43. Advanced-control timers (TIM1/TIM8)

43.1 TIM1/TIM8 introduction

The advanced-control timers (TIM1/TIM8) consist of a 16-bit autoreload counter driven by a programmable prescaler.

It may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM, complementary PWM with dead-time insertion).

Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler and the RCC clock controller prescalers.

The advanced-control (TIM1/TIM8) and general-purpose (TIMy) timers are completely independent, and do not share any resources. They can be synchronized together as described in Section 43.3.30: Timer synchronization.

43.2 TIM1/TIM8 main features

TIM1/TIM8 timer features include:

43.3 TIM1/TIM8 functional description

43.3.1 Block diagram

Figure 404. Advanced-control timer block diagram

Figure 404. Advanced-control timer block diagram showing connections between APB bus, IRQ and DMA interfaces, trigger/slave controllers, encoder interface, prescaler, auto-reload register, repetition counter, capture/compare registers 1 to 6, DTG registers, output controls, break and break2 circuitry, and external signals.

Notes:

MSv45751V6

Figure 404. Advanced-control timer block diagram showing connections between APB bus, IRQ and DMA interfaces, trigger/slave controllers, encoder interface, prescaler, auto-reload register, repetition counter, capture/compare registers 1 to 6, DTG registers, output controls, break and break2 circuitry, and external signals.
  1. 1. This feature is not available on all timers, refer to Section 43.3.2: TIM1/TIM8 pins and internal signals.
  2. 2. See Figure 451: Break and Break2 circuitry overview for details.

43.3.2 TIM1/TIM8 pins and internal signals

The tables in this section summarize the TIM inputs and outputs

Table 450. TIM input/output pins

Pin nameSignal typeDescription
TIM_CH1
TIM_CH2
TIM_CH3
TIM_CH4
Input/outputTimer multi-purpose channels.
Each channel can be used for capture, compare or PWM.
TIM_CH1 and TIM_CH2 can also be used as external clock (below 1/4 of the tim_ker_ck clock), external trigger and quadrature encoder inputs.
TIM_CH1, TIM_CH2 and TIM_CH3 can be used to interface with digital hall effect sensors.
TIM_CH1N
TIM_CH2N
TIM_CH3N
TIM_CH4N
OutputTimer complementary outputs, derived from TIM_CHx outputs with the possibility to have deadtime insertion.
TIM_ETRInputExternal trigger input. This input can be used as external trigger or as external clock source. This input can receive a clock with a frequency higher than the tim_ker_ck if the tim_etr_in prescaler is used.
TIM_BKIN
TIM_BKIN2
Input/outputBreak and Break2 inputs. These inputs can also be configured in bidirectional mode.

Table 451. TIM internal input/output signals

Internal signal nameSignal typeDescription
tim_ti1_in[15:0]
tim_ti2_in[15:0]
tim_ti3_in[15:0]
tim_ti4_in[15:0]
InputInternal timer inputs bus. The tim_ti1_in[15:0] and tim_ti2_in[15:0] inputs can be used for capture or as external clock (below 1/4 of the tim_ker_ck clock) and for quadrature encoder signals.
tim_etr[15:0]InputExternal trigger internal input bus. These inputs can be used as trigger, external clock or for hardware cycle-by-cycle pulsewidth control. These inputs can receive clock with a frequency higher than the tim_ker_ck if the tim_etr_in prescaler is used.
tim_itr[15:0]InputInternal trigger input bus. These inputs can be used for the slave mode controller or as a input clock (below 1/4 of the tim_ker_ck clock).
tim_trgo/tim_trgo2OutputInternal trigger outputs. These triggers are used by other timers and /or other peripherals.

Table 451. TIM internal input/output signals (continued)

Internal signal nameSignal typeDescription
tim_ocref_clr[7:0]InputTimer tim_ocref_clr input bus. These inputs can be used to clear the tim ocxref signals, typically for hardware cycle-by-cycle pulsewidth control.
tim_brk_cmp[8:1]InputBreak input for internal signals
tim_brk2_cmp[8:1]InputBreak2 input for internal signals
tim_sys_brk[n:0]InputSystem break input. This input gathers the MCU's system level errors.
tim_pclkInputTimer APB clock
tim_ker_ckInputTimer kernel clock
tim_cc_itOutputTimer capture/compare interrupt
tim_upd_itOutputTimer update event interrupt
tim_brk_terr_ierr_itOutputTimer break, break2, transition error and index error interrupt
tim_trgi_com_dir_idx_itOutputTimer trigger, commutation, direction and index interrupt
tim_cc1_dma
tim_cc2_dma
tim_cc3_dma
tim_cc4_dma
OutputTimer capture / compare 1..4 dma requests
tim_upd_dmaOutputTimer update dma request
tim_trgi_dmaOutputTimer trigger dma request
tim_com_dmaOutputTimer commutation dma request

Table 452, Table 453, Table 454 and Table 455 list the sources connected to the tim_ti[4:1] input multiplexers.

Table 452. Interconnect to the tim_ti1 input multiplexer

tim_ti1 inputsSources
TIM1TIM8
tim_ti1_in0TIM1_CH1TIM8_CH1
tim_ti1_in1ReservedReserved
tim_ti1_in2comp1_out(1)comp1_out(1)
tim_ti1_in3comp2_out(1)comp2_out(1)
tim_ti1_in[15:4]ReservedReserved

1. STM32H543/553xx devices only.

Table 453. Interconnect to the tim_ti2 input multiplexer

tim_ti2 inputsSources
TIM1TIM8
tim_ti2_in0TIM1_CH2TIM8_CH2
tim_ti2_in[15:1]ReservedReserved

Table 454. Interconnect to the tim_ti3 input multiplexer

tim_ti3 inputsSources
TIM1TIM8
tim_ti3_in0TIM1_CH3TIM8_CH3
tim_ti3_in[15:1]ReservedReserved

Table 455. Interconnect to the tim_ti4 input multiplexer

tim_ti4 inputsSources
TIM1TIM8
tim_ti4_in0TIM1_CH4TIM8_CH4
tim_ti4_in[15:1]ReservedReserved

Table 456 lists the internal sources connected to the tim_itr input multiplexer.

Table 456. Internal trigger connection

Timer internal trigger input signalTIM1TIM8
tim_itr0Reservedtim1_trgo
tim_itr1tim2_trgotim2_trgo

Table 456. Internal trigger connection (continued)

Timer internal trigger input signalTIM1TIM8
tim_itr2tim3_trgotim3_trgo
tim_itr3tim4_trgotim4_trgo
tim_itr4tim5_trgotim5_trgo
tim_itr5tim8_trgoReserved
tim_itr6tim12_trgotim12_trgo
tim_itr7tim13_oc1(1)tim13_oc1(1)
tim_itr8tim14_oc1(1)tim14_oc1(1)
tim_itr9tim15_trgotim15_trgo
tim_itr10tim16_oc1(1)tim16_oc1(1)
tim_itr11tim17_oc1(1)tim17_oc1(1)
tim_itr[15:12]ReservedReserved

1. STM32H562/563/573xx devices only.

Table 457 lists the internal sources connected to the tim_etr input multiplexer.

Table 457. Interconnect to the tim_etr input multiplexer

Timer external trigger input signalTimer external trigger signals assignment
TIM1TIM8
tim_etr0TIM1_ETRTIM8_ETR
tim_etr1comp1_out(1)comp1_out(1)
tim_etr2comp2_out(1)comp2_out(1)
tim_etr3adc1_awd1adc2_awd1
tim_etr4adc1_awd2adc2_awd2
tim_etr5adc1_awd3adc2_awd3
tim_etr6Reservedadc3_awd1(1)
tim_etr7Reservedadc3_awd2(1)
tim_etr8Reservedadc3_awd3(1)
tim_etr[15:9]ReservedReserved

1. STM32H543/553xx devices only.

Table 458, Table 459 and Table 460 list the sources connected to the tim_brk and tim_brk2inputs.

Table 458. Timer break interconnect
tim_brk inputsTIM1TIM8
TIM_BKINTIM1_BKIN pinTIM8_BKIN pin
tim_brk_cmp1comp1_out(1)comp1_out(1)
tim_brk_cmp2comp2_out(1)comp2_out(1)
tim_brk_cmp3play_out1(1)play_out1(1)
tim_brk_cmp[8:4]ReservedReserved

1. STM32H543/553xx devices only.

Table 459. Timer break2 interconnect
tim_brk2 inputsTIM1TIM8
TIM_BKIN2TIM1_BKIN2 pinTIM8_BKIN2 pin
tim_brk2_cmp1comp1_out(1)comp1_out(1)
tim_brk2_cmp2comp2_out(1)comp2_out(1)
tim_brk2_cmp3play_out2(1)play_out2(1)
tim_brk2_cmp[8:4]ReservedReserved

1. STM32H543/553xx devices only.

Table 460. System break interconnect
tim_sys_brk inputsTIM1/TIM8Enable bit in SBS_CFGR2 register
tim_sys_brk0Flash memory double ECC errorECCL
tim_sys_brk1Programmable Voltage Detector (PVD)PVDL
tim_sys_brk2SRAM double ECC errorSEL
tim_sys_brk3Cortex-M33 LOCKUPCLL
CSSClock Security SystemNone (always enabled)
Table 461 lists the internal sources connected to the tim_oref_clr input multiplexer. Table 461. Interconnect to the tim_oref_clr input multiplexer(1)
Timer OCREF clear signalTimer OCREF clear signal assignment
TIM1TIM8
tim_oref_clr0comp1_outcomp1_out
im_oref_clr1comp2_outcomp2_out
tim_oref_clr[7:2]ReservedReserved

1. STM32H543/553xx devices only.

43.3.3 Time-base unit

The main block of the programmable advanced-control timer is a 16-bit counter with its related autoreload register. The counter can count up, down or both up and down. The counter clock can be divided by a prescaler.

The counter, the autoreload register and the prescaler register can be written or read by software, even when the counter is running.

The time-base unit includes:

The autoreload register is preloaded. Writing to or reading from the autoreload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the autoreload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow (or underflow when downcounting) and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detailed for each configuration.

The counter is clocked by the prescaler output tim_cnt_ck, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).

Note: The counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.

Prescaler description

The prescaler divides the counter clock frequency by any factor from 1 to 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 405 and Figure 406 give some examples of the counter behavior when the prescaler ratio is changed on the fly.

Figure 405. Counter timing diagram with prescaler division change from 1 to 2 Figure 405. Counter timing diagram with prescaler division change from 1 to 2. Shows clock signals tim_psc_ck, CEN, tim_cnt_ck, Counter register (counting F7, F8, F9, FA, FB, FC, 00, 01, 02, 03), Update event (UEV), Prescaler control register transitioning from 0 to 1 upon 'Write a new value in TIMx_PSC', Prescaler buffer updating from 0 to 1 at the UEV, and Prescaler counter counting 0, then alternating 0, 1, 0, 1, 0, 1.

MSv50998V1

Figure 405. Counter timing diagram with prescaler division change from 1 to 2. Shows clock signals tim_psc_ck, CEN, tim_cnt_ck, Counter register (counting F7, F8, F9, FA, FB, FC, 00, 01, 02, 03), Update event (UEV), Prescaler control register transitioning from 0 to 1 upon 'Write a new value in TIMx_PSC', Prescaler buffer updating from 0 to 1 at the UEV, and Prescaler counter counting 0, then alternating 0, 1, 0, 1, 0, 1.
Figure 406. Counter timing diagram with prescaler division change from 1 to 4 Figure 406. Counter timing diagram with prescaler division change from 1 to 4. Shows clock signals tim_psc_ck, CEN, tim_cnt_ck, Counter register (counting F7, F8, F9, FA, FB, FC, 00, 01), Update event (UEV), Prescaler control register transitioning from 0 to 3 upon 'Write a new value in TIMx_PSC', Prescaler buffer updating from 0 to 3 at UEV, and Prescaler counter counting 0, then 0, 1, 2, 3, 0, 1, 2, 3.

MSv50999V1

Figure 406. Counter timing diagram with prescaler division change from 1 to 4. Shows clock signals tim_psc_ck, CEN, tim_cnt_ck, Counter register (counting F7, F8, F9, FA, FB, FC, 00, 01), Update event (UEV), Prescaler control register transitioning from 0 to 3 upon 'Write a new value in TIMx_PSC', Prescaler buffer updating from 0 to 3 at UEV, and Prescaler counter counting 0, then 0, 1, 2, 3, 0, 1, 2, 3.

43.3.4 Counter modes

Upcounting mode

In upcounting mode, the counter counts from 0 to the autoreload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

If the repetition counter is used, the update event (UEV) is generated after upcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR) + 1. Else the update event is generated at each counter overflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.

Figure 407. Counter timing diagram, internal clock divided by 1

Timing diagram for counter with internal clock divided by 1. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (31-07), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The tim_psc_ck signal is a continuous clock. The CEN signal is an enable signal that starts at a low level and transitions to high. Upon the rising edge of CEN, the counter clock tim_cnt_ck begins, with its period equal to that of tim_psc_ck. The Counter register shows the count sequence: it starts at 31, increments to 32, 33, 34, 35, and 36, then wraps around to 00, 01, 02, 03, 04, 05, 06, and 07. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 36 to 00. This overflow triggers an Update event (UEV) pulse. The Update interrupt flag (UIF) is set to a high level on the rising edge of the UEV and remains high until cleared.

MSv50997V1

Timing diagram for counter with internal clock divided by 1. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (31-07), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 408. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0034-0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a continuous clock. The CEN signal starts low and transitions to high. The counter clock tim_cnt_ck has a period that is twice that of tim_psc_ck. The Counter register shows the count sequence: it starts at 0034, increments to 0035 and 0036, then wraps around to 0000, 0001, 0002, and 0003. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0036 to 0000. This overflow triggers an Update event (UEV) pulse. The Update interrupt flag (UIF) is set to a high level on the rising edge of the UEV and remains high until cleared.

MSv62300V1

Timing diagram for counter with internal clock divided by 2. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0034-0003), Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 409. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a high-frequency clock. The CEN (Counter Enable) signal is active low; when it transitions from high to low, the counter starts. The tim_cnt_ck signal is the prescaled clock, which has a frequency four times lower than tim_psc_ck. The Counter register shows the count value increasing by 1 on each rising edge of tim_cnt_ck. The sequence of values shown is 0035, 0036, 0000, and 0001. The Counter overflow signal is a pulse that occurs when the counter reaches its maximum value and rolls over to 0000. The Update event (UEV) signal is a pulse that occurs on the rising edge of the counter overflow. The Update interrupt flag (UIF) signal is a pulse that occurs on the rising edge of the update event. The diagram is labeled MSv62301V1 in the bottom right corner.

Timing diagram for counter with internal clock divided by 4. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 410. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. It shows the relationship between tim_psc_ck, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by an arbitrary factor N. The tim_psc_ck signal is a high-frequency clock. The tim_cnt_ck signal is the prescaled clock, which has a frequency N times lower than tim_psc_ck. The Counter register shows the count value increasing by 1 on each rising edge of tim_cnt_ck. The sequence of values shown is 1F, 20, and 00. The Counter overflow signal is a pulse that occurs when the counter reaches its maximum value and rolls over to 00. The Update event (UEV) signal is a pulse that occurs on the rising edge of the counter overflow. The Update interrupt flag (UIF) signal is a pulse that occurs on the rising edge of the update event. The diagram is labeled MSv62302V1 in the bottom right corner.

Timing diagram for counter with internal clock divided by N. It shows the relationship between tim_psc_ck, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 411. Counter timing diagram, update event when ARPE = 0
(TIMx_ARR not preloaded)

Timing diagram for counter update event when ARPE = 0 and TIMx_ARR is not preloaded. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

The diagram illustrates the timing of an update event in a timer when the auto-reload preload enable (ARPE) is 0 and the auto-reload register (TIMx_ARR) is not preloaded. The counter register is 32 bits wide, with bits 31-00 shown. The counter overflow occurs when the counter reaches 36 (0x24), which is the value in the auto-reload preload register. The update event (UEV) is generated on the rising edge of the counter overflow. The update interrupt flag (UIF) is set on the rising edge of the UEV. The counter register is then reloaded with the value from the auto-reload preload register (36). The diagram also shows the counter clock (tim_cnt_ck) and the prescaler clock (tim_psc_ck). The CEN signal is active low, indicating the counter is enabled. A write to the TIMx_ARR register is shown occurring before the counter overflow.

SignalValue / State
Counter register31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07
Auto-reload preload registerFF, 36

Write a new value in TIMx_ARR

MSv62303V1

Timing diagram for counter update event when ARPE = 0 and TIMx_ARR is not preloaded. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Figure 412. Counter timing diagram, update event when ARPE = 1
(TIMx_ARR preloaded)

Timing diagram for counter update event when ARPE = 1 (TIMx_ARR preloaded).

The diagram illustrates the timing of various signals during a counter update event when ARPE = 1 and TIMx_ARR is preloaded. The signals shown are:

A vertical dashed line indicates the point where a new value is written to TIMx_ARR. The diagram shows that the update event (UEV) is generated when the counter reaches 00, which is the value in the auto-reload preload register.

Timing diagram for counter update event when ARPE = 1 (TIMx_ARR preloaded).

Downcounting mode

In downcounting mode, the counter counts from the autoreload value (content of the TIMx_ARR register) down to 0, then restarts from the autoreload value and generates a counter underflow event.

If the repetition counter is used, the update event (UEV) is generated after downcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR) + 1. Else the update event is generated at each counter underflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV update event can be disabled by software by setting the UDIS bit in TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter restarts from the current autoreload value, whereas the counter of the prescaler restarts from 0 (but the prescale rate doesn't change).

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.

Figure 413. Counter timing diagram, internal clock divided by 1

Timing diagram for a counter with internal clock divided by 1. It shows the relationship between the prescaler clock (tim_psc_ck), the counter enable (CEN), the counter clock (tim_cnt_ck), the counter register values, the counter underflow (cnt_udf) flag, the update event (UEV), and the update interrupt flag (UIF). The counter register counts down from 05 to 00, then reloads to 36 and counts down to 2F. The counter underflow flag is set when the counter reaches 00. The update event (UEV) is set when the counter reaches 00. The update interrupt flag (UIF) is set when the update event occurs.

The diagram illustrates the timing of a counter with an internal clock divided by 1. The signals shown are:

MSv62305V1

Timing diagram for a counter with internal clock divided by 1. It shows the relationship between the prescaler clock (tim_psc_ck), the counter enable (CEN), the counter clock (tim_cnt_ck), the counter register values, the counter underflow (cnt_udf) flag, the update event (UEV), and the update interrupt flag (UIF). The counter register counts down from 05 to 00, then reloads to 36 and counts down to 2F. The counter underflow flag is set when the counter reaches 00. The update event (UEV) is set when the counter reaches 00. The update interrupt flag (UIF) is set when the update event occurs.

Figure 414. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0002 to 0033), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a high-frequency square wave. The CEN signal is an enable signal that starts low and transitions high. The tim_cnt_ck signal is the prescaled clock, which has a frequency half that of tim_psc_ck. The Counter register shows the sequence of values: 0002, 0001, 0000, 0036, 0035, 0034, and 0033. A Counter underflow occurs when the counter reaches 0000 and wraps around to 0036. The Update event (UEV) is generated on the rising edge of the counter underflow. The Update interrupt flag (UIF) is set on the rising edge of the update event.

MSv62306V1

Timing diagram for counter with internal clock divided by 2. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0002 to 0033), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 415. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0001 to 0001), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a high-frequency square wave. The CEN signal is an enable signal that starts low and transitions high. The tim_cnt_ck signal is the prescaled clock, which has a frequency one-fourth that of tim_psc_ck. The Counter register shows the sequence of values: 0001, 0000, 0000, and 0001. A Counter underflow occurs when the counter reaches 0000 and wraps around to 0001. The Update event (UEV) is generated on the rising edge of the counter underflow. The Update interrupt flag (UIF) is set on the rising edge of the update event.

MSv62307V1

Timing diagram for counter with internal clock divided by 4. Shows tim_psc_ck, CEN, tim_cnt_ck, Counter register (0001 to 0001), Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 416. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 416 showing tim_psc_ck, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by N. It shows two cycles of operation. In the first cycle, the counter register starts at 20 and counts up to 1F. In the second cycle, it starts at 00 and counts up to 36. The tim_psc_ck signal is the prescaled clock. The tim_cnt_ck signal is the counter clock, which is a divided version of the prescaled clock. The counter register updates on the falling edge of the counter clock. The counter underflow occurs when the counter reaches its maximum value and rolls over to zero. The update event (UEV) is generated on the falling edge of the counter clock following the underflow. The update interrupt flag (UIF) is set on the falling edge of the counter clock following the underflow.

Timing diagram for Figure 416 showing tim_psc_ck, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 417. Counter timing diagram, update event when repetition counter is not used

Timing diagram for Figure 417 showing tim_pasc_ck, CEN, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

This timing diagram illustrates the operation of a counter when the repetition counter is not used. It shows the relationship between the prescaled clock (tim_pasc_ck), the counter enable signal (CEN), the counter clock (tim_cnt_ck), the counter register, the counter underflow, the update event (UEV), the update interrupt flag (UIF), and the auto-reload preload register. The counter register starts at 05 and counts down to 00. When the counter reaches 00, it rolls over to 36 and continues counting down to 2F. The counter underflow occurs when the counter reaches 00. The update event (UEV) is generated on the falling edge of the counter clock following the underflow. The update interrupt flag (UIF) is set on the falling edge of the counter clock following the underflow. The auto-reload preload register is set to FF and is updated when a new value is written to the TIMx_ARR register.

Timing diagram for Figure 417 showing tim_pasc_ck, CEN, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Center-aligned mode (up/down counting)

In center-aligned mode, the counter counts from 0 to the autoreload value (content of the TIMx_ARR register) – 1, generates a counter overflow event, then counts from the

autoreload value down to 1 and generates a counter underflow event. Then it restarts counting from 0.

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are not equal to 00. The Output compare interrupt flag of channels configured in output is set when: the counter counts down (Center aligned mode 1, CMS = 01), the counter counts up (Center aligned mode 2, CMS = 10) the counter counts up and down (Center aligned mode 3, CMS = 11).

In this mode, the DIR direction bit in the TIMx_CR1 register cannot be written. It is updated by hardware and gives the current direction of the counter.

The update event can be generated at each counter overflow and at each counter underflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event. In this case, the counter restarts counting from 0, as well as the counter of the prescaler.

The UEV update event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter continues counting up and down, based on the current autoreload value.

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an UEV update event but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies.

Figure 418. Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6

Figure 418. Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6

MSv62310V1

Figure 418. Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6

Figure 419. Counter timing diagram, internal clock divided by 2

Figure 419. Counter timing diagram, internal clock divided by 2

MSv62311V1

Figure 419. Counter timing diagram, internal clock divided by 2

Figure 420. Counter timing diagram, internal clock divided by 4, TIMx_ARR = 0x36

Timing diagram for Figure 420 showing tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 0034, 0035, 0036, and 0035. A note at the bottom states: 'Note: Here, center_aligned mode 2 or 3 is updated with an UIF on overflow'.

Figure 420 is a timing diagram for a counter with an internal clock divided by 4. The diagram shows the following signals over time:

Note: Here, center_aligned mode 2 or 3 is updated with an UIF on overflow

MSv62312V1

Timing diagram for Figure 420 showing tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 0034, 0035, 0036, and 0035. A note at the bottom states: 'Note: Here, center_aligned mode 2 or 3 is updated with an UIF on overflow'.

Figure 421. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 421 showing tim_psc_ck, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 20, 1F, 01, and 00, indicating an underflow occurred after reaching 00.

Figure 421 is a timing diagram for a counter with an internal clock divided by N. The diagram shows the following signals over time:

MSv62313V1

Timing diagram for Figure 421 showing tim_psc_ck, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register values are 20, 1F, 01, and 00, indicating an underflow occurred after reaching 00.

Figure 422. Counter timing diagram, update event with ARPE = 1 (counter underflow)

Timing diagram for counter underflow with ARPE = 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. A write to TIMx_ARR is also indicated.

The diagram illustrates the timing of a counter underflow event when ARPE is set to 1. It shows the following signals and events over time:

A vertical dashed line indicates the point of the write to TIMx_ARR, which occurs during the counter value 05. The counter then continues its countdown from 00.

MSv62314V1

Timing diagram for counter underflow with ARPE = 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. A write to TIMx_ARR is also indicated.

Figure 423. Counter timing diagram, Update event with ARPE = 1 (counter overflow)

Timing diagram for counter overflow with ARPE = 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The Counter register shows values from F7 to 2F. The Counter overflow and UEV signals are active high pulses. The Auto-reload preload register shows a write to FD and then 36. The Auto-reload active register shows a write to FD and then 36. A note indicates 'Write a new value in TIMx_ARR'.

The diagram illustrates the timing of an update event (UEV) triggered by a counter overflow when ARPE = 1. The signals shown are:

A note indicates "Write a new value in TIMx_ARR" at the time of the update event.

Timing diagram for counter overflow with ARPE = 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload active register. The Counter register shows values from F7 to 2F. The Counter overflow and UEV signals are active high pulses. The Auto-reload preload register shows a write to FD and then 36. The Auto-reload active register shows a write to FD and then 36. A note indicates 'Write a new value in TIMx_ARR'.

MSv62315V1

43.3.5 Repetition counter

Section 43.3.3: Time-base unit describes how the update event (UEV) is generated with respect to the counter overflows/underflows. It is actually generated only when the repetition counter has reached zero. This can be useful when generating PWM signals.

This means that data are transferred from the preload registers to the shadow registers (TIMx_ARR autoreload register, TIMx_PSC prescaler register, but also TIMx_CCRx capture/compare registers in compare mode) every N+1 counter overflows or underflows, where N is the value in the TIMx_RCR repetition counter register.

The repetition counter is decremented:

The repetition counter is an autoreload type; the repetition rate is maintained as defined by the TIMx_RCR register value (refer to Figure 424). When the update event is generated by software (by setting the UG bit in TIMx_EGR register) or by hardware through the slave mode controller, it occurs immediately whatever the value of the repetition counter is and the repetition counter is reloaded with the content of the TIMx_RCR register.

In Center aligned mode, for odd values of RCR, the update event occurs either on the overflow or on the underflow depending on when the RCR register was written and when the counter was launched: if the RCR was written before launching the counter, the UEV occurs on the underflow. If the RCR was written after launching the counter, the UEV occurs on the overflow.

For example, for RCR = 3, the UEV is generated each 4th overflow or underflow event depending on when the RCR was written.

Figure 424. Update rate examples depending on mode and TIMx_RCR register settings

Figure 424 showing counter waveforms and update event (UEV) arrows for Counter-aligned mode, Edge-aligned mode (Upcounting and Downcounting) across different TIMx_RCR values (0, 1, 2, 3, and 3 with re-synchronization).

UEV → Update event: Preload registers transferred to active registers and update interrupt generated
Update Event if the repetition counter underflow occurs when the counter is equal to the auto-reload value

MSv31195V1

Figure 424 showing counter waveforms and update event (UEV) arrows for Counter-aligned mode, Edge-aligned mode (Upcounting and Downcounting) across different TIMx_RCR values (0, 1, 2, 3, and 3 with re-synchronization).

43.3.6 External trigger input

The timer features an external trigger input tim_etr_in. It can be used as:

Figure 425 below describes the tim_etr_in input conditioning. The input polarity is defined with the ETP bit in TIMxSMCR register. The trigger can be prescaled with the divider programmed by the ETPS[1:0] bitfield and digitally filtered with the ETF[3:0] bitfield. The resulting signal (tim_etrf) is available for three purposes: as an external clock, to condition

ST logo
ST logo

the output (typically to reset a PWM output for a current limitation), and as a trigger for the Slave mode controller.

Figure 425. External trigger input block

Block diagram of the External trigger input block. It shows the flow from TIMx_AF1[17:14] and TIM_ETR (tim_etr0) through a multiplexer to tim_etr_in. This is followed by a 2-to-1 multiplexer controlled by ETP (TIMx_SMCR), then a Divider (/1, /2, /4, /8) controlled by ETPS[1:0] (TIMx_SMCR), and finally a Filter downcounter controlled by ETF[3:0] (TIMx_SMCR). The output is tim_etr, which is also labeled f_DTS. The final output is tim_etr, which goes to the Output mode controller, CK_PSC circuitry, and Slave mode controller. A reference MSv62316V2 is at the bottom right.

The diagram illustrates the external trigger input block. It starts with two inputs: TIMx_AF1[17:14] and TIM_ETR (labeled tim_etr0). These inputs are combined and passed through a multiplexer to produce tim_etr_in. This signal then enters another multiplexer controlled by the ETP bit in the TIMx_SMCR register. The output of this multiplexer goes to a Divider block, which can divide by 1, 2, 4, or 8, controlled by the ETPS[1:0] bits in the TIMx_SMCR register. The divided signal, labeled tim_etrp, is then fed into a Filter downcounter block controlled by the ETF[3:0] bits in the TIMx_SMCR register. The final output is tim_etr, which is also labeled \(f_{DTS}\). This output is sent to the Output mode controller, the CK_PSC circuitry, and the Slave mode controller. A reference code MSv62316V2 is located in the bottom right corner of the diagram area.

Block diagram of the External trigger input block. It shows the flow from TIMx_AF1[17:14] and TIM_ETR (tim_etr0) through a multiplexer to tim_etr_in. This is followed by a 2-to-1 multiplexer controlled by ETP (TIMx_SMCR), then a Divider (/1, /2, /4, /8) controlled by ETPS[1:0] (TIMx_SMCR), and finally a Filter downcounter controlled by ETF[3:0] (TIMx_SMCR). The output is tim_etr, which is also labeled f_DTS. The final output is tim_etr, which goes to the Output mode controller, CK_PSC circuitry, and Slave mode controller. A reference MSv62316V2 is at the bottom right.

The tim_etr_in input comes from multiple sources: input pins (default configuration), or internal sources. The selection is done with the ETRSEL[3:0] bitfield in the TIMx_AF1 register.

