2823 |
| 51.4 | PSSI interrupts ..... | 2826 |
| 51.5 | PSSI registers ..... | 2827 |
| 51.5.1 | PSSI control register (PSSI_CR) ..... | 2827 |
| 51.5.2 | PSSI status register (PSSI_SR) ..... | 2828 |
| 51.5.3 | PSSI raw interrupt status register (PSSI_RIS) ..... | 2829 |
| 51.5.4 | PSSI interrupt enable register (PSSI_IER) ..... | 2830 |
| 51.5.5 | PSSI masked interrupt status register (PSSI_MIS) ..... | 2830 |
| 51.5.6 | PSSI interrupt clear register (PSSI_ICR) ..... | 2831 |
| 51.5.7 | PSSI data register (PSSI_DR) ..... | 2831 |
| 51.5.8 | PSSI hardware configuration register (PSSI_HWCFGR) ..... | 2832 |
| 51.5.9 | PSSI version register (PSSI_VERR) ..... | 2832 |
| 51.5.10 | PSSI ID register (PSSI_IPIDR) ..... | 2833 |
| 51.5.11 | PSSI size identification register (PSSI_SIDR) ..... | 2833 |
| 51.5.12 | PSSI register map ..... | 2833 |
| 52 | Display subsystem ..... | 2835 |
| 52.1 | Introduction ..... | 2835 |
| 52.2 | Display subsystem main features ..... | 2835 |
| 52.3 | Display subsystem implementation ..... | 2836 |
| 52.4 | Display subsystem functional description ..... | 2837 |
| 52.4.1 | Display subsystem block diagram ..... | 2837 |
| 52.4.2 | Display subsystem pins and external signal interface ..... | 2837 |
| 52.4.3 | Display subsystem clocks ..... | 2838 |
| 52.4.4 | Display subsystem security ..... | 2838 |
| 52.5 | Display subsystem programmable parameters ..... | 2844 |
| 52.5.1 | Parallel-interface display ..... | 2845 |
| 52.5.2 | LVDS display ..... | 2846 |
| 52.5.3 | DSI display ..... | 2847 |
| 52.5.4 | Three panel interfaces in parallel ..... | 2848 |
| 52.5.5 | Two LVDS panels in parallel ..... | 2849 |
| 52.6 | Display subsystem interrupts ..... | 2849 |
| 52.7 | Display subsystem registers ..... | 2850 |
| 53 | LCD-TFT display controller (LTDC) ..... | 2851 |
| 53.1 | LTDC introduction ..... | 2851 |
| 53.2 | LTDC main features ..... | 2851 |
| 53.3 | LTDC implementation ..... | 2851 |
| 53.4 | LTDC functional description ..... | 2852 |
| 53.4.1 | LTDC block diagram ..... | 2852 |
| 53.4.2 | LTDC pins and internal signals ..... | 2853 |
| 53.4.3 | LTDC reset and clocks ..... | 2853 |
| 53.5 | LTDC configuration parameters ..... | 2856 |
| 53.5.1 | AXI master ..... | 2856 |
| 53.5.2 | Input layer definition and cropping ..... | 2856 |
| 53.5.3 | Input pixel format ..... | 2857 |
| 53.5.4 | YUV planar ..... | 2860 |
| 53.5.5 | YUV-to-RGB color conversion ..... | 2860 |
| 53.5.6 | Horizontal or vertical mirroring ..... | 2862 |
| 53.5.7 | Default layer color ..... | 2863 |
| 53.5.8 | Color look-up table (CLUT) ..... | 2863 |
| 53.5.9 | Transparency color keying ..... | 2864 |
| 53.5.10 | Upscaler ..... | 2864 |
| 53.5.11 | Display composition - windowing ..... | 2865 |
| 53.5.12 | Display composition - blending ..... | 2866 |
| 53.5.13 | Rotation ..... | 2868 |
| 53.5.14 | Gamma correction ..... | 2870 |
| 53.5.15 | YUV output conversion ..... | 2870 |
| 53.5.16 | Dithering ..... | 2871 |
| 53.5.17 | CRC hashing ..... | 2871 |
| 53.5.18 | Display timing ..... | 2872 |
| 53.5.19 | Output interface polarity ..... | 2874 |
| 53.5.20 | Shadow registers ..... | 2874 |
| 53.5.21 | General control ..... | 2876 |
| 53.5.22 | Provision for a secure layer ..... | 2876 |
| 53.6 | LTDC interrupts ..... | 2877 |
| 53.7 | LTDC programming procedure ..... | 2878 |
| 53.8 | LTDC registers ..... | 2879 |
| 53.8.1 | LTDC identification register (LTDC_IDR) ..... | 2879 |
| 53.8.2 | LTDC layer count register (LTDC_LCR) ..... | 2879 |
| 53.8.3 | LTDC synchronization size configuration register (LTDC_SSCR) ..... | 2880 |
| 53.8.4 | LTDC back porch configuration register (LTDC_BPCR) ..... | 2880 |
| 53.8.5 | LTDC active width configuration register (LTDC_AWCR) ..... | 2881 |
| 53.8.6 | LTDC total width configuration register (LTDC_TWCR) ..... | 2881 |
| 53.8.7 | LTDC global control register (LTDC_GCR) ..... | 2882 |
| 53.8.8 | LTDC global configuration 1 register (LTDC_GC1R) ..... | 2884 |
| 53.8.9 | LTDC global configuration 2 register (LTDC_GC2R) ..... | 2885 |
| 53.8.10 | LTDC shadow reload configuration register (LTDC_SRCR) ..... | 2886 |
| 53.8.11 | LTDC gamma correction configuration register (LTDC_GCCR) . . . . | 2886 |
| 53.8.12 | LTDC background color configuration register (LTDC_BCCR) . . . . . | 2887 |
| 53.8.13 | LTDC interrupt enable register (LTDC_IER) . . . . . | 2887 |
| 53.8.14 | LTDC interrupt status register (LTDC_ISR) . . . . . | 2888 |
| 53.8.15 | LTDC interrupt clear register (LTDC_ICR) . . . . . | 2889 |
| 53.8.16 | LTDC line interrupt position configuration register (LTDC_LIPCR) . . | 2890 |
| 53.8.17 | LTDC current position status register (LTDC_CPSR) . . . . . | 2891 |
| 53.8.18 | LTDC current display status register (LTDC_CDSR) . . . . . | 2891 |
| 53.8.19 | LTDC external display control register (LTDC_EDCR) . . . . . | 2892 |
| 53.8.20 | LTDC interrupt enable register 2 (LTDC_IER2) . . . . . | 2892 |
| 53.8.21 | LTDC interrupt status register 2 (LTDC_ISR2) . . . . . | 2893 |
| 53.8.22 | LTDC interrupt clear register 2 (LTDC_ICR2) . . . . . | 2894 |
| 53.8.23 | LTDC line interrupt position configuration register 2 (LTDC_LIPCR2) | 2895 |
| 53.8.24 | LTDC expected CRC register (LTDC_ECRCR) . . . . . | 2895 |
| 53.8.25 | LTDC computed CRC register (LTDC_CCRCR) . . . . . | 2896 |
| 53.8.26 | LTDC rotation buffer 0 address register (LTDC_RB0AR) . . . . . | 2896 |
| 53.8.27 | LTDC rotation buffer 1 address register (LTDC_RB1AR) . . . . . | 2897 |
| 53.8.28 | LTDC rotation buffer pitch register (LTDC_RBPR) . . . . . | 2897 |
| 53.8.29 | LTDC rotation intermediate frame color register (LTDC_RIFCR) . . . | 2898 |
| 53.8.30 | LTDC FIFO underrun threshold register (LTDC_FUTR) . . . . . | 2898 |
| 53.8.31 | LTDC layer x configuration 0 register (LTDC_LxC0R) . . . . . | 2899 |
| 53.8.32 | LTDC layer x configuration 1 register (LTDC_LxC1R) . . . . . | 2900 |
| 53.8.33 | LTDC layer x reload control register (LTDC_LxRCR) . . . . . | 2900 |
| 53.8.34 | LTDC layer x control register (LTDC_LxCR) . . . . . | 2901 |
| 53.8.35 | LTDC layer x window horizontal position configuration register (LTDC_LxWHPCR) . . . . . | 2902 |
| 53.8.36 | LTDC layer x window vertical position configuration register (LTDC_LxWVPCR) . . . . . | 2903 |
| 53.8.37 | LTDC layer x color keying configuration register (LTDC_LxCKCR) . . . . . | 2903 |
| 53.8.38 | LTDC layer x pixel format configuration register (LTDC_LxPFCR) . . . . . | 2904 |
| 53.8.39 | LTDC layer x constant alpha configuration register (LTDC_LxCACR) . . . . . | 2904 |
| 53.8.40 | LTDC layer x default color configuration register (LTDC_LxDCCR) . . . . . | 2905 |
| 53.8.41 | LTDC layer x blending factors configuration register (LTDC_LxBFCR) . . . . . | 2905 |
| 53.8.42 | LTDC layer x burst length configuration register (LTDC_LxBLCR) ..... | 2906 |
| 53.8.43 | LTDC layer x planar configuration register (LTDC_LxPCR) ..... | 2907 |
| 53.8.44 | LTDC layer x color frame buffer address register (LTDC_LxCFBAR) ..... | 2908 |
| 53.8.45 | LTDC layer x color frame buffer length register (LTDC_LxCFBLR) ..... | 2908 |
| 53.8.46 | LTDC layer x color frame buffer line number register (LTDC_LxCFBLNR) ..... | 2909 |
| 53.8.47 | LTDC layer x auxiliary frame buffer address 0 register (LTDC_LxAFBA0R) ..... | 2909 |
| 53.8.48 | LTDC layer x auxiliary frame buffer address 1 register (LTDC_LxAFBA1R) ..... | 2910 |
| 53.8.49 | LTDC layer x auxiliary frame buffer length register (LTDC_LxAFBLR) ..... | 2910 |
| 53.8.50 | LTDC layer x auxiliary frame buffer line number register (LTDC_LxAFBLNR) ..... | 2911 |
| 53.8.51 | LTDC layer x CLUT write register (LTDC_LxCLUTWR) ..... | 2911 |
| 53.8.52 | LTDC layer x scaler input size register (LTDC_LxSISR) ..... | 2912 |
| 53.8.53 | LTDC layer x scaler output size register (LTDC_LxSOSR) ..... | 2912 |
| 53.8.54 | LTDC layer x scaler vertical scaling factor register (LTDC_LxSVSFR) ..... | 2913 |
| 53.8.55 | LTDC layer x scaler vertical scaling phase register (LTDC_LxSVSPR) ..... | 2913 |
| 53.8.56 | LTDC layer x scaler horizontal scaling factor register (LTDC_LxSHSFR) ..... | 2914 |
| 53.8.57 | LTDC layer x scaler horizontal scaling phase register (LTDC_LxSHSPR) ..... | 2914 |
| 53.8.58 | LTDC layer x conversion YCbCr RGB 0 register (LTDC_LxCYR0R) .. | 2914 |
| 53.8.59 | LTDC layer x conversion YCbCr RGB 1 register (LTDC_LxCYR1R) .. | 2915 |
| 53.8.60 | LTDC layer x flexible pixel format 0 register (LTDC_LxFPF0R) .... | 2915 |
| 53.8.61 | LTDC layer x flexible pixel format 1 register (LTDC_LxFPF1R) .... | 2916 |
| 53.8.62 | LTDC register map ..... | 2916 |
| 54 | LVDS display interface transmitter (LVDS) ..... | 2924 |
| 54.1 | Introduction ..... | 2924 |
| 54.2 | LVDS main features ..... | 2924 |
| 54.3 | LVDS implementation ..... | 2924 |
| 54.4 | LVDS functional description ..... | 2925 |
| 54.4.1 | LVDS host block diagram | 2925 |
| 54.4.2 | LVDS pins and internal signals | 2925 |
| 54.4.3 | LVDS reset and clocks | 2925 |
| 54.4.4 | LVDS host input polarity functional block | 2925 |
| 54.4.5 | LVDS host data mapping functional block | 2926 |
| 54.4.6 | LVDS host link phase functional block | 2929 |
| 54.4.7 | LVDS host channel distribution | 2930 |
| 54.4.8 | LVDS host lane polarity functional block | 2931 |
| 54.4.9 | LVDS host PRBS Generator functional block | 2931 |
| 54.4.10 | LVDS PHY functional block | 2932 |
| 54.4.11 | LVDS Wrapper functional block | 2932 |
| 54.5 | LVDS host registers | 2933 |
| 54.5.1 | LVDS configuration register (LVDS_CR) | 2933 |
| 54.5.2 | LVDS data mapping LSB configuration register 0 (LVDS_DMLCR0) | 2934 |
| 54.5.3 | LVDS data mapping MSB configuration register 0 (LVDS_DMMCR0) | 2935 |
| 54.5.4 | LVDS data mapping LSB configuration register 1 (LVDS_DMLCR1) | 2935 |
| 54.5.5 | LVDS data mapping MSB configuration register 1 (LVDS_DMMCR1) | 2936 |
| 54.5.6 | LVDS data mapping LSB configuration register 2 (LVDS_DMLCR2) | 2937 |
| 54.5.7 | LVDS data mapping MSB configuration register 2 (LVDS_DMMCR2) | 2937 |
| 54.5.8 | LVDS data mapping LSB configuration register 3 (LVDS_DMLCR3) | 2938 |
| 54.5.9 | LVDS data mapping MSB configuration register 3 (LVDS_DMMCR3) | 2939 |
| 54.5.10 | LVDS data mapping LSB configuration register 4 (LVDS_DMLCR4) | 2939 |
| 54.5.11 | LVDS data mapping MSB configuration register 4 (LVDS_DMMCR4) | 2940 |
| 54.5.12 | LVDS channel distribution link 1 configuration register (LVDS_CDL1CR) | 2941 |
| 54.5.13 | LVDS channel distribution link 2 configuration register (LVDS_CDL2CR) | 2942 |
| 54.6 | LVDS PHY and LVDS Wrapper register | 2943 |
| 54.6.1 | LVDS PHY-Master global control register (LVDS_PMGCR) | 2943 |
| 54.6.2 | LVDS PHY-Master pre-emphasis amplitude control register (LVDS_PMPEACR) | 2944 |
| 54.6.3 | LVDS PHY-Master pre-emphasis time control register (LVDS_PMPETCR) | 2944 |
| 54.6.4 | LVDS PHY-Master current mode control register 1 (LVDS_PMCMCR1) ..... | 2945 |
| 54.6.5 | LVDS PHY-Master current mode control register 2 (LVDS_PMCMCR2) ..... | 2946 |
| 54.6.6 | LVDS PHY-Master Rx loopback control register (LVDS_PMRLPCR) ..... | 2947 |
| 54.6.7 | LVDS PHY-master Rx loopback status register (LVDS_PMRLPSR) ..... | 2948 |
| 54.6.8 | LVDS PHY-Master flipedge control register (LVDS_PMFCR) ..... | 2949 |
| 54.6.9 | LVDS PHY-Master serial control register (LVDS_PMSCR) ..... | 2950 |
| 54.6.10 | LVDS PHY-Master spare control register 1 (LVDS_PMSCR1) ..... | 2950 |
| 54.6.11 | LVDS PHY-Master spare control register 2 (LVDS_PMSCR2) ..... | 2951 |
| 54.6.12 | LVDS PHY-Master bias control register 1 (LVDS_PMBCR1) ..... | 2951 |
| 54.6.13 | LVDS PHY-Master bias control register 2 (LVDS_PMBCR2) ..... | 2952 |
| 54.6.14 | LVDS PHY-Master bias control register 3 (LVDS_PMBCR3) ..... | 2953 |
| 54.6.15 | LVDS PHY-Master bias control register 4 (LVDS_PMBCR4) ..... | 2955 |
| 54.6.16 | LVDS PHY-Master bias control register 5 (LVDS_PMBCR5) ..... | 2955 |
| 54.6.17 | LVDS PHY-Master impedance control register (LVDS_PMICR) ..... | 2956 |
| 54.6.18 | LVDS PHY-Master monitor bandgap current control register (LVDS_PMMBCCR) ..... | 2956 |
| 54.6.19 | LVDS PHY-Master monitor bandgap current status register (LVDS_PMMBCSR) ..... | 2957 |
| 54.6.20 | LVDS PHY-Master monitor bandgap loop control register (LVDS_PMMBLCR) ..... | 2958 |
| 54.6.21 | LVDS PHY-Master monitor bandgap loop status register (LVDS_PMMBLSR) ..... | 2958 |
| 54.6.22 | LVDS PHY-Master monitor bandgap output voltage control register (LVDS_PMMBOVCR) ..... | 2959 |
| 54.6.23 | LVDS PHY-Master monitor bandgap output voltage status register (LVDS_PMMBOVSR) ..... | 2960 |
| 54.6.24 | LVDS PHY-Master monitor PLL LDO output voltage control register (LVDS_PMMPLOVCR) ..... | 2960 |
| 54.6.25 | LVDS PHY-Master monitor PLL LDO output voltage status register (LVDS_PMMPLOVSR) ..... | 2961 |
| 54.6.26 | LVDS PHY-Master monitor PLL lock control register (LVDS_PMMPLCR) ..... | 2962 |
| 54.6.27 | LVDS PHY-Master monitor PLL lock status register (LVDS_PMMPLSR) ..... | 2962 |
| 54.6.28 | LVDS PHY-Master monitor PLL reference OK control register (LVDS_PMMPROCR) ..... | 2963 |
| 54.6.29 | LVDS PHY-Master monitor PLL reference OK status register (LVDS_PMMPROSR) ..... | 2964 |
| 54.6.30 | LVDS PHY-Master monitor serializer clock control register (LVDS_PMMSCCR) ..... | 2964 |
| 54.6.31 | LVDS PHY-Master monitor serializer clock status register (LVDS_PMMSCSR) ..... | 2965 |
| 54.6.32 | LVDS PHY-Master monitor serializer control register (LVDS_PMMSCR) ..... | 2965 |
| 54.6.33 | LVDS PHY-Master monitor serializer status register (LVDS_PMMSSR) ..... | 2966 |
| 54.6.34 | LVDS PHY-Master debug control register (LVDS_PMDCR) ..... | 2966 |
| 54.6.35 | LVDS PHY-Master spare status register 1 (LVDS_PMSSR1) ..... | 2967 |
| 54.6.36 | LVDS PHY-Master spare status register 2 (LVDS_PMSSR2) ..... | 2967 |
| 54.6.37 | LVDS PHY-Master configuration control register (LVDS_PMCFGCR) ..... | 2967 |
| 54.6.38 | LVDS PHY-Master PLL_MODE 1 control register (LVDS_PMPLLCR1) ..... | 2968 |
| 54.6.39 | LVDS PHY-Master PLL_MODE 2 control register (LVDS_PMPLLCR2) ..... | 2969 |
| 54.6.40 | LVDS PHY-Master PLL status register (LVDS_PMPLLSR) ..... | 2969 |
| 54.6.41 | LVDS PHY-Master PLL_SD_1 control register (LVDS_PMPLLSDCR1) ..... | 2970 |
| 54.6.42 | LVDS PHY-Master PLL_SD_2 control register (LVDS_PMPLLSDCR2) ..... | 2970 |
| 54.6.43 | LVDS PHY-Master PLL_TWG_1 control register (LVDS_PMPLLTWGCR1) ..... | 2971 |
| 54.6.44 | LVDS PHY-Master PLL_TWG_2 control register (LVDS_PMPLLTWGCR2) ..... | 2971 |
| 54.6.45 | LVDS PHY-Master PLL_LDO control register (LVDS_PMPLLLDOCR) ..... | 2971 |
| 54.6.46 | LVDS PHY-Master PLL_CP control register (LVDS_PMPLLCPCR) ..... | 2972 |
| 54.6.47 | LVDS PHY-Master PLL_CFG control register (LVDS_PMPLLCFGCR) ..... | 2972 |
| 54.6.48 | LVDS PHY-Master PLL_TEST control register (LVDS_PMPLLTESTCR) ..... | 2973 |
| 54.6.49 | LVDS PHY-Slave global control register (LVDS_PSGCR) ..... | 2973 |
| 54.6.50 | LVDS PHY-Slave pre-emphasis amplitude control register (LVDS_PSPEACR) ..... | 2974 |
| 54.6.51 | LVDS PHY-Slave pre-emphasis time control register (LVDS_PSPETCR) ..... | 2975 |
| 54.6.52 | LVDS PHY-Slave current mode control register 1 (LVDS_PSCMCR1) ..... | 2976 |
| 54.6.53 | LVDS PHY-Slave current mode control register 2 (LVDS_PSCMCR2) ..... | 2977 |
| 54.6.54 | LVDS PHY-Slave Rx loopback control register (LVDS_PSRLPCR) . | 2977 |
| 54.6.55 | LVDS PHY-slave Rx loopback status register (LVDS_PSRLPSR) ..... | 2979 |
| 54.6.56 | LVDS PHY-Slave flipedge control register (LVDS_PSFCR) ..... | 2980 |
| 54.6.57 | LVDS PHY-Slave serial control register (LVDS_PSSCR) ..... | 2981 |
| 54.6.58 | LVDS PHY-Slave spare control register 1 (LVDS_PSSCR1) ..... | 2981 |
| 54.6.59 | LVDS PHY-Slave spare control register 2 (LVDS_PSSCR2) ..... | 2982 |
| 54.6.60 | LVDS PHY-Slave bias control register 1 (LVDS_PSBCR1) ..... | 2982 |
| 54.6.61 | LVDS PHY-Slave bias control register 2 (LVDS_PSBCR2) ..... | 2983 |
| 54.6.62 | LVDS PHY-Slave bias control register 3 (LVDS_PSBCR3) ..... | 2984 |
| 54.6.63 | LVDS PHY-Slave bias control register 4 (LVDS_PSBCR4) ..... | 2986 |
| 54.6.64 | LVDS PHY-Slave bias control register 5 (LVDS_PSBCR5) ..... | 2986 |
| 54.6.65 | LVDS PHY-Slave impedance control register (LVDS_PSICR) ..... | 2987 |
| 54.6.66 | LVDS PHY-Slave monitor bandgap current control register (LVDS_PSMBCCR) ..... | 2988 |
| 54.6.67 | LVDS PHY-Slave monitor bandgap current status register (LVDS_PSMBCSR) ..... | 2988 |
| 54.6.68 | LVDS PHY-Slave monitor bandgap loop control register (LVDS_PSMBLCR) ..... | 2989 |
| 54.6.69 | LVDS PHY-Slave monitor bandgap loop status register (LVDS_PSMBLSR) ..... | 2990 |
| 54.6.70 | LVDS PHY-Slave monitor bandgap output voltage control register (LVDS_PSMBOVCR) ..... | 2990 |
| 54.6.71 | LVDS PHY-Slave monitor bandgap output voltage status register (LVDS_PSMBOVSR) ..... | 2991 |
| 54.6.72 | LVDS PHY-Slave monitor serializer clock control register (LVDS_PSMSCCR) ..... | 2992 |
| 54.6.73 | LVDS PHY-Slave monitor serializer clock status register (LVDS_PSMSCSR) ..... | 2992 |
| 54.6.74 | LVDS PHY-Slave monitor serializer control register (LVDS_PSMSCR) ..... | 2993 |
| 54.6.75 | LVDS PHY-Slave monitor serializer status register (LVDS_PSMSSR) ..... | 2993 |
| 54.6.76 | LVDS PHY-Slave debug control register (LVDS_PSDCR) ..... | 2994 |
| 54.6.77 | LVDS PHY-Slave spare status register 1 (LVDS_PSSSR1) ..... | 2994 |
| 54.6.78 | LVDS PHY-Slave spare status register 2 (LVDS_PSSSR2) ..... | 2995 |
| 54.6.79 | LVDS PHY-Slave configuration control register (LVDS_PSCFGCR) . | 2995 |
| 54.6.80 | LVDS wrapper clock control register (LVDS_WCLKCR) ..... | 2995 |
| 54.6.81 | LVDS PHY-Slave PLL_MODE 1 control register (LVDS_PSPLLCR1) ..... | 2996 |
| 54.6.82 | LVDS PHY-Slave PLL_MODE 2 control register (LVDS_PSPLLCR2) ..... | 2997 |
| 54.6.83 | LVDS PHY-Slave PLL status register (LVDS_PSPLLSR) ..... | 2997 |
| 54.6.84 | LVDS PHY-Slave PLL_SD_1 control register (LVDS_PSPLLSDCR1) ..... | 2998 |
| 54.6.85 | LVDS PHY-Slave PLL_SD_2 control register (LVDS_PSPLLSDCR2) ..... | 2998 |
| 54.6.86 | LVDS PHY-Slave PLL_TWG_1 control register (LVDS_PSPLLTWGCR1) ..... | 2999 |
| 54.6.87 | LVDS PHY-Slave PLL_TWG_2 control register (LVDS_PSPLLTWGCR2) ..... | 2999 |
| 54.6.88 | LVDS PHY-Slave PLL_LDO control register (LVDS_PSPLLLDOCR) ..... | 3000 |
| 54.6.89 | LVDS PHY-Slave PLL_CP control register (LVDS_PSPLLCPCR) .. | 3000 |
| 54.6.90 | LVDS PHY-Slave PLL_CFG control register (LVDS_PSPLLCFGR) .. | 3001 |
| 54.6.91 | LVDS PHY-Slave PLL_TEST control register (LVDS_PSPLLTESTCR) ..... | 3001 |
| 54.6.92 | LVDS PHY-Master analog test control register 1 (LVDS_PMATCR1) ..... | 3002 |
| 54.6.93 | LVDS PHY-Master analog test control register 2 (LVDS_PMATCR2) ..... | 3003 |
| 54.6.94 | LVDS PHY-Master digital test control register 1 (LVDS_PMDTCR1) ..... | 3004 |
| 54.6.95 | LVDS PHY-Master digital test control register 2 (LVDS_PMDTCR2) ..... | 3005 |
| 54.6.96 | LVDS PHY-Master digital test status register (LVDS_PMDTSR) .... | 3006 |
| 54.6.97 | LVDS PHY-Slave analog test control register 1 (LVDS_PSATCR1) .. | 3006 |
| 54.6.98 | LVDS PHY-Slave analog test control register 2 (LVDS_PSATCR2) .. | 3008 |
| 54.6.99 | LVDS PHY-Slave digital test control register 1 (LVDS_PSDTCR1) .. | 3009 |
| 54.6.100 | LVDS PHY-Slave digital test control register 2 (LVDS_PSDTCR2) .. | 3010 |
| 54.6.101 | LVDS PHY-Slave digital test status register (LVDS_PSDTSR) .... | 3011 |
| 54.6.102 | LVDS hardware configuration register (LVDS_HWCFGR) ..... | 3011 |
| 54.6.103 | LVDS version register (LVDS_VERR) ..... | 3012 |
| 54.6.104 | LVDS identification register (LVDS_IPIDR) ..... | 3012 |
| 54.6.105 | LVDS size register (LVDS_SIDR) ..... | 3012 |
| 54.6.106 | LVDS register map ..... | 3013 |
| 55 | DSI Host (DSI) ..... | 3032 |
| 55.1 | Introduction ..... | 3032 |
| 55.2 | Standard and references ..... | 3032 |
| 55.3 | DSI Host main features ..... | 3032 |
| 55.4 | DSI Host functional description ..... | 3033 |
| 55.4.1 | General description ..... | 3033 |
| 55.4.2 | DSI pins and internal signals ..... | 3034 |
| 55.4.3 | Supported resolutions and frame rates ..... | 3035 |
| 55.4.4 | System level architecture ..... | 3035 |
| 55.5 | Functional description: video mode on LTDC interface ..... | 3036 |
| 55.5.1 | Video transmission mode ..... | 3038 |
| 55.5.2 | Updating the LTDC interface configuration in video mode ..... | 3040 |
| 55.6 | Functional description: adapted command mode on LTDC interface .. | 3041 |
| 55.7 | Functional description: APB slave generic interface ..... | 3045 |
| 55.7.1 | Packet transmission using the generic interface ..... | 3046 |
| 55.8 | Functional description: timeout counters ..... | 3049 |
| 55.8.1 | Contention error detection timeout counters ..... | 3049 |
| 55.8.2 | Peripheral response timeout counters ..... | 3050 |
| 55.9 | Functional description: transmission of commands ..... | 3055 |
| 55.9.1 | Transmission of commands in video mode ..... | 3055 |
| 55.9.2 | Transmission of commands in low-power mode ..... | 3057 |
| 55.9.3 | Transmission of commands in high-speed ..... | 3061 |
| 55.9.4 | Read command transmission ..... | 3062 |
| 55.9.5 | Clock lane in low-power mode ..... | 3062 |
| 55.10 | Functional description: virtual channels ..... | 3064 |
| 55.11 | Functional description: video mode pattern generator ..... | 3065 |
| 55.11.1 | Color bar pattern ..... | 3065 |
| 55.11.2 | Color coding ..... | 3067 |
| 55.11.3 | BER testing pattern ..... | 3067 |
| 55.11.4 | Video mode pattern generator resolution ..... | 3068 |
| 55.12 | Functional description: D-PHY management ..... | 3069 |
| 55.12.1 | D-PHY configuration ..... | 3069 |
| 55.12.2 | Special D-PHY operations ..... | 3069 |
| 55.12.3 | Special low-power D-PHY functions ..... | 3069 |
| 55.12.4 | DSI PLL control ..... | 3069 |
| 55.13 | Functional description: interrupts and errors ..... | 3074 |
| 55.13.1 | DSI Wrapper interrupts ..... | 3074 |
| 55.13.2 | DSI Host interrupts and errors ..... | 3074 |
| 55.14 | Programing procedure | 3081 |
| 55.14.1 | Programing procedure overview | 3081 |
| 55.14.2 | Configuring the D-PHY parameters | 3082 |
| 55.14.3 | Configuring the DSI Host timing | 3082 |
| 55.14.4 | Configuring flow control and DBI interface | 3083 |
| 55.14.5 | Configuring the DSI Host LTDC interface | 3083 |
| 55.14.6 | Configuring the video mode | 3084 |
| 55.14.7 | Configuring the adapted command mode | 3088 |
| 55.14.8 | Configuring the video mode pattern generator | 3088 |
| 55.14.9 | Managing ULPM | 3089 |
| 55.15 | DSI Host registers | 3091 |
| 55.15.1 | DSI Host version register (DSI_VR) | 3091 |
| 55.15.2 | DSI Host control register (DSI_CR) | 3091 |
| 55.15.3 | DSI Host clock control register (DSI_CCR) | 3092 |
| 55.15.4 | DSI Host LTDC VCID register (DSI_LVCIDR) | 3092 |
| 55.15.5 | DSI Host LTDC color coding register (DSI_LCOLCR) | 3092 |
| 55.15.6 | DSI Host LTDC polarity configuration register (DSI_LPCR) | 3093 |
| 55.15.7 | DSI Host low-power mode configuration register (DSI_LPMCR) | 3094 |
| 55.15.8 | DSI Host protocol configuration register (DSI_PCR) | 3094 |
| 55.15.9 | DSI Host generic VCID register (DSI_GVCIDR) | 3095 |
| 55.15.10 | DSI Host mode configuration register (DSI_MCR) | 3095 |
| 55.15.11 | DSI Host video mode configuration register (DSI_VMCR) | 3096 |
| 55.15.12 | DSI Host video packet configuration register (DSI_VPCR) | 3097 |
| 55.15.13 | DSI Host video chunks configuration register (DSI_VCCR) | 3098 |
| 55.15.14 | DSI Host video null packet configuration register (DSI_VNPCR) | 3098 |
| 55.15.15 | DSI Host video HSA configuration register (DSI_VHSACR) | 3098 |
| 55.15.16 | DSI Host video HBP configuration register (DSI_VHBPCR) | 3099 |
| 55.15.17 | DSI Host video line configuration register (DSI_VLCR) | 3099 |
| 55.15.18 | DSI Host video VSA configuration register (DSI_VVSACR) | 3099 |
| 55.15.19 | DSI Host video VBP configuration register (DSI_VVBPCR) | 3100 |
| 55.15.20 | DSI Host video VFP configuration register (DSI_VVFPCR) | 3100 |
| 55.15.21 | DSI Host video VA configuration register (DSI_VVACR) | 3101 |
| 55.15.22 | DSI Host LTDC command configuration register (DSI_LCCR) | 3101 |
| 55.15.23 | DSI Host command mode configuration register (DSI_CMCR) | 3101 |
| 55.15.24 | DSI Host generic header configuration register (DSI_GHCR) | 3103 |
| 55.15.25 | DSI Host generic payload data register (DSI_GPDR) | 3104 |
| 55.15.26 | DSI Host generic packet status register (DSI_GPSR) | 3104 |
| 55.15.27 DSI Host timeout counter configuration register 0 (DSI_TCCR0) . . . | 3105 |
| 55.15.28 DSI Host timeout counter configuration register 1 (DSI_TCCR1) . . . | 3106 |
| 55.15.29 DSI Host timeout counter configuration register 2 (DSI_TCCR2) . . . | 3106 |
| 55.15.30 DSI Host timeout counter configuration register 3 (DSI_TCCR3) . . . | 3106 |
| 55.15.31 DSI Host timeout counter configuration register 4 (DSI_TCCR4) . . . | 3107 |
| 55.15.32 DSI Host timeout counter configuration register 5 (DSI_TCCR5) . . . | 3108 |
| 55.15.33 DSI Host 3D configuration register (DSI_TDCR) . . . . . | 3108 |
| 55.15.34 DSI Host clock lane configuration register (DSI_CLCR) . . . . . | 3109 |
| 55.15.35 DSI Host clock lane timer configuration register (DSI_CLTCR) . . . . . | 3109 |
| 55.15.36 DSI Host data lane timer configuration register (DSI_DLTCR) . . . . . | 3110 |
| 55.15.37 DSI Host PHY control register (DSI_PCTLR) . . . . . | 3110 |
| 55.15.38 DSI Host PHY configuration register (DSI_PCONFR) . . . . . | 3111 |
| 55.15.39 DSI Host PHY ULPS control register (DSI_PUCR) . . . . . | 3111 |
| 55.15.40 DSI Host PHY TX triggers configuration register (DSI_PTTCR) . . . . . | 3112 |
| 55.15.41 DSI Host PHY status register (DSI_PSR) . . . . . | 3112 |
| 55.15.42 DSI Host PHY test control register 0 (DSI_PTCR0) . . . . . | 3113 |
| 55.15.43 DSI Host PHY test control register 1 (DSI_PTCR1) . . . . . | 3114 |
| 55.15.44 DSI Host interrupt and status register 0 (DSI_ISR0) . . . . . | 3114 |
| 55.15.45 DSI Host interrupt and status register 1 (DSI_ISR1) . . . . . | 3116 |
| 55.15.46 DSI Host interrupt enable register 0 (DSI_IER0) . . . . . | 3117 |
| 55.15.47 DSI Host interrupt enable register 1 (DSI_IER1) . . . . . | 3120 |
| 55.15.48 DSI Host PHY calibration control register (DSI_PCCR) . . . . . | 3122 |
| 55.15.49 DSI Host force interrupt register 0 (DSI_FIR0) . . . . . | 3122 |
| 55.15.50 DSI Host force interrupt register 1 (DSI_FIR1) . . . . . | 3124 |
| 55.15.51 DSI Host data lane timer read configuration register (DSI_DLTRCR) . . . . . | 3125 |
| 55.15.52 DSI Host video shadow control register (DSI_VSCR) . . . . . | 3125 |
| 55.15.53 DSI Host LTDC current VCID register (DSI_LCVCIDR) . . . . . | 3126 |
| 55.15.54 DSI Host LTDC current color coding register (DSI_LCCCR) . . . . . | 3126 |
| 55.15.55 DSI Host low-power mode current configuration register (DSI_LPMCCR) . . . . . | 3127 |
| 55.15.56 DSI Host video mode current configuration register (DSI_VMCCR) . . . . . | 3127 |
| 55.15.57 DSI Host video packet current configuration register (DSI_VPCCR) . . . . . | 3128 |
| 55.15.58 DSI Host video chunks current configuration register (DSI_VCCCR) . . . . . | 3129 |
| 55.15.59 DSI Host video null packet current configuration register (DSI_VNPCCR) . . . . . | 3129 |
| 55.15.60 | DSI Host video HSA current configuration register (DSI_VHSACCR) | 3129 |
| 55.15.61 | DSI Host video HBP current configuration register (DSI_VHBPCR) | 3130 |
| 55.15.62 | DSI Host video line current configuration register (DSI_VLCCR) | 3130 |
| 55.15.63 | DSI Host video VSA current configuration register (DSI_VVSACCR) | 3131 |
| 55.15.64 | DSI Host video VBP current configuration register (DSI_VVBPCR) | 3131 |
| 55.15.65 | DSI Host video VFP current configuration register (DSI_VVFPCCR) | 3131 |
| 55.15.66 | DSI Host video VA current configuration register (DSI_VVACCR) | 3132 |
| 55.15.67 | DSI Host 3D current configuration register (DSI_TDCCR) | 3132 |
| 55.16 | DSI Wrapper registers | 3134 |
| 55.16.1 | DSI Wrapper configuration register (DSI_WCFGR) | 3134 |
| 55.16.2 | DSI Wrapper control register (DSI_WCR) | 3135 |
| 55.16.3 | DSI Wrapper interrupt enable register (DSI_WIER) | 3135 |
| 55.16.4 | DSI Wrapper interrupt and status register (DSI_WISR) | 3136 |
| 55.16.5 | DSI Wrapper interrupt flag clear register (DSI_WIFCR) | 3137 |
| 55.16.6 | DSI Wrapper PHY configuration register 0 (DSI_WPCR0) | 3138 |
| 55.16.7 | DSI Wrapper PHY configuration register 1 (DSI_WPCR1) | 3138 |
| 55.16.8 | DSI Wrapper regulator and PLL configuration register 0 (DSI_WRPCR0) | 3139 |
| 55.16.9 | DSI Wrapper regulator and PLL configuration register 1 (DSI_WRPCR1) | 3140 |
| 55.16.10 | DSI Wrapper regulator and PLL configuration register 2 (DSI_WRPCR2) | 3141 |
| 55.16.11 | DSI Wrapper regulator and PLL status register 0 (DSI_WRPSR0) | 3142 |
| 55.16.12 | DSI Wrapper regulator and PLL status register 1 (DSI_WRPSR1) | 3142 |
| 55.16.13 | DSI Wrapper control register bis (DSI_WCRB) | 3143 |
| 55.16.14 | DSI hardware configuration register (DSI_HWCFGR) | 3143 |
| 55.16.15 | DSI version register (DSI_VERR) | 3144 |
| 55.16.16 | DSI identification register (DSI_IPIDR) | 3144 |
| 55.16.17 | DSI size identification register (DSI_SIDR) | 3145 |
| 55.17 | DSI register map | 3146 |
| 56 | Video encoder (VENC) | 3152 |
| 56.1 | VENC introduction | 3152 |
| 56.2 | VENC main features . . . . . | 3152 |
| 56.3 | VENC implementation . . . . . | 3152 |
| 56.4 | VENC functional description . . . . . | 3153 |
| 56.4.1 | VENC block diagram . . . . . | 3153 |
| 56.4.2 | VENC pins and internal signals . . . . . | 3153 |
| 56.4.3 | VENC reset and clocks . . . . . | 3154 |
| 56.4.4 | VENC pre-processor . . . . . | 3154 |
| 56.4.5 | VENC H264/VP8 encoder . . . . . | 3154 |
| 56.4.6 | VENC JPEG encoder . . . . . | 3155 |
| 56.4.7 | VENC security . . . . . | 3155 |
| 56.4.8 | VENC power-on sequence . . . . . | 3156 |
| 56.4.9 | VENCRAM power-on sequence for AXI access . . . . . | 3156 |
| 56.5 | VENC low power modes . . . . . | 3157 |
| 56.6 | VENC interrupts . . . . . | 3157 |
| 56.7 | VENC registers . . . . . | 3157 |
| 56.7.1 | VENC ID register (VENC_SWREG0) . . . . . | 3157 |
| 56.7.2 | VENC interrupt register (VENC_SWREG1) . . . . . | 3157 |
| 56.7.3 | VENC bus interface configuration register (VENC_SWREG2) . . . . . | 3158 |
| 56.7.4 | VENC device configuration register (VENC_SWREG3) . . . . . | 3158 |
| 56.7.5 | VENC base address for output stream data register (VENC_SWREG5) . . . . . | 3158 |
| 56.7.6 | VENC base address for output control data register (VENC_SWREG6) . . . . . | 3159 |
| 56.7.7 | VENC base address for reference luma register (VENC_SWREG7) . . . . . | 3159 |
| 56.7.8 | VENC base address for reference chroma register (VENC_SWREG8) . . . . . | 3159 |
| 56.7.9 | VENC base address for reconstructed luma register (VENC_SWREG9) . . . . . | 3160 |
| 56.7.10 | VENC base address for reconstructed chroma register (VENC_SWREG10) . . . . . | 3160 |
| 56.7.11 | VENC base address for input picture luma register (VENC_SWREG11) . . . . . | 3160 |
| 56.7.12 | VENC base address for input picture cb register (VENC_SWREG12) . . . . . | 3161 |
| 56.7.13 | VENC base address for input picture cr register (VENC_SWREG13) . . . . . | 3161 |
| 56.7.14 | VENC encoder control register 0 (VENC_SWREG14) . . . . . | 3161 |
| 56.7.15 | VENC encoder control register 1 (VENC_SWREG15) . . . . . | 3162 |
| 56.7.16 | VENC encoder control register 2 (VENC_SWREG16) ..... | 3162 |
| 56.7.17 | VENC encoder control register 3 (VENC_SWREG17) ..... | 3162 |
| 56.7.18 | VENC encoder control register 4 (VENC_SWREG18) ..... | 3163 |
| 56.7.19 | VENC encoder control register 5 (VENC_SWREG19) ..... | 3163 |
| 56.7.20 | VENC encoder control register 6 (VENC_SWREG20) ..... | 3163 |
| 56.7.21 | VENC encoder control register 7 (VENC_SWREG21) ..... | 3164 |
| 56.7.22 | VENC stream header remainder MSB bits register (VENC_SWREG22) ..... | 3164 |
| 56.7.23 | VENC stream header remainder LSB bits register (VENC_SWREG23) ..... | 3164 |
| 56.7.24 | VENC stream buffer limit/output stream size register (VENC_SWREG24) ..... | 3165 |
| 56.7.25 | VENC encoder control register 8 (VENC_SWREG25) ..... | 3165 |
| 56.7.26 | VENC intra-slice bitmap/base address for VP8 counters register (VENC_SWREG26) ..... | 3165 |
| 56.7.27 | VENC encoder control register 9 (VENC_SWREG27) ..... | 3166 |
| 56.7.28 | VENC encoder control register 10 (VENC_SWREG28) ..... | 3166 |
| 56.7.29 | VENC encoder control register 11 (VENC_SWREG29) ..... | 3166 |
| 56.7.30 | VENC encoder control register 12 (VENC_SWREG30) ..... | 3167 |
| 56.7.31 | VENC encoder control register 13 (VENC_SWREG31) ..... | 3167 |
| 56.7.32 | VENC encoder control register 14 (VENC_SWREG32) ..... | 3167 |
| 56.7.33 | VENC encoder control register 15 (VENC_SWREG33) ..... | 3168 |
| 56.7.34 | VENC encoder control register 16 (VENC_SWREG34) ..... | 3168 |
| 56.7.35 | VENC H.264 checkpoint word error 5-6/encoder control register 17 (VENC_SWREG35) ..... | 3168 |
| 56.7.36 | VENC H.264 checkpoint delta QP 1-8/encoder control register 18 (VENC_SWREG36) ..... | 3169 |
| 56.7.37 | VENC encoder control register 19, VP8 filter, stream start offset (VENC_SWREG37) ..... | 3169 |
| 56.7.38 | VENC macroblock count output register (VENC_SWREG38) ..... | 3169 |
| 56.7.39 | VENC base address for next pic luminance register (VENC_SWREG39) ..... | 3170 |
| 56.7.40 | VENC stabilization mode control register (VENC_SWREG40) ..... | 3170 |
| 56.7.41 | VENC stabilization motion sum div8 output register (VENC_SWREG41) ..... | 3170 |
| 56.7.42 | VENC stabilization GMV output, matrix 1, up-left position output register (VENC_SWREG42) ..... | 3171 |
| 56.7.43 | VENC stabilization GMV output, matrix 2, up position output register (VENC_SWREG43) ..... | 3171 |
| 56.7.44 | VENC stabilization matrix 3, up-right position output register (VENC_SWREG44) ..... | 3171 |
| 56.7.45 | VENC stabilization matrix 4, left position output register (VENC_SWREG45) ..... | 3172 |
| 56.7.46 | VENC stabilization matrix 5, GMV position output register (VENC_SWREG46) ..... | 3172 |
| 56.7.47 | VENC stabilization matrix 6, right position output register (VENC_SWREG47) ..... | 3172 |
| 56.7.48 | VENC stabilization matrix 7, down-left position output register (VENC_SWREG48) ..... | 3173 |
| 56.7.49 | VENC stabilization matrix 8, down position output register (VENC_SWREG49) ..... | 3173 |
| 56.7.50 | VENC stabilization matrix 9, down-right position output register (VENC_SWREG50) ..... | 3173 |
| 56.7.51 | VENC base address for cabac context tables H264 or probability tables VP8 register (VENC_SWREG51) ..... | 3174 |
| 56.7.52 | VENC base address for MV output writing register (VENC_SWREG52) ..... | 3174 |
| 56.7.53 | VENC RGB to YUV conversion coefficient A - B register (VENC_SWREG53) ..... | 3174 |
| 56.7.54 | VENC RGB to YUV conversion coefficient C - E register (VENC_SWREG54) ..... | 3175 |
| 56.7.55 | VENC RGB to YUV conversion coefficient F, RGB mask MSB bit position register (VENC_SWREG55) ..... | 3175 |
| 56.7.56 | VENC intra area register (VENC_SWREG56) ..... | 3175 |
| 56.7.57 | VENC CIR intra mb position register (VENC_SWREG57) ..... | 3176 |
| 56.7.58 | VENC intra slice bitmap for slices 0..31/base address for VP8 1st DCT partition register (VENC_SWREG58) ..... | 3176 |
| 56.7.59 | VENC intra slice bitmap for slices 32..63/base address for VP8 2nd DCT partition register (VENC_SWREG59) ..... | 3176 |
| 56.7.60 | VENC 1st ROI area register (VENC_SWREG60) ..... | 3177 |
| 56.7.61 | VENC 2nd ROI area register (VENC_SWREG61) ..... | 3177 |
| 56.7.62 | VENC ROI area delta QP, MV register (VENC_SWREG62) ..... | 3177 |
| 56.7.63 | VENC synthesis configuration register encoder 0 register (VENC_SWREG63) ..... | 3178 |
| 56.7.64 | VENC JPEG luma quantization 1/VP8 intra 16x16 mode 0-1 penalty register (VENC_SWREG64) ..... | 3178 |
| 56.7.65 | VENC JPEG luma quantization 2/VP8 intra 16x16 mode 2-3 penalty register (VENC_SWREG65) ..... | 3178 |
| 56.7.66 | VENC JPEG luma quantization 3/VP8 intra 4x4 mode 0-1 penalty register (VENC_SWREG66) ..... | 3179 |
| 56.7.67 | VENC JPEG luma quantization 4/VP8 intra 4x4 mode 2-3 penalty register (VENC_SWREG67) ..... | 3179 |
| 56.7.68 | VENC JPEG luma quantization 5/VP8 intra 4x4 mode 4-5 penalty register (VENC_SWREG68) ..... | 3179 |
| 56.7.69 | VENC JPEG luma quantization 6/VP8 intra 4x4 mode 6-7 penalty register (VENC_SWREG69) ..... | 3180 |
| 56.7.70 | VENC JPEG luma quantization 7/VP8 intra 4x4 mode 8-9 penalty register (VENC_SWREG70) ..... | 3180 |
| 56.7.71 | VENC JPEG luma quantization 8/base address for VP8 segmentation map register (VENC_SWREG71) ..... | 3180 |
| 56.7.72 | VENC JPEG luma quantization 9/VP8 segment1 parameter register (VENC_SWREG72) ..... | 3181 |
| 56.7.73 | VENC JPEG luma quantization 10/VP8 segment1 parameter register (VENC_SWREG73) ..... | 3181 |
| 56.7.74 | VENC JPEG luma quantization 11/VP8 segment1 parameter register (VENC_SWREG74) ..... | 3181 |
| 56.7.75 | VENC JPEG luma quantization 12/VP8 segment1 parameter register (VENC_SWREG75) ..... | 3182 |
| 56.7.76 | VENC JPEG luma quantization 13/VP8 segment1 parameter register (VENC_SWREG76) ..... | 3182 |
| 56.7.77 | VENC JPEG luma quantization 14/VP8 segment1 parameter register (VENC_SWREG77) ..... | 3182 |
| 56.7.78 | VENC JPEG luma quantization 15/VP8 segment1 parameter register (VENC_SWREG78) ..... | 3183 |
| 56.7.79 | VENC JPEG luma quantization 16/VP8 segment2 parameter register (VENC_SWREG79) ..... | 3183 |
| 56.7.80 | VENC JPEG chroma quantization 1/VP8 segment2 parameter register (VENC_SWREG80) ..... | 3183 |
| 56.7.81 | VENC JPEG chroma quantization 2/VP8 segment2 parameter register (VENC_SWREG81) ..... | 3184 |
| 56.7.82 | VENC JPEG chroma quantization 3/VP8 segment2 parameter register (VENC_SWREG82) ..... | 3184 |
| 56.7.83 | VENC JPEG chroma quantization 4/VP8 segment2 parameter register (VENC_SWREG83) ..... | 3184 |
| 56.7.84 | VENC JPEG chroma quantization 5/VP8 segment2 parameter register (VENC_SWREG84) ..... | 3185 |
| 56.7.85 | VENC JPEG chroma quantization 6/VP8 segment2 parameter register (VENC_SWREG85) ..... | 3185 |
| 56.7.86 | VENC JPEG chroma quantization 7/VP8 segment2 parameter register (VENC_SWREG86) ..... | 3185 |
| 56.7.87 | VENC JPEG chroma quantization 8/VP8 segment2 parameter register (VENC_SWREG87) ..... | 3186 |
| 56.7.88 | VENC JPEG chroma quantization 9/VP8 segment3 parameter register (VENC_SWREG88) ..... | 3186 |
| 56.7.89 | VENC JPEG chroma quantization 10/VP8 segment3 parameter register (VENC_SWREG89) ..... | 3186 |
| 56.7.90 | VENC JPEG chroma quantization 11/VP8 segment3 parameter register (VENC_SWREG90) ..... | 3187 |
| 56.7.91 | VENC JPEG chroma quantization 12/VP8 segment3 parameter register (VENC_SWREG91) ..... | 3187 |
| 56.7.92 | VENC JPEG chroma quantization 13/VP8 segment3 parameter register (VENC_SWREG92) ..... | 3187 |
| 56.7.93 | VENC JPEG chroma quantization 14/VP8 segment3 parameter register (VENC_SWREG93) ..... | 3188 |
| 56.7.94 | VENC JPEG chroma quantization 15/VP8 segment3 parameter register (VENC_SWREG94) ..... | 3188 |
| 56.7.95 | VENC JPEG chroma quantization 16/VP8 segment3 parameter register (VENC_SWREG95) ..... | 3188 |
| 56.7.96 | VENC DMV 4p/1p penalty values 0-3 register (VENC_SWREG96) . | 3189 |
| 56.7.97 | VENC DMV 4p/1p penalty values 4-7 register (VENC_SWREG97) . | 3189 |
| 56.7.98 | VENC DMV 4p/1p penalty values register (VENC_SWREGx) .... | 3189 |
