98. Device electronic signature
The device electronic signature are either set in hardware or stored in the OTP (visible in BSEC registers) which can be read using the debug interface or by the CPU. It contains factory-programmed identification data that allow the user firmware or other external devices to automatically match the characteristics of the component.
98.1 Unique device ID register (96 bits) (UID)
The unique device identifier is ideally suited to be used:
- • as serial number (USB string serial number, or other end applications)
- • as part of the security keys, to increase the security of code in flash memory while using and combining this unique ID with software cryptographic primitives and protocols before programming the memory
- • during processes such as secure boot
The 96-bit unique device identifier provides a reference number, unique for a given device and in any context. These bits cannot be altered by the user.
Base address: 0x4400 0000 (BSEC base address on APB3)
Address offset: 0x014 (BSEC_FVR5)
Read-only = 0xXXXX XXXX where X is factory-programmed
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| UID[31:16] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| UID[15:0] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
Bits 31:0 UID[31:0]: 31:0 unique ID bits
Address offset: 0x018 (BSEC_FVR6)
Read-only = 0xXXXX XXXX where X is factory-programmed
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| UID[63:48] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| UID[47:32] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
Bits 31:0 UID[63:32]: 63:32 unique ID bits
Address offset: 0x01C (BSEC_FVR7)
Read-only = 0XXXXX XXXX where X is factory-programmed
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| UID[95:80] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| UID[79:64] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
Bits 31:0 UID[95:64]: 95:64 unique ID bits
98.2 Device part number (RPN)
Base address: 0x4400 0000 (BSEC base address on APB3)
Address offset: 0x024 (BSEC_FVR9)
Read-only = 0XXXXX XXXX where X is factory-programmed
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| RPN_CODING[31:16] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RPN_CODING[15:0] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |

Bits 31:0 RPN_CODING[31:0]:
| 0x00002000: | STM32MP257Cxx |
| 0x00082000: | STM32MP255Cxx |
| 0x00082182: | STM32MP235Cxx |
| 0x000B300C: | STM32MP253Cxx |
| 0x000B306D: | STM32MP251Cxx |
| 0x000B318E: | STM32MP233Cxx |
| 0x000B31EF: | STM32MP231Cxx |
| 0x40002E00: | STM32MP257Axx |
| 0x40082E00: | STM32MP255Axx |
| 0x40082F82: | STM32MP235Axx |
| 0x400B3E0C: | STM32MP253Axx |
| 0x400B3E6D: | STM32MP251Axx |
| 0x400B3F8E: | STM32MP233Axx |
| 0x400B3FEF: | STM32MP231Axx |
| 0x80002000: | STM32MP257Fxx |
| 0x80082000: | STM32MP255Fxx |
| 0x80082182: | STM32MP235Fxx |
| 0x800B300C: | STM32MP253Fxx |
| 0x800B306D: | STM32MP251Fxx |
| 0x800B318E: | STM32MP233Fxx |
| 0x800B31EF: | STM32MP231Fxx |
| 0xC0002E00: | STM32MP257Dxx |
| 0xC0082E00: | STM32MP255Dxx |
| 0xC0082F82: | STM32MP235Dxx |
| 0xC00B3E0C: | STM32MP253Dxx |
| 0xC00B3E6D: | STM32MP251Dxx |
| 0xC00B3F8E: | STM32MP233Dxx |
| 0xC00B3FEF: | STM32MP231Dxx |
| Others: Reserved | |
98.3 Device version
Base address: 0x4400 0000 (BSEC base address on APB3)
Address offset: 0x198 (BSEC_FVR102)
Read-only = 0xXXXX XXXX where X is factory-programmed
Note: BSEC_FVR102 register is not automatically shadowed with OTP content, so a fuse read sequence must be issued to get the register updated once (clear after reading). Refer to BSEC section "Operations on fuses".
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| OPTIONS[25:10] | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| OPTIONS[9:0] | REV_ID[5:0] | ||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | r | r | r | r | r |

Bits 31:6 OPTIONS[25:0]:
0: No options
Bits 5:0 REV_ID[5:0]: Silicon revision
98.4 Package data register (PKG)
Base address: 0x4400 0000 (BSEC base address on APB3)
Address offset: 0x1E8 (BSEC_FVR122)
Read-only = 0XXXXX XXXX where X is factory-programmed
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| r | r | r | |||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | PKG[2:0] | ||
| r | r | r | |||||||||||||
Bits 31:3 Reserved, must be kept at reset value.
Bits 2:0 PKG[2:0]: Package type
000: Custom packages
001: VFBGA361 (10 ×10 mm)
011: VFBGA424 (14 ×14 mm)
101: TFBGA436 (18 × 18 mm)
111: TFBGA361 (16 × 16 mm)
Others: Reserved