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for the list of sources connected to the etr_in input in the product.

43.3.7 Clock selection

The counter clock can be provided by the following clock sources:

Internal clock source (tim_ker_ck)

If the slave mode controller is disabled (SMS = 000), then the CEN, DIR (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except UG which remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock tim_ker_ck.

Figure 426 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 426. Control circuit in normal mode, internal clock divided by 1

Timing diagram for Figure 426 showing waveforms for tim_ker_ck, CEN, UG, counter initialization (internal), tim_cnt_ck, tim_psc_ck, and Counter register values (31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07).

MSv62317V2

Timing diagram for Figure 426 showing waveforms for tim_ker_ck, CEN, UG, counter initialization (internal), tim_cnt_ck, tim_psc_ck, and Counter register values (31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07).

External clock source mode 1

This mode is selected when SMS = 111 in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.

Figure 427. tim_ti2 external clock connection example

Block diagram for Figure 427 illustrating the tim_ti2 external clock connection path through TIMx_TISEL, Filter, Edge detector, TIMx_CCER CC2P multiplexer, and TIMx_SMCR trigger selection (TS[4:0]) routing to Encoder mode, External clock mode 1, External clock mode 2, and Internal clock mode, controlled by ECE and SMS[2:0] to produce tim_psc_ck.

MSv62318V3

Block diagram for Figure 427 illustrating the tim_ti2 external clock connection path through TIMx_TISEL, Filter, Edge detector, TIMx_CCER CC2P multiplexer, and TIMx_SMCR trigger selection (TS[4:0]) routing to Encoder mode, External clock mode 1, External clock mode 2, and Internal clock mode, controlled by ECE and SMS[2:0] to produce tim_psc_ck.

1. Codes ranging from 01000 to 11111 are reserved.

For example, to configure the upcounter to count in response to a rising edge on the tim_ti2 input, use the following procedure:

  1. 1. Configure channel 2 to detect rising edges on the tim_ti2 input by writing CC2S = 01 in the TIMx_CCMR1 register.
  2. 2. Configure the input filter duration by writing the IC2F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC2F = 0000).
  3. 3. Select rising edge polarity by writing CC2P = 0 and CC2NP = 0 in the TIMx_CCER register.
  4. 4. Configure the timer in external clock mode 1 by writing SMS = 111 in the TIMx_SMCR register.
  5. 5. Select tim_ti2 as the trigger input source by writing TS = 00110 in the TIMx_SMCR register.
  6. 6. Enable the counter by writing CEN = 1 in the TIMx_CR1 register.

Note: The capture prescaler is not used for triggering, it is not necessary to configure it.

When a rising edge occurs on tim_ti2, the counter counts once and the TIF flag is set.

The delay between the rising edge on tim_ti2 and the actual clock of the counter is due to the resynchronization circuit on tim_ti2 input.

Figure 428. Control circuit in external clock mode 1

Timing diagram for Figure 428 showing the control circuit in external clock mode 1. The diagram includes five signals: tim_ti2, CEN, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. tim_ti2 is a square wave. CEN is a high signal. tim_cnt_ck and tim_psc_ck are pulses that occur on the rising edges of tim_ti2. The Counter register shows values 34, 35, and 36, incrementing on each rising edge of tim_ti2. The TIF flag is a pulse that occurs on each rising edge of tim_ti2. Arrows indicate that writing TIF=0 clears the flag.

The diagram illustrates the timing relationship between the tim_ti2 input, the counter enable signal (CEN), the counter clock (tim_cnt_ck), the prescaler clock (tim_psc_ck), the counter register value, and the TIF flag. The counter register increments on each rising edge of tim_ti2, and the TIF flag is set on each rising edge of tim_ti2. The counter clock and prescaler clock are pulses that occur on the rising edges of tim_ti2. The TIF flag is cleared by writing TIF=0.

Timing diagram for Figure 428 showing the control circuit in external clock mode 1. The diagram includes five signals: tim_ti2, CEN, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. tim_ti2 is a square wave. CEN is a high signal. tim_cnt_ck and tim_psc_ck are pulses that occur on the rising edges of tim_ti2. The Counter register shows values 34, 35, and 36, incrementing on each rising edge of tim_ti2. The TIF flag is a pulse that occurs on each rising edge of tim_ti2. Arrows indicate that writing TIF=0 clears the flag.

External clock source mode 2

This mode is selected by writing ECE = 1 in the TIMx_SMCR register.

The counter counts at each rising or falling edge on the external trigger input tim_etr_in.

The Figure 429 gives an overview of the external trigger input block.

Figure 429. External trigger input block

Block diagram of the TIMx_PSC peripheral. It shows the signal flow from TIM_ETR inputs through a multiplexer, an inverter, and another multiplexer controlled by TIMx_SMCR. The output goes to a Divider (controlled by ETPS[1:0]), then a Filter downcounter (controlled by ETF[3:0]), and finally a mode selection block (controlled by ECE and SMS[2:0]) to produce the tim_psc_ck output. The mode selection block has four inputs: Encoder mode (tim_ti1f or tim_ti2f), External clock mode 1 (tim_trgi), External clock mode 2 (tim_etrf), and Internal clock mode (tim_ker_ck).

Block diagram of the TIMx_PSC peripheral. The diagram shows the signal flow from TIM_ETR inputs through a multiplexer, an inverter, and another multiplexer controlled by TIMx_SMCR. The output goes to a Divider (controlled by ETPS[1:0]), then a Filter downcounter (controlled by ETF[3:0]), and finally a mode selection block (controlled by ECE and SMS[2:0]) to produce the tim_psc_ck output. The mode selection block has four inputs: Encoder mode (tim_ti1f or tim_ti2f), External clock mode 1 (tim_trgi), External clock mode 2 (tim_etrf), and Internal clock mode (tim_ker_ck).

Block diagram of the TIMx_PSC peripheral. It shows the signal flow from TIM_ETR inputs through a multiplexer, an inverter, and another multiplexer controlled by TIMx_SMCR. The output goes to a Divider (controlled by ETPS[1:0]), then a Filter downcounter (controlled by ETF[3:0]), and finally a mode selection block (controlled by ECE and SMS[2:0]) to produce the tim_psc_ck output. The mode selection block has four inputs: Encoder mode (tim_ti1f or tim_ti2f), External clock mode 1 (tim_trgi), External clock mode 2 (tim_etrf), and Internal clock mode (tim_ker_ck).
  1. 1. Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals.

For example, to configure the upcounter to count each 2 rising edges on tim_etr_in, use the following procedure:

  1. 1. As no filter is needed in this example, write ETF[3:0] = 0000 in the TIMx_SMCR register.
  2. 2. Set the prescaler by writing ETPS[1:0] = 01 in the TIMx_SMCR register
  3. 3. Select rising edge detection on the tim_etr_in input by writing ETP = 0 in the TIMx_SMCR register
  4. 4. Enable external clock mode 2 by writing ECE = 1 in the TIMx_SMCR register.
  5. 5. Enable the counter by writing CEN = 1 in the TIMx_CR1 register.

The counter counts once each 2 tim_etr_in rising edges.

The delay between the rising edge on tim_etr_in and the actual clock of the counter is due to the resynchronization circuit on the tim_etrp signal. As a consequence, the maximum frequency which can be correctly captured by the counter is at most \(\frac{1}{4}\) of tim_ker_ck frequency. When the ETRP signal is faster, the user must apply a division of the external signal by a proper ETPS prescaler setting.

RM0481 Advanced-control timers (TIM1/TIM8)

RM0481 Rev 5 1705/3766

Figure 430. Control circuit in external clock mode 2

Timing diagram for Figure 430 showing signals: tim_ker_ck, CEN, tim_etr_in, tim_etrp, tim_etrf, tim_cnt_ck, tim_psc_ck, and Counter register states 34, 35, 36. The diagram illustrates the relationship between the kernel clock, enable signal, external trigger input, processed external trigger, and the resulting counter clock pulses that increment the counter register.

MSv62321V1

Timing diagram for Figure 430 showing signals: tim_ker_ck, CEN, tim_etr_in, tim_etrp, tim_etrf, tim_cnt_ck, tim_psc_ck, and Counter register states 34, 35, 36. The diagram illustrates the relationship between the kernel clock, enable signal, external trigger input, processed external trigger, and the resulting counter clock pulses that increment the counter register.

43.3.8 Capture/compare channels

Each capture/compare channel is built around a capture/compare register (including a shadow register), an input stage for capture (with digital filter, multiplexing, and prescaler, except for channels 5 and 6) and an output stage (with comparator and output control).

Figure 431 to Figure 434 give an overview of one capture/compare channel.

The input stage samples the corresponding tim_tix input to generate a filtered signal tim_tixf. Then, an edge detector with polarity selection generates a signal (tim_tixfpy) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).

Figure 431. Capture/compare channel (example: channel 1 input stage)

Block diagram of the capture/compare channel input stage for channel 1. It shows the flow from TIMx_TISEL and TIM_CH1 inputs through a multiplexer, filter downcounter, edge detector, and multiplexers to produce signals like tim_ti1f_ed, tim_ic1, and tim_ic1f. Control signals like CC1P/CC1NP, tim_trc, CC1S[1:0], ICPS[1:0], and CC1E are also shown.

MSv62322V2

Block diagram of the capture/compare channel input stage for channel 1. It shows the flow from TIMx_TISEL and TIM_CH1 inputs through a multiplexer, filter downcounter, edge detector, and multiplexers to produce signals like tim_ti1f_ed, tim_ic1, and tim_ic1f. Control signals like CC1P/CC1NP, tim_trc, CC1S[1:0], ICPS[1:0], and CC1E are also shown.

The output stage generates an intermediate waveform which is then used for reference: tim_ocxref (active high). The polarity acts at the end of the chain.

Figure 432. Capture/compare channel 1 main circuit

Block diagram of Capture/compare channel 1 main circuit showing input and output modes, registers, and comparator logic.

The diagram illustrates the main circuit for Capture/compare channel 1. It is divided into three main sections: Input mode, Output mode, and the central control logic.

MSv63030V1

Block diagram of Capture/compare channel 1 main circuit showing input and output modes, registers, and comparator logic.

Figure 433. Output stage of capture/compare channel (channel 1, idem ch. 2, 3 and 4)

Block diagram of the output stage for capture/compare channels 1, 2, 3, and 4. It shows the flow from TIMx_SMCR (OCCS) through an output mode controller (TIMx_CCMR1) to an output selector. The output selector feeds into a dead-time generator (TIMx_BDTR) and multiplexers (TIMx_CCER) that select between various signals (tim_oc1ref, tim_oc1refc, tim_oc1_dt, tim_oc1n_dt) based on control bits (CC1NE, CC1E, CC1NP, MOE, OSSI, OSSR, OIS1, OIS1N). The final output passes through an output enable circuit to produce tim_oc1 and tim_oc1n. A reference note '1' points to tim_ocxref.
Block diagram of the output stage for capture/compare channels 1, 2, 3, and 4. It shows the flow from TIMx_SMCR (OCCS) through an output mode controller (TIMx_CCMR1) to an output selector. The output selector feeds into a dead-time generator (TIMx_BDTR) and multiplexers (TIMx_CCER) that select between various signals (tim_oc1ref, tim_oc1refc, tim_oc1_dt, tim_oc1n_dt) based on control bits (CC1NE, CC1E, CC1NP, MOE, OSSI, OSSR, OIS1, OIS1N). The final output passes through an output enable circuit to produce tim_oc1 and tim_oc1n. A reference note '1' points to tim_ocxref.

MSv62323V3

1. tim_ocxref, where x is the rank of the complementary channel

Figure 434. Output stage of capture/compare channel (channel 5, idem ch. 6)

Block diagram of the output stage for capture/compare channels 5 and 6. It shows the flow from TIMx_SMCR (OCCS) through an output mode controller (TIMx_CCMR3) to a multiplexer (TIMx_CCER) that selects between '0' and tim_oc5ref. This is followed by another multiplexer (TIMx_CCER) controlled by CC5P, and an output enable circuit (TIMx_BDTR) controlled by CC5E, MOE, OSSI, and OIS5 to produce the final output tim_oc5(1).
Block diagram of the output stage for capture/compare channels 5 and 6. It shows the flow from TIMx_SMCR (OCCS) through an output mode controller (TIMx_CCMR3) to a multiplexer (TIMx_CCER) that selects between '0' and tim_oc5ref. This is followed by another multiplexer (TIMx_CCER) controlled by CC5P, and an output enable circuit (TIMx_BDTR) controlled by CC5E, MOE, OSSI, and OIS5 to produce the final output tim_oc5(1).

MSv62324V3

1. Not available externally.

The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.

In capture mode, captures are actually done in the shadow register, which is copied into the preload register.

In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.

43.3.9 Input capture mode

In Input capture mode, the capture/compare registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCXIF flag was already high, then the overcapture flag CCXOF (TIMx_SR register) is set. CCXIF can be cleared by software by writing it to 0 or by reading the captured data stored in the TIMx_CCRx register. CCXOF is cleared when it is written with 0.

The following example shows how to capture the counter value in TIMx_CCR1 when tim_ti1 input rises. To do this, use the following procedure:

When an input capture occurs:

In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which may happen after reading the flag and before reading the data.

Note: IC interrupt and/or DMA requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.

43.3.10 PWM input mode

This mode is used to measure both the period and the duty cycle of a PWM signal connected to single tim_tix input:

This mode is a particular case of input capture mode. The set-up procedure is similar with the following differences:

The period and the pulsewidth of a PWM signal applied on tim_ti1 can be measured using the following procedure:

Figure 435. PWM input mode timing

Timing diagram for PWM input mode showing tim_ti1, TIMx_CNT, TIMx_CCR1, and TIMx_CCR2 signals. It illustrates IC1 capture, IC2 capture, and pulse width measurements.

The diagram illustrates the timing of PWM input mode for a timer. It shows four horizontal signal lines: tim_ti1 (input signal), TIMx_CNT (counter), TIMx_CCR1 (compare register 1), and TIMx_CCR2 (compare register 2). The TIMx_CNT line shows a sequence of values: 0004, 0000, 0001, 0002, 0003, 0004, 0000. The TIMx_CCR1 line has a constant value of 0004. The TIMx_CCR2 line has a constant value of 0002. The tim_ti1 signal is a square wave. Three events are marked with arrows pointing to the TIMx_CNT line:

The diagram is labeled MSv62325V1 in the bottom right corner.

Timing diagram for PWM input mode showing tim_ti1, TIMx_CNT, TIMx_CCR1, and TIMx_CCR2 signals. It illustrates IC1 capture, IC2 capture, and pulse width measurements.

43.3.11 Forced output mode

In output mode (CCxS bits = 00 in the TIMx_CCMRx register), each output compare signal (tim_ocxref and then tim_ocx/tim_ocxn) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.

To force an output compare signal (tim_ocxref/tim_ocx) to its active level, user just needs to write 0101 in the OCxM bits in the corresponding TIMx_CCMRx register. Thus tim_ocxref is forced high (tim_ocxref is always active high) and tim_ocx get opposite value to CCxP polarity bit.

For example: CCxP = 0 (tim_ocx active high) => tim_ocx is forced to high level.

The tim_ocxref signal can be forced low by writing the OCxM bits to 0100 in the TIMx_CCMRx register.

Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt and DMA requests can be sent accordingly. This is described in the output compare mode section below.

43.3.12 Output compare mode

This function is used to control an output waveform or indicate when a period of time has elapsed. Channels 1 to 4 can be output, while channel 5 and 6 are only available inside the microcontroller (for instance, for compound waveform generation or for ADC triggering).

When a match is found between the capture/compare register and the counter, the output compare function:

set active (OCxM = 0001), be set inactive (OCxM = 0010) or can toggle (OCxM = 0011) on match.

The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.

In output compare mode, the update event UEV has no effect on tim_ocxref and tim_ocx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One-pulse mode).

Procedure

  1. 1. Select the counter clock (internal, external, prescaler).
  2. 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
  3. 3. Set the CCxIE bit if an interrupt request is to be generated.
  4. 4. Select the output mode. For example:
    • – Write OCxM = 0011 to toggle tim_ocx output pin when CNT matches CCRx
    • – Write OCxPE = 0 to disable preload register
    • – Write CCxP = 0 to select active high polarity
    • – Write CCxE = 1 to enable the output
  5. 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.

The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE = 0, else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 436.

Figure 436. Output compare mode, toggle on tim_oc1

Timing diagram for Output compare mode, toggle on tim_oc1. The diagram shows three signals: CNT (Counter), CCR1 (Compare Register 1), and tim_oc1ref = tim_oc1 (Output signal). The CNT signal is a sequence of values: 0039, 003A, 003B, ..., B200, B201. The CCR1 signal is a constant value 003A until a match is detected, then it changes to B201. The tim_oc1ref = tim_oc1 signal is a square wave that toggles at the point where CNT matches CCR1. An arrow points from the text 'Write B201h in the CC1R register' to the point where CCR1 changes from 003A to B201. Another arrow points from the text 'Match detected on CCR1 Interrupt generated if enabled' to the point where CNT matches CCR1 (at value 003A).

Write B201h in the CC1R register

CNT: 0039, 003A, 003B, ..., B200, B201

CCR1: 003A, ..., B201

tim_oc1ref = tim_oc1

Match detected on CCR1
Interrupt generated if enabled

MSv62326V1

Timing diagram for Output compare mode, toggle on tim_oc1. The diagram shows three signals: CNT (Counter), CCR1 (Compare Register 1), and tim_oc1ref = tim_oc1 (Output signal). The CNT signal is a sequence of values: 0039, 003A, 003B, ..., B200, B201. The CCR1 signal is a constant value 003A until a match is detected, then it changes to B201. The tim_oc1ref = tim_oc1 signal is a square wave that toggles at the point where CNT matches CCR1. An arrow points from the text 'Write B201h in the CC1R register' to the point where CCR1 changes from 003A to B201. Another arrow points from the text 'Match detected on CCR1 Interrupt generated if enabled' to the point where CNT matches CCR1 (at value 003A).

43.3.13 PWM mode

Pulse width modulation mode is used to generate a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.

The PWM mode can be selected independently on each channel (one PWM per tim_ocx output) by writing 0110 (PWM mode 1) or 0111 (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. The corresponding preload register must be enabled by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the autoreload preload register (in upcounting or center-aligned modes) by setting the ARPE bit in the TIMx_CR1 register.

As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, all registers must be initialized by setting the UG bit in the TIMx_EGR register.

tim_ocx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. tim_ocx output is enabled by a combination of the CCxE, CCxNE, MOE, OSSI, and OSSR bits (TIMx_CCER and TIMx_BDTR registers). Refer to the TIMx_CCER register description for more details.

In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CCRx ≤ TIMx_CNT or TIMx_CNT ≤ TIMx_CCRx (depending on the direction of the counter).

The timer is able to generate PWM in edge-aligned mode or center-aligned mode depending on the CMS bits in the TIMx_CR1 register.

PWM edge-aligned mode

Upcounting is active when the DIR bit in the TIMx_CR1 register is low. Refer to Upcounting mode.

In the following example, the mode is PWM mode 1. The reference PWM signal tim_ocxref is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the compare value in TIMx_CCRx is greater than the autoreload value (in TIMx_ARR) then tim_ocxref is held at 1. If the compare value is zero then tim_ocxref is held at 0.

Figure 437 shows some edge-aligned PWM waveforms in an example where TIMx_ARR = 8.

Figure 437. Edge-aligned PWM waveforms (ARR = 8)

Timing diagram for edge-aligned PWM waveforms with ARR = 8. The diagram shows the Counter register counting from 0 to 8 and then wrapping to 0. For CCRx=4, tim_ocxref is high from counter 0 to 3 and low from 4 to 8. For CCRx=8, tim_ocxref is high from 0 to 7 and low from 8 to 8. For CCRx>8, tim_ocxref is held high at '1'. For CCRx=0, tim_ocxref is held low at '0'. CCxIF flags are shown as pulses at the compare events.

The figure is a timing diagram illustrating edge-aligned PWM waveforms for a timer with an autoreload value (ARR) of 8. The horizontal axis represents time, and the vertical axis shows different signals. The Counter register counts from 0 to 8, then wraps back to 0. Vertical dashed lines mark the boundaries of each counter value. The diagram shows four cases for the compare register (CCRx):

MSv62327V1

Timing diagram for edge-aligned PWM waveforms with ARR = 8. The diagram shows the Counter register counting from 0 to 8 and then wrapping to 0. For CCRx=4, tim_ocxref is high from counter 0 to 3 and low from 4 to 8. For CCRx=8, tim_ocxref is high from 0 to 7 and low from 8 to 8. For CCRx>8, tim_ocxref is held high at '1'. For CCRx=0, tim_ocxref is held low at '0'. CCxIF flags are shown as pulses at the compare events.

Downcounting is active when DIR bit in TIMx_CR1 register is high. Refer to the Downcounting mode

In PWM mode 1, the reference signal tim_ocxref is low as long as TIMx_CNT > TIMx_CCRx else it becomes high. If the compare value in TIMx_CCRx is greater than the autoreload value in TIMx_ARR, then tim_ocxref is held at 1. 0% PWM is not possible in this mode.

PWM center-aligned mode

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are different from 00 (all the remaining configurations having the same effect on the tim_ocxref/tim_oxc signals). The compare flag is set when the counter counts up, when it counts down or both when it counts up and down depending on the CMS bits configuration. The direction bit

(DIR) in the TIMx_CR1 register is updated by hardware and must not be changed by software. Refer to Center-aligned mode (up/down counting).

Figure 438 shows some center-aligned PWM waveforms in an example where:

Figure 438. Center-aligned PWM waveforms (ARR = 8)

Timing diagram for center-aligned PWM waveforms with ARR = 8. It shows the Counter register counting up from 0 to 8 and then down from 7 to 0. Four output channels are shown: CCRx=4, CCRx=7, CCRx=8, and CCRx>8. For each channel, the tim_ocxref signal and the CCxIF flag status (for CMS=01, 10, 11) are indicated. CCRx=4 has a duty cycle of 4/8. CCRx=7 has a duty cycle of 7/8. CCRx=8 is a 50% duty cycle (4/8). CCRx>8 is a 100% duty cycle. CCxIF flags are set at the start and end of the high pulse for CMS=01 and CMS=10, and at the start of the high pulse for CMS=11.

The diagram illustrates the timing of center-aligned PWM waveforms for an auto-reload register (ARR) value of 8. The counter register counts up from 0 to 8 and then counts down from 7 to 0. Four output channels are shown, each with its corresponding tim_ocxref signal and CCxIF flag status for different CMS (Capture/Compare Mode Select) settings.

MSv62328V2

Timing diagram for center-aligned PWM waveforms with ARR = 8. It shows the Counter register counting up from 0 to 8 and then down from 7 to 0. Four output channels are shown: CCRx=4, CCRx=7, CCRx=8, and CCRx>8. For each channel, the tim_ocxref signal and the CCxIF flag status (for CMS=01, 10, 11) are indicated. CCRx=4 has a duty cycle of 4/8. CCRx=7 has a duty cycle of 7/8. CCRx=8 is a 50% duty cycle (4/8). CCRx>8 is a 100% duty cycle. CCxIF flags are set at the start and end of the high pulse for CMS=01 and CMS=10, and at the start of the high pulse for CMS=11.

Hints on using center-aligned mode:

Dithering mode

The PWM mode effective resolution can be increased by enabling the dithering mode, using the DITHER bit in the TIMx_CR1 register. This applies to both the CCR (for duty cycle resolution increase) and ARR (for PWM frequency resolution increase).

The operating principle is to have the actual CCR (or ARR) value slightly changed (adding or not one timer clock period) over 16 consecutive PWM periods, with predefined patterns. This allows a 16-fold resolution increase, considering the average duty cycle or PWM period. Figure 439 presents the dithering principle applied to four consecutive PWM cycles.

Figure 439. Dithering principle

Figure 439: Dithering principle. The diagram shows five rows of PWM waveforms over four consecutive cycles. The first row is labeled 'Average duty cycle' and shows a period of 7 units and a high time of 5 units. The subsequent rows show the duty cycle being adjusted by one clock cycle (indicated by a shaded block at the end of the high pulse) to achieve fractional duty cycles: DC = 7/5, DC = (7+1/4)/5, DC = (7+1/2)/5, DC = (7+3/4)/5, and DC = 8/5. A '1 clock cycle' marker is shown at the bottom.

Average duty cycle

DC = 7/5

\(DC = (7+\frac{1}{4})/5\)

\(DC = (7+\frac{1}{2})/5\)

\(DC = (7+\frac{3}{4})/5\)

DC = 8/5

1 clock cycle

MSv45752V1

Figure 439: Dithering principle. The diagram shows five rows of PWM waveforms over four consecutive cycles. The first row is labeled 'Average duty cycle' and shows a period of 7 units and a high time of 5 units. The subsequent rows show the duty cycle being adjusted by one clock cycle (indicated by a shaded block at the end of the high pulse) to achieve fractional duty cycles: DC = 7/5, DC = (7+1/4)/5, DC = (7+1/2)/5, DC = (7+3/4)/5, and DC = 8/5. A '1 clock cycle' marker is shown at the bottom.

When the dithering mode is enabled, the register coding is changed as follows (see Figure 440 for example):

Note: The following sequence must be followed when resetting the DITHEN bit:

  1. 1. CEN and ARPE bits must be reset.
  2. 2. The DITHEN bit must be reset.
  3. 3. The CCIF flags must be cleared.
  4. 4. The CEN bit can be set ( eventually with ARPE = 1).

Figure 440. Data format and register coding in dithering mode

Figure 440: Data format and register coding in dithering mode. The diagram shows two register formats. The first, 'Register format in dithering mode', is a 20-bit register with bits b19 to b0. It is divided into an MSB 16-bit integer part and an LSB 4-bit fractional part. The second, 'Example', shows a 326-bit register with bits b19 to b0. It is divided into a 20-bit integer part and a 6-bit fractional part. Arrows point from the integer part of the example to the text 'Base compare value is 20 during 16 periods' and from the fractional part to the text 'Additional 6 cycles are spread over the 16 periods'. The reference 'MSv45753V2' is at the bottom right.

Register format in dithering mode

b19 b0

MSB: 16-bits, integer part

LSB: 4-bits fractional part

Example

b19 b0

326

20 6

Base compare value is 20 during 16 periods

Additional 6 cycles are spread over the 16 periods

MSv45753V2

Figure 440: Data format and register coding in dithering mode. The diagram shows two register formats. The first, 'Register format in dithering mode', is a 20-bit register with bits b19 to b0. It is divided into an MSB 16-bit integer part and an LSB 4-bit fractional part. The second, 'Example', shows a 326-bit register with bits b19 to b0. It is divided into a 20-bit integer part and a 6-bit fractional part. Arrows point from the integer part of the example to the text 'Base compare value is 20 during 16 periods' and from the fractional part to the text 'Additional 6 cycles are spread over the 16 periods'. The reference 'MSv45753V2' is at the bottom right.

The minimum frequency is given by the following formula:

\[\text{Resolution} = \frac{F_{\text{Tim}}}{F_{\text{pwm}}} \Rightarrow F_{\text{pwmMin}} = \frac{F_{\text{Tim}}}{\text{Max}_{\text{Resolution}}}\]

\[\text{Dithering mode disabled: } F_{\text{pwmMin}} = \frac{F_{\text{Tim}}}{65536}\]

\[\text{Dithering mode enabled: } F_{\text{pwmMin}} = \frac{F_{\text{Tim}}}{65535 + \frac{15}{16}}\]

Note: The maximum TIMx_ARR and TIMx_CCRy values are limited to 0xFFFEF in dithering mode (corresponds to 65534 for the integer part and 15 for the dithered part).

As shown on Figure 441, the dithering mode is used to increase the PWM resolution whatever the PWM frequency.

Figure 441. PWM resolution vs frequency

Graph of PWM resolution vs frequency showing Dithering and No Dithering curves.

The graph illustrates the relationship between PWM resolution and PWM frequency. The vertical axis represents PWM resolution, with marked levels at 20-bit and 16-bit. The horizontal axis represents PWM frequency, with a specific point labeled \(F_{PWM\ min}\). Two curves are shown: 'Dithering' and 'No Dithering'. Both curves start at a resolution of 20-bit at the minimum frequency \(F_{PWM\ min}\). As frequency increases, the resolution decreases for both. The 'No Dithering' curve drops more sharply, reaching a resolution of 16-bit at \(F_{PWM\ min}\) and continuing to decrease. The 'Dithering' curve decreases more gradually, maintaining a higher resolution than the 'No Dithering' curve across the frequency range. A reference code 'MSv47464V2' is located in the bottom right corner of the graph area.

Graph of PWM resolution vs frequency showing Dithering and No Dithering curves.

The duty cycle and/or period changes are spread over 16 consecutive periods, as described in Figure 442.

Figure 442. PWM dithering pattern Figure 442. PWM dithering pattern

Counter period: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

CCR1 value: 322

Compare1 value: 21 20 20 20 20 20 20 20 21 20 20 20 20 20 20 20

CCR2 value: 326

Compare2 value: 21 20 21 20 21 20 20 20 21 20 21 20 21 20 20 20

CCR3 value: 334

Compare3 value: 21 21 21 21 21 21 21 20 21 21 21 21 21 21 21 20

CCR4 value: 336

Compare4 value: 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21

ARR value: 643

Auto-Reload value: 41 40 40 40 41 40 40 40 41 40 40 40 40 40 40 40

MSv45755V1

Figure 442. PWM dithering pattern

The autoreload and compare values increments are spread following specific patterns described in Table 462. The dithering sequence is done to have increments distributed as evenly as possible and minimize the overall ripple.