| 56.7.99 | VENC DMV 4p/1p penalty values 124-127 register (VENC_SWREG127) ..... | 3189 |
| 56.7.100 | VENC DMV qpel penalty values 0-3 register (VENC_SWREG128) ..... | 3190 |
| 56.7.101 | VENC DMV qpel penalty values 4-7 register (VENC_SWREG129) ..... | 3190 |
| 56.7.102 | VENC DMV qpel penalty values register (VENC_SWREGx) .... | 3191 |
| 56.7.103 | VENC DMV qpel penalty values 124-127 register (VENC_SWREG159) ..... | 3191 |
| 56.7.104 | VENC VP8 bit cost of inter type, coeff for dmv penalty register (VENC_SWREG160) ..... | 3191 |
| 56.7.105 | VENC VP8 bit cost of golden ref frame register (VENC_SWREG161) ..... | 3192 |
| 56.7.106 | VENC VP8 loop filter delta register (VENC_SWREGx) ..... | 3192 |
| 56.7.107 | VENC VP8 deadzone lookup table register (VENC_SWREGx) .... | 3192 |
| 56.7.108 | VENC VP8 deadzone rate multiplier for plane 0-1 register (VENC_SWREG228) ..... | 3193 |
| 56.7.109 | VENC VP8 deadzone rate multiplier for plane 2-3 register (VENC_SWREG229) ..... | 3193 |
| 56.7.110 | VENC VP8 deadzone rate for macroblock skip token 0-1 register (VENC_SWREG230) ..... | 3193 |
| 56.7.111 | VENC base address for output of down-scaled encoder image in YUYV 4:2:2 format register (VENC_SWREG231) ..... | 3194 |
| 56.7.112 | VENC scaling control register (VENC_SWREGx) ..... | 3194 |
| 56.7.113 | VENC squared error output calculated for 13x13 pixels per macroblock register (VENC_SWREG236) ..... | 3194 |
| 56.7.114 | VENC MAD 2 control and output register (VENC_SWREG237) .... | 3195 |
| 56.7.115 | VENC MAD 3 control and output register (VENC_SWREG238) . . . . | 3195 |
| 56.7.116 | VENC VP8 predictor interpolation coefficient for full pixel position register (VENC_SWREG239) . . . . . | 3195 |
| 56.7.117 | VENC VP8 predictor interpolation coefficient for 1/8 pixel position register (VENC_SWREG240) . . . . . | 3196 |
| 56.7.118 | VENC VP8 predictor interpolation coefficient for 2/8 pixel position register (VENC_SWREG241) . . . . . | 3196 |
| 56.7.119 | VENC VP8 predictor interpolation coefficient for 3/8 pixel position register (VENC_SWREG242) . . . . . | 3196 |
| 56.7.120 | VENC VP8 predictor interpolation coefficient for 4/8 pixel position register (VENC_SWREG243) . . . . . | 3197 |
| 56.7.121 | VENC base address for VP8 3rd DCT partition register (VENC_SWREG244) . . . . . | 3197 |
| 56.7.122 | VENC base address for VP8 4th DCT partition register (VENC_SWREG245) . . . . . | 3197 |
| 56.7.123 | VENC segment 1: intra 16x16 mode 0-2 penalty register (VENC_SWREG256) . . . . . | 3198 |
| 56.7.124 | VENC segment 1: intra 16x16 mode 3, intra 4x4 0-1 penalty register (VENC_SWREG257) . . . . . | 3198 |
| 56.7.125 | VENC segment 1: intra 4x4 mode 2-4 penalty register (VENC_SWREG258) . . . . . | 3198 |
| 56.7.126 | VENC segment 1: intra 4x4 mode 5-7 penalty register (VENC_SWREG259) . . . . . | 3199 |
| 56.7.127 | VENC segment 1: intra 4x4 mode 8-9 penalty, previous mode favor for H.264 register (VENC_SWREG260) . . . . . | 3199 |
| 56.7.128 | VENC segment 1: bit cost of inter type, intra 16x16 mode favor register (VENC_SWREG261) . . . . . | 3199 |
| 56.7.129 | VENC segment 1: inter MB mode favor, skip mode penalty, penalty value for 2nd reference frame register (VENC_SWREG262) | 3200 |
| 56.7.130 | VENC segment 1: penalty value register (VENC_SWREGx) . . . . . | 3200 |
| 56.7.131 | VENC segment 1: deadzone rate multiplier for plane 0-1 register (VENC_SWREG265) . . . . . | 3200 |
| 56.7.132 | VENC segment 1: deadzone rate multiplier for plane 2-3 register (VENC_SWREG266) . . . . . | 3201 |
| 56.7.133 | VENC segment 1: deadzone rate for macroblock skip token 0-1, dmv penalty coefficient register (VENC_SWREG267) . . . . . | 3201 |
| 56.7.134 | VENC segment 2: intra 16x16 mode 0-2 penalty register (VENC_SWREG268) . . . . . | 3201 |
| 56.7.135 | VENC segment 2: intra 16x16 mode 3 penalty, intra 4x4 mode 0-1 penalty register (VENC_SWREG269) . . . . . | 3202 |
| 56.7.136 | VENC segment 2: intra 4x4 mode 2-4 penalty register (VENC_SWREG270) . . . . . | 3202 |
| 56.7.137 VENC segment 2: intra 4x4 mode 5-7 penalty register (VENC_SWREG271) ..... | 3202 |
| 56.7.138 VENC segment 2: intra 4x4 mode 8-9 penalty, intra 4x4 previous mode favor for H.264 register (VENC_SWREG272) ..... | 3203 |
| 56.7.139 VENC segment 2: bit cost of inter type, intra 16x16 mode favor register (VENC_SWREG273) ..... | 3203 |
| 56.7.140 VENC segment 2: inter MB mode favor, skip mode penalty, penalty value register (VENC_SWREG274) ..... | 3203 |
| 56.7.141 VENC segment 2: penalty value register (VENC_SWREGx) ..... | 3204 |
| 56.7.142 VENC segment 2: deadzone rate multiplier for plane 0-1 register (VENC_SWREG277) ..... | 3204 |
| 56.7.143 VENC segment 2: deadzone rate multiplier for plane 2-3 register (VENC_SWREG278) ..... | 3204 |
| 56.7.144 VENC segment 2: deadzone rate for macroblock skip token 0-1, dmv penalty coefficient register (VENC_SWREG279) ..... | 3205 |
| 56.7.145 VENC segment 3: intra 16x16 mode 0-2 penalty register (VENC_SWREG280) ..... | 3205 |
| 56.7.146 VENC segment 3: intra 16x16 mode 3 penalty, intra 4x4 mode 0-1 penalty register (VENC_SWREG281) ..... | 3205 |
| 56.7.147 VENC segment 3: intra 4x4 mode 2-4 penalty register (VENC_SWREG282) ..... | 3206 |
| 56.7.148 VENC segment 3: intra 4x4 mode 5-7 penalty register (VENC_SWREG283) ..... | 3206 |
| 56.7.149 VENC segment 3: intra 4x4 mode 8-9 penalty, intra 4x4 previous mode favor for H.264 register (VENC_SWREG284) ..... | 3206 |
| 56.7.150 VENC segment 3: bit cost of inter type, intra 16x16 mode favor register (VENC_SWREG285) ..... | 3207 |
| 56.7.151 VENC segment 3: inter MB mode favor in intra/inter selection, inter MB mode favor, penalty value for second reference frame register (VENC_SWREG286) ..... | 3207 |
| 56.7.152 VENC segment 3: penalty value register (VENC_SWREGx) ..... | 3207 |
| 56.7.153 VENC segment 3: deadzone rate multiplier for plane 0-1 register (VENC_SWREG289) ..... | 3208 |
| 56.7.154 VENC segment 3: deadzone rate multiplier for plane 2-3 register (VENC_SWREG290) ..... | 3208 |
| 56.7.155 VENC segment 3: deadzone rate for macroblock skip token 0-1, dmv penalty coefficient register (VENC_SWREG291) ..... | 3208 |
| 56.7.156 VENC VP8 average variance in prev frame register (VENC_SWREG292) ..... | 3209 |
| 56.7.157 VENC VP8 16384/average variance in prev frame, H264 field control register (VENC_SWREG293) ..... | 3209 |
| 56.7.158 VENC Mb boost register (VENC_SWREG294) ..... | 3209 |
| 56.7.159 VENC variance control, Pskop condng mode register (VENC_SWREG295) ..... | 3210 |
| 56.7.160 VENC synthesis configuration register encoder 1 read only register (VENC_SWREG296) ..... | 3210 |
| 56.7.161 VENC MBRC control register (VENC_SWREG297) ..... | 3210 |
| 56.7.162 VENC segment 4: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG298) ..... | 3211 |
| 56.7.163 VENC segment 4: skip mode penalty, inter MB mode favor register (VENC_SWREG299) ..... | 3211 |
| 56.7.164 VENC segment 4: penalty value register (VENC_SWREGx) ..... | 3211 |
| 56.7.165 VENC segment 5: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG302) ..... | 3212 |
| 56.7.166 VENC segment 5: skip mode penalty, inter MB mode favor register (VENC_SWREG303) ..... | 3212 |
| 56.7.167 VENC segment 5: penalty value register (VENC_SWREGx) ..... | 3212 |
| 56.7.168 VENC segment 6: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG306) ..... | 3213 |
| 56.7.169 VENC segment 6: skip mode penalty, inter MB mode favor register (VENC_SWREG307) ..... | 3213 |
| 56.7.170 VENC segment 6: penalty value register (VENC_SWREGx) ..... | 3213 |
| 56.7.171 VENC segment 7: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG310) ..... | 3214 |
| 56.7.172 VENC segment 7: skip mode penalty, inter MB mode favor register (VENC_SWREG311) ..... | 3214 |
| 56.7.173 VENC segment 7: penalty value register (VENC_SWREGx) ..... | 3214 |
| 56.7.174 VENC segment 8: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG314) ..... | 3215 |
| 56.7.175 VENC segment 8: skip mode penalty, inter MB mode favor register (VENC_SWREG315) ..... | 3215 |
| 56.7.176 VENC segment 8: penalty value register (VENC_SWREGx) ..... | 3215 |
| 56.7.177 VENC segment 9: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG318) ..... | 3216 |
| 56.7.178 VENC segment 9: skip mode penalty, inter MB mode favor register (VENC_SWREG319) ..... | 3216 |
| 56.7.179 VENC segment 9: penalty value register (VENC_SWREGx) ..... | 3216 |
| 56.7.180 | VENC segment 10: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG322) ..... | 3217 |
| 56.7.181 | VENC segment 10: skip mode penalty, inter MB mode favor register (VENC_SWREG323) ..... | 3217 |
| 56.7.182 | VENC segment 10: penalty value register (VENC_SWREGx) .... | 3217 |
| 56.7.183 | VENC segment 11: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG326) ..... | 3218 |
| 56.7.184 | VENC segment 11: skip mode penalty, inter MB mode favor register (VENC_SWREG327) ..... | 3218 |
| 56.7.185 | VENC segment 11: penalty value register (VENC_SWREGx) .... | 3218 |
| 56.7.186 | VENC segment 12: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG330) ..... | 3219 |
| 56.7.187 | VENC segment 12: skip mode penalty, inter MB mode favor register (VENC_SWREG331) ..... | 3219 |
| 56.7.188 | VENC segment 12: penalty value register (VENC_SWREGx) .... | 3219 |
| 56.7.189 | VENC segment 13: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG334) ..... | 3220 |
| 56.7.190 | VENC segment 13: skip mode penalty, inter MB mode favor register (VENC_SWREG335) ..... | 3220 |
| 56.7.191 | VENC segment 13: penalty value register (VENC_SWREGx) .... | 3220 |
| 56.7.192 | VENC segment 14: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG338) ..... | 3221 |
| 56.7.193 | VENC segment 14: skip mode penalty, inter MB mode favor register (VENC_SWREG339) ..... | 3221 |
| 56.7.194 | VENC segment 14: penalty value register (VENC_SWREGx) .... | 3221 |
| 56.7.195 | VENC segment 15: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG342) ..... | 3222 |
| 56.7.196 | VENC segment 15: skip mode penalty, inter MB mode favor register (VENC_SWREG343) ..... | 3222 |
| 56.7.197 | VENC segment 15: penalty value register (VENC_SWREGx) .... | 3222 |
| 56.7.198 | VENC segment 16: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG346) ..... | 3223 |
| 56.7.199 | VENC segment 16: skip mode penalty, inter MB mode favor register (VENC_SWREG347) ..... | 3223 |
| 56.7.200 | VENC segment 16: penalty value register (VENC_SWREGx) .... | 3223 |
| 56.7.201 VENC segment 17: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG350) ..... | 3224 |
| 56.7.202 VENC segment 17: skip mode penalty, inter MB mode favor register (VENC_SWREG351) ..... | 3224 |
| 56.7.203 VENC segment 17: penalty value register (VENC_SWREGx) .... | 3224 |
| 56.7.204 VENC segment 18: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG354) ..... | 3225 |
| 56.7.205 VENC segment 18: skip mode penalty, inter MB mode favor register (VENC_SWREG355) ..... | 3225 |
| 56.7.206 VENC segment 18: penalty value register (VENC_SWREGx) .... | 3225 |
| 56.7.207 VENC segment 19: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG358) ..... | 3226 |
| 56.7.208 VENC segment 19: skip mode penalty, inter MB mode favor register (VENC_SWREG359) ..... | 3226 |
| 56.7.209 VENC segment 19: penalty value register (VENC_SWREGx) .... | 3226 |
| 56.7.210 VENC segment 20: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG362) ..... | 3227 |
| 56.7.211 VENC segment 20: skip mode penalty, inter MB mode favor register (VENC_SWREG363) ..... | 3227 |
| 56.7.212 VENC segment 20: penalty value register (VENC_SWREGx) .... | 3227 |
| 56.7.213 VENC segment 21: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG366) ..... | 3228 |
| 56.7.214 VENC segment 21: skip mode penalty, inter MB mode favor register (VENC_SWREG367) ..... | 3228 |
| 56.7.215 VENC segment 21: penalty value register (VENC_SWREGx) .... | 3228 |
| 56.7.216 VENC segment 22: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG370) ..... | 3229 |
| 56.7.217 VENC segment 22: skip mode penalty, inter MB mode favor register (VENC_SWREG371) ..... | 3229 |
| 56.7.218 VENC segment 22: penalty value register (VENC_SWREGx) .... | 3229 |
| 56.7.219 VENC segment 23: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG374) ..... | 3230 |
| 56.7.220 VENC segment 23: skip mode penalty, inter MB mode favor register (VENC_SWREG375) ..... | 3230 |
| 56.7.221 VENC segment 23: penalty value register (VENC_SWREGx) .... | 3230 |
| 56.7.222 VENC segment 24: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG378) ..... | 3231 |
| 56.7.223 VENC segment 24: skip mode penalty, inter MB mode favor register (VENC_SWREG379) ..... | 3231 |
| 56.7.224 VENC segment 24: penalty value register (VENC_SWREGx) .... | 3231 |
| 56.7.225 VENC segment 25: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG382) ..... | 3232 |
| 56.7.226 VENC segment 25: skip mode penalty, inter MB mode favor register (VENC_SWREG383) ..... | 3232 |
| 56.7.227 VENC segment 25: penalty value register (VENC_SWREGx) .... | 3232 |
| 56.7.228 VENC segment 26: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG386) ..... | 3233 |
| 56.7.229 VENC segment 26: skip mode penalty, inter MB mode favor register (VENC_SWREG387) ..... | 3233 |
| 56.7.230 VENC segment 26: penalty value register (VENC_SWREGx) .... | 3233 |
| 56.7.231 VENC segment 27: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG390) ..... | 3234 |
| 56.7.232 VENC segment 27: skip mode penalty, inter MB mode favor register (VENC_SWREG391) ..... | 3234 |
| 56.7.233 VENC segment 27: penalty value register (VENC_SWREGx) .... | 3234 |
| 56.7.234 VENC segment 28: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG394) ..... | 3235 |
| 56.7.235 VENC segment 28: skip mode penalty, inter MB mode favor register (VENC_SWREG395) ..... | 3235 |
| 56.7.236 VENC segment 28: penalty value register (VENC_SWREGx) .... | 3235 |
| 56.7.237 VENC segment 29: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG398) ..... | 3236 |
| 56.7.238 VENC segment 29: skip mode penalty, inter MB mode favor register (VENC_SWREG399) ..... | 3236 |
| 56.7.239 VENC segment 29: penalty value register (VENC_SWREGx) .... | 3236 |
| 56.7.240 VENC segment 30: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG402) ..... | 3237 |
| 56.7.241 VENC segment 30: skip mode penalty, inter MB mode favor register (VENC_SWREG403) ..... | 3237 |
| 56.7.242 VENC segment 30: penalty value register (VENC_SWREGx) .... | 3237 |
| 56.7.243 VENC segment 31: intra 4x4 previous mode favor, intra 16x16 mode favor, penalty value for second reference frame register (VENC_SWREG406) ..... | 3238 |
| 56.7.244 VENC segment 31: skip mode penalty, inter MB mode favor register (VENC_SWREG407) ..... | 3238 |
| 56.7.245 VENC segment 31: penalty value register (VENC_SWREGx) .... | 3238 |
| 56.7.246 VENC MBRC control, QP, offset, enable register (VENC_SWREG410) ..... | 3239 |
| 56.7.247 VENC gain of MB QP delta. 8.8 format register (VENC_SWREG411) ..... | 3239 |
| 56.7.248 VENC average of MB complexity register (VENC_SWREG412) ... | 3239 |
| 56.7.249 VENC reorder control register (VENC_SWREG421) ..... | 3240 |
| 56.7.250 VENC AXI read ID register (VENC_SWREG422) ..... | 3240 |
| 56.7.251 VENC base address MSB for reference luma compression table register (VENC_SWREG423) ..... | 3240 |
| 56.7.252 VENC base address MSB for reference chroma compression table register (VENC_SWREG424) ..... | 3241 |
| 56.7.253 VENC base address MSB for reconstructed luma compression table register (VENC_SWREG425) ..... | 3241 |
| 56.7.254 VENC base address for reconstructed chroma compression table register (VENC_SWREG426) ..... | 3241 |
| 56.7.255 VENC base address MSB for second reference luma compression table register (VENC_SWREG427) ..... | 3242 |
| 56.7.256 VENC base address MSB for second reference chroma compression table register (VENC_SWREG428) ..... | 3242 |
| 56.7.257 VENC high 32 bits of base address for output stream data register (VENC_SWREG429) ..... | 3242 |
| 56.7.258 VENC high 32 bits of base address for output control data register (VENC_SWREG430) ..... | 3243 |
| 56.7.259 VENC high 32 bits of base address for reference luma register (VENC_SWREG431) ..... | 3243 |
| 56.7.260 VENC high 32 bits of base address for reference chroma register (VENC_SWREG432) ..... | 3243 |
| 56.7.261 VENC high 32 bits of base address for reconstructed luma register (VENC_SWREG433) ..... | 3244 |
| 56.7.262 VENC high 32 bits of base address for reconstructed chroma register (VENC_SWREG434) ..... | 3244 |
| 56.7.263 VENC high 32 bits of base address for input picture luma register (VENC_SWREG435) ..... | 3244 |
| 56.7.264 VENC high 32 bits of base address for input picture cb register (VENC_SWREG436) ..... | 3245 |
| 56.7.265 VENC high 32 bits of base address for input picture cr register (VENC_SWREG437) ..... | 3245 |
| 56.7.266 | VENC high 32 bits of base address for second reference luma register (VENC_SWREG438) ..... | 3245 |
| 56.7.267 | VENC high 32 bits of base address for second reference chroma register (VENC_SWREG439) ..... | 3246 |
| 56.7.268 | VENC high 32 bits of H264 secondary ref pic base register (VENC_SWREGx) ..... | 3246 |
| 56.7.269 | VENC high 32 bits of base address for next pic luminance register (VENC_SWREG442) ..... | 3246 |
| 56.7.270 | VENC high 32 bits of base address for cabac context tables H264 or probability tables VP8 register (VENC_SWREG443) ..... | 3247 |
| 56.7.271 | VENC high 32 bits of base address for MV output writing register (VENC_SWREG444) ..... | 3247 |
| 56.7.272 | VENC high 32 bits of base address for VP8 1st DCT partition register (VENC_SWREG445) ..... | 3247 |
| 56.7.273 | VENC high 32 bits of base address for VP8 2nd DCT partition register (VENC_SWREG446) ..... | 3248 |
| 56.7.274 | VENC high 32 bits of base address for VP8 counters for probability updates register (VENC_SWREG447) ..... | 3248 |
| 56.7.275 | VENC high 32 bits of base address for VP8 segmentation map segment Id 2- bits/macroblock register (VENC_SWREG448) ..... | 3248 |
| 56.7.276 | VENC high 32 bits of base address for output of down-scaled encoder image in YUYV 4:2:2 format register (VENC_SWREG449) ..... | 3249 |
| 56.7.277 | VENC high 32 bits of base address for VP8 3rd DCT partition register (VENC_SWREG450) ..... | 3249 |
| 56.7.278 | VENC high 32 bits of base address for VP8 4th DCT partition register (VENC_SWREG451) ..... | 3249 |
| 56.7.279 | VENC low-latency control register (VENC_SWREG497) ..... | 3250 |
| 56.7.280 | VENC register map ..... | 3250 |
| 57 | Video decoder (VDEC) ..... | 3265 |
| 57.1 | VDEC introduction ..... | 3265 |
| 57.2 | VDEC main features ..... | 3265 |
| 57.3 | VDEC implementation ..... | 3265 |
| 57.4 | VDEC functional description ..... | 3266 |
| 57.4.1 | VDEC block diagram ..... | 3266 |
| 57.4.2 | VDEC pins and internal signals ..... | 3266 |
| 57.4.3 | VDEC reset and clocks ..... | 3266 |
| 57.4.4 | VDEC H264/VP8 decoder ..... | 3267 |
| 57.4.5 | VDEC JPEG decoder ..... | 3268 |
| 57.4.6 | VDEC security ..... | 3268 |
| 57.4.7 | VDEC power-on sequence ..... | 3268 |
| 57.4.8 | VDERAM power-on sequence for AXI access ..... | 3269 |
| 57.5 | VDEC low power modes ..... | 3269 |
| 57.6 | VDEC interrupts ..... | 3269 |
| 57.7 | VDEC registers ..... | 3270 |
| 57.7.1 | VDEC ID register (VDEC_SWREG0) ..... | 3270 |
| 57.7.2 | VDEC interrupt register decoder register (VDEC_SWREG1) ..... | 3270 |
| 57.7.3 | VDEC device configuration decoder register (VDEC_SWREG2) ... | 3270 |
| 57.7.4 | VDEC decoder control register 0, decmode, picture type (VDEC_SWREG3) ..... | 3271 |
| 57.7.5 | VDEC decoder control register 1, picture parameters (VDEC_SWREG4) ..... | 3271 |
| 57.7.6 | VDEC decoder control register 2, stream decoding table selects (VDEC_SWREG5) ..... | 3271 |
| 57.7.7 | VDEC decoder control register 3, stream buffer information (VDEC_SWREG6) ..... | 3272 |
| 57.7.8 | VDEC decoder control register 4, H264, VC-1, VP6 and progressive JPEG control (VDEC_SWREG7) ..... | 3272 |
| 57.7.9 | VDEC decoder control register 5, H264, VC-1, VP6, progressive JPEG and RV control (VDEC_SWREG8) ..... | 3272 |
| 57.7.10 | VDEC decoder control register 6/base address for MB-control, RLC /VC-1 intensity control 0/VP6,VP7,VP8 ctrl-stream length/ RV pic slice amount (VDEC_SWREG9) ..... | 3273 |
| 57.7.11 | VDEC base address for differential motion vector base address RLC-mode/H264 P initial fwd ref pic list register, 4-9/ VC-1 intensity control 1/VP7 and VP8 segmentation base register (VDEC_SWREG10) ..... | 3273 |
| 57.7.12 | VDEC decoder control register 7, VLC/base address for H.264 intra prediction 4x4/base address for MPEG-4 DC component, RLC / H264 P initial fwd ref pic list register, 10- 15/VC-1 intensity control 2 register (VDEC_SWREG11) ..... | 3274 |
| 57.7.13 | VDEC base address for RLC data, RLC/stream start address /decoded end addr register, VLC (VDEC_SWREG12) ..... | 3274 |
| 57.7.14 | VDEC base address for decoded picture/base address for JPEG decoder output luminance picture register (VDEC_SWREG13) .... | 3275 |
| 57.7.15 | VDEC base address for reference picture index 0/base address for JPEG decoder output chrominance picture register (VDEC_SWREG14) ..... | 3275 |
| 57.7.16 | VDEC base address for reference picture index 1/JPEG control register (VDEC_SWREG15) ..... | 3275 |
| 57.7.17 | VDEC base address for reference picture index 2/list of VLC code lengths in first JPEG AC table register (VDEC_SWREG16) ..... | 3276 |
| 57.7.18 | VDEC base address for reference picture index 3/list of VLC code lengths in first JPEG AC table register (VDEC_SWREG17) . . . . . | 3276 |
| 57.7.19 | VDEC base address for reference picture list of VLC code lengths in first JPEG AC table/VP8 golden refer picture base register (VDEC_SWREG18) . . . . . | 3276 |
| 57.7.20 | VDEC base address for reference picture index 5/list of VLC code lengths in first/second JPEG AC table register (VDEC_SWREG19) . | 3277 |
| 57.7.21 | VDEC base address for reference picture index 6/list of VLC code lengths in second JPEG AC table register (VDEC_SWREG20) . . . . | 3277 |
| 57.7.22 | VDEC base address for reference picture index 7/list of VLC code lengths in second JPEG AC table register (VDEC_SWREG21) . . . . | 3277 |
| 57.7.23 | VDEC base address for reference picture index 8/list of VLC code lengths in second JPEG AC table/VP7,VP8 DCT stream 1 base register (VDEC_SWREG22) | 3278 |
| 57.7.24 | VDEC base address for reference picture index 9/list of VLC code lengths in first JPEG DC table/VP6 scan maps/VP7,VP8 DCT . . stream 2 base register (VDEC_SWREG23) | 3278 |
| 57.7.25 | VDEC base address for reference picture index 10/list of VLC code lengths in first JPEG DC table/VP6 scan maps/VP7, VP8 DCT . stream 3 base register (VDEC_SWREG24) | 3279 |
| 57.7.26 | VDEC base address for reference picture index 11/list of VLC code lengths in second JPEG DC table/VP6 scan maps/VP7,VP8 DCT stream 4 base register (VDEC_SWREG25) | 3279 |
| 57.7.27 | VDEC base address for reference picture index 12/list of VLC code lengths in second JPEG DC table/VP6 scan maps/VP7, VP8 DCT stream 5 base register (VDEC_SWREG26) | 3280 |
| 57.7.28 | VDEC base address for reference picture index 13/VC-1 bitpl mbctrl or VP6, VP7, VP8 ctrl stream base/progressive JPEG DC table register (VDEC_SWREG27) . . . . . | 3280 |
| 57.7.29 | VDEC base address for reference picture index 14/VP6 scan maps /progressive JPEG DC table/VP7, VP8 DCT stream 6 base . . . . . register (VDEC_SWREG28) | 3281 |
| 57.7.30 | VDEC base address for reference picture index 15/VP6 scan maps/VP7, VP8 DCT stream 7 base register (VDEC_SWREG29) . . . . . | 3281 |
| 57.7.31 | VDEC reference picture numbers for index 0 and 1, H264 VLC /VP6 scan maps/VP7, VP8 loop filter mb level adjusts . . . . . register (VDEC_SWREG30) | 3282 |
| 57.7.32 | VDEC reference picture numbers for index 2 and 3, H264 VLC/VP6 scan maps/VP7, VP8 loop filter ref pic level adjusts register (VDEC_SWREG31) . . . . . | 3282 |
| 57.7.33 | VDEC reference picture numbers for index 4 and 5, H264 VLC/VP6 scan maps/VP7, VP8 loop filter levels register (VDEC_SWREG32) . | 3283 |
| 57.7.34 | VDEC reference picture numbers for index 6 and 7, H264 VLC /VP6 scan maps/VP7, VP8 quantization values register (VDEC_SWREG33) . . . . . | 3283 |
| 57.7.35 | VDEC reference picture numbers for index 8 and 9, H264 VLC /VP8 prediction filter taps register (VDEC_SWREG34) . . . . . | 3283 |
| 57.7.36 | VDEC reference picture numbers for index 10 and 11, H264 VLC /VP8 prediction filter taps register (VDEC_SWREG35) . . . . . | 3284 |
| 57.7.37 | VDEC reference picture numbers for index 12 and 13, H264 VLC/ VP8 prediction filter taps Register (VDEC_SWREG36) . . . . . | 3284 |
| 57.7.38 | VDEC reference picture numbers for index 14 and 15, H264 VLC /VP8 prediction filter taps register (VDEC_SWREG37) . . . . . | 3284 |
| 57.7.39 | VDEC reference picture long term flags, H264 VLC/ VP8 prediction filter taps register (VDEC_SWREG38) . . . . . | 3285 |
| 57.7.40 | VDEC reference picture valid flags, H264 VLC/ VP8 prediction filter taps register (VDEC_SWREG39) . . . . . | 3285 |
| 57.7.41 | VDEC base address for standard dependent table register (VDEC_SWREG40) . . . . . | 3285 |
| 57.7.42 | VDEC base address for direct mode motion vectors/ progressive JPEG AC/DC coefficient read/write base register (VDEC_SWREG41) . . . . . | 3286 |
| 57.7.43 | VDEC bi_dir initial ref pic list register, 0-2/VP6 prediction filter taps/progressive JPEG Cb ACDC coefficient base register (VDEC_SWREG42) . . . . . | 3286 |
| 57.7.44 | VDEC bi-dir initial ref pic list register, 3-5/VP6 prediction filter taps/progressive JPEG Cr ACDC coefficient base register (VDEC_SWREG43) . . . . . | 3287 |
| 57.7.45 | VDEC bi-dir initial ref pic list register, 6-8/VP6 prediction filter taps register (VDEC_SWREG44) . . . . . | 3287 |
| 57.7.46 | VDEC bi-dir initial ref pic list register, 9-11/VP6 prediction filter taps register (VDEC_SWREG45) . . . . . | 3287 |
| 57.7.47 | VDEC bi-dir initial ref pic list register, 12-14/VP7,VP8 quantization values register (VDEC_SWREG46) . . . . . | 3288 |
| 57.7.48 | VDEC bi-dir and P fwd initial ref pic list register, 15 and P 0-3/ VP7,VP8 quantization values register (VDEC_SWREG47) . . . . . | 3288 |
| 57.7.49 | VDEC error concealment register (VDEC_SWREG48) . . . . . | 3288 |
| 57.7.50 | VDEC prediction filter tap register for H264 (VDEC_SWREG49) . . . | 3289 |
| 57.7.51 | VDEC synthesis configuration register decoder 0 . . . (VDEC_SWREG50) 3289 | |
| 57.7.52 | VDEC reference picture buffer control register (VDEC_SWREG51) . | 3289 |
| 57.7.53 | VDEC synthesis configuration register decoder 1 (VDEC_SWREG54) . . . . . | 3290 |
| 57.7.54 | VDEC reference picture buffer 2/advanced prefetch control register (VDEC_SWREG55) . . . . . | 3290 |
| 57.7.55 | VDEC device configuration register decoder 2/multicore control register (VDEC_SWREG58) . . . . . | 3290 |
| 57.7.56 | VDEC H264 chrominance 8 pixel interleaved data base register (VDEC_SWREG59) ..... | 3291 |
| 57.7.57 | VDEC base address for H264 and AVS decoded chroma picture register (VDEC_SWREG102) ..... | 3291 |
| 57.7.58 | VDEC base address for reference chroma picture index 0 register (VDEC_SWREG103) ..... | 3291 |
| 57.7.59 | VDEC base address for reference chroma picture index 1 register (VDEC_SWREG104) ..... | 3292 |
| 57.7.60 | VDEC base address for reference chroma picture index 2 register (VDEC_SWREG105) ..... | 3292 |
| 57.7.61 | VDEC base address for reference chroma picture index 3 register (VDEC_SWREG106) ..... | 3292 |
| 57.7.62 | VDEC base address for reference chroma picture index 4 register (VDEC_SWREG107) ..... | 3293 |
| 57.7.63 | VDEC base address for reference chroma picture index 5 register (VDEC_SWREG108) ..... | 3293 |
| 57.7.64 | VDEC base address for reference chroma picture index 6 register (VDEC_SWREG109) ..... | 3293 |
| 57.7.65 | VDEC base address for reference chroma picture index 7 register (VDEC_SWREG110) ..... | 3294 |
| 57.7.66 | VDEC base address for reference chroma picture index 8 register (VDEC_SWREG111) ..... | 3294 |
| 57.7.67 | VDEC base address for reference chroma picture index 9 register (VDEC_SWREG112) ..... | 3294 |
| 57.7.68 | VDEC base address for reference chroma picture index 10 register (VDEC_SWREG113) ..... | 3295 |
| 57.7.69 | VDEC base address for reference chroma picture index 11 register (VDEC_SWREG114) ..... | 3295 |
| 57.7.70 | VDEC base address for reference chroma picture index 12 register (VDEC_SWREG115) ..... | 3295 |
| 57.7.71 | VDEC base address for reference chroma picture index 13 register (VDEC_SWREG116) ..... | 3296 |
| 57.7.72 | VDEC base address for reference chroma picture index 14 register (VDEC_SWREG117) ..... | 3296 |
| 57.7.73 | VDEC base address for reference chroma picture index 15 register (VDEC_SWREG118) ..... | 3296 |
| 57.7.74 | VDEC register map ..... | 3297 |
| 58 | True random number generator (RNG) ..... | 3301 |
| 58.1 | Introduction ..... | 3301 |
| 58.2 | RNG main features ..... | 3301 |
| 58.3 | RNG functional description ..... | 3302 |
| 58.3.1 | RNG block diagram ..... | 3302 |
| 58.3.2 | RNG internal signals ..... | 3302 |
| 58.3.3 | Random number generation ..... | 3302 |
| 58.3.4 | RNG initialization ..... | 3305 |
| 58.3.5 | RNG operation ..... | 3306 |
| 58.3.6 | RNG clocking ..... | 3308 |
| 58.3.7 | Error management ..... | 3308 |
| 58.3.8 | RNG low-power use ..... | 3309 |
| 58.4 | RNG interrupts ..... | 3310 |
| 58.5 | RNG processing time ..... | 3310 |
| 58.6 | RNG entropy source validation ..... | 3311 |
| 58.6.1 | Introduction ..... | 3311 |
| 58.6.2 | Validation conditions ..... | 3311 |
| 58.7 | RNG registers ..... | 3312 |
| 58.7.1 | RNG control register (RNG_CR) ..... | 3312 |
| 58.7.2 | RNG status register (RNG_SR) ..... | 3314 |
| 58.7.3 | RNG data register (RNG_DR) ..... | 3315 |
| 58.7.4 | RNG noise source control register (RNG_NSCR) ..... | 3316 |
| 58.7.5 | RNG health test control register (RNG_HTCR) ..... | 3317 |
| 58.7.6 | RNG hardware configuration register (RNG_HWCFGR) ..... | 3317 |
| 58.7.7 | RNG version register (RNG_VERR) ..... | 3318 |
| 58.7.8 | RNG identification register (RNG_IPIDR) ..... | 3318 |
| 58.7.9 | RNG size identification register (RNG_SIDR) ..... | 3318 |
| 58.7.10 | RNG register map ..... | 3319 |
| 59 | Secure AES coprocessor (SAES) ..... | 3320 |
| 59.1 | Introduction ..... | 3320 |
| 59.2 | SAES main features ..... | 3320 |
| 59.3 | SAES implementation ..... | 3321 |
| 59.4 | SAES functional description ..... | 3321 |
| 59.4.1 | SAES block diagram ..... | 3321 |
| 59.4.2 | SAES internal signals ..... | 3322 |
| 59.4.3 | SAES reset and clocks ..... | 3323 |
| 59.4.4 | SAES symmetric cipher implementation ..... | 3323 |
| 59.4.5 | SAES encryption or decryption typical usage ..... | 3324 |
| 59.4.6 | SAES authenticated encryption, decryption, and cipher-based message authentication . . . . . | 3326 |
| 59.4.7 | SAES ciphertext stealing and data padding . . . . . | 3327 |
| 59.4.8 | SAES suspend and resume operations . . . . . | 3327 |
| 59.4.9 | SAES basic chaining modes (ECB, CBC) . . . . . | 3328 |
| 59.4.10 | SAES counter (CTR) mode . . . . . | 3332 |
| 59.4.11 | SAES Galois/counter mode (GCM) . . . . . | 3334 |
| 59.4.12 | SAES Galois message authentication code (GMAC) . . . . . | 3338 |
| 59.4.13 | SAES counter with CBC-MAC (CCM) . . . . . | 3340 |
| 59.4.14 | SAES operation with wrapped keys . . . . . | 3345 |
| 59.4.15 | SAES operation with shared keys . . . . . | 3349 |
| 59.4.16 | SAES data registers and data swapping . . . . . | 3351 |
| 59.4.17 | SAES key registers . . . . . | 3353 |
| 59.4.18 | SAES initialization vector registers . . . . . | 3355 |
| 59.4.19 | SAES error management . . . . . | 3355 |
| 59.5 | SAES interrupts . . . . . | 3357 |
| 59.6 | SAES DMA requests . . . . . | 3357 |
| 59.7 | SAES processing latency . . . . . | 3358 |
| 59.8 | SAES registers . . . . . | 3360 |
| 59.8.1 | SAES control register (SAES_CR) . . . . . | 3360 |
| 59.8.2 | SAES status register (SAES_SR) . . . . . | 3363 |
| 59.8.3 | SAES data input register (SAES_DINR) . . . . . | 3364 |
| 59.8.4 | SAES data output register (SAES_DOUTR) . . . . . | 3365 |
| 59.8.5 | SAES key register 0 (SAES_KEYR0) . . . . . | 3365 |
| 59.8.6 | SAES key register 1 (SAES_KEYR1) . . . . . | 3366 |
| 59.8.7 | SAES key register 2 (SAES_KEYR2) . . . . . | 3366 |
| 59.8.8 | SAES key register 3 (SAES_KEYR3) . . . . . | 3366 |
| 59.8.9 | SAES initialization vector register 0 (SAES_IVR0) . . . . . | 3367 |
| 59.8.10 | SAES initialization vector register 1 (SAES_IVR1) . . . . . | 3367 |
| 59.8.11 | SAES initialization vector register 2 (SAES_IVR2) . . . . . | 3367 |
| 59.8.12 | SAES initialization vector register 3 (SAES_IVR3) . . . . . | 3368 |
| 59.8.13 | SAES key register 4 (SAES_KEYR4) . . . . . | 3368 |
| 59.8.14 | SAES key register 5 (SAES_KEYR5) . . . . . | 3368 |
| 59.8.15 | SAES key register 6 (SAES_KEYR6) . . . . . | 3369 |
| 59.8.16 | SAES key register 7 (SAES_KEYR7) . . . . . | 3369 |
| 59.8.17 | SAES suspend registers (SAES_SUSPRx) . . . . . | 3369 |
| 59.8.18 | SAES interrupt enable register (SAES_IER) . . . . . | 3370 |
| 59.8.19 | SAES interrupt status register (SAES_ISR) ..... | 3371 |
| 59.8.20 | SAES interrupt clear register (SAES_ICR) ..... | 3372 |
| 59.8.21 | SAES hardware configuration register (SAES_HWCFGR) ..... | 3373 |
| 59.8.22 | SAES version register (SAES_VERR) ..... | 3373 |
| 59.8.23 | SAES identification register (SAES_IPIDR) ..... | 3374 |
| 59.8.24 | SAES size ID register (SAES_SIDR) ..... | 3374 |
| 59.8.25 | SAES register map ..... | 3374 |
| 60 | Cryptographic processor (CRYP) ..... | 3377 |
| 60.1 | Introduction ..... | 3377 |
| 60.2 | CRYP main features ..... | 3377 |
| 60.3 | CRYP implementation ..... | 3378 |
| 60.4 | CRYP functional description ..... | 3379 |
| 60.4.1 | CRYP block diagram ..... | 3379 |
| 60.4.2 | CRYP internal signals ..... | 3380 |
| 60.4.3 | CRYP reset and clocks ..... | 3380 |
| 60.4.4 | CRYP symmetric cipher implementation ..... | 3380 |
| 60.4.5 | CRYP encryption/ decryption typical usage ..... | 3381 |
| 60.4.6 | CRYP authenticated encryption, decryption, and cipher-based message authentication ..... | 3384 |
| 60.4.7 | CRYP ciphertext stealing and data padding ..... | 3385 |
| 60.4.8 | CRYP suspend and resume operations ..... | 3385 |
| 60.4.9 | CRYP DES/TDES basic chaining modes (ECB, CBC) ..... | 3386 |
| 60.4.10 | CRYP AES basic chaining modes (ECB, CBC) ..... | 3389 |
| 60.4.11 | CRYP counter mode (AES-CTR) ..... | 3393 |
| 60.4.12 | CRYP AES Galois/counter mode (GCM) ..... | 3395 |
| 60.4.13 | CRYP AES Galois message authentication code (GMAC) ..... | 3401 |
| 60.4.14 | CRYP AES Counter with CBC-MAC (CCM) ..... | 3402 |
| 60.4.15 | AES key sharing with secure AES co-processor ..... | 3407 |
| 60.4.16 | CRYP data registers and data swapping ..... | 3408 |
| 60.4.17 | CRYP key registers ..... | 3412 |
| 60.4.18 | CRYP initialization vector registers ..... | 3413 |
| 60.4.19 | CRYP error management ..... | 3413 |
| 60.5 | CRYP interrupts ..... | 3414 |
| 60.6 | CRYP DMA requests ..... | 3415 |
| 60.7 | CRYP processing time ..... | 3416 |
| 60.8 | CRYP registers | 3417 |
| 60.8.1 | CRYP control register (CRYP_CR) | 3417 |
| 60.8.2 | CRYP status register (CRYP_SR) | 3420 |
| 60.8.3 | CRYP data input register (CRYP_DINR) | 3421 |
| 60.8.4 | CRYP data output register (CRYP_DOUTR) | 3422 |
| 60.8.5 | CRYP DMA control register (CRYP_DMACR) | 3422 |
| 60.8.6 | CRYP interrupt mask set/clear register (CRYP_IMSCR) | 3423 |
| 60.8.7 | CRYP raw interrupt status register (CRYP_RISR) | 3423 |
| 60.8.8 | CRYP masked interrupt status register (CRYP_MISR) | 3424 |
| 60.8.9 | CRYP key register 0L (CRYP_K0LR) | 3425 |
| 60.8.10 | CRYP key register 0R (CRYP_K0RR) | 3425 |
| 60.8.11 | CRYP key register 1L (CRYP_K1LR) | 3426 |
| 60.8.12 | CRYP key register 1R (CRYP_K1RR) | 3426 |
| 60.8.13 | CRYP key register 2L (CRYP_K2LR) | 3426 |
| 60.8.14 | CRYP key register 2R (CRYP_K2RR) | 3427 |
| 60.8.15 | CRYP key register 3L (CRYP_K3LR) | 3427 |
| 60.8.16 | CRYP key register 3R (CRYP_K3RR) | 3428 |
| 60.8.17 | CRYP initialization vector register 0L (CRYP_IV0LR) | 3428 |
| 60.8.18 | CRYP initialization vector register 0R (CRYP_IV0RR) | 3428 |
| 60.8.19 | CRYP initialization vector register 1L (CRYP_IV1LR) | 3429 |
| 60.8.20 | CRYP initialization vector register 1R (CRYP_IV1RR) | 3429 |
| 60.8.21 | CRYP context swap GCM-CCM registers (CRYP_CSGCMCCMxR) | 3430 |
| 60.8.22 | CRYP context swap GCM registers (CRYP_CSGCMxR) | 3430 |
| 60.8.23 | CRYP hardware configuration register (CRYP_HWCFGR) | 3431 |
| 60.8.24 | CRYP version register (CRYP_VERR) | 3431 |
| 60.8.25 | CRYP identification (CRYP_IPIDR) | 3432 |
| 60.8.26 | CRYP size identification register (CRYP_SIDR) | 3432 |
| 60.8.27 | CRYP register map | 3432 |
| 61 | Hash processor (HASH) | 3435 |
| 61.1 | Introduction | 3435 |
| 61.2 | HASH main features | 3435 |
| 61.3 | HASH implementation | 3436 |
| 61.4 | HASH functional description | 3436 |
| 61.4.1 | HASH block diagram | 3436 |
| 61.4.2 | HASH internal signals | 3437 |
| 61.4.3 | About secure hash algorithms | 3437 |
| 61.4.4 | Message data feeding ..... | 3438 |
| 61.4.5 | Message digest computing ..... | 3439 |
| 61.4.6 | Message padding ..... | 3441 |
| 61.4.7 | HMAC operation ..... | 3443 |
| 61.4.8 | HASH suspend/resume operations ..... | 3445 |
| 61.4.9 | HASH DMA interface ..... | 3447 |
| 61.4.10 | HASH error management ..... | 3448 |
| 61.4.11 | HASH processing time ..... | 3448 |
| 61.5 | HASH interrupts ..... | 3448 |
| 61.6 | HASH registers ..... | 3449 |
| 61.6.1 | HASH control register (HASH_CR) ..... | 3449 |
| 61.6.2 | HASH data input register (HASH_DIN) ..... | 3451 |
| 61.6.3 | HASH start register (HASH_STR) ..... | 3452 |
| 61.6.4 | HASH digest registers ..... | 3453 |
| 61.6.5 | HASH interrupt enable register (HASH_IMR) ..... | 3455 |
| 61.6.6 | HASH status register (HASH_SR) ..... | 3455 |
| 61.6.7 | HASH SHA-3 configuration register (HASH_SHA3CFGR) ..... | 3457 |
| 61.6.8 | HASH context swap registers ..... | 3458 |
| 61.6.9 | HASH hardware configuration register (HASH_HWCFGR) ..... | 3459 |
| 61.6.10 | HASH version register (HASH_VERR) ..... | 3459 |
| 61.6.11 | HASH identification register (HASH_IPIDR) ..... | 3460 |
| 61.6.12 | HASH size identification register (HASH_SIDR) ..... | 3460 |
| 61.6.13 | HASH register map ..... | 3460 |
| 62 | On-the-fly decryption engine (OTFDEC) ..... | 3463 |
| 62.1 | Introduction ..... | 3463 |
| 62.2 | OTFDEC main features ..... | 3463 |
| 62.3 | OTFDEC functional description ..... | 3464 |
| 62.3.1 | OTFDEC block diagram ..... | 3464 |
| 62.3.2 | OTFDEC internal signals ..... | 3464 |
| 62.3.3 | OTFDEC on-the-fly decryption ..... | 3464 |
| 62.3.4 | OTFDEC usage of AES in counter mode decryption ..... | 3466 |
| 62.3.5 | Flow control management ..... | 3467 |
| 62.3.6 | OTFDEC error management ..... | 3467 |
| 62.4 | OTFDEC interrupts ..... | 3468 |
| 62.5 | OTFDEC application information ..... | 3468 |
| 62.5.1 | OTFDEC initialization process . . . . . | 3468 |
| 62.5.2 | OTFDEC and power management . . . . . | 3469 |
| 62.5.3 | Encrypting for OTFDEC . . . . . | 3470 |
| 62.5.4 | OTFDEC key CRC source code . . . . . | 3471 |
| 62.6 | OTFDEC registers . . . . . | 3472 |
| 62.6.1 | OTFDEC control register (OTFDEC_CR) . . . . . | 3472 |
| 62.6.2 | OTFDEC region x configuration register (OTFDEC_RxCFGR) . . . . . | 3472 |
| 62.6.3 | OTFDEC region x start address register (OTFDEC_RxSTARTADDR) . . . . . | 3474 |
| 62.6.4 | OTFDEC region x end address register (OTFDEC_RxENDADDR) . . . . . | 3474 |
| 62.6.5 | OTFDEC region x nonce register 0 (OTFDEC_RxNONCER0) . . . . . | 3475 |
| 62.6.6 | OTFDEC region x nonce register 1 (OTFDEC_RxNONCER1) . . . . . | 3475 |
| 62.6.7 | OTFDEC region x key register 0 (OTFDEC_RxKEYR0) . . . . . | 3475 |
| 62.6.8 | OTFDEC region x key register 1 (OTFDEC_RxKEYR1) . . . . . | 3476 |
| 62.6.9 | OTFDEC region x key register 2 (OTFDEC_RxKEYR2) . . . . . | 3476 |
| 62.6.10 | OTFDEC region x key register 3 (OTFDEC_RxKEYR3) . . . . . | 3477 |
| 62.6.11 | OTFDEC interrupt status register (OTFDEC_ISR) . . . . . | 3477 |
| 62.6.12 | OTFDEC interrupt clear register (OTFDEC_ICR) . . . . . | 3478 |
| 62.6.13 | OTFDEC interrupt enable register (OTFDEC_IER) . . . . . | 3479 |
| 62.6.14 | OTFDEC hardware configuration register (OTFDEC_HWCFGR) . . . . . | 3479 |
| 62.6.15 | OTFDEC version register (OTFDEC_VERR) . . . . . | 3480 |
| 62.6.16 | OTFDEC identification register (OTFDEC_IPIDR) . . . . . | 3480 |
| 62.6.17 | OTFDEC size identification register (OTFDEC_SIDR) . . . . . | 3481 |
| 62.6.18 | OTFDEC register map . . . . . | 3481 |
| 63 | Public key accelerator (PKA) . . . . . | 3485 |
| 63.1 | Introduction . . . . . | 3485 |
| 63.2 | PKA main features . . . . . | 3485 |
| 63.3 | PKA functional description . . . . . | 3486 |
| 63.3.1 | PKA block diagram . . . . . | 3486 |
| 63.3.2 | PKA internal signals . . . . . | 3486 |
| 63.3.3 | PKA reset and clocks . . . . . | 3486 |
| 63.3.4 | PKA public key acceleration . . . . . | 3487 |
| 63.3.5 | Typical applications for PKA . . . . . | 3489 |
| 63.3.6 | PKA procedure to perform an operation . . . . . | 3491 |
| 63.3.7 | PKA error management . . . . . | 3492 |
| 63.4 | PKA operating modes . . . . . | 3493 |
| 63.4.1 | Introduction | 3493 |
| 63.4.2 | Montgomery parameter computation | 3494 |
| 63.4.3 | Modular addition | 3494 |
| 63.4.4 | Modular subtraction | 3495 |
| 63.4.5 | Modular and Montgomery multiplication | 3495 |
| 63.4.6 | Modular exponentiation | 3496 |
| 63.4.7 | Modular inversion | 3498 |
| 63.4.8 | Modular reduction | 3498 |
| 63.4.9 | Arithmetic addition | 3499 |
| 63.4.10 | Arithmetic subtraction | 3499 |
| 63.4.11 | Arithmetic multiplication | 3500 |
| 63.4.12 | Arithmetic comparison | 3500 |
| 63.4.13 | RSA CRT exponentiation | 3500 |
| 63.4.14 | Point on elliptic curve \(F_p\) check | 3501 |
| 63.4.15 | ECC \(F_p\) scalar multiplication | 3502 |
| 63.4.16 | ECDSA sign | 3503 |
| 63.4.17 | ECDSA verification | 3505 |
| 63.4.18 | ECC complete addition | 3506 |
| 63.4.19 | ECC double base ladder | 3506 |
| 63.4.20 | ECC projective to affine | 3507 |
| 63.5 | Example of configurations and processing times | 3508 |
| 63.5.1 | Supported elliptic curves | 3508 |
| 63.5.2 | Computation times | 3510 |
| 63.6 | PKA interrupts | 3512 |
| 63.7 | PKA registers | 3513 |
| 63.7.1 | PKA control register (PKA_CR) | 3513 |
| 63.7.2 | PKA status register (PKA_SR) | 3515 |
| 63.7.3 | PKA clear flag register (PKA_CLRFR) | 3516 |
| 63.7.4 | PKA RAM | 3516 |
| 63.7.5 | PKA hardware configuration register (PKA_HWCFGR) | 3517 |
| 63.7.6 | PKA version register (PKA_VERR) | 3517 |
| 63.7.7 | PKA identification register (PKA_IPIDR) | 3518 |
| 63.7.8 | PKA size identification register (PKA_SIDR) | 3518 |
| 63.7.9 | PKA register map | 3519 |
| 64 | Advanced-control timers (TIM1/TIM8/TIM20) | 3520 |
| 64.1 | TIM1/TIM8/TIM20 introduction | 3520 |
| 64.2 | TIM1/TIM8/TIM20 main features ..... | 3520 |
| 64.3 | TIM1/TIM8/TIM20 functional description ..... | 3521 |
| 64.3.1 | Block diagram ..... | 3521 |
| 64.3.2 | TIM1/TIM8/TIM20 pins and internal signals ..... | 3522 |
| 64.3.3 | Time-base unit ..... | 3526 |
| 64.3.4 | Counter modes ..... | 3528 |
| 64.3.5 | Repetition counter ..... | 3540 |
| 64.3.6 | External trigger input ..... | 3541 |
| 64.3.7 | Clock selection ..... | 3542 |
| 64.3.8 | Capture/compare channels ..... | 3546 |
| 64.3.9 | Input capture mode ..... | 3548 |
| 64.3.10 | PWM input mode ..... | 3549 |
| 64.3.11 | Forced output mode ..... | 3550 |
| 64.3.12 | Output compare mode ..... | 3551 |
| 64.3.13 | PWM mode ..... | 3552 |
| 64.3.14 | Asymmetric PWM mode ..... | 3560 |
| 64.3.15 | Combined PWM mode ..... | 3561 |
| 64.3.16 | Combined 3-phase PWM mode ..... | 3562 |
| 64.3.17 | Complementary outputs and dead-time insertion ..... | 3563 |
| 64.3.18 | Using the break function ..... | 3566 |
| 64.3.19 | Bidirectional break inputs ..... | 3572 |
| 64.3.20 | Clearing the tim_ocxref signal on an external event ..... | 3573 |
| 64.3.21 | 6-step PWM generation ..... | 3574 |
| 64.3.22 | One-pulse mode ..... | 3575 |
| 64.3.23 | Retriggerable One-pulse mode ..... | 3577 |
| 64.3.24 | Pulse on compare mode ..... | 3578 |
| 64.3.25 | Encoder interface mode ..... | 3580 |
| 64.3.26 | Direction bit output ..... | 3597 |
| 64.3.27 | UIF bit remapping ..... | 3598 |
| 64.3.28 | Timer input XOR function ..... | 3598 |
| 64.3.29 | Interfacing with Hall sensors ..... | 3598 |
| 64.3.30 | Timer synchronization ..... | 3600 |
| 64.3.31 | ADC triggers ..... | 3605 |
| 64.3.32 | DMA burst mode ..... | 3605 |
| 64.3.33 | TIM1/TIM8/TIM20 DMA requests ..... | 3606 |
| 64.3.34 | Debug mode ..... | 3606 |
| 64.4 | TIM1/TIM8/TIM20 low-power modes ..... | 3607 |
| 64.5 | TIM1/TIM8/TIM20 interrupts | 3607 |
| 64.6 | TIM1/TIM8/TIM20 registers | 3608 |
| 64.6.1 | TIMx control register 1 (TIMx_CR1)(x = 1, 8, 20) | 3608 |
| 64.6.2 | TIMx control register 2 (TIMx_CR2)(x = 1, 8, 20) | 3609 |
| 64.6.3 | TIMx slave mode control register (TIMx_SMCR)(x = 1, 8, 20) | 3613 |
| 64.6.4 | TIMx DMA/interrupt enable register (TIMx_DIER)(x = 1, 8, 20) | 3617 |
| 64.6.5 | TIMx status register (TIMx_SR)(x = 1, 8, 20) | 3618 |
| 64.6.6 | TIMx event generation register (TIMx_EGR)(x = 1, 8, 20) | 3621 |
| 64.6.7 | TIMx capture/compare mode register 1 (TIMx_CCMR1) (x = 1, 8, 20) | 3622 |
| 64.6.8 | TIMx capture/compare mode register 1 [alternate] (TIMx_CCMR1)(x = 1, 8, 20) | 3624 |
| 64.6.9 | TIMx capture/compare mode register 2 (TIMx_CCMR2) (x = 1, 8, 20) | 3627 |
| 64.6.10 | TIMx capture/compare mode register 2 [alternate] (TIMx_CCMR2)(x = 1, 8, 20) | 3628 |
| 64.6.11 | TIMx capture/compare enable register (TIMx_CCER)(x = 1, 8, 20) | 3631 |
| 64.6.12 | TIMx counter (TIMx_CNT)(x = 1, 8, 20) | 3635 |
| 64.6.13 | TIMx prescaler (TIMx_PSC)(x = 1, 8, 20) | 3635 |
| 64.6.14 | TIMx autoreload register (TIMx_ARR)(x = 1, 8, 20) | 3636 |
| 64.6.15 | TIMx repetition counter register (TIMx_RCR)(x = 1, 8, 20) | 3636 |
| 64.6.16 | TIMx capture/compare register 1 (TIMx_CCR1)(x = 1, 8, 20) | 3637 |
| 64.6.17 | TIMx capture/compare register 2 (TIMx_CCR2)(x = 1, 8, 20) | 3637 |
| 64.6.18 | TIMx capture/compare register 3 (TIMx_CCR3)(x = 1, 8, 20) | 3638 |
| 64.6.19 | TIMx capture/compare register 4 (TIMx_CCR4)(x = 1, 8, 20) | 3639 |
| 64.6.20 | TIMx break and dead-time register (TIMx_BDTR)(x = 1, 8, 20) | 3640 |
| 64.6.21 | TIMx capture/compare register 5 (TIMx_CCR5)(x = 1, 8, 20) | 3644 |
| 64.6.22 | TIMx capture/compare register 6 (TIMx_CCR6)(x = 1, 8, 20) | 3645 |
| 64.6.23 | TIMx capture/compare mode register 3 (TIMx_CCMR3) (x = 1, 8, 20) | 3646 |
| 64.6.24 | TIMx timer deadtime register 2 (TIMx_DTR2)(x = 1, 8, 20) | 3647 |
| 64.6.25 | TIMx timer encoder control register (TIMx_ECR)(x = 1, 8, 20) | 3648 |
| 64.6.26 | TIMx timer input selection register (TIMx_TISEL)(x = 1, 8, 20) | 3649 |
| 64.6.27 | TIMx alternate function option register 1 (TIMx_AF1)(x = 1, 8, 20) | 3650 |
| 64.6.28 | TIMx alternate function register 2 (TIMx_AF2)(x = 1, 8, 20) | 3653 |
| 64.6.29 | TIMx DMA control register (TIMx_DCR)(x = 1, 8, 20) | 3655 |
| 64.6.30 | TIMx DMA address for full transfer (TIMx_DMAR)(x = 1, 8, 20) | 3657 |
| 64.6.31 | TIMx hardware configuration 2 register (TIMx_HWCGR2)(x = 1, 8, 20) | 3657 |
| 64.6.32 | TIMx hardware configuration 1 register (TIMx_HWCFGR1)(x = 1, 8, 20) | 3658 |
| 64.6.33 | TIMx IP version register (TIMx_VERR)(x = 1, 8, 20) | 3659 |
| 64.6.34 | TIMx IP identification register (TIMx_IPIDR)(x = 1, 8, 20) | 3660 |
| 64.6.35 | TIMx size ID register (TIMx_SIDR)(x = 1, 8, 20) | 3660 |
| 64.6.36 | TIMx register map | 3660 |
| 65 | General-purpose timers (TIM2/TIM3/TIM4/TIM5) | 3664 |
| 65.1 | TIM2/TIM3/TIM4/TIM5 introduction | 3664 |
| 65.2 | TIM2/TIM3/TIM4/TIM5 main features | 3664 |
| 65.3 | TIM2/TIM3/TIM4/TIM5 implementation | 3665 |
| 65.4 | TIM2/TIM3/TIM4/TIM5 functional description | 3666 |
| 65.4.1 | Block diagram | 3666 |
| 65.4.2 | TIM2/TIM3/TIM4/TIM5 pins and internal signals | 3667 |
| 65.4.3 | Time-base unit | 3670 |
| 65.4.4 | Counter modes | 3672 |
| 65.4.5 | Clock selection | 3684 |
| 65.4.6 | Capture/compare channels | 3688 |
| 65.4.7 | Input capture mode | 3690 |
| 65.4.8 | PWM input mode | 3691 |
| 65.4.9 | Forced output mode | 3692 |
| 65.4.10 | Output compare mode | 3692 |
| 65.4.11 | PWM mode | 3694 |
| 65.4.12 | Asymmetric PWM mode | 3702 |
| 65.4.13 | Combined PWM mode | 3703 |
| 65.4.14 | Clearing the tim_ocxref signal on an external event | 3704 |
| 65.4.15 | One-pulse mode | 3706 |
| 65.4.16 | Retriggerable one-pulse mode | 3707 |
| 65.4.17 | Pulse on compare mode | 3708 |
| 65.4.18 | Encoder interface mode | 3710 |
| 65.4.19 | Direction bit output | 3728 |
| 65.4.20 | UIF bit remapping | 3729 |
| 65.4.21 | Timer input XOR function | 3729 |
| 65.4.22 | Timers and external trigger synchronization | 3729 |
| 65.4.23 | Timer synchronization | 3733 |
| 65.4.24 | ADC triggers | 3738 |
| 65.4.25 | DMA burst mode | 3739 |
| 65.4.26 | TIM2/TIM3/TIM4/TIM5 DMA requests | 3740 |
| 65.4.27 | Debug mode | 3740 |
| 65.4.28 | TIM2/TIM3/TIM4/TIM5 low-power modes | 3740 |
| 65.4.29 | TIM2/TIM3/TIM4/TIM5 interrupts | 3741 |
| 65.5 | TIM2/TIM3/TIM4/TIM5 registers | 3742 |
| 65.5.1 | TIMx control register 1 (TIMx_CR1)(x = 2 to 5) | 3742 |
| 65.5.2 | TIMx control register 2 (TIMx_CR2)(x = 2 to 5) | 3743 |
| 65.5.3 | TIMx slave mode control register (TIMx_SMCR)(x = 2 to 5) | 3745 |
| 65.5.4 | TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 2 to 5) | 3749 |
| 65.5.5 | TIMx status register (TIMx_SR)(x = 2 to 5) | 3750 |
| 65.5.6 | TIMx event generation register (TIMx_EGR)(x = 2 to 5) | 3752 |
| 65.5.7 | TIMx capture/compare mode register 1 (TIMx_CCMR1)(x = 2 to 5) | 3753 |
| 65.5.8 | TIMx capture/compare mode register 1 [alternate] (TIMx_CCMR1)(x = 2 to 5) | 3755 |
| 65.5.9 | TIMx capture/compare mode register 2 (TIMx_CCMR2)(x = 2 to 5) | 3757 |
| 65.5.10 | TIMx capture/compare mode register 2 [alternate] (TIMx_CCMR2)(x = 2 to 5) | 3758 |
| 65.5.11 | TIMx capture/compare enable register (TIMx_CCER)(x = 2 to 5) | 3761 |
| 65.5.12 | TIMx counter (TIMx_CNT)(x = 2 to 5) | 3763 |
| 65.5.13 | TIMx prescaler (TIMx_PSC)(x = 2 to 5) | 3763 |
| 65.5.14 | TIMx autoreload register (TIMx_ARR)(x = 2 to 5) | 3764 |
| 65.5.15 | TIMx capture/compare register 1 (TIMx_CCR1)(x = 2 to 5) | 3764 |
| 65.5.16 | TIMx capture/compare register 2 (TIMx_CCR2)(x = 2 to 5) | 3765 |
| 65.5.17 | TIMx capture/compare register 3 (TIMx_CCR3)(x = 2 to 5) | 3766 |
| 65.5.18 | TIMx capture/compare register 4 (TIMx_CCR4)(x = 2 to 5) | 3767 |
| 65.5.19 | TIMx timer encoder control register (TIMx_ECR)(x = 2 to 5) | 3768 |
| 65.5.20 | TIMx timer input selection register (TIMx_TISEL)(x = 2 to 5) | 3769 |
| 65.5.21 | TIMx alternate function register 1 (TIMx_AF1)(x = 2 to 5) | 3770 |
| 65.5.22 | TIMx alternate function register 2 (TIMx_AF2)(x = 2 to 5) | 3771 |
| 65.5.23 | TIMx DMA control register (TIMx_DCR)(x = 2 to 5) | 3772 |
| 65.5.24 | TIMx DMA address for full transfer (TIMx_DMAR)(x = 2 to 5) | 3773 |
| 65.5.25 | TIMx hardware configuration 2 register (TIMx_HWCFGR2)(x = 2 to 5) | 3774 |
| 65.5.26 | TIMx hardware configuration 1 register (TIMx_HWCFGR1)(x = 2 to 5) | 3775 |
| 65.5.27 | TIMx IP version register (TIMx_VERR)(x = 2 to 5) | 3776 |
| 65.5.28 | TIMx IP identification register (TIMx_IPIDR)(x = 2 to 5) | 3777 |
| 65.5.29 | TIMx size ID register (TIMx_SIDR)(x = 2 to 5) | 3777 |
| 65.5.30 | TIMx register map ..... | 3777 |
| 66 | Basic timers (TIM6/TIM7) ..... | 3780 |
| 66.1 | TIM6/TIM7 introduction ..... | 3780 |
| 66.2 | TIM6/TIM7 main features ..... | 3780 |
| 66.3 | TIM6/TIM7 functional description ..... | 3781 |
| 66.3.1 | TIM6/TIM7 block diagram ..... | 3781 |
| 66.3.2 | TIM6/TIM7 internal signals ..... | 3781 |
| 66.3.3 | TIM6/TIM7 clocks ..... | 3782 |
| 66.3.4 | Time-base unit ..... | 3782 |
| 66.3.5 | Counting mode ..... | 3784 |
| 66.3.6 | UIF bit remapping ..... | 3791 |
| 66.3.7 | ADC triggers ..... | 3792 |
| 66.3.8 | TIM6/TIM7 DMA requests ..... | 3792 |
| 66.3.9 | Debug mode ..... | 3792 |
| 66.3.10 | TIM6/TIM7 low-power modes ..... | 3792 |
| 66.3.11 | TIM6/TIM7 interrupts ..... | 3792 |
| 66.4 | TIM6/TIM7 registers ..... | 3793 |
| 66.4.1 | TIMx control register 1 (TIMx_CR1)(x = 6 to 7) ..... | 3793 |
| 66.4.2 | TIMx control register 2 (TIMx_CR2)(x = 6 to 7) ..... | 3795 |
| 66.4.3 | TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 6 to 7) ..... | 3795 |
| 66.4.4 | TIMx status register (TIMx_SR)(x = 6 to 7) ..... | 3796 |
| 66.4.5 | TIMx event generation register (TIMx_EGR)(x = 6 to 7) ..... | 3796 |
| 66.4.6 | TIMx counter (TIMx_CNT)(x = 6 to 7) ..... | 3796 |
| 66.4.7 | TIMx prescaler (TIMx_PSC)(x = 6 to 7) ..... | 3797 |
| 66.4.8 | TIMx autoreload register (TIMx_ARR)(x = 6 to 7) ..... | 3797 |
| 66.4.9 | TIMx hardware configuration 2 register (TIMx_HWCFGR2)(x = 6 to 7) ..... | 3798 |
| 66.4.10 | TIMx hardware configuration 1 register (TIMx_HWCFGR1)(x = 6 to 7) ..... | 3798 |
| 66.4.11 | TIMx IP version register (TIMx_VERR)(x = 6 to 7) ..... | 3800 |
| 66.4.12 | TIMx IP identification register (TIMx_IPIDR)(x = 6 to 7) ..... | 3800 |
| 66.4.13 | TIMx size ID register (TIMx_SIDR)(x = 6 to 7) ..... | 3800 |
| 66.4.14 | TIMx register map ..... | 3802 |
| 67 | General-purpose timers (TIM10/TIM11/TIM12/TIM13/TIM14) ..... | 3804 |
| 67.1 | TIM10/TIM11/TIM12/TIM13/TIM14 introduction ..... | 3804 |
| 67.2 | TIM12 main features ..... | 3804 |
| 67.3 | TIM10/TIM11/TIM13/TIM14 main features ..... | 3805 |
| 67.4 | TIM10/TIM11/TIM12/TIM13/TIM14 functional description ..... | 3806 |
| 67.4.1 | Block diagram ..... | 3806 |
| 67.4.2 | TIM10/TIM11/TIM12/TIM13/TIM14 pins and internal signals ..... | 3807 |
| 67.4.3 | Time-base unit ..... | 3809 |
| 67.4.4 | Counter modes ..... | 3811 |
| 67.4.5 | Clock selection ..... | 3814 |
| 67.4.6 | Capture/compare channels ..... | 3816 |
| 67.4.7 | Input capture mode ..... | 3818 |
| 67.4.8 | PWM input mode (TIM12 only) ..... | 3819 |
| 67.4.9 | Forced output mode ..... | 3820 |
| 67.4.10 | Output compare mode ..... | 3821 |
| 67.4.11 | PWM mode ..... | 3822 |
| 67.4.12 | Combined PWM mode (TIM12 only) ..... | 3827 |
| 67.4.13 | One-pulse mode ..... | 3828 |
| 67.4.14 | Retriggerable one pulse mode (TIM12 only) ..... | 3830 |
| 67.4.15 | UIF bit remapping ..... | 3831 |
| 67.4.16 | Timer input XOR function ..... | 3831 |
| 67.4.17 | TIM12 external trigger synchronization ..... | 3831 |
| 67.4.18 | Slave mode – combined reset + trigger mode ..... | 3834 |
| 67.4.19 | Slave mode – combined reset + gated mode ..... | 3834 |
| 67.4.20 | Timer synchronization (TIM12 only) ..... | 3834 |
| 67.4.21 | Using timer output as trigger for other timers (TIM10/TIM11/TIM13/TIM14 only) ..... | 3834 |
| 67.4.22 | ADC triggers (TIM12 only) ..... | 3834 |
| 67.4.23 | Debug mode ..... | 3834 |
| 67.5 | TIM10/TIM11/TIM12/TIM13/TIM14 low-power modes ..... | 3835 |
| 67.6 | TIM10/TIM11/TIM12/TIM13/TIM14 interrupts ..... | 3835 |
| 67.7 | TIM12 registers ..... | 3835 |
| 67.7.1 | TIM12 control register 1 (TIM12_CR1) ..... | 3835 |
| 67.7.2 | TIM12 control register 2 (TIM12_CR2) ..... | 3837 |
| 67.7.3 | TIM12 slave mode control register (TIM12_SMCR) ..... | 3837 |
| 67.7.4 | TIM12 interrupt enable register (TIM12_DIER) ..... | 3840 |
| 67.7.5 | TIM12 status register (TIM12_SR) ..... | 3841 |
| 67.7.6 | TIM12 event generation register (TIM12_EGR) ..... | 3842 |
| 67.7.7 | TIM12 capture/compare mode register 1 (TIM12_CCMR1) ..... | 3843 |
| 67.7.8 | TIM12 capture/compare mode register 1 [alternate] (TIM12_CCMR1) | 3844 |
| 67.7.9 | TIM12 capture/compare enable register (TIM12_CCER) | 3847 |
| 67.7.10 | TIM12 counter (TIM12_CNT) | 3848 |
| 67.7.11 | TIM12 prescaler (TIM12_PSC) | 3849 |
| 67.7.12 | TIM12 autoreload register (TIM12_ARR) | 3849 |
| 67.7.13 | TIM12 capture/compare register 1 (TIM12_CCR1) | 3850 |
| 67.7.14 | TIM12 capture/compare register 2 (TIM12_CCR2) | 3850 |
| 67.7.15 | TIM12 timer input selection register (TIM12_TISEL) | 3851 |
| 67.7.16 | TIM12 hardware configuration 2 register (TIM12_HWCFGR2) | 3852 |
| 67.7.17 | TIM12 hardware configuration 1 register (TIM12_HWCFGR1) | 3852 |
| 67.7.18 | TIM12 IP version register (TIM12_VERR) | 3854 |
| 67.7.19 | TIM12 IP identification register (TIM12_IPIDR) | 3854 |
| 67.7.20 | TIM12 size ID register (TIM12_SIDR) | 3854 |
| 67.7.21 | TIM12 register map | 3856 |
| 67.8 | TIM10/TIM11/TIM13/TIM14 registers | 3858 |
| 67.8.1 | TIMx control register 1 (TIMx_CR1)(x = 10, 11, 13, 14) | 3858 |
| 67.8.2 | TIMx interrupt enable register (TIMx_DIER)(x = 10, 11, 13, 14) | 3859 |
| 67.8.3 | TIMx status register (TIMx_SR)(x = 10, 11, 13, 14) | 3859 |
| 67.8.4 | TIMx event generation register (TIMx_EGR)(x = 10, 11, 13, 14) | 3860 |
| 67.8.5 | TIMx capture/compare mode register 1 (TIMx_CCMR1)(x = 10, 11, 13, 14) | 3861 |
| 67.8.6 | TIMx capture/compare mode register 1 [alternate] (TIMx_CCMR1)(x = 10, 11, 13, 14) | 3862 |
| 67.8.7 | TIMx capture/compare enable register (TIMx_CCER)(x = 10, 11, 13, 14) | 3864 |
| 67.8.8 | TIMx counter (TIMx_CNT)(x = 10, 11, 13, 14) | 3865 |
| 67.8.9 | TIMx prescaler (TIMx_PSC)(x = 10, 11, 13, 14) | 3866 |
| 67.8.10 | TIMx autoreload register (TIMx_ARR)(x = 10, 11, 13, 14) | 3866 |
| 67.8.11 | TIMx capture/compare register 1 (TIMx_CCR1)(x = 10, 11, 13, 14) | 3867 |
| 67.8.12 | TIMx timer input selection register (TIMx_TISEL)(x = 10, 11, 13, 14) | 3867 |
| 67.8.13 | TIMx hardware configuration 2 register (TIMx_HWCFGR2) (x = 10, 11, 13, 14) | 3868 |
| 67.8.14 | TIMx hardware configuration 1 register (TIMx_HWCFGR1) (x = 10, 11, 13, 14) | 3869 |
| 67.8.15 | TIMx IP version register (TIMx_VERR)(x = 10, 11, 13, 14) | 3870 |
| 67.8.16 | TIMx IP identification register (TIMx_IPIDR)(x = 10, 11, 13, 14) | 3871 |
| 67.8.17 | TIMx size ID register (TIMx_SIDR)(x = 10, 11, 13, 14) | 3871 |
| 67.8.18 | TIM10/TIM11/TIM13/TIM14 register map | 3872 |
| 68 | General purpose timers (TIM15/TIM16/TIM17) . . . . . | 3874 |
| 68.1 | TIM15/TIM16/TIM17 introduction . . . . . | 3874 |
| 68.2 | TIM15 main features . . . . . | 3874 |
| 68.3 | TIM16/TIM17 main features . . . . . | 3875 |
| 68.4 | TIM15/TIM16/TIM17 functional description . . . . . | 3876 |
| 68.4.1 | Block diagram . . . . . | 3876 |
| 68.4.2 | TIM15/TIM16/TIM17 pins and internal signals . . . . . | 3877 |
| 68.4.3 | Time-base unit . . . . . | 3880 |
| 68.4.4 | Counter modes . . . . . | 3882 |
| 68.4.5 | Repetition counter . . . . . | 3886 |
| 68.4.6 | Clock selection . . . . . | 3887 |
| 68.4.7 | Capture/compare channels . . . . . | 3889 |
| 68.4.8 | Input capture mode . . . . . | 3891 |
| 68.4.9 | PWM input mode (only for TIM15) . . . . . | 3893 |
| 68.4.10 | Forced output mode . . . . . | 3894 |
| 68.4.11 | Output compare mode . . . . . | 3894 |
| 68.4.12 | PWM mode . . . . . | 3896 |
| 68.4.13 | Combined PWM mode (TIM15 only) . . . . . | 3901 |
| 68.4.14 | Complementary outputs and dead-time insertion . . . . . | 3902 |
| 68.4.15 | Using the break function . . . . . | 3905 |
| 68.4.16 | Bidirectional break input . . . . . | 3909 |
| 68.4.17 | Clearing the tim_ocxref signal on an external event . . . . . | 3910 |
| 68.4.18 | 6-step PWM generation . . . . . | 3911 |
| 68.4.19 | One-pulse mode . . . . . | 3913 |
| 68.4.20 | Retriggerable one pulse mode (TIM15 only) . . . . . | 3914 |
| 68.4.21 | UIF bit remapping . . . . . | 3915 |
| 68.4.22 | Timer input XOR function (TIM15 only) . . . . . | 3915 |
| 68.4.23 | External trigger synchronization (TIM15 only) . . . . . | 3915 |
| 68.4.24 | Slave mode – combined reset + trigger mode (TIM15 only) . . . . . | 3918 |
| 68.4.25 | Slave mode – combined reset + gated mode (TIM15 only) . . . . . | 3918 |
| 68.4.26 | Timer synchronization (TIM15 only) . . . . . | 3919 |
| 68.4.27 | Using timer output as trigger for other timers (TIM16/TIM17 only) . . . . . | 3919 |
| 68.4.28 | ADC triggers (TIM15 only) . . . . . | 3919 |
| 68.4.29 | DMA burst mode . . . . . | 3919 |
| 68.4.30 | TIM15/TIM16/TIM17 DMA requests . . . . . | 3920 |
| 68.4.31 | Debug mode . . . . . | 3921 |
| 68.5 | TIM15/TIM16/TIM17 low-power modes | 3921 |
| 68.6 | TIM15/TIM16/TIM17 interrupts | 3921 |
| 68.7 | TIM15 registers | 3922 |
| 68.7.1 | TIM15 control register 1 (TIM15_CR1) | 3922 |
| 68.7.2 | TIM15 control register 2 (TIM15_CR2) | 3923 |
| 68.7.3 | TIM15 slave mode control register (TIM15_SMCR) | 3925 |
| 68.7.4 | TIM15 DMA/interrupt enable register (TIM15_DIER) | 3927 |
| 68.7.5 | TIM15 status register (TIM15_SR) | 3928 |
| 68.7.6 | TIM15 event generation register (TIM15_EGR) | 3930 |
| 68.7.7 | TIM15 capture/compare mode register 1 (TIM15_CCMR1) | 3931 |
| 68.7.8 | TIM15 capture/compare mode register 1 [alternate] (TIM15_CCMR1) | 3933 |
| 68.7.9 | TIM15 capture/compare enable register (TIM15_CCER) | 3935 |
| 68.7.10 | TIM15 counter (TIM15_CNT) | 3938 |
| 68.7.11 | TIM15 prescaler (TIM15_PSC) | 3938 |
| 68.7.12 | TIM15 autoreload register (TIM15_ARR) | 3939 |
| 68.7.13 | TIM15 repetition counter register (TIM15_RCR) | 3939 |
| 68.7.14 | TIM15 capture/compare register 1 (TIM15_CCR1) | 3940 |
| 68.7.15 | TIM15 capture/compare register 2 (TIM15_CCR2) | 3941 |
| 68.7.16 | TIM15 break and dead-time register (TIM15_BDTR) | 3941 |
| 68.7.17 | TIM15 timer deadtime register 2 (TIM15_DTR2) | 3944 |
| 68.7.18 | TIM15 input selection register (TIM15_TISEL) | 3945 |
| 68.7.19 | TIM15 alternate function register 1 (TIM15_AF1) | 3946 |
| 68.7.20 | TIM15 alternate function register 2 (TIM15_AF2) | 3948 |
| 68.7.21 | TIM15 DMA control register (TIM15_DCR) | 3949 |
| 68.7.22 | TIM15 DMA address for full transfer (TIM15_DMAR) | 3950 |
| 68.7.23 | TIM15 hardware configuration 2 register (TIM15_HWCFGR2) | 3950 |
| 68.7.24 | TIM15 hardware configuration 1 register (TIM15_HWCFGR1) | 3951 |
| 68.7.25 | TIM15 IP version register (TIM15_VERR) | 3952 |
| 68.7.26 | TIM15 IP identification register (TIM15_IPIDR) | 3953 |
| 68.7.27 | TIM15 size ID register (TIM15_SIDR) | 3953 |
| 68.7.28 | TIM15 register map | 3953 |
| 68.8 | TIM16/TIM17 registers | 3957 |
| 68.8.1 | TIMx control register 1 (TIMx_CR1)(x = 16 to 17) | 3957 |
| 68.8.2 | TIMx control register 2 (TIMx_CR2)(x = 16 to 17) | 3958 |
| 68.8.3 | TIMx DMA/interrupt enable register (TIMx_DIER)(x = 16 to 17) | 3959 |
| 68.8.4 | TIMx status register (TIMx_SR)(x = 16 to 17) | 3960 |
| 68.8.5 | TIMx event generation register (TIMx_EGR)(x = 16 to 17) . . . . . | 3961 |
| 68.8.6 | TIMx capture/compare mode register 1 (TIMx_CCMR1) (x = 16 to 17) . . . . . | 3962 |
| 68.8.7 | TIMx capture/compare mode register 1 [alternate] (TIMx_CCMR1)(x = 16 to 17) . . . . . | 3963 |
| 68.8.8 | TIMx capture/compare enable register (TIMx_CCER)(x = 16 to 17) . . . . . | 3965 |
| 68.8.9 | TIMx counter (TIMx_CNT)(x = 16 to 17) . . . . . | 3968 |
| 68.8.10 | TIMx prescaler (TIMx_PSC)(x = 16 to 17) . . . . . | 3968 |
| 68.8.11 | TIMx auto-reload register (TIMx_ARR)(x = 16 to 17) . . . . . | 3969 |
| 68.8.12 | TIMx repetition counter register (TIMx_RCR)(x = 16 to 17) . . . . . | 3969 |
| 68.8.13 | TIMx capture/compare register 1 (TIMx_CCR1)(x = 16 to 17) . . . . . | 3970 |
| 68.8.14 | TIMx break and dead-time register (TIMx_BDTR)(x = 16 to 17) . . . . . | 3971 |
| 68.8.15 | TIMx timer deadtime register 2 (TIMx_DTR2)(x = 16 to 17) . . . . . | 3974 |
| 68.8.16 | TIMx input selection register (TIMx_TISEL)(x = 16 to 17) . . . . . | 3975 |
| 68.8.17 | TIMx alternate function register 1 (TIMx_AF1)(x = 16 to 17) . . . . . | 3975 |
| 68.8.18 | TIMx alternate function register 2 (TIMx_AF2)(x = 16 to 17) . . . . . | 3978 |
| 68.8.19 | TIMx DMA control register (TIMx_DCR)(x = 16 to 17) . . . . . | 3978 |
| 68.8.20 | TIM16/TIM17 DMA address for full transfer (TIMx_DMAR)(x = 16 to 17) . . . . . | 3979 |
| 68.8.21 | TIMx hardware configuration 2 register (TIMx_HWCFGR2) (x = 16 to 17) . . . . . | 3980 |
| 68.8.22 | TIMx hardware configuration 1 register (TIMx_HWCFGR1) (x = 16 to 17) . . . . . | 3981 |
| 68.8.23 | TIMx IP version register (TIMx_VERR)(x = 16 to 17) . . . . . | 3982 |
| 68.8.24 | TIMx IP identification register (TIMx_IPIDR)(x = 16 to 17) . . . . . | 3983 |
| 68.8.25 | TIMx size ID register (TIMx_SIDR)(x = 16 to 17) . . . . . | 3983 |
| 68.8.26 | TIM16/TIM17 register map . . . . . | 3984 |
| 69 | Low-power timer (LPTIM) . . . . . | 3987 |
| 69.1 | Introduction . . . . . | 3987 |
| 69.2 | LPTIM main features . . . . . | 3987 |
| 69.3 | LPTIM implementation . . . . . | 3988 |
| 69.4 | LPTIM functional description . . . . . | 3989 |
| 69.4.1 | LPTIM block diagram . . . . . | 3989 |
| 69.4.2 | LPTIM pins and internal signals . . . . . | 3990 |
| 69.4.3 | LPTIM input and trigger mapping . . . . . | 3992 |
| 69.4.4 | LPTIM reset and clocks . . . . . | 3993 |
| 69.4.5 | Glitch filter . . . . . | 3993 |
| 69.4.6 | Prescaler ..... | 3994 |
| 69.4.7 | Trigger multiplexer ..... | 3994 |
| 69.4.8 | Operating mode ..... | 3995 |
| 69.4.9 | Timeout function ..... | 3997 |
| 69.4.10 | Waveform generation ..... | 3997 |
| 69.4.11 | Register update ..... | 3998 |
| 69.4.12 | Counter mode ..... | 3999 |
| 69.4.13 | Timer enable ..... | 4000 |
| 69.4.14 | Timer counter reset ..... | 4000 |
| 69.4.15 | Encoder mode ..... | 4001 |
| 69.4.16 | Repetition counter ..... | 4002 |
| 69.4.17 | Capture/compare channels ..... | 4003 |
| 69.4.18 | Input capture mode ..... | 4004 |
| 69.4.19 | PWM mode ..... | 4006 |
| 69.4.20 | Autonomous mode ..... | 4008 |
| 69.4.21 | DMA requests ..... | 4009 |
| 69.4.22 | Debug mode ..... | 4010 |
| 69.5 | LPTIM low-power modes ..... | 4010 |
| 69.6 | LPTIM interrupts ..... | 4010 |
| 69.7 | LPTIM registers ..... | 4011 |
| 69.7.1 | LPTIM5 interrupt and status register (LPTIM5_ISR) ..... | 4012 |
| 69.7.2 | LPTIMx interrupt and status register [alternate] (LPTIMx_ISR) (x = 1 to 4) ..... | 4013 |
| 69.7.3 | LPTIMx interrupt and status register [alternate] (LPTIMx_ISR) (x = 1 to 4) ..... | 4015 |
| 69.7.4 | LPTIM5 interrupt clear register (LPTIM5_ICR) ..... | 4017 |
| 69.7.5 | LPTIMx interrupt clear register [alternate] (LPTIMx_ICR) (x = 1 to 4) ..... | 4018 |
| 69.7.6 | LPTIMx interrupt clear register [alternate] (LPTIMx_ICR) (x = 1 to 4) ..... | 4019 |
| 69.7.7 | LPTIM5 interrupt enable register (LPTIM5_DIER) ..... | 4020 |
| 69.7.8 | LPTIMx interrupt enable register [alternate] (LPTIMx_DIER) (x = 1 to 4) ..... | 4022 |
| 69.7.9 | LPTIMx interrupt enable register [alternate] (LPTIMx_DIER) (x = 1 to 4) ..... | 4023 |
| 69.7.10 | LPTIM configuration register (LPTIM_CFGR) ..... | 4025 |
| 69.7.11 | LPTIM control register (LPTIM_CR) ..... | 4028 |
| 69.7.12 | LPTIM compare register 1 (LPTIM_CCR1) ..... | 4029 |
| 69.7.13 | LPTIM autoreload register (LPTIM_ARR) | 4030 |
| 69.7.14 | LPTIM counter register (LPTIM_CNT) | 4030 |
| 69.7.15 | LPTIM1 option register (LPTIM1_OR) | 4031 |
| 69.7.16 | LPTIM configuration register 2 (LPTIM_CFGR2) | 4031 |
| 69.7.17 | LPTIM repetition register (LPTIM_RCR) | 4032 |
| 69.7.18 | LPTIM capture/compare mode register 1 (LPTIM_CCMR1) | 4033 |
| 69.7.19 | LPTIM compare register 2 (LPTIM_CCR2) | 4035 |
| 69.7.20 | LPTIM peripheral hardware configuration register 2 (LPTIM_HWCGR2) | 4036 |
| 69.7.21 | LPTIM peripheral hardware configuration register 1 (LPTIM_HWCGR1) | 4037 |
| 69.7.22 | LPTIM peripheral version identification register (LPTIM_VERR) | 4037 |
| 69.7.23 | LPTIM peripheral type identification register (LPTIM_PIDR) | 4038 |
| 69.7.24 | LPTIM registers map size identification register (LPTIM_SIDR) | 4038 |
| 69.7.25 | LPTIM register map | 4038 |
| 70 | System timer generator (STGEN) | 4042 |
| 70.1 | STGEN introduction | 4042 |
| 70.2 | STGEN main features | 4042 |
| 70.3 | STGEN functional description | 4042 |
| 70.3.1 | STGEN block diagram | 4043 |
| 70.4 | STGEN registers | 4044 |
| 70.4.1 | STGENC control register (STGENC_CNTCR) | 4044 |
| 70.4.2 | STGENC status register (STGENC_CNTSR) | 4044 |
| 70.4.3 | STGENC value lower register (STGENC_CNTCVL) | 4045 |
| 70.4.4 | STGENC value upper register (STGENC_CNTCVU) | 4045 |
| 70.4.5 | STGENC base frequency register (STGENC_CNTFID0) | 4046 |
| 70.4.6 | STGENC peripheral ID4 register (STGENC_PIDR4) | 4046 |
| 70.4.7 | STGENC peripheral ID5 register (STGENC_PIDR5) | 4047 |
| 70.4.8 | STGENC peripheral ID6 register (STGENC_PIDR6) | 4047 |
| 70.4.9 | STGENC peripheral ID7 register (STGENC_PIDR7) | 4047 |
| 70.4.10 | STGENC peripheral ID0 register (STGENC_PIDR0) | 4048 |
| 70.4.11 | STGENC peripheral ID1 register (STGENC_PIDR1) | 4048 |
| 70.4.12 | STGENC peripheral ID2 register (STGENC_PIDR2) | 4048 |
| 70.4.13 | STGENC peripheral ID3 register (STGENC_PIDR3) | 4049 |
| 70.4.14 | STGENC component ID0 register (STGENC_CIDR0) | 4049 |
| 70.4.15 | STGENC component ID1 register (STGENC_CIDR1) | 4050 |
| 70.4.16 | STGENC component ID2 register (STGENC_CIDR2) ..... | 4050 |
| 70.4.17 | STGENC component ID3 register (STGENC_CIDR3) ..... | 4051 |
| 70.4.18 | STGENR value lower register (STGENR_CNTCVL) ..... | 4051 |
| 70.4.19 | STGENR value upper register (STGENR_CNTCVU) ..... | 4051 |
| 70.4.20 | STGENR peripheral ID4 register (STGENR_PIDR4) ..... | 4052 |
| 70.4.21 | STGENR peripheral ID5 register (STGENR_PIDR5) ..... | 4052 |
| 70.4.22 | STGENR peripheral ID6 register (STGENR_PIDR6) ..... | 4052 |
| 70.4.23 | STGENR peripheral ID7 register (STGENR_PIDR7) ..... | 4053 |
| 70.4.24 | STGENR peripheral ID0 register (STGENR_PIDR0) ..... | 4053 |
| 70.4.25 | STGENR peripheral ID1 register (STGENR_PIDR1) ..... | 4053 |
| 70.4.26 | STGENR peripheral ID2 register (STGENR_PIDR2) ..... | 4054 |
| 70.4.27 | STGENR peripheral ID3 register (STGENR_PIDR3) ..... | 4054 |
| 70.4.28 | STGENR component ID0 register (STGENR_CIDR0) ..... | 4055 |
| 70.4.29 | STGENR component ID1 register (STGENR_CIDR1) ..... | 4055 |
| 70.4.30 | STGENR component ID2 register (STGENR_CIDR2) ..... | 4055 |
| 70.4.31 | STGENR component ID3 register (STGENR_CIDR3) ..... | 4056 |
| 70.4.32 | STGEN register map ..... | 4056 |
| 71 | Watchdog overview ..... | 4059 |
| 71.1 | Watchdog main features ..... | 4059 |
| 71.2 | Watchdog functional description ..... | 4059 |
| 72 | Independent watchdog (IWDG) ..... | 4062 |
| 72.1 | Introduction ..... | 4062 |
| 72.2 | IWDG main features ..... | 4062 |
| 72.3 | IWDG implementation ..... | 4062 |
| 72.4 | IWDG functional description ..... | 4063 |
| 72.4.1 | IWDG block diagram ..... | 4063 |
| 72.4.2 | IWDG internal signals ..... | 4064 |
| 72.4.3 | Software and hardware watchdog modes ..... | 4064 |
| 72.4.4 | Window option ..... | 4065 |
| 72.4.5 | Debug ..... | 4068 |
| 72.4.6 | Register access protection ..... | 4068 |
| 72.5 | IWDG low power modes ..... | 4069 |
| 72.6 | IWDG interrupts ..... | 4069 |
| 72.7 | IWDG registers ..... | 4071 |
| 72.7.1 | IWDG key register (IWDG_KR) . . . . . | 4072 |
| 72.7.2 | IWDG prescaler register (IWDG_PR) . . . . . | 4072 |
| 72.7.3 | IWDG reload register (IWDG_RLR) . . . . . | 4073 |
| 72.7.4 | IWDG status register (IWDG_SR) . . . . . | 4073 |
| 72.7.5 | IWDG window register (IWDG_WINR) . . . . . | 4075 |
| 72.7.6 | IWDG early wake-up interrupt register (IWDG_EWCR) . . . . . | 4075 |
| 72.7.7 | IWDG interrupt clear register (IWDG_ICR) . . . . . | 4076 |
| 72.7.8 | IWDG hardware configuration register (IWDG_HWCFGR) . . . . . | 4076 |
| 72.7.9 | IWDG version register (IWDG_VERR) . . . . . | 4077 |
| 72.7.10 | IWDG identification register (IWDG_IDR) . . . . . | 4078 |
| 72.7.11 | IWDG size identification register (IWDG_SIDR) . . . . . | 4078 |
| 72.7.12 | IWDG register map . . . . . | 4079 |
| 73 | System window watchdog (WWDG) . . . . . | 4080 |
| 73.1 | Introduction . . . . . | 4080 |
| 73.2 | WWDG main features . . . . . | 4080 |
| 73.3 | WWDG implementation . . . . . | 4080 |
| 73.4 | WWDG functional description . . . . . | 4081 |
| 73.4.1 | WWDG block diagram . . . . . | 4081 |
| 73.4.2 | WWDG internal signals . . . . . | 4081 |
| 73.4.3 | Enabling the watchdog . . . . . | 4082 |
| 73.4.4 | Controlling the down-counter . . . . . | 4082 |
| 73.4.5 | How to program the watchdog timeout . . . . . | 4082 |
| 73.4.6 | Debug mode . . . . . | 4083 |
| 73.5 | WWDG interrupts . . . . . | 4084 |
| 73.6 | WWDG registers . . . . . | 4084 |
| 73.6.1 | WWDG control register (WWDG_CR) . . . . . | 4084 |
| 73.6.2 | WWDG configuration register (WWDG_CFR) . . . . . | 4085 |
| 73.6.3 | WWDG status register (WWDG_SR) . . . . . | 4085 |
| 73.6.4 | WWDG hardware configuration register (WWDG_HWCFGR) . . . . . | 4086 |
| 73.6.5 | WWDG version register (WWDG_VERR) . . . . . | 4086 |
| 73.6.6 | WWDG identification register (WWDG_IPIDR) . . . . . | 4086 |
| 73.6.7 | WWDG size identification register (WWDG_SIDR) . . . . . | 4087 |
| 73.6.8 | WWDG register map . . . . . | 4087 |
| 74 | Real-time clock (RTC) . . . . . | 4089 |
| 74.1 | Introduction | 4089 |
| 74.2 | RTC main features | 4089 |
| 74.3 | RTC functional description | 4090 |
| 74.3.1 | RTC block diagram | 4090 |
| 74.3.2 | RTC pins and internal signals | 4092 |
| 74.3.3 | GPIOs controlled by the RTC and TAMP | 4093 |
| 74.3.4 | RTC secure protection modes | 4097 |
| 74.3.5 | RTC privilege protection modes | 4098 |
| 74.3.6 | RTC compartment-based isolation | 4100 |
| 74.3.7 | Clock and prescalers | 4101 |
| 74.3.8 | Real-time clock and calendar | 4102 |
| 74.3.9 | Calendar ultra-low power mode | 4103 |
| 74.3.10 | Programmable alarms | 4103 |
| 74.3.11 | Periodic auto-wake-up | 4104 |
| 74.3.12 | RTC initialization and configuration | 4104 |
| 74.3.13 | Reading the calendar | 4107 |
| 74.3.14 | Resetting the RTC | 4108 |
| 74.3.15 | RTC synchronization | 4109 |
| 74.3.16 | RTC reference clock detection | 4109 |
| 74.3.17 | RTC smooth digital calibration | 4110 |
| 74.3.18 | Timestamp function | 4112 |
| 74.3.19 | Calibration clock output | 4113 |
| 74.3.20 | Tamper and alarm output | 4113 |
| 74.4 | RTC low-power modes | 4114 |
| 74.5 | RTC interrupts | 4114 |
| 74.6 | RTC registers | 4116 |
| 74.6.1 | RTC time register (RTC_TR) | 4117 |
| 74.6.2 | RTC date register (RTC_DR) | 4118 |
| 74.6.3 | RTC subsecond register (RTC_SSR) | 4119 |
| 74.6.4 | RTC initialization control and status register (RTC_ICSR) | 4120 |
| 74.6.5 | RTC prescaler register (RTC_PRER) | 4122 |
| 74.6.6 | RTC wake-up timer register (RTC_WUTR) | 4123 |
| 74.6.7 | RTC control register (RTC_CR) | 4123 |
| 74.6.8 | RTC privilege mode control register (RTC_PRIVCFGR) | 4127 |
| 74.6.9 | RTC secure configuration register (RTC_SECCFGR) | 4129 |
| 74.6.10 | RTC write protection register (RTC_WPR) | 4131 |
| 74.6.11 | RTC calibration register (RTC_CALR) ..... | 4131 |
| 74.6.12 | RTC shift control register (RTC_SHIFTR) ..... | 4133 |
| 74.6.13 | RTC timestamp time register (RTC_TSTR) ..... | 4134 |
| 74.6.14 | RTC timestamp date register (RTC_TSDR) ..... | 4135 |
| 74.6.15 | RTC timestamp subsecond register (RTC_TSSSR) ..... | 4136 |
| 74.6.16 | RTC alarm A register (RTC_ALRMAR) ..... | 4137 |
| 74.6.17 | RTC alarm A subsecond register (RTC_ALRMASSR) ..... | 4138 |
| 74.6.18 | RTC alarm B register (RTC_ALRMBR) ..... | 4139 |
| 74.6.19 | RTC alarm B subsecond register (RTC_ALRMBSSR) ..... | 4141 |
| 74.6.20 | RTC status register (RTC_SR) ..... | 4142 |
| 74.6.21 | RTC nonsecure masked interrupt status register (RTC_MISR) .... | 4143 |
| 74.6.22 | RTC secure masked interrupt status register (RTC_SMISR) .... | 4144 |
| 74.6.23 | RTC status clear register (RTC_SCR) ..... | 4146 |
| 74.6.24 | RTC option register (RTC_OR) ..... | 4147 |
| 74.6.25 | RTC alarm A binary mode register (RTC_ALRABINR) ..... | 4147 |
| 74.6.26 | RTC alarm B binary mode register (RTC_ALRBBINR) ..... | 4148 |
| 74.6.27 | RTC Resource x CID configuration register (RTC_RxCIDCFGR) .. | 4148 |
| 74.6.28 | RTC hardware configuration register 2 (RTC_HWCFGR2) ..... | 4149 |
| 74.6.29 | RTC hardware configuration register (RTC_HWCFGR1) ..... | 4150 |
| 74.6.30 | RTC version register (RTC_VERR) ..... | 4151 |
| 74.6.31 | RTC identification register (RTC_IPIDR) ..... | 4151 |
| 74.6.32 | RTC size identification register (RTC_SIDR) ..... | 4151 |
| 74.6.33 | RTC register map ..... | 4152 |
| 75 | Tamper and backup registers (TAMP) ..... | 4155 |
| 75.1 | Introduction ..... | 4155 |
| 75.2 | TAMP main features ..... | 4156 |
| 75.3 | TAMP functional description ..... | 4157 |
| 75.3.1 | TAMP block diagram ..... | 4157 |
| 75.3.2 | TAMP pins and internal signals ..... | 4158 |
| 75.3.3 | GPIOs controlled by the RTC and TAMP ..... | 4161 |
| 75.3.4 | TAMP register write protection ..... | 4161 |
| 75.3.5 | TAMP secure protection modes ..... | 4161 |
| 75.3.6 | Backup registers protection zones ..... | 4162 |
| 75.3.7 | TAMP privilege protection modes ..... | 4162 |
| 75.3.8 | TAMP compartment-based isolation ..... | 4163 |
| 75.3.9 | Boot hardware key (BHK) ..... | 4166 |
| 75.3.10 | Tamper detection | 4166 |
| 75.3.11 | TAMP backup registers and other device secrets erase | 4166 |
| 75.3.12 | Tamper detection configuration and initialization | 4168 |
| 75.4 | TAMP low-power modes | 4174 |
| 75.5 | TAMP interrupts | 4175 |
| 75.6 | TAMP registers | 4176 |
| 75.6.1 | TAMP control register 1 (TAMP_CR1) | 4176 |
| 75.6.2 | TAMP control register 2 (TAMP_CR2) | 4178 |
| 75.6.3 | TAMP control register 3 (TAMP_CR3) | 4181 |
| 75.6.4 | TAMP filter control register (TAMP_FLTCR) | 4183 |
| 75.6.5 | TAMP active tamper control register 1 (TAMP_ATCR1) | 4184 |
| 75.6.6 | TAMP active tamper seed register (TAMP_ATSEEDR) | 4187 |
| 75.6.7 | TAMP active tamper output register (TAMP_ATOR) | 4188 |
| 75.6.8 | TAMP active tamper control register 2 (TAMP_ATCR2) | 4188 |
| 75.6.9 | TAMP secure configuration register (TAMP_SECCFGR) | 4191 |
| 75.6.10 | TAMP privilege configuration register (TAMP_PRIVCFGR) | 4193 |
| 75.6.11 | TAMP interrupt enable register (TAMP_IER) | 4194 |
| 75.6.12 | TAMP status register (TAMP_SR) | 4196 |
| 75.6.13 | TAMP nonsecure masked interrupt status register (TAMP_MISR) | 4199 |
| 75.6.14 | TAMP secure masked interrupt status register (TAMP_SMISR) | 4200 |
| 75.6.15 | TAMP status clear register (TAMP_SCR) | 4202 |
| 75.6.16 | TAMP monotonic counter 1 register (TAMP_COUNT1R) | 4204 |
| 75.6.17 | TAMP monotonic counter 2 register (TAMP_COUNT2R) | 4205 |
| 75.6.18 | TAMP option register (TAMP_OR) | 4205 |
| 75.6.19 | TAMP resources protection configuration register (TAMP_RPCFGR) | 4206 |
| 75.6.20 | TAMP Backup registers RIF register 1(TAMP_BKPRIFR1) | 4207 |
| 75.6.21 | TAMP Backup registers RIF register 2(TAMP_BKPRIFR2) | 4207 |
| 75.6.22 | TAMP Backup registers RIF register 3(TAMP_BKPRIFR3) | 4208 |
| 75.6.23 | TAMP Resource x CID configuration register (TAMP_RxCIDCFGR) | 4208 |
| 75.6.24 | TAMP backup x register (TAMP_BKPxR) | 4209 |
| 75.6.25 | TAMP hardware configuration register 2 (TAMP_HWCFGR2) | 4210 |
| 75.6.26 | TAMP hardware configuration register 1 (TAMP_HWCFGR1) | 4211 |
| 75.6.27 | TAMP version register (TAMP_VERR) | 4211 |