Table 462. CCR and ARR register change dithering pattern
LSB valuePWM period
12345678910111213141516
0000----------------
0001+1---------------
0010+1-------+1-------
0011+1---+1---+1-------
0100+1---+1---+1---+1---
0101+1-+1-+1---+1---+1---
0110+1-+1-+1---+1-+1-+1---

Table 462. CCR and ARR register change dithering pattern (continued)

LSB valuePWM period
12345678910111213141516
0111+1-+1-+1-+1-+1-+1-+1---
1000+1-+1-+1-+1-+1-+1-+1-+1-
1001+1+1+1-+1-+1-+1-+1-+1-+1-
1010+1+1+1-+1-+1-+1+1+1-+1-+1-
1011+1+1+1-+1+1+1-+1+1+1-+1-+1-
1100+1+1+1-+1+1+1-+1+1+1-+1+1+1-
1101+1+1+1+1+1+1+1-+1+1+1-+1+1+1-
1110+1+1+1+1+1+1+1-+1+1+1+1+1+1+1-
1111+1+1+1+1+1+1+1+1+1+1+1+1+1+1+1-

The dithering mode is also available in center-aligned PWM mode (CMS bits in TIMx_CR1 register are not equal to 00). In this case, the dithering pattern is applied over eight consecutive PWM periods, considering the up and down counting phases as shown in Figure 443.

Figure 443. Dithering effect on duty cycle in center-aligned PWM mode

Figure 443 shows three diagrams illustrating the dithering effect on duty cycle in center-aligned PWM mode. Each diagram shows a triangular carrier wave and a PWM signal. The first diagram, 'No dithering', shows a standard PWM signal. The second, 'Dithering up', shows the PWM signal shifted upwards. The third, 'Dithering down', shows the PWM signal shifted downwards. The diagrams are labeled 'No dithering', 'Dithering up', and 'Dithering down' respectively. A reference code 'MSv50904V1' is visible in the bottom right corner.
Figure 443 shows three diagrams illustrating the dithering effect on duty cycle in center-aligned PWM mode. Each diagram shows a triangular carrier wave and a PWM signal. The first diagram, 'No dithering', shows a standard PWM signal. The second, 'Dithering up', shows the PWM signal shifted upwards. The third, 'Dithering down', shows the PWM signal shifted downwards. The diagrams are labeled 'No dithering', 'Dithering up', and 'Dithering down' respectively. A reference code 'MSv50904V1' is visible in the bottom right corner.

Table 463 shows how the dithering pattern is added in center-aligned PWM mode.

Table 463. CCR register change dithering pattern in center-aligned PWM mode

LSB valuePWM period
12345678
UpDnUpDnUpDnUpDnUpDnUpDnUpDnUpDn
0000----------------
0001+1---------------
0010+1-------+1-------
0011+1---+1---+1-------
0100+1---+1---+1---+1---
0101+1-+1-+1---+1---+1---
0110+1-+1-+1---+1-+1-+1---

Table 463. CCR register change dithering pattern in center-aligned PWM mode (continued)

LSB valuePWM period
12345678
UpDnUpDnUpDnUpDnUpDnUpDnUpDnUpDn
0111+1-+1-+1-+1-+1-+1-+1---
1000+1-+1-+1-+1-+1-+1-+1-+1-
1001+1+1+1-+1-+1-+1-+1-+1-+1-
1010+1+1+1-+1-+1-+1+1+1-+1-+1-
1011+1+1+1-+1+1+1-+1+1+1-+1-+1-
1100+1+1+1-+1+1+1-+1+1+1-+1+1+1-
1101+1+1+1+1+1+1+1-+1+1+1-+1+1+1-
1110+1+1+1+1+1+1+1-+1+1+1+1+1+1+1-
1111+1+1+1+1+1+1+1+1+1+1+1+1+1+1+1-

43.3.14 Asymmetric PWM mode

Asymmetric mode allows two center-aligned PWM signals to be generated with a programmable phase shift. While the frequency is determined by the value of the TIMx_ARR register, the duty cycle and the phase-shift are determined by a pair of TIMx_CCRx register. One register controls the PWM during up-counting, the second during down counting, so that PWM is adjusted every half PWM cycle:

Asymmetric PWM mode can be selected independently on two channel (one tim_ocx output per pair of CCR registers) by writing 1110 (Asymmetric PWM mode 1) or 1111 (Asymmetric PWM mode 2) in the OCxM bits in the TIMx_CCMRx register.

Note: The OCxM[3:0] bitfield is split into two parts for compatibility reasons, the most significant bit is not contiguous with the three least significant ones.

When a given channel is used as asymmetric PWM channel, its complementary channel can also be used. For instance, if an tim_oc1refc signal is generated on channel 1 (Asymmetric PWM mode 1), it is possible to output either the tim_oc2ref signal on channel 2, or an tim_oc2refc signal resulting from asymmetric PWM mode 1.

Figure 444 represents an example of signals that can be generated using asymmetric PWM mode (channels 1 to 4 are configured in asymmetric PWM mode 2). Together with the deadtime generator, this allows a full-bridge phase-shifted DC to DC converter to be controlled.

Figure 444. Generation of 2 phase-shifted PWM signals with 50% duty cycle

Timing diagram showing the generation of two phase-shifted PWM signals (tim_oc1refc and tim_oc3refc) from a counter register. The counter register counts from 0 to 8 and then back down to 0. tim_oc1refc is high from counter value 0 to 8. tim_oc3refc is high from counter value 3 to 6. CCR1=0, CCR2=8, CCR3=3, CCR4=5. Reference: MSv62329V1.

The figure is a timing diagram illustrating the generation of two phase-shifted PWM signals, tim_oc1refc and tim_oc3refc, based on a counter register. The counter register counts up from 0 to 8 and then counts down back to 0.
- tim_oc1refc(controlled by CCR1=0 and CCR2=8) is a high-level signal that remains high from counter value 0 until counter value 8, then transitions to low.
- tim_oc3refc(controlled by CCR3=3 and CCR4=5) is a high-level signal that remains high from counter value 3 until counter value 6, then transitions to low.
The diagram shows the counter register values (0, 1, 2, 3, 4, 5, 6, 7, 8, 7, 6, 5, 4, 3, 2, 1, 0, 1) and the corresponding high/low states of the two PWM signals. The reference code MSv62329V1 is noted in the bottom right corner.

Timing diagram showing the generation of two phase-shifted PWM signals (tim_oc1refc and tim_oc3refc) from a counter register. The counter register counts from 0 to 8 and then back down to 0. tim_oc1refc is high from counter value 0 to 8. tim_oc3refc is high from counter value 3 to 6. CCR1=0, CCR2=8, CCR3=3, CCR4=5. Reference: MSv62329V1.

43.3.15 Combined PWM mode

Combined PWM mode allows two edge or center-aligned PWM signals to be generated with programmable delay and phase shift between respective pulses. While the frequency is determined by the value of the TIMx_ARR register, the duty cycle and delay are determined by the two TIMx_CCRx registers. The resulting signals, tim_ocxrefc, are made of an OR or AND logical combination of two reference PWMs:

Combined PWM mode can be selected independently on two channels (one tim_ocx output per pair of CCR registers) by writing 1100 (Combined PWM mode 1) or 1101 (Combined PWM mode 2) in the OCxM bits in the TIMx_CCMRx register.

When a given channel is used as combined PWM channel, its complementary channel must be configured in the opposite PWM mode (for instance, one in Combined PWM mode 1 and the other in Combined PWM mode 2).

Note: The OCxM[3:0] bitfield is split into two parts for compatibility reasons, the most significant bit is not contiguous with the three least significant ones.

Figure 445 represents an example of signals that can be generated using combined PWM mode, obtained with the following configuration:

Figure 445. Combined PWM mode on channel 1 and 3

Figure 445: Combined PWM mode on channel 1 and 3. The figure consists of two timing diagrams. The top diagram shows Combined PWM mode 1: tim_oc1refc = tim_oc1ref OR tim_oc2ref. It displays a sawtooth ramp, two reference levels CCR1 and CCR2, and three output signals: tim_oc1ref, tim_oc2ref, and tim_oc1refc. The bottom diagram shows Combined PWM mode 2: tim_oc3refc = tim_oc3ref AND tim_oc4ref. It displays a sawtooth ramp, two reference levels CCR3 and CCR4, and three output signals: tim_oc3ref, tim_oc4ref, and tim_oc3refc. In both diagrams, the combined output signal (tim_oc1refc or tim_oc3refc) is the logical OR or AND of the two reference signals, respectively.

Combined PWM mode 1: \(tim\_oc1refc = tim\_oc1ref \text{ OR } tim\_oc2ref\)

Combined PWM mode 2: \(tim\_oc3refc = tim\_oc3ref \text{ AND } tim\_oc4ref\)

MSv74198V1

Figure 445: Combined PWM mode on channel 1 and 3. The figure consists of two timing diagrams. The top diagram shows Combined PWM mode 1: tim_oc1refc = tim_oc1ref OR tim_oc2ref. It displays a sawtooth ramp, two reference levels CCR1 and CCR2, and three output signals: tim_oc1ref, tim_oc2ref, and tim_oc1refc. The bottom diagram shows Combined PWM mode 2: tim_oc3refc = tim_oc3ref AND tim_oc4ref. It displays a sawtooth ramp, two reference levels CCR3 and CCR4, and three output signals: tim_oc3ref, tim_oc4ref, and tim_oc3refc. In both diagrams, the combined output signal (tim_oc1refc or tim_oc3refc) is the logical OR or AND of the two reference signals, respectively.

43.3.16 Combined 3-phase PWM mode

Combined 3-phase PWM mode allows one to three center-aligned PWM signals to be generated with a single programmable signal ANDed in the middle of the pulses. The tim_oc5ref signal is used to define the resulting combined signal. The 3-bits GC5C[3:1] in the TIMx_CCR5 allow selection on which reference signal the tim_oc5ref is combined. The resulting signals, tim_ocxrefc, are made of an AND logical combination of two reference PWMs:

Combined 3-phase PWM mode can be selected independently on channels 1 to 3 by setting at least one of the 3-bits GC5C[3:1].

Figure 446. 3-phase combined PWM signals with multiple trigger pulses per period Figure 446. 3-phase combined PWM signals with multiple trigger pulses per period

Diagram showing a triangular counter waveform bounded by ARR at top, with comparison levels CCR5, CCR6, CCR1, CCR4, CCR2, CCR3. Below the counter are digital waveforms: tim_oc5ref, tim_oc1refc, tim_oc2refc, tim_oc3refc, GC5C[3:0] register transitions with Preload (100, xxx, xxx) and Active (001, 100), tim_oc4ref, tim_oc6ref, and tim_trgo2 trigger pulses. Bottom right labeled MSv62331V1.

Figure 446. 3-phase combined PWM signals with multiple trigger pulses per period

The tim_trgo2 waveform shows how the ADC can be synchronized on given 3-phase PWM signals. Refer to Section 43.3.31: ADC triggers for more details.

43.3.17 Complementary outputs and dead-time insertion

The advanced-control timers (TIM1/TIM8) can output two complementary signals and manage the switching-off and the switching-on instants of the outputs.

This time is generally known as dead-time and it has to be adjusted depending on the devices that are connected to the outputs and their characteristics (such as intrinsic delays of level-shifters, or delays due to power switches).

The polarity of the outputs (main output tim_ocx or complementary tim_ocxn) can be selected independently for each output. This is done by writing to the CCxP and CCxNP bits in the TIMx_CCER register.

The complementary signals tim_ocx and tim_ocxn are activated by a combination of several control bits: the CCxE and CCxNE bits in the TIMx_CCER register and the MOE, OISx, OISxN, OSSI, and OSSR bits in the TIMx_BDTR and TIMx_CR2 registers. Refer to Table 471: Output control bits for complementary tim_ocx and tim_ocxn channels with break feature for more details. In particular, the dead-time is activated when switching to the idle state (MOE falling down to 0).

Dead-time insertion is enabled by setting both CCxE and CCxNE bits, and the MOE bit if the break circuit is present. There is one 10-bit dead-time generator for each channel. From a

reference waveform tim_ocxref, it generates two outputs tim_ocx and tim_ocxn. If tim_ocx and tim_ocxn are active high:

If the delay is greater than the width of the active output (tim_ocx or tim_ocxn) then the corresponding pulse is not generated.

The following figures show the relationships between the output signals of the dead-time generator and the reference signal tim_ocxref considering CCxP = 0, CCxNP = 0, MOE = 1, CCxE = 1 and CCxNE = 1 in these examples.

Figure 447. Complementary output with symmetrical dead-time insertion

Timing diagram for Figure 447 showing symmetrical dead-time insertion. The diagram has three horizontal signal lines: tim_ocxref (top), tim_ocx (middle), and tim_ocxn (bottom). tim_ocxref is a square wave. tim_ocx follows tim_ocxref with a delay on its rising edge, indicated by a horizontal double-headed arrow labeled 'delay' between the rising edge of tim_ocxref and the rising edge of tim_ocx. tim_ocxn is the inverse of tim_ocxref, also with a delay on its rising edge (which corresponds to the falling edge of tim_ocxref), also indicated by a horizontal double-headed arrow labeled 'delay'. Vertical dashed lines mark the edges of the signals. In the bottom right corner of the diagram area, the text 'MSv62332V1' is visible.
Timing diagram for Figure 447 showing symmetrical dead-time insertion. The diagram has three horizontal signal lines: tim_ocxref (top), tim_ocx (middle), and tim_ocxn (bottom). tim_ocxref is a square wave. tim_ocx follows tim_ocxref with a delay on its rising edge, indicated by a horizontal double-headed arrow labeled 'delay' between the rising edge of tim_ocxref and the rising edge of tim_ocx. tim_ocxn is the inverse of tim_ocxref, also with a delay on its rising edge (which corresponds to the falling edge of tim_ocxref), also indicated by a horizontal double-headed arrow labeled 'delay'. Vertical dashed lines mark the edges of the signals. In the bottom right corner of the diagram area, the text 'MSv62332V1' is visible.

The DTAE bit in the TIMx_DTR2 is used to differentiate the deadtime values for rising and falling edges of the reference signal, as shown on Figure 448.

In asymmetrical mode (DTAE = 1), the rising edge-referred deadtime is defined by the DTG[7:0] bitfield in the TIMx_BDTR register, while the falling edge-referred is defined by the DTGF[7:0] bitfield in the TIMx_DTR2 register. The DTAE bit must be written before enabling the counter and must not be modified while CEN = 1.

It is possible to have the deadtime value updated on-the-fly during pwm operation, using a preload mechanism. The deadtime bitfield DTG[7:0] and DTGF[7:0] are preloaded when the DTPE bit is set, in the TIMx_DTR2 register. The preload value is loaded in the active register on the next update event.

Note: If the DTPE bit is enabled while the counter is enabled, any new value written since last update is discarded and previous value is used.

Figure 448. Asymmetrical deadtime

Timing diagram for asymmetrical deadtime showing tim_ocxref, tim_ocx, and tim_ocxn signals for DTAE = 0 and DTAE = 1 cases.

The figure shows two sets of timing diagrams for three signals: tim_ocxref, tim_ocx, and tim_ocxn. The top set is for 'Symmetrical deadtime (DTAE = 0)' and the bottom set is for 'Asymmetrical deadtime (DTAE = 1)'. In both cases, tim_ocxref is the reference signal. tim_ocx follows tim_ocxref with a delay. tim_ocxn is the inverse of tim_ocx. In the symmetrical case, the deadtime from tim_ocxref falling to tim_ocxn rising is DTG[7:0], and from tim_ocxref rising to tim_ocxn falling is also DTG[7:0]. In the asymmetrical case, the deadtime from tim_ocxref falling to tim_ocxn rising is DTGF[7:0], and from tim_ocxref rising to tim_ocxn falling is DTG[7:0]. The label 'MSv62333V1' is at the bottom right.

Timing diagram for asymmetrical deadtime showing tim_ocxref, tim_ocx, and tim_ocxn signals for DTAE = 0 and DTAE = 1 cases.

Figure 449. Dead-time waveforms with delay greater than the negative pulse

Timing diagram for dead-time waveforms where delay is greater than the negative pulse.

The diagram shows tim_ocxref, tim_ocx, and tim_ocxn signals. tim_ocxref has a short negative pulse. tim_ocx follows tim_ocxref with a delay. tim_ocxn is the inverse of tim_ocx. A 'delay' is indicated between the falling edge of tim_ocxref and the rising edge of tim_ocxn. The label 'MSv62334V1' is at the bottom right.

Timing diagram for dead-time waveforms where delay is greater than the negative pulse.

Figure 450. Dead-time waveforms with delay greater than the positive pulse

Timing diagram for dead-time waveforms where delay is greater than the positive pulse.

The diagram shows tim_ocxref, tim_ocx, and tim_ocxn signals. tim_ocxref has a short positive pulse. tim_ocx follows tim_ocxref with a delay. tim_ocxn is the inverse of tim_ocx. A 'delay' is indicated between the rising edge of tim_ocxref and the falling edge of tim_ocxn. The label 'MSv62335V1' is at the bottom right.

Timing diagram for dead-time waveforms where delay is greater than the positive pulse.

The dead-time delay is the same for each of the channels and is programmable with the DTG bits in the TIMx_BDTR register. Refer to Section 43.6.20: TIMx break and dead-time register (TIMx_BDTR)(x = 1, 8) for delay calculation.

Redirecting tim_ocxref to tim_ocx or tim_ocxn

In output mode (forced, output compare or PWM), tim_ocxref can be redirected to the tim_ocx output or to tim_ocxn output by configuring the CCxE and CCxNE bits in the TIMx_CCER register.

This is used to send a specific waveform (such as PWM or static active level) on one output while the complementary remains at its inactive level. Other alternative possibilities are to have both outputs at inactive level or both outputs active and complementary with dead-time.

Note: When only tim_ocxn is enabled (CCxE = 0, CCxNE = 1), it is not complemented and becomes active as soon as tim_ocxref is high. For example, if CCxNP = 0 then tim_ocxn = tim_ocxref. On the other hand, when both tim_ocx and tim_ocxn are enabled (CCxE = CCxNE = 1) tim_ocx becomes active when tim_ocxref is high whereas tim_ocxn is complemented and becomes active when tim_ocxref is low.

43.3.18 Using the break function

The purpose of the break function is to protect power switches driven by PWM signals generated with the timers. The two break inputs are usually connected to fault outputs of power stages and 3-phase inverters. When activated, the break circuitry shuts down the PWM outputs and forces them to a predefined safe state. A number of internal MCU events can also be selected to trigger an output shut-down.

The break features two channels. A break channel which gathers both system-level fault (clock failure, ECC/parity errors,...) and application fault (from input pins and built-in comparator), and can force the outputs to a predefined level (either active or inactive) after a deadtime duration. A break2 channel which only includes application faults and is able to force the outputs to an inactive state.

The output enable signal and output levels during break are depending on several control bits:

When exiting from reset, the break circuit is disabled and the MOE bit is low. The break functions can be enabled by setting the BKE and BK2E bits in the TIMx_BDTR register. The break input polarities can be selected by configuring the BKP and BK2P bits in the same register. BKEx and BKPx can be modified at the same time. When the BKEx and BKPx bits are written, a delay of one APB clock cycle is applied before the writing is effective. Consequently, it is necessary to wait one APB clock period to correctly read back the bit after the write operation.

Because MOE falling edge can be asynchronous, a resynchronization circuit has been inserted between the actual signal (acting on the outputs) and the synchronous control bit (accessed in the TIMx_BDTR register). It results in some delays between the asynchronous

and the synchronous signals. In particular, if MOE is set to 1 whereas it was low, a delay must be inserted (dummy instruction) before reading it correctly. This is because the write acts on the asynchronous signal whereas the read reflects the synchronous signal.

The sources for break (tim_brk) channel are:

The sources for break2 (tim_brk2) are:

Break events can also be generated by software using BG and B2G bits in the TIMx_EGR register.

All sources are ORed before entering the timer tim_brk or tim_brk2 inputs, as per Figure 451 below.

Figure 451. Break and Break2 circuitry overview Figure 451. Break and Break2 circuitry overview

MSv62336V2

Figure 451. Break and Break2 circuitry overview

Note: An asynchronous (clockless) operation is only guaranteed when the programmable filter is disabled. If it is enabled, a fail safe clock mode (for example by using the internal PLL and/or the CSS) must be used to guarantee that break events are handled.

When one of the breaks occurs (selected level on one of the break inputs):

their active level together. Note that because of the resynchronization on MOE, the dead-time duration is slightly longer than usual (around 2 tim_cker_ck clock cycles).

Note: If the MOE is reset by the CPU while the AOE bit is set, the outputs are in idle state and forced to inactive level or Hi-Z depending on OSSI value. If both the MOE and AOE bits are reset by the CPU, the outputs are in disabled state and driven with the level programmed in the OISx bit in the TIMx_CR2 register.

The break inputs are active on level. Thus, the MOE cannot be set while the break input is active (neither automatically nor by software). In the meantime, the status flag BIF and B2IF cannot be cleared.

In addition to the break input and the output management, a write protection has been implemented inside the break circuit to safeguard the application. It is used to freeze the configuration of several parameters (dead-time duration, tim_ocx/tim_ocxn polarities and state when disabled, OCxM configurations, break enable, and polarity). The application can choose from three levels of protection selected by the LOCK bits in the TIMx_BDTR register. Refer to Section 43.6.20. The LOCK bits can be written only once after an MCU reset.

Figure 452 shows an example of behavior of the outputs in response to a break.

Figure 452. Various output behavior in response to a break event on tim_brk (OSSI = 1)

Timing diagram showing various output behaviors of tim_ocx and tim_ocxn in response to a BREAK (MOE) event. The diagram includes 12 signal traces. The first trace is the BREAK (MOE) signal, which transitions from low to high. The subsequent traces show the behavior of tim_ocx and tim_ocxn under different configuration conditions. For tim_ocx, the behavior depends on OISx (0 or 1) and CCxP (0 or 1). For tim_ocxn, the behavior depends on a combination of CCxE, CCxP, OISx, CCxNE, CCxNP, and OISxN. Delays are indicated by horizontal double-headed arrows between the BREAK event and the output transitions.

Figure 452 illustrates the various output behaviors of tim_ocx and tim_ocxn in response to a break event on tim_brk(OSSI = 1). The diagram shows the timing relationship between the BREAK (MOE) signal and the timer outputs under different configuration conditions.

The diagram includes the following signal traces:

MSv62337V1

Timing diagram showing various output behaviors of tim_ocx and tim_ocxn in response to a BREAK (MOE) event. The diagram includes 12 signal traces. The first trace is the BREAK (MOE) signal, which transitions from low to high. The subsequent traces show the behavior of tim_ocx and tim_ocxn under different configuration conditions. For tim_ocx, the behavior depends on OISx (0 or 1) and CCxP (0 or 1). For tim_ocxn, the behavior depends on a combination of CCxE, CCxP, OISx, CCxNE, CCxNP, and OISxN. Delays are indicated by horizontal double-headed arrows between the BREAK event and the output transitions.

The two break inputs have different behaviors on timer outputs:

The tim_brk has a higher priority than tim_brk2 input, as described in Table 464.

Note: tim_brk2 must only be used with OSSR = OSSI = 1.

Table 464. Behavior of timer outputs versus tim_brk/tim_brk2 inputs

tim_brktim_brk2Timer outputs stateTypical use case
tim_ocxn output
(low side switches)
tim_ocx output
(high side switches)
ActiveX
  • Inactive then forced output state (after a deadtime)
  • Outputs disabled if OSSI = 0(control taken over by GPIO logic)
ON after deadtime insertionOFF
InactiveActiveInactiveOFFOFF

Figure 453 gives an example of tim_ocx and tim_ocxn output behavior in case of active signals on tim_brk and tim_brk2 inputs. In this case, both outputs have active high polarities (CCxP = CCxNP = 0 in TIMx_CCER register).

Figure 453. PWM output state following tim_brk and tim_brk2 assertion (OSSI = 1)

Timing diagram showing the behavior of tim_brk2, tim_brk, tim_ocx, and tim_ocxn signals. tim_brk2 is high, then transitions to low. tim_brk is high, then transitions to low. tim_ocx and tim_ocxn are high, then transition to low after a deadtime delay following the assertion of tim_brk and tim_brk2. The I/O state is Active, then Inactive, then Idle.

The diagram illustrates the timing relationship between the tim_brk2, tim_brk, tim_ocx, and tim_ocxn signals. tim_brk2 is high, then transitions to low. tim_brk is high, then transitions to low. tim_ocx and tim_ocxn are high, then transition to low after a deadtime delay following the assertion of tim_brk and tim_brk2. The I/O state is Active, then Inactive, then Idle. The deadtime is indicated by a double-headed arrow between the assertion of tim_brk and tim_brk2 and the assertion of tim_ocx and tim_ocxn. The I/O state is labeled as Active, Inactive, and Idle. The diagram is labeled MSv62338V1.

Timing diagram showing the behavior of tim_brk2, tim_brk, tim_ocx, and tim_ocxn signals. tim_brk2 is high, then transitions to low. tim_brk is high, then transitions to low. tim_ocx and tim_ocxn are high, then transition to low after a deadtime delay following the assertion of tim_brk and tim_brk2. The I/O state is Active, then Inactive, then Idle.

Figure 454. PWM output state following tim_brk assertion (OSSI = 0)

Timing diagram showing the relationship between tim_brk, tim_ocx, and tim_ocxn signals. The diagram is divided into three phases: Active, Inactive, and Disabled. In the Active phase, tim_ocx and tim_ocxn are high. In the Inactive phase, which follows a 'Deadtime' period after tim_brk assertion, both outputs are low. In the Disabled phase, the outputs return to their default GPIO states (HI-Z).

The diagram illustrates the PWM output state following a tim_brk assertion when OSSI = 0. It shows three signals: tim_brk, tim_ocx, and tim_ocxn. The tim_brk signal transitions from low to high. The tim_ocx and tim_ocxn signals transition from high to low after a 'Deadtime' interval following the tim_brk assertion. The I/O state is categorized into three periods: 'Active' (before the deadtime), 'Inactive' (during the deadtime and while outputs are low), and 'Disabled' (after the outputs return to HI-Z). The I/O state during the Disabled period is defined by the GPIO controller (HI-Z). The diagram is labeled MSv62339V1.

Timing diagram showing the relationship between tim_brk, tim_ocx, and tim_ocxn signals. The diagram is divided into three phases: Active, Inactive, and Disabled. In the Active phase, tim_ocx and tim_ocxn are high. In the Inactive phase, which follows a 'Deadtime' period after tim_brk assertion, both outputs are low. In the Disabled phase, the outputs return to their default GPIO states (HI-Z).

43.3.19 Bidirectional break inputs

The TIM1/TIM8 feature bidirectional break I/Os, as represented on Figure 455.

This provides support for:

The tim_brk and tim_brk2 inputs are configured in bidirectional mode using the BKBID and BK2BID bits in the TIMxBDTR register. The BKBID programming bits can be locked in read-only mode using the LOCK bits in the TIMxBDTR register (in LOCK level 1 or above).

The bidirectional mode is available for both the tim_brk and tim_brk2 inputs, and require the I/O to be configured in open-drain mode with active low polarity (using BKINP, BKP, BK2INP and BK2P bits). Any break request coming either from system (for example CSS), from on-chip peripherals, or from break inputs forces a low level on the break input to signal the fault event. The bidirectional mode is inhibited if the polarity bits are not correctly set (active high polarity), for safety purposes.

The break software events (BG and B2G) also cause the break I/O to be forced to 0 to indicate to the external components that the timer is entered in break state. However, this is valid only if the break is enabled (BKE or B2KE= 1). When a software break event is generated with BKE or B2KE= 0, the outputs are put in safe state and the break flag is set, but there is no effect on the TIMx_BKIN and TIMx_BKIN2 I/Os.

A safe disarming mechanism prevents the system to be definitively locked-up (a low level on the break input triggers a break which enforces a low level on the same input).

When the BKDSRM(BK2DSRM) bit is set to 1, this releases the break output to clear a fault signal and to give the possibility to re-arm the system.

At no point the break protection circuitry can be disabled:

Table 465. Break protection disarming conditions

MOEBKBID
(BK2BID)
BKDSRM
(BK2DSRM)
Break protection state
00XArmed
010Armed
011Disarmed
1XXArmed

Arming and rearming break circuitry

The break circuitry (in input or bidirectional mode) is armed by default (peripheral reset configuration).

The following procedure must be followed to re-arm the protection after a break (break2) event:

From this point, the break circuitry is armed and active, and the MOE bit can be set to re-enable the PWM outputs.

Figure 455. Output redirection (tim_brk2 request not represented)

Block diagram of output redirection logic for break protection. It shows the flow from break inputs through an AF controller, logic gates (OR, AND, NAND), and a filter to generate the tim_brk signal. It also shows the interaction with the Bidirectional mode control logic and various flags like SBIF and BIF.

The diagram illustrates the output redirection logic for break protection. Key components and signals include:

MSv62340V2

Block diagram of output redirection logic for break protection. It shows the flow from break inputs through an AF controller, logic gates (OR, AND, NAND), and a filter to generate the tim_brk signal. It also shows the interaction with the Bidirectional mode control logic and various flags like SBIF and BIF.

43.3.20 Clearing the tim_ocxref signal on an external event

The tim_ocxref signal of a given channel can be cleared when a high level is applied on the tim_ocref_clr_int input (OCxCE enable bit in the corresponding TIMx_CCMRx register set to 1). tim_ocxref remains low until the next transition to the active state, on the following PWM

cycle. This function can only be used in Output compare and PWM modes. It does not work in Forced mode. tim_ocref_clr_int input can be selected between the tim_ocref_clr input and tim_etr(tim_etr_in after the filter) by configuring the OCCS bit in the TIMx_SMCR register.

The tim_ocref_clr input can be selected among several inputs, using the OCRSEL[2:0] bitfield in the TIMx_AF2 register, as shown on the Figure 456 below. Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for a list of sources available in the product.