| 75.6.28 | TAMP identification register (TAMP_IPIDR) | 4212 |
| 75.6.29 | TAMP size identification register (TAMP_SIDR) | 4212 |
| 75.6.30 | TAMP register map | 4213 |
| 76 | Inter-integrated circuit interface (I2C) ..... | 4216 |
| 76.1 | Introduction ..... | 4216 |
| 76.2 | I2C main features ..... | 4216 |
| 76.3 | I2C implementation ..... | 4217 |
| 76.4 | I2C functional description ..... | 4217 |
| 76.4.1 | I2C block diagram ..... | 4218 |
| 76.4.2 | I2C pins and internal signals ..... | 4218 |
| 76.4.3 | I2C clock requirements ..... | 4219 |
| 76.4.4 | I2C mode selection ..... | 4220 |
| 76.4.5 | I2C initialization ..... | 4221 |
| 76.4.6 | I2C reset ..... | 4225 |
| 76.4.7 | I2C data transfer ..... | 4225 |
| 76.4.8 | I2C slave mode ..... | 4227 |
| 76.4.9 | I2C master mode ..... | 4236 |
| 76.4.10 | I2C_TIMINGR register configuration examples ..... | 4247 |
| 76.4.11 | SMBus specific features ..... | 4249 |
| 76.4.12 | SMBus initialization ..... | 4251 |
| 76.4.13 | SMBus I2C_TIMEOUTR register configuration examples ..... | 4253 |
| 76.4.14 | SMBus slave mode ..... | 4254 |
| 76.4.15 | SMBus master mode ..... | 4257 |
| 76.4.16 | Autonomous mode ..... | 4260 |
| 76.4.17 | Error conditions ..... | 4262 |
| 76.5 | I2C in low-power modes ..... | 4263 |
| 76.6 | I2C interrupts ..... | 4264 |
| 76.7 | I2C DMA requests ..... | 4265 |
| 76.7.1 | Transmission using DMA ..... | 4265 |
| 76.7.2 | Reception using DMA ..... | 4265 |
| 76.7.3 | Master event control using DMA ..... | 4265 |
| 76.8 | I2C debug modes ..... | 4266 |
| 76.9 | I2C registers ..... | 4266 |
| 76.9.1 | I2C control register 1 (I2C_CR1) ..... | 4266 |
| 76.9.2 | I2C control register 2 (I2C_CR2) ..... | 4269 |
| 76.9.3 | I2C own address 1 register (I2C_OAR1) ..... | 4271 |
| 76.9.4 | I2C own address 2 register (I2C_OAR2) ..... | 4271 |
| 76.9.5 | I2C timing register (I2C_TIMINGR) ..... | 4272 |
| 76.9.6 | I2C timeout register (I2C_TIMEOUTR) ..... | 4273 |
| 76.9.7 | I2C interrupt and status register (I2C_ISR) ..... | 4274 |
| 76.9.8 | I2C interrupt clear register (I2C_ICR) ..... | 4277 |
| 76.9.9 | I2C PEC register (I2C_PECR) ..... | 4278 |
| 76.9.10 | I2C receive data register (I2C_RXDR) ..... | 4278 |
| 76.9.11 | I2C transmit data register (I2C_TXDR) ..... | 4279 |
| 76.9.12 | I2C autonomous mode control register (I2C_AUTOCR) ..... | 4279 |
| 76.9.13 | I2C hardware configuration register (I2C_HWCFGR) ..... | 4280 |
| 76.9.14 | I2C version register (I2C_VERR) ..... | 4281 |
| 76.9.15 | I2C identification register (I2C_IPIDR) ..... | 4281 |
| 76.9.16 | I2C size identification register (I2C_SIDR) ..... | 4281 |
| 76.9.17 | I2C register map ..... | 4282 |
| 77 | Improved inter-integrated circuit (I3C) ..... | 4284 |
| 77.1 | Introduction ..... | 4284 |
| 77.2 | I3C main features ..... | 4284 |
| 77.3 | I3C implementation ..... | 4286 |
| 77.3.1 | I3C instantiation ..... | 4286 |
| 77.3.2 | I3C wake-up from low-power mode(s) ..... | 4286 |
| 77.3.3 | I3C autonomous mode with DMA in Stop mode(s) ..... | 4286 |
| 77.3.4 | I3C FIFOs ..... | 4286 |
| 77.3.5 | I3C triggers ..... | 4287 |
| 77.3.6 | I3C interrupt(s) ..... | 4287 |
| 77.3.7 | I3C MIPI® support ..... | 4288 |
| 77.4 | I3C block diagram ..... | 4289 |
| 77.5 | I3C pins and internal signals ..... | 4289 |
| 77.6 | I3C reset and clocks ..... | 4290 |
| 77.6.1 | I3C reset ..... | 4290 |
| 77.6.2 | I3C clocks and requirements ..... | 4290 |
| 77.7 | I3C peripheral state and programming ..... | 4292 |
| 77.7.1 | I3C peripheral state ..... | 4292 |
| 77.7.2 | I3C controller state and programming sequence ..... | 4292 |
| 77.7.3 | I3C target state and programming sequence ..... | 4297 |
| 77.8 | I3C registers and programming ..... | 4301 |
| 77.8.1 | I3C register set, as controller/target ..... | 4301 |
| 77.8.2 | I3C registers and fields use versus peripheral state, as controller .. | 4302 |
| 77.8.3 | I3C registers and fields usage versus peripheral state, as target ... | 4305 |
| 77.9 | I3C bus transfers and programming . . . . . | 4307 |
| 77.9.1 | I3C command set (CCCs), as controller/target . . . . . | 4307 |
| 77.9.2 | I3C broadcast/direct CCC transfer (except ENTDAA, RSTACT), as controller . . . . . | 4311 |
| 77.9.3 | I3C broadcast ENTDAA CCC transfer, as controller . . . . . | 4313 |
| 77.9.4 | I3C broadcast/direct RSTACT CCC transfer, as controller . . . . . | 4313 |
| 77.9.5 | I3C broadcast/direct CCC transfer (except ENTDAA, DEFTGTS, DEFGRPA), as target . . . . . | 4315 |
| 77.9.6 | I3C broadcast ENTDAA CCC transfer, as target . . . . . | 4317 |
| 77.9.7 | I3C broadcast DEFTGTS CCC transfer, as target . . . . . | 4318 |
| 77.9.8 | I3C broadcast DEFGRPA CCC transfer, as target . . . . . | 4319 |
| 77.9.9 | I3C direct GETSTATUS CCC response, as target . . . . . | 4320 |
| 77.9.10 | I3C private read/write transfer, as controller . . . . . | 4321 |
| 77.9.11 | I3C private read/write transfer, as target . . . . . | 4322 |
| 77.9.12 | Legacy I2C read/write transfer, as controller . . . . . | 4323 |
| 77.9.13 | I3C IBI transfer, as controller/target . . . . . | 4324 |
| 77.9.14 | I3C hot-join request transfer, as controller/target . . . . . | 4325 |
| 77.9.15 | I3C controller-role request transfer, as controller/target . . . . . | 4326 |
| 77.10 | I3C FIFOs management, as controller . . . . . | 4327 |
| 77.10.1 | C-FIFO management, as controller . . . . . | 4327 |
| 77.10.2 | TX-FIFO management, as controller . . . . . | 4328 |
| 77.10.3 | RX-FIFO management, as controller . . . . . | 4331 |
| 77.10.4 | S-FIFO management, as controller . . . . . | 4333 |
| 77.11 | I3C FIFOs management, as target . . . . . | 4335 |
| 77.11.1 | RX-FIFO management, as target . . . . . | 4335 |
| 77.11.2 | TX-FIFO management, as target . . . . . | 4336 |
| 77.12 | I3C error management . . . . . | 4339 |
| 77.12.1 | Controller error management . . . . . | 4339 |
| 77.12.2 | Target error management . . . . . | 4341 |
| 77.13 | I3C wake-up from low-power mode(s) . . . . . | 4342 |
| 77.13.1 | Wake-up from Stop . . . . . | 4342 |
| 77.14 | I3C in low-power modes . . . . . | 4345 |
| 77.15 | I3C interrupts . . . . . | 4346 |
| 77.16 | I3C registers . . . . . | 4347 |
| 77.16.1 | I3C message control register (I3C_CR) . . . . . | 4347 |
| 77.16.2 | I3C message control register [alternate] (I3C_CR) . . . . . | 4349 |
| 77.16.3 | I3C configuration register (I3C_CFGR) . . . . . | 4351 |
| 77.16.4 | I3C receive data byte register (I3C_RDR) ..... | 4356 |
| 77.16.5 | I3C receive data word register (I3C_RDWR) ..... | 4356 |
| 77.16.6 | I3C transmit data byte register (I3C_TDR) ..... | 4357 |
| 77.16.7 | I3C transmit data word register (I3C_TDWR) ..... | 4358 |
| 77.16.8 | I3C IBI payload data register (I3C_IBIDR) ..... | 4360 |
| 77.16.9 | I3C target transmit configuration register (I3C_TGTTDR) ..... | 4361 |
| 77.16.10 | I3C status register (I3C_SR) ..... | 4362 |
| 77.16.11 | I3C status error register (I3C_SER) ..... | 4363 |
| 77.16.12 | I3C received message register (I3C_RMR) ..... | 4365 |
| 77.16.13 | I3C event register (I3C_EVR) ..... | 4366 |
| 77.16.14 | I3C interrupt enable register (I3C_IER) ..... | 4370 |
| 77.16.15 | I3C clear event register (I3C_CEV) ..... | 4372 |
| 77.16.16 | I3C own device characteristics register (I3C_DEVR0) ..... | 4374 |
| 77.16.17 | I3C device x characteristics register (I3C_DEVRx) ..... | 4376 |
| 77.16.18 | I3C maximum read length register (I3C_MAXRLR) ..... | 4378 |
| 77.16.19 | I3C maximum write length register (I3C_MAXWLR) ..... | 4379 |
| 77.16.20 | I3C timing register 0 (I3C_TIMINGR0) ..... | 4380 |
| 77.16.21 | I3C timing register 1 (I3C_TIMINGR1) ..... | 4381 |
| 77.16.22 | I3C timing register 2 (I3C_TIMINGR2) ..... | 4383 |
| 77.16.23 | I3C bus characteristics register (I3C_BCR) ..... | 4384 |
| 77.16.24 | I3C device characteristics register (I3C_DCR) ..... | 4385 |
| 77.16.25 | I3C get capability register (I3C_GETCAPR) ..... | 4386 |
| 77.16.26 | I3C controller-role capability register (I3C_CRCAPR) ..... | 4387 |
| 77.16.27 | I3C get max data speed register (I3C_GETMXDSR) ..... | 4388 |
| 77.16.28 | I3C extended provisioned ID register (I3C_EPIDR) ..... | 4390 |
| 77.16.29 | I3C hardware configuration register (I3C_HWCFGR) ..... | 4391 |
| 77.16.30 | I3C version register (I3C_VERR) ..... | 4391 |
| 77.16.31 | I3C identification register (I3C_IPIR) ..... | 4392 |
| 77.16.32 | I3C size identification register (I3C_SIDR) ..... | 4392 |
| 77.16.33 | I3C register map ..... | 4392 |
| 78 | Universal synchronous/asynchronous receiver transmitter (USART/UART) ..... | 4396 |
| 78.1 | Introduction ..... | 4396 |
| 78.2 | USART main features ..... | 4396 |
| 78.3 | USART extended features ..... | 4397 |
| 78.4 | USART implementation ..... | 4397 |
| 78.5 | USART functional description | 4399 |
| 78.5.1 | USART block diagram | 4399 |
| 78.5.2 | USART pins and internal signals | 4399 |
| 78.5.3 | USART clocks | 4402 |
| 78.5.4 | USART character description | 4402 |
| 78.5.5 | USART FIFOs and thresholds | 4404 |
| 78.5.6 | USART transmitter | 4404 |
| 78.5.7 | USART receiver | 4407 |
| 78.5.8 | USART baud rate generation | 4414 |
| 78.5.9 | Tolerance of the USART receiver to clock deviation | 4416 |
| 78.5.10 | USART auto baud rate detection | 4417 |
| 78.5.11 | USART multiprocessor communication | 4419 |
| 78.5.12 | USART Modbus communication | 4421 |
| 78.5.13 | USART parity control | 4422 |
| 78.5.14 | USART LIN (local interconnection network) mode | 4423 |
| 78.5.15 | USART synchronous mode | 4425 |
| 78.5.16 | USART single-wire half-duplex communication | 4429 |
| 78.5.17 | USART receiver timeout | 4429 |
| 78.5.18 | USART smartcard mode | 4430 |
| 78.5.19 | USART IrDA SIR ENDEC block | 4434 |
| 78.5.20 | Continuous communication using USART and DMA | 4437 |
| 78.5.21 | RS232 hardware flow control and RS485 driver enable | 4439 |
| 78.5.22 | USART autonomous mode | 4441 |
| 78.6 | USART in low-power modes | 4443 |
| 78.7 | USART interrupts | 4443 |
| 78.8 | USART registers | 4446 |
| 78.8.1 | USART control register 1 (USART_CR1) | 4446 |
| 78.8.2 | USART control register 1 [alternate] (USART_CR1) | 4450 |
| 78.8.3 | USART control register 2 (USART_CR2) | 4453 |
| 78.8.4 | USART control register 3 (USART_CR3) | 4457 |
| 78.8.5 | USART control register 3 [alternate] (USART_CR3) | 4461 |
| 78.8.6 | USART baud rate register (USART_BRR) | 4464 |
| 78.8.7 | USART guard time and prescaler register (USART_GTPR) | 4465 |
| 78.8.8 | USART receiver timeout register (USART_RTOR) | 4466 |
| 78.8.9 | USART request register (USART_RQR) | 4467 |
| 78.8.10 | USART interrupt and status register (USART_ISR) | 4468 |
| 78.8.11 | USART interrupt and status register [alternate] (USART_ISR) | 4474 |
| 78.8.12 | USART interrupt flag clear register (USART_ICR) ..... | 4479 |
| 78.8.13 | USART receive data register (USART_RDR) ..... | 4480 |
| 78.8.14 | USART transmit data register (USART_TDR) ..... | 4481 |
| 78.8.15 | USART prescaler register (USART_PRESC) ..... | 4481 |
| 78.8.16 | USART autonomous mode control register (USART_AUTOCR) .... | 4482 |
| 78.8.17 | USART hardware configuration register 2 (USART_HWCFGR2) ... | 4483 |
| 78.8.18 | USART hardware configuration register 1 (USART_HWCFGR1) ... | 4484 |
| 78.8.19 | USART version register (USART_VERR) ..... | 4484 |
| 78.8.20 | USART identification register (USART_IPIDR) ..... | 4485 |
| 78.8.21 | USART size identification register (USART_SIDR) ..... | 4485 |
| 78.8.22 | USART register map ..... | 4486 |
| 79 | Low-power universal asynchronous receiver transmitter (LPUART) ..... | 4488 |
| 79.1 | Introduction ..... | 4488 |
| 79.2 | LPUART main features ..... | 4488 |
| 79.3 | LPUART implementation ..... | 4489 |
| 79.4 | LPUART functional description ..... | 4491 |
| 79.4.1 | LPUART block diagram ..... | 4491 |
| 79.4.2 | LPUART pins and internal signals ..... | 4492 |
| 79.4.3 | LPUART clocks ..... | 4494 |
| 79.4.4 | LPUART character description ..... | 4494 |
| 79.4.5 | LPUART FIFOs and thresholds ..... | 4496 |
| 79.4.6 | LPUART transmitter ..... | 4496 |
| 79.4.7 | LPUART receiver ..... | 4500 |
| 79.4.8 | LPUART baud rate generation ..... | 4504 |
| 79.4.9 | Tolerance of the LPUART receiver to clock deviation ..... | 4505 |
| 79.4.10 | LPUART multiprocessor communication ..... | 4506 |
| 79.4.11 | LPUART parity control ..... | 4508 |
| 79.4.12 | LPUART single-wire half-duplex communication ..... | 4509 |
| 79.4.13 | Continuous communication using DMA and LPUART ..... | 4509 |
| 79.4.14 | RS232 hardware flow control and RS485 driver enable ..... | 4512 |
| 79.4.15 | LPUART autonomous mode ..... | 4514 |
| 79.5 | LPUART in low-power modes ..... | 4516 |
| 79.6 | LPUART interrupts ..... | 4517 |
| 79.7 | LPUART registers ..... | 4518 |
| 79.7.1 | LPUART control register 1 (LPUART_CR1) . . . . . | 4518 |
| 79.7.2 | LPUART control register 1 [alternate] (LPUART_CR1) . . . . . | 4521 |
| 79.7.3 | LPUART control register 2 (LPUART_CR2) . . . . . | 4525 |
| 79.7.4 | LPUART control register 3 (LPUART_CR3) . . . . . | 4526 |
| 79.7.5 | LPUART control register 3 [alternate] (LPUART_CR3) . . . . . | 4529 |
| 79.7.6 | LPUART baud rate register (LPUART_BRR) . . . . . | 4531 |
| 79.7.7 | LPUART request register (LPUART_RQR) . . . . . | 4531 |
| 79.7.8 | LPUART interrupt and status register (LPUART_ISR) . . . . . | 4532 |
| 79.7.9 | LPUART interrupt and status register [alternate] (LPUART_ISR) . . . . . | 4537 |
| 79.7.10 | LPUART interrupt flag clear register (LPUART_ICR) . . . . . | 4540 |
| 79.7.11 | LPUART receive data register (LPUART_RDR) . . . . . | 4541 |
| 79.7.12 | LPUART transmit data register (LPUART_TDR) . . . . . | 4541 |
| 79.7.13 | LPUART prescaler register (LPUART_PRESC) . . . . . | 4542 |
| 79.7.14 | LPUART autonomous mode control register (LPUART_AUTOCR) . . . . . | 4543 |
| 79.7.15 | LPUART hardware configuration register 2 (LPUART_HWCFGR2) . . . . . | 4544 |
| 79.7.16 | LPUART hardware configuration register 1 (LPUART_HWCFGR1) . . . . . | 4544 |
| 79.7.17 | LPUART version register (LPUART_VERR) . . . . . | 4545 |
| 79.7.18 | LPUART identification register (LPUART_IPIDR) . . . . . | 4545 |
| 79.7.19 | LPUART size identification register (LPUART_SIDR) . . . . . | 4546 |
| 79.7.20 | LPUART register map . . . . . | 4546 |
| 80 | Serial peripheral interface (SPI) . . . . . | 4548 |
| 80.1 | Introduction . . . . . | 4548 |
| 80.2 | SPI main features . . . . . | 4548 |
| 80.3 | SPI implementation . . . . . | 4549 |
| 80.4 | SPI functional description . . . . . | 4550 |
| 80.4.1 | SPI block diagram . . . . . | 4550 |
| 80.4.2 | SPI pins and internal signals . . . . . | 4551 |
| 80.4.3 | SPI communication general aspects . . . . . | 4553 |
| 80.4.4 | Communications between one master and one slave . . . . . | 4553 |
| 80.4.5 | Standard multislave communication . . . . . | 4556 |
| 80.4.6 | Multimaster communication . . . . . | 4558 |
| 80.4.7 | Slave select (SS) pin management . . . . . | 4559 |
| 80.4.8 | Ready pin (RDY) management . . . . . | 4563 |
| 80.4.9 | Communication formats . . . . . | 4563 |
| 80.4.10 | Configuring the SPI . . . . . | 4565 |
| 80.4.11 | Enabling the SPI . . . . . | 4566 |
| 80.4.12 | SPI data transmission and reception procedures ..... | 4567 |
| 80.4.13 | Disabling the SPI ..... | 4571 |
| 80.4.14 | Data packing ..... | 4572 |
| 80.4.15 | Communication using DMA (direct memory addressing) ..... | 4574 |
| 80.4.16 | Autonomous mode ..... | 4575 |
| 80.5 | SPI specific modes and control ..... | 4577 |
| 80.5.1 | TI mode ..... | 4577 |
| 80.5.2 | SPI error flags ..... | 4577 |
| 80.5.3 | CRC computation ..... | 4580 |
| 80.6 | SPI in low-power modes ..... | 4582 |
| 80.7 | SPI interrupts ..... | 4582 |
| 80.8 | I2S main features ..... | 4584 |
| 80.9 | I2S functional description ..... | 4584 |
| 80.9.1 | I2S general description ..... | 4584 |
| 80.9.2 | Pin sharing with SPI function ..... | 4585 |
| 80.9.3 | Bitfields usable in I2S/PCM mode ..... | 4585 |
| 80.9.4 | Slave and master modes ..... | 4586 |
| 80.9.5 | Supported audio protocols ..... | 4586 |
| 80.9.6 | Additional serial interface flexibility ..... | 4592 |
| 80.9.7 | Startup sequence ..... | 4594 |
| 80.9.8 | Stop sequence ..... | 4596 |
| 80.9.9 | Clock generator ..... | 4597 |
| 80.9.10 | Internal FIFOs ..... | 4599 |
| 80.9.11 | FIFO status flags ..... | 4600 |
| 80.9.12 | Handling of underrun situation ..... | 4600 |
| 80.9.13 | Handling of overrun situation ..... | 4601 |
| 80.9.14 | Frame error detection ..... | 4602 |
| 80.9.15 | DMA interface ..... | 4604 |
| 80.9.16 | Autonomous mode ..... | 4604 |
| 80.9.17 | Programing examples ..... | 4604 |
| 80.10 | I2S interrupts ..... | 4607 |
| 80.11 | SPI/I2S registers ..... | 4607 |
| 80.11.1 | SPI/I2S control register 1 (SPI_CR1) ..... | 4607 |
| 80.11.2 | SPI/I2S control register 2 (SPI_CR2) ..... | 4609 |
| 80.11.3 | SPI/I2S configuration register 1 (SPI_CFG1) ..... | 4610 |
| 80.11.4 | SPI/I2S configuration register 2 (SPI_CFG2) ..... | 4613 |
| 80.11.5 | SPI/I2S interrupt enable register (SPI_IER) . . . . . | 4615 |
| 80.11.6 | SPI/I2S status register (SPI_SR) . . . . . | 4616 |
| 80.11.7 | SPI/I2S interrupt/status flags clear register (SPI_IFCR) . . . . . | 4619 |
| 80.11.8 | SPI/I2S autonomous mode control register (SPI_AUTOCR) . . . . . | 4620 |
| 80.11.9 | SPI/I2S transmit data register (SPI_TXDR) . . . . . | 4620 |
| 80.11.10 | SPI/I2S receive data register (SPI_RXDR) . . . . . | 4621 |
| 80.11.11 | SPI/I2S polynomial register (SPI_CRCPOLY) . . . . . | 4622 |
| 80.11.12 | SPI/I2S transmitter CRC register (SPI_TXCRC) . . . . . | 4622 |
| 80.11.13 | SPI/I2S receiver CRC register (SPI_RXCRC) . . . . . | 4623 |
| 80.11.14 | SPI/I2S underrun data register (SPI_UDRDR) . . . . . | 4624 |
| 80.11.15 | SPI/I2S configuration register (SPI_I2SCFGR) . . . . . | 4624 |
| 80.11.16 | SPI/I2S hardware configuration register (SPI_HWCFGR2) . . . . . | 4626 |
| 80.11.17 | SPI/I2S hardware configuration register (SPI_HWCFGR1) . . . . . | 4627 |
| 80.11.18 | SPI/I2S version register (SPI_VERR) . . . . . | 4628 |
| 80.11.19 | SPI/I2S identification register (SPI_IPIR) . . . . . | 4628 |
| 80.11.20 | SPI/I2S size identification register (SPI_SIDR) . . . . . | 4629 |
| 80.11.21 | SPI/I2S register map . . . . . | 4629 |
| 81 | Serial audio interface (SAI) . . . . . | 4631 |
| 81.1 | Introduction . . . . . | 4631 |
| 81.2 | SAI main features . . . . . | 4631 |
| 81.3 | SAI implementation . . . . . | 4632 |
| 81.4 | SAI functional description . . . . . | 4633 |
| 81.4.1 | SAI block diagram . . . . . | 4633 |
| 81.4.2 | SAI pins and internal signals . . . . . | 4634 |
| 81.4.3 | Main SAI modes . . . . . | 4635 |
| 81.4.4 | SAI synchronization mode . . . . . | 4636 |
| 81.4.5 | Audio data size . . . . . | 4637 |
| 81.4.6 | Frame synchronization . . . . . | 4637 |
| 81.4.7 | Slot configuration . . . . . | 4640 |
| 81.4.8 | SAI clock generator . . . . . | 4642 |
| 81.4.9 | Internal FIFOs . . . . . | 4645 |
| 81.4.10 | PDM interface . . . . . | 4647 |
| 81.4.11 | AC'97 link controller . . . . . | 4655 |
| 81.4.12 | SPDIF output . . . . . | 4657 |
| 81.4.13 | Specific features . . . . . | 4660 |
| 81.4.14 | Error flags . . . . . | 4664 |
| 81.4.15 | Disabling the SAI | 4667 |
| 81.4.16 | SAI DMA interface | 4667 |
| 81.5 | SAI interrupts | 4668 |
| 81.6 | SAI registers | 4670 |
| 81.6.1 | SAI global configuration register (SAI_GCR) | 4670 |
| 81.6.2 | SAI configuration register 1 (SAI_ACR1) | 4670 |
| 81.6.3 | SAI configuration register 2 (SAI_ACR2) | 4673 |
| 81.6.4 | SAI frame configuration register (SAI_AFRCR) | 4675 |
| 81.6.5 | SAI slot register (SAI_ASLOTR) | 4676 |
| 81.6.6 | SAI interrupt mask register (SAI_AIM) | 4677 |
| 81.6.7 | SAI status register (SAI_ASR) | 4678 |
| 81.6.8 | SAI clear flag register (SAI_ACLRFR) | 4680 |
| 81.6.9 | SAI data register (SAI_ADR) | 4681 |
| 81.6.10 | SAI configuration register 1 (SAI_BCR1) | 4682 |
| 81.6.11 | SAI configuration register 2 (SAI_BCR2) | 4684 |
| 81.6.12 | SAI frame configuration register (SAI_BFRCR) | 4686 |
| 81.6.13 | SAI slot register (SAI_BSLOTR) | 4687 |
| 81.6.14 | SAI interrupt mask register (SAI_BIM) | 4688 |
| 81.6.15 | SAI status register (SAI_BSR) | 4690 |
| 81.6.16 | SAI clear flag register (SAI_BCLRFR) | 4692 |
| 81.6.17 | SAI data register (SAI_BDR) | 4693 |
| 81.6.18 | SAI PDM control register (SAI_PDMCR) | 4693 |
| 81.6.19 | SAI PDM delay register (SAI_PDMDLY) | 4694 |
| 81.6.20 | SAI hardware configuration register (SAI_HWCFGR) | 4696 |
| 81.6.21 | SAI version register (SAI_VERR) | 4697 |
| 81.6.22 | SAI identification register (SAI_IPIDR) | 4698 |
| 81.6.23 | SAI size identification register (SAI_SIDR) | 4698 |
| 81.6.24 | SAI register map | 4698 |
| 82 | SPDIF receiver interface (SPDIFRX) | 4701 |
| 82.1 | SPDIFRX interface introduction | 4701 |
| 82.2 | SPDIFRX main features | 4701 |
| 82.3 | SPDIFRX functional description | 4701 |
| 82.3.1 | SPDIFRX pins and internal signals | 4702 |
| 82.3.2 | S/PDIF protocol (IEC-60958) | 4703 |
| 82.3.3 | SPDIFRX decoder (SPDIFRX_DC) | 4705 |
| 82.3.4 | SPDIFRX tolerance to clock deviation | 4709 |
| 82.3.5 | SPDIFRX synchronization | 4709 |
| 82.3.6 | SPDIFRX handling | 4711 |
| 82.3.7 | Data reception management | 4713 |
| 82.3.8 | Dedicated control flow | 4715 |
| 82.3.9 | Reception errors | 4716 |
| 82.3.10 | Clocking strategy | 4718 |
| 82.3.11 | Symbol clock generation | 4718 |
| 82.3.12 | DMA interface | 4720 |
| 82.3.13 | Interrupt generation | 4721 |
| 82.3.14 | Register protection | 4722 |
| 82.4 | Programming procedures | 4722 |
| 82.4.1 | Initialization phase | 4723 |
| 82.4.2 | Handling of interrupts coming from SPDIFRX | 4724 |
| 82.4.3 | Handling of interrupts coming from DMA | 4724 |
| 82.5 | SPDIFRX interface registers | 4725 |
| 82.5.1 | SPDIFRX control register (SPDIFRX_CR) | 4725 |
| 82.5.2 | SPDIFRX interrupt mask register (SPDIFRX_IMR) | 4727 |
| 82.5.3 | SPDIFRX status register (SPDIFRX_SR) | 4728 |
| 82.5.4 | SPDIFRX interrupt flag clear register (SPDIFRX_IFCR) | 4730 |
| 82.5.5 | SPDIFRX data input register (SPDIFRX_FMT0_DR) | 4731 |
| 82.5.6 | SPDIFRX data input register (SPDIFRX_FMT1_DR) | 4731 |
| 82.5.7 | SPDIFRX data input register (SPDIFRX_FMT2_DR) | 4732 |
| 82.5.8 | SPDIFRX channel status register (SPDIFRX_CSR) | 4733 |
| 82.5.9 | SPDIFRX debug information register (SPDIFRX_DIR) | 4733 |
| 82.5.10 | SPDIFRX version register (SPDIFRX_VERR) | 4734 |
| 82.5.11 | SPDIFRX identification register (SPDIFRX_IPIDR) | 4734 |
| 82.5.12 | SPDIFRX size identification register (SPDIFRX_SIDR) | 4735 |
| 82.5.13 | SPDIFRX interface register map | 4735 |
| 83 | Controller area network with flexible data rate (FDCAN) | 4737 |
| 83.1 | Introduction | 4737 |
| 83.2 | FDCAN main features | 4740 |
| 83.3 | FDCAN implementation | 4740 |
| 83.4 | FDCAN functional description | 4741 |
| 83.4.1 | Operating modes | 4742 |
| 83.4.2 | Error management | 4751 |
| 83.4.3 | Message RAM ..... | 4751 |
| 83.4.4 | FIFO acknowledge handling ..... | 4763 |
| 83.4.5 | Bit timing ..... | 4764 |
| 83.4.6 | Clock calibration on CAN ..... | 4765 |
| 83.4.7 | Application ..... | 4769 |
| 83.4.8 | TTCAN operations (FDCAN1 only) ..... | 4770 |
| 83.4.9 | TTCAN configuration ..... | 4771 |
| 83.4.10 | Message scheduling ..... | 4773 |
| 83.4.11 | TTCAN gap control ..... | 4780 |
| 83.4.12 | Stop watch ..... | 4781 |
| 83.4.13 | Local time, cycle time, global time, and external clock synchronization ..... | 4781 |
| 83.4.14 | TTCAN error level ..... | 4784 |
| 83.4.15 | TTCAN message handling ..... | 4785 |
| 83.4.16 | TTCAN interrupt and error handling ..... | 4788 |
| 83.4.17 | Level 0 ..... | 4789 |
| 83.4.18 | Synchronization to external time schedule ..... | 4791 |
| 83.4.19 | FDCAN Rx buffer and FIFO element ..... | 4792 |
| 83.4.20 | FDCAN Tx buffer element ..... | 4794 |
| 83.4.21 | FDCAN Tx event FIFO element ..... | 4796 |
| 83.4.22 | FDCAN standard message ID filter element ..... | 4797 |
| 83.4.23 | FDCAN extended message ID filter element ..... | 4799 |
| 83.4.24 | FDCAN trigger memory element ..... | 4800 |
| 83.5 | FDCAN registers ..... | 4802 |
| 83.5.1 | FDCAN core release register (FDCAN_CREL) ..... | 4802 |
| 83.5.2 | FDCAN Endian register (FDCAN_ENDN) ..... | 4802 |
| 83.5.3 | FDCAN data bit timing and prescaler register (FDCAN_DBTP) .... | 4802 |
| 83.5.4 | FDCAN test register (FDCAN_TEST) ..... | 4803 |
| 83.5.5 | FDCAN RAM watchdog register (FDCAN_RWD) ..... | 4804 |
| 83.5.6 | FDCAN CC control register (FDCAN_CCCR) ..... | 4805 |
| 83.5.7 | FDCAN nominal bit timing and prescaler register (FDCAN_NBTP) . | 4807 |
| 83.5.8 | FDCAN timestamp counter configuration register (FDCAN_TSCC) . | 4808 |
| 83.5.9 | FDCAN timestamp counter value register (FDCAN_TSCV) ..... | 4808 |
| 83.5.10 | FDCAN timeout counter configuration register (FDCAN_TOCC) ... | 4809 |
| 83.5.11 | FDCAN timeout counter value register (FDCAN_TOCV) ..... | 4810 |
| 83.5.12 | FDCAN error counter register (FDCAN_ECR) ..... | 4810 |
| 83.5.13 | FDCAN protocol status register (FDCAN_PSR) ..... | 4811 |
| 83.5.14 | FDCAN transmitter delay compensation register (FDCAN_TDCR) .. | 4813 |
| 83.5.15 | FDCAN interrupt register (FDCAN_IR) ..... | 4813 |
| 83.5.16 | FDCAN interrupt enable register (FDCAN_IE) ..... | 4816 |
| 83.5.17 | FDCAN interrupt line select register (FDCAN_ILS) ..... | 4818 |
| 83.5.18 | FDCAN interrupt line enable register (FDCAN_ILE) ..... | 4819 |
| 83.5.19 | FDCAN global filter configuration register (FDCAN_GFC) ..... | 4820 |
| 83.5.20 | FDCAN standard ID filter configuration register (FDCAN_SIDFC) .. | 4821 |
| 83.5.21 | FDCAN extended ID filter configuration register (FDCAN_XIDFC) .. | 4822 |
| 83.5.22 | FDCAN extended ID and mask register (FDCAN_XIDAM) ..... | 4822 |
| 83.5.23 | FDCAN high priority message status register (FDCAN_HPMS) .... | 4823 |
| 83.5.24 | FDCAN new data 1 register (FDCAN_NDAT1) ..... | 4824 |
| 83.5.25 | FDCAN new data 2 register (FDCAN_NDAT2) ..... | 4824 |
| 83.5.26 | FDCAN Rx FIFO 0 configuration register (FDCAN_RXF0C) ..... | 4825 |
| 83.5.27 | FDCAN Rx FIFO 0 status register (FDCAN_RXF0S) ..... | 4825 |
| 83.5.28 | FDCAN Rx FIFO 0 acknowledge register (FDCAN_RXF0A) ..... | 4826 |
| 83.5.29 | FDCAN Rx buffer configuration register (FDCAN_RXBC) ..... | 4827 |
| 83.5.30 | FDCAN Rx FIFO 1 configuration register (FDCAN_RXF1C) ..... | 4827 |
| 83.5.31 | FDCAN Rx FIFO 1 status register (FDCAN_RXF1S) ..... | 4828 |
| 83.5.32 | FDCAN Rx FIFO 1 acknowledge register (FDCAN_RXF1A) ..... | 4829 |
| 83.5.33 | FDCAN Rx buffer element size configuration register (FDCAN_RXESC) ..... | 4829 |
| 83.5.34 | FDCAN Tx buffer configuration register (FDCAN_TXBC) ..... | 4830 |
| 83.5.35 | FDCAN Tx FIFO/queue status register (FDCAN_TXFQS) ..... | 4831 |
| 83.5.36 | FDCAN Tx buffer element size configuration register (FDCAN_TXESC) ..... | 4832 |
| 83.5.37 | FDCAN Tx buffer request pending register (FDCAN_TXBRP) .... | 4833 |
| 83.5.38 | FDCAN Tx buffer add request register (FDCAN_TXBAR) ..... | 4833 |
| 83.5.39 | FDCAN Tx buffer cancellation request register (FDCAN_TXBCR) .. | 4834 |
| 83.5.40 | FDCAN Tx buffer transmission occurred register (FDCAN_TXBTO) | 4834 |
| 83.5.41 | FDCAN Tx buffer cancellation finished register (FDCAN_TXBCF) .. | 4835 |
| 83.5.42 | FDCAN Tx buffer transmission interrupt enable register (FDCAN_TXBTIE) ..... | 4835 |
| 83.5.43 | FDCAN Tx buffer cancellation finished interrupt enable register (FDCAN_TXBCIE) ..... | 4836 |
| 83.5.44 | FDCAN Tx event FIFO configuration register (FDCAN_TXEFC) ... | 4836 |
| 83.5.45 | FDCAN Tx event FIFO status register (FDCAN_TXEFS) ..... | 4837 |
| 83.5.46 | FDCAN Tx event FIFO acknowledge register (FDCAN_TXEFA) ... | 4838 |
| 83.5.47 | FDCAN register map ..... | 4838 |
| 83.6 | TTCAN registers ..... | 4842 |
| 83.6.1 | FDCAN TT trigger memory configuration register (FDCAN_TTTMC) ..... | 4842 |
| 83.6.2 | FDCAN TT reference message configuration register (FDCAN_TTRMC) ..... | 4842 |
| 83.6.3 | FDCAN TT operation configuration register (FDCAN_TTOCF) ..... | 4843 |
| 83.6.4 | FDCAN TT matrix limits register (FDCAN_TTMLM) ..... | 4845 |
| 83.6.5 | FDCAN TUR configuration register (FDCAN_TURCF) ..... | 4846 |
| 83.6.6 | FDCAN TT operation control register (FDCAN_TTOCN) ..... | 4847 |
| 83.6.7 | FDCAN TT global time preset register (FDCAN_TTGTP) ..... | 4849 |
| 83.6.8 | FDCAN TT time mark register (FDCAN_TTTMK) ..... | 4849 |
| 83.6.9 | FDCAN TT interrupt register (FDCAN_TTIR) ..... | 4850 |
| 83.6.10 | FDCAN TT interrupt enable register (FDCAN_TTIE) ..... | 4852 |
| 83.6.11 | FDCAN TT interrupt line select register (FDCAN_TTILS) ..... | 4854 |
| 83.6.12 | FDCAN TT operation status register (FDCAN_TTOST) ..... | 4855 |
| 83.6.13 | FDCAN TUR numerator actual register (FDCAN_TURNA) ..... | 4857 |
| 83.6.14 | FDCAN TT local and global time register (FDCAN_TTLGT) ..... | 4858 |
| 83.6.15 | FDCAN TT cycle time and count register (FDCAN_TTCTC) ..... | 4858 |
| 83.6.16 | FDCAN TT capture time register (FDCAN_TTCPT) ..... | 4859 |
| 83.6.17 | FDCAN TT cycle sync mark register (FDCAN_TTCSM) ..... | 4859 |
| 83.6.18 | FDCAN TT trigger select register (FDCAN_TTTS) ..... | 4860 |
| 83.6.19 | FDCAN TT register map ..... | 4860 |
| 83.7 | CCU registers ..... | 4862 |
| 83.7.1 | Clock calibration unit core release register (FDCAN_CCU_CREL) .. | 4862 |
| 83.7.2 | Calibration configuration register (FDCAN_CCU_CCFG) ..... | 4862 |
| 83.7.3 | Calibration status register (FDCAN_CCU_CSTAT) ..... | 4864 |
| 83.7.4 | Calibration watchdog register (FDCAN_CCU_CWD) ..... | 4864 |
| 83.7.5 | Clock calibration unit interrupt register (FDCAN_CCU_IR) ..... | 4865 |
| 83.7.6 | Clock calibration unit interrupt enable register (FDCAN_CCU_IE) .. | 4866 |
| 83.7.7 | CCU register map ..... | 4866 |
| 84 | USB subsystem (USBSS) ..... | 4868 |
| 84.1 | Overview ..... | 4868 |
| 84.2 | USB2 host high-speed port (USBH + USB2PHY1) ..... | 4869 |
| 84.2.1 | USB2 host high-speed port main features ..... | 4869 |
| 84.2.2 | USB2 host high-speed port implementation ..... | 4869 |
| 84.2.3 | USB2 host high-speed port functional description ..... | 4870 |
| 84.2.4 | USB2 host high-speed port interrupts | 4873 |
| 84.2.5 | USB2 host high-speed port programmable parameters | 4873 |
| 84.2.6 | Connections to SYSCFG | 4874 |
| 84.3 | USB3 DRD port (USB3DR + USB2PHY2 + COMBOPHY) | 4876 |
| 84.3.1 | USB3 DRD (dual-role data) port main features | 4876 |
| 84.3.2 | USB3 DRD port functional description | 4878 |
| 84.3.3 | USB3 DRD port interrupts | 4881 |
| 84.3.4 | USB3 DRD port programmable parameters | 4882 |
| 84.3.5 | Connections to SYSCFG | 4886 |
| 84.4 | USB Type-C and power delivery interface | 4889 |
| 84.4.1 | USB Type-C and power delivery interface main features | 4889 |
| 84.4.2 | USB Type-C and power delivery interface implementation | 4890 |
| 84.4.3 | USB Type-C and power delivery interface functional description | 4891 |
| 84.4.4 | USB Type-C and power delivery interrupts | 4892 |
| 84.4.5 | Need for an ADC channel | 4893 |
| 85 | USB3 xHCI SuperSpeed dual role controller (USB3DR) | 4894 |
| 85.1 | Introduction | 4894 |
| 85.2 | USB3DR main features | 4894 |
| 85.3 | USB3DR functional description | 4895 |
| 85.3.1 | USB3DR block diagram | 4895 |
| 85.4 | USB3DR registers | 4896 |
| 85.4.1 | xHCI registers | 4896 |
| 85.4.2 | Global register block | 4897 |
| 85.4.3 | Device register block | 4967 |
| 85.4.4 | Battery charger register block | 4982 |
| 85.4.5 | Link register block | 4984 |
| 85.4.6 | USB3DR register map | 4987 |
| 86 | USB2 EHCI/OHCI high/full/low-speed host controller (USBH) | 4997 |
| 86.1 | Introduction | 4997 |
| 86.2 | USBH main features | 4997 |
| 86.3 | USBH functional description | 4998 |
| 86.3.1 | USBH block diagram | 4998 |
| 86.3.2 | Description of USBH packet buffer | 4998 |
| 86.3.3 | Description of USBH root hub | 4998 |
| 86.4 | USBH interrupts | 4999 |
| 86.5 | USBH registers | 4999 |
| 86.5.1 | USBH OHCI standard registers | 4999 |
| 86.5.2 | USBH OHCI implementation register #6 (USBH_OHCI_INSNREG06) | 5000 |
| 86.5.3 | USBH OHCI implementation register #7 (USBH_OHCI_INSNREG07) | 5001 |
| 86.5.4 | USBH EHCI standard registers | 5001 |
| 86.5.5 | USBH EHCI implementation register #1 (USBH_EHCI_INSNREG01) | 5002 |
| 86.5.6 | USBH EHCI implementation register #2 (USBH_EHCI_INSNREG02) | 5003 |
| 86.5.7 | USBH EHCI implementation register #3 (USBH_EHCI_INSNREG03) | 5003 |
| 86.5.8 | USBH EHCI implementation register #4 (USBH_EHCI_INSNREG04) | 5005 |
| 86.5.9 | USBH EHCI implementation register #5 (USBH_EHCI_INSNREG05) | 5006 |
| 86.5.10 | USBH EHCI implementation register #6 (USBH_EHCI_INSNREG06) | 5007 |
| 86.5.11 | USBH EHCI implementation register #7 (USBH_EHCI_INSNREG07) | 5007 |
| 86.5.12 | USBH register map | 5008 |
| 87 | USB Type-C®/USB Power Delivery interface (UCPD) | 5012 |
| 87.1 | Introduction | 5012 |
| 87.2 | UCPD main features | 5012 |
| 87.3 | UCPD implementation | 5013 |
| 87.4 | UCPD functional description | 5013 |
| 87.4.1 | UCPD block diagram | 5014 |
| 87.4.2 | UCPD reset and clocks | 5015 |
| 87.4.3 | Physical layer protocol | 5015 |
| 87.4.4 | UCPD BMC transmitter | 5022 |
| 87.4.5 | UCPD BMC receiver | 5023 |
| 87.4.6 | UCPD Type-C pull-ups (Rp) and pull-downs (Rd) | 5025 |
| 87.4.7 | UCPD Type-C voltage monitoring and de-bouncing | 5025 |
| 87.4.8 | UCPD DMA Interface | 5026 |
| 87.4.9 | Wake-up from Stop mode | 5026 |
| 87.5 | UCPD programming sequences | 5026 |
| 87.5.1 | Initialization phase ..... | 5026 |
| 87.5.2 | Type-C state machine handling ..... | 5026 |
| 87.5.3 | USB PD transmit ..... | 5028 |
| 87.5.4 | USB PD receive ..... | 5029 |
| 87.5.5 | UCPD software trimming ..... | 5030 |
| 87.6 | UCPD low-power modes ..... | 5030 |
| 87.7 | UCPD interrupts ..... | 5031 |
| 87.8 | UCPD registers ..... | 5032 |
| 87.8.1 | UCPD configuration register 1 (UCPD_CFGR1) ..... | 5032 |
| 87.8.2 | UCPD configuration register 2 (UCPD_CFGR2) ..... | 5034 |
| 87.8.3 | UCPD configuration register 3 (UCPD_CFGR3) ..... | 5034 |
| 87.8.4 | UCPD control register (UCPD_CR) ..... | 5035 |
| 87.8.5 | UCPD interrupt mask register (UCPD_IMR) ..... | 5037 |
| 87.8.6 | UCPD status register (UCPD_SR) ..... | 5039 |
| 87.8.7 | UCPD interrupt clear register (UCPD_ICR) ..... | 5042 |
| 87.8.8 | UCPD Tx ordered set type register (UCPD_TX_ORDSETR) ..... | 5043 |
| 87.8.9 | UCPD Tx payload size register (UCPD_TX_PAYSZR) ..... | 5043 |
| 87.8.10 | UCPD Tx data register (UCPD_TXDR) ..... | 5044 |
| 87.8.11 | UCPD Rx ordered set register (UCPD_RX_ORDSETR) ..... | 5044 |
| 87.8.12 | UCPD Rx payload size register (UCPD_RX_PAYSZR) ..... | 5045 |
| 87.8.13 | UCPD receive data register (UCPD_RXDR) ..... | 5046 |
| 87.8.14 | UCPD Rx ordered set extension register 1 (UCPD_RX_ORDEXTR1) ..... | 5046 |
| 87.8.15 | UCPD Rx ordered set extension register 2 (UCPD_RX_ORDEXTR2) ..... | 5047 |
| 87.8.16 | UCPD version register (UCPD_VERR) ..... | 5047 |
| 87.8.17 | UCPD identification register (UCPD_IPIDR) ..... | 5048 |
| 87.8.18 | UCPD size identification register (UCPD_SIDR) ..... | 5048 |
| 87.8.19 | UCPD register map ..... | 5048 |
| 88 | PCIE subsystem (PCIESS) ..... | 5051 |
| 88.1 | Introduction ..... | 5051 |
| 88.2 | Main features ..... | 5051 |
| 88.3 | Functional description ..... | 5052 |
| 88.3.1 | Block diagram ..... | 5052 |
| 88.3.2 | ePTM ..... | 5052 |
| 88.4 | PCIESS registers ..... | 5054 |
| 89 | PCIe® dual mode gen2 controller (PCIE) | 5055 |
| 89.1 | PCIe introduction | 5055 |
| 89.2 | PCIe main features | 5055 |
| 89.3 | PCIe functional description | 5056 |
| 89.3.1 | PCIe block diagram | 5056 |
| 90 | Combo PHY (COMBOPHY) | 5057 |
| 90.1 | Introduction | 5057 |
| 90.2 | COMBOPHY main features | 5057 |
| 90.3 | COMBOPHY functional description | 5058 |
| 90.3.1 | COMBOPHY block diagram | 5059 |
| 90.3.2 | COMBOPHY reference clock | 5059 |
| 90.4 | COMBOPHY registers | 5060 |
| 90.4.1 | COMBOPHY MPLL loop control register (COMBOPHY_MPLL_LOOP_CTL_CR) | 5060 |
| 90.4.2 | COMBOPHY register map | 5060 |
| 91 | Ethernet subsystem overview (ETHSS) | 5061 |
| 91.1 | Introduction | 5061 |
| 91.2 | ETHSS main features | 5061 |
| 91.3 | ETHSS functional description | 5061 |
| 91.3.1 | ETHSS block diagram | 5061 |
| 91.3.2 | ETHSS pins and internal signals | 5062 |
| 91.3.3 | ETHSS clocks | 5066 |
| 92 | Ethernet (ETH): gigabit media access control (GMAC) with DMA controller | 5067 |
| 92.1 | Ethernet introduction | 5067 |
| 92.2 | Ethernet main features | 5067 |
| 92.2.1 | Standard compliance | 5067 |
| 92.2.2 | MAC features | 5067 |
| 92.2.3 | Transaction layer (MTL) features | 5069 |
| 92.2.4 | DMA block features | 5070 |
| 92.2.5 | Bus interface features | 5071 |
| 92.2.6 | Audio and video features | 5072 |
| 92.2.7 | Time sensitive networking features | 5072 |
| 92.2.8 | Generic queuing features ..... | 5072 |
| 92.3 | Ethernet pins and internal signals ..... | 5072 |
| 92.4 | Ethernet architecture ..... | 5074 |
| 92.4.1 | DMA controller ..... | 5076 |
| 92.4.2 | MTL ..... | 5083 |
| 92.4.3 | MAC ..... | 5083 |
| 92.4.4 | Multiple channels and queues support ..... | 5088 |
| 92.5 | Ethernet functional description: MAC ..... | 5100 |
| 92.5.1 | Double VLAN processing ..... | 5100 |
| 92.5.2 | Source address and VLAN insertion, replacement, or deletion ..... | 5101 |
| 92.5.3 | Queue/channel-based VLAN tag insertion on Tx ..... | 5102 |
| 92.5.4 | Packet filtering ..... | 5103 |
| 92.5.5 | IEEE 1588 timestamp support ..... | 5115 |
| 92.5.6 | Time sensitive networking (TSN) ..... | 5141 |
| 92.5.7 | Checksum offload engine ..... | 5170 |
| 92.5.8 | TCP segmentation offload ..... | 5176 |
| 92.5.9 | IPv4 ARP offload ..... | 5182 |
| 92.5.10 | Loopback ..... | 5183 |
| 92.5.11 | Flow control ..... | 5184 |
| 92.5.12 | MAC management counters ..... | 5188 |
| 92.5.13 | Interrupts generated by the MAC ..... | 5191 |
| 92.5.14 | MAC and MMC register descriptions ..... | 5191 |
| 92.6 | Ethernet functional description: PHY interfaces ..... | 5192 |
| 92.6.1 | Station management agent (SMA) ..... | 5192 |
| 92.6.2 | Media independent interface (MII) ..... | 5199 |
| 92.6.3 | Reduced media independent interface (RMII) ..... | 5200 |
| 92.6.4 | Reduced gigabit media independent interface (RGMII) ..... | 5203 |
| 92.7 | Ethernet low-power modes ..... | 5206 |
| 92.7.1 | Low-power management ..... | 5206 |
| 92.7.2 | Energy Efficient Ethernet (EEE) ..... | 5212 |
| 92.8 | Ethernet interrupts ..... | 5218 |
| 92.8.1 | DMA interrupts ..... | 5218 |
| 92.8.2 | MTL interrupts ..... | 5219 |
| 92.8.3 | MAC Interrupts ..... | 5220 |
| 92.9 | Ethernet programming model ..... | 5221 |
| 92.9.1 | DMA initialization ..... | 5221 |
| 92.9.2 | MTL initialization | 5222 |
| 92.9.3 | MAC initialization | 5223 |
| 92.9.4 | Performing normal receive and transmit operation | 5223 |
| 92.9.5 | Stopping and starting transmission | 5224 |
| 92.9.6 | Programming guidelines for switching to new descriptor list in RxDMA | 5225 |
| 92.9.7 | Programming guidelines for switching the AXI clock frequency | 5225 |
| 92.9.8 | Programming guidelines for multichannel multiqueue operation | 5225 |
| 92.9.9 | Programming guidelines for GMII link state transitions | 5228 |
| 92.9.10 | Programming guidelines for IEEE 1588 timestamping | 5229 |
| 92.9.11 | Programming guidelines for PTP offload feature | 5230 |
| 92.9.12 | Programming guidelines for AV feature | 5234 |
| 92.9.13 | Programming guidelines for Energy Efficient Ethernet (EEE) | 5236 |
| 92.9.14 | Programming guidelines for flexible pulse-per-second (PPS) output | 5237 |
| 92.9.15 | Programming guidelines for IEEE 1588 auxiliary snapshot | 5240 |
| 92.9.16 | Programming guidelines for TSO | 5240 |
| 92.9.17 | Programming guidelines to perform VLAN filtering on the receiver | 5241 |
| 92.9.18 | Programming guidelines for extended VLAN filtering and routing on reception | 5242 |
| 92.9.19 | Programming sequence for queue/channel- based VLAN inclusion register | 5242 |
| 92.9.20 | Programming guidelines for EST | 5243 |
| 92.9.21 | Programming the launch time in time-based scheduling | 5245 |
| 92.9.22 | Enabling the frame preemption function | 5245 |
| 92.10 | Descriptors | 5246 |
| 92.10.1 | Descriptor overview | 5246 |
| 92.10.2 | Descriptor structure | 5247 |
| 92.10.3 | Transmit descriptor | 5250 |
| 92.10.4 | Receive descriptor | 5263 |
| 92.10.5 | Enhanced descriptor for time-based scheduling | 5276 |
| 92.11 | Ethernet registers | 5280 |
| 92.11.1 | Ethernet register maps | 5280 |
| 92.11.2 | Ethernet DMA registers | 5280 |
| 92.11.3 | Ethernet MTL registers | 5317 |
| 92.11.4 | Ethernet MAC and MMC registers | 5352 |
| 93 | Ethernet switch (ETHSW) | 5517 |
| 93.1 | Introduction | 5517 |
| 93.2 | ETHSW main features | 5517 |
| 93.3 | ETHSW functional description | 5517 |
| 93.3.1 | ETHSW block diagram | 5517 |
| 93.3.2 | ETHSW pins and internal signals | 5519 |
| 93.3.3 | ETHSW reset and clocks | 5521 |
| 93.3.4 | FES Ethernet switch | 5521 |
| 93.3.5 | FRTC | 5567 |
| 93.3.6 | FSC | 5567 |
| 93.3.7 | FPTS | 5571 |
| 93.3.8 | AC | 5572 |
| 93.3.9 | IBC | 5574 |
| 93.3.10 | AHB2Avalon | 5574 |
| 93.3.11 | Ethernet interface adapters (EIA) | 5577 |
| 93.3.12 | Bibliography | 5579 |
| 93.4 | ETHSW interrupts | 5580 |
| 93.5 | ETHSW registers | 5580 |
| 93.5.1 | ETHSW registers maps | 5580 |
| 93.5.2 | ETHSW AC registers | 5582 |
| 93.5.3 | ETHSW IBC registers | 5586 |
| 93.5.4 | ETHSW FTPS registers | 5591 |
| 93.5.5 | ETHSW FRTC registers | 5595 |
| 93.5.6 | ETHSW FSC registers | 5603 |
| 93.5.7 | ETHSW FES registers | 5616 |
| 93.5.8 | ETHSW EIA registers | 5702 |
| 93.5.9 | ETHSW register map | 5705 |
| 94 | Ethernet switch acceleration module (ETHSW_ACM) | 5734 |
| 94.1 | Introduction | 5734 |
| 94.2 | ETHSW_ACM main features | 5734 |
| 94.3 | ETHSW_ACM application example | 5735 |
| 94.4 | ETHSW_ACM functional description | 5736 |
| 94.4.1 | ETHSW_ACM block diagram | 5736 |
| 94.4.2 | ETHSW_ACM pins | 5738 |
| 94.4.3 | ETHSW_ACM clocks | 5738 |
| 94.4.4 | Frame format | 5738 |
| 94.4.5 | Bypass module overview | 5741 |
| 94.4.6 | Schedule module overview | 5742 |
| 94.4.7 | Redundancy functionality overview | 5743 |
| 94.5 | Bibliography | 5744 |
| 94.6 | ETHSW_ACM registers | 5745 |
| 95 | Hardware debug port (HDP) | 5746 |
| 95.1 | HDP main features | 5746 |
| 95.2 | Functional description | 5746 |
| 95.3 | HDP registers | 5748 |
| 95.3.1 | HDP control register (HDP_CTRL) | 5748 |
| 95.3.2 | HDP multiplexer control register (HDP_MUX) | 5748 |
| 95.3.3 | HDP read back value register (HDP_VAL) | 5749 |
| 95.3.4 | HDP general purpose output set register (HDP_GPOSET) | 5749 |
| 95.3.5 | HDP general purpose output clear register (HDP_GPOCLR) | 5749 |
| 95.3.6 | HDP general purpose output value register (HDP_GPOVAL) | 5750 |
| 95.3.7 | HDP version register (HDP_VERR) | 5750 |
| 95.3.8 | HDP identification register (HDP_IPIDR) | 5751 |
| 95.3.9 | HDP size identification register (HDP_SIDR) | 5751 |
| 95.3.10 | HDP register map | 5751 |
| 96 | Software error robustness collector (SERC) | 5753 |
| 96.1 | Introduction | 5753 |
| 96.2 | SERF main features | 5753 |
| 96.3 | SERF functional description | 5753 |
| 96.3.1 | SERF block diagram | 5753 |
| 96.3.2 | SERF key internal signals | 5755 |
| 96.3.3 | SERF resets and clocks | 5755 |
| 96.3.4 | Functionality and programming model | 5755 |
| 96.4 | SERF low-power modes | 5761 |
| 96.5 | SERC interrupts | 5761 |
| 96.6 | SERC registers | 5762 |
| 96.6.1 | SERC interrupt enable register 0 (SERC_IER0) | 5762 |
| 96.6.2 | SERC interrupt enable register 1 (SERC_IER1) | 5763 |
| 96.6.3 | SERC interrupt enable register 2 (SERC_IER2) | 5763 |
| 96.6.4 | SERC interrupt enable register 3 (SERC_IER3) | 5764 |
| 96.6.5 | SERC interrupt enable register 4 (SERC_IER4) | 5764 |
| 96.6.6 | SERC interrupt enable register 5 (SERC_IER5) . . . . . | 5764 |
| 96.6.7 | SERC interrupt status register 0 (SERC_ISR0) . . . . . | 5765 |
| 96.6.8 | SERC interrupt status register 1 (SERC_ISR1) . . . . . | 5765 |
| 96.6.9 | SERC interrupt status register 2 (SERC_ISR2) . . . . . | 5766 |
| 96.6.10 | SERC interrupt status register 3 (SERC_ISR3) . . . . . | 5766 |
| 96.6.11 | SERC interrupt status register 4 (SERC_ISR4) . . . . . | 5766 |
| 96.6.12 | SERC interrupt status register 5 (SERC_ISR5) . . . . . | 5767 |
| 96.6.13 | SERC interrupt clear register 0 (SERC_ICR0) . . . . . | 5767 |
| 96.6.14 | SERC interrupt clear register 1 (SERC_ICR1) . . . . . | 5768 |
| 96.6.15 | SERC interrupt clear register 2 (SERC_ICR2) . . . . . | 5768 |
| 96.6.16 | SERC interrupt clear register 3 (SERC_ICR3) . . . . . | 5768 |
| 96.6.17 | SERC interrupt clear register 4 (SERC_ICR4) . . . . . | 5769 |
| 96.6.18 | SERC interrupt clear register 5 (SERC_ICR5) . . . . . | 5769 |
| 96.6.19 | SERC enable (SERC_ENABLE) . . . . . | 5770 |
| 96.6.20 | SERC hardware configuration register (SERC_HWCFGR) . . . . . | 5770 |
| 96.6.21 | SERC version register (SERC_VERR) . . . . . | 5771 |
| 96.6.22 | SERC identification register (SERC_IPIDR) . . . . . | 5771 |
| 96.6.23 | SERC size identification register (SERC_SIDR) . . . . . | 5771 |
| 96.6.24 | SERC register map . . . . . | 5772 |
| 97 | Debug support (DBG) . . . . . | 5774 |
| 97.1 | DBG introduction . . . . . | 5774 |
| 97.2 | DBG use cases . . . . . | 5775 |
| 97.3 | DBG block diagram . . . . . | 5776 |
| 97.4 | DBG pins . . . . . | 5777 |
| 97.5 | DBG power and clocking . . . . . | 5777 |
| 97.5.1 | DBG power domains . . . . . | 5777 |
| 97.5.2 | DBG clocks . . . . . | 5778 |
| 97.5.3 | Debug and low-power modes . . . . . | 5779 |
| 97.5.4 | Debug reset . . . . . | 5779 |
| 97.6 | Security . . . . . | 5780 |
| 97.6.1 | Authentication signals . . . . . | 5780 |
| 97.7 | Chip-level TAP controller (CLTAPC) . . . . . | 5781 |
| 97.8 | Serial-wire and JTAG debug port (SWJ-DP) . . . . . | 5782 |
| 97.8.1 | JTAG debug port . . . . . | 5782 |
| 97.8.2 | SWD debug port . . . . . | 5783 |
| 97.9 | Access ports ..... | 5783 |
| 97.9.1 | Authentication ..... | 5784 |
| 97.10 | System debug features ..... | 5784 |
| 97.10.1 | System ROM tables ..... | 5785 |
| 97.10.2 | CoreSight global timestamp generator (TSGEN) ..... | 5788 |
| 97.10.3 | Cross trigger interface (CTI) and matrix (CTM) ..... | 5789 |
| 97.10.4 | Trace funnel (CSTF) ..... | 5797 |
| 97.10.5 | Embedded trace FIFO (ETF) ..... | 5797 |
| 97.10.6 | Embedded trace router (ETR) ..... | 5798 |
| 97.10.7 | Trace port interface unit (TPIU) ..... | 5799 |
| 97.10.8 | Replicator ..... | 5799 |
| 97.10.9 | Serial-wire output (SWO) ..... | 5800 |
| 97.10.10 | System trace macrocell (STM) ..... | 5800 |
| 97.10.11 | Microcontroller debug unit (DBGMCU) ..... | 5807 |
| 97.11 | Cortex-A35 debug features ..... | 5828 |
| 97.11.1 | Cortex-A35 debug unit ..... | 5828 |
| 97.11.2 | Cortex-A35 performance monitoring unit (PMU) ..... | 5828 |
| 97.11.3 | Embedded trace macrocell (ETM) ..... | 5829 |
| 97.11.4 | Cross trigger interface (CTI) ..... | 5829 |
| 97.12 | Cortex-M33 debug features ..... | 5830 |
| 97.12.1 | ROM tables ..... | 5830 |
| 97.12.2 | Data watchpoint and trace unit (DWT) ..... | 5831 |
| 97.12.3 | Instrumentation trace macrocell (ITM) ..... | 5832 |
| 97.12.4 | Breakpoint unit (FPB) ..... | 5833 |
| 97.12.5 | Embedded trace macrocell (ETM) ..... | 5833 |
| 97.12.6 | Cross trigger interface (CTI) ..... | 5833 |
| 97.13 | Cortex-M0+ debug features ..... | 5833 |
| 97.13.1 | Single-wire debug interface ..... | 5833 |
| 97.13.2 | ROM tables ..... | 5834 |
| 97.13.3 | Data watchpoint and trace unit (DWT) ..... | 5835 |
| 97.13.4 | Breakpoint unit (BPU) ..... | 5835 |
| 97.13.5 | Cross trigger interface (CTI) ..... | 5835 |
| 97.14 | References ..... | 5836 |
| 98 | Device electronic signature ..... | 5837 |
| 98.1 | Unique device ID register (96 bits) (UID) ..... | 5837 |
| 98.2 | Device part number (RPN) ..... | 5838 |
| 98.3 | Device version ..... | 5839 |
| 98.4 | Package data register (PKG) ..... | 5840 |
| 99 | Important security notice ..... | 5841 |
| 100 | Revision history ..... | 5842 |
List of tables
| Table 1. | STNoC routing of the DDR traffic . . . . . | 215 |
| Table 2. | Connectivity matrix . . . . . | 217 |
| Table 3. | STNoC master port main characteristics . . . . . | 222 |
| Table 4. | Slave port main characteristics . . . . . | 223 |
| Table 5. | MLAHB400 master port main characteristics . . . . . | 225 |
| Table 6. | MLAHB400 target port main characteristics . . . . . | 226 |
| Table 7. | MLAHB200 master port main characteristics . . . . . | 226 |
| Table 8. | MLAHB200 slave ports main characteristics . . . . . | 227 |
| Table 9. | Register boundary addresses for Cortex-A35 (CPU1) and Cortex-M33 (CPU2) . . . . . | 230 |
| Table 10. | Register boundary addresses for Cortex-M0+ (CPU3) . . . . . | 249 |
| Table 11. | Cortex-A35 subsystem configuration . . . . . | 251 |
| Table 12. | Cortex-A35 subsystem reset sources . . . . . | 252 |
| Table 13. | CA35SS SYSCFG register map and reset value . . . . . | 263 |
| Table 14. | Mapping SSC registers to secure flag register . . . . . | 266 |
| Table 15. | CA35SS SSC register map and reset value . . . . . | 273 |
| Table 16. | GICV2M register map and reset values . . . . . | 277 |
| Table 17. | Cortex-M33 reset sources . . . . . | 280 |
| Table 18. | IDAU partitioning . . . . . | 282 |
| Table 19. | Memory partitioning . . . . . | 283 |
| Table 20. | Overview of RIF core components . . . . . | 289 |
| Table 21. | Interrupt connection types . . . . . | 293 |
| Table 22. | Access-type definitions for Arm TrustZone cores . . . . . | 293 |
| Table 23. | RIF illegal access definitions (security) . . . . . | 293 |
| Table 24. | RIF illegal access definitions (privilege) . . . . . | 294 |
| Table 25. | RIF illegal access definitions (compartments) . . . . . | 294 |
| Table 26. | BSEC internal input/output signals . . . . . | 300 |
| Table 27. | BSEC resets . . . . . | 301 |
| Table 28. | BSEC initial status reporting structure . . . . . | 305 |
| Table 29. | BSEC ad-hoc error/status reporting structure . . . . . | 306 |
| Table 30. | BSEC states definition . . . . . | 307 |
| Table 31. | Debug and trace profiles . . . . . | 310 |
| Table 32. | BSEC register map and reset values . . . . . | 326 |
| Table 33. | STM32MP23/25xx OTP mapping . . . . . | 329 |
| Table 34. | STM32MP23/25xx OTP fuse description (lower OTP region) . . . . . | 334 |
| Table 35. | STM32MP23/25xx OTP fuse description (mid OTP region) . . . . . | 343 |
| Table 36. | STM32MP23/25xx OTP fuse description (upper OTP region) . . . . . | 344 |
| Table 37. | RIMU resource assignment . . . . . | 347 |
| Table 38. | Indexes for non-RIF-aware peripherals (RISUP) . . . . . | 348 |
| Table 39. | Indexes for RIF-aware peripherals (with RCC control index) . . . . . | 349 |
| Table 40. | RISAL resource assignment (SmartRun domain) . . . . . | 350 |
| Table 41. | RIMU internal input/output signal . . . . . | 353 |
| Table 42. | RISUP internal input/output signals . . . . . | 353 |
| Table 43. | RISAL internal input/output signals . . . . . | 353 |
| Table 44. | DAP compartment ID allocation . . . . . | 354 |
| Table 45. | RIFSC register map and reset values . . . . . | 372 |
| Table 46. | RISAB resource assignment . . . . . | 375 |
| Table 47. | RISAB internal input/output signals . . . . . | 376 |
| Table 48. | RISAB register map and reset values. .... | 390 |
| Table 49. | RISAF resource assignment. .... | 393 |
| Table 50. | RISAF internal input/output signals. .... | 394 |
| Table 51. | RISAF subregion security setup matrix. .... | 396 |
| Table 52. | RISAF register map and reset values. .... | 416 |
| Table 53. | IAC internal signals. .... | 420 |
| Table 54. | IAC interrupt request. .... | 421 |
| Table 55. | IAC register map and reset values. .... | 425 |
| Table 56. | Frequency values for the DDRSS clocks versus data rate versus DDR JEDEC standard. .... | 428 |
| Table 57. | List of observable signals sent directly to HDP. .... | 432 |
| Table 58. | List of observable signals selectable and sent to HDP. .... | 433 |
| Table 59. | Detailed AC swizzling register values. .... | 441 |
| Table 60. | DDRSS register map and reset values. .... | 445 |
| Table 61. | DDRCTRL register map and reset values. .... | 552 |
| Table 62. | Function of DDRPHYC pins versus DDR protocol. .... | 571 |
| Table 63. | DDRPHYC register map and reset values. .... | 703 |
| Table 64. | Signals coming from DFI command-address decoder. .... | 742 |
| Table 65. | Signals monitored at performance logging interface (provided by DDRCTRL). .... | 743 |
| Table 66. | Events generated by the DFI command address decoder. .... | 745 |
| Table 67. | Filtering policy. .... | 750 |
| Table 68. | DDRPERFM register map and reset values. .... | 756 |
| Table 69. | Internal SRAM features. .... | 759 |
| Table 70. | Internal SRAM hardware erase feature. .... | 759 |
| Table 71. | Effect of low-power modes on RAMCFG. .... | 762 |
| Table 72. | RAMCFG interrupt requests. .... | 762 |
| Table 73. | RAMCFG register map and reset values. .... | 788 |
| Table 74. | ICACHE features. .... | 794 |
| Table 75. | TAG memory dimensioning parameters for n-way set associative operating mode (default). .... | 796 |
| Table 76. | TAG memory dimensioning parameters for direct-mapped cache mode. .... | 797 |
| Table 77. | ICACHE cacheability for AHB transaction. .... | 799 |
| Table 78. | Memory configurations. .... | 799 |
| Table 79. | ICACHE remap region size, base address and remap address. .... | 800 |
| Table 80. | ICACHE interrupts. .... | 804 |
| Table 81. | ICACHE register map and reset values. .... | 812 |
| Table 82. | DCACHE features. .... | 815 |
| Table 83. | TAG memory dimensioning parameters. .... | 818 |
| Table 84. | DCACHE cacheability for AHB transaction. .... | 820 |
| Table 85. | DCACHE interrupts. .... | 825 |
| Table 86. | DCACHE register map and reset values. .... | 833 |
| Table 87. | PWR pin overview. .... | 837 |
| Table 88. | \(V_{DDCPU}/V_{DDGPU}/V_{DDCORE}\) voltage levels (for reference only). .... | 840 |
| Table 89. | Available functions in backup domain. .... | 850 |
| Table 90. | CPU1 low-power mode summary. .... | 866 |
| Table 91. | CPU2 low-power mode summary. .... | 867 |
| Table 92. | CPU3 low-power mode summary. .... | 867 |
| Table 93. | System low-power modes. .... | 868 |
| Table 94. | Functionalities depending on system operating mode. .... | 869 |
| Table 95. | External regulators control. .... | 873 |
| Table 96. | PDD low-power mode control. .... | 874 |
| Table 97. | Low-power mode exit flags. .... | 876 |
| Table 98. | CPU1 CSleep mode | 881 |
| Table 99. | CPU2 CSleep mode | 881 |
| Table 100. | CPU3 CSleep mode | 882 |
| Table 101. | CPU1 CStop mode | 883 |
| Table 102. | CPU2 CStop mode | 883 |
| Table 103. | CPU3 CStop mode | 883 |
| Table 104. | D1 DStop1 mode | 884 |
| Table 105. | D1 DStandby mode | 885 |
| Table 106. | Stop1 mode | 886 |
| Table 107. | Stop2 mode | 887 |
| Table 108. | LP-Stop1 mode | 888 |
| Table 109. | LPLV-Stop1 mode | 888 |
| Table 110. | LP-Stop2 mode | 889 |
| Table 111. | LPLV-Stop2 mode | 889 |
| Table 112. | CPU1_HW_BEN and CPU2_HW_BEN management | 890 |
| Table 113. | Standby1 mode | 891 |
| Table 114. | Standby2 mode | 892 |
| Table 115. | VBAT modes | 893 |
| Table 116. | VBAT modes exit flags | 894 |
| Table 117. | PWR status flags | 896 |
| Table 118. | PWR register allocation to RIF resource and access conditions | 899 |
| Table 119. | PWR register map and reset values | 937 |
| Table 120. | Pin overview | 943 |
| Table 121. | IWDG timeout event combinations when TDCID = CPU1 | 947 |
| Table 122. | IWDG timeout event combinations when TDCID = CPU2 | 947 |
| Table 123. | Reset coverage summary | 951 |
| Table 124. | RCC registers with specific reset and specific voltages | 953 |
| Table 125. | RCC HWRSTSCLRR, RCC_C1HWRSTSCLRR, RCC_C2HWRSTSCLRR flags | 956 |
| Table 126. | First CPUx boot selection | 959 |
| Table 127. | HOLD_BOOT state control after system Standby exit | 961 |
| Table 128. | Oscillator states versus system modes | 966 |
| Table 129. | Root clock mapping | 984 |
| Table 130. | APB root clock mapping | 986 |
| Table 131. | HSI, MSI and HSE states versus system modes | 989 |
| Table 132. | Resources blocked during clock restore sequence | 994 |
| Table 133. | Kernel clock distribution overview | 996 |
| Table 134. | Ratio between clock timers and ck_icn_apbx | 999 |
| Table 135. | ADC kernel clock source selection | 1000 |
| Table 136. | Gating control of the APB clocks with ck_in_p_ddrc and ck_in_p_ddrphyc | 1002 |
| Table 137. | Gating control of ck_icn_s_ddr clock | 1003 |
| Table 138. | DDRCKMOD control description | 1003 |
| Table 139. | DDRC low-power states description | 1004 |
| Table 140. | Recommended configurations when DDR is not shared (DDRSHR = 0) | 1009 |
| Table 141. | Recommended configurations when DDR is shared (DDRSHR = 1) | 1009 |
| Table 142. | MCDCG control bit when DDR is not shared (DDRSHR = 0) | 1010 |
| Table 143. | MCDCG control bit when DDR is shared (DDRSHR = 1) | 1011 |
| Table 144. | DPHYCG control bit when DDR is not shared (DDRSHR = 0) | 1011 |
| Table 145. | DPHYCG control bit when DDR is shared (DDRSHR = 1) | 1012 |
| Table 146. | Shareable peripherals list | 1014 |
| Table 147. | Peripheral bus clock enabling logic | 1017 |
| Table 148. | Peripheral kernel clock enabling logic | 1019 |
| Table 149. | CPU1 mode details | 1021 |
| Table 150. | Bus clock enable details for ck_icn_ahbx with x = 2,5,6 and ck_icn_apby with y = 1,2,3,4,dbg. .... | 1023 |
| Table 151. | Bus clock enable details for ck_icn_sdmmc, ck_icn_ddr, ck_icn_display, ck_icn_hsl, ck_icn_nic, ck_icn_vid, ck_icn_ahb3, ck_icn_ahbsr, and ck_icn_ahb4. .... | 1024 |
| Table 152. | Bus clock enable details for ck_icn_hs_mcu, ck_icn_ls_mcu, ck_icn_hs_mlahb and ck_icn_ls_mlahb .... | 1025 |
| Table 153. | FMC interface clocks from RCC .... | 1030 |
| Table 154. | Octo-SPI interface clocks from RCC .... | 1031 |
| Table 155. | Octo-SPI interface clocks from DLYBOS1 and DLYBOS2 .... | 1032 |
| Table 156. | SDMMC interface clocks from RCC .... | 1033 |
| Table 157. | SDMMC interface clocks from DLYBSD1/2/3. .... | 1034 |
| Table 158. | Ethernet clocks from RCC .... | 1037 |
| Table 159. | Ethernet clocks to/from I/Os .... | 1037 |
| Table 160. | Active I/O per mode (MII, RMII, RGMII) .... | 1038 |
| Table 161. | Ethernet MAC speed encoding. .... | 1040 |
| Table 162. | PCIE clocks from RCC .... | 1041 |
| Table 163. | PCIE clocks from HSE .... | 1041 |
| Table 164. | PCIE clocks from I/Os. .... | 1042 |
| Table 165. | COMBOPHY register programming - Reference clock. .... | 1043 |
| Table 166. | COMBOPHY register programming - SSC control. .... | 1043 |
| Table 167. | Cortex-A35 subsystem clocks from RCC .... | 1044 |
| Table 168. | Camera subsystem external clocks .... | 1045 |
| Table 169. | Camera subsystem internal clocks. .... | 1046 |
| Table 170. | Display subsystem external clocks. .... | 1047 |
| Table 171. | Display subsystem internal clocks. .... | 1048 |
| Table 172. | DPHY_PLL_X4TX internal clocks. .... | 1050 |
| Table 173. | VENC and VDEC subsystem clocks. .... | 1052 |
| Table 174. | GPU and NPU subsystem clocks. .... | 1053 |
| Table 175. | USB2 host port clocks from RCC and oscillator. .... | 1055 |
| Table 176. | USB2 host port clocks from USB2PHY1. .... | 1056 |
| Table 177. | USB3 DRD port clocks from RCC and oscillator. .... | 1057 |
| Table 178. | USB3 DRD port clocks from USB2PHY2 and USB3 PCIE COMBOPHY. .... | 1058 |
| Table 179. | USB3 PCIE COMBOPHY PLL control bits according to reference clock frequency. .... | 1059 |
| Table 180. | Spread-spectrum range. .... | 1059 |
| Table 181. | UCPD clocks from RCC. .... | 1060 |
| Table 182. | Interrupt sources and control. .... | 1063 |
| Table 183. | RCC register allocation to RIF resource and access conditions. .... | 1069 |
| Table 184. | RCC register map and reset values. .... | 1284 |
| Table 185. | HSEM internal input/output signals. .... | 1307 |
| Table 186. | Semaphore CID filtering. .... | 1313 |
| Table 187. | Semaphore attributes. .... | 1314 |
| Table 188. | Authorized bus master IDs. .... | 1315 |
| Table 189. | HSEM register map and reset values. .... | 1337 |
| Table 190. | IPCC features implementation. .... | 1342 |
| Table 191. | IPCC interface signals. .... | 1343 |
| Table 192. | Bits used for the communication. .... | 1344 |
| Table 193. | IPCC security modes. .... | 1350 |
| Table 194. | Access to channels. .... | 1351 |
| Table 195. | IPCC register map and reset values. .... | 1366 |
| Table 196. | Port x bit configurations. .... | 1369 |
| Table 197. | Secure AF between peripherals and allocated I/Os. .... | 1376 |
| Table 198. | GPIO protected bits . . . . . | 1377 |
| Table 199. | GPIO register map and reset values . . . . . | 1402 |
| Table 200. | SYSCFG register map and reset values. . . . . | 1477 |
| Table 201. | Peripherals interconnect matrix . . . . . | 1493 |
| Table 202. | Peripherals interconnect matrix details. . . . . | 1496 |
| Table 203. | Implementation of HPDMA1/2/3 channels . . . . . | 1519 |
| Table 204. | HPDMA1/2/3 autonomous mode and wake-up in low-power modes . . . . . | 1519 |
| Table 205. | Programmed HPDMA1/2/3 request . . . . . | 1520 |
| Table 206. | Programmed HPDMA1/2/3 request as a block request . . . . . | 1525 |
| Table 207. | HPDMA channel with peripheral early termination . . . . . | 1525 |
| Table 208. | Programmed HPDMA1/2/3 request with peripheral early termination . . . . . | 1526 |
| Table 209. | Programmed HPDMA1/2/3 trigger . . . . . | 1526 |
| Table 210. | Programmed HPDMA source/destination burst . . . . . | 1549 |
| Table 211. | Programmed data handling . . . . . | 1554 |
| Table 212. | Effect of low-power modes on HPDMA . . . . . | 1578 |
| Table 213. | HPDMA interrupt requests . . . . . | 1578 |
| Table 214. | HPDMA register map and reset values . . . . . | 1630 |
| Table 215. | LPDMA1 channels implementation. . . . . | 1635 |
| Table 216. | LPDMA1 autonomous mode and wake-up in low-power modes . . . . . | 1636 |
| Table 217. | Programmed LPDMA1 request. . . . . | 1636 |
| Table 218. | Programmed LPDMA1 request as a block request . . . . . | 1637 |
| Table 219. | LPDMA channel with peripheral early termination . . . . . | 1637 |
| Table 220. | Programmed LPDMA request with peripheral early termination. . . . . | 1637 |
| Table 221. | Programmed LPDMA1 trigger . . . . . | 1637 |
| Table 222. | Programmed LPDMA source/destination single. . . . . | 1657 |
| Table 223. | Programmed data handling . . . . . | 1658 |
| Table 224. | Effect of low-power modes on LPDMA. . . . . | 1671 |
| Table 225. | LPDMA interrupt requests . . . . . | 1671 |
| Table 226. | LPDMA register map and reset values. . . . . | 1710 |
| Table 227. | GPU register map and reset values . . . . . | 1729 |
| Table 228. | interrupt mapping for Cortex-M33. . . . . | 1735 |
| Table 229. | interrupt mapping for Cortex-M0+. . . . . | 1744 |
| Table 230. | Interrupt mapping for Cortex-A35 . . . . . | 1746 |
| Table 231. | GICD register map and reset values . . . . . | 1779 |
| Table 232. | GICC register map and reset values . . . . . | 1790 |
| Table 233. | GICH register map and reset values . . . . . | 1796 |
| Table 234. | GICV register map and reset values. . . . . | 1804 |
| Table 235. | EXTI implementation . . . . . | 1808 |
| Table 236. | EXTI signals . . . . . | 1809 |
| Table 237. | EVG signals . . . . . | 1810 |
| Table 238. | EXTI1 wake-up interrupts . . . . . | 1811 |
| Table 239. | EXTI2 wake-up interrupts . . . . . | 1814 |
| Table 240. | EXTI event input configurations and register control . . . . . | 1817 |
| Table 241. | Masking functionality . . . . . | 1819 |
| Table 242. | Register protection overview . . . . . | 1820 |
| Table 243. | Register protection hierarchy overview. . . . . | 1822 |
| Table 244. | EXTIx register map sections. . . . . | 1822 |
| Table 245. | EXTI1 register map and reset values . . . . . | 1910 |
| Table 246. | EXTI2 register map and reset values . . . . . | 1914 |
| Table 247. | CRC internal input/output signals . . . . . | 1920 |
| Table 248. | CRC register map and reset values . . . . . | 1926 |
| Table 249. | FMC interface interrupts . . . . . | 1930 |
| Table 250. | 256-Mbyte allocation between OCTOSPI1 and OCTOSPI2. .... | 1933 |
| Table 251. | RX and TX delays in lock mode ..... | 1936 |
| Table 252. | Number of delay elements enabled in each delay unit. .... | 1936 |
| Table 253. | Octo-SPI interface interrupts ..... | 1937 |
| Table 254. | OCTOSPI1 CS mapping when MUXEN = 0 and MODE = 0 ..... | 1937 |
| Table 255. | OCTOSPI2 CS mapping when MUXEN = 0 and MODE = 0 ..... | 1937 |
| Table 256. | OCTOSPI1 CS mapping when MUXEN = 0 and MODE = 1 ..... | 1938 |
| Table 257. | OCTOSPI2 CS mapping when MUXEN = 0 and MODE = 1 ..... | 1938 |
| Table 258. | OCTOSPI CS mapping when MUXEN = 1 and MODE = 0 ..... | 1939 |
| Table 259. | OCTOSPI CS mapping when MUXEN = 1 and MODE = 1 ..... | 1940 |
| Table 260. | DLYBOS1 SYSCFG bits. .... | 1942 |
| Table 261. | DLYBOS2 SYSCFG bits. .... | 1943 |
| Table 262. | OCTOSPI modes and recommended clock configuration ..... | 1944 |
| Table 263. | SD/e•MMC interface interrupts ..... | 1950 |
| Table 264. | DLYBSD1 SYSCFG bits. .... | 1950 |
| Table 265. | DLYBSD2 SYSCFG bits. .... | 1951 |
| Table 266. | DLYBSD3 SYSCFG bits. .... | 1952 |
| Table 267. | SD speed modes and recommended clock configuration ..... | 1952 |
| Table 268. | e•MMC Speed modes and recommended clock configuration. .... | 1953 |
| Table 269. | FMC features ..... | 1956 |
| Table 270. | FMC internal signals. .... | 1957 |
| Table 271. | FMC memory regions (default mapping) ..... | 1959 |
| Table 272. | NOR/PSRAM subregion selection ..... | 1959 |
| Table 273. | NOR/PSRAM External memory address ..... | 1960 |
| Table 274. | NAND access memory map ..... | 1960 |
| Table 275. | FMC RIF register properties and definitions. .... | 1962 |
| Table 276. | Programmable NOR/PSRAM access parameters ..... | 1971 |
| Table 277. | Non-multiplexed I/O NOR flash memory. .... | 1971 |
| Table 278. | 16-bit multiplexed I/O NOR flash memory ..... | 1972 |
| Table 279. | Non-multiplexed I/Os PSRAM/SRAM. .... | 1972 |
| Table 280. | 16-bit multiplexed I/O PSRAM ..... | 1972 |
| Table 281. | NOR flash/PSRAM: Example of supported memories and transactions ..... | 1973 |
| Table 282. | FMC_BCRx bitfields (mode 1) ..... | 1977 |
| Table 283. | FMC_BTRx bitfields (mode 1) ..... | 1977 |
| Table 284. | FMC_BCRx bitfields (mode A) ..... | 1979 |
| Table 285. | FMC_BTRx bitfields (mode A) ..... | 1980 |
| Table 286. | FMC_BWTRx bitfields (mode A) ..... | 1980 |
| Table 287. | FMC_BCRx bitfields (mode 2/B) ..... | 1982 |
| Table 288. | FMC_BTRx bitfields (mode 2/B) ..... | 1983 |
| Table 289. | FMC_BWTRx bitfields (mode 2/B) ..... | 1983 |
| Table 290. | FMC_BCRx bitfields (mode C) ..... | 1985 |
| Table 291. | FMC_BTRx bitfields (mode C) ..... | 1985 |
| Table 292. | FMC_BWTRx bitfields (mode C) ..... | 1986 |
| Table 293. | FMC_BCRx bitfields (mode D) ..... | 1987 |
| Table 294. | FMC_BTRx bitfields (mode D) ..... | 1988 |
| Table 295. | FMC_BWTRx bitfields (mode D) ..... | 1988 |
| Table 296. | FMC_BCRx bitfields (muxed mode) ..... | 1990 |
| Table 297. | FMC_BTRx bitfields (muxed mode) ..... | 1991 |
| Table 298. | FMC_BCRx bitfields (Synchronous multiplexed read mode) ..... | 1996 |
| Table 299. | FMC_BTRx bitfields (Synchronous multiplexed read mode) ..... | 1997 |
| Table 300. | FMC_BCRx bitfields (Synchronous multiplexed write mode) ..... | 1998 |
| Table 301. | FMC_BTRx bitfields (Synchronous multiplexed write mode) ..... | 1999 |
| Table 302. | Programmable NAND flash access parameters . . . . . | 2013 |
| Table 303. | 8-bit NAND flash memory . . . . . | 2014 |
| Table 304. | 16-bit NAND flash memory . . . . . | 2014 |
| Table 305. | Supported memories and transactions . . . . . | 2015 |
| Table 306. | Number of ECC parity bytes per sector . . . . . | 2020 |
| Table 307. | FMC NAND controller Interrupt request . . . . . | 2028 |
| Table 308. | HPR relevant bits . . . . . | 2034 |
| Table 309. | ECC result relevant bits . . . . . | 2035 |
| Table 310. | FMC register map . . . . . | 2053 |
| Table 311. | OCTOSPI implementation . . . . . | 2059 |
| Table 312. | OCTOSPI input/output pins . . . . . | 2061 |
| Table 313. | OCTOSPI internal signals . . . . . | 2061 |
| Table 314. | Command/address phase description . . . . . | 2070 |
| Table 315. | OctaRAM command address bit assignment (based on 64-Mbyte OctaRAM) . . . . . | 2081 |
| Table 316. | Address alignment cases . . . . . | 2088 |
| Table 317. | OCTOSPI interrupt requests . . . . . | 2089 |
| Table 318. | OCTOSPI register map and reset values . . . . . | 2114 |
| Table 319. | OCTOSPIM implementation . . . . . | 2118 |
| Table 320. | OCTOSPIM input/output pins . . . . . | 2119 |
| Table 321. | Use cases . . . . . | 2120 |
| Table 322. | OCTOSPIM register map and reset values . . . . . | 2128 |
| Table 323. | SDMMC features . . . . . | 2130 |
| Table 324. | SDMMC operation modes SD and SDIO . . . . . | 2133 |
| Table 325. | SDMMC operation modes eMMC . . . . . | 2133 |
| Table 326. | SDMMC internal input/output signals . . . . . | 2134 |
| Table 327. | SDMMC pins . . . . . | 2135 |
| Table 328. | SDMMC Command and data phase selection . . . . . | 2136 |
| Table 329. | Command token format . . . . . | 2142 |
| Table 330. | Short response with CRC token format . . . . . | 2143 |
| Table 331. | Short response without CRC token format . . . . . | 2143 |
| Table 332. | Long response with CRC token format . . . . . | 2143 |
| Table 333. | Specific Commands overview . . . . . | 2144 |
| Table 334. | Command path status flags . . . . . | 2145 |
| Table 335. | Command path error handling . . . . . | 2145 |
| Table 336. | Data token format . . . . . | 2153 |
| Table 337. | Data path status flags and clear bits . . . . . | 2153 |
| Table 338. | Data path error handling . . . . . | 2155 |
| Table 339. | Data FIFO access . . . . . | 2156 |
| Table 340. | Transmit FIFO status flags . . . . . | 2157 |
| Table 341. | Receive FIFO status flags . . . . . | 2159 |
| Table 342. | AHB and SDMMC_CK clock frequency relation . . . . . | 2163 |
| Table 343. | SDIO special operation control . . . . . | 2164 |
| Table 344. | 4-bit mode Start, interrupt, and CRC-status Signaling detection . . . . . | 2168 |
| Table 345. | CMD12 use cases . . . . . | 2173 |
| Table 346. | Data block gap hardware flow control behavior . . . . . | 2185 |
| Table 347. | Hardware flow control selection . . . . . | 2185 |
| Table 348. | SDMMC interrupts . . . . . | 2189 |
| Table 349. | Response type and SDMMC_RESPxR registers . . . . . | 2196 |
| Table 350. | SDMMC register map . . . . . | 2214 |
| Table 351. | STM32MP23/25xx features . . . . . | 2217 |
| Table 352. | DLYB functional signals . . . . . | 2219 |
| Table 353. | SDMMC DLYB interconnections. .... | 2220 |
| Table 354. | OCTOSPI DLYB interconnections. .... | 2220 |
| Table 355. | ADC features. .... | 2225 |
| Table 356. | ADC input/output pins. .... | 2227 |
| Table 357. | ADC internal input/output signals. .... | 2227 |
| Table 358. | ADC1/2 interconnection. .... | 2227 |
| Table 359. | ADC3 interconnection. .... | 2230 |
| Table 360. | Configuring the trigger polarity for regular external triggers. .... | 2249 |
| Table 361. | Configuring the trigger polarity for injected external triggers. .... | 2250 |
| Table 362. | TSAR timings depending on resolution. .... | 2254 |
| Table 363. | Offset computation versus data resolution. .... | 2258 |
| Table 364. | 12-bit data formats. .... | 2260 |
| Table 365. | Numerical examples for 32-bit or 16-bit format. .... | 2261 |
| Table 366. | Analog watchdog channel selection. .... | 2271 |
| Table 367. | Analog watchdog 1, 2, 3 comparison. .... | 2272 |
| Table 368. | Maximum output results versus N and M. .... | 2276 |
| Table 369. | Oversampler operating mode summary. .... | 2280 |
| Table 370. | DELAY bits versus ADC resolution. .... | 2281 |
| Table 371. | ADC interrupts. .... | 2284 |
| Table 372. | ADC register map and reset values for each ADC. .... | 2320 |
| Table 373. | ADC register map and reset values (master and slave ADC common registers). .... | 2323 |
| Table 374. | DTS internal input/output signals. .... | 2325 |
| Table 375. | SDA slave registers. .... | 2330 |
| Table 376. | SDA TS control register (SDATS_CR). .... | 2330 |
| Table 377. | SDA TS configuration register (SDATS_CFGR). .... | 2331 |
| Table 378. | SDA TS data register (SDATS_DR). .... | 2333 |
| Table 379. | SDA TS timer register (SDATS_TIMERR). .... | 2333 |
| Table 380. | Output resolution configuration. .... | 2339 |
| Table 381. | DTS interrupts. .... | 2340 |
| Table 382. | DTS register memory map. .... | 2341 |
| Table 383. | PVT common register map and reset values. .... | 2358 |
| Table 384. | PVT IRQ register map and reset values. .... | 2358 |
| Table 385. | DTS TSC clock synthesizer register map and reset values. .... | 2359 |
| Table 386. | DTS TS individual register map and reset values. .... | 2361 |
| Table 387. | VREFBUF typical values. .... | 2363 |
| Table 388. | VREF buffer modes. .... | 2364 |
| Table 389. | VREFBUF register map and reset values. .... | 2367 |
| Table 390. | MDF features. .... | 2369 |
| Table 391. | MDF external pins. .... | 2371 |
| Table 392. | MDF internal signals. .... | 2372 |
| Table 393. | MDF trigger connections. .... | 2372 |
| Table 394. | MDF break connections. .... | 2373 |
| Table 395. | MDF ADC data connections. .... | 2373 |
| Table 396. | Control of the common clock generation. .... | 2380 |
| Table 397. | Clock constraints with respect to the incoming stream. .... | 2381 |
| Table 398. | Data size according to CIC order and CIC decimation values. .... | 2388 |
| Table 399. | Maximum decimation ratio versus order and input data size. .... | 2389 |
| Table 400. | Possible gain values. .... | 2390 |
| Table 401. | Recommended maximum gain values versus CIC decimation ratios. .... | 2392 |
| Table 402. | Most common microphone settings. .... | 2392 |
| Table 403. | HPF 3 dB cut-off frequencies examples. .... | 2394 |
| Table 404. | Register protection summary . . . . . | 2415 |
| Table 405. | Effect of low-power modes on MDF . . . . . | 2416 |
| Table 406. | MDF interrupt requests . . . . . | 2418 |
| Table 407. | Examples of MDF settings for microphone capture . . . . . | 2419 |
| Table 408. | Programming sequence . . . . . | 2419 |
| Table 409. | Output signal levels . . . . . | 2426 |
| Table 410. | MDF register map and reset values . . . . . | 2452 |
| Table 411. | ADF features . . . . . | 2456 |
| Table 412. | ADF external pins . . . . . | 2457 |
| Table 413. | ADF internal signals . . . . . | 2457 |
| Table 414. | ADF trigger connections . . . . . | 2458 |
| Table 415. | Control of the common clock generation . . . . . | 2464 |
| Table 416. | Clock constraints with respect to the incoming stream . . . . . | 2465 |
| Table 417. | Data size according to CIC order and CIC decimation values . . . . . | 2470 |
| Table 418. | Possible gain values . . . . . | 2471 |
| Table 419. | Recommended maximum gain values versus CIC decimation ratios . . . . . | 2473 |
| Table 420. | Most common microphone settings . . . . . | 2474 |
| Table 421. | HPF 3 dB cut-off frequency examples . . . . . | 2476 |
| Table 422. | ANSLP values versus FRSIZE and sampling rates . . . . . | 2489 |
| Table 423. | Threshold values according SNTHR . . . . . | 2490 |
| Table 424. | Register protection summary . . . . . | 2496 |
| Table 425. | Effect of low-power modes on ADF . . . . . | 2497 |
| Table 426. | ADF interrupt requests . . . . . | 2498 |
| Table 427. | Examples of ADF settings for microphone capture . . . . . | 2499 |
| Table 428. | Programming sequence (CIC4) . . . . . | 2500 |
| Table 429. | Programming sequence (CIC5) . . . . . | 2501 |
| Table 430. | Output signal levels . . . . . | 2506 |
| Table 431. | ADF register map and reset values . . . . . | 2529 |
| Table 432. | Camera subsystem RIF peripheral ID . . . . . | 2537 |
| Table 433. | DCMI input/output pins . . . . . | 2543 |
| Table 434. | DCMI internal input/output signals . . . . . | 2543 |
| Table 435. | Positioning of captured data bytes in 32-bit words (8-bit width) . . . . . | 2545 |
| Table 436. | Positioning of captured data bytes in 32-bit words (10-bit width) . . . . . | 2545 |
| Table 437. | Positioning of captured data bytes in 32-bit words (12-bit width) . . . . . | 2545 |
| Table 438. | Positioning of captured data bytes in 32-bit words (14-bit width) . . . . . | 2546 |
| Table 439. | Data storage in monochrome progressive video format . . . . . | 2551 |
| Table 440. | Data storage in RGB progressive video format . . . . . | 2552 |
| Table 441. | Data storage in YCbCr progressive video format . . . . . | 2552 |
| Table 442. | Data storage in YCbCr progressive video format - Y extraction mode . . . . . | 2552 |
| Table 443. | DCMI interrupts . . . . . | 2553 |
| Table 444. | DCMI register map and reset values . . . . . | 2564 |
| Table 445. | Available pipelines . . . . . | 2566 |
| Table 446. | Glossary . . . . . | 2567 |
| Table 447. | DCMIPP input/output pads . . . . . | 2572 |
| Table 448. | DCMIPP input/output pins . . . . . | 2572 |
| Table 449. | DCMIPP clocks . . . . . | 2572 |
| Table 450. | DCMIPP resets . . . . . | 2573 |
| Table 451. | Parallel interface maximum resolution (80 MHz) . . . . . | 2574 |
| Table 452. | Supported pixel formats . . . . . | 2576 |
| Table 453. | DCMIPP_PRCR bit function . . . . . | 2580 |
| Table 454. | DCMIPP_PRESCR and DCMIPP PRESUR bit function . . . . . | 2581 |
| Table 455. | DCMIPP_CMTPGCR1 and DCMIPP_CMTPGCR2 bit function . . . . . | 2582 |
| Table 456. | DCMIPP_PxFCTCR bit function . . . . . | 2590 |
| Table 457. | DCMIPP_P0PPCR bit function . . . . . | 2593 |
| Table 458. | DCMIPP_P0DCCNTR and DCMIPP_P0DCLMTR bit function. . . . . | 2596 |
| Table 459. | DCMIPP_P1SRCR bit function . . . . . | 2598 |
| Table 460. | DCMIPP_P1BPRCR and DCMIPP_P1BPRSR bit function . . . . . | 2599 |
| Table 461. | DCMIPP_P1DECR bit function . . . . . | 2600 |
| Table 462. | DCMIPP_P1STyCR (y = 1, 2, 3), DCMIPP_P1STySR (y = 1, 2, 3), DCMIPP_P1STSTR and DCMIPP_P1STSZR bit function . . . . . | 2601 |
| Table 463. | Statistics extraction: collected data vs. modes . . . . . | 2603 |
| Table 464. | DCMIPP_P1BLCCR bit function . . . . . | 2605 |
| Table 465. | DCMIPP_P1EXCR1 and DCMIPP_P1EXCR2 bit function. . . . . | 2605 |
| Table 466. | DCMIPP_P1DMCR bit function . . . . . | 2607 |
| Table 467. | DCMIPP_P1CTCR1,2,3 bit function . . . . . | 2609 |
| Table 468. | DCMIPP_PxCCyy (yy = R0, R1, G0, G1, B0, B1) bit function . . . . . | 2610 |
| Table 469. | Color conversion: examples of coefficients . . . . . | 2611 |