Figure 456. tim_ocref_clr input selection multiplexer

Block diagram of the tim_ocref_clr input selection multiplexer. It shows two multiplexers. The first multiplexer, controlled by TIMx_AF2 OCRSEL[2:0], selects one of eight inputs (tim_ocref_clr0 to tim_ocref_clr7) to produce the tim_ocref_clr signal. The second multiplexer, controlled by TIMx_SMCR OCCS, selects between the tim_ocref_clr signal and the tim_etr signal to produce the final tim_ocref_clr_int signal.
graph LR
    subgraph TIMx_AF2
        OCRSEL[OCRSEL[2:0]]
    end
    subgraph TIMx_SMCR
        OCCS
    end
    inputs[tim_ocref_clr0
tim_ocref_clr1
tim_ocref_clr2
tim_ocref_clr3
tim_ocref_clr4
tim_ocref_clr5
tim_ocref_clr6
tim_ocref_clr7] --> M1{ } M1 --> tim_ocref_clr tim_etr --> M2{ } tim_ocref_clr --> M2 M2 --> tim_ocref_clr_int OCRSEL --- M1 OCCS --- M2

MSv62341V2

Block diagram of the tim_ocref_clr input selection multiplexer. It shows two multiplexers. The first multiplexer, controlled by TIMx_AF2 OCRSEL[2:0], selects one of eight inputs (tim_ocref_clr0 to tim_ocref_clr7) to produce the tim_ocref_clr signal. The second multiplexer, controlled by TIMx_SMCR OCCS, selects between the tim_ocref_clr signal and the tim_etr signal to produce the final tim_ocref_clr_int signal.

When tim_etr is chosen, tim_etr_in must be configured as follows:

  1. 1. The external trigger prescaler must be kept off: bits ETPS[1:0] of the TIMx_SMCR register set to 00.
  2. 2. The external clock mode 2 must be disabled: bit ECE of the TIMx_SMCR register set to 0.
  3. 3. The external trigger polarity (ETP) and the external trigger filter (ETF) can be configured according to application needs (as per polarity of the source connected to the trigger and eventual need to remove noise using the filter).

Figure 457 shows the behavior of the tim_ocxref signal when the tim_etr input becomes high, for both values of the enable bit OCxCE. In this example, the timer TIMx is programmed in PWM mode.

Figure 457. Clearing TIMx tim_ocxref

Timing diagram showing the clearing of TIMx tim_ocxref. The diagram includes four signals: Counter (CNT), tim_etr, tim_ocxref (OCxCE = '0'), and tim_ocxref (OCxCE = '1'). The Counter (CNT) is a sawtooth wave with a threshold (CCRx) indicated by a dashed line. The tim_etr signal is a pulse that triggers the clearing of the counter. The tim_ocxref (OCxCE = '0') signal is a pulse that clears the counter. The tim_ocxref (OCxCE = '1') signal is a pulse that clears the counter. Two arrows point to the tim_ocxref (OCxCE = '1') signal, labeled 'tim_ocref_clr_int becomes high' and 'tim_ocref_clr_int still high'.

MSv62342V1

Timing diagram showing the clearing of TIMx tim_ocxref. The diagram includes four signals: Counter (CNT), tim_etr, tim_ocxref (OCxCE = '0'), and tim_ocxref (OCxCE = '1'). The Counter (CNT) is a sawtooth wave with a threshold (CCRx) indicated by a dashed line. The tim_etr signal is a pulse that triggers the clearing of the counter. The tim_ocxref (OCxCE = '0') signal is a pulse that clears the counter. The tim_ocxref (OCxCE = '1') signal is a pulse that clears the counter. Two arrows point to the tim_ocxref (OCxCE = '1') signal, labeled 'tim_ocref_clr_int becomes high' and 'tim_ocref_clr_int still high'.

Note: In case of a PWM with a 100% duty cycle (if CCRx>ARR), then tim_ocxref is enabled again at the next counter overflow.

43.3.21 6-step PWM generation

When complementary outputs are used on a channel, preload bits are available on the OCxM, CCxE, and CCxNE bits. The preload bits are transferred to the shadow bits at the COM commutation event. Thus one can program in advance the configuration for the next step and change the configuration of all the channels at the same time. COM can be generated by software by setting the COM bit in the TIMx_EGR register or by hardware (on tim_trgi rising edge).

A flag is set when the COM event occurs (COMIF bit in the TIMx_SR register), which can generate an interrupt (if the COMIE bit is set in the TIMx_DIER register) or a DMA request (if the COMDE bit is set in the TIMx_DIER register).

Figure 458 describes the behavior of the tim_ocx and tim_ocxn outputs when a COM event occurs, in three different examples of programmed configurations.

Figure 458. 6-step generation, COM example (OSSR = 1)

Timing diagram for 6-step generation, COM example (OSSR = 1). The diagram shows the relationship between Counter (CNT), tim_ocxref, COM event, and output signals tim_ocx and tim_ocxn for three examples. Example 1 shows a transition from forced inactive to active. Example 2 shows a transition from active to inactive. Example 3 shows a transition from active to active with a different duty cycle. Annotations indicate register writes for CCxE, CCxNE, and OCxM.

The diagram illustrates the 6-step generation process for the COM (Complementary Output Mode) example where OSSR = 1. It shows the timing of the Counter (CNT), the reference signal (tim_ocxref), the COM event, and the output signals (tim_ocx and tim_ocxn) for three different examples.

Example 1: Shows the transition from a forced inactive state to an active state. The initial configuration is CCxE = 1, CCxNE = 0, and OCxM = 0010 (forced inactive). A write to OCxM to 0100 is performed. The final configuration is CCxE = 1, CCxNE = 0, and OCxM = 0100.

Example 2: Shows the transition from an active state to a forced inactive state. The initial configuration is CCxE = 1, CCxNE = 0, and OCxM = 0100 (forced inactive). A write to CCxNE to 1 and OCxM to 0101 is performed. The final configuration is CCxE = 0, CCxNE = 1, and OCxM = 0101.

Example 3: Shows the transition from an active state to an active state with a different duty cycle. The initial configuration is CCxE = 1, CCxNE = 0, and OCxM = 0010 (forced inactive). A write to CCxNE to 0 and OCxM to 0100 is performed. The final configuration is CCxE = 1, CCxNE = 1, and OCxM = 0100.

MSv62343V1

Timing diagram for 6-step generation, COM example (OSSR = 1). The diagram shows the relationship between Counter (CNT), tim_ocxref, COM event, and output signals tim_ocx and tim_ocxn for three examples. Example 1 shows a transition from forced inactive to active. Example 2 shows a transition from active to inactive. Example 3 shows a transition from active to active with a different duty cycle. Annotations indicate register writes for CCxE, CCxNE, and OCxM.

43.3.22 One-pulse mode

One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.

Starting the counter can be controlled through the slave mode controller. Generating the waveform can be done in output compare mode or PWM mode. One-pulse mode is selected by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.

A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting (when the timer is waiting for the trigger), the configuration must be:

Figure 459. Example of one pulse mode.

Timing diagram for one pulse mode showing the relationship between tim_ti2, tim_oc1ref, tim_oc1, and the Counter (TIMx_ARR and TIMx_CCR1).

The diagram illustrates the timing for one pulse mode. It shows four signals over time: tim_ti2, tim_oc1ref, tim_oc1, and the Counter (with levels TIMx_ARR and TIMx_CCR1). A rising edge on tim_ti2 triggers the counter to start at 0. The counter increments in steps. The time from the trigger to the first compare match at TIMx_CCR1 is labeled \(t_{DELAY}\). At this point, tim_oc1ref transitions from low to high, and tim_oc1 transitions from low to high. The counter continues to increment until it reaches TIMx_ARR. The time from the first compare match to the counter reaching TIMx_ARR is labeled \(t_{PULSE}\). At this point, tim_oc1ref transitions from high to low, and tim_oc1 transitions from high to low. The counter then rolls over to 0. The horizontal axis is labeled t. The reference ID MSv62344V1 is in the bottom right corner.

Timing diagram for one pulse mode showing the relationship between tim_ti2, tim_oc1ref, tim_oc1, and the Counter (TIMx_ARR and TIMx_CCR1).

In the following example, the user wants to generate a positive pulse on tim_oc1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\) as soon as a positive edge is detected on the tim_ti2 input pin.

Use tim_ti2fp2 as trigger 1:

The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).

In this example, the DIR and CMS bits in the TIMx_CR1 register must be low.

Since only one pulse (Single mode) is needed, a 1 must be written in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over

from the autoreload value back to 0). When OPM bit in the TIMx_CR1 register is set to 0, so the Repetitive mode is selected.

Particular case: tim_ocx fast enable:

In One-pulse mode, the edge detection on tim_tix input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{DELAY\ min}\) that can be achieved.

To output a waveform with the minimum delay, the OCxFE bit can be set in the TIMx_CCMRx register. Then tim_ocxref (and tim_ocx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.

43.3.23 Retriggerable One-pulse mode

This mode allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length, but with the following differences with nonretriggerable one-pulse mode described in Section 43.3.22:

The timer must be in Slave mode, with the bits SMS[3:0] = 1000 (Combined Reset + trigger mode) in the TIMx_SMCR register, and the OCxM[3:0] bits set to 1000 or 1001 for retriggerable OPM mode 1 or 2.

If the timer is configured in Up-counting mode, the corresponding CCRx must be set to 0 (the ARR register sets the pulse length). If the timer is configured in Down-counting mode, CCRx must be above or equal to ARR.

Note: The OCxM[3:0] and SMS[3:0] bitfields are split into two parts for compatibility reasons, the most significant bit are not contiguous with the three least significant ones.

This mode must not be used with center-aligned PWM modes. It is mandatory to have CMS[1:0] = 00 in TIMx_CR1.

Figure 460. Retriggerable one-pulse mode

Timing diagram for Retriggerable one-pulse mode showing tim_trgi, Counter, and tim_ocx signals.

The diagram illustrates the retriggerable one-pulse mode operation. It shows three signals over time: tim_trgi (trigger input), Counter (timer counter), and tim_ocx (output compare signal).

MSv62345V2

Timing diagram for Retriggerable one-pulse mode showing tim_trgi, Counter, and tim_ocx signals.

43.3.24 Pulse on compare mode

A pulse can be generated upon compare match event. A signal with a programmable pulsewidth generated when the counter value equals a given compare value, for debugging or synchronization purposes.

This mode is available for any slave mode selection, including encoder modes, in edge and center aligned counting modes. It is solely available for channel 3 and channel 4. The pulse generator is unique and is shared by the two channels, as shown on Figure 461.

Figure 461. Pulse generator circuitry

Figure 461: Pulse generator circuitry block diagram. Shows CCR3 match and CCR4 match inputs passing into Enable blocks controlled by OC3M = 1010 and OC4M = 1010 respectively. Their outputs enter an OR gate, which triggers the Pulse generator (configured by PWPRSC[2:0] and PW[7:0]) and connects to the Set inputs of two R/S latches. The pulse generator output resets the upper R/S latch through a falling-edge/polarity block, and resets the lower R/S latch. The latch outputs along with enable lines pass to output AND gates producing tim_oc3 and tim_oc4 signals.
Figure 461: Pulse generator circuitry block diagram. Shows CCR3 match and CCR4 match inputs passing into Enable blocks controlled by OC3M = 1010 and OC4M = 1010 respectively. Their outputs enter an OR gate, which triggers the Pulse generator (configured by PWPRSC[2:0] and PW[7:0]) and connects to the Set inputs of two R/S latches. The pulse generator output resets the upper R/S latch through a falling-edge/polarity block, and resets the lower R/S latch. The latch outputs along with enable lines pass to output AND gates producing tim_oc3 and tim_oc4 signals.

Figure 462 shows how the pulse is generated for edge-aligned and encoder operating modes.

Figure 462. Pulse generation on compare event, for edge-aligned and encoder modes

Figure 462: Pulse generation on compare event, for edge-aligned and encoder modes. The figure consists of two timing diagrams. The top diagram shows edge-aligned mode with a counter ramping up, a CMP3 threshold, triggers at compare events, and a resulting tim_ocx pulse. A re-trigger event is shown extending the pulse width. The bottom diagram shows encoder mode with a counter ramping up and then down, CMP3 threshold, triggers, and a resulting tim_ocx pulse.

The figure contains two timing diagrams illustrating pulse generation on compare events.

Top Diagram (Edge-aligned mode): Shows a counter ramping up. A horizontal dashed line represents the CMP3 threshold. Vertical dashed lines with arrows pointing down represent triggers. The output signal tim_ocx is a pulse that starts at the first trigger and ends when the counter reaches the CMP3 threshold. A second trigger occurs while the first pulse is still ongoing, causing the pulse to be extended until the counter again reaches the CMP3 threshold. This extension is labeled "Extended pulsewidth due to re-trigger".

Bottom Diagram (Encoder mode): Shows a counter ramping up and then ramping down. A horizontal dashed line represents the CMP3 threshold. Vertical dashed lines with arrows pointing down represent triggers. The output signal tim_ocx is a pulse that starts at the first trigger and ends when the counter reaches the CMP3 threshold. A second trigger occurs while the first pulse is still ongoing, causing the pulse to be extended until the counter again reaches the CMP3 threshold.

MSv62347V1

Figure 462: Pulse generation on compare event, for edge-aligned and encoder modes. The figure consists of two timing diagrams. The top diagram shows edge-aligned mode with a counter ramping up, a CMP3 threshold, triggers at compare events, and a resulting tim_ocx pulse. A re-trigger event is shown extending the pulse width. The bottom diagram shows encoder mode with a counter ramping up and then down, CMP3 threshold, triggers, and a resulting tim_ocx pulse.

This output compare mode is selected using the OC3M[3:0] and OC4M[3:0] bitfields in TIMx_CCMR2 register.

The pulsewidth is programmed using the PW[7:0] bitfield in the register, using a specific clock prescaled according to PWPRSC[2:0] bits, as follows:

\[t_{PW} = PW[7:0] \times t_{PWG}\]

\[\text{where } t_{PWG} = (2^{(PWPRSC[2:0])}) \times t_{tim\_ker\_ck}\]

gives the resolution and maximum values depending on the prescaler value.

The pulse is retriggerable: a new trigger while the pulse is ongoing, causes the pulse to be extended.

Note: If the two channels are enabled simultaneously, the pulses are issued independently as long as the trigger on one channel is not overlapping the pulse generated on the concurrent output. On the opposite, if the two triggers are overlapping, the pulse width related to the first arriving trigger is extended (because of the retrigger), while the pulse width of the last arriving trigger is correct (as shown on Figure 463).

Figure 463. Extended pulsewidth in case of concurrent triggers

Timing diagram showing Trigger CMP3, Trigger CMP4, tim_oc3, and tim_oc4 signals. Trigger CMP3 and Trigger CMP4 are shown as vertical dashed lines with downward arrows. tim_oc3 is a square wave that is high when Trigger CMP3 is active. tim_oc4 is a square wave that is high when Trigger CMP4 is active. A dashed box highlights an overlapping region where both triggers are active, and a label points to it: 'Extended pulsewidth due to overlapping CMP4 trigger'.

The diagram illustrates the interaction between two triggers (CMP3 and CMP4) and their corresponding output signals (tim_oc3 and tim_oc4). Trigger CMP3 is shown as a vertical dashed line with a downward arrow, indicating a trigger event. Similarly, Trigger CMP4 is shown as a vertical dashed line with a downward arrow. The tim_oc3 signal is a square wave that is high when Trigger CMP3 is active. The tim_oc4 signal is a square wave that is high when Trigger CMP4 is active. A dashed box highlights an overlapping region where both triggers are active, and a label points to it: 'Extended pulsewidth due to overlapping CMP4 trigger'.

Timing diagram showing Trigger CMP3, Trigger CMP4, tim_oc3, and tim_oc4 signals. Trigger CMP3 and Trigger CMP4 are shown as vertical dashed lines with downward arrows. tim_oc3 is a square wave that is high when Trigger CMP3 is active. tim_oc4 is a square wave that is high when Trigger CMP4 is active. A dashed box highlights an overlapping region where both triggers are active, and a label points to it: 'Extended pulsewidth due to overlapping CMP4 trigger'.

43.3.25 Encoder interface mode

Quadrature encoder

To select Encoder Interface mode write SMS = 0001 in the TIMx_SMCR register if the counter is counting on tim_ti1 edges only, SMS = 0010 if it is counting on tim_ti2 edges only and SMS = 0011 if it is counting on both tim_ti1 and tim_ti2 edges.

Select the tim_ti1 and tim_ti2 polarity by programming the CC1P and CC2P bits in the TIMx_CCER register. When needed, the input filter can be programmed as well. CC1NP and CC2NP must be kept low.

The two inputs tim_ti1 and tim_ti2 are used to interface to a quadrature encoder. Refer to Table 466. The counter is clocked by each valid transition on tim_ti1fp1 or tim_ti2fp2 (tim_ti1 and tim_ti2 after input filter and polarity selection, tim_ti1fp1 = tim_ti1 if not filtered and not inverted, tim_ti2fp2 = tim_ti2 if not filtered and not inverted) assuming that it is enabled (CEN bit in TIMx_CR1 register written to 1). The sequence of transitions of the two inputs is evaluated and generates count pulses as well as the direction signal. Depending on the sequence the counter counts up or down, the DIR bit in the TIMx_CR1 register is modified by hardware accordingly. The DIR bit is calculated at each transition on any input (tim_ti1 or tim_ti2), whatever the counter is counting on tim_ti1 only, tim_ti2 only or both tim_ti1 and tim_ti2.

Encoder interface mode acts simply as an external clock with direction selection. This means that the counter just counts continuously between 0 and the autoreload value in the TIMx_ARR register (0 to ARR or ARR down to 0 depending on the direction). So the TIMx_ARR must be configured before starting. In the same way, the capture, compare, prescaler, repetition counter, trigger output features continue to work as normal. Encoder mode and External clock mode 2 are not compatible and must not be selected together.

In this mode, the counter is modified automatically following the speed and the direction of the quadrature encoder and its content, therefore, always represents the encoder's position. The count direction correspond to the rotation direction of the connected sensor. The table summarizes the possible combinations, assuming tim_ti1 and tim_ti2 do not switch at the same time.

Table 466. Counting direction versus encoder signals (CC1P = CC2P = 0)

Active edgeSMS[3:0]Level on opposite signal
(tim_ti1fp1 for tim_ti2,
tim_ti2fp2 for tim_ti1)
tim_ti1fp1 signaltim_ti2fp2 signal
RisingFallingRisingFalling
Counting on tim_ti1 only
x1 mode
1110HighDownUpNo countNo count
LowNo countNo countNo countNo count
Counting on tim_ti2 only
x1 mode
1111HighNo countNo countUpDown
LowNo countNo countNo countNo count
Counting on tim_ti1 only
x2 mode
0001HighDownUpNo countNo count
LowUpDownNo countNo count
Counting on tim_ti2 only
x2 mode
0010HighNo countNo countUpDown
LowNo countNo countDownUp
Counting on tim_ti1 and tim_ti2
x4 mode
0011HighDownUpUpDown
LowUpDownDownUp

A quadrature encoder can be connected directly to the MCU without external interface logic. However, comparators are normally be used to convert the encoder's differential outputs to digital signals. This greatly increases noise immunity. The third encoder output which indicate the mechanical zero position, may be connected to the external trigger input and trigger a counter reset.

Figure 464 gives an example of counter operation, showing count signal generation and direction control. It also shows how input jitter is compensated where both edges are selected. This might occur if the sensor is positioned near to one of the switching points. For this example the configuration is the following:

Figure 464. Example of counter operation in encoder interface mode.

Figure 464: Example of counter operation in encoder interface mode. The diagram illustrates signals tim_ti1, tim_ti2, and the Counter staircase waveform through five stages: forward (counting up), jitter, backward (counting down), jitter, and forward (counting up). Reference: MSv62349V1.
Figure 464: Example of counter operation in encoder interface mode. The diagram illustrates signals tim_ti1, tim_ti2, and the Counter staircase waveform through five stages: forward (counting up), jitter, backward (counting down), jitter, and forward (counting up). Reference: MSv62349V1.

Figure 465 gives an example of counter behavior when tim_ti1fp1 polarity is inverted (same configuration as above except CC1P = 1).

Figure 465. Example of encoder interface mode with tim_ti1fp1 polarity inverted.

Figure 465: Example of encoder interface mode with tim_ti1fp1 polarity inverted. The diagram illustrates signals tim_ti1, tim_ti2, and the Counter staircase waveform through five stages: forward (counting down), jitter, backward (counting up), jitter, and forward (counting down). Reference: MSv62350V1.
Figure 465: Example of encoder interface mode with tim_ti1fp1 polarity inverted. The diagram illustrates signals tim_ti1, tim_ti2, and the Counter staircase waveform through five stages: forward (counting down), jitter, backward (counting up), jitter, and forward (counting down). Reference: MSv62350V1.

Figure 466 shows the timer counter value during a speed reversal, for various counting modes.

Figure 466. Quadrature encoder counting modes

Timing diagram for Quadrature encoder counting modes showing tim_ti1, tim_ti2, DIR bit, Counter x4, Counter x2, and Counter x1 signals.

The diagram illustrates the timing relationship between the quadrature encoder inputs and the counter outputs. The signals are shown as follows:

MSv62351V1

Timing diagram for Quadrature encoder counting modes showing tim_ti1, tim_ti2, DIR bit, Counter x4, Counter x2, and Counter x1 signals.

The timer, when configured in Encoder Interface mode provides information on the sensor's current position. Dynamic information can be obtained (speed, acceleration, deceleration) by measuring the period between two encoder events using a second timer configured in capture mode. The output of the encoder which indicates the mechanical zero can be used for this purpose. Depending on the time between two events, the counter can also be read at regular times. This can be done by latching the counter value into a third input capture register if available (then the capture signal must be periodic and can be generated by another timer). When available, it is also possible to read its value through a DMA request.

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag (UIF) into the timer counter register's bit 31 (TIMxCNT[31]). This allows both the counter value and a potential roll-over condition signaled by the UIFCPY flag to be read in an atomic way. It eases the calculation of angular speed by avoiding race conditions caused, for instance, by a processing shared between a background task (counter reading) and an interrupt (update interrupt).

There is no latency between the UIF and UIFCPY flag assertions.

In 32-bit timer implementations, when the IUFREMAP bit is set, bit 31 of the counter is overwritten by the UIFCPY flag upon read access (the counter's most significant bit is only accessible in write mode).

Clock plus direction encoder mode

In addition to the quadrature encoder mode, the timer offers support for other types of encoders.

In the clock plus direction mode shown on Figure 467, the clock is provided on a single line, on tim_ti2, while the direction is forced using the tim_ti1 input.

This mode is enabled with the SMS[3:0] bitfield in the TIMx_SMCR register, as following:

The polarity of the direction signal on tim_ti1 is set with the CC1P bit: 0 corresponds to positive polarity (up-counting when tim_ti1 is high and down-counting when tim_ti1 is low) and CC1P= 1 corresponds to negative polarity (up-counting when tim_ti1 is low).

Figure 467. Direction plus clock encoder mode

Timing diagram for Direction plus clock encoder mode showing tim_ti1, tim_ti2, Counter x2 mode, and Counter x1 mode signals.

The diagram illustrates the Direction plus clock encoder mode. It shows four signals over time: tim_ti1, tim_ti2, Counter x2 mode, and Counter x1 mode. tim_ti1 is a high-level signal that transitions to low. tim_ti2 is a square wave. The Counter x2 mode signal shows a sequence of values: 6, 7, 8, 9, 10, 11, 10, 9, 8, 7, 6. The Counter x1 mode signal shows a sequence of values: 6, 7, 8, 9, 8, 7. The transition from 11 to 10 in Counter x2 mode corresponds to the falling edge of tim_ti1.

Timing diagram for Direction plus clock encoder mode showing tim_ti1, tim_ti2, Counter x2 mode, and Counter x1 mode signals.

Directional clock encoder mode

In the directional clock mode on Figure 468, the clocks are provided on two lines, with a single one at once, depending on the direction, so as to have one up-counting clock line and one down-counting clock line.

This mode is enabled with the SMS[3:0] bitfield in the TIMx_SMCR register, as following:

Figure 468. Directional clock encoder mode (CC1P = CC2P = 0)

Timing diagram for Directional clock encoder mode (CC1P = CC2P = 0) showing tim_ti1, tim_ti2, DIR bit, Counter x2 mode, and Counter x1 mode signals.

The diagram illustrates the Directional clock encoder mode with CC1P = CC2P = 0. It shows five signals over time: tim_ti1, tim_ti2, DIR bit, Counter x2 mode, and Counter x1 mode. tim_ti1 and tim_ti2 are square waves. The DIR bit is high during the first half of the sequence and low during the second half. The Counter x2 mode signal shows a sequence of values: 6, 7, 8, 9, 10, 11, 10, 9, 8, 7, 6, 5. The Counter x1 mode signal shows a sequence of values: 6, 7, 8, 7, 6, 5. The transition from 11 to 10 in Counter x2 mode corresponds to the falling edge of tim_ti1 when the DIR bit is high.

Timing diagram for Directional clock encoder mode (CC1P = CC2P = 0) showing tim_ti1, tim_ti2, DIR bit, Counter x2 mode, and Counter x1 mode signals.

Figure 469. Directional clock encoder mode (CC1P = CC2P = 1)

Timing diagram for Directional clock encoder mode (CC1P = CC2P = 1). It shows four signals: tim_ti1, tim_ti2, DIR bit, and two counter modes (x2 and x1). tim_ti1 and tim_ti2 are square waves. The DIR bit is high when tim_ti1 is high and low when tim_ti1 is low. The Counter x2 mode shows a sequence of counts: 6, 7, 8, 9, 10, 11, 10, 9, 8, 7, 6, 5. The Counter x1 mode shows a sequence of counts: 7, 8, 9, 8, 7, 6. Vertical dashed lines align the transitions of tim_ti1 and tim_ti2 with the count changes in the counters.

MSv62354V1

Timing diagram for Directional clock encoder mode (CC1P = CC2P = 1). It shows four signals: tim_ti1, tim_ti2, DIR bit, and two counter modes (x2 and x1). tim_ti1 and tim_ti2 are square waves. The DIR bit is high when tim_ti1 is high and low when tim_ti1 is low. The Counter x2 mode shows a sequence of counts: 6, 7, 8, 9, 10, 11, 10, 9, 8, 7, 6, 5. The Counter x1 mode shows a sequence of counts: 7, 8, 9, 8, 7, 6. Vertical dashed lines align the transitions of tim_ti1 and tim_ti2 with the count changes in the counters.

Table 467 here-below details how the directional clock mode operates, for any input transition.

Table 467. Counting direction versus encoder signals and polarity settings

Directional clock modeSMS[3:0]Level on opposite signal
(tim_ti1fp1 for tim_ti2,
tim_ti2fp2 for tim_ti1)
tim_ti1fp1 signaltim_ti2fp2 signal
RisingFallingRisingFalling
x2 mode
CCxP = 0
1100HighDownDownUpUp
LowNo countNo countNo countNo count
x2 mode
CCxP = 1
1100HighNo countNo countNo countNo count
LowDownDownUpUp
x1 mode
CCxP = 0
1101HighNo countDownNo countUp
LowNo countNo countNo countNo count
x1 mode
CCxP = 1
1101HighNo countNo countNo countNo count
LowDownNo countUpNo count

Index input

The counter can be reset by an index signal coming from the encoder, indicating an absolute reference position. The index signal must be connected to the tim_etr_in input. It can be filtered using the digital input filter.

The index functionality is enabled with the IE bit in the TIMX_ECR register. The IE bit must be set only in encoder mode, when the SMS[3:0] bitfield has the following values: 0001, 0010, 011, 1010, 1011, 1100, 1101, 1110, 1111.

Available encoders are proposed with several options for index pulse conditioning, as per Figure 470:

Figure 470. Index gating options

Timing diagram for Figure 470 showing Channel A, Channel B, Gated A & B, Gated A, and Ungated signals. Channel A and B are square waves. Gated A & B is a narrow pulse aligned with both A and B edges. Gated A is a pulse aligned with A edges. Ungated is a pulse aligned with A edges but with a longer width.

MSv45765V1

Timing diagram for Figure 470 showing Channel A, Channel B, Gated A & B, Gated A, and Ungated signals. Channel A and B are square waves. Gated A & B is a narrow pulse aligned with both A and B edges. Gated A is a pulse aligned with A edges. Ungated is a pulse aligned with A edges but with a longer width.

The circuitry tolerates jitter on index signal, whatever the gating mode, as show on Figure 471.

In ungated mode, the signal must be strictly below two encoder periods. If the pulsewidth is greater or equal to two encoder period, the counter is reset multiple times.

Figure 471. Jittered Index signals

Timing diagram for Figure 471 showing Channel A, Channel B, Gated A & B, Gated A, and Ungated signals with jitter. The Ungated signal shows a long pulse with a hatched area indicating jitter. A horizontal arrow at the bottom indicates the 'Max pulsewidth ungated mode'.

MSv45766V1

Timing diagram for Figure 471 showing Channel A, Channel B, Gated A & B, Gated A, and Ungated signals with jitter. The Ungated signal shows a long pulse with a hatched area indicating jitter. A horizontal arrow at the bottom indicates the 'Max pulsewidth ungated mode'.

The timer supports the three gating options identically, without any specific programming needed. It is only necessary to define on which encoder state (for example channel A and

channel B state combination) the index must be synchronized, using the IPOS[1:0] bitfield in the TIMx_ECR register.

The index detection event acts differently depending on counting direction to ensure symmetrical operation during speed reversal:

This allows the index to be generated on the very same mechanical angular position whatever the counting direction. Figure 472 shows at which position is the index generated, for a simplistic example (an encoder providing four edges par mechanical rotation).

Figure 472. Index generation for IPOS[1:0] = 11

Figure 472. Index generation for IPOS[1:0] = 11

MSv45767V1

Figure 472. Index generation for IPOS[1:0] = 11

Figure 473 presents waveforms and corresponding values for IPOS[1:0] = 11. It shows that the instant at which the counter value is forced is automatically adjusted depending on the counting direction:

An interrupt can be issued upon index detection event.