| Table 470. | DCMIPP_PxCRSTR and DCMIPP_PxCRSZR bit function . . . . . | 2614 |
| Table 471. | DCMIPP_PxDCCR bit function . . . . . | 2615 |
| Table 472. | DCMIPP_PxDSCR, DCMIPP_PxDSTRIOR, DCMIPP_PxDSSZR. . . . . | 2616 |
| Table 473. | DCMIPP_PxPPCR bit function . . . . . | 2618 |
| Table 474. | Parallel interface input pixel formats. . . . . | 2631 |
| Table 475. | Correspondence between index and DCMIPP_PRCR register values. . . . . | 2632 |
| Table 476. | Parallel interface input pixel formats. . . . . | 2633 |
| Table 477. | Pixel pipe output pixel format . . . . . | 2633 |
| Table 478. | Dump pipe OUTPUT pixel formats . . . . . | 2635 |
| Table 479. | Shadow and physical registers . . . . . | 2642 |
| Table 480. | DCMIPP low power modes. . . . . | 2644 |
| Table 481. | DCMIPP interrupts . . . . . | 2647 |
| Table 482. | Event connection . . . . . | 2648 |
| Table 483. | DCMIPP registers organization . . . . . | 2649 |
| Table 484. | DCMIPP register map and reset values . . . . . | 2743 |
| Table 485. | Glossary of terms . . . . . | 2757 |
| Table 486. | Effect of low-power modes on CSI-2 Host controller . . . . . | 2776 |
| Table 487. | List of errors detected by the CSI-2 Host controller . . . . . | 2776 |
| Table 488. | List of events that trigger an interrupt . . . . . | 2777 |
| Table 489. | CSI-2 Host and PHY register map and reset values . . . . . | 2815 |
| Table 490. | PSSI input/output pins . . . . . | 2821 |
| Table 491. | PSSI internal input/output signals. . . . . | 2821 |
| Table 492. | Positioning of captured data bytes in 32-bit words (8-bit width) . . . . . | 2822 |
| Table 493. | Positioning of captured data bytes in 32-bit words (16-bit width) . . . . . | 2823 |
| Table 494. | PSSI interrupt requests. . . . . | 2826 |
| Table 495. | PSSI register map and reset values . . . . . | 2833 |
| Table 496. | Display subsystem RIF peripheral ID . . . . . | 2843 |
| Table 497. | LTDC pins. . . . . | 2853 |
| Table 498. | Clock domain for each register . . . . . | 2854 |
| Table 499. | LTDC register access and updated durations . . . . . | 2856 |
| Table 500. | Pixel data mapping versus color format . . . . . | 2859 |
| Table 501. | LTDC interrupt requests . . . . . | 2878 |
| Table 502. | LTDC register map and reset values . . . . . | 2916 |
| Table 503. | LVDS Data mapping for VESA and JEIDA. . . . . | 2929 |
| Table 504. | LVDS register map and reset values . . . . . | 3013 |
| Table 505. | DSI pins . . . . . | 3034 |
| Table 506. | DSI internal input/output signals . . . . . | 3034 |
| Table 507. | Location of color components in the LTDC interface . . . . . | 3037 |
| Table 508. | Multiplicity of the payload size in pixels, for each data type . . . . . | 3038 |
| Table 509. | Contention detection timeout counters configuration . . . . . | 3050 |
| Table 510. | List of events of different categories of the PRESP_TO counter . . . . . | 3051 |
| Table 511. | PRESP_TO counter configuration . . . . . | 3054 |
| Table 512. | Frame requirement configuration registers . . . . . | 3065 |
| Table 513. | RGB components . . . . . | 3067 |
| Table 514. | PLL regulation settings in function of the target frequency . . . . . | 3071 |
| Table 515. | PLL frequency range and timings vs. target frequency . . . . . | 3071 |
| Table 516. | DSI Wrapper interrupt requests . . . . . | 3074 |
| Table 517. | Error causes and recovery . . . . . | 3075 |
| Table 518. | DSI register map and reset values . . . . . | 3146 |
| Table 519. | VENC register map and reset values . . . . . | 3250 |
| Table 520. | VDEC register map and reset values . . . . . | 3297 |
| Table 521. | RNG internal input/output signals . . . . . | 3302 |
| Table 522. | RNG interrupt requests . . . . . | 3310 |
| Table 523. | RNG initialization times . . . . . | 3311 |
| Table 524. | RNG configurations . . . . . | 3311 |
| Table 525. | Configuration selection . . . . . | 3312 |
| Table 526. | RNG register map and reset map . . . . . | 3319 |
| Table 527. | CRYP1/CRYP2 versus SAES features . . . . . | 3321 |
| Table 528. | SAES internal input/output signals . . . . . | 3322 |
| Table 529. | SAES approved symmetric key functions . . . . . | 3323 |
| Table 530. | Counter mode initialization vector definition . . . . . | 3333 |
| Table 531. | Initialization of IV registers in GCM mode . . . . . | 3336 |
| Table 532. | GCM last block definition . . . . . | 3336 |
| Table 533. | Initialization of IV registers in CCM mode . . . . . | 3342 |
| Table 534. | AES data swapping example . . . . . | 3351 |
| Table 535. | Key endianness in SAES_KEYRx registers (128/256-bit keys) . . . . . | 3353 |
| Table 536. | IVI bitfield spread over SAES_IVRx registers . . . . . | 3355 |
| Table 537. | SAES interrupt requests . . . . . | 3357 |
| Table 538. | Processing latency for ECB, CBC and CTR . . . . . | 3358 |
| Table 539. | Processing latency for GCM and CCM (in SAES kernel clock cycles) . . . . . | 3358 |
| Table 540. | SAES register map and reset values . . . . . | 3374 |
| Table 541. | CRYP versus SAES features . . . . . | 3378 |
| Table 542. | CRYP internal input/output signals . . . . . | 3380 |
| Table 543. | CRYP approved AES symmetric key functions . . . . . | 3380 |
| Table 544. | CRYP approved DES/TDES symmetric key functions . . . . . | 3380 |
| Table 545. | Counter mode initialization vector definition . . . . . | 3394 |
| Table 546. | GCM mode IVI registers initialization . . . . . | 3397 |
| Table 547. | GCM last block definition . . . . . | 3397 |
| Table 548. | CCM mode IVI registers initialization . . . . . | 3404 |
| Table 549. | DES/TDES data swapping example . . . . . | 3409 |
| Table 550. | AES data swapping example . . . . . | 3410 |
| Table 551. | Key endianness in CRYP_KxR/LR registers (AES 128/192/256-bit keys) . . . . . | 3412 |
| Table 552. | Key endianness in CRYP_KxR/LR registers (DES K1 and TDES K1/2/3) . . . . . | 3412 |
| Table 553. | Initialization vector endianness in CRYP_IVxR registers (AES) . . . . . | 3413 |
| Table 554. | Initialization vector endianness in CRYP_IVxR registers (DES/TDES) . . . . . | 3413 |
| Table 555. | CRYP interrupt requests . . . . . | 3415 |
| Table 556. | Processing latency for ECB, CBC and CTR . . . . . | 3416 |
| Table 557. | Processing latency for GCM and CCM (in clock cycles) . . . . . | 3417 |
| Table 558. | CRYP register map and reset values | 3432 |
| Table 559. | HASH internal input/output signals | 3437 |
| Table 560. | Information on supported hash algorithms | 3437 |
| Table 561. | Hash processor outputs | 3441 |
| Table 562. | Processing time (in clock cycle) | 3448 |
| Table 563. | HASH interrupt requests | 3449 |
| Table 564. | HASH1 register map and reset values | 3460 |
| Table 565. | OTFDEC internal input/output signals | 3464 |
| Table 566. | OTFDEC interrupt requests | 3468 |
| Table 567. | OTFDEC register map and reset values | 3481 |
| Table 568. | Internal input/output signals | 3486 |
| Table 569. | PKA integer arithmetic functions list | 3487 |
| Table 570. | PKA prime field (\(F_p\)) elliptic curve functions list | 3488 |
| Table 571. | Montgomery parameter computation | 3494 |
| Table 572. | Modular addition | 3495 |
| Table 573. | Modular subtraction | 3495 |
| Table 574. | Montgomery multiplication | 3496 |
| Table 575. | Modular exponentiation (normal mode) | 3497 |
| Table 576. | Modular exponentiation (fast mode) | 3497 |
| Table 577. | Modular exponentiation (protected mode) | 3498 |
| Table 578. | Modular inversion | 3498 |
| Table 579. | Modular reduction | 3499 |
| Table 580. | Arithmetic addition | 3499 |
| Table 581. | Arithmetic subtraction | 3499 |
| Table 582. | Arithmetic multiplication | 3500 |
| Table 583. | Arithmetic comparison | 3500 |
| Table 584. | CRT exponentiation | 3501 |
| Table 585. | Point on elliptic curve \(F_p\) check | 3502 |
| Table 586. | ECC \(F_p\) scalar multiplication | 3502 |
| Table 587. | ECDSA sign - Inputs | 3504 |
| Table 588. | ECDSA sign - Outputs | 3504 |
| Table 589. | Extended ECDSA sign - Extra outputs | 3505 |
| Table 590. | ECDSA verification - Inputs | 3505 |
| Table 591. | ECDSA verification - Outputs | 3506 |
| Table 592. | ECC complete addition | 3506 |
| Table 593. | ECC double base ladder | 3507 |
| Table 594. | ECC projective to affine | 3508 |
| Table 595. | Family of supported curves for ECC operations | 3509 |
| Table 596. | Modular exponentiation | 3510 |
| Table 597. | ECC scalar multiplication | 3510 |
| Table 598. | ECDSA signature average computation time | 3511 |
| Table 599. | ECDSA verification average computation times | 3511 |
| Table 600. | ECC double base ladder average computation times | 3511 |
| Table 601. | ECC projective to affine average computation times | 3511 |
| Table 602. | ECC complete addition average computation times | 3511 |
| Table 603. | Point on elliptic curve \(F_p\) check average computation times | 3511 |
| Table 604. | Montgomery parameters average computation times | 3512 |
| Table 605. | PKA interrupt requests | 3512 |
| Table 606. | PKA register map and reset values | 3519 |
| Table 607. | TIM input/output pins | 3522 |
| Table 608. | TIM internal input/output signals | 3522 |
| Table 609. | Interconnect to the tim_ti1 input multiplexer | 3523 |
| Table 610. | Interconnect to the tim_ti2 input multiplexer . . . . . | 3523 |
| Table 611. | Interconnect to the tim_ti3 input multiplexer . . . . . | 3524 |
| Table 612. | Interconnect to the tim_ti4 input multiplexer . . . . . | 3524 |
| Table 613. | Internal trigger connection . . . . . | 3524 |
| Table 614. | Interconnect to the tim_etr input multiplexer . . . . . | 3525 |
| Table 615. | Timer break interconnect . . . . . | 3525 |
| Table 616. | Timer break2 interconnect . . . . . | 3526 |
| Table 617. | System break interconnect . . . . . | 3526 |
| Table 618. | CCR and ARR register change dithering pattern . . . . . | 3558 |
| Table 619. | CCR register change dithering pattern in center-aligned PWM mode . . . . . | 3559 |
| Table 620. | Behavior of timer outputs versus tim_brk/tim_brk2 inputs . . . . . | 3571 |
| Table 621. | Break protection disarming conditions . . . . . | 3573 |
| Table 622. | Counting direction versus encoder signals (CC1P = CC2P = 0) . . . . . | 3581 |
| Table 623. | Counting direction versus encoder signals and polarity settings . . . . . | 3585 |
| Table 624. | DMA request . . . . . | 3606 |
| Table 625. | Effect of low-power modes on TIM1/TIM8/TIM20 . . . . . | 3607 |
| Table 626. | Interrupt requests . . . . . | 3607 |
| Table 627. | Output control bits for complementary tim_ocx and tim_ocxn channels with break feature . . . . . | 3634 |
| Table 628. | TIMx register map and reset values . . . . . | 3661 |
| Table 629. | STM32MP23/25xx general purpose timers . . . . . | 3665 |
| Table 630. | TIM input/output pins . . . . . | 3667 |
| Table 631. | TIM internal input/output signals . . . . . | 3667 |
| Table 632. | Interconnect to the tim_ti1 input multiplexer . . . . . | 3668 |
| Table 633. | Interconnect to the tim_ti2 input multiplexer . . . . . | 3668 |
| Table 634. | Interconnect to the tim_ti3 input multiplexer . . . . . | 3668 |
| Table 635. | Interconnect to the tim_ti4 input multiplexer . . . . . | 3669 |
| Table 636. | TIMx internal trigger connection . . . . . | 3669 |
| Table 637. | Interconnect to the tim_etr input multiplexer . . . . . | 3669 |
| Table 638. | CCR and ARR register change dithering pattern . . . . . | 3701 |
| Table 639. | CCR register change dithering pattern in center-aligned PWM mode . . . . . | 3702 |
| Table 640. | Counting direction versus encoder signals(CC1P = CC2P = 0) . . . . . | 3711 |
| Table 641. | Counting direction versus encoder signals and polarity settings . . . . . | 3716 |
| Table 642. | DMA request . . . . . | 3740 |
| Table 643. | Effect of low-power modes on TIM2/TIM3/TIM4/TIM5 . . . . . | 3740 |
| Table 644. | Interrupt requests . . . . . | 3741 |
| Table 645. | Output control bit for standard tim_ocx channels . . . . . | 3762 |
| Table 646. | TIM2/TIM3/TIM4/TIM5 register map and reset values . . . . . | 3777 |
| Table 647. | TIM internal input/output signals . . . . . | 3781 |
| Table 648. | TIMx_ARR register change dithering pattern . . . . . | 3791 |
| Table 649. | DMA request . . . . . | 3792 |
| Table 650. | Effect of low-power modes on TIM6/TIM7 . . . . . | 3792 |
| Table 651. | Interrupt request . . . . . | 3792 |
| Table 652. | TIMx register map and reset values . . . . . | 3802 |
| Table 653. | TIM input/output pins . . . . . | 3807 |
| Table 654. | TIM internal input/output signals . . . . . | 3807 |
| Table 655. | Interconnect to the tim_ti1 input multiplexer . . . . . | 3808 |
| Table 656. | Interconnect to the tim_ti2 input multiplexer . . . . . | 3808 |
| Table 657. | TIMx internal trigger connection . . . . . | 3808 |
| Table 658. | CCR and ARR register change dithering pattern . . . . . | 3826 |
| Table 659. | Effect of low-power modes on TIM10/TIM11/TIM12/TIM13/TIM14 . . . . . | 3835 |
| Table 660. | Interrupt requests . . . . . | 3835 |
| Table 661. | Output control bit for standard tim_ocx channels . . . . . | 3848 |
| Table 662. | TIM12 register map and reset values . . . . . | 3856 |
| Table 663. | Output control bit for standard tim_ocx channels . . . . . | 3865 |
| Table 664. | TIM10/TIM11/TIM13/TIM14 register map and reset values . . . . . | 3872 |
| Table 665. | TIM input/output pins . . . . . | 3877 |
| Table 666. | TIM internal input/output signals . . . . . | 3878 |
| Table 667. | Interconnect to the tim_ti1 input multiplexer . . . . . | 3878 |
| Table 668. | Interconnect to the tim_ti2 input multiplexer . . . . . | 3879 |
| Table 669. | TIMx internal trigger connection . . . . . | 3879 |
| Table 670. | Timer break interconnect . . . . . | 3880 |
| Table 671. | System break interconnect . . . . . | 3880 |
| Table 672. | CCR and ARR register change dithering pattern . . . . . | 3900 |
| Table 673. | Break protection disarming conditions . . . . . | 3909 |
| Table 674. | DMA request . . . . . | 3920 |
| Table 675. | Effect of low-power modes on TIM15/TIM16/TIM17 . . . . . | 3921 |
| Table 676. | Interrupt requests . . . . . | 3921 |
| Table 677. | Output control bits for complementary tim_ocx and tim_ocxn channels with break feature (TIM15) . . . . . | 3937 |
| Table 678. | TIM15 register map and reset values . . . . . | 3953 |
| Table 679. | Output control bits for complementary tim_oc1 and tim_oc1n channels with break feature (TIM16/TIM17) . . . . . | 3967 |
| Table 680. | TIM16/TIM17 register map and reset values . . . . . | 3984 |
| Table 681. | STM32MP23/25xx LPTIM features . . . . . | 3988 |
| Table 682. | LPTIM1/2/3/4 input/output pins . . . . . | 3990 |
| Table 683. | LPTIM5 input/output pins . . . . . | 3990 |
| Table 684. | LPTIM1/2/3/4 internal signals . . . . . | 3991 |
| Table 685. | LPTIM5 internal signals . . . . . | 3991 |
| Table 686. | LPTIM1/2/3/4/5 external trigger connections . . . . . | 3992 |
| Table 687. | LPTIM1/2/3/4/5 input 1 connections . . . . . | 3992 |
| Table 688. | LPTIM1/2 input 2 connections . . . . . | 3992 |
| Table 689. | LPTIM1/2/3/4 input capture 1 connections . . . . . | 3992 |
| Table 690. | LPTIM1/2/3 input capture 2 connections . . . . . | 3993 |
| Table 691. | Prescaler division ratios . . . . . | 3994 |
| Table 692. | Encoder counting scenarios . . . . . | 4001 |
| Table 693. | Input capture Glitch filter latency (in counter step unit) . . . . . | 4005 |
| Table 694. | Effect of low-power modes on the LPTIM . . . . . | 4010 |
| Table 695. | Interrupt events . . . . . | 4011 |
| Table 696. | LPTIM register map and reset values . . . . . | 4038 |
| Table 697. | STGENC register map and reset values . . . . . | 4056 |
| Table 698. | STGENR register map and reset values . . . . . | 4057 |
| Table 699. | STM32MP23/25xx IWDG features . . . . . | 4062 |
| Table 700. | IWDG delays versus actions . . . . . | 4063 |
| Table 701. | IWDG internal input/output signals . . . . . | 4064 |
| Table 702. | Effect of low power modes on IWDG . . . . . | 4069 |
| Table 703. | IWDG interrupt request . . . . . | 4071 |
| Table 704. | IWDG register map and reset values . . . . . | 4079 |
| Table 705. | STM32MP23/25xx WWDG features . . . . . | 4080 |
| Table 706. | WWDG internal input/output signals . . . . . | 4081 |
| Table 707. | WWDG register map and reset values . . . . . | 4087 |
| Table 708. | RTC input/output pins . . . . . | 4092 |
| Table 709. | RTC internal input/output signals . . . . . | 4092 |
| Table 710. | RTC interconnection . . . . . | 4093 |
| Table 711. | RTC pin PC13 configuration . . . . . | 4093 |
| Table 712. | PI8 configuration . . . . . | 4096 |
| Table 713. | RTC_OUT mapping . . . . . | 4097 |
| Table 714. | RTC resource number allocation . . . . . | 4100 |
| Table 715. | Effect of low-power modes on RTC . . . . . | 4114 |
| Table 716. | RTC pins functionality over modes . . . . . | 4114 |
| Table 717. | Nonsecure interrupt requests . . . . . | 4115 |
| Table 718. | Secure interrupt requests . . . . . | 4116 |
| Table 719. | RTC register map and reset values . . . . . | 4152 |
| Table 720. | TAMP input/output pins . . . . . | 4158 |
| Table 721. | TAMP internal input/output signals . . . . . | 4158 |
| Table 722. | TAMP interconnection . . . . . | 4159 |
| Table 723. | CID regions . . . . . | 4163 |
| Table 724. | RIF TAMP resource number allocation . . . . . | 4164 |
| Table 725. | Device resource x tamper protection . . . . . | 4168 |
| Table 726. | Active tamper output change period . . . . . | 4171 |
| Table 727. | Minimum ATPER value . . . . . | 4172 |
| Table 728. | Active tamper filtered pulse duration . . . . . | 4173 |
| Table 729. | Effect of low-power modes on TAMP . . . . . | 4174 |
| Table 730. | TAMP pins functionality over modes . . . . . | 4175 |
| Table 731. | Nonsecure interrupt requests . . . . . | 4175 |
| Table 732. | Secure interrupt requests . . . . . | 4176 |
| Table 733. | TAMP register map and reset values . . . . . | 4213 |
| Table 734. | I2C implementation . . . . . | 4217 |
| Table 735. | I2C input/output pins . . . . . | 4218 |
| Table 736. | I2C internal input/output signals . . . . . | 4219 |
| Table 737. | I2C8 interconnection . . . . . | 4219 |
| Table 738. | Comparison of analog and digital filters . . . . . | 4221 |
| Table 739. | I2C-bus and SMBus specification data setup and hold times . . . . . | 4223 |
| Table 740. | I2C configuration . . . . . | 4227 |
| Table 741. | I2C-bus and SMBus specification clock timings . . . . . | 4238 |
| Table 742. | Timing settings for fI2CCLK of 8 MHz . . . . . | 4248 |
| Table 743. | Timing settings for fI2CCLK of 16 MHz . . . . . | 4248 |
| Table 744. | SMBus timeout specifications . . . . . | 4250 |
| Table 745. | SMBus with PEC configuration . . . . . | 4252 |
| Table 746. | TIMEOUTA[11:0] for maximum tTIMEOUT of 25 ms . . . . . | 4253 |
| Table 747. | TIMEOUTB[11:0] for maximum tLOW:SEXT and tLOW:MEXT of 8 ms . . . . . | 4253 |
| Table 748. | TIMEOUTA[11:0] for maximum tIDLE of 50 µs . . . . . | 4253 |
| Table 749. | Effect of low-power modes to I2C . . . . . | 4263 |
| Table 750. | I2C interrupt requests . . . . . | 4264 |
| Table 751. | I2C register map and reset values . . . . . | 4282 |
| Table 752. | I3C instantiation . . . . . | 4286 |
| Table 753. | I3C wake-up . . . . . | 4286 |
| Table 754. | I3C autonomous mode with DMA in Stop mode(s) . . . . . | 4286 |
| Table 755. | I3C FIFOs implementation . . . . . | 4286 |
| Table 756. | I3C interrupt(s) . . . . . | 4287 |
| Table 757. | I3C peripheral controller/target features versus MIPI v1.1 . . . . . | 4288 |
| Table 758. | I3C input/output pins . . . . . | 4289 |
| Table 759. | I3C internal input/output signals . . . . . | 4289 |
| Table 760. | I3C register usage . . . . . | 4301 |
| Table 761. | I3C registers/fields usage versus controller state . . . . . | 4302 |
| Table 762. | I3C registers/fields usage versus target state . . . . . | 4305 |
| Table 763. | List of supported I3C CCCs, as controller/target | 4308 |
| Table 764. | I3C controller error management | 4339 |
| Table 765. | I3C target error management | 4341 |
| Table 766. | Effect of low-power modes | 4345 |
| Table 767. | I3C interrupt requests | 4346 |
| Table 768. | I3C register map and reset values | 4392 |
| Table 769. | Instance implementation on STM32MP23/25xx | 4397 |
| Table 770. | USART/LPUART features | 4398 |
| Table 771. | USART/UART input/output pins | 4400 |
| Table 772. | USART internal input/output signals | 4401 |
| Table 773. | USART interconnection (USART1/2/3/6 and UART4/5/7/8/9) | 4401 |
| Table 774. | Noise detection from sampled data | 4413 |
| Table 775. | Tolerance of the USART receiver when BRR [3:0] = 0000 | 4417 |
| Table 776. | Tolerance of the USART receiver when BRR[3:0] is different from 0000 | 4417 |
| Table 777. | USART frame formats | 4422 |
| Table 778. | Effect of low-power modes on the USART | 4443 |
| Table 779. | USART interrupt requests | 4444 |
| Table 780. | USART register map and reset values | 4486 |
| Table 781. | Instance implementation on STM32MP23/25xx | 4489 |
| Table 782. | USART/LPUART features | 4489 |
| Table 783. | LPUART input/output pins | 4492 |
| Table 784. | LPUART internal input/output signals | 4492 |
| Table 785. | LPUART interconnections (LPUART1) | 4493 |
| Table 786. | Error calculation for programmed baud rates at lpuart_ker_ck_pres= 32.768 kHz | 4504 |
| Table 787. | Tolerance of the LPUART receiver | 4505 |
| Table 789. | Effect of low-power modes on the LPUART | 4516 |
| Table 790. | LPUART interrupt requests | 4517 |
| Table 791. | LPUART register map and reset values | 4546 |
| Table 792. | SPI features | 4549 |
| Table 793. | SPI/I2S input/output pins | 4551 |
| Table 794. | SPI internal input/output signals | 4552 |
| Table 795. | SPI interconnection (SPI8) | 4552 |
| Table 796. | Effect of low-power modes on the SPI | 4582 |
| Table 797. | SPI wake-up and interrupt requests | 4583 |
| Table 798. | Bitfields usable in PCM/I2S mode | 4585 |
| Table 799. | WS and CK level before SPI/I2S is enabled when AFCNTR = 1 | 4594 |
| Table 800. | Serial data line swapping | 4594 |
| Table 801. | CLKGEN programming examples for usual I2S frequencies | 4598 |
| Table 802. | I2S interrupt requests | 4607 |
| Table 803. | SPI register map and reset values | 4629 |
| Table 804. | SAI features | 4632 |
| Table 805. | SAI internal input/output signals | 4634 |
| Table 806. | SAI input/output pins | 4634 |
| Table 807. | External synchronization selection | 4637 |
| Table 808. | MCLK_x activation conditions | 4642 |
| Table 809. | Clock generator programming examples | 4645 |
| Table 810. | TDM settings | 4652 |
| Table 811. | TDM frame configuration examples | 4654 |
| Table 812. | SOPD pattern | 4658 |
| Table 813. | Parity bit calculation | 4658 |
| Table 814. | Audio sampling frequency versus symbol rates | 4659 |
| Table 815. | SAI interrupt sources | 4668 |
| Table 816. | SAI register map and reset values | 4698 |
| Table 817. | SPDIFRX internal input/output signals | 4702 |
| Table 818. | SPDIFRX pins | 4702 |
| Table 819. | Transition sequence for preamble | 4708 |
| Table 820. | Minimum spdifrx_ker_ck frequency versus audio sampling rate | 4718 |
| Table 821. | Conditions of spdifrx_symb_ck generation | 4719 |
| Table 822. | Bit field property versus SPDIFRX state | 4722 |
| Table 823. | SPDIFRX interface register map and reset values | 4735 |
| Table 824. | CAN subsystem I/O signals | 4737 |
| Table 825. | CAN subsystem I/O pins | 4738 |
| Table 826. | CAN triggers | 4738 |
| Table 827. | Main features | 4740 |
| Table 828. | DLC coding in FDCAN | 4745 |
| Table 829. | Example of filter configuration for Rx buffers | 4758 |
| Table 830. | Example of filter configuration for Debug messages | 4759 |
| Table 831. | Possible configurations for frame transmission | 4759 |
| Table 832. | Tx buffer/FIFO - Queue element size | 4760 |
| Table 833. | First byte of level 1 reference message | 4770 |
| Table 834. | First four bytes of level 2 reference message | 4771 |
| Table 835. | First four bytes of level 0 reference message | 4771 |
| Table 836. | TUR configuration example | 4772 |
| Table 837. | System matrix, Node A | 4777 |
| Table 838. | Trigger list, Node A | 4778 |
| Table 839. | Number of data bytes transmitted with a reference message | 4785 |
| Table 840. | Rx buffer and FIFO element | 4792 |
| Table 841. | Rx buffer and FIFO element description | 4792 |
| Table 842. | Tx buffer and FIFO element | 4794 |
| Table 843. | Tx buffer element description | 4794 |
| Table 844. | Tx Event FIFO element | 4796 |
| Table 845. | Tx Event FIFO element description | 4796 |
| Table 846. | Standard message ID filter element | 4797 |
| Table 847. | Standard message ID filter element field description | 4798 |
| Table 848. | Extended message ID filter element | 4799 |
| Table 849. | Extended message ID filter element field description | 4799 |
| Table 850. | Trigger memory element | 4800 |
| Table 851. | Trigger memory element description | 4800 |
| Table 852. | FDCAN register map and reset values | 4838 |
| Table 853. | FDCAN TT register map and reset values | 4860 |
| Table 854. | CCU register map and reset values | 4866 |
| Table 855. | Implementation parameters | 4869 |
| Table 856. | USB2 host high-speed port pins | 4871 |
| Table 857. | USB2 host high-speed port internal signals | 4871 |
| Table 858. | USB2 host high-speed port interrupts | 4873 |
| Table 859. | USB2 host high-speed port wake-up event | 4873 |
| Table 860. | Connections to SYSCFG | 4874 |
| Table 861. | USB3 DRD implementation parameters | 4877 |
| Table 862. | USB3 DRD port pins | 4878 |
| Table 863. | USB3 DRD port internal signals | 4879 |
| Table 864. | USB3 DRD port interrupts | 4881 |
| Table 865. | USB3 DRD port wake-up events | 4881 |
| Table 866. | USB3DR_GBL_GGPIO bit description | 4882 |
| Table 867. | Connections to SYSCFG | 4886 |
| Table 868. | USB Type-C and power delivery pins . . . . . | 4892 |
| Table 869. | USB Type-C and power delivery internal signals . . . . . | 4892 |
| Table 870. | USB Type-C controller interrupt . . . . . | 4893 |
| Table 871. | USB Type-C and power delivery events . . . . . | 4893 |
| Table 872. | USB3DR register map . . . . . | 4896 |
| Table 873. | USB3DR register map and reset values . . . . . | 4987 |
| Table 874. | USBH register map and reset values . . . . . | 5008 |
| Table 875. | UCPD implementation . . . . . | 5013 |
| Table 876. | UCPD software trim data . . . . . | 5013 |
| Table 877. | UCPD signals on pins . . . . . | 5014 |
| Table 878. | UCPD internal signals . . . . . | 5014 |
| Table 879. | 4b5b symbol encoding table . . . . . | 5016 |
| Table 880. | Ordered sets . . . . . | 5017 |
| Table 881. | Validation of ordered sets . . . . . | 5018 |
| Table 882. | Data size . . . . . | 5018 |
| Table 883. | Coding for ANAMODE, ANASUBMODE and link with TYPEC_VSTATE_CCx . . . . . | 5027 |
| Table 884. | Type-C sequence (source: 3A); cable/sink connected (Rd on CC1; Ra on CC2) . . . . . | 5028 |
| Table 885. | Effect of low power modes on the UCPD . . . . . | 5030 |
| Table 886. | UCPD interrupt requests . . . . . | 5031 |
| Table 887. | UCPD register map and reset values . . . . . | 5048 |
| Table 888. | PCIESS register list . . . . . | 5054 |
| Table 889. | COMBOPHY register programming: reference clock . . . . . | 5059 |
| Table 890. | COMBOPHY register map and reset values . . . . . | 5060 |
| Table 891. | PHY interface selection . . . . . | 5064 |
| Table 892. | Ethernet peripheral pins . . . . . | 5072 |
| Table 893. | Ethernet internal input/output signals . . . . . | 5073 |
| Table 894. | Fixed priority scheme for DMA channels . . . . . | 5088 |
| Table 895. | Routing DA/SA failed packets to Rx queue . . . . . | 5093 |
| Table 896. | Routing DA/SA pass but VLAN filter fail packets to Rx queue . . . . . | 5093 |
| Table 897. | Priority routing of filter pass packets when OMCBCQ = 0 . . . . . | 5093 |
| Table 898. | Priority routing of filter pass packets when OMCBCQ = 1 . . . . . | 5094 |
| Table 899. | Weight for DMA channels . . . . . | 5096 |
| Table 900. | Example of credit value per transmit cycle . . . . . | 5097 |
| Table 901. | Double VLAN processing features in Tx path . . . . . | 5100 |
| Table 902. | Double VLAN processing in Rx path . . . . . | 5101 |
| Table 903. | VLAN insertion or replacement based on VLTI bit . . . . . | 5102 |
| Table 904. | Destination address filtering . . . . . | 5106 |
| Table 905. | Source address filtering . . . . . | 5107 |
| Table 906. | VLAN match status . . . . . | 5108 |
| Table 907. | OTS and ITS bit values with at least one perfect filter enabled . . . . . | 5111 |
| Table 908. | OTS and ITS bit values with only VLAN Hash filter enabled . . . . . | 5112 |
| Table 909. | Rx Queue routing table for Unicast-tagged packets . . . . . | 5113 |
| Table 910. | Ordinary clock: PTP messages for snapshot . . . . . | 5116 |
| Table 911. | End-to-end transparent clock: PTP messages for snapshot . . . . . | 5117 |
| Table 912. | Peer-to-peer transparent clock: PTP messages for snapshot . . . . . | 5118 |
| Table 913. | Egress and ingress latency for PHY interfaces . . . . . | 5122 |
| Table 914. | Minimum PTP clock frequency example . . . . . | 5122 |
| Table 915. | Message format defined in IEEE 1588-2008 . . . . . | 5123 |
| Table 916. | Message format defined in IEEE 1588-2008 . . . . . | 5124 |
| Table 917. | IPv6-UDP PTP packet fields required for control and status . . . . . | 5125 |
| Table 918. | Ethernet PTP packet fields required for control and status . . . . . | 5126 |
| Table 919. | Timestamp Snapshot Dependency on ETH_MACTSCR bits . . . . . | 5127 |
| Table 920. | PTP message generation criteria . . . . . | 5133 |
| Table 921. | Common PTP message header fields . . . . . | 5135 |
| Table 922. | MAC Transmit PTP mode and one-step timestamping operation. . . . . | 5138 |
| Table 923. | External memory used for holding the two gate-control lists . . . . . | 5143 |
| Table 924. | GCL and associated registers - BTR and CTR. . . . . | 5147 |
| Table 925. | GCL and associated registers - BTR and CTR, execution time > CycleTime . . . . . | 5148 |
| Table 926. | GCL and Associated Registers - BTR and CTR. . . . . | 5150 |
| Table 927. | Extending to New List By Truncating the Current List . . . . . | 5151 |
| Table 928. | Switching to New List By Extending the Current List . . . . . | 5152 |
| Table 929. | Gate Control List When FPE is disabled . . . . . | 5154 |
| Table 930. | Gate Control List When FPE is enabled . . . . . | 5154 |
| Table 931. | Valid SMD Values of mPacket . . . . . | 5157 |
| Table 932. | Valid frag_count values . . . . . | 5157 |
| Table 933. | Current and Previous SMD Values. . . . . | 5158 |
| Table 934. | Current and previous SMD values . . . . . | 5158 |
| Table 935. | Preemption Control Values on MRI Interface for Various Frame Types. . . . . | 5162 |
| Table 936. | MMC Counters and Associated Interrupt Registers . . . . . | 5163 |
| Table 937. | Transmit checksum offload engine functions for different packet types . . . . . | 5172 |
| Table 938. | Receive checksum offload engine functions for different packet types . . . . . | 5175 |
| Table 939. | TSO: TCP and IP header fields . . . . . | 5179 |
| Table 940. | Pause packet fields. . . . . | 5184 |
| Table 941. | Tx MAC flow control . . . . . | 5185 |
| Table 942. | Rx MAC flow control . . . . . | 5186 |
| Table 943. | Size of the maximum receive packet . . . . . | 5190 |
| Table 944. | MCD clock selection . . . . . | 5193 |
| Table 945. | MDIO Clause 45 frame structure . . . . . | 5194 |
| Table 946. | MDIO Clause 22 frame structure . . . . . | 5195 |
| Table 947. | Remote wake-up packet filter register . . . . . | 5208 |
| Table 948. | Description of the remote wake-up filter fields . . . . . | 5209 |
| Table 949. | Remote wake-up packet and PMT interrupt generation . . . . . | 5210 |
| Table 950. | Transfer complete interrupt behavior . . . . . | 5219 |
| Table 951. | TDES0 normal descriptor (read format) . . . . . | 5250 |
| Table 952. | TDES1 normal descriptor (read format) . . . . . | 5251 |
| Table 953. | TDES2 normal descriptor (read format) . . . . . | 5251 |
| Table 954. | TDES3 normal descriptor (read format) . . . . . | 5252 |
| Table 955. | TDES0 normal descriptor (write-back format). . . . . | 5255 |
| Table 956. | TDES1 normal descriptor (write-back format). . . . . | 5255 |
| Table 957. | TDES2 normal descriptor (write-back format). . . . . | 5256 |
| Table 958. | TDES3 normal descriptor (write-back format). . . . . | 5256 |
| Table 959. | TDES0 context descriptor. . . . . | 5260 |
| Table 960. | TDES1 context descriptor. . . . . | 5260 |
| Table 961. | TDES2 context descriptor. . . . . | 5261 |
| Table 962. | TDES3 context descriptor. . . . . | 5261 |
| Table 963. | RDES0 normal descriptor (read format) . . . . . | 5264 |
| Table 964. | RDES1 normal descriptor (read format) . . . . . | 5264 |
| Table 965. | RDES2 normal descriptor (read format) . . . . . | 5264 |
| Table 966. | RDES3 normal descriptor (read format) . . . . . | 5265 |
| Table 967. | RDES0 normal descriptor (write-back format) . . . . . | 5266 |
| Table 968. | RDES1 normal descriptor (write-back format) . . . . . | 5267 |
| Table 969. | RDES2 normal descriptor (write-back format) . . . . . | 5269 |
| Table 970. | RDES3 normal descriptor (write-back format) . . . . . | 5271 |
| Table 971. | RDES0 context descriptor . . . . . | 5274 |
| Table 972. | RDES1 context descriptor | 5275 |
| Table 973. | RDES2 context descriptor | 5275 |
| Table 974. | RDES3 context descriptor | 5275 |
| Table 975. | Enhanced normal descriptor (read format) | 5276 |
| Table 976. | ETH_DMA common register map and reset values | 5309 |
| Table 977. | ETH_DMA_CH register map and reset values | 5310 |
| Table 978. | ETH_DMA_CH1 register map and reset values | 5312 |
| Table 979. | ETH_DMA_CH2 register map and reset values | 5314 |
| Table 980. | ETH_DMA_CH3 register map and reset values | 5315 |
| Table 981. | ETH_MTL register map and reset values | 5345 |
| Table 982. | Giant Packet Status based on S2KP and JE Bits | 5356 |
| Table 983. | Packet Length based on the CST and ACS bits | 5356 |
| Table 984. | Ethernet MAC register map and reset values | 5499 |
| Table 985. | Ethernet peripheral pins | 5519 |
| Table 986. | ETHSW internal input/output signals | 5520 |
| Table 987. | SMD values | 5530 |
| Table 988. | Encoding of frame count in SMD-S | 5534 |
| Table 989. | Encoding of frame count in SMD-C | 5534 |
| Table 990. | Encoding of fragment count | 5534 |
| Table 991. | Management Trailer SMD bit usage, frames from CPU to FES | 5549 |
| Table 992. | Management Trailer SMD bit usage, frames from FES to CPU | 5550 |
| Table 993. | Keeping, adding or removing R-TAG | 5565 |
| Table 994. | Interrupt requests | 5580 |
| Table 995. | Register maps summary | 5581 |
| Table 996. | FES counters | 5636 |
| Table 997. | ETHSW register map and reset values | 5705 |
| Table 998. | Memory map for ACM configuration | 5745 |
| Table 999. | HDP signal muxing | 5747 |
| Table 1000. | HDP register map and reset values | 5751 |
| Table 1001. | Key internal signals | 5755 |
| Table 1002. | SERF resources mapping | 5760 |
| Table 1003. | SERC register map and reset values | 5772 |
| Table 1004. | JTAG/Serial-wire debug port pins | 5777 |
| Table 1005. | Trace port pins | 5777 |
| Table 1006. | Serial-wire trace port pins | 5777 |
| Table 1007. | Trigger pins | 5777 |
| Table 1008. | Cortex-M0+ serial wire debug port pins | 5777 |
| Table 1009. | Authentication signal connectivity | 5780 |
| Table 1010. | Authentication signal initial states | 5781 |
| Table 1011. | CLTAPC registers | 5782 |
| Table 1012. | AP0 (Debug APB) authentication behavior | 5784 |
| Table 1013. | AP1-2-4-8 authentication behavior | 5784 |
| Table 1014. | Debug subsystem ROM table | 5785 |
| Table 1015. | Cortex-A35 subsystem ROM table | 5786 |
| Table 1016. | Trace subsystem CTI_0 inputs | 5791 |
| Table 1017. | Trace subsystem CTI_0 outputs | 5791 |
| Table 1018. | Trace subsystem CTI_1 inputs | 5792 |
| Table 1019. | Trace subsystem CTI_1 outputs | 5792 |
| Table 1020. | Cortex-A35_0/1 CTI inputs | 5792 |
| Table 1021. | Cortex-A35_0/1 CTI outputs | 5793 |
| Table 1022. | Cortex-M33 CTI inputs | 5793 |
| Table 1023. | Cortex-M33 CTI outputs | 5793 |
| Table 1024. Cortex-M0+ CTI inputs . . . . . | 5794 |
| Table 1025. Cortex-M0+ CTI outputs . . . . . | 5794 |
| Table 1026. Replicator allocation . . . . . | 5799 |
| Table 1027. STM extended stimulus port memory map . . . . . | 5801 |
| Table 1028. STM trace packet ID mapping to AXI masters . . . . . | 5801 |
| Table 1029. Hardware event mapping 0 to 3 . . . . . | 5802 |
| Table 1030. Hardware event mapping 4 to 7 . . . . . | 5804 |
| Table 1031. Hardware event mapping 8 to 9 . . . . . | 5806 |
| Table 1032. IWDG1 behavior in debug . . . . . | 5809 |
| Table 1033. DBGMCU register map and reset values . . . . . | 5825 |
| Table 1034. Cortex-M33 CPU ROM table . . . . . | 5830 |
| Table 1035. Cortex-M0+ integration level ROM table. . . . . | 5834 |
| Table 1036. Cortex-M0+ processor ROM table . . . . . | 5834 |
| Table 1037. Document revision history . . . . . | 5842 |
List of figures
| Figure 1. | STM32MP23/25xx interconnect top view | 213 |
| Figure 2. | STNoC-based MPU-side AXI interconnect | 219 |
| Figure 3. | STNoC internal router distribution (request path) and frequency distribution | 220 |
| Figure 4. | MLAHB interconnect for STM32MP23/25xx | 224 |
| Figure 5. | Memory map | 229 |
| Figure 6. | Cortex-M33 sub-system | 279 |
| Figure 7. | Cortex-M0+ implementation | 284 |
| Figure 8. | RIF principle | 288 |
| Figure 9. | RIF block diagram | 288 |
| Figure 10. | RIF access control principle | 290 |
| Figure 11. | Accesses to secure memories and peripherals | 291 |
| Figure 12. | Accesses to secure memories and peripherals | 291 |
| Figure 13. | RIF interrupt connection types | 292 |
| Figure 14. | Trusted domain chaining principle | 295 |
| Figure 15. | Wake-up CPU principle | 297 |
| Figure 16. | BSEC block diagram | 300 |
| Figure 17. | BSEC fuse mapping overview | 302 |
| Figure 18. | Device typical lifecycle | 303 |
| Figure 19. | RIMU block diagram (without inheritance) | 350 |
| Figure 20. | RIMU block diagram (with inheritance from RISUP programming) | 351 |
| Figure 21. | RISUP block diagram | 352 |
| Figure 22. | RISAL block diagram | 352 |
| Figure 23. | DAP and its RIMU | 355 |
| Figure 24. | Allocation of RISUP resources | 355 |
| Figure 25. | RISUP initialization principle | 357 |
| Figure 26. | RISAL region programming | 358 |
| Figure 27. | RISAL initialization principle | 359 |
| Figure 28. | RISAB block diagram | 376 |
| Figure 29. | RISAB region programming overview | 377 |
| Figure 30. | RISAB initialization principle | 378 |
| Figure 31. | RISAF block diagram (without DDRMCE) | 394 |
| Figure 32. | RISAF4 block diagram (with DDRMCE) | 394 |
| Figure 33. | RISAF region programming | 395 |
| Figure 34. | RISAF initialization principle | 398 |
| Figure 35. | RISAF region on-the-fly resizing | 399 |
| Figure 36. | IAC block diagram | 419 |
| Figure 37. | DDRSS top-level diagram | 427 |
| Figure 38. | ClkSwitcher architecture view | 429 |
| Figure 39. | AC-swizzling muxing stage | 431 |
| Figure 40. | Observability infrastructure organization | 434 |
| Figure 41. | Clock gating the DDRCTRL core clk in automatic self-refresh | 435 |
| Figure 42. | DDRCTRL block diagram | 449 |
| Figure 43. | Quasi-dynamic register programming | 457 |
| Figure 44. | DDRPHYC block diagram | 570 |
| Figure 45. | ACX4 component organization | 574 |
| Figure 46. | PHY clocking distribution | 575 |
| Figure 47. | DDRSS boot sequence | 576 |
| Figure 48. | DDRPERFM top view | 741 |
| Figure 49. | ICACHE block diagram | 795 |
| Figure 50. | ICACHE TAG and data memories functional view | 797 |
| Figure 51. | ICACHE remapping address mechanism | 800 |
| Figure 52. | DCACHE block diagram | 816 |
| Figure 53. | DCACHE TAG and data memories functional view | 819 |
| Figure 54. | Power control block diagram | 836 |
| Figure 55. | Power supply overview | 839 |
| Figure 56. | Device startup supply sequence | 842 |
| Figure 57. | Device Run2 supply sequence | 843 |
| Figure 58. | Device low-power Stop1 supply sequence | 844 |
| Figure 59. | Device low-power Stop2 supply sequence | 845 |
| Figure 60. | Device low-power LP-Stop1/LPLV-Stop1 supply sequence | 846 |
| Figure 61. | Device low-power LP-Stop2/LPLV-Stop2 supply sequence | 847 |
| Figure 62. | Device Standby mode power control | 848 |
| Figure 63. | Device Standby mode power control CPU2 wake-up alone | 848 |
| Figure 64. | Device VBAT mode power control | 849 |
| Figure 65. | Backup domain | 850 |
| Figure 66. | VDD domain | 853 |
| Figure 67. | Power-on reset/power-down reset waveform | 854 |
| Figure 68. | BOR thresholds | 855 |
| Figure 69. | vddcore_ok reset thresholds | 856 |
| Figure 70. | VDDCORE monitoring | 856 |
| Figure 71. | vddcpu_ok reset thresholds | 857 |
| Figure 72. | VDDCPU monitoring | 858 |
| Figure 73. | PVD thresholds | 859 |
| Figure 74. | V08CAP thresholds | 862 |
| Figure 75. | Temperature thresholds | 863 |
| Figure 76. | Power states and external regulator control | 874 |
| Figure 77. | Detailed state diagram of power control modes | 875 |
| Figure 78. | VBAT state diagram with TAMP_WKUEN_D3 = 1 | 894 |
| Figure 79. | PWR_CPU_ON, PWR_ON and PWR_LP multiplexing | 895 |
| Figure 80. | RCC block diagram | 942 |
| Figure 81. | System reset circuit | 945 |
| Figure 82. | NRST reset pulse control | 950 |
| Figure 83. | NRSTC1MS reset pulse control | 951 |
| Figure 84. | Reset source registers | 955 |
| Figure 85. | Boot sequences versus system states | 958 |
| Figure 86. | HOLD_BOOT CPUx reset | 961 |
| Figure 87. | HOLD_BOOT state in legacy mode | 962 |
| Figure 88. | HOLD_BOOT state in wake-up single event mode | 962 |
| Figure 89. | HOLD_BOOT state in wake-up dual event mode | 963 |
| Figure 90. | Top-level clock tree | 965 |
| Figure 91. | HSE clock source | 967 |
| Figure 92. | HSE clock generation | 968 |
| Figure 93. | HSI calibration flow | 970 |
| Figure 94. | MSI calibration flow | 971 |
| Figure 95. | LSE clock generation | 971 |
| Figure 96. | LSE CSS function | 975 |
| Figure 97. | MCOy clock observation | 976 |
| Figure 98. | PLL block diagram | 977 |
| Figure 99. | PLL with SSMOD (spread-spectrum modulator) configuration | 977 |
| Figure 100. | Spread-spectrum modulation | 980 |
| Figure 101. | Flexclkgen block diagram . . . . . | 982 |
| Figure 102. | Flexclkgen programming flow . . . . . | 983 |
| Figure 103. | Root control module description. . . . . | 986 |
| Figure 104. | Clock restore activation versus system mode. . . . . | 991 |
| Figure 105. | Clock restore process activated after system Stop. . . . . | 993 |
| Figure 106. | Wake-up from CStop . . . . . | 994 |
| Figure 107. | Peripheral clock distribution for TIMs . . . . . | 999 |
| Figure 108. | Peripheral clock distribution for ADCs . . . . . | 1000 |
| Figure 109. | Clock distribution for the DDR subsystem . . . . . | 1001 |
| Figure 110. | Entering and exiting self-refresh in ASR mode . . . . . | 1006 |
| Figure 111. | Entering and exiting self-refresh in HSR mode . . . . . | 1007 |
| Figure 112. | Allowed transitions between SSR, ASR and HSR modes . . . . . | 1008 |
| Figure 113. | Peripheral allocation example. . . . . | 1013 |
| Figure 114. | Peripheral clock enable logic details. . . . . | 1017 |
| Figure 115. | CPU1 low-power interface . . . . . | 1022 |
| Figure 116. | CPU1 PLL1 stop sequence . . . . . | 1022 |
| Figure 117. | D3 state description . . . . . | 1028 |
| Figure 118. | FMC interface clocking . . . . . | 1030 |
| Figure 119. | OCTOSPI interface clocking. . . . . | 1031 |
| Figure 120. | SDMMC interface clocking . . . . . | 1033 |
| Figure 121. | Single GMAC clocking . . . . . | 1035 |
| Figure 122. | ETHSWRAP schematic . . . . . | 1036 |
| Figure 123. | PCIE clock schematic. . . . . | 1040 |
| Figure 124. | CA35SS clock tree . . . . . | 1044 |
| Figure 125. | Camera part clocking schematic. . . . . | 1047 |
| Figure 126. | Display subsystem clocking schematic. . . . . | 1049 |
| Figure 127. | DPHY_PLL_X4TX details . . . . . | 1050 |
| Figure 128. | Open LVDS display interface (OLDI) clock details . . . . . | 1051 |
| Figure 129. | OLDI_DUAL_TX_4L details . . . . . | 1051 |
| Figure 130. | VENC and VDEC clocking schematic. . . . . | 1053 |
| Figure 131. | GPU and NPU subsystem clocking schematic. . . . . | 1054 |
| Figure 132. | USB2 host port clocking . . . . . | 1055 |
| Figure 133. | USB3 DRD port clocking . . . . . | 1057 |
| Figure 134. | USB Type-C and power delivery clocking . . . . . | 1060 |
| Figure 135. | Interrupt block diagram . . . . . | 1062 |
| Figure 136. | RCC RIF description. . . . . | 1068 |
| Figure 137. | HSEM block diagram . . . . . | 1307 |
| Figure 138. | Procedure state diagram . . . . . | 1308 |
| Figure 139. | Interrupt state diagram . . . . . | 1312 |
| Figure 140. | HSEM example - Secure unprivileged CID n . . . . . | 1316 |
| Figure 141. | HSEM example - Privileged CID m and n. . . . . | 1317 |
| Figure 142. | HSEM example - AHB bus master IDs. . . . . | 1318 |
| Figure 143. | IPCC block diagram . . . . . | 1343 |
| Figure 144. | IPCC Simplex channel mode transfer timing . . . . . | 1344 |
| Figure 145. | IPCC Simplex - Send procedure state diagram . . . . . | 1345 |
| Figure 146. | IPCC Simplex - Receive procedure state diagram . . . . . | 1346 |
| Figure 147. | IPCC Half-duplex channel mode transfer timing. . . . . | 1347 |
| Figure 148. | IPCC Half-duplex - Send procedure state diagram . . . . . | 1347 |
| Figure 149. | IPCC Half-duplex - Receive procedure state diagram . . . . . | 1348 |
| Figure 150. | Basic structure of an I/O port bit . . . . . | 1369 |
| Figure 151. | Input floating/pull-up/pull-down configurations . . . . . | 1373 |
| Figure 152. | Output configuration . . . . . | 1373 |
| Figure 153. Alternate function configuration | 1374 |
| Figure 154. Programmable analog configuration | 1375 |
| Figure 155. I/O compensation cell control overview | 1406 |
| Figure 156. HPDMA block diagram | 1529 |
| Figure 157. HPDMA channel direct programming without linked-list (HPDMA_CxLLR = 0) | 1530 |
| Figure 158. HPDMA channel suspend and resume sequence | 1531 |
| Figure 159. HPDMA channel abort and restart sequence | 1532 |
| Figure 160. Static linked-list data structure (all Uxx = 1) of a linear addressing channel x | 1533 |
| Figure 161. Static linked-list data structure (all Uxx = 1) of a 2D addressing channel x | 1534 |
| Figure 162. HPDMA dynamic linked-list data structure of linear addressing channel x | 1535 |
| Figure 163. HPDMA dynamic linked-list data structure of a 2D addressing channel x | 1535 |
| Figure 164. HPDMA channel execution and linked-list programming in run-to-completion mode (HPDMA_CxCR.LSM = 0) | 1538 |
| Figure 165. Inserting a LLIn with an auxiliary HPDMA channel y | 1540 |
| Figure 166. HPDMA channel execution and linked-list programming in link step mode (HPDMA_CxCR.LSM = 1) | 1542 |
| Figure 167. Building LLIn+1: HPDMA dynamic linked-lists in link step mode | 1543 |
| Figure 168. Replace with a new LLIn' in register file in link step mode | 1544 |
| Figure 169. Replace with a new LLIn' and LLIn+1' in memory in link step mode (option 1) | 1545 |
| Figure 170. Replace with a new LLIn' and LLIn+1' in memory in link step mode (option 2) | 1546 |
| Figure 171. HPDMA channel execution and linked-list programming | 1548 |
| Figure 172. Programmed 2D addressing | 1551 |
| Figure 173. HPDMA arbitration policy | 1566 |
| Figure 174. Trigger hit, memorization and overrun waveform | 1570 |
| Figure 175. HPDMA circular buffer programming: update of the memory start address with a linear addressing channel | 1571 |
| Figure 176. Shared HPDMA channel with circular buffering: update of the memory start address with a linear addressing channel | 1572 |
| Figure 177. LPDMA block diagram | 1639 |
| Figure 178. LPDMA channel direct programming without linked-list (LPDMA_CxLLR = 0) | 1640 |
| Figure 179. LPDMA channel suspend and resume sequence | 1641 |
| Figure 180. LPDMA channel abort and restart sequence | 1642 |
| Figure 181. Static linked-list data structure (all Uxx = 1) of channel x | 1643 |
| Figure 182. LPDMA dynamic linked-list data structure of an addressing channel x | 1644 |
| Figure 183. LPDMA channel execution and linked-list programming in run-to-completion mode (LPDMA_CxCR.LSM = 0) | 1646 |
| Figure 184. Inserting a LLIn with an auxiliary LPDMA channel y | 1648 |
| Figure 185. LPDMA channel execution and linked-list programming in link step mode (LPDMA_CxCR.LSM = 1) | 1650 |
| Figure 186. Building LLIn+1: LPDMA dynamic linked-lists in link step mode | 1651 |
| Figure 187. Replace with a new LLIn' in register file in link step mode | 1652 |
| Figure 188. Replace with a new LLIn' and LLIn+1' in memory in link step mode (option 1) | 1653 |
| Figure 189. Replace with a new LLIn' and LLIn+1' in memory in link step mode (option 2) | 1654 |
| Figure 190. LPDMA channel execution and linked-list programming | 1656 |
| Figure 191. LPDMA arbitration policy | 1660 |
| Figure 192. Trigger hit, memorization and overrun waveform | 1664 |
| Figure 193. LPDMA circular buffer programming: update of the memory start address | 1665 |
| Figure 194. Shared LPDMA channel with circular buffering: update of the memory start address | 1666 |
| Figure 195. GPU main blocks | 1715 |
| Figure 196. GPU clocks | 1716 |
| Figure 197. GIC block diagram (example with two cores/processors) | 1762 |
| Figure 198. | EXTI block diagram | 1809 |
| Figure 199. | Configurable event trigger logic CPU wake-up | 1817 |
| Figure 200. | Direct event trigger logic CPU wake-up | 1818 |
| Figure 201. | EXTI mux GPIO selection | 1819 |
| Figure 202. | CRC calculation unit block diagram | 1920 |
| Figure 203. | FMC interface block diagram | 1929 |
| Figure 204. | FMC interface reset | 1929 |
| Figure 205. | Octo-SPI interface block diagram | 1931 |
| Figure 206. | OCTOSPI interface resets | 1932 |
| Figure 207. | Programmable delay block diagram | 1935 |
| Figure 208. | Flash configuration example: 2x 8-bit flash devices controlled by OCTOSPI1 on port1 (MUXEN = 0, MODE = 0, CSSEL_OVR_EN = 0) | 1939 |
| Figure 209. | Flash configuration example: 2x 8-bit flash devices connected to port1 and controlled by independent OCTOSPI controllers (MUXEN = 1, MODE = 0, CSSEL_OVR_EN = 1, CSSEL_OVR_01 = 0, CSSEL_OVR_02 = 1) | 1941 |
| Figure 210. | Flash configuration example: dual quad mode. Two 4-bit devices are connected to port 2 and controlled by OCTOSPI2 (MUXEN = 0, MODE = 0, CSSEL_OVR_EN = 0) | 1942 |
| Figure 211. | SD/eMMC interface block diagram | 1948 |
| Figure 212. | SD/eMMC interface resets | 1949 |
| Figure 213. | FMC block diagram | 1957 |
| Figure 214. | Mode 1 read access waveforms | 1976 |
| Figure 215. | Mode 1 write access waveforms | 1976 |
| Figure 216. | Mode A read access waveforms | 1978 |
| Figure 217. | Mode A write access waveforms | 1979 |
| Figure 218. | Mode 2 and mode B read access waveforms | 1981 |
| Figure 219. | Mode 2 write access waveforms | 1981 |
| Figure 220. | Mode B write access waveforms | 1982 |
| Figure 221. | Mode C read access waveforms | 1984 |
| Figure 222. | Mode C write access waveforms | 1984 |
| Figure 223. | Mode D read access waveforms | 1986 |
| Figure 224. | Mode D write access waveforms | 1987 |
| Figure 225. | Muxed read access waveforms | 1989 |
| Figure 226. | Muxed write access waveforms | 1990 |
| Figure 227. | Asynchronous wait during a read access waveforms | 1993 |
| Figure 228. | Asynchronous wait during a write access waveforms | 1993 |
| Figure 229. | Wait configuration waveforms | 1995 |
| Figure 230. | Synchronous multiplexed read mode waveforms - NOR, PSRAM (CRAM) | 1996 |
| Figure 231. | Synchronous multiplexed write mode waveforms - PSRAM (CRAM) | 1998 |
| Figure 232. | NAND flash controller waveforms for common memory access | 2016 |
| Figure 233. | NAND flash controller waveforms for TCLR and TAR timings | 2016 |
| Figure 234. | Access to NAND flash memory | 2018 |
| Figure 235. | NAND flash page (2 Kbytes) layout with BCH | 2022 |
| Figure 236. | Example of 2 Kbyte page program sequence with 4-bit BCH | 2023 |
| Figure 237. | Chained-page read command timings | 2025 |
| Figure 238. | Example of 2-Kbyte page read sequence with 4-bit BCH | 2026 |
| Figure 239. | OCTOSPI block diagram in octal configuration | 2060 |
| Figure 240. | OCTOSPI block diagram in quad configuration | 2060 |
| Figure 241. | OCTOSPI block diagram in dual-quad configuration | 2061 |
| Figure 242. | SDR read command in octal configuration | 2063 |
| Figure 243. | DTR read in octal-SPI mode with DQS (Macronix mode) example | 2066 |
| Figure 244. | SDR write command in octo-SPI mode example | 2068 |
| Figure 245. DTR write in octal-SPI mode (Macronix mode) example ..... | 2068 |
| Figure 246. Example of HyperBus read operation ..... | 2070 |
| Figure 247. HyperBus write operation with initial latency ..... | 2071 |
| Figure 248. HyperBus read operation with additional latency ..... | 2072 |
| Figure 249. HyperBus write operation with additional latency ..... | 2072 |
| Figure 250. HyperBus write operation with no latency (register write) ..... | 2073 |
| Figure 251. HyperBus read operation page crossing with latency ..... | 2073 |
| Figure 252. D0/D1 data ordering in octal-SPI DTR mode (Micron) - Read access ..... | 2080 |
| Figure 253. OctaRAM read operation with reverse data ordering D1/D0 ..... | 2080 |
| Figure 254. NCS when CKMODE = 0 (T = CLK period) ..... | 2086 |
| Figure 255. NCS when CKMODE = 1 in SDR mode (T = CLK period) ..... | 2086 |
| Figure 256. NCS when CKMODE = 1 in DTR mode (T = CLK period) ..... | 2086 |
| Figure 257. NCS when CKMODE = 1 with an abort (T = CLK period) ..... | 2087 |
| Figure 258. Example of software control of two external memories ..... | 2087 |
| Figure 259. OCTOSPI block diagram ..... | 2119 |
| Figure 260. OCTOSPI direct mode ..... | 2121 |
| Figure 261. OCTOSPI swapped mode ..... | 2122 |
| Figure 262. OCTOSPI multiplexed mode to Port 1 ..... | 2123 |
| Figure 263. OCTOSPI multiplexed mode to Port 2 ..... | 2123 |
| Figure 264. OCTOSPI1 and OCTOSPI2 drive a single external memory ..... | 2124 |
| Figure 265. Single OCTOSPI driving two external memories ..... | 2125 |
| Figure 266. SDMMC “no response” and “no data” operations ..... | 2131 |
| Figure 267. SDMMC (multiple) block read operation ..... | 2131 |
| Figure 268. SDMMC (multiple) block write operation ..... | 2132 |
| Figure 269. SDMMC (sequential) stream read operation ..... | 2132 |
| Figure 270. SDMMC (sequential) stream write operation ..... | 2132 |
| Figure 271. SDMMC block diagram ..... | 2134 |
| Figure 272. SDMMC Command and data phase relation ..... | 2136 |
| Figure 273. Control unit ..... | 2138 |
| Figure 274. Command/response path ..... | 2139 |
| Figure 275. Command path state machine (CPSM) ..... | 2140 |
| Figure 276. Data path ..... | 2146 |
| Figure 277. DDR mode data packet clocking ..... | 2147 |
| Figure 278. DDR mode CRC status / boot acknowledgment clocking ..... | 2147 |
| Figure 279. Data path state machine (DPSM) ..... | 2148 |
| Figure 280. CLKMUX unit ..... | 2159 |
| Figure 281. Linked list structures ..... | 2162 |
| Figure 282. Asynchronous interrupt generation ..... | 2165 |
| Figure 283. Synchronous interrupt period data read ..... | 2166 |
| Figure 284. Synchronous interrupt period data write ..... | 2166 |
| Figure 285. Asynchronous interrupt period data read ..... | 2167 |
| Figure 286. Asynchronous interrupt period data write ..... | 2168 |
| Figure 287. Clock stop with SDMMC_CK for DS, HS, SDR12, SDR25 ..... | 2171 |
| Figure 288. Clock stop with SDMMC_CK for DDR50, SDR50, SDR104 ..... | 2171 |
| Figure 289. Read Wait with SDMMC_CK < 50 MHz ..... | 2172 |
| Figure 290. Read Wait with SDMMC_CK > 50 MHz ..... | 2172 |
| Figure 291. CMD12 stream timing ..... | 2175 |
| Figure 292. CMD5 Sleep Awake procedure ..... | 2177 |
| Figure 293. Normal boot mode operation ..... | 2179 |
| Figure 294. Alternative boot mode operation ..... | 2180 |
| Figure 295. Command response R1b busy signaling ..... | 2181 |
| Figure 296. SDMMC state control ..... | 2182 |
| Figure 297. Card cycle power / power up diagram ..... | 2183 |
| Figure 298. Read block gap hardware flow timing ..... | 2184 |
| Figure 299. CMD11 signal voltage switch sequence ..... | 2186 |
| Figure 300. Voltage switch transceiver typical application ..... | 2188 |
| Figure 301. DLYB block diagram ..... | 2218 |
| Figure 302. ADC block diagram ..... | 2226 |
| Figure 303. ADC clock scheme ..... | 2232 |
| Figure 304. ADC1 connectivity ..... | 2234 |
| Figure 305. ADC2 connectivity ..... | 2235 |
| Figure 306. ADC3 connectivity ..... | 2236 |
| Figure 307. Enabling / disabling the ADC ..... | 2240 |
| Figure 308. Bulb mode timing diagram ..... | 2244 |
| Figure 309. Analog-to-digital conversion time ..... | 2247 |
| Figure 310. Stopping ongoing regular conversions ..... | 2248 |
| Figure 311. Stopping ongoing regular and injected conversions ..... | 2249 |
| Figure 312. Triggers shared between ADC master and slave ..... | 2250 |
| Figure 313. Injected conversion latency ..... | 2252 |
| Figure 314. Single conversions of a sequence, software trigger ..... | 2255 |
| Figure 315. Continuous conversion of a sequence, software trigger ..... | 2255 |
| Figure 316. Single conversions of a sequence, hardware trigger ..... | 2256 |
| Figure 317. Continuous conversions of a sequence, hardware trigger ..... | 2256 |
| Figure 318. Right alignment (offset disabled, unsigned value) ..... | 2258 |
| Figure 319. Right alignment (offset enabled, signed value) ..... | 2259 |
| Figure 320. Left alignment (offset disabled, unsigned value) ..... | 2259 |
| Figure 321. Left alignment (offset enabled, signed value) ..... | 2260 |
| Figure 322. Example of overrun (OVRMOD = 0) ..... | 2263 |
| Figure 323. Example of overrun (OVRMOD = 1) ..... | 2263 |
| Figure 324. AUTODLY = 1, regular conversion in continuous mode, software trigger ..... | 2267 |
| Figure 325. AUTODLY = 1, regular hardware conversions interrupted by injected conversions (DISCEN = 0; JDISCEN = 0) ..... | 2268 |
| Figure 326. AUTODLY = 1, regular hardware conversions interrupted by injected conversions ..... | 2269 |
| Figure 327. AUTODLY = 1, regular continuous conversions interrupted by injected conversions ..... | 2269 |
| Figure 328. AUTODLY = 1 in autoinjection mode (JAUTO = 1) ..... | 2270 |
| Figure 329. Analog watchdog guarded area ..... | 2270 |
| Figure 330. ADC_AWDy_OUT signal generation (on all regular channels) ..... | 2273 |
| Figure 331. ADC_AWDy_OUT signal generation (AWDy flag not cleared by software) ..... | 2273 |
| Figure 332. ADC_AWDy_OUT signal generation (on a single regular channel) ..... | 2274 |
| Figure 333. ADC_AWDy_OUT signal generation (on all injected channels) ..... | 2274 |
| Figure 334. 12-bit result oversampling with 10-bit right shift and rounding ..... | 2275 |
| Figure 335. Triggered regular oversampling mode (TROVS bit = 1) ..... | 2277 |
| Figure 336. Regular oversampling modes (4x ratio) ..... | 2278 |
| Figure 337. Regular and injected oversampling modes used simultaneously ..... | 2279 |
| Figure 338. Triggered regular oversampling with injection ..... | 2279 |
| Figure 339. Oversampling in autoinjection mode ..... | 2280 |
| Figure 340. VBAT channel block diagram ..... | 2282 |
| Figure 341. VREFINT channel block diagram ..... | 2282 |
| Figure 342. DTS block diagram ..... | 2325 |
| Figure 343. Serial data adapter ..... | 2327 |
| Figure 344. SDA data format ..... | 2328 |
| Figure 345. Falling alarms ..... | 2334 |
| Figure 346. Rising alarms ..... | 2335 |
| Figure 347. VREFBUF block diagram ..... | 2363 |
| Figure 348. MDF block diagram ..... | 2371 |
| Figure 349. SITFx overview ..... | 2374 |
| Figure 350. SPI timing example ..... | 2375 |
| Figure 351. Manchester timing example (SITFMOD = 11) ..... | 2377 |
| Figure 352. CKGEN overview ..... | 2380 |
| Figure 353. BSMX overview ..... | 2382 |
| Figure 354. SCD functional view ..... | 2383 |
| Figure 355. SCD timing example ..... | 2383 |
| Figure 356. DFLT overview ..... | 2385 |
| Figure 357. Programmable delay ..... | 2386 |
| Figure 358. CIC3 and CIC5 frequency response with decimation ratio = 32 ..... | 2388 |
| Figure 359. Reshape filter frequency response normalized (FRS / 2 = 1) ..... | 2393 |
| Figure 360. Out-of-limit detector thresholds ..... | 2396 |
| Figure 361. Trigger logic for DFLT and CKGEN ..... | 2398 |
| Figure 362. Asynchronous continuous mode (ACQMOD[2:0] = 0) ..... | 2399 |
| Figure 363. Asynchronous single-shot mode (ACQMOD[2:0] = 001) ..... | 2400 |
| Figure 364. Synchronous continuous mode (ACQMOD[2:0] = 010) ..... | 2401 |
| Figure 365. Synchronous single-shot mode (ACQMOD[2:0] = 011) ..... | 2402 |
| Figure 366. Window continuous mode (ACQMOD[2:0] = 100) ..... | 2403 |
| Figure 367. Snapshot mode example ..... | 2405 |
| Figure 368. Discard function example ..... | 2406 |
| Figure 369. Start sequence with DFLTEN, in continuous mode, audio configuration ..... | 2407 |
| Figure 370. Start sequence with trigger input, in continuous mode, motor configuration ..... | 2408 |
| Figure 371. Break interface simplified view ..... | 2409 |
| Figure 372. MDF_DFLTxD data format ..... | 2409 |
| Figure 373. Data re-synchronization ..... | 2410 |
| Figure 374. Data transfer in interleaved-transfer mode ..... | 2411 |
| Figure 375. Data path for interleaved- and independent-transfer modes ..... | 2413 |
| Figure 376. Example of overflow and transfer to memory ..... | 2414 |
| Figure 377. MDF interrupt interface ..... | 2417 |
| Figure 378. Sensor connection examples ..... | 2422 |
| Figure 379. Global frequency response ..... | 2423 |
| Figure 380. Detailed frequency response ..... | 2423 |
| Figure 381. Simplified DFLT view with gain information ..... | 2426 |
| Figure 382. ADF block diagram ..... | 2457 |
| Figure 383. SITF overview ..... | 2459 |
| Figure 384. SPI timing example ..... | 2460 |
| Figure 385. Manchester timing example (SITFMOD = 11) ..... | 2461 |
| Figure 386. CKGEN overview ..... | 2464 |
| Figure 387. BSMX overview ..... | 2466 |
| Figure 388. DFLT overview ..... | 2467 |
| Figure 389. Programmable delay ..... | 2468 |
| Figure 390. CIC4 and CIC5 frequency response with decimation ratio = 32 or 16 ..... | 2469 |
| Figure 391. Reshape filter frequency response normalized (FRS / 2 = 1) ..... | 2475 |
| Figure 392. Trigger logic for DFLT and CKGEN ..... | 2477 |
| Figure 393. Asynchronous continuous mode (ACQMOD[2:0] = 0) ..... | 2478 |
| Figure 394. Asynchronous single-shot mode (ACQMOD[2:0] = 001) ..... | 2479 |
| Figure 395. Synchronous continuous mode (ACQMOD[2:0] = 010) ..... | 2480 |
| Figure 396. Synchronous single-shot mode (ACQMOD[2:0] = 011) ..... | 2481 |
| Figure 397. Window continuous mode (ACQMOD[2:0] = 100) ..... | 2482 |
| Figure 398. Discard function example ..... | 2484 |
| Figure 399. Start sequence with DFLTEN, in continuous mode, audio configuration ..... | 2484 |
| Figure 400. SAD block diagram ..... | 2485 |
| Figure 401. SAD flow diagram ..... | 2487 |
| Figure 402. SAD timing diagram example ..... | 2493 |
| Figure 403. ADF_DFLTxD data format ..... | 2493 |
| Figure 404. Data re-synchronization ..... | 2494 |
| Figure 405. Example of overflow and transfer to memory ..... | 2495 |
| Figure 406. ADF interrupt interface ..... | 2498 |
| Figure 407. Sensor connection examples ..... | 2503 |
| Figure 408. Global frequency response ..... | 2503 |
| Figure 409. Detailed frequency response ..... | 2504 |
| Figure 410. Simplified DFLT view with gain information ..... | 2506 |
| Figure 411. SAD example working with SADMOD = 01 ..... | 2509 |
| Figure 412. SAD example working with SADMOD = 1x ..... | 2511 |
| Figure 413. Camera subsystem block diagram ..... | 2535 |
| Figure 414. Camera subsystem clock diagram ..... | 2536 |
| Figure 415. DCM block diagram ..... | 2543 |
| Figure 416. DCM signal waveforms ..... | 2544 |
| Figure 417. Timing diagram ..... | 2546 |
| Figure 418. Frame capture waveforms in snapshot mode ..... | 2548 |
| Figure 419. Frame capture waveforms in continuous grab mode ..... | 2549 |
| Figure 420. Coordinates and size of the window after cropping ..... | 2549 |
| Figure 421. Data capture waveforms ..... | 2550 |
| Figure 422. Pixel raster scan order ..... | 2551 |
| Figure 423. DCMIPP overview ..... | 2567 |
| Figure 424. DCMIPP block diagram ..... | 2571 |
| Figure 425. VC flow processed by one pipe ..... | 2588 |
| Figure 426. Two exclusive VC flows processed by one reconfigured pipe ..... | 2588 |
| Figure 427. Two overlapping VC flows processed by two pipes ..... | 2589 |
| Figure 428. Snapshot (CPTMODE = 1) and Continuous (CPTMODE = 0) capture modes ..... | 2590 |
| Figure 429. Pipe0 (dump) architecture overview ..... | 2592 |
| Figure 430. Pipe1 ISP architecture view ..... | 2596 |
| Figure 431. Block diagram ..... | 2613 |
| Figure 432. Downsize with coverage filtering ..... | 2616 |
| Figure 433. Pipe2 architecture overview ..... | 2620 |
| Figure 434. Use case: Pipe0 (statistics), Pipe1 (pixels) ..... | 2621 |
| Figure 435. Statistics and RGB data for single virtual channel data flow ..... | 2622 |
| Figure 436. Three pipes within a single virtual channel in CSI2 mode ..... | 2623 |
| Figure 437. Handling interleaved packet ..... | 2623 |
| Figure 438. Handling interleaved packets across two pixel pipes ..... | 2623 |
| Figure 439. Interlaced video (based on single pixel pipe) ..... | 2624 |
| Figure 440. Interlaced video (based on two pixel pipes) ..... | 2624 |
| Figure 441. 3D sensors (top-bottom) processed by two pixel pipes ..... | 2629 |
| Figure 442. CSI-2 Host block diagram ..... | 2759 |
| Figure 443. CSI-2 Host architecture ..... | 2760 |
| Figure 444. CSI-2 Host clock domain ..... | 2762 |
| Figure 445. Lane merger input and output (one data lane) ..... | 2763 |
| Figure 446. Lane merger input and output (two data lanes) ..... | 2763 |
| Figure 447. Data lane mapping ..... | 2763 |
| Figure 448. Low-level protocol overview ..... | 2764 |
| Figure 449. CSI2- long-packet structure for a D-PHY physical layer ..... | 2765 |
| Figure 450. Short-packet structure based on D-PHY physical layer ..... | 2765 |
| Figure 451. DATA ID structure in short or long packet format . . . . . | 2766 |
| Figure 452. Data interleaving using data type . . . . . | 2767 |
| Figure 453. Data interleaving using virtual channels . . . . . | 2768 |
| Figure 454. RAW6 (BPP6) input and output format . . . . . | 2769 |
| Figure 455. Raw7 (BPP7) input and output format . . . . . | 2770 |
| Figure 456. Raw8 (BPP8) input and output format . . . . . | 2771 |
| Figure 457. Raw 10 (BPP10) input and output format . . . . . | 2771 |
| Figure 458. Raw12 (BPP12) input/output format . . . . . | 2772 |
| Figure 459. Raw14 (BPP14) input format . . . . . | 2773 |
| Figure 460. Raw16 (BPP16) input/output format . . . . . | 2774 |
| Figure 461. PSSI block diagram . . . . . | 2820 |
| Figure 462. Top-level block diagram . . . . . | 2820 |
| Figure 463. Data enable in receive mode waveform diagram (CKPOL=0) . . . . . | 2824 |
| Figure 464. Data enable waveform diagram in transmit mode (CKPOL=0) . . . . . | 2824 |
| Figure 465. Ready in receive mode waveform diagram (CKPOL=0) . . . . . | 2825 |
| Figure 466. Bidirectional PSSI_DE/PSSI_RDY waveform . . . . . | 2826 |
| Figure 467. Bidirectional PSSI_DE/PSSI_RDY connection diagram . . . . . | 2826 |
| Figure 468. Display subsystem block diagram . . . . . | 2837 |
| Figure 469. Display subsystem clock diagram . . . . . | 2838 |
| Figure 470. Display RIF peripheral ID . . . . . | 2842 |
| Figure 471. LTDC block diagram . . . . . | 2852 |
| Figure 472. Layer window programmable parameters . . . . . | 2866 |
| Figure 473. Blending two layers . . . . . | 2866 |
| Figure 474. LTDC synchronous timings . . . . . | 2872 |
| Figure 475. LVDS block diagram . . . . . | 2925 |
| Figure 476. Data mapping and its multiplexer . . . . . | 2927 |
| Figure 477. LVDS JEIDA Data mapping . . . . . | 2928 |
| Figure 478. LVDS VESA data mapping . . . . . | 2928 |
| Figure 479. Link phase timing diagram . . . . . | 2929 |
| Figure 480. DSI block diagram . . . . . | 3034 |
| Figure 481. DSI Host architecture . . . . . | 3035 |
| Figure 482. Flow to update the LTDC interface configuration using shadow registers . . . . . | 3040 |
| Figure 483. Immediate update procedure . . . . . | 3041 |
| Figure 484. Configuration update during the transmission of a frame . . . . . | 3041 |
| Figure 485. Adapted command mode usage flow . . . . . | 3043 |
| Figure 486. 24 bpp APB pixel to byte organization . . . . . | 3047 |
| Figure 487. 18 bpp APB pixel to byte organization . . . . . | 3048 |
| Figure 488. 16 bpp APB pixel to byte organization . . . . . | 3048 |
| Figure 489. 12 bpp APB pixel to byte organization . . . . . | 3049 |
| Figure 490. 8 bpp APB pixel to byte organization . . . . . | 3049 |
| Figure 491. Timing of PRESP_TO after a bus-turn-around . . . . . | 3052 |
| Figure 492. Timing of PRESP_TO after a read request (HS or LP) . . . . . | 3053 |
| Figure 493. Timing of PRESP_TO after a write request (HS or LP) . . . . . | 3054 |
| Figure 494. Effect of prep mode at 1 . . . . . | 3055 |
| Figure 495. Command transmission periods within the image area . . . . . | 3056 |
| Figure 496. Transmission of commands on the last line of a frame . . . . . | 3056 |
| Figure 497. LPSIZE for non-burst with sync pulses . . . . . | 3058 |
| Figure 498. LPSIZE for burst or non-burst with sync events . . . . . | 3058 |
| Figure 499. VLPSIZE for non-burst with sync pulses . . . . . | 3059 |
| Figure 500. VLPSIZE for non-burst with sync events . . . . . | 3060 |
| Figure 501. VLPSIZE for burst mode . . . . . | 3060 |
| Figure 502. Location of LPSIZE and VLPSIZE in the image area . . . . . | 3061 |
| Figure 503. Clock lane and data lane in HS ..... | 3063 |
| Figure 504. Clock lane in HS and data lanes in LP ..... | 3063 |
| Figure 505. Clock lane and data lane in LP ..... | 3063 |
| Figure 506. Command transmission by the generic interface ..... | 3064 |
| Figure 507. Vertical color bar mode ..... | 3066 |
| Figure 508. Horizontal color bar mode ..... | 3066 |
| Figure 509. RGB888 BER testing pattern ..... | 3067 |
| Figure 510. Vertical pattern (103x15) ..... | 3068 |
| Figure 511. Horizontal pattern (103x15) ..... | 3068 |
| Figure 512. PLL block diagram ..... | 3070 |
| Figure 513. Error sources ..... | 3075 |
| Figure 514. Video packet transmission configuration flow diagram ..... | 3086 |
| Figure 515. Programming sequence to send a test pattern ..... | 3088 |
| Figure 516. Frame configuration registers ..... | 3089 |
| Figure 517. VENC block diagram ..... | 3153 |
| Figure 518. VDEC main blocks ..... | 3266 |
| Figure 519. RNG block diagram ..... | 3302 |
| Figure 520. NIST SP800-90B entropy source model ..... | 3303 |
| Figure 521. RNG initialization overview ..... | 3306 |
| Figure 522. SAES block diagram ..... | 3322 |
| Figure 523. Encryption/ decryption typical usage ..... | 3324 |
| Figure 524. Typical operation with authentication ..... | 3326 |
| Figure 525. Example of suspend mode management ..... | 3327 |
| Figure 526. ECB encryption ..... | 3328 |
| Figure 527. ECB decryption ..... | 3328 |
| Figure 528. CBC encryption ..... | 3329 |
| Figure 529. CBC decryption ..... | 3329 |
| Figure 530. Message construction in CTR mode ..... | 3332 |
| Figure 531. CTR encryption ..... | 3333 |
| Figure 532. Message construction in GCM ..... | 3334 |
| Figure 533. GCM authenticated encryption ..... | 3336 |
| Figure 534. Message construction in GMAC mode ..... | 3339 |
| Figure 535. GMAC authentication mode ..... | 3339 |
| Figure 536. Message construction in CCM mode ..... | 3340 |
| Figure 537. CCM mode authenticated encryption ..... | 3342 |
| Figure 538. Operation with wrapped keys for SAES in ECB and CBC modes ..... | 3345 |
| Figure 539. Operation with wrapped keys for SAES in CTR mode ..... | 3348 |
| Figure 540. Usage of Shared-key mode ..... | 3349 |
| Figure 541. 128-bit block construction according to the data type ..... | 3352 |
| Figure 542. Key protection mechanisms ..... | 3354 |
| Figure 543. CRYP block diagram ..... | 3379 |
| Figure 544. Encryption/ decryption typical usage ..... | 3381 |
| Figure 545. Typical operation with authentication ..... | 3384 |
| Figure 546. Example of suspend mode management ..... | 3385 |
| Figure 547. DES/TDES ECB encryption ..... | 3386 |
| Figure 548. DES/TDES ECB decryption ..... | 3386 |
| Figure 549. DES/TDES CBC encryption ..... | 3387 |
| Figure 550. DES/TDES CBC decryption ..... | 3387 |
| Figure 551. AES-ECB encryption ..... | 3389 |
| Figure 552. AES-ECB decryption ..... | 3390 |
| Figure 553. AES-CBC encryption ..... | 3390 |
| Figure 554. AES-CBC decryption ..... | 3391 |
| Figure 555. Message construction in CTR mode. .... | 3393 |
| Figure 556. AES-CTR encryption . . . . . | 3394 |
| Figure 557. Message construction in GCM . . . . . | 3396 |
| Figure 558. GCM authenticated encryption . . . . . | 3397 |
| Figure 559. Message construction in GMAC mode . . . . . | 3401 |
| Figure 560. GMAC authentication mode . . . . . | 3401 |
| Figure 561. Message construction in CCM mode . . . . . | 3402 |
| Figure 562. CCM mode authenticated encryption . . . . . | 3404 |
| Figure 563. 64-bit block construction according to the data type. .... | 3409 |
| Figure 564. 128-bit block construction according to the data type. .... | 3411 |
| Figure 565. HASH block diagram . . . . . | 3436 |
| Figure 566. Message data swapping feature. .... | 3439 |
| Figure 567. HASH suspend/resume mechanism. .... | 3445 |
| Figure 568. OTFDEC block diagram . . . . . | 3464 |
| Figure 569. Typical OTFDEC use in a SoC . . . . . | 3465 |
| Figure 570. AES CTR decryption flow . . . . . | 3466 |
| Figure 571. OTFDEC flow control overview (dual burst read request) . . . . . | 3467 |
| Figure 572. PKA block diagram . . . . . | 3486 |
| Figure 573. Advanced-control timer block diagram . . . . . | 3521 |
| Figure 574. Counter timing diagram with prescaler division change from 1 to 2 . . . . . | 3527 |
| Figure 575. Counter timing diagram with prescaler division change from 1 to 4 . . . . . | 3528 |
| Figure 576. Counter timing diagram, internal clock divided by 1 . . . . . | 3529 |
| Figure 577. Counter timing diagram, internal clock divided by 2 . . . . . | 3530 |
| Figure 578. Counter timing diagram, internal clock divided by 4 . . . . . | 3530 |
| Figure 579. Counter timing diagram, internal clock divided by N . . . . . | 3531 |
| Figure 580. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded). . . . . | 3531 |
| Figure 581. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded). . . . . | 3532 |
| Figure 582. Counter timing diagram, internal clock divided by 1 . . . . . | 3533 |
| Figure 583. Counter timing diagram, internal clock divided by 2 . . . . . | 3534 |
| Figure 584. Counter timing diagram, internal clock divided by 4 . . . . . | 3534 |
| Figure 585. Counter timing diagram, internal clock divided by N . . . . . | 3535 |
| Figure 586. Counter timing diagram, update event when repetition counter is not used. .... | 3535 |
| Figure 587. Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6 . . . . . | 3537 |
| Figure 588. Counter timing diagram, internal clock divided by 2 . . . . . | 3537 |
| Figure 589. Counter timing diagram, internal clock divided by 4, TIMx_ARR = 0x36 . . . . . | 3538 |
| Figure 590. Counter timing diagram, internal clock divided by N . . . . . | 3538 |
| Figure 591. Counter timing diagram, update event with ARPE = 1 (counter underflow) . . . . . | 3539 |
| Figure 592. Counter timing diagram, Update event with ARPE = 1 (counter overflow) . . . . . | 3540 |
| Figure 593. Update rate examples depending on mode and TIMx_RCR register settings . . . . . | 3541 |
| Figure 595. Control circuit in normal mode, internal clock divided by 1 . . . . . | 3543 |
| Figure 596. tim_ti2 external clock connection example . . . . . | 3543 |
| Figure 597. Control circuit in external clock mode 1 . . . . . | 3544 |
| Figure 598. External trigger input block . . . . . | 3545 |
| Figure 599. Control circuit in external clock mode 2 . . . . . | 3546 |
| Figure 600. Capture/compare channel (example: channel 1 input stage) . . . . . | 3546 |
| Figure 601. Capture/compare channel 1 main circuit . . . . . | 3547 |
| Figure 602. Output stage of capture/compare channel (channel 1, idem ch. 2, 3 and 4) . . . . . | 3547 |
| Figure 603. Output stage of capture/compare channel (channel 5, idem ch. 6) . . . . . | 3548 |
| Figure 604. PWM input mode timing . . . . . | 3550 |
| Figure 605. Output compare mode, toggle on tim_oc1 . . . . . | 3552 |
| Figure 606. | Edge-aligned PWM waveforms (ARR = 8) . . . . . | 3553 |
| Figure 607. | Center-aligned PWM waveforms (ARR = 8) . . . . . | 3554 |
| Figure 608. | Dithering principle . . . . . | 3555 |
| Figure 609. | Data format and register coding in dithering mode . . . . . | 3556 |
| Figure 610. | PWM resolution vs frequency . . . . . | 3557 |
| Figure 611. | PWM dithering pattern . . . . . | 3558 |
| Figure 612. | Dithering effect on duty cycle in center-aligned PWM mode . . . . . | 3559 |
| Figure 613. | Generation of 2 phase-shifted PWM signals with 50% duty cycle . . . . . | 3561 |
| Figure 614. | Combined PWM mode on channel 1 and 3 . . . . . | 3562 |
| Figure 615. | 3-phase combined PWM signals with multiple trigger pulses per period . . . . . | 3563 |
| Figure 616. | Complementary output with symmetrical dead-time insertion . . . . . | 3564 |
| Figure 617. | Asymmetrical deadtime . . . . . | 3565 |
| Figure 618. | Dead-time waveforms with delay greater than the negative pulse . . . . . | 3565 |
| Figure 619. | Dead-time waveforms with delay greater than the positive pulse . . . . . | 3565 |
| Figure 620. | Break and Break2 circuitry overview . . . . . | 3568 |
| Figure 621. | Various output behavior in response to a break event on tim_brk (OSSI = 1) . . . . . | 3570 |
| Figure 622. | PWM output state following tim_brk and tim_brk2 assertion (OSSI = 1) . . . . . | 3571 |
| Figure 623. | PWM output state following tim_brk assertion (OSSI = 0) . . . . . | 3572 |
| Figure 624. | Output redirection (tim_brk2 request not represented) . . . . . | 3573 |
| Figure 625. | Clearing TIMx tim_ocxref . . . . . | 3574 |
| Figure 626. | 6-step generation, COM example (OSSR = 1) . . . . . | 3575 |