The arrows are indicating on which transition is the index event interrupt generated.

Figure 473. Counter reading with index gated on channel A (IPOS[1:0] = 11)

Figure 473. Counter reading with index gated on channel A (IPOS[1:0] = 11)

MSv45768V1

Figure 473. Counter reading with index gated on channel A (IPOS[1:0] = 11)

Figure 474. presents waveforms and corresponding values for the ungated mode. The arrows are indicating on which transition is the index event generated.

Figure 474. Counter reading with index ungated (IPO[1:0] = 00)

Timing diagram for ungated index mode showing Channel A, Channel B, Index, DIR bit, and Counter waveforms.

The diagram shows the relationship between Channel A, Channel B, Index, DIR bit, and Counter in ungated mode. Channel A and B are square waves. The Index signal is a single pulse. The DIR bit is a logic level. The Counter is a 16-bit register. Arrows indicate the index event transitions. The counter values are shown in a sequence: 3, 4, 5, 6, 7, 0, 1, 2, 3, 4, 3, 2, 1, 0, 7, 6, 5, 4, 3, 2, 1, 0, 7. The label MSv45769V1 is at the bottom right.

Timing diagram for ungated index mode showing Channel A, Channel B, Index, DIR bit, and Counter waveforms.

Figure 475. shows how the 'gated on A & B' mode is handled, for various pulse alignment scenario. The arrows are indicating on which transition is the index event generated.

Figure 475. Counter reading with index gated on channel A and B

Timing diagram for gated index mode showing Channel A, Channel B, Index, DIR bit, and Counter waveforms.

The diagram shows the relationship between Channel A, Channel B, Index, DIR bit, and Counter in gated mode. Channel A and B are square waves. The Index signal is a single pulse. The DIR bit is a logic level. The Counter is a 16-bit register. Arrows indicate the index event transitions. The counter values are shown in a sequence: 5, 6, 7, 0, 1, 2, 3, 4, 5, 6, 5, 4, 3, 2, 1, 0, 7, 6, 5, 4, 3, 2, 1. The label MSv45770V1 is at the bottom right.

Timing diagram for gated index mode showing Channel A, Channel B, Index, DIR bit, and Counter waveforms.

Figure 476 and Figure 477 detail the case where the subsequent index pulse may be narrower than one quarter of the encoder clock period.

Figure 476. Encoder mode behavior in case of narrow index pulse (IPOS[1:0] = 11)

Timing diagrams for encoder mode behavior with narrow index pulse, showing Channel A, Channel B, Index, DIR bit, and Counter states for 'Index leading state transition' and 'Index delayed versus state transition'.

The figure consists of two separate timing diagrams, one above the other, illustrating encoder mode behavior with a narrow index pulse where IPOS[1:0] = 11. Both diagrams share the same set of signals: Channel A, Channel B, Index, DIR bit, and Counter.

Top Diagram: Index leading state transition

Bottom Diagram: Index delayed versus state transition

MSv45771V1

Timing diagrams for encoder mode behavior with narrow index pulse, showing Channel A, Channel B, Index, DIR bit, and Counter states for 'Index leading state transition' and 'Index delayed versus state transition'.

Figure 477. Counter reset Narrow index pulse (closer view, ARR = 0x07)

Timing diagram for counter reset narrow index pulse showing Channel A, Channel B, Index, DIR bit, and Counter signals across two cycles.

The diagram illustrates the timing relationship between Channel A, Channel B, Index, DIR bit, and Counter signals for a counter reset narrow index pulse. The counter is configured with ARR = 0x07.

The diagram is divided into two sections, each showing a sequence of counter cycles. The counter cycles are represented by a sequence of boxes labeled 5, 6, 7, 0, 1, 2, 3. The Index signal is a narrow pulse that occurs during cycle 7 and is reset to 0 during cycle 0. The DIR bit is a constant low signal. Channel A and Channel B are square waves that are synchronized with the counter cycles.

The top section shows the counter cycles 5, 6, 7, 0, 1, 2, 3. The Index signal is a narrow pulse that occurs during cycle 7 and is reset to 0 during cycle 0. The DIR bit is a constant low signal. Channel A and Channel B are square waves that are synchronized with the counter cycles.

The bottom section shows the counter cycles 4, 5, 6, 7, 0, 1, 2, 3. The Index signal is a narrow pulse that occurs during cycle 7 and is reset to 0 during cycle 0. The DIR bit is a constant low signal. Channel A and Channel B are square waves that are synchronized with the counter cycles.

MSv45772V1

Timing diagram for counter reset narrow index pulse showing Channel A, Channel B, Index, DIR bit, and Counter signals across two cycles.

Figure 478 shows how the index is managed in x1 and x2 modes.

Timing diagram for Figure 478 showing Channel A, Channel B, Index, DIR bit, Counter x2, and Counter x1 signals. The diagram illustrates the index behavior in x1 and x2 modes when IPOS[1:0] = 01. Channel A and B are square waves. The Index signal is a pulse. The DIR bit is a control signal. Counter x2 and x1 show the counting sequence with index resets.

Figure 478. Index behavior in x1 and x2 mode (IPOS[1:0] = 01)

The diagram shows the following signals and their behavior:

MSv45773V1

Timing diagram for Figure 478 showing Channel A, Channel B, Index, DIR bit, Counter x2, and Counter x1 signals. The diagram illustrates the index behavior in x1 and x2 modes when IPOS[1:0] = 01. Channel A and B are square waves. The Index signal is a pulse. The DIR bit is a control signal. Counter x2 and x1 show the counting sequence with index resets.

Directional index sensitivity

The IDIR[1:0] bitfield in the TIMx_ECR register allows the index to be active only in a selected counting direction.

Figure 479 shows the relationship between index and counter reset events, depending on IDIR[1:0] value.

Timing diagram for Figure 479 showing DIR bit, Counter, Index input, and Counter reset signals for different IDIR[1:0] values. The diagram illustrates the relationship between index and counter reset events depending on the IDIR[1:0] value.

Figure 479. Directional index sensitivity

The diagram shows the following signals and their behavior:

MSv45774V1

Timing diagram for Figure 479 showing DIR bit, Counter, Index input, and Counter reset signals for different IDIR[1:0] values. The diagram illustrates the relationship between index and counter reset events depending on the IDIR[1:0] value.

Special first index event management

The FIDX bit in the TIMx_ECR register allows the index to be taken only once, as shown on Figure 480. Once the first index has arrived, any subsequent index is ignored. If needed, the circuitry can be rearmed by writing the FIDX bit to 0 and setting it again to 1.

Figure 480. Counter reset as function of FIDX bit setting

Timing diagram for Figure 480 showing Counter, Index input, and Counter reset for FIDX = 0 and FIDX = 1.

The diagram illustrates the counter reset behavior based on the FIDX bit setting. It consists of four horizontal signal traces:

MSv45775V1

Timing diagram for Figure 480 showing Counter, Index input, and Counter reset for FIDX = 0 and FIDX = 1.

Index blanking

The index event can be blanked using the tim_ti3 or tim_ti4 inputs. During the blanking window, the index events are no longer resetting the counter, as shown on the Figure 481 below.

This mode is enabled using the IBLK[1:0] bitfield in the TIMx_ECR register, as following:

Figure 481. Index blanking

Timing diagram for Figure 481 showing Counter, Index input, Blanking signal TI3 (CC3P=0), and Counter reset for IBLK[1:0] = 00 and IBLK[1:0] = 01.

The diagram illustrates index blanking behavior. It consists of five horizontal signal traces:

MSv45776V1

Timing diagram for Figure 481 showing Counter, Index input, Blanking signal TI3 (CC3P=0), and Counter reset for IBLK[1:0] = 00 and IBLK[1:0] = 01.

Index management in nonquadrature mode

Figure 482 and Figure 483 detail how the index is managed in directional clock mode and clock plus direction mode, when the SMS[3:0] bitfield is equal to 1010, 1011, 1100, 1101.

For both of these modes, the index sensitivity is set with the IPOS[0] bit as following:

The IPOS[1] bit is not-significant.

Figure 482. Index behavior in clock + direction mode, IPOS[0] = 1

Figure 482. Index behavior in clock + direction mode, IPOS[0] = 1. Waveforms for tim_ti1, tim_ti2, Index, Counter x2 mode (values: 7, 0, 1, 2, 3, 4, 3, 2, 7, 6, 5), and Counter x1 mode (values: 7, 0, 1, 2, 1, 7).

MSv62355V1

Figure 482. Index behavior in clock + direction mode, IPOS[0] = 1. Waveforms for tim_ti1, tim_ti2, Index, Counter x2 mode (values: 7, 0, 1, 2, 3, 4, 3, 2, 7, 6, 5), and Counter x1 mode (values: 7, 0, 1, 2, 1, 7).

Figure 483. Index behavior in directional clock mode, IPOS[0] = 1

Figure 483. Index behavior in directional clock mode, IPOS[0] = 1. Waveforms for tim_ti1, tim_ti2, DIR bit, Counter x2 mode (values: 9, 0, 1, 2, 3, 4, 3, 2, 1, 0, 9, 8), and Counter x1 mode (values: 9, 0, 1, 2, 1, 0, 9).

MSv62356V1

Figure 483. Index behavior in directional clock mode, IPOS[0] = 1. Waveforms for tim_ti1, tim_ti2, DIR bit, Counter x2 mode (values: 9, 0, 1, 2, 3, 4, 3, 2, 1, 0, 9, 8), and Counter x1 mode (values: 9, 0, 1, 2, 1, 0, 9).

Encoder error management

For encoder configurations where two quadrature signals are available, it is possible to detect transition errors. The reading on the two inputs corresponds to a 2-bit gray code which can be represented as a state diagram, on Figure 484.. A single bit is expected to change at once. An erroneous transition sets the TERRF interrupt flag in the TIMx_SR

status register. A transition error interrupt is generated if the TERRIE bit is set in the TIMx_DIER register.

Figure 484. State diagram for quadrature encoded signals

State diagram for quadrature encoded signals showing four states (00, 01, 10, 11) and their transitions.

The diagram shows four states represented by circles labeled 00, 01, 10, and 11. Correct transitions are indicated by solid double-headed arrows between adjacent states: 00 ↔ 01, 01 ↔ 11, 11 ↔ 10, and 10 ↔ 00. Erroneous transitions are indicated by dashed double-headed arrows between diagonal states: 00 ↔ 11 and 01 ↔ 10. A legend at the bottom left shows a solid double-headed arrow for 'Correct transitions' and a dashed double-headed arrow for 'Erroneous transitions'. The reference code MSv45779V1 is located at the bottom right.

State diagram for quadrature encoded signals showing four states (00, 01, 10, 11) and their transitions.

For encoder having an index signal, it is possible to detect abnormal operation resulting in an excess of pulses per revolution. An encoder with N pulses per revolution provides 4xN counts per revolution. The index signal resets the counter every 4xN clock periods.

If the counter value is incremented from TIMx_ARR to 0 or decremented from 0 to TIMxARR value without any index event, this is reported as an index position error.

The overflow threshold is programmed using the TIMx_ARR register. A 1000 lines encoder results in a counter value being between 0 and 3999 (in 4x reading mode). The overflow detection threshold must be programmed by setting TIMx_ARR = 3999+1 = 4000.

The error assertion is delayed to the transition 0 to 1 when in up-counting. This is cope with narrow index pulses in gated A and B mode, as shown on Figure 485.

Figure 485. Up-counting encoder error detection

Timing diagram showing up-counting encoder error detection in two scenarios. The top scenario shows an 'Abort (index detection)' occurring at the transition from counter value 7 to 0. The bottom scenario shows an 'Error detected' at the transition from 7 to 0 and an 'Error asserted' at the transition from 0 to 1. Both scenarios involve signals for tim_ti1, tim_ti2, Index, IERRF, and a Counter.

The figure consists of two separate timing diagrams, one above the other, illustrating encoder error detection during up-counting. Both diagrams share the same set of signals: tim_ti1, tim_ti2, Index, IERRF, and a Counter.

Top Diagram: The counter sequence is 5, 6, 7, 0, 1, 2, 3. tim_ti1 is high from the start of counter 7 to the start of counter 1. tim_ti2 is high from the start of counter 5 to the start of counter 1. The Index signal has a narrow high pulse that occurs during the transition from counter 7 to counter 0. An arrow labeled "Error detected" points to this transition. Another arrow labeled "Abort (index detection)" points to the start of counter 0.

Bottom Diagram: The counter sequence is 5, 6, 7, 0, 1, 2, 3. tim_ti1 and tim_ti2 have the same timing as in the top diagram. The Index signal has a narrow high pulse that occurs during the transition from counter 0 to counter 1. An arrow labeled "Error detected" points to the transition from counter 7 to counter 0. Another arrow labeled "Error asserted" points to the transition from counter 0 to counter 1. The IERRF signal transitions from low to high at the start of counter 1.

MSv62357V1

Timing diagram showing up-counting encoder error detection in two scenarios. The top scenario shows an 'Abort (index detection)' occurring at the transition from counter value 7 to 0. The bottom scenario shows an 'Error detected' at the transition from 7 to 0 and an 'Error asserted' at the transition from 0 to 1. Both scenarios involve signals for tim_ti1, tim_ti2, Index, IERRF, and a Counter.

In down-counting mode, the detection is conditioned by a preliminary transition from 1 to 0. This is to cope with narrow index pulses in gated A and B mode, as shown on Figure 486, to avoid any false error detection in case the encoder dithers between TIMx_ARR and 0 immediately after the index detection.

Figure 486. Down-counting encode error detection

Figure 486. Down-counting encode error detection timing diagram.

Timing diagram illustrating down-counting encode error detection with signals: tim_ti1, tim_ti2, Index, IERRF, and Counter value sequences.
Top section (No error): Counter counts down 2, 1, 0, then wraps to 7 (TIMx_ARR) following an index pulse without triggering IERRF. Another transition from 0 to 7 without index (not following 1 to 0 transition) also asserts no error.
Bottom section (Error detected/asserted): Counter counts 2, 1, 0, wraps to 7 where error is detected, and IERRF goes high (error asserted) on subsequent counter decrements to 6, 5, 4.

Figure 486. Down-counting encode error detection timing diagram.

An index error sets the IERRF interrupt flag in the TIMx_SR status register. An index error interrupt is generated if the IERRIE bit is set in the TIMx_DIER register.

Functional encoder interrupts

The following interrupts are also available in encoder mode

Slave mode selection preload for run-time encoder mode update

It may be necessary to switch from one encoder mode to another during run-time. This is typically done at high-speed to decrease the update interrupt rate, by switching from x4 to x2 to x1 mode, as shown on Figure 487.

For this purpose, the SMS[3:0] bit can be preloaded. This is enabled by setting the SMSPE enable bit in the TIMx_SMCR register. The trigger for the transfer from SMS[3:0] preload to active value can be selected with the SMSPS bit in the TIMx_SMCR register.

Figure 487. Encoder mode change with preload transferred on update (SMSPS = 0)

Timing diagram showing encoder mode change with preload transferred on update (SMSPS = 0). The diagram illustrates the transition from x4 mode to x2 mode to x1 mode. It shows the Update event, Preload value, and Active value for the SMS register. The Preload value is set to SMS = 0011 for x4 mode, SMS = 0001 for x2 mode, and SMS = 1110 for x1 mode. The Active value is updated to the Preload value upon an Update event. The diagram is labeled MSv45781V1.

The diagram illustrates the encoder mode change process. It shows three modes: x4 mode, x2 mode, and x1 mode. The Update event is shown as a series of pulses. The Preload value is set to SMS = 0011 for x4 mode, SMS = 0001 for x2 mode, and SMS = 1110 for x1 mode. The Active value is updated to the Preload value upon an Update event. The diagram is labeled MSv45781V1.

Timing diagram showing encoder mode change with preload transferred on update (SMSPS = 0). The diagram illustrates the transition from x4 mode to x2 mode to x1 mode. It shows the Update event, Preload value, and Active value for the SMS register. The Preload value is set to SMS = 0011 for x4 mode, SMS = 0001 for x2 mode, and SMS = 1110 for x1 mode. The Active value is updated to the Preload value upon an Update event. The diagram is labeled MSv45781V1.

Encoder clock output

The encoder mode operating principle is not perfectly suited for high-resolution velocity measurements, at low speed, as it requires a relatively long integration time to have a sufficient number of clock edges and a precise measurement.

At low speed, a better solution is to do an edge-to-edge clock period measurement. This can be achieved using a slave timer. The timer can output the encoder clock information on the tim_trgo output. The slave timer can then perform a period measurement and provide velocity information for each and every encoder clock edge.

This mode is enabled by setting the MMS[3:0] bitfield to 1000, in the TIMx_CR2 register. It is valid for the following SMS[3:0] values: 0001, 0010, 0011, 1010, 1011, 1100, 1101, 1110, 1111. Any other SMS[3:0] code is not allowed and may lead to unexpected behavior.

43.3.26 Direction bit output

It is possible to output a direction signal out of the timer, on the tim_oc3n and tim_oc4 output signals (copy of the DIR bit in the TIMx_CR1 register). This is achieved by setting the OC3M[3:0] or the OC4M[3:0] bitfield to 1011 in the TIMx_CCMR2 register.

This feature can be used for monitoring the counting direction (or rotation direction) in encoder mode, or to have a signal indicating the up/down phases in center-aligned PWM mode.

43.3.27 UIF bit remapping

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This allows both the counter value and a potential roll-over condition signaled by the UIFCPY flag to be read in an atomic way. In particular cases, it can ease the calculations by avoiding race conditions, caused for instance by a processing shared between a background task (counter reading) and an interrupt (update interrupt).

There is no latency between the UIF and UIFCPY flags assertion.

43.3.28 Timer input XOR function

The TI1S bit in the TIMx_CR2 register, allows the input filter of channel 1 to be connected to the output of an XOR gate, combining the three input pins tim_ti1, tim_ti2 and tim_ti3.

The XOR output can be used with all the timer input functions such as trigger or input capture. It is convenient to measure the interval between edges on two input signals, as per Figure 488.

Figure 488. Measuring time interval between edges on three signals

Timing diagram showing three input signals (tim_ti1, tim_ti2, tim_ti3), their XOR combination, and the resulting TIMx Counter increments at each transition.
Timing diagram showing three input signals (tim_ti1, tim_ti2, tim_ti3), their XOR combination, and the resulting TIMx Counter increments at each transition.

43.3.29 Interfacing with Hall sensors

This is done using the advanced-control timers to generate PWM signals to drive the motor and another timer TIMx referred to as “interfacing timer” in Figure 489. The “interfacing timer” captures the three timer input pins (tim_ti1, tim_ti2 and tim_ti3) connected through a XOR to the tim_ti1 input channel (selected by setting the TI1S bit in the TIMx_CR2 register).

The slave mode controller is configured in reset mode; the slave input is tim_ti1f_ed. Thus, each time one of the three inputs toggles, the counter restarts counting from 0. This creates a time base triggered by any change on the Hall inputs.

On the “interfacing timer”, capture/compare channel 1 is configured in capture mode, capture signal is tim_trc (See Figure 431). The captured value, which corresponds to the time elapsed between two changes on the inputs, gives information about motor speed.

The “interfacing timer” can be used in output mode to generate a pulse which changes the configuration of the channels of the advanced-control timer (by triggering a COM event). The advanced-control timer is used to generate PWM signals to drive the motor. To do this, the interfacing timer channel must be programmed so that a positive pulse is generated after a programmed delay (in output compare or PWM mode). This pulse is sent to the advanced-control timer through the tim_trgo output.

In this example the user wants to change the PWM configuration of the advanced-control timer after a programmed delay each time a change occurs on the Hall inputs connected to one of the TIMx timers.

In the advanced-control timer, the right tim_itrx input must be selected as trigger input, the timer is programmed to generate PWM signals, the capture/compare control signals are preloaded (CCPC = 1 in the TIMx_CR2 register) and the COM event is controlled by the trigger input (CCUS = 1 in the TIMx_CR2 register). The PWM control bits (CCxE, OCxM) are written after a COM event for the next step (this can be done in an interrupt subroutine generated by the rising edge of tim_oc2ref).

Figure 489 describes this example.

Figure 489. Example of Hall sensor interface

Timing diagram for a Hall sensor interface showing signals for an interfacing timer and advanced-control timers.

The diagram illustrates the timing relationship between an interfacing timer and advanced-control timers in a Hall sensor interface. It is divided into two main sections: 'Interfacing timer' and 'Advanced-control timers'.

Interfacing timer signals:

Advanced-control timers signals:

Vertical dashed lines indicate the timing of events across all signals. At the bottom, eight arrows point upwards to these lines, with the text "Write CCxE, CCxNE and OCxM for next step" indicating the configuration actions required at these points. The reference ID "MSv62360V1" is located in the bottom right corner of the diagram area.

Timing diagram for a Hall sensor interface showing signals for an interfacing timer and advanced-control timers.

43.3.30 Timer synchronization

The TIMx timers are linked together internally for timer synchronization or chaining. Refer to Section 44.4.23: Timer synchronization for details. They can be synchronized in several modes: Reset mode, Gated mode, Trigger mode, Reset + trigger, and gated + reset modes.

Slave mode: Reset mode

The counter and its prescaler can be reinitialized in response to an event on a trigger input. Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated.

In the following example, the upcounter is cleared in response to a rising edge on tim_ti1 input:

The counter starts counting on the internal clock, then behaves normally until tim_ti1 rising edge. When tim_ti1 rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request, or a DMA request can be sent if enabled (depending on the TIE and TDE bits in TIMx_DIER register).

The following figure shows this behavior when the autoreload register TIMx_ARR = 0x36. The delay between the rising edge on tim_ti1 and the actual reset of the counter is due to the resynchronization circuit on tim_ti1 input.

Figure 490. Control circuit in reset mode

Timing diagram for Figure 490: Control circuit in reset mode. The diagram shows five signals over time: 1. tim_ti1: A square wave input signal. 2. Counter reset and update: A pulse that occurs on the rising edge of tim_ti1. 3. tim_cnt_ck, tim_psc_ck: A periodic clock signal. 4. Counter register: A sequence of values 30, 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 00, 01, 02, 03. The counter increments on each clock pulse until it reaches 36, then resets to 00. A rising edge on tim_ti1 occurs while the counter is at 02, causing it to reset to 00. 5. TIF: A pulse that occurs on the rising edge of tim_ti1. Vertical dashed lines indicate the timing of the tim_ti1 rising edge and the counter reset/update pulse. The counter register values are shown in boxes, with the first seven values (30-36) occurring before the reset and the next seven (00-03) occurring after the reset.

MSv62361V1

Timing diagram for Figure 490: Control circuit in reset mode. The diagram shows five signals over time: 1. tim_ti1: A square wave input signal. 2. Counter reset and update: A pulse that occurs on the rising edge of tim_ti1. 3. tim_cnt_ck, tim_psc_ck: A periodic clock signal. 4. Counter register: A sequence of values 30, 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 00, 01, 02, 03. The counter increments on each clock pulse until it reaches 36, then resets to 00. A rising edge on tim_ti1 occurs while the counter is at 02, causing it to reset to 00. 5. TIF: A pulse that occurs on the rising edge of tim_ti1. Vertical dashed lines indicate the timing of the tim_ti1 rising edge and the counter reset/update pulse. The counter register values are shown in boxes, with the first seven values (30-36) occurring before the reset and the next seven (00-03) occurring after the reset.

Slave mode: Gated mode

The counter can be enabled depending on the level of a selected input.

In the following example, the upcounter counts only when tim_ti1 input is low:

The counter starts counting on the internal clock as long as tim_ti1 is low and stops as soon as tim_ti1 becomes high. The TIF flag in the TIMx_SR register is set both when the counter starts or stops.

The delay between the rising edge on tim_ti1 and the actual stop of the counter is due to the resynchronization circuit on tim_ti1 input.

Figure 491. Control circuit in Gated mode

Timing diagram for Gated mode showing the relationship between tim_ti1, Counter enable, tim_cnt_ck, tim_psc_ck, Counter register, and TIF.

The diagram illustrates the control circuit in Gated mode. It shows the following signals over time:

MSv62362V1

Timing diagram for Gated mode showing the relationship between tim_ti1, Counter enable, tim_cnt_ck, tim_psc_ck, Counter register, and TIF.

Slave mode: Trigger mode

The counter can start in response to an event on a selected input.

In the following example, the upcounter starts in response to a rising edge on tim_ti2 input:

When a rising edge occurs on tim_ti2, the counter starts counting on the internal clock and the TIF flag is set.

The delay between the rising edge on tim_ti2 and the actual start of the counter is due to the resynchronization circuit on tim_ti2 input.

Figure 492. Control circuit in trigger mode

Timing diagram for Figure 492: Control circuit in trigger mode. The diagram shows five signals over time: tim_ti2, Counter enable, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. A vertical dashed line marks a trigger event. tim_ti2 is high before the event, goes low during the event, and returns high. Counter enable is high before the event, goes low during the event, and returns high. tim_cnt_ck and tim_psc_ck are high-frequency square waves. Counter register shows a value of 34 before the event, and then values 35, 36, 37, and 38 after the event. TIF is low before the event and goes high after the event.

MSv62363V1

Timing diagram for Figure 492: Control circuit in trigger mode. The diagram shows five signals over time: tim_ti2, Counter enable, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. A vertical dashed line marks a trigger event. tim_ti2 is high before the event, goes low during the event, and returns high. Counter enable is high before the event, goes low during the event, and returns high. tim_cnt_ck and tim_psc_ck are high-frequency square waves. Counter register shows a value of 34 before the event, and then values 35, 36, 37, and 38 after the event. TIF is low before the event and goes high after the event.

Slave mode: Combined reset + trigger mode

In this case, a rising edge of the selected trigger input (tim_trgi) reinitializes the counter, generates an update of the registers, and starts the counter.

This mode is used for One-pulse mode.

Slave mode: Combined gated + reset mode

The counter clock is enabled when the trigger input (tim_trgi) is high. The counter stops and is reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.

This mode is used to detect out-of-range PWM signal (duty cycle exceeding a maximum expected value).

Slave mode: external clock mode 2 + trigger mode

The external clock mode 2 can be used in addition to another slave mode (except external clock mode 1 and encoder mode). In this case, the tim_etr_in signal is used as external clock input, and another input can be selected as trigger input (in reset mode, gated mode or trigger mode). It is recommended not to select tim_etr_in as tim_trgi through the TS bits of TIMx_SMCR register.

In the following example, the upcounter is incremented at each rising edge of the tim_etr_in signal as soon as a rising edge of tim_ti1 occurs:

  1. 1. Configure the external trigger input circuit by programming the TIMx_SMCR register as follows:
    • – ETF = 0000: no filter
    • – ETPS = 00: prescaler disabled
    • – ETP = 0: detection of rising edges on tim_etr_in and ECE = 1 to enable the external clock mode 2.
  2. 2. Configure the channel 1 as follows, to detect rising edges on TI:
    • – IC1F = 0000: no filter.
    • – The capture prescaler is not used for triggering and does not need to be configured.
    • – CC1S = 01 in TIMx_CCMR1 register to select only the input capture source
    • – CC1P = 0 and CC1NP = 0 in TIMx_CCER register to validate the polarity (and detect rising edge only).
  3. 3. Configure the timer in trigger mode by writing SMS = 110 in TIMx_SMCR register. Select tim_ti1 as the input source by writing TS = 00101 in TIMx_SMCR register.

A rising edge on tim_ti1 enables the counter and sets the TIF flag. The counter then counts on tim_etr_in rising edges.

The delay between the rising edge of the tim_etr_in signal and the actual reset of the counter is due to the resynchronization circuit on tim_etrp input.

Figure 493. Control circuit in external clock mode 2 + trigger mode

Timing diagram for Figure 493 showing the control circuit in external clock mode 2 + trigger mode. The diagram includes six signals: tim_ti1, Counter enable, ETR, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. tim_ti1 is a single-pulse trigger. Counter enable is high when tim_ti1 is high. ETR is a periodic square wave. tim_cnt_ck and tim_psc_ck are clock signals that are active when Counter enable is high. The Counter register shows values 34, 35, and 36, indicating it increments on each rising edge of ETR. TIF is a flag that is high when tim_ti1 is high.

The diagram illustrates the timing relationship between various signals in external clock mode 2 + trigger mode. tim_ti1 is a trigger signal that enables the counter. Counter enable is high when tim_ti1 is high. ETR is a periodic square wave. tim_cnt_ck and tim_psc_ck are clock signals that are active when Counter enable is high. The Counter register shows values 34, 35, and 36, indicating it increments on each rising edge of ETR. TIF is a flag that is high when tim_ti1 is high.

Timing diagram for Figure 493 showing the control circuit in external clock mode 2 + trigger mode. The diagram includes six signals: tim_ti1, Counter enable, ETR, tim_cnt_ck, tim_psc_ck, Counter register, and TIF. tim_ti1 is a single-pulse trigger. Counter enable is high when tim_ti1 is high. ETR is a periodic square wave. tim_cnt_ck and tim_psc_ck are clock signals that are active when Counter enable is high. The Counter register shows values 34, 35, and 36, indicating it increments on each rising edge of ETR. TIF is a flag that is high when tim_ti1 is high.

Note: The clock of the slave peripherals (such as timer, ADC) receiving the tim_trgo or the tim_trgo2 signals must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

43.3.31 ADC triggers

The timer can generate an ADC triggering event with various internal signals, such as reset, enable or compare events. It is also possible to generate a pulse issued by internal edge detectors, such as:

The triggers are issued on the tim_trgo2 internal line which is redirected to the ADC. There is a total of 16 possible events, which can be selected using the MMS2[3:0] bits in the TIMx_CR2 register.

An example of an application for 3-phase motor drives is given in Figure 446.

Note: The clock of the slave peripherals (timer, ADC, ...) receiving the tim_trgo or the tim_trgo2 signals must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

The clock of the ADC must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the timer.

43.3.32 DMA burst mode

The TIMx timers have the capability to generate multiple DMA requests upon a single event. The main purpose is to be able to reprogram part of the timer multiple times without software overhead, but it can also be used to read several registers in a row, at regular intervals.