| Figure 627. | Example of one pulse mode . . . . . | 3576 |
| Figure 628. | Retriggerable one-pulse mode . . . . . | 3578 |
| Figure 629. | Pulse generator circuitry . . . . . | 3578 |
| Figure 630. | Pulse generation on compare event, for edge-aligned and encoder modes . . . . . | 3579 |
| Figure 631. | Extended pulsewidth in case of concurrent triggers . . . . . | 3580 |
| Figure 632. | Example of counter operation in encoder interface mode . . . . . | 3582 |
| Figure 633. | Example of encoder interface mode with tim_ti1fp1 polarity inverted . . . . . | 3582 |
| Figure 634. | Quadrature encoder counting modes . . . . . | 3583 |
| Figure 635. | Direction plus clock encoder mode . . . . . | 3584 |
| Figure 636. | Directional clock encoder mode (CC1P = CC2P = 0) . . . . . | 3584 |
| Figure 637. | Directional clock encoder mode (CC1P = CC2P = 1) . . . . . | 3585 |
| Figure 638. | Index gating options . . . . . | 3586 |
| Figure 639. | Jittered Index signals . . . . . | 3586 |
| Figure 640. | Index generation for IPOS[1:0] = 11 . . . . . | 3587 |
| Figure 641. | Counter reading with index gated on channel A (IPOS[1:0] = 11) . . . . . | 3587 |
| Figure 642. | Counter reading with index ungated (IPOS[1:0] = 00) . . . . . | 3588 |
| Figure 643. | Counter reading with index gated on channel A and B . . . . . | 3588 |
| Figure 644. | Encoder mode behavior in case of narrow index pulse (IPOS[1:0] = 11) . . . . . | 3589 |
| Figure 645. | Counter reset Narrow index pulse (closer view, ARR = 0x07) . . . . . | 3590 |
| Figure 646. | Index behavior in x1 and x2 mode (IPOS[1:0] = 01) . . . . . | 3591 |
| Figure 647. | Directional index sensitivity . . . . . | 3591 |
| Figure 648. | Counter reset as function of FIDX bit setting . . . . . | 3592 |
| Figure 649. | Index blanking . . . . . | 3592 |
| Figure 650. | Index behavior in clock + direction mode, IPOS[0] = 1 . . . . . | 3593 |
| Figure 651. | Index behavior in directional clock mode, IPOS[0] = 1 . . . . . | 3593 |
| Figure 652. | State diagram for quadrature encoded signals . . . . . | 3594 |
| Figure 653. | Up-counting encoder error detection . . . . . | 3595 |
| Figure 654. | Down-counting encode error detection . . . . . | 3596 |
| Figure 655. | Encoder mode change with preload transferred on update (SMSPS = 0) . . . . . | 3597 |
| Figure 656. | Measuring time interval between edges on three signals . . . . . | 3598 |
| Figure 657. | Example of Hall sensor interface . . . . . | 3600 |
| Figure 658. | Control circuit in reset mode . . . . . | 3601 |
| Figure 659. | Control circuit in Gated mode . . . . . | 3602 |
| Figure 660. | Control circuit in trigger mode . . . . . | 3603 |
| Figure 661. | Control circuit in external clock mode 2 + trigger mode . . . . . | 3604 |
| Figure 662. | General-purpose timer block diagram . . . . . | 3666 |
| Figure 663. | Counter timing diagram with prescaler division change from 1 to 2 . . . . . | 3671 |
| Figure 664. | Counter timing diagram with prescaler division change from 1 to 4 . . . . . | 3672 |
| Figure 665. | Counter timing diagram, internal clock divided by 1 . . . . . | 3673 |
| Figure 666. | Counter timing diagram, internal clock divided by 2 . . . . . | 3673 |
| Figure 667. | Counter timing diagram, internal clock divided by 4 . . . . . | 3674 |
| Figure 668. | Counter timing diagram, internal clock divided by N . . . . . | 3674 |
| Figure 669. | Counter timing diagram, Update event when ARPE = 0 (TIMx_ARR not preloaded) . . . . . | 3675 |
| Figure 670. | Counter timing diagram, Update event when ARPE = 1 (TIMx_ARR preloaded) . . . . . | 3676 |
| Figure 671. | Counter timing diagram, internal clock divided by 1 . . . . . | 3677 |
| Figure 672. | Counter timing diagram, internal clock divided by 2 . . . . . | 3678 |
| Figure 673. | Counter timing diagram, internal clock divided by 4 . . . . . | 3678 |
| Figure 674. | Counter timing diagram, internal clock divided by N . . . . . | 3679 |
| Figure 675. | Counter timing diagram, Update event . . . . . | 3679 |
| Figure 676. | Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6 . . . . . | 3681 |
| Figure 677. | Counter timing diagram, internal clock divided by 2 . . . . . | 3681 |
| Figure 678. | Counter timing diagram, internal clock divided by 4, TIMx_ARR = 0x36 . . . . . | 3682 |
| Figure 679. | Counter timing diagram, internal clock divided by N . . . . . | 3682 |
| Figure 680. | Counter timing diagram, Update event with ARPE = 1 (counter underflow) . . . . . | 3683 |
| Figure 681. | Counter timing diagram, Update event with ARPE = 1 (counter overflow) . . . . . | 3684 |
| Figure 682. | Control circuit in normal mode, internal clock divided by 1 . . . . . | 3685 |
| Figure 683. | tim_ti2 external clock connection example . . . . . | 3685 |
| Figure 684. | Control circuit in external clock mode 1 . . . . . | 3686 |
| Figure 685. | External trigger input block . . . . . | 3687 |
| Figure 686. | Control circuit in external clock mode 2 . . . . . | 3688 |
| Figure 687. | Capture/compare channel (example: channel 1 input stage) . . . . . | 3688 |
| Figure 688. | Capture/compare channel 1 main circuit . . . . . | 3689 |
| Figure 689. | Output stage of capture/compare channel (channel 1, idem ch.2, 3 and 4) . . . . . | 3689 |
| Figure 690. | PWM input mode timing . . . . . | 3692 |
| Figure 691. | Output compare mode, toggle on tim_oc1 . . . . . | 3694 |
| Figure 692. | Edge-aligned PWM waveforms (ARR = 8) . . . . . | 3695 |
| Figure 693. | Center-aligned PWM waveforms (ARR = 8) . . . . . | 3696 |
| Figure 694. | Dithering principle . . . . . | 3697 |
| Figure 695. | Data format and register coding in dithering mode . . . . . | 3698 |
| Figure 696. | PWM resolution vs frequency (16-bit mode) . . . . . | 3699 |
| Figure 697. | PWM resolution vs frequency (32-bit mode) . . . . . | 3699 |
| Figure 698. | PWM dithering pattern . . . . . | 3700 |
| Figure 699. | Dithering effect on duty cycle in center-aligned PWM mode . . . . . | 3701 |
| Figure 700. | Generation of two phase-shifted PWM signals with 50% duty cycle . . . . . | 3703 |
| Figure 701. | Combined PWM mode on channels 1 and 3 . . . . . | 3704 |
| Figure 702. | OCREF_CLR input selection multiplexer . . . . . | 3705 |
| Figure 703. | Clearing TIMx tim_ocxref . . . . . | 3705 |
| Figure 704. | Example of One-pulse mode . . . . . | 3706 |
| Figure 705. | Retriggerable one-pulse mode . . . . . | 3708 |
| Figure 706. | Pulse generator circuitry . . . . . | 3709 |
| Figure 707. | Pulse generation on compare event, for edge-aligned and encoder modes . . . . . | 3709 |
| Figure 708. | Extended pulse width in case of concurrent triggers . . . . . | 3710 |
| Figure 709. | Example of counter operation in encoder interface mode . . . . . | 3712 |
| Figure 710. Example of encoder interface mode with tim_ti1fp1 polarity inverted | 3712 |
| Figure 711. Quadrature encoder counting modes | 3713 |
| Figure 712. Direction plus clock encoder mode | 3714 |
| Figure 713. Directional clock encoder mode (CC1P = CC2P = 0) | 3715 |
| Figure 714. Directional clock encoder mode (CC1P = CC2P = 1) | 3715 |
| Figure 715. Index gating options | 3717 |
| Figure 716. Jittered Index signals | 3717 |
| Figure 717. Index generation for IPOS[1:0] = 11 | 3718 |
| Figure 718. Counter reading with index gated on channel A (IPOS[1:0] = 11) | 3718 |
| Figure 719. Counter reading with index ungated (IPOS[1:0] = 00) | 3719 |
| Figure 720. Counter reading with index gated on channel A and B | 3719 |
| Figure 721. Encoder mode behavior in case of narrow index pulse (IPOS[1:0] = 11) | 3720 |
| Figure 722. Counter reset Narrow index pulse (closer view, ARR = 0x07) | 3721 |
| Figure 723. Index behavior in x1 and x2 mode (IPOS[1:0] = 01) | 3722 |
| Figure 724. Directional index sensitivity | 3722 |
| Figure 725. Counter reset as function of FIDX bit setting | 3723 |
| Figure 726. Index blanking | 3723 |
| Figure 727. Index behavior in clock + direction mode, IPOS[0] = 1 | 3724 |
| Figure 728. Index behavior in directional clock mode, IPOS[0] = 1 | 3724 |
| Figure 729. State diagram for quadrature encoded signals | 3725 |
| Figure 730. Up-counting encoder error detection | 3726 |
| Figure 731. Down-counting encode error detection | 3727 |
| Figure 732. Encoder mode change with preload transferred on update (SMSPS = 0) | 3728 |
| Figure 733. Control circuit in reset mode | 3730 |
| Figure 734. Control circuit in gated mode | 3731 |
| Figure 735. Control circuit in trigger mode | 3731 |
| Figure 736. Control circuit in external clock mode 2 + trigger mode | 3733 |
| Figure 737. Master/Slave timer example | 3733 |
| Figure 738. Master/slave connection example with 1 channel only timers | 3734 |
| Figure 739. Gating TIM_slv with tim_oc1ref of TIM_mstr | 3735 |
| Figure 740. Gating TIM_slv with Enable of TIM_mstr | 3736 |
| Figure 741. Triggering TIM_slv with update of TIM_mstr | 3737 |
| Figure 742. Triggering TIM_slv with Enable of TIM_mstr | 3737 |
| Figure 743. Triggering TIM_mstr and TIM_slv with TIM_mstr tim_ti1 input | 3738 |
| Figure 744. Basic timer block diagram | 3781 |
| Figure 745. Control circuit in normal mode, internal clock divided by 1 | 3782 |
| Figure 746. Counter timing diagram with prescaler division change from 1 to 2 | 3783 |
| Figure 747. Counter timing diagram with prescaler division change from 1 to 4 | 3784 |
| Figure 748. Counter timing diagram, internal clock divided by 1 | 3785 |
| Figure 749. Counter timing diagram, internal clock divided by 2 | 3785 |
| Figure 750. Counter timing diagram, internal clock divided by 4 | 3786 |
| Figure 751. Counter timing diagram, internal clock divided by N | 3786 |
| Figure 752. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded) | 3787 |
| Figure 753. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded) | 3788 |
| Figure 754. Dithering principle | 3789 |
| Figure 755. Data format and register coding in dithering mode | 3789 |
| Figure 756. FCnt resolution vs frequency | 3790 |
| Figure 757. PWM dithering pattern | 3790 |
| Figure 758. General-purpose timer block diagram (TIM12) | 3806 |
| Figure 759. General-purpose timer block diagram (TIM10/TIM11/TIM13/TIM14) | 3807 |
| Figure 760. Counter timing diagram with prescaler division change from 1 to 2 . . . . . | 3810 |
| Figure 761. Counter timing diagram with prescaler division change from 1 to 4 . . . . . | 3810 |
| Figure 762. Counter timing diagram, internal clock divided by 1 . . . . . | 3811 |
| Figure 763. Counter timing diagram, internal clock divided by 2 . . . . . | 3812 |
| Figure 764. Counter timing diagram, internal clock divided by 4 . . . . . | 3812 |
| Figure 765. Counter timing diagram, internal clock divided by N . . . . . | 3813 |
| Figure 766. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded) . . . . . | 3813 |
| Figure 767. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded) . . . . . | 3814 |
| Figure 768. Control circuit in normal mode, internal clock divided by 1 . . . . . | 3815 |
| Figure 769. tim_ti2 external clock connection example . . . . . | 3815 |
| Figure 770. Control circuit in external clock mode 1 . . . . . | 3816 |
| Figure 771. Capture/compare channel 1 input stage (TIM10/TIM11/TIM13/TIM14) . . . . . | 3817 |
| Figure 772. Capture/compare channel 1 input stage (TIM12) . . . . . | 3817 |
| Figure 773. Capture/compare channel 1 main circuit . . . . . | 3818 |
| Figure 774. Output stage of capture/compare channel 1 . . . . . | 3818 |
| Figure 775. PWM input mode timing . . . . . | 3820 |
| Figure 776. Output compare mode, toggle on tim_oc1 . . . . . | 3822 |
| Figure 777. Edge-aligned PWM waveforms (ARR = 8) . . . . . | 3823 |
| Figure 778. Dithering principle . . . . . | 3824 |
| Figure 779. Data format and register coding in dithering mode . . . . . | 3824 |
| Figure 780. PWM resolution vs frequency . . . . . | 3825 |
| Figure 781. PWM dithering pattern . . . . . | 3826 |
| Figure 782. Combined PWM mode on channel 1 and 2 . . . . . | 3828 |
| Figure 783. Example of one pulse mode . . . . . | 3829 |
| Figure 784. Retriggerable one pulse mode . . . . . | 3830 |
| Figure 785. Measuring time interval between edges on 2 signals . . . . . | 3831 |
| Figure 786. Control circuit in reset mode . . . . . | 3832 |
| Figure 787. Control circuit in gated mode . . . . . | 3833 |
| Figure 788. Control circuit in trigger mode . . . . . | 3833 |
| Figure 789. TIM15 block diagram . . . . . | 3876 |
| Figure 790. TIM16/TIM17 block diagram . . . . . | 3877 |
| Figure 791. Counter timing diagram with prescaler division change from 1 to 2 . . . . . | 3881 |
| Figure 792. Counter timing diagram with prescaler division change from 1 to 4 . . . . . | 3882 |
| Figure 793. Counter timing diagram, internal clock divided by 1 . . . . . | 3883 |
| Figure 794. Counter timing diagram, internal clock divided by 2 . . . . . | 3884 |
| Figure 795. Counter timing diagram, internal clock divided by 4 . . . . . | 3884 |
| Figure 796. Counter timing diagram, internal clock divided by N . . . . . | 3885 |
| Figure 797. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded) . . . . . | 3885 |
| Figure 798. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded) . . . . . | 3886 |
| Figure 799. Update rate examples depending on mode and TIMx_RCR register settings . . . . . | 3887 |
| Figure 800. Control circuit in normal mode, internal clock divided by 1 . . . . . | 3888 |
| Figure 801. tim_ti2 external clock connection example . . . . . | 3888 |
| Figure 802. Control circuit in external clock mode 1 . . . . . | 3889 |
| Figure 803. Capture/compare channel (example: channel 1 input stage) . . . . . | 3890 |
| Figure 804. Capture/compare channel 1 main circuit . . . . . | 3890 |
| Figure 805. Output stage of capture/compare channel (channel 1) . . . . . | 3891 |
| Figure 806. Output stage of capture/compare channel (channel 2 for TIM15) . . . . . | 3891 |
| Figure 807. PWM input mode timing . . . . . | 3894 |
| Figure 808. Output compare mode, toggle on tim_oc1 | 3896 |
| Figure 809. Edge-aligned PWM waveforms (ARR = 8) | 3897 |
| Figure 810. Dithering principle | 3898 |
| Figure 811. Data format and register coding in dithering mode | 3898 |
| Figure 812. PWM resolution vs frequency | 3899 |
| Figure 813. PWM dithering pattern | 3900 |
| Figure 814. Combined PWM mode on channel 1 and 2 | 3902 |
| Figure 815. Complementary output with symmetrical dead-time insertion | 3903 |
| Figure 816. Asymmetrical deadtime | 3904 |
| Figure 817. Dead-time waveforms with delay greater than the negative pulse | 3904 |
| Figure 818. Dead-time waveforms with delay greater than the positive pulse | 3904 |
| Figure 819. Break circuitry overview | 3906 |
| Figure 820. Output behavior in response to a break event on tim_brk | 3908 |
| Figure 821. Output redirection | 3910 |
| Figure 822. tim_ocref_clr input selection multiplexer | 3911 |
| Figure 823. 6-step generation, COM example (OSSR = 1) | 3912 |
| Figure 824. Example of one pulse mode | 3913 |
| Figure 825. Retriggerable one pulse mode | 3915 |
| Figure 826. Measuring time interval between edges on 2 signals | 3915 |
| Figure 827. Control circuit in reset mode | 3916 |
| Figure 828. Control circuit in gated mode | 3917 |
| Figure 829. Control circuit in trigger mode | 3918 |
| Figure 830. LPTIM1/2/3/4 block diagram(1) | 3989 |
| Figure 831. LPTIM5 block diagram(1) | 3990 |
| Figure 832. Glitch filter timing diagram | 3994 |
| Figure 833. LPTIM output waveform, single-counting mode configuration when repetition register content is different than zero (with PRELOAD = 1) | 3996 |
| Figure 834. LPTIM output waveform, single-counting mode configuration and Set-once mode activated (WAVE bit is set) | 3996 |
| Figure 835. LPTIM output waveform, Continuous counting mode configuration | 3997 |
| Figure 836. Waveform generation | 3998 |
| Figure 837. Encoder mode counting sequence | 4002 |
| Figure 838. Continuous counting mode when repetition register LPTIM_RCR different from zero (with PRELOAD = 1) | 4003 |
| Figure 839. Capture/compare input stage (channel 1) | 4004 |
| Figure 840. Capture/compare output stage (channel 1) | 4004 |
| Figure 841. Edge-aligned PWM mode (PRELOAD = 1) | 4006 |
| Figure 842. Edge-aligned PWM waveforms (ARR=8 and CCxP = 0) | 4007 |
| Figure 843. PWM mode with immediate update versus preloaded update | 4008 |
| Figure 844. STGEN block diagram | 4043 |
| Figure 845. Top view of independent watchdogs | 4060 |
| Figure 846. Windows watchdogs top view | 4061 |
| Figure 847. Independent watchdog block diagram | 4063 |
| Figure 848. Reset timing due to timeout | 4065 |
| Figure 849. Reset timing due to refresh in the not allowed area | 4066 |
| Figure 850. Changing PR, RL, and performing a refresh(1) | 4067 |
| Figure 851. Window comparator update(1) | 4068 |
| Figure 852. Independent watchdog interrupt timing diagram | 4070 |
| Figure 853. Early wake-up comparator update(1) | 4071 |
| Figure 854. Watchdog block diagram | 4081 |
| Figure 855. Window watchdog timing diagram | 4083 |
| Figure 856. RTC block diagram | 4091 |
| Figure 857. TAMP block diagram ..... | 4157 |
| Figure 858. Backup registers protection zones ..... | 4162 |
| Figure 859. Access rights for TAMP resources according to the CID ..... | 4165 |
| Figure 860. Tamper sampling with precharge pulse ..... | 4170 |
| Figure 861. Low level detection with precharge and filtering ..... | 4170 |
| Figure 862. Active tamper filtering ..... | 4172 |
| Figure 863. Block diagram ..... | 4218 |
| Figure 864. I2C-bus protocol ..... | 4220 |
| Figure 865. Setup and hold timings ..... | 4222 |
| Figure 866. I2C initialization flow ..... | 4224 |
| Figure 867. Data reception ..... | 4225 |
| Figure 868. Data transmission ..... | 4226 |
| Figure 869. Slave initialization flow ..... | 4229 |
| Figure 870. Transfer sequence flow for I2C slave transmitter, NOSTRETCH = 0 ..... | 4231 |
| Figure 871. Transfer sequence flow for I2C slave transmitter, NOSTRETCH = 1 ..... | 4232 |
| Figure 872. Transfer bus diagrams for I2C slave transmitter (mandatory events only) ..... | 4233 |
| Figure 873. Transfer sequence flow for I2C slave receiver, NOSTRETCH = 0 ..... | 4234 |
| Figure 874. Transfer sequence flow for I2C slave receiver, NOSTRETCH = 1 ..... | 4235 |
| Figure 875. Transfer bus diagrams for I2C slave receiver (mandatory events only) ..... | 4235 |
| Figure 876. Master clock generation ..... | 4237 |
| Figure 877. Master initialization flow ..... | 4239 |
| Figure 878. 10-bit address read access with HEAD10R = 0 ..... | 4239 |
| Figure 879. 10-bit address read access with HEAD10R = 1 ..... | 4240 |
| Figure 880. Transfer sequence flow for I2C master transmitter, N ≤ 255 bytes ..... | 4241 |
| Figure 881. Transfer sequence flow for I2C master transmitter, N > 255 bytes ..... | 4242 |
| Figure 882. Transfer bus diagrams for I2C master transmitter (mandatory events only) ..... | 4243 |
| Figure 883. Transfer sequence flow for I2C master receiver, N ≤ 255 bytes ..... | 4245 |
| Figure 884. Transfer sequence flow for I2C master receiver, N > 255 bytes ..... | 4246 |
| Figure 885. Transfer bus diagrams for I2C master receiver (mandatory events only) ..... | 4247 |
| Figure 886. Timeout intervals for tLOW:SEXT, tLOW:MEXT ..... | 4251 |
| Figure 887. Transfer sequence flow for SMBus slave transmitter N bytes + PEC ..... | 4254 |
| Figure 888. Transfer bus diagram for SMBus slave transmitter (SBC = 1) ..... | 4255 |
| Figure 889. Transfer sequence flow for SMBus slave receiver N bytes + PEC ..... | 4256 |
| Figure 890. Bus transfer diagrams for SMBus slave receiver (SBC = 1) ..... | 4257 |
| Figure 891. Bus transfer diagrams for SMBus master transmitter ..... | 4258 |
| Figure 892. Bus transfer diagrams for SMBus master receiver ..... | 4260 |
| Figure 893. I3C block diagram ..... | 4289 |
| Figure 894. I3C (primary) controller state and programming sequence diagram ..... | 4293 |
| Figure 895. I3C target state and programing sequence diagram ..... | 4298 |
| Figure 896. I3C CCC messages, as controller ..... | 4312 |
| Figure 897. I3C broadcast ENTDAACCC, as controller ..... | 4313 |
| Figure 898. I3C broadcast, direct read and direct write RSTACT CCC, as controller ..... | 4314 |
| Figure 899. I3C CCC messages, as target ..... | 4316 |
| Figure 900. I3C broadcast ENTDAACCC, as target ..... | 4317 |
| Figure 901. I3C broadcast DEFTGTS CCC, as target ..... | 4318 |
| Figure 902. I3C broadcast DEFGRPA CCC, as target ..... | 4319 |
| Figure 903. I3C private read/write messages, as controller ..... | 4321 |
| Figure 904. I3C private read/write messages, as target ..... | 4322 |
| Figure 905. Legacy I2C read/write messages, as controller ..... | 4323 |
| Figure 906. IBI transfer, as controller/target | 4324 |
| Figure 907. Hot-join request transfer, as controller/target | 4325 |
| Figure 908. Controller-role request transfer, as controller/target | 4326 |
| Figure 909. C-FIFO management, as controller | 4327 |
| Figure 910. TX-FIFO management, as controller | 4329 |
| Figure 911. RX-FIFO management, as controller | 4331 |
| Figure 912. S-FIFO management, as controller | 4334 |
| Figure 913. RX-FIFO management, as target | 4335 |
| Figure 914. TX-FIFO management with I3C_TGTTDR, as target | 4337 |
| Figure 915. TX-FIFO management by software without I3C_TGTTDR if reading less bytes than TX-FIFO size, as target | 4339 |
| Figure 916. USART block diagram | 4399 |
| Figure 917. Word length programming | 4403 |
| Figure 918. Configurable stop bits | 4405 |
| Figure 919. TC/TXE behavior when transmitting | 4407 |
| Figure 920. Start bit detection when oversampling by 16 or 8 | 4408 |
| Figure 921. usart_ker_ck clock divider block diagram | 4411 |
| Figure 922. Data sampling when oversampling by 16 | 4412 |
| Figure 923. Data sampling when oversampling by 8 | 4413 |
| Figure 924. Mute mode using Idle line detection | 4420 |
| Figure 925. Mute mode using address mark detection | 4421 |
| Figure 926. Break detection in LIN mode (11-bit break length - LBDL bit is set) | 4424 |
| Figure 927. Break detection in LIN mode vs. Framing error detection | 4425 |
| Figure 928. USART example of synchronous master transmission | 4426 |
| Figure 929. USART data clock timing diagram in synchronous master mode (M bits = 00) | 4426 |
| Figure 930. USART data clock timing diagram in synchronous master mode (M bits = 01) | 4427 |
| Figure 931. USART data clock timing diagram in synchronous slave mode (M bits = 00) | 4428 |
| Figure 932. ISO 7816-3 asynchronous protocol | 4430 |
| Figure 933. Parity error detection using the 1.5 stop bits | 4432 |
| Figure 934. IrDA SIR ENDEC block diagram | 4436 |
| Figure 935. IrDA data modulation (3/16) - normal mode | 4436 |
| Figure 936. Transmission using DMA | 4438 |
| Figure 937. Reception using DMA | 4439 |
| Figure 938. Hardware flow control between two USARTs | 4439 |
| Figure 939. RS232 RTS flow control | 4440 |
| Figure 940. RS232 CTS flow control | 4441 |
| Figure 941. LPUART block diagram | 4491 |
| Figure 942. LPUART word length programming | 4495 |
| Figure 943. Configurable stop bits | 4497 |
| Figure 944. TC/TXE behavior when transmitting | 4499 |
| Figure 945. lpuart_ker_ck clock divider block diagram | 4503 |
| Figure 946. Mute mode using Idle line detection | 4507 |
| Figure 947. Mute mode using address mark detection | 4508 |
| Figure 948. Transmission using DMA | 4510 |
| Figure 949. Reception using DMA | 4511 |
| Figure 950. Hardware flow control between two LPUARTs | 4512 |
| Figure 951. RS232 RTS flow control | 4512 |
| Figure 952. RS232 CTS flow control | 4513 |
| Figure 953. SPI/I2S block diagram | 4550 |
| Figure 954. Full-duplex single master/ single slave application . . . . . | 4554 |
| Figure 955. Half-duplex single master/ single slave application . . . . . | 4554 |
| Figure 956. Simplex single master / single slave application (master in transmit-only / slave in receive-only mode) . . . . . | 4555 |
| Figure 957. Master and three independent slaves connected in star topology . . . . . | 4556 |
| Figure 958. Master and three slaves connected in circular (daisy chain) topology . . . . . | 4558 |
| Figure 959. Multimaster application . . . . . | 4559 |
| Figure 960. Scheme of SS control logic. . . . . | 4561 |
| Figure 961. Data flow timing control (SSOE = 1, SSOM = 0, SSM = 0) . . . . . | 4561 |
| Figure 962. SS interleaving pulses between data (SSOE = 1, SSOM = 1, SSM = 0) . . . . . | 4562 |
| Figure 963. Data clock timing diagram . . . . . | 4564 |
| Figure 964. Data alignment when data size is not equal to 8, 16 or 32 bits . . . . . | 4565 |
| Figure 965. Packing data in FIFO for transmission and reception for a full-featured instance . . . . . | 4574 |
| Figure 966. TI mode transfer . . . . . | 4577 |
| Figure 967. Optional configurations of the slave behavior when an underrun condition is detected . . . . . | 4579 |
| Figure 968. Waveform examples . . . . . | 4587 |
| Figure 969. Master I2S Philips protocol waveforms (16/32-bit full accuracy) . . . . . | 4588 |
| Figure 970. I2S Philips standard waveforms . . . . . | 4588 |
| Figure 971. Master MSB-justified 16- or 32-bit full-accuracy length . . . . . | 4589 |
| Figure 972. Master MSB-justified 16- or 24-bit data length . . . . . | 4589 |
| Figure 973. Slave MSB-justified 16-, 24- or 32-bit data length . . . . . | 4590 |
| Figure 974. LSB-justified 16 or 24-bit data length . . . . . | 4590 |
| Figure 975. Master PCM when the frame length is equal the data length . . . . . | 4591 |
| Figure 976. Master PCM standard waveforms (16 or 24-bit data length) . . . . . | 4591 |
| Figure 977. Slave PCM waveforms . . . . . | 4592 |
| Figure 978. Startup sequence, I2S Philips standard, master. . . . . | 4595 |
| Figure 979. Startup sequence, I2S Philips standard, slave . . . . . | 4596 |
| Figure 980. Stop sequence, I2S Philips standard, master. . . . . | 4596 |
| Figure 981. I2S clock generator architecture . . . . . | 4597 |
| Figure 982. Data Format . . . . . | 4599 |
| Figure 983. Handling of underrun situation . . . . . | 4601 |
| Figure 984. Handling of overrun situation . . . . . | 4602 |
| Figure 985. Frame error detection, with FIXCH = 0 . . . . . | 4603 |
| Figure 986. Frame error detection, with FIXCH = 1 . . . . . | 4603 |
| Figure 987. SAI functional block diagram . . . . . | 4633 |
| Figure 988. Audio frame . . . . . | 4637 |
| Figure 989. FS role is start of frame + channel side identification (FSDEF = TRIS = 1) . . . . . | 4639 |
| Figure 990. FS role is start of frame (FSDEF = 0) . . . . . | 4640 |
| Figure 991. Slot size configuration with FBOFF = 0 in SAI_xSLOTR . . . . . | 4641 |
| Figure 992. First bit offset . . . . . | 4641 |
| Figure 993. Audio block clock generator overview . . . . . | 4643 |
| Figure 994. PDM typical connection and timing. . . . . | 4647 |
| Figure 995. Detailed PDM interface block diagram . . . . . | 4648 |
| Figure 996. Start-up sequence . . . . . | 4649 |
| Figure 997. SAI_ADR format in TDM, 32-bit slot width . . . . . | 4650 |
| Figure 998. SAI_ADR format in TDM, 16-bit slot width . . . . . | 4651 |
| Figure 999. SAI_ADR format in TDM, 8-bit slot width . . . . . | 4652 |
| Figure 1000. AC'97 audio frame . . . . . | 4655 |
| Figure 1001. Example of typical AC'97 configuration on devices featuring at least two embedded SAIs (three external AC'97 decoders) . . . . . | 4656 |
| Figure 1002. SPDIF format . . . . . | 4657 |
| Figure 1003. SAI_xDR register ordering . . . . . | 4658 |
| Figure 1004. Data companding hardware in an audio block in the SAI . . . . . | 4661 |
| Figure 1005. Tristate strategy on SD output line on an inactive slot . . . . . | 4663 |
| Figure 1006. Tristate on output data line in a protocol like I2S . . . . . | 4664 |
| Figure 1007. Overrun detection error. . . . . | 4665 |
| Figure 1008. FIFO underrun event . . . . . | 4665 |
| Figure 1009. SPDIFRX block diagram . . . . . | 4702 |
| Figure 1010. S/PDIF sub-frame format . . . . . | 4703 |
| Figure 1011. S/PDIF block format . . . . . | 4704 |
| Figure 1012. S/PDIF Preambles . . . . . | 4704 |
| Figure 1013. Channel coding example . . . . . | 4705 |
| Figure 1014. SPDIFRX decoder . . . . . | 4706 |
| Figure 1015. Noise filtering and edge detection . . . . . | 4706 |
| Figure 1016. Thresholds . . . . . | 4708 |
| Figure 1017. Synchronization flowchart. . . . . | 4710 |
| Figure 1018. Synchronization process scheduling . . . . . | 4711 |
| Figure 1019. SPDIFRX States . . . . . | 4712 |
| Figure 1020. SPDIFRX_FMTx_DR register format . . . . . | 4714 |
| Figure 1021. Channel/user data format . . . . . | 4715 |
| Figure 1022. S/PDIF overrun error when RXSTEO = 0 . . . . . | 4717 |
| Figure 1023. S/PDIF overrun error when RXSTEO = 1 . . . . . | 4718 |
| Figure 1024. SPDIFRX interface interrupt mapping diagram . . . . . | 4721 |
| Figure 1025. CAN subsystem . . . . . | 4739 |
| Figure 1026. FDCAN block diagram . . . . . | 4741 |
| Figure 1027. Transceiver delay measurement . . . . . | 4746 |
| Figure 1028. Pin control in bus monitoring mode . . . . . | 4748 |
| Figure 1029. Pin control in loop back mode. . . . . | 4750 |
| Figure 1030. CAN error state diagram. . . . . | 4751 |
| Figure 1031. Message RAM configuration. . . . . | 4752 |
| Figure 1032. Standard message ID filter path . . . . . | 4755 |
| Figure 1033. Extended message ID filter path. . . . . | 4756 |
| Figure 1034. Example of mixed configuration dedicated Tx buffers / Tx FIFO . . . . . | 4762 |
| Figure 1035. Example of mixed configuration dedicated Tx buffers / Tx queue . . . . . | 4762 |
| Figure 1036. Bit timing . . . . . | 4764 |
| Figure 1037. Bypass operation . . . . . | 4766 |
| Figure 1038. FSM calibration. . . . . | 4767 |
| Figure 1039. Cycle time and global time synchronization . . . . . | 4782 |
| Figure 1040. TTCAN level 0 and level 2 drift compensation . . . . . | 4783 |
| Figure 1041. Level 0 schedule synchronization state machine . . . . . | 4790 |
| Figure 1042. Level 0 master to slave relation . . . . . | 4791 |
| Figure 1043. USB subsystem overview . . . . . | 4868 |
| Figure 1044. USB2 host high-speed port block diagram . . . . . | 4870 |
| Figure 1045. USB2 host high-speed port reset . . . . . | 4872 |
| Figure 1046. USB3 DRD port block diagram . . . . . | 4878 |
| Figure 1047. USB3 DRD port reset . . . . . | 4880 |
| Figure 1048. VBUS connection diagram . . . . . | 4885 |
| Figure 1049. USB Type-C implementation . . . . . | 4890 |
| Figure 1050. USB Type-C and power delivery block diagram . . . . . | 4891 |
| Figure 1051. USB Type-C and power delivery reset . . . . . | 4892 |
| Figure 1052. USB3DR block diagram . . . . . | 4895 |
| Figure 1053. USBH block diagram . . . . . | 4998 |
| Figure 1054. UCPD block diagram . . . . . | 5014 |
| Figure 1055. Clock division and timing elements. . . . . | 5015 |
| Figure 1056.K-code transmission . . . . . | 5017 |
| Figure 1057.Transmit order for various sizes of data . . . . . | 5019 |
| Figure 1058.Packet format . . . . . | 5019 |
| Figure 1059.Line format of Hard Reset. . . . . | 5020 |
| Figure 1060.Line format of Cable Reset. . . . . | 5020 |
| Figure 1061.BIST test data frame. . . . . | 5021 |
| Figure 1062.BIST Carrier Mode 2 frame. . . . . | 5022 |
| Figure 1063.UCPD BMC transmitter architecture. . . . . | 5022 |
| Figure 1064.UCPD BMC receiver architecture . . . . . | 5024 |
| Figure 1065.PCIE subsystem diagram . . . . . | 5052 |
| Figure 1066.PCIE controller block diagram . . . . . | 5056 |
| Figure 1067.COMBOPHY block diagram . . . . . | 5059 |
| Figure 1068.Ethernet subsystem block diagram. . . . . | 5062 |
| Figure 1069.ETHSS external signals (simplified view) . . . . . | 5063 |
| Figure 1070.Ethernet subsystem internal signals . . . . . | 5064 |
| Figure 1071.Ethernet high-level block diagram . . . . . | 5075 |
| Figure 1072.DMA transmission flow (standard mode) . . . . . | 5078 |
| Figure 1073.DMA transmission flow (OSP mode) . . . . . | 5080 |
| Figure 1074.Receive DMA flow . . . . . | 5082 |
| Figure 1075.Overview of MAC transmission flow . . . . . | 5085 |
| Figure 1076.MAC reception flow . . . . . | 5087 |
| Figure 1077.Packet filtering sequence . . . . . | 5104 |
| Figure 1078.Networked time synchronization . . . . . | 5118 |
| Figure 1079.Propagation delay calculation in clocks supporting peer-to-peer path correction . . . . . | 5119 |
| Figure 1080.System time update using fine correction method . . . . . | 5129 |
| Figure 1081.Time aware shaper implementation for traffic scheduling. . . . . | 5141 |
| Figure 1082.Implementing a guard band to avoid delays due to interfering frames . . . . . | 5142 |
| Figure 1083.GCL governing gate close and open events block diagram (from IEEE 802.1 Qbv specifications) . . . . . | 5143 |
| Figure 1084.GCL and associated registers - BaseTime and CycleTime . . . . . | 5147 |
| Figure 1085.GCL and associated registers - BaseTime and CycleTime list execution time > CycleTime . . . . . | 5148 |
| Figure 1086.Switching to a new Configuration that is Aligned with the Existing Configuration. . . . . | 5149 |
| Figure 1087.Switching to the New List by Truncating the Current List . . . . . | 5151 |
| Figure 1088.Switching to New List By Extending the Current List . . . . . | 5152 |
| Figure 1089.mPacket formats. . . . . | 5156 |
| Figure 1090.MAC data Alignment Feature . . . . . | 5161 |
| Figure 1091.Time-based scheduler implementation. . . . . | 5169 |
| Figure 1092.Time-based scheduling flow . . . . . | 5170 |
| Figure 1093.TCP segmentation offload overview. . . . . | 5176 |
| Figure 1094.TCP segmentation offload flow. . . . . | 5177 |
| Figure 1095.Header and payload fields of segmented packets . . . . . | 5180 |
| Figure 1096.Supported PHY interfaces . . . . . | 5192 |
| Figure 1097.SMA Interface block . . . . . | 5193 |
| Figure 1098.MDIO packet structure (Clause 45) . . . . . | 5194 |
| Figure 1099.MDIO packet structure (Clause 22) . . . . . | 5195 |
| Figure 1100.SMA write operation flow . . . . . | 5196 |
| Figure 1101.Write data packet . . . . . | 5197 |
| Figure 1102.Read data packet . . . . . | 5197 |
| Figure 1103.Media independent interface (MII) signals . . . . . | 5199 |
| Figure 1104.RMII block diagram. . . . . | 5201 |
| Figure 1105. Transmission bit order . . . . . | 5202 |
| Figure 1106. Receive bit order. . . . . | 5203 |
| Figure 1107. RGMII block diagram and interface signals . . . . . | 5204 |
| Figure 1108. LPI transitions (Transmit, 100 Mbds) . . . . . | 5213 |
| Figure 1109. LPI Tx clock gating (when LPITCSE = 1) . . . . . | 5214 |
| Figure 1110. LPI transitions (receive, 100 Mbps) . . . . . | 5215 |
| Figure 1111. Descriptor ring structure . . . . . | 5247 |
| Figure 1112. DMA descriptor ring . . . . . | 5248 |
| Figure 1113. Descriptor tail pointer example 1 . . . . . | 5249 |
| Figure 1114. Descriptor tail pointer example 2 . . . . . | 5249 |
| Figure 1115. Transmit descriptor (read format) . . . . . | 5250 |
| Figure 1116. Transmit descriptor write-back format. . . . . | 5255 |
| Figure 1117. Transmit context descriptor format . . . . . | 5260 |
| Figure 1118. Receive normal descriptor (read format) . . . . . | 5263 |
| Figure 1119. Receive normal descriptor (write-back format). . . . . | 5266 |
| Figure 1120. Receive context descriptor . . . . . | 5274 |
| Figure 1121. Enhanced normal descriptor (read format). . . . . | 5276 |
| Figure 1122. Enhanced normal descriptor (write format). . . . . | 5277 |
| Figure 1123. Enhanced context descriptor (read format) . . . . . | 5278 |
| Figure 1124. Enhanced context descriptor (write format) . . . . . | 5279 |
| Figure 1125. Generation of ETH_DMAISR flags . . . . . | 5301 |
| Figure 1126. Block diagram . . . . . | 5518 |
| Figure 1127. FES overview . . . . . | 5522 |
| Figure 1128. Ethernet frame formats . . . . . | 5523 |
| Figure 1129. Redundancy tagged frame . . . . . | 5527 |
| Figure 1130. Token bucket . . . . . | 5528 |
| Figure 1131. Ethernet frame with preemption . . . . . | 5529 |
| Figure 1132. FES block diagram . . . . . | 5530 |
| Figure 1133. FES forwarding path (GMII/MII port). . . . . | 5531 |
| Figure 1134. Ethernet frame timestamp point . . . . . | 5533 |
| Figure 1135. Forwarding decision . . . . . | 5536 |
| Figure 1136. IPO . . . . . | 5538 |
| Figure 1137. Frame priority . . . . . | 5539 |
| Figure 1138. Decoding Drop Eligibility of RX frame. . . . . | 5540 |
| Figure 1139. Encoding Drop Eligibility for TX frame . . . . . | 5541 |
| Figure 1140. Metering principle . . . . . | 5542 |
| Figure 1141. Policing . . . . . | 5543 |
| Figure 1142. Mapping frames to policers. . . . . | 5545 |
| Figure 1143. Ethernet frame with Time Trailer . . . . . | 5547 |
| Figure 1144. Ethernet frame with 8-bit Management Trailer . . . . . | 5548 |
| Figure 1145. Ethernet frame with 16-bit Management Trailer . . . . . | 5548 |
| Figure 1146. 16-bit Management Trailer with 8-bit offset . . . . . | 5549 |
| Figure 1147. Static MAC Address table. . . . . | 5551 |
| Figure 1148. Calculation of Hash functions for Static MAC Address table . . . . . | 5552 |
| Figure 1149. MAC Address search and Forwarding decision . . . . . | 5554 |
| Figure 1150. Frame Early Drop algorithm . . . . . | 5559 |
| Figure 1151. Stream number . . . . . | 5562 |
| Figure 1152. Pointers from SMAC table . . . . . | 5563 |
| Figure 1153. Effect of FRER on the Forwarding Decision. . . . . | 5564 |
| Figure 1154. FRTC interfaces . . . . . | 5567 |
| Figure 1155. FSC, Schedulers and tables . . . . . | 5568 |
| Figure 1156. Downcounter, emergency disable and scheduler. . . . . | 5569 |
| Figure 1157.Starttime . . . . . | 5570 |
| Figure 1158.FPTS interfaces . . . . . | 5571 |
| Figure 1159.Internal block(s) . . . . . | 5572 |
| Figure 1160.Base address pointers . . . . . | 5573 |
| Figure 1161.Internal blocks. . . . . | 5574 |
| Figure 1162.AHB2Avalon interfaces. . . . . | 5575 |
| Figure 1163.RGMII adapter block diagram. . . . . | 5578 |
| Figure 1164.System block diagram . . . . . | 5734 |
| Figure 1165.Topology example . . . . . | 5736 |
| Figure 1166.ACM block diagram . . . . . | 5737 |
| Figure 1167.Frame format according to IEEE 802.1Q . . . . . | 5738 |
| Figure 1168.Bypass module block diagram . . . . . | 5741 |
| Figure 1169.Schedule execution example . . . . . | 5743 |
| Figure 1170.Redundant schedule execution example . . . . . | 5744 |
| Figure 1171.Hardware debug port block diagram. . . . . | 5746 |
| Figure 1172.SERF overview . . . . . | 5754 |
| Figure 1173.AXI SERD block diagram . . . . . | 5756 |
| Figure 1174.AHB SERD for IP block diagram . . . . . | 5757 |
| Figure 1175.AHB SERD for ICN block diagram . . . . . | 5758 |
| Figure 1176.AHB SERDAB for AHB2APB block diagram . . . . . | 5759 |
| Figure 1177.SERC block diagram . . . . . | 5759 |
| Figure 1178.SERF with an RISUP . . . . . | 5760 |
| Figure 1179.Block diagram of debug support infrastructure. . . . . | 5776 |
| Figure 1180.Debug clock domains . . . . . | 5778 |
| Figure 1181.Debug and access port connections. . . . . | 5783 |
| Figure 1182.Debug APB CoreSight topology . . . . . | 5787 |
| Figure 1183.CoreSight timestamp distribution . . . . . | 5789 |
| Figure 1184.Embedded cross trigger . . . . . | 5790 |
| Figure 1185.Mapping trigger inputs to outputs . . . . . | 5795 |
| Figure 1186.Cross trigger configuration example . . . . . | 5796 |
| Figure 1187.System trace macrocell . . . . . | 5800 |
| Figure 1188.Cortex-M33 CoreSight topology . . . . . | 5831 |
| Figure 1189.Cortex-M0+ CoreSight topology . . . . . | 5835 |