The DMA controller destination is unique and must point to the virtual register TIMx_DMAR. On a given timer event, the timer launches a sequence of DMA requests (burst). Each write into the TIMx_DMAR register is actually redirected to one of the timer registers.

The DBL[4:0] bits in the TIMx_DCR register set the DMA burst length. The timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address, i.e. the number of transfers (either in half-words or in bytes).

The DBA[4:0] bits in the TIMx_DCR register define the DMA base address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register:

Example:

00000: TIMx_CR1

00001: TIMx_CR2

00010: TIMx_SMCR

The DBSS[3:0] bits in the TIMx_DCR register defines the interrupt source that triggers the DMA burst transfers (see Section 43.6.29: TIMx DMA control register (TIMx_DCR)(x = 1, 8) for details).

As an example, the timer DMA burst feature is used to update the contents of the CCRx registers (x = 2,3,4) upon an update event, with the DMA transferring half words into the CCRx registers.

This is done in the following steps:

  1. 1. Configure the corresponding DMA channel as follows:
    • – DMA channel peripheral address is the DMAR register address.
    • – DMA channel memory address is the address of the buffer in the RAM containing the data to be transferred by DMA into CCRx registers.
    • – Number of data to transfer = 3 (see note below).
    • – Circular mode disabled.
  2. 2. Configure the DCR register by configuring the DBA and DBL bitfields as follows:
    DBL = 3 transfers, DBA = 0xE and DBSS = 1.
  3. 3. Enable the TIMx update DMA request (set the UDE bit in the DIER register).
  4. 4. Enable TIMx.
  5. 5. Enable the DMA channel.

This example is for the case where every CCRx register to be updated once. If every CCRx register is to be updated twice for example, the number of data to transfer must be 6. Let's take the example of a buffer in the RAM containing data1, data2, data3, data4, data5, and data6. The data is transferred to the CCRx registers as follows: on the first update DMA request, data1 is transferred to CCR2, data2 is transferred to CCR3, data3 is transferred to CCR4 and on the second update DMA request, data4 is transferred to CCR2, data5 is transferred to CCR3, and data6 is transferred to CCR4.

Note: A null value can be written to the reserved registers.

43.3.33 TIM1/TIM8 DMA requests

The TIM1/TIM8 can generate a DMA request, as shown in the table below.

Table 468. DMA request

DMA request signalDMA requestEnable control bit
tim_upd_dmaUpdateUDE
tim_cc1_dmaCapture/compare 1CC1DE
tim_cc2_dmaCapture/compare 2CC2DE
tim_cc3_dmaCapture/compare 3CC3DE
tim_cc4_dmaCapture/compare 4CC4DE
tim_com_dmaCommutation (COM)COMDE
tim_trgi_dmaTriggerTDE

43.3.34 Debug mode

When the microcontroller enters debug mode (Cortex-M33 core halted), the TIMx counter can either continue to work normally or stop, depending on DBG_TIMx_STOP configuration bit in DBG module.

The behavior in debug mode can be programmed with a dedicated configuration bit per timer in the Debug support (DBG) module.

For safety purposes, when the counter is stopped, the outputs are disabled (as if the MOE bit was reset). The outputs can either be forced to an inactive state (OSSI bit = 1), or have their control taken over by the GPIO controller (OSSI bit = 0), typically to force a Hi-Z.

For more details, refer to section Debug support (DBG).

43.4 TIM1/TIM8 low-power modes

Table 469. Effect of low-power modes on TIM1/TIM8

ModeDescription
SleepNo effect, peripheral is active. The interrupts can cause the device to exit from Sleep mode.
StopThe timer operation is stopped and the register content is kept. No interrupt can be generated.
StandbyThe timer is powered-down and must be reinitialized after exiting the Standby mode.

43.5 TIM1/TIM8 interrupts

The TIM1/TIM8 can generate multiple interrupts, as shown in Table 470.

Table 470. Interrupt requests

Interrupt acronymInterrupt eventEvent flagEnable control bitInterrupt clear methodExit from Sleep modeExit from Stop and Standby mode
TIM_UPDUpdateUIFUIEwrite 0 in UIFYesNo
TIM_CCCapture/compare 1CC1IFCC1IEwrite 0 in CC1IFYesNo
Capture/compare 2CC2IFCC2IEwrite 0 in CC2IFYesNo
Capture/compare 3CC3IFCC3IEwrite 0 in CC3IFYesNo
Capture/compare 4CC4IFCC4IEwrite 0 in CC4IFYesNo
TIM_TRGI_COM_DIR_IDXTIM_COMCommutation (COM)COMIFCOMIEwrite 0 in COMIFYesNo
TIM_TRGITriggerTIFTIEwrite 0 in TIFYesNo
TIM_IDXIndexIDXFIDXIEwrite 0 in IDXFYesNo
TIM_DIRDirectionDIRFDIRIEwrite 0 in DIRFYesNo
TIM_BRK_TERR_IERRTIM_BRKBreakBIFBIEwrite 0 in BIFYesNo
Break2B2IFwrite 0 in B2IFYesNo
System BreakSBIFwrite 0 in SBIFYesNo
TIM_IERRIndex ErrorIERRFIERRIEwrite 0 in IERRFYesNo
TIM_TERRTransition ErrorTERRFTERRIEwrite 0 in TERRFYesNo

43.6 TIM1/TIM8 registers

Refer to Section 1.2 for a list of abbreviations used in register descriptions.

The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).

43.6.1 TIMx control register 1 (TIMx_CR1)(x = 1, 8)

Address offset: 0x000

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.DITH
EN
UIFRE
MAP
Res.CKD[1:0]ARPECMS[1:0]DIROPMURSUDISCEN
rwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:13 Reserved, must be kept at reset value.

Bit 12 DITHEN: Dithering enable

0: Dithering disabled

1: Dithering enabled

Note: The DITHEN bit can only be modified when CEN bit is reset.

Bit 11 UIFREMAP: UIF status bit remapping

0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.

1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.

Bit 10 Reserved, must be kept at reset value.

Bits 9:8 CKD[1:0]: Clock division

This bitfield indicates the division ratio between the timer clock (tim_ker_ck) frequency and the dead-time and sampling clock (tDTS) used by the dead-time generators and the digital filters (tim_etr_in, tim_tix),

00: tDTS = ttim_ker_ck

01: tDTS = 2*ttim_ker_ck

10: tDTS = 4*ttim_ker_ck

11: Reserved, do not program this value

Bit 7 ARPE: Autoreload preload enable

0: TIMx_ARR register is not buffered

1: TIMx_ARR register is buffered

Bits 6:5 CMS[1:0]: Center-aligned mode selection

00: Edge-aligned mode. The counter counts up or down depending on the direction bit (DIR).

01: Center-aligned mode 1. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS = 00 in TIMx_CCMRx register) are set only when the counter is counting down.

10: Center-aligned mode 2. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS = 00 in TIMx_CCMRx register) are set only when the counter is counting up.

11: Center-aligned mode 3. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS = 00 in TIMx_CCMRx register) are set both when the counter is counting up or down.

Note: It is not allowed to switch from edge-aligned mode to center-aligned mode as long as the counter is enabled (CEN = 1)

Bit 4 DIR: Direction

Note: This bit is read only when the timer is configured in Center-aligned mode or Encoder mode.

Bit 3 OPM: One-pulse mode

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

These events can be:

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

Buffered registers are then loaded with their preload values.

Bit 0 CEN: Counter enable

Note: External clock, gated mode and encoder mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

43.6.2 TIMx control register 2 (TIMx_CR2)(x = 1, 8)

Address offset: 0x004

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.MMS[3]Res.MMS2[3:0]Res.OIS6Res.OIS5
rwrwrwrwrwrwrw
1514131211109876543210
OIS4NOIS4OIS3NOIS3OIS2NOIS2OIS1NOIS1TI1SMMS[2:0]CCDSCCUSRes.CCPC
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:26 Reserved, must be kept at reset value.

Bit 24 Reserved, must be kept at reset value.

Bits 23:20 MMS2[3:0]: Master mode selection 2

These bits allow the information to be sent to ADC for synchronization (tim_trgo2) to be selected. The combination is as follows:

0000: Reset - the UG bit from the TIMx_EGR register is used as trigger output (tim_trgo2). If the reset is generated by the trigger input (slave mode controller configured in reset mode), the signal on tim_trgo2 is delayed compared to the actual reset.

0001: Enable - the Counter Enable signal CNT_EN is used as trigger output (tim_trgo2). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated by a logic AND between the CEN control bit and the trigger input when configured in Gated mode. When the Counter Enable signal is controlled by the trigger input, there is a delay on tim_trgo2, except if the Master/Slave mode is selected (see the MSM bit description in TIMx_SMCR register).

0010: Update - the update event is selected as trigger output (tim_trgo2). For instance, a master timer can then be used as a prescaler for a slave timer.

0011: Compare pulse - the trigger output sends a positive pulse when the CC1IF flag is to be set (even if it was already high), as soon as a capture or compare match occurs (tim_trgo2).

0100: Compare - tim_oc1refc signal is used as trigger output (tim_trgo2)

0101: Compare - tim_oc2refc signal is used as trigger output (tim_trgo2)

0110: Compare - tim_oc3refc signal is used as trigger output (tim_trgo2)

0111: Compare - tim_oc4refc signal is used as trigger output (tim_trgo2)

1000: Compare - tim_oc5refc signal is used as trigger output (tim_trgo2)

1001: Compare - tim_oc6refc signal is used as trigger output (tim_trgo2)

1010: Compare Pulse - tim_oc4refc rising or falling edges generate pulses on tim_trgo2

1011: Compare pulse - tim_oc6refc rising or falling edges generate pulses on tim_trgo2

1100: Compare pulse - tim_oc4refc or tim_oc6refc rising edges generate pulses on tim_trgo2

1101: Compare pulse - tim_oc4refc rising or tim_oc6refc falling edges generate pulses on tim_trgo2

1110: Compare pulse - tim_oc5refc or tim_oc6refc rising edges generate pulses on tim_trgo2

1111: Compare pulse - tim_oc5refc rising or tim_oc6refc falling edges generate pulses on tim_trgo2

Note: The clock of the slave timer or ADC must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Bit 19 Reserved, must be kept at reset value.

Bit 18 OIS6: Output idle state 6 (tim_oc6 output)

Refer to OIS1 bit

Bit 17 Reserved, must be kept at reset value.

Bit 16 OIS5: Output idle state 5 (tim_oc5 output)

Refer to OIS1 bit

Bit 15 OIS4N: Output idle state 4 (tim_oc4n output)

Refer to OIS1N bit

Bit 14 OIS4: Output idle state 4 (tim_oc4 output)

Refer to OIS1 bit

Bits 25, 6:4 MMS[3:0]: Master mode selection

These bits select the information to be sent in master mode to slave timers for synchronization (tim_trgo). The combination is as follows:

Other codes reserved

Note: The clock of the slave timer or ADC must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Bit 3 CCDS: Capture/compare DMA selection

Bit 2 CCUS: Capture/compare control update selection

Note: This bit acts only on channels that have a complementary output.

Bit 1 Reserved, must be kept at reset value.

Bit 0 CCPC: Capture/compare preloaded control

Note: This bit acts only on channels that have a complementary output.

43.6.3 TIMx slave mode control register (TIMx_SMCR)(x = 1, 8)

Address offset: 0x008

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.SMSPSSMSPERes.Res.TS[4:3]Res.Res.Res.SMS[3]
rwrwrwrwrw
1514131211109876543210
ETPECEETPS[1:0]ETF[3:0]MSMTS[2:0]OCCSSMS[2:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:26 Reserved, must be kept at reset value.

Bit 25 SMSPS: SMS preload source

This bit selects whether the events that triggers the SMS[3:0] bitfield transfer from preload to active

0: The transfer is triggered by the Timer's Update event

1: The transfer is triggered by the Index event

Bit 24 SMSPE: SMS preload enable

This bit selects whether the SMS[3:0] bitfield is preloaded

0: SMS[3:0] bitfield is not preloaded

1: SMS[3:0] preload is enabled

Bits 23:22 Reserved, must be kept at reset value.

Bits 21:20 TS[4:3]: Trigger selection - bit 4:3

Refer to TS[2:0] description - bits 6:4

Bits 19:17 Reserved, must be kept at reset value.

Bit 15 ETP: External trigger polarity

This bit selects whether tim_etr_in or tim_etr_in is used for trigger operations

0: tim_etr_in is non-inverted, active at high level or rising edge.

1: tim_etr_in is inverted, active at low level or falling edge.

Bit 14 ECE: External clock enable

This bit enables External clock mode 2.

0: External clock mode 2 disabled

1: External clock mode 2 enabled. The counter is clocked by any active edge on the tim_etr signal.

Note: Setting the ECE bit has the same effect as selecting external clock mode 1 with tim_trgi connected to tim_etr (SMS = 111 and TS = 00111).

It is possible to simultaneously use external clock mode 2 with the following slave modes: reset mode, gated mode and trigger mode. Nevertheless, tim_trgi must not be connected to tim_etr in this case (TS bits must not be 00111).

If external clock mode 1 and external clock mode 2 are enabled at the same time, the external clock input is tim_etr.

Bits 13:12 ETPS[1:0]: External trigger prescaler

External trigger signal tim_etrp frequency must be at most 1/4 of TIMxCLK frequency. A prescaler can be enabled to reduce tim_etrp frequency. It is useful when inputting fast external clocks on tim_etr_in.

00: Prescaler OFF

01: tim_etr_in frequency divided by 2

10: tim_etr_in frequency divided by 4

11: tim_etr_in frequency divided by 8

Bits 11:8 ETF[3:0]: External trigger filter

This bitfield then defines the frequency used to sample tim_etrp signal and the length of the digital filter applied to tim_etrp. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, sampling is done at \(f_{DTS}\)

0001: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 2

0010: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 4

0011: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 8

0100: \(f_{SAMPLING} = f_{DTS}/2\), N = 6

0101: \(f_{SAMPLING} = f_{DTS}/2\), N = 8

0110: \(f_{SAMPLING} = f_{DTS}/4\), N = 6

0111: \(f_{SAMPLING} = f_{DTS}/4\), N = 8

1000: \(f_{SAMPLING} = f_{DTS}/8\), N = 6

1001: \(f_{SAMPLING} = f_{DTS}/8\), N = 8

1010: \(f_{SAMPLING} = f_{DTS}/16\), N = 5

1011: \(f_{SAMPLING} = f_{DTS}/16\), N = 6

1100: \(f_{SAMPLING} = f_{DTS}/16\), N = 8

1101: \(f_{SAMPLING} = f_{DTS}/32\), N = 5

1110: \(f_{SAMPLING} = f_{DTS}/32\), N = 6

1111: \(f_{SAMPLING} = f_{DTS}/32\), N = 8

Bit 7 MSM: Master/slave mode

0: No action

1: The effect of an event on the trigger input (tim_trgi) is delayed to allow a perfect synchronization between the current timer and its slaves (through tim_trgo). It is useful if we want to synchronize several timers on a single external event.

Bits 6:4 TS[2:0]: Trigger selection

This bitfield is combined with TS[4:3] bits.

This bitfield selects the trigger input to be used to synchronize the counter.

00000: Internal Trigger 0 (tim_itr0)

00001: Internal Trigger 1 (tim_itr1)

00010: Internal Trigger 2 (tim_itr2)

00011: Internal Trigger 3 (tim_itr3)

00100: tim_ti1 Edge Detector (tim_ti1f_ed)

00101: Filtered Timer Input 1 (tim_ti1fp1)

00110: Filtered Timer Input 2 (tim_ti2fp2)

00111: External Trigger input (tim_etr)

01000: Internal Trigger 4 (tim_itr4)

01001: Internal Trigger 5 (tim_itr5)

01010: Internal Trigger 6 (tim_itr6)

01011: Internal Trigger 7 (tim_itr7)

01100: Internal Trigger 8 (tim_itr8)

01101: Internal Trigger 9 (tim_itr9)

01110: Internal Trigger 10 (tim_itr10)

01111: Internal trigger 11 (tim_itr11)

10000: Internal trigger 12 (tim_itr12)

10001: Internal trigger 13 (tim_itr13)

10010: Internal trigger 14 (tim_itr14)

10011: Internal trigger 15 (tim_itr15)

Others: Reserved

See Table 456: Internal trigger connection for more details on tim_itr meaning for each Timer.

Note: These bits must be changed only when they are not used (for example when SMS = 000) to avoid wrong edge detections at the transition.

Bit 3 OCCS: OCREF clear selection

This bit is used to select the OCREF clear source.

0: tim_ocref_clr_int is connected to the tim_ocref_clr input

1: tim_ocref_clr_int is connected to tim_etr

Bits 16, 2:0 SMS[3:0]: Slave mode selection

When external signals are selected the active edge of the trigger signal (tim_trgi) is linked to the polarity selected on the external input (refer to ETP bit in TIMx_SMCR for tim_etr_in and CCxP/CCxNP bits in TIMx_CCER register for tim_ti1fp1 and tim_ti2fp2).

0000: Slave mode disabled - if CEN = 1 then the prescaler is clocked directly by the internal clock.

0001: Quadrature encoder mode 1, x2 mode- Counter counts up/down on tim_ti1fp1 edge depending on tim_ti2fp2 level.

0010: Quadrature encoder mode 2, x2 mode - Counter counts up/down on tim_ti2fp2 edge depending on tim_ti1fp1 level.

0011: Quadrature encoder mode 3, x4 mode - Counter counts up/down on both tim_ti1fp1 and tim_ti2fp2 edges depending on the level of the other input.

0100: Reset mode - Rising edge of the selected trigger input (tim_trgi) reinitializes the counter and generates an update of the registers.

0101: Gated mode - The counter clock is enabled when the trigger input (tim_trgi) is high. The counter stops (but is not reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.

0110: Trigger mode - The counter starts at a rising edge of the trigger tim_trgi (but it is not reset). Only the start of the counter is controlled.

0111: External Clock mode 1 - Rising edges of the selected trigger (tim_trgi) clock the counter.

1000: Combined reset + trigger mode - Rising edge of the selected trigger input (tim_trgi) reinitializes the counter, generates an update of the registers and starts the counter.

1001: Combined gated + reset mode - The counter clock is enabled when the trigger input (tim_trgi) is high. The counter stops and is reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.

1010: Encoder mode: Clock plus direction, x2 mode.

1011: Encoder mode: Clock plus direction, x1 mode, tim_ti2fp2 edge sensitivity is set by CC2P

1100: Encoder mode: Directional Clock, x2 mode.

1101: Encoder mode: Directional Clock, x1 mode, tim_ti1fp1 and tim_ti2fp2 edge sensitivity is set by CC1P and CC2P.

1110: Quadrature encoder mode: x1 mode, counting on tim_ti1fp1 edges only, edge sensitivity is set by CC1P.

1111: Quadrature encoder mode: x1 mode, counting on tim_ti2fp2 edges only, edge sensitivity is set by CC2P.

Note: The gated mode must not be used if tim_ti1f_ed is selected as the trigger input (TS = 00100). Indeed, tim_ti1f_ed outputs 1 pulse for each transition on TI1F, whereas the gated mode checks the level of the trigger signal.

Note: The clock of the slave peripherals (timer, ADC, ...) receiving the tim_trgo or the tim_trgo2 signals must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

43.6.4 TIMx DMA/interrupt enable register (TIMx_DIER)(x = 1, 8)

Address offset: 0x00C

Reset value: 0x0000 0000

RM0481 43.6.4column_2column_30x00C
31 30 292827 26 25 24 23 22 21 20 19 18 17 16
Res. Res. Res.Res.Res. Res. Res. Res . TERR
IE IERRIE DIRIE IDXIE Res. Res. Res. Res .
rw rw rw rw
15 14 131211 10 9 8 7 6 5 4 3 2 1 0
Res. TDE COMDE CC4DE CC3DE CC2DE CC1DE UDEBIE TIE COMIE CC4IE CC3IE CC2IE CC 1IE UIE
rw rwrwrw r w rw rw rw rw rw rw rw r w rw rw
Bit 23TERRIE: Transition error interrupt enable
Bit 22IERRIE: Index error interrupt enable
Bit 21DIRIE: Direction change interrupt enable
Bit 20IDXIE: Index interrupt enable
Bit 14TDE: Trigger DMA request enable
Bit 13COMDE: COM DMA request enable
Bit 12CC4DE: Capture/compare 4 DMA request enable
Bit 11CC3DE: Capture/compare 3 DMA request enable
Bit 10CC2DE: Capture/compare 2 DMA request enable
Bit 9CC1DE: Capture/compare 1 DMA request enable

Bits 31:24 Reserved, must be kept at reset value.

Bit 23 TERRIE: Transition error interrupt enable

Bit 22 IERRIE: Index error interrupt enable

Bit 21 DIRIE: Direction change interrupt enable

Bit 20 IDXIE: Index interrupt enable

Bits 19:15 Reserved, must be kept at reset value.

Bit 14 TDE: Trigger DMA request enable

Bit 13 COMDE: COM DMA request enable

Bit 12 CC4DE: Capture/compare 4 DMA request enable

Bit 11 CC3DE: Capture/compare 3 DMA request enable

Bit 10 CC2DE: Capture/compare 2 DMA request enable

Bit 9 CC1DE: Capture/compare 1 DMA request enable

43.6.5 TIMx status register (TIMx_SR)(x = 1, 8)

Address offset: 0x010

Reset value: 0x0000 0000

column_1column_2Bit 8 Bit 7 Bit 6 Bit 5 Bit 4UDE BI E TIE COMIE CC4IEcolumn_5column_6)column_8column_9column_10column_11column_12column_13column_14column_15RM0481
Bit 3CC3IE : Capture/compare 3 interrupt enable
Bit 2CC2IE : Capture/compare 2 interrupt enable
Bit 1CC1IE : Capture/compare 1 interrupt enable
Bit 0UI E : Update interrupt enable
Address offset:0x0 10
31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res .TERRF IERR F DIRFIDXFRes.Res. CC6IF CC5IF
rc_w 0rc_w 0rc_w 0rc_w0rc_w0rc_w 0
1514131211109876543210
Res.Res.SBIF CC4OF CC3OF CC2OF CC1OF B2IFBIFTIFCOMIF CC4IF CC3IF CC2IF CC1IFUIF
rc_w0rc_w0rc_w0rc_w0rc_w0rc_w 0rc_w 0rc_w 0rc_w 0rc_w0rc_w0rc_w0 rc_w0rc_w 0

Bits 31:24 Reserved, must be kept at reset value.

Bit 23 TERRF: Transition error interrupt flag

This flag is set by hardware when a transition error is detected in encoder mode. It is cleared by software by writing it to 0.

0: No encoder transition error has been detected.

1: An encoder transition error has been detected

Bit 22 IERRF: Index error interrupt flag

This flag is set by hardware when an index error is detected. It is cleared by software by writing it to 0.

0: No index error has been detected.

1: An index error has been detected

Bit 21 DIRF: Direction change interrupt flag

This flag is set by hardware when the direction changes in encoder mode (DIR bit value in TIMx_CR is changing). It is cleared by software by writing it to 0.

0: No direction change

1: Direction change

Bit 20 IDXF: Index interrupt flag

This flag is set by hardware when an index event is detected. It is cleared by software by writing it to 0.

0: No index event occurred.

1: An index event has occurred

Bits 19:18 Reserved, must be kept at reset value.

Bit 17 CC6IF: Compare 6 interrupt flag

Refer to CC1IF description

Note: Channel 6 can only be configured as output.

Bit 16 CC5IF: Compare 5 interrupt flag

Refer to CC1IF description

Note: Channel 5 can only be configured as output.

Bits 15:14 Reserved, must be kept at reset value.

Bit 13 SBIF: System break interrupt flag

This flag is set by hardware as soon as the system break input goes active. It can be cleared by software if the system break input is not active.

This flag must be reset to re-start PWM operation.

0: No break event occurred.

1: An active level has been detected on the system break input. An interrupt is generated if BIE = 1 in the TIMx_DIER register.

Bit 12 CC4OF: Capture/compare 4 overcapture flag

Refer to CC1OF description

Bit 11 CC3OF: Capture/compare 3 overcapture flag

Refer to CC1OF description

Bit 10 CC2OF: Capture/compare 2 overcapture flag

Refer to CC1OF description

Bit 9 CC1OF: Capture/compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to 0.

0: No overcapture has been detected.

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bit 8 B2IF: Break 2 interrupt flag

This flag is set by hardware as soon as the break 2 input goes active. It can be cleared by software if the break 2 input is not active.

0: No break event occurred.

1: An active level has been detected on the break 2 input. An interrupt is generated if BIE = 1 in the TIMx_DIER register.

Bit 7 BIF: Break interrupt flag

This flag is set by hardware as soon as the break input goes active. It can be cleared by software if the break input is not active.

0: No break event occurred.

1: An active level has been detected on the break input. An interrupt is generated if BIE = 1 in the TIMx_DIER register.

Bit 6 TIF: Trigger interrupt flag

This flag is set by hardware on the TRG trigger event (active edge detected on tim_trgi input when the slave mode controller is enabled in all modes but gated mode. It is set when the counter starts or stops when gated mode is selected. It is cleared by software.

0: No trigger event occurred.

1: Trigger interrupt pending.

Bit 5 COMIF: COM interrupt flag

This flag is set by hardware on COM event (when capture/compare Control bits - CCxE, CCxNE, OCxM - have been updated). It is cleared by software.

0: No COM event occurred.

1: COM interrupt pending.

Bit 4 CC4IF: Capture/compare 4 interrupt flag

Refer to CC1IF description

Bit 3 CC3IF: Capture/compare 3 interrupt flag

Refer to CC1IF description

Bit 2 CC2IF: Capture/compare 2 interrupt flag

Refer to CC1IF description

Bit 1 CC1IF: Capture/compare 1 interrupt flag

This flag is set by hardware. It is cleared by software (input capture or output compare mode) or by reading the TIMx_CCR1 register (input capture mode only).

0: No compare match / No input capture occurred

1: A compare match or an input capture occurred

If channel CC1 is configured as output: this flag is set when the content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register. When the content of TIMx_CCR1 is greater than the content of TIMx_ARR, the CC1IF bit goes high on the counter overflow (in up-counting and up/down-counting modes) or underflow (in downcounting mode). There are 3 possible options for flag setting in center-aligned mode, refer to the CMS bits in the TIMx_CR1 register for the full description.

If channel CC1 is configured as input: this bit is set when counter value has been captured in TIMx_CCR1 register (an edge has been detected on IC1, as per the edge sensitivity defined with the CC1P and CC1NP bits setting, in TIMx_CCER).

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

–At overflow or underflow regarding the repetition counter value (update if repetition counter = 0) and if the UDIS = 0 in the TIMx_CR1 register.

–When CNT is reinitialized by software using the UG bit in TIMx_EGR register, if URS = 0 and UDIS = 0 in the TIMx_CR1 register.

–When CNT is reinitialized by a trigger event (refer to Section 43.6.3: TIMx slave mode control register (TIMx_SMCR)(x = 1, 8)), if URS = 0 and UDIS = 0 in the TIMx_CR1 register.

43.6.6 TIMx event generation register (TIMx_EGR)(x = 1, 8)

Address offset: 0x014

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.B2GBGTGCOMGCC4GCC3GCC2GCC1GUG
wwwwwwwww

Bits 15:9 Reserved, must be kept at reset value.

Bit 8 B2G: Break 2 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A break 2 event is generated. MOE bit is cleared and B2IF flag is set. Related interrupt can occur if enabled.

Bit 7 BG: Break generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A break event is generated. MOE bit is cleared and BIF flag is set. Related interrupt or DMA transfer can occur if enabled.

Bit 6 TG: Trigger generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: The TIF flag is set in TIMx_SR register. Related interrupt or DMA transfer can occur if enabled.

Bit 5 COMG: Capture/compare control update generation

This bit can be set by software, it is automatically cleared by hardware

0: No action

1: CCxE, CCxNE and OCxM bits update (providing CCPC bit is set)

Note: This bit acts only on channels having a complementary output.

Bit 4 CC4G: Capture/compare 4 generation

Refer to CC1G description

Bit 3 CC3G: Capture/compare 3 generation

Refer to CC1G description

Bit 2 CC2G: Capture/compare 2 generation

Refer to CC1G description

Bit 1 CC1G: Capture/compare 1 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled.

If channel CC1 is configured as input:

The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected). The counter is cleared if the center-aligned mode is selected or if DIR = 0 (upcounting), else it takes the autoreload value (TIMx_ARR) if DIR = 1 (downcounting).

43.6.7 TIMx capture/compare mode register 1 (TIMx_CCMR1)
(x = 1, 8)

Address offset: 0x018

Reset value: 0x0000 0000

The same register can be used for input capture mode (this section) or for output compare mode (next section). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function for input capture and for output compare modes. It is possible to combine both modes independently (for example channel 1 in input capture mode and channel 2 in output compare mode).

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
IC2F[3:0]IC2PSC[1:0]CC2S[1:0]IC1F[3:0]IC1PSC[1:0]CC1S[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Input capture mode:

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:12 IC2F[3:0]: Input capture 2 filter

Bits 11:10 IC2PSC[1:0]: Input capture 2 prescaler

Bits 9:8 CC2S[1:0]: Capture/compare 2 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, tim_ic2 is mapped on tim_ti2

10: CC2 channel is configured as input, tim_ic2 is mapped on tim_ti1

11: CC2 channel is configured as input, tim_ic2 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = 0 in TIMx_CCER).

Bits 7:4 IC1F[3:0]: Input capture 1 filter

This bitfield defines the frequency used to sample tim_ti1 input and the length of the digital filter applied to tim_ti1. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, sampling is done at \(f_{DTS}\)

0001: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 2

0010: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 4

0011: \(f_{SAMPLING} = f_{tim\_ker\_ck}\), N = 8

0100: \(f_{SAMPLING} = f_{DTS}/2\), N = 6

0101: \(f_{SAMPLING} = f_{DTS}/2\), N = 8

0110: \(f_{SAMPLING} = f_{DTS}/4\), N = 6

0111: \(f_{SAMPLING} = f_{DTS}/4\), N = 8

1000: \(f_{SAMPLING} = f_{DTS}/8\), N = 6

1001: \(f_{SAMPLING} = f_{DTS}/8\), N = 8

1010: \(f_{SAMPLING} = f_{DTS}/16\), N = 5

1011: \(f_{SAMPLING} = f_{DTS}/16\), N = 6

1100: \(f_{SAMPLING} = f_{DTS}/16\), N = 8

1101: \(f_{SAMPLING} = f_{DTS}/32\), N = 5

1110: \(f_{SAMPLING} = f_{DTS}/32\), N = 6

1111: \(f_{SAMPLING} = f_{DTS}/32\), N = 8

Bits 3:2 IC1PSC[1:0]: Input capture 1 prescaler

This bitfield defines the ratio of the prescaler acting on CC1 input (tim_ic1). The prescaler is reset as soon as CC1E = 0 (TIMx_CCER register).

00: no prescaler, capture is done each time an edge is detected on the capture input

01: capture is done once every 2 events

10: capture is done once every 4 events

11: capture is done once every 8 events

Bits 1:0 CC1S[1:0]: Capture/compare 1 Selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, tim_ic1 is mapped on tim_ti1

10: CC1 channel is configured as input, tim_ic1 is mapped on tim_ti2

11: CC1 channel is configured as input, tim_ic1 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

43.6.8 TIMx capture/compare mode register 1 [alternate]
(TIMx_CCMR1)(x = 1, 8)

Address offset: 0x018

Reset value: 0x0000 0000

The same register can be used for output compare mode (this section) or for input capture mode (previous section). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function for input capture and for output compare modes. It is possible to combine both modes independently (for example channel 1 in input capture mode and channel 2 in output compare mode).

RM0481 Bit 5SPI5RST: SPI5 block reset
31 30 292827 26 25 24 23 22 21 20 19 18 17 16
Res. Res. Res.Res.Res. Res. Res. OC2M[3] Res. Res. Res. Res. Res. Res. Res. OC1M[3] rw rw
15 14 131211 10 9 8 7 6 5 4 3 2 1 0
OC2OC2 OC1
CE OC2M[2:0]OC2
FE CC2S[1:0] OC1
CE OC1M[2:0] OC1
PE PE FE CC1S[1:0]
rw rw rwrwrw rw rw rw rw rw rw rw rw rw rw rw
Bit 15OC2CE:Output compare 2 clear enable
Bits 24, 14:12OC2M[3:0]: Output compare 2 mode
Bit 11OC2PE: Output compare 2 preload enable
Bit 10OC2FE: Output compare 2 fast enable
Bits 9:8CC2S[1:0]: Capture/compare 2 selection

Output compare mode:

Bits 31:25 Reserved, must be kept at reset value.

Bits 23:17 Reserved, must be kept at reset value.

Bit 15 OC2CE: Output compare 2 clear enable

Bits 24, 14:12 OC2M[3:0]: Output compare 2 mode

Bit 11 OC2PE: Output compare 2 preload enable

Bit 10 OC2FE: Output compare 2 fast enable

Bits 9:8 CC2S[1:0]: Capture/compare 2 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, tim_ic2 is mapped on tim_ti2

10: CC2 channel is configured as input, tim_ic2 is mapped on tim_ti1

11: CC2 channel is configured as input, tim_ic2 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = 0 in TIMx_CCER).

Bits 16, 6:4 OC1M[3:0]: Output compare 1 mode

These bits define the behavior of the output reference signal tim_oc1ref from which tim_oc1 and tim_oc1n are derived. tim_oc1ref is active high whereas tim_oc1 and tim_oc1n active level depends on CC1P and CC1NP bits.

0000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs. This mode can be used when the timer serves as a software timebase. When the frozen mode is enabled during timer operation, the output keeps the state (active or inactive) it had before entering the frozen state.

0001: Set channel 1 to active level on match. tim_oc1ref signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

0010: Set channel 1 to inactive level on match. tim_oc1ref signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

0011: Toggle - tim_oc1ref toggles when TIMx_CNT= TIMx_CCR1.

0100: Force inactive level - tim_oc1ref is forced low.

0101: Force active level - tim_oc1ref is forced high.

0110: PWM mode 1 - In upcounting, channel 1 is active as long as TIMx_CNT< TIMx_CCR1 else inactive. In downcounting, channel 1 is inactive (tim_oc1ref= 0) as long as TIMx_CNT> TIMx_CCR1 else active (tim_oc1ref= 1).

0111: PWM mode 2 - In upcounting, channel 1 is inactive as long as TIMx_CNT< TIMx_CCR1 else active. In downcounting, channel 1 is active as long as TIMx_CNT> TIMx_CCR1 else inactive.

1000: Retriggerable OPM mode 1 - In up-counting mode, the channel is active until a trigger event is detected (on tim_trgi signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update. In down-counting mode, the channel is inactive until a trigger event is detected (on tim_trgi signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes inactive again at the next update.

1001: Retriggerable OPM mode 2 - In up-counting mode, the channel is inactive until a trigger event is detected (on tim_trgi signal). Then, a comparison is performed as in PWM mode 2 and the channels becomes inactive again at the next update. In down-counting mode, the channel is active until a trigger event is detected (on tim_trgi signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update.

1010: Reserved,

1011: Reserved,

1100: Combined PWM mode 1 - tim_oc1ref has the same behavior as in PWM mode 1. tim_oc1refc is the logical OR between tim_oc1ref and tim_oc2ref.

1101: Combined PWM mode 2 - tim_oc1ref has the same behavior as in PWM mode 2. tim_oc1refc is the logical AND between tim_oc1ref and tim_oc2ref.

1110: Asymmetric PWM mode 1 - tim_oc1ref has the same behavior as in PWM mode 1. tim_oc1refc outputs tim_oc1ref when the counter is counting up, tim_oc2ref when it is counting down.

1111: Asymmetric PWM mode 2 - tim_oc1ref has the same behavior as in PWM mode 2. tim_oc1refc outputs tim_oc1ref when the counter is counting up, tim_oc2ref when it is counting down.

Note: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S= 00 (the channel is configured in output).

Note: In PWM mode, the OCREF level changes when the result of the comparison changes, when the output compare mode switches from “frozen” mode to “PWM” mode and when the output compare mode switches from “force active/inactive” mode to “PWM” mode.

Note: On channels having a complementary output, this bitfield is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the OC1M active bits take the new value from the preloaded bits only when a COM event is generated.

Bit 3 OC1PE: Output compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.

Note: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S = 00 (the channel is configured in output).

Bit 2 OC1FE: Output compare 1 fast enable

This bit decreases the latency between a trigger event and a transition on the timer output. It must be used in one-pulse mode (OPM bit set in TIMx_CR1 register), to have the output pulse starting as soon as possible after the starting trigger.

0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.

1: An active edge on the trigger input acts like a compare match on CC1 output. Then, OC is set to the compare level independently from the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OCFE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S[1:0]: Capture/compare 1 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, tim_ic1 is mapped on tim_ti1

10: CC1 channel is configured as input, tim_ic1 is mapped on tim_ti2

11: CC1 channel is configured as input, tim_ic1 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC1S bits are writable only when the channel is OFF (CC1E = 0 in TIMx_CCER).

43.6.9 TIMx capture/compare mode register 2 (TIMx_CCMR2)
(x = 1, 8)

Address offset: 0x01C

Reset value: 0x0000 0000

The same register can be used for input capture mode (this section) or for output compare mode (next section). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function for input capture and for output compare modes. It is possible to combine both modes independently (for example channel 3 in input capture mode and channel 4 in output compare mode).

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
IC4F[3:0]IC4PSC[1:0]CC4S[1:0]IC3F[3:0]IC3PSC[1:0]CC3S[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Input capture mode

ST logo
ST logo

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:12 IC4F[3:0]: Input capture 4 filter

Bits 11:10 IC4PSC[1:0]: Input capture 4 prescaler

Bits 9:8 CC4S[1:0]: Capture/compare 4 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC4 channel is configured as output

01: CC4 channel is configured as input, tim_ic4 is mapped on tim_ti4

10: CC4 channel is configured as input, tim_ic4 is mapped on tim_ti3

11: CC4 channel is configured as input, tim_ic4 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC4S bits are writable only when the channel is OFF (CC4E = 0 in TIMx_CCER).

Bits 7:4 IC3F[3:0]: Input capture 3 filter

Bits 3:2 IC3PSC[1:0]: Input capture 3 prescaler

Bits 1:0 CC3S[1:0]: Capture/compare 3 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC3 channel is configured as output

01: CC3 channel is configured as input, tim_ic3 is mapped on tim_ti3

10: CC3 channel is configured as input, tim_ic3 is mapped on tim_ti4

11: CC3 channel is configured as input, tim_ic3 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC3S bits are writable only when the channel is OFF (CC3E = 0 in TIMx_CCER).

43.6.10 TIMx capture/compare mode register 2 [alternate]
(TIMx_CCMR2)(x = 1, 8)

Address offset: 0x01C

Reset value: 0x0000 0000

The same register can be used for output compare mode (this section) or for input capture mode (previous section). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function for input capture and for output compare modes. It is possible to combine both modes independently (for example channel 3 in input capture mode and channel 4 in output compare mode).

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.OC4M[3]Res.Res.Res.Res.Res.Res.Res.OC3M[3]
rwrw
1514131211109876543210
OC4
CE
OC4M[2:0]OC4
PE
OC4
FE
CC4S[1:0]OC3
CE
OC3M[2:0]OC3
PE
OC3
FE
CC3S[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode

Bits 31:25 Reserved, must be kept at reset value.

Bits 23:17 Reserved, must be kept at reset value.

Bit 15 OC4CE: Output compare 4 clear enable

Bits 24, 14:12 OC4M[3:0]: Output compare 4 mode

Refer to OC3M[3:0] bit description

Bit 11 OC4PE: Output compare 4 preload enable

Bit 10 OC4FE: Output compare 4 fast enable

Bits 9:8 CC4S[1:0]: Capture/compare 4 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC4 channel is configured as output

01: CC4 channel is configured as input, tim_ic4 is mapped on tim_ti4

10: CC4 channel is configured as input, tim_ic4 is mapped on tim_ti3

11: CC4 channel is configured as input, tim_ic4 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC4S bits are writable only when the channel is OFF (CC4E = 0 in TIMx_CCER).

Bit 7 OC3CE: Output compare 3 clear enable

Bits 16, 6:4 OC3M[3:0]: Output compare 3 mode

These bits define the behavior of the output reference signal tim_oc3ref from which tim_oc3 and tim_oc3n are derived. tim_oc3ref is active high whereas tim_oc3 and tim_oc3n active level depends on CC3P and CC3NP bits.

Note: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S= 00 (the channel is configured in output).

Note: In PWM mode, the OCREF level changes only when the result of the comparison changes or when the output compare mode switches from “frozen” mode to “PWM” mode.

On channels having a complementary output, this bitfield is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the OC3M active bits take the new value from the preloaded bits only when a COM event is generated.

Bit 3 OC3PE: Output compare 3 preload enable

Bit 2 OC3FE: Output compare 3 fast enable

Bits 1:0 CC3S[1:0]: Capture/compare 3 selection

This bitfield defines the direction of the channel (input/output) as well as the used input.

00: CC3 channel is configured as output

01: CC3 channel is configured as input, tim_ic3 is mapped on tim_ti3

10: CC3 channel is configured as input, tim_ic3 is mapped on tim_ti4

11: CC3 channel is configured as input, tim_ic3 is mapped on tim_trc. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC3S bits are writable only when the channel is OFF (CC3E = 0 in TIMx_CCER).

43.6.11 TIMx capture/compare enable register (TIMx_CCER)(x = 1, 8)

Address offset: 0x020

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CC6PCC6ERes.Res.CC5PCC5E
rwrwrwrw
1514131211109876543210
CC4NPCC4NECC4PCC4ECC3NPCC3NECC3PCC3ECC2NPCC2NECC2PCC2ECC1NPCC1NECC1PCC1E
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:22 Reserved, must be kept at reset value.

Bit 21 CC6P: Capture/compare 6 output polarity
Refer to CC1P description

Bit 20 CC6E: Capture/compare 6 output enable
Refer to CC1E description

Bits 19:18 Reserved, must be kept at reset value.

Bit 17 CC5P: Capture/compare 5 output polarity
Refer to CC1P description

Bit 16 CC5E: Capture/compare 5 output enable
Refer to CC1E description

Bit 15 CC4NP: Capture/compare 4 complementary output polarity
Refer to CC1NP description

Bit 14 CC4NE: Capture/compare 4 complementary output enable
Refer to CC1NE description

Bit 13 CC4P: Capture/compare 4 output polarity
Refer to CC1P description

Bit 12 CC4E: Capture/compare 4 output enable
Refer to CC1E description

Bit 11 CC3NP: Capture/compare 3 complementary output polarity
Refer to CC1NP description

Bit 1 CC1P: Capture/compare 1 output polarity

0: OC1 active high (output mode) / Edge sensitivity selection (input mode, see below)

1: OC1 active low (output mode) / Edge sensitivity selection (input mode, see below)

When CC1 channel is configured as input, both CC1NP/CC1P bits select the active polarity of TI1FP1 and TI2FP1 for trigger or capture operations.

CC1NP = 0, CC1P = 0: non-inverted/rising edge. The circuit is sensitive to TIxFP1 rising edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode or encoder mode).

CC1NP = 0, CC1P = 1: inverted/falling edge. The circuit is sensitive to TIxFP1 falling edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is inverted (trigger operation in gated mode or encoder mode).

CC1NP = 1, CC1P = 1: non-inverted/both edges/ The circuit is sensitive to both TIxFP1 rising and falling edges (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode). This configuration must not be used in encoder mode.

CC1NP = 1, CC1P = 0: the configuration is reserved, it must not be used.

Note: This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register). Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1P active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Bit 0 CC1E: Capture/compare 1 output enable

0: Capture mode disabled / OC1 is not active (see below)

1: Capture mode enabled / OC1 signal is output on the corresponding output pin

When CC1 channel is configured as output , the OC1 level depends on MOE, OSSR, OSSR, OIS1, OIS1N and CC1NE bits, regardless of the CC1E bits state. Refer to Table 471 for details. Note: On channels having a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1E active bit takes the new value from the preloaded bit only when a Commutation event is generated. Table 471. Output control bits for complementary tim_ocx and tim_ocxn channels with break feature
Control bitsOutput states(1)
MOE bitOSSI bitOSSR bitCCxE bitCCxNE bittim_ocx output statetim_ocxn output state
1XX00Output disabled (not driven by the timer: Hi-Z)
tim_ocx = 0, tim_ocxn = 0
001Output disabled (not driven by the timer: Hi-Z)
tim_ocx = 0
tim_ocxref + Polarity tim_ocxn = tim_ocxref xor CCxNP
010tim_ocxref + Polarity
tim_ocx = tim_ocxref xor CCxP
Output Disabled (not driven by the timer: Hi-Z)
tim_ocxn = 0
X11OCREF + Polarity + dead-timeComplementary to OCREF (not OCREF) + Polarity + dead-time
101Off-State (output enabled with inactive state)
tim_ocx = CCxP
tim_ocxref + Polarity
tim_ocxn = tim_ocxref x or CCxNP
110tim_ocxref + Polarity
tim_ocx = tim_ocxref xor CCxP
Off-State (output enabled with inactive state)
tim_ocxn = CCxNP
00XXXOutput disabled (not driven by the timer: Hi-Z).
100
01Off-State (output enabled with inactive state)
Asynchronously: tim_ocx = CCxP, tim_ocxn = CCxNP (if tim_brk or tim_brk2 is triggered).
10
11Then (this is valid only if tim_brk is triggered), if the clock is present: tim_ocx = OISx and tim_ocxn = OISxN after a dead-time, assuming that OISx and OISxN do not correspond to OCX and tim_ocxn both in active state (may cause a short circuit when driving switches in half-bridge configuration).
Note: tim_brk2 can only be used if OSSI = OSSR = 1.

Note: The state of the external I/O pins connected to the complementary tim_ocx and tim_ocxn channels depends on the tim_ocx and tim_ocxn channel state and the GPIO registers.

43.6.12 TIMx counter (TIMx_CNT)(x = 1, 8)

Address offset: 0x024

Reset value: 0x0000 0000

31302928272625242322212019181716
UIF
CPY
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
r
1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 31 UIFCPY: UIF copy

This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in the TIMxCR1 is reset, bit 31 is reserved and read at 0.

Bits 30:16 Reserved, must be kept at reset value.

Bits 15:0 CNT[15:0]: Counter value

Non-dithering mode (DITHEN = 0)

The register holds the counter value.

Dithering mode (DITHEN = 1)

The register only holds the non-dithered part in CNT[15:0]. The fractional part is not available.

43.6.13 TIMx prescaler (TIMx_PSC)(x = 1, 8)

Address offset: 0x028

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency (\(f_{tim\_cnt\_ck}\)) is equal to \(f_{tim\_psc\_ck} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

43.6.14 TIMx autoreload register (TIMx_ARR)(x = 1, 8)

Address offset: 0x02C

Reset value: 0x0000 FFFF

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ARR[19:16]
rwrwrwrw
1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 ARR[19:0]: Autoreload value

ARR is the value to be loaded in the actual autoreload register.

Refer to the Section 43.3.3: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the autoreload value is null.

Non-dithering mode (DITHER = 0)

The register holds the autoreload value.

Dithering mode (DITHER = 1)

The register holds the integer part in ARR[19:4]. The ARR[3:0] bitfield contains the dithered part.

43.6.15 TIMx repetition counter register (TIMx_RCR)(x = 1, 8)

Address offset: 0x030

Reset value: 0x0000

1514131211109876543210
REP[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 REP[15:0]: Repetition counter reload value

This bitfield defines the update rate of the compare registers (i.e. periodic transfers from preload to active registers) when preload registers are enable. It also defines the update interrupt generation rate, if this interrupt is enable.

When the repetition down-counter reaches zero, an update event is generated and it restarts counting from REP value. As the repetition counter is reloaded with REP value only at the repetition update event UEV, any write to the TIMx_RCR register is not taken in account until the next repetition update event.

It means in PWM mode (REP+1) corresponds to:

43.6.16 TIMx capture/compare register 1 (TIMx_CCR1)(x = 1, 8)

Address offset: 0x034

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR1[19:16]
rwrwrwrw
1514131211109876543210
CCR1[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 CCR1[19:0]: Capture/compare 1 value

If channel CC1 is configured as output: CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on tim_oc1 output.

Non-dithering mode (DITHEN = 0)

The register holds the compare value in CCR1[15:0]. The CCR1[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the integer part in CCR1[19:4]. The CCR1[3:0] bitfield contains the dithered part.

If channel CC1 is configured as input: CR1 is the counter value transferred by the last input capture 1 event (tim_ic1). The TIMx_CCR1 register is read-only and cannot be programmed.

Non-dithering mode (DITHEN = 0)

The register holds the capture value in CCR1[15:0]. The CCR1[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the capture in CCR1[19:4]. The CCR1[3:0] bits are reset.

43.6.17 TIMx capture/compare register 2 (TIMx_CCR2)(x = 1, 8)

Address offset: 0x038

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR2[19:16]
rwrwrwrw
1514131211109876543210
CCR2[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 CCR2[19:0]: Capture/compare 2 value

If channel CC2 is configured as output: CCR2 is the value to be loaded in the actual capture/compare 2 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC2PE). Else the preload value is copied in the active capture/compare 2 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on tim_oc2 output.

Non-dithering mode (DITHEN = 0)

The register holds the compare value in CCR2[15:0]. The CCR2[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the integer part in CCR2[19:4]. The CCR2[3:0] bitfield contains the dithered part.

If channel CC2 is configured as input: CCR2 is the counter value transferred by the last input capture 2 event (tim_ic2). The TIMx_CCR2 register is read-only and cannot be programmed.

Non-dithering mode (DITHEN = 0)

The register holds the capture value in CCR2[15:0]. The CCR2[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the capture in CCR2[19:4]. The CCR2[3:0] bits are reset.

43.6.18 TIMx capture/compare register 3 (TIMx_CCR3)(x = 1, 8)

Address offset: 0x03C

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR3[19:16]
rwrwrwrw
1514131211109876543210
CCR3[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 CCR3[19:0]: Capture/compare value

If channel CC3 is configured as output: CCR3 is the value to be loaded in the actual capture/compare 3 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR2 register (bit OC3PE). Else the preload value is copied in the active capture/compare 3 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on tim_oc3 output.

Non-dithering mode (DITHEN = 0)

The register holds the compare value in CCR3[15:0]. The CCR3[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the integer part in CCR3[19:4]. The CCR3[3:0] bitfield contains the dithered part.

If channel CC3 is configured as input: CCR3 is the counter value transferred by the last input capture 3 event (tim_ic3). The TIMx_CCR3 register is read-only and cannot be programmed.

Non-dithering mode (DITHEN = 0)

The register holds the capture value in CCR3[15:0]. The CCR3[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the capture in CCR3[19:4]. The CCR3[3:0] bits are reset.

43.6.19 TIMx capture/compare register 4 (TIMx_CCR4)(x = 1, 8)

Address offset: 0x040

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR4[19:16]
rwrwrwrw
1514131211109876543210
CCR4[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 CCR4[19:0]: Capture/compare value

If channel CC4 is configured as output: CCR4 is the value to be loaded in the actual capture/compare 4 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR2 register (bit OC4PE). Else the preload value is copied in the active capture/compare 4 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on tim_oc4 output.

Non-dithering mode (DITHEN = 0)

The register holds the compare value in CCR4[15:0]. The CCR4[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the integer part in CCR4[19:4]. The CCR4[3:0] bitfield contains the dithered part.

If channel CC4 is configured as input: CCR4 is the counter value transferred by the last input capture 4 event (tim_ic4). The TIMx_CCR4 register is read-only and cannot be programmed.

Non-dithering mode (DITHEN = 0)

The register holds the capture value in CCR4[15:0]. The CCR4[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the capture in CCR4[19:4]. The CCR4[3:0] bits are reset.

43.6.20 TIMx break and dead-time register (TIMx_BDTR)(x = 1, 8)

Address offset: 0x044

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.BK2BIDBKBIDBK2DSRMBKDSRMBK2PBK2EBK2F[3:0]BKF[3:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrw
1514131211109876543210
MOEAOEBKPBKEOSSROSSILOCK[1:0]DTG[7:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Note: As the bits BKBID/BK2BID/BK2P, BK2E, BK2F[3:0], BKF[3:0], AOE, BKP, BKE, OSSI, OSSR, and DTG[7:0] can be write-locked depending on the LOCK configuration, it can be necessary to configure all of them during the first write access to the TIMx_BDTR register.

Bits 31:30 Reserved, must be kept at reset value.

Bit 29 BK2BID: Break2 bidirectional
Refer to BKBID description

Bit 28 BKBID: Break bidirectional
0: Break input tim_brk in input mode
1: Break input tim_brk in bidirectional mode
In the bidirectional mode (BKBID bit set to 1), the break input is configured both in input mode and in open drain output mode. Any active break event asserts a low logic level on the Break input to indicate an internal break event to external devices.
Note: This bit cannot be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 27 BK2DSRM: Break2 disarm
Refer to BKDSRM description

Bit 26 BKDSRM: Break disarm
0: Break input tim_brk is armed
1: Break input tim_brk is disarmed
This bit is cleared by hardware when no break source is active.
The BKDSRM bit must be set by software to release the bidirectional output control (open-drain output in Hi-Z state) and then be polled it until it is reset by hardware, indicating that the fault condition has disappeared.
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 25 BK2P: Break 2 polarity
0: Break input tim_brk2 is active low
1: Break input tim_brk2 is active high
Note: This bit cannot be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 24 BK2E: Break 2 enable
This bit enables the complete break 2 protection, see Figure 451: Break and Break2 circuitry overview.
0: Break2 function disabled
1: Break2 function enabled
Note: The BRKIN2 must only be used with OSSR = OSSI = 1.
Note: This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bits 23:20 BK2F[3:0]: Break 2 filter

This bitfield defines the frequency used to sample tim_brk2 input and the length of the digital filter applied to tim_brk2. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, tim_brk2 acts asynchronously

0001: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 2

0010: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 4

0011: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 8

0100: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/2\), N = 6

0101: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/2\), N = 8

0110: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/4\), N = 6

0111: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/4\), N = 8

1000: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/8\), N = 6

1001: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/8\), N = 8

1010: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 5

1011: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 6

1100: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 8

1101: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 5

1110: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 6

1111: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 8

Note: This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 19:16 BKF[3:0]: Break filter

This bitfield defines the frequency used to sample tim_brk input and the length of the digital filter applied to tim_brk. The digital filter is made of an event counter in which N consecutive events are needed to validate a transition on the output:

0000: No filter, tim_brk acts asynchronously

0001: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 2

0010: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 4

0011: \(f_{\text{SAMPLING}} = f_{\text{tim\_ker\_ck}}\), N = 8

0100: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/2\), N = 6

0101: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/2\), N = 8

0110: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/4\), N = 6

0111: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/4\), N = 8

1000: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/8\), N = 6

1001: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/8\), N = 8

1010: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 5

1011: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 6

1100: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/16\), N = 8

1101: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 5

1110: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 6

1111: \(f_{\text{SAMPLING}} = f_{\text{DTS}}/32\), N = 8

Note: This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 15 MOE: Main output enable

This bit is cleared asynchronously by hardware as soon as one of the break inputs is active (tim_brk or tim_brk2). It is set by software or automatically depending on the AOE bit. It is acting only on the channels which are configured in output.

0: In response to a break 2 event. OC and OCN outputs are disabled

In response to a break event or if MOE is written to 0: OC and OCN outputs are disabled or forced to idle state depending on the OSSI bit.

1: OC and OCN outputs are enabled if their respective enable bits are set (CCxE, CCxNE in TIMx_CCER register).

See OC/OCN enable description for more details (Section 43.6.11: TIMx capture/compare enable register (TIMx_CCER)(x = 1, 8)).

Bit 14 AOE: Automatic output enable

0: MOE can be set only by software

1: MOE can be set by software or automatically at the next update event (if none of the break inputs tim_brk and tim_brk2 is active)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 13 BKP: Break polarity

0: Break input tim_brk is active low

1: Break input tim_brk is active high

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 12 BKE: Break enable

This bit enables the complete break protection (including all sources connected to tim_sys_brk and BKIN sources, as per Figure 451: Break and Break2 circuitry overview).

0: Break function disabled

1: Break function enabled

Note: This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 11 OSSR: Off-state selection for Run mode

This bit is used when MOE = 1 on channels having a complementary output which are configured as outputs. OSSR is not implemented if no complementary output is implemented in the timer.

See OC/OCN enable description for more details (Section 43.6.11: TIMx capture/compare enable register (TIMx_CCER)(x = 1, 8)).

0: When inactive, OC/OCN outputs are disabled (the timer releases the output control which is taken over by the GPIO logic, which forces a Hi-Z state).

1: When inactive, OC/OCN outputs are enabled with their inactive level as soon as CCxE = 1 or CCxNE = 1 (the output is still controlled by the timer).

Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 10 OSSI: Off-state selection for idle mode

This bit is used when MOE = 0 due to a break event or by a software write, on channels configured as outputs.

See OC/OCN enable description for more details (Section 43.6.11: TIMx capture/compare enable register (TIMx_CCER)(x = 1, 8)).

0: When inactive, OC/OCN outputs are disabled (the timer releases the output control which is taken over by the GPIO logic and which imposes a Hi-Z state).

1: When inactive, OC/OCN outputs are first forced with their inactive level then forced to their idle level after the deadtime. The timer maintains its control over the output.

Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 9:8 LOCK[1:0]: Lock configuration

These bits offer a write protection against software errors.

00: LOCK OFF - No bit is write protected.

01: LOCK Level 1 = DTG bits in TIMx_BDTR register, OISx and OISxN bits in TIMx_CR2 register and BKBID/BK2BID/BKE/BKP/AOE bits in TIMx_BDTR register can no longer be written.

10: LOCK Level 2 = LOCK Level 1 + CC Polarity bits (CCxP/CCxNP bits in TIMx_CCER register, as long as the related channel is configured in output through the CCxS bits) as well as OSSR and OSSI bits can no longer be written.

11: LOCK Level 3 = LOCK Level 2 + CC Control bits (OCxM and OCxPE bits in TIMx_CCMRx registers, as long as the related channel is configured in output through the CCxS bits) can no longer be written.

Note: The LOCK bits can be written only once after the reset. Once the TIMx_BDTR register has been written, their content is frozen until the next reset.

Bits 7:0 DTG[7:0]: Dead-time generator setup

This bitfield defines the duration of the dead-time inserted between the complementary outputs. DT correspond to this duration.

DTG[7:5] = 0xx => DT = DTG[7:0]x \(t_{dtg}\) with \(t_{dtg} = t_{DTS}\).

DTG[7:5] = 10x => DT = (64+DTG[5:0])x\(t_{dtg}\) with \(T_{dtg} = 2xt_{DTS}\).

DTG[7:5] = 110 => DT = (32+DTG[4:0])x\(t_{dtg}\) with \(T_{dtg} = 8xt_{DTS}\).

DTG[7:5] = 111 => DT = (32+DTG[4:0])x\(t_{dtg}\) with \(T_{dtg} = 16xt_{DTS}\).

Example if \(T_{DTS} = 125\) ns (8 MHz), dead-time possible values are:

0 to 15875 ns by 125 ns steps,

16 μs to 31750 ns by 250 ns steps,

32 μs to 63 μs by 1 μs steps,

64 μs to 126 μs by 2 μs steps

Note: This bitfield can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

43.6.21 TIMx capture/compare register 5 (TIMx_CCR5)(x = 1, 8)

Address offset: 0x048

Reset value: 0x0000 0000

31302928272625242322212019181716
GC5C3GC5C2GC5C1ResResResResResResResResResCCR5[19:16]
rwrwrwrwrwrwrw
1514131211109876543210
CCR5[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 31 GC5C3: Group channel 5 and channel 3

Distortion on channel 3 output:

0: No effect of tim_oc5ref on tim_oc3refc

1: tim_oc3refc is the logical AND of tim_oc3ref and tim_oc5ref

This bit can either have immediate effect or be preloaded and taken into account after an update event (if preload feature is selected in TIMxCCMR2).

Note: it is also possible to apply this distortion on combined PWM signals.

Bit 30 GC5C2: Group channel 5 and channel 2

Distortion on channel 2 output:

0: No effect of tim_oc5ref on tim_oc2refc

1: tim_oc2refc is the logical AND of tim_oc2ref and tim_oc5ref

This bit can either have immediate effect or be preloaded and taken into account after an update event (if preload feature is selected in TIMxCCMR1).

Note: it is also possible to apply this distortion on combined PWM signals.

Bit 29 GC5C1: Group channel 5 and channel 1

Distortion on channel 1 output:

0: No effect of oc5ref on oc1refc

1: oc1refc is the logical AND of oc1ref and oc5ref

This bit can either have immediate effect or be preloaded and taken into account after an update event (if preload feature is selected in TIMxCCMR1).

Note: it is also possible to apply this distortion on combined PWM signals.

Bits 28:20 Reserved, must be kept at reset value.

Bits 19:0 CCR5[19:0]: Capture/compare 5 value

CCR5 is the value to be loaded in the actual capture/compare 5 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR3 register (bit OC5PE). Else the preload value is copied in the active capture/compare 5 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on tim_oc5 output.

Non-dithering mode (DITHER = 0)

The register holds the compare value in CCR5[15:0]. The CCR5[19:16] bits are reset.

Dithering mode (DITHER = 1)

The register holds the integer part in CCR5[19:4]. The CCR5[3:0] bitfield contains the dithered part.

43.6.22 TIMx capture/compare register 6 (TIMx_CCR6)(x = 1, 8)

Address offset: 0x04C

Reset value: 0x0000 0000

31302928272625242322212019181716
ResResResResResResResResResResResResCCR6[19:16]
rwrwrwrw
1514131211109876543210
CCR6[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 CCR6[19:0]: Capture/compare 6 value

CCR6 is the value to be loaded in the actual capture/compare 6 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR3 register (bit OC6PE). Else the preload value is copied in the active capture/compare 6 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on tim_oc6 output.

Non-dithering mode (DITHEN = 0)

The register holds the compare value in CCR6[15:0]. The CCR6[19:16] bits are reset.

Dithering mode (DITHEN = 1)

The register holds the integer part in CCR6[19:4]. The CCR6[3:0] bitfield contains the dithered part.

43.6.23 TIMx capture/compare mode register 3 (TIMx_CCMR3)
(x = 1, 8)

Address offset: 0x050

Reset value: 0x0000 0000

Refer to the above CCMR1 register description. Channels 5 and 6 can only be configured in output.

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.OC6M[3]Res.Res.Res.Res.Res.Res.Res.OC5M[3]
rwrw
1514131211109876543210
OC6
CE
OC6M[2:0]OC6
PE
OC6FERes.Res.OC5
CE
OC5M[2:0]OC5PEOC5FERes.Res.
rwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:25 Reserved, must be kept at reset value.

Bits 23:17 Reserved, must be kept at reset value.

Bit 15 OC6CE: Output compare 6 clear enable

Bits 24, 14:12 OC6M[3:0]: Output compare 6 mode

Bit 11 OC6PE: Output compare 6 preload enable

Bit 10 OC6FE: Output compare 6 fast enable

Bits 9:8 Reserved, must be kept at reset value.

Bit 7 OC5CE: Output compare 5 clear enable

Bits 16, 6:4 OC5M[3:0]: Output compare 5 mode

Bit 3 OC5PE: Output compare 5 preload enable

Bit 2 OC5FE: Output compare 5 fast enable

Bits 1:0 Reserved, must be kept at reset value.

43.6.24 TIMx timer deadtime register 2 (TIMx_DTR2)(x = 1, 8)

Address offset: 0x054

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DTPEDTAE
rwrw
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.DTGF[7:0]
rwrwrwrwrwrwrwrw

Bits 31:18 Reserved, must be kept at reset value.

Bit 17 DTPE: Deadtime preload enable

0: Deadtime value is not preloaded

1: Deadtime value preload is enabled

Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 16 DTAE: Deadtime asymmetric enable

0: Deadtime on rising and falling edges are identical, and defined with DTG[7:0] register

1: Deadtime on rising edge is defined with DTG[7:0] register and deadtime on falling edge is defined with DTGF[7:0] bits.

Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 15:8 Reserved, must be kept at reset value.

Bits 7:0 DTGF[7:0]: Dead-time falling edge generator setup

This bitfield defines the duration of the dead-time inserted between the complementary outputs, on the falling edge.

\(DTGF[7:5] = 0xx \Rightarrow DTF = DTGF[7:0] \times t_{dtg}\) with \(t_{dtg} = t_{DTS}\).

\(DTGF[7:5] = 10x \Rightarrow DTF = (64 + DTGF[5:0]) \times t_{dtg}\) with \(T_{dtg} = 2 \times t_{DTS}\).

\(DTGF[7:5] = 110 \Rightarrow DTF = (32 + DTGF[4:0]) \times t_{dtg}\) with \(T_{dtg} = 8 \times t_{DTS}\).

\(DTGF[7:5] = 111 \Rightarrow DTF = (32 + DTGF[4:0]) \times t_{dtg}\) with \(T_{dtg} = 16 \times t_{DTS}\).

Example if \(T_{DTS} = 125\) ns (8 MHz), dead-time possible values are:

0 to 15875 ns by 125 ns steps,

16 μs to 31750 ns by 250 ns steps,

32 μs to 63 μs by 1 μs steps,

64 μs to 126 μs by 2 μs steps

Note: This bitfield can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

43.6.25 TIMx timer encoder control register (TIMx_ECR)(x = 1, 8)

Address offset: 0x058

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.PWPRSC[2:0]PW[7:0]
rwrwrwrwrwrwrwrwrwrwrw
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.IPOS[1:0]FIDXIBLK[1:0]IDIR[1:0]IE
rwrwrwrwrwrwrwrw

Bits 31:27 Reserved, must be kept at reset value.

Bits 26:24 PWPRSC[2:0]: Pulse width prescaler

This bitfield sets the clock prescaler for the pulse generator, as following:

\[t_{PWG} = (2^{(PWPRSC[2:0])}) \times t_{tim\_ker\_ck}\]

Bits 23:16 PW[7:0]: Pulse width

This bitfield defines the pulse duration, as following:

\[t_{PW} = PW[7:0] \times t_{PWG}\]

Bits 15:8 Reserved, must be kept at reset value.

Bits 7:6 IPOS[1:0]: Index positioning

In quadrature encoder mode (SMS[3:0] = 0001, 0010, 0011, 1110, 1111), this bit indicates in which AB input configuration the Index event resets the counter.

In directional clock mode or clock plus direction mode (SMS[3:0] = 1010, 1011, 1100, 1101), these bits indicates on which level the Index event resets the counter. In bidirectional clock mode, this applies for both clock inputs.

Note: IPOS[1] bit is not significant

Bit 5 FIDX: First index

This bit indicates if the first index only is taken into account

Bits 4:3 IBLK[1:0]: Index blanking

This bit indicates if the Index event is conditioned by the tim_ti3 or tim_ti4 input

00: Index always active

01: Index disabled when tim_ti3 input is active, as per CC3P bitfield

10: Index disabled when tim_ti4 input is active, as per CC4P bitfield

11: Reserved

Bits 2:1 IDIR[1:0]: Index direction

This bit indicates in which direction the Index event resets the counter.

00: Index resets the counter whatever the direction

01: Index resets the counter when up-counting only

10: Index resets the counter when down-counting only

11: Reserved

Bit 0 IE: Index enable

This bit indicates if the Index event resets the counter.

0: Index disabled

1: Index enabled

43.6.26 TIMx timer input selection register (TIMx_TISEL)(x = 1, 8)

Address offset: 0x05C

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.TI4SEL[3:0]Res.Res.Res.Res.TI3SEL[3:0]
rwrwrwrwrwrwrwrw
1514131211109876543210
Res.Res.Res.Res.TI2SEL[3:0]Res.Res.Res.Res.TI1SEL[3:0]
rwrwrwrwrwrwrwrw

Bits 31:28 Reserved, must be kept at reset value.

Bits 27:24 TI4SEL[3:0]: Selects tim_ti4[15:0] input

0000: tim_ti4_in0: TIMx_CH4

0001: tim_ti4_in1

...

1111: tim_ti4_in15

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for interconnects list.

Bits 23:20 Reserved, must be kept at reset value.

Bits 19:16 TI3SEL[3:0]: Selects tim_ti3[15:0] input

0000: tim_ti3_in0: TIMx_CH2

0001: tim_ti3_in1

...

1111: tim_ti3_in15

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for interconnects list.

Bits 15:12 Reserved, must be kept at reset value.

Bits 11:8 TI2SEL[3:0]: Selects tim_ti2[15:0] input

0000: tim_ti2_in0: TIMx_CH2

0001: tim_ti2_in1

...

1111: tim_ti2_in15

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for interconnects list.

Bits 7:4 Reserved, must be kept at reset value.

Bits 3:0 TI1SEL[3:0]: Selects tim_ti1[15:0] input

0000: tim_ti1_in0: TIMx_CH1

0001: tim_ti1_in1

...

1111: tim_ti1_in15

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for interconnects list.

43.6.27 TIMx alternate function option register 1 (TIMx_AF1)(x = 1, 8)

Address offset: 0x060

Reset value: 0x0000 0001

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ETRSEL[3:2]
rwrw
1514131211109876543210
ETRSEL[1:0]BK
CMP4P
BK
CMP3P
BK
CMP2P
BK
CMP1P
BKINPBK
CMP8E
BK
CMP7E
BK
CMP6E
BK
CMP5E
BK
CMP4E
BK
CMP3E
BK
CMP2E
BK
CMP1E
BKINE
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:18 Reserved, must be kept at reset value.

Bits 17:14 ETRSEL[3:0]: etr_in source selection

These bits select the etr_in input source.

0000: tim_etr0: TIMx_ETR input

0001: tim_etr1

...

1111: tim_etr15

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for product specific implementation.

Note: These bits can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 13 BKCMP4P: tim_brk_cmp4 input polarity

This bit selects the tim_brk_cmp4 input sensitivity. It must be programmed together with the BKP polarity bit.

0: tim_brk_cmp4 input polarity is not inverted (active low if BKP = 0, active high if BKP = 1)

1: tim_brk_cmp4 input polarity is inverted (active high if BKP = 0, active low if BKP = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 12 BKCMP3P: tim_brk_cmp3 input polarity

This bit selects the tim_brk_cmp3 input sensitivity. It must be programmed together with the BKP polarity bit.

0: tim_brk_cmp3 input polarity is not inverted (active low if BKP = 0, active high if BKP = 1)

1: tim_brk_cmp3 input polarity is inverted (active high if BKP = 0, active low if BKP = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 11 BKCMP2P: tim_brk_cmp2 input polarity

This bit selects the tim_brk_cmp2 input sensitivity. It must be programmed together with the BKP polarity bit.

0: tim_brk_cmp2 input polarity is not inverted (active low if BKP = 0, active high if BKP = 1)

1: tim_brk_cmp2 input polarity is inverted (active high if BKP = 0, active low if BKP = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 10 BKCMP1P: tim_brk_cmp1 input polarity

This bit selects the tim_brk_cmp1 input sensitivity. It must be programmed together with the BKP polarity bit.

0: tim_brk_cmp1 input polarity is not inverted (active low if BKP = 0, active high if BKP = 1)

1: tim_brk_cmp1 input polarity is inverted (active high if BKP = 0, active low if BKP = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 9 BKINP: TIMx_BKIN input polarity

This bit selects the TIMx_BKIN alternate function input sensitivity. It must be programmed together with the BKP polarity bit.

0: TIMx_BKIN input polarity is not inverted (active low if BKP = 0, active high if BKP = 1)

1: TIMx_BKIN input polarity is inverted (active high if BKP = 0, active low if BKP = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 8 BKCMP8E: tim_brk_cmp8 enable

This bit enables the tim_brk_cmp8 for the timer's tim_brk input. tim_brk_cmp8 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp8 input disabled

1: tim_brk_cmp8 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 7 BKCMP7E: tim_brk_cmp7 enable

This bit enables the tim_brk_cmp7 for the timer's tim_brk input. tim_brk_cmp7 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp7 input disabled

1: tim_brk_cmp7 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 6 BKCMP6E: tim_brk_cmp6 enable

This bit enables the tim_brk_cmp6 for the timer's tim_brk input. tim_brk_cmp6 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp6 input disabled

1: tim_brk_cmp6 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 5 BKCMP5E: tim_brk_cmp5 enable

This bit enables the tim_brk_cmp5 for the timer's tim_brk input. tim_brk_cmp5 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp5 input disabled

1: tim_brk_cmp5 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 4 BKCMP4E: tim_brk_cmp4 enable

This bit enables the tim_brk_cmp4 for the timer's tim_brk input. tim_brk_cmp4 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp4 input disabled

1: tim_brk_cmp4 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 3 BKCMP3E: tim_brk_cmp3 enable

This bit enables the tim_brk_cmp3 for the timer's tim_brk input. tim_brk_cmp3 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp3 input disabled

1: tim_brk_cmp3 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 2 BKCMP2E: tim_brk_cmp2 enable

This bit enables the tim_brk_cmp2 for the timer's tim_brk input. tim_brk_cmp2 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp2 input disabled

1: tim_brk_cmp2 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 1 BKCMP1E: tim_brk_cmp1 enable

This bit enables the tim_brk_cmp1 for the timer's tim_brk input. tim_brk_cmp1 output is 'ORed' with the other tim_brk sources.

0: tim_brk_cmp1 input disabled

1: tim_brk_cmp1 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 0 BKINE: TIMx_BKIN input enable

This bit enables the TIMx_BKIN alternate function input for the timer's tim_brk input. TIMx_BKIN input is 'ORed' with the other tim_brk sources.

0: TIMx_BKIN input disabled

1: TIMx_BKIN input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for product specific implementation.

43.6.28 TIMx alternate function register 2 (TIMx_AF2)(x = 1, 8)

Address offset: 0x064

Reset value: 0x0000 0001

RM0481 Bit 5SPI5RST: SPI5 block reset
31 30 292827 26 25 24 23 22 21 20 19 18 17 16
Res. Res. Res.Res.Res. Res. Res. Res. Res. Res. Res. Res. Res. OCRSEL[2:0]
rw rw rw
15 14 131211 10 9 8 7 6 5 4 3 2 1 0
Res. Res. BK2CBK2CBK2C BK2C BK2IN BK2CM BK2C BK2C BK2C BK2C BK2CMP BK2CMP BK2CM
MP4PMP3PMP2P MP1P P P8E MP7E MP6E MP5E MP4E 3E 2E P1E BK2INE
rwrwrw rw rw rw rw rw rw rw rw rw rw rw
Bits 18:16OCRSEL[2:0] : ocref_clr source selection
Refer to111: tim_ocref_clr7 Section 43.3.2: TIM1/TIM8 pins and internal signals for product specific information.
Bit 13BK2CMP4P: tim_brk2_cmp4 input polarity
Bit 12BK2CMP3Pin TIMx_BDTR register). : tim_brk2_cmp3 input polarity
Bit 11BK2CMP2Pin TIMx_BDTR register). : tim_brk2_cmp2 input polarity

Bits 31:19 Reserved, must be kept at reset value.

Bits 18:16 OCRSEL[2:0]: ocref_clr source selection

These bits select the ocref_clr input source.

000: tim_ocref_clr0

001: tim_ocref_clr1

...

111: tim_ocref_clr7

Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for product specific information.

Note: These bits can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 15:14 Reserved, must be kept at reset value.

Bit 13 BK2CMP4P: tim_brk2_cmp4 input polarity

This bit selects the tim_brk2_cmp4 input sensitivity. It must be programmed together with the BK2P polarity bit.

0: tim_brk2_cmp4 input polarity is not inverted (active low if BK2P = 0, active high if BK2P = 1)

1: tim_brk2_cmp4 input polarity is inverted (active high if BK2P = 0, active low if BK2P = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 12 BK2CMP3P: tim_brk2_cmp3 input polarity

This bit selects the tim_brk2_cmp3 input sensitivity. It must be programmed together with the BK2P polarity bit.

0: tim_brk2_cmp3 input polarity is not inverted (active low if BK2P = 0, active high if BK2P = 1)

1: tim_brk2_cmp3 input polarity is inverted (active high if BK2P = 0, active low if BK2P = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 11 BK2CMP2P: tim_brk2_cmp2 input polarity

This bit selects the tim_brk2_cmp2 input sensitivity. It must be programmed together with the BK2P polarity bit.

0: tim_brk2_cmp2 input polarity is not inverted (active low if BK2P = 0, active high if BK2P = 1)

1: tim_brk2_cmp2 input polarity is inverted (active high if BK2P = 0, active low if BK2P = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 10 BK2CMP1P: tim_brk2_cmp1 input polarity

This bit selects the tim_brk2_cmp1 input sensitivity. It must be programmed together with the BK2P polarity bit.

0: tim_brk2_cmp1 input polarity is not inverted (active low if BK2P = 0, active high if BK2P = 1)

1: tim_brk2_cmp1 input polarity is inverted (active high if BK2P = 0, active low if BK2P = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 9 BK2INP: TIMx_BKIN2 input polarity

This bit selects the TIMx_BKIN2 alternate function input sensitivity. It must be programmed together with the BK2P polarity bit.

0: TIMx_BKIN2 input polarity is not inverted (active low if BK2P = 0, active high if BK2P = 1)

1: TIMx_BKIN2 input polarity is inverted (active high if BK2P = 0, active low if BK2P = 1)

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 8 BK2CMP8E: tim_brk2_cmp8 enable

This bit enables the tim_brk2_cmp8 for the timer's tim_brk2 input. tim_brk2_cmp8 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp8 input disabled

1: tim_brk2_cmp8 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 7 BK2CMP7E: tim_brk2_cmp7 enable

This bit enables the tim_brk2_cmp7 for the timer's tim_brk2 input. tim_brk2_cmp7 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp7 input disabled

1: tim_brk2_cmp7 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 6 BK2CMP6E: tim_brk2_cmp6 enable

This bit enables the tim_brk2_cmp6 for the timer's tim_brk2 input. tim_brk2_cmp6 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp6 input disabled

1: tim_brk2_cmp6 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 5 BK2CMP5E: tim_brk2_cmp5 enable

This bit enables the tim_brk2_cmp5 for the timer's tim_brk2 input. tim_brk2_cmp5 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp5 input disabled

1: tim_brk2_cmp5 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 4 BK2CMP4E: tim_brk2_cmp4 enable

This bit enables the tim_brk2_cmp4 for the timer's tim_brk2 input. tim_brk2_cmp4 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp4 input disabled

1: tim_brk2_cmp4 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 3 BK2CMP3E: tim_brk2_cmp3 enable

This bit enables the tim_brk2_cmp3 for the timer's tim_brk2 input. tim_brk2_cmp3 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp3 input disabled

1: tim_brk2_cmp3 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 2 BK2CMP2E: tim_brk2_cmp2 enable

This bit enables the tim_brk2_cmp2 for the timer's tim_brk2 input. tim_brk2_cmp2 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp2 input disabled

1: tim_brk2_cmp2 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 1 BK2CMP1E: tim_brk2_cmp1 enable

This bit enables the tim_brk2_cmp1 for the timer's tim_brk2 input. tim_brk2_cmp1 output is 'ORed' with the other tim_brk2 sources.

0: tim_brk2_cmp1 input disabled

1: tim_brk2_cmp1 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Bit 0 BK2INE: TIMx_BKIN2 input enable

This bit enables the TIMx_BKIN2 alternate function input for the timer's tim_brk2 input. TIMx_BKIN2 input is 'ORed' with the other tim_brk2 sources.

0: TIMx_BKIN2 input disabled

1: TIMx_BKIN2 input enabled

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Refer to Section 43.3.2: TIM1/TIM8 pins and internal signals for product specific implementation.

43.6.29 TIMx DMA control register (TIMx_DCR)(x = 1, 8)

Address offset: 0x3DC

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DBSS[3:0]
rwrwrwrw
1514131211109876543210
Res.Res.Res.DBL[4:0]Res.Res.Res.DBA[4:0]
rwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:16 DBSS[3:0]: DMA burst source selection

This bitfield defines the interrupt source that triggers the DMA burst transfers (the timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address).

0000: Reserved
0001: Update
0010: CC1
0011: CC2
0100: CC3
0101: CC4
0110: COM
0111: Trigger
Others: reserved

Bits 15:13 Reserved, must be kept at reset value.

Bits 12:8 DBL[4:0]: DMA burst length

This 5-bit vector defines the length of DMA transfers (the timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address), i.e. the number of transfers. Transfers can be in half-words or in bytes (see example below).

00000: 1 transfer
00001: 2 transfers
00010: 3 transfers

...

11010: 26 transfers

Example: Let us consider the following transfer: DBL = 7 bytes & DBA = TIM2_CR1.

–If DBL = 7 bytes and DBA = TIM2_CR1 represents the address of the byte to be transferred, the address of the transfer is given by the following equation:

\((\text{TIMx\_CR1 address}) + \text{DBA} + (\text{DMA index})\), where DMA index = DBL

In this example, 7 bytes are added to (TIMx\_CR1 address)+DBA, which gives us the address from/to which the data are copied. In this case, the transfer is done to 7 registers starting from the following address: (TIMx\_CR1 address)+DBA

According to the configuration of the DMA Data Size, several cases may occur:

–If the DMA Data Size is configured in half-words, 16-bit data are transferred to each of the 7 registers.

–If the DMA Data Size is configured in bytes, the data are also transferred to 7 registers: the first register contains the first MSB byte, the second register, the first LSB byte and so on. So with the transfer Timer, one also has to specify the size of data transferred by DMA.

Bits 7:5 Reserved, must be kept at reset value.

Bits 4:0 DBA[4:0]: DMA base address

This 5-bits vector defines the base-address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.

Example:

00000: TIMx_CR1
00001: TIMx_CR2
00010: TIMx_SMCR

...

43.6.30 TIMx DMA address for full transfer (TIMx_DMAR)(x = 1, 8)

Address offset: 0x3E0

Reset value: 0x0000 0000

31302928272625242322212019181716
DMAB[31:16]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
1514131211109876543210
DMAB[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:0 DMAB[31:0]: DMA register for burst accesses

A read or write operation to the DMAR register accesses the register located at the address (TIMx_CR1 address) + (DBA + DMA index) x 4

where TIMx_CR1 address is the address of the control register 1, DBA is the DMA base address configured in TIMx_DCR register, DMA index is automatically controlled by the DMA transfer, and ranges from 0 to DBL (DBL configured in TIMx_DCR).

43.6.31 TIMx register map

TIMx registers are mapped as 16-bit addressable registers as described in the table below:

Table 472. TIMx register map and reset values

OffsetRegister name313029282726252423222120191817161514131211109876543210
0x000TIMx_CR1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DITHENUIFREMAPRes.CKD [1:0]ARPECMS [1:0]DIROPMURSUDISCEN
Reset value000000000000
0x004TIMx_CR2Res.Res.Res.Res.Res.Res.MMS[3]Res.MMS2[3:0]Res.OIS6Res.OIS5OIS4NOIS4OIS3NOIS3OIS2NOIS2OIS1NOIS1TI1SMMS [2:0]CCDSCCUSRes.CCPC
Reset value0000000000000000000000
0x008TIMx_SMCRRes.Res.Res.Res.Res.Res.SMSPSSMSPERes.Res.TS [4:3]Res.Res.Res.SMS[3]ETPECEETPS [1:0]ETF[3:0]MSMTS[2:0]OCCSSMS[2:0]
Reset value000000000000000000000
0x00CTIMx_DIERRes.Res.Res.Res.Res.Res.Res.Res.TERRIEIERRIEDIRIEIDXIERes.Res.Res.Res.Res.Res.Res.TDECOMDECC4DECC3DECC2DECC1DEUDEBIETIECOMIECC4IECC3IECC2IECC1IEUIE
Reset value0000000000000000000
0x010TIMx_SRRes.Res.Res.Res.Res.Res.Res.Res.TERRFIERRFDIRFIDXFRes.Res.CC6IFCC5IFRes.Res.Res.SBIFCC4OFCC3OFCC2OFCC1OFB2IFBIFTIFCOMIFCC4IFCC3IFCC2IFCC1IFUIF
Reset value00000000000000000000
0x014TIMx_EGRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.B2GBGTGCOMGCC4GCC3GCC2GCC1GUG
Reset value000000000

Table 472. TIMx register map and reset values (continued)

OffsetRegister name313029282726252423222120191817161514131211109876543210
0x018TIMx_CCMR1
Input Capture
mode
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.IC2F[3:0]IC2
PSC
[1:0]
CC2
S
[1:0]
IC1F[3:0]IC1
PSC
[1:0]
CC1
S
[1:0]
Reset value000000000000000
TIMx_CCMR1
Output
Compare mode
Res.Res.Res.Res.Res.Res.Res.OC2M[3]Res.Res.Res.Res.Res.Res.Res.OC1M[3]OC2CEOC2M
[2:0]
OC2PEOC2FECC2
S
[1:0]
OC1CEOC1M
[2:0]
OC1PEOC1FECC1
S
[1:0]
Reset value00000000000000000
0x01CTIMx_CCMR2Res.Res.Res.Res.Res.Res.Res.OC4M[3]Res.Res.Res.Res.Res.Res.Res.OC3M[3]OC4CEOC4M
[2:0]
OC4PEOC4FECC4
S
[1:0]
OC3CEOC3M
[2:0]
OC3PEOC3FECC3
S
[1:0]
Reset value00000000000000000
TIMx_CCMR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.IC4F[3:0]IC4
PSC
[1:0]
CC4
S
[1:0]
IC3F[3:0]IC3
PSC
[1:0]
CC3
S
[1:0]
Reset value0000000000000000
0x020TIMx_CCERRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.CC6PCC6ERes.Res.CC5PCC5ECC4NPCC4NECC4PCC4ECC3NPCC3NECC3PCC3ECC2NPCC2NECC2PCC2ECC1NPCC1NECC1PCC1E
Reset value0000000000000000000
0x024TIMx_CNTUIFCPYRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CNT[15:0]
Reset value00000000000000000
0x028TIMx_PSCRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.PSC[15:0]
Reset value0000000000000000
0x02CTIMx_ARRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ARR[19:0]
Reset value0000111111111111111
0x030TIMx_RCRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.REP[15:0]
Reset value0000000000000000
0x034TIMx_CCR1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR1[19:0]
Reset value000000000000000000
0x038TIMx_CCR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR2[19:0]
Reset value000000000000000000
0x03CTIMx_CCR3Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR3[19:0]
Reset value000000000000000000
0x040TIMx_CCR4Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR4[19:0]
Reset value0000000000000000000
0x044TIMx_BDTRRes.Res.BK2BIDBKBIDBK2DSRMBKDSRMBK2PBK2EBK2F[3:0]BKF[3:0]MOEAOEBKPBKEOSSROSSILOC
K
[1:0]
DT[7:0]
Reset value00000000000000000000000000000

Table 472. TIMx register map and reset values (continued)

OffsetRegister name313029282726252423222120191817161514131211109876543210
0x048TIMx_CCR5GC5C3GC5C2GC5C1Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR5[19:0]
Reset value00000000000000000000000
0x04CTIMx_CCR6Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CCR6[19:0]
Reset value00000000000000000000
0x050TIMx_CCMR3Res.Res.Res.Res.Res.Res.Res.OC6M[3]Res.Res.Res.Res.Res.Res.Res.OC5M[3]OC6CEOC6M
[2:0]
OC6PEOC6FERes.Res.OC5CEOC5M
[2:0]
OC5PEOC5FERes.Res.
Reset value00000000000000
0x054TIMx_DTR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DTPEDTAERes.Res.Res.Res.Res.Res.Res.Res.DTGF[7:0]
Reset value0000000000
0x058TIMx_ECRRes.Res.Res.Res.Res.PWPRSC[2:0]PW[7:0]Res.Res.Res.Res.Res.Res.Res.Res.IPOS[1:0]FIDXIBLK[1:0]IDIR[1:0]IE
Reset value0000000000000000000
0x05CTIMx_TISELRes.Res.Res.Res.TI4SEL[3:0]Res.Res.Res.Res.TI3SEL[3:0]Res.Res.Res.Res.TI2SEL[3:0]Res.Res.Res.Res.TI1SEL[3:0]
Reset value0000000000000000
0x060TIMx_AF1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
ETRSEL
[3:0]
BKCOMP4PBKCOMP3PBKCOMP2PBKCOMP1PBKINPBKCOMP8EBKCOMP7EBKCOMP6EBKCOMP5EBKCOMP4EBKCOMP3EBKCOMP2EBKCOMP1EBKINE
Reset value000000000000000001
0x064TIMx_AF2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.OCRSEL
[2:0]
Res.Res.BK2CMP4PBK2CMP3PBK2CMP2PBK2CMP1PBK2INPBK2CMP8EBK2CMP7EBK2CMP6EBK2CMP5EBK2CMP4EBK2CMP3EBK2CMP2EBK2CMP1EBK2INE
Reset value00000000000000001
0x068..
0x3D8
ReservedRes.
0x3DCTIMx_DCRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DBSS[3:0]Res.Res.Res.DBL[4:0]Res.Res.Res.DBA[4:0]
Reset value00000000000000
0x3E0TIMx_DMARDMAB[31:0]
Reset value00000000000000000000000000000000