45. Basic timers (TIM6/TIM7)
45.1 TIM6/TIM7 introduction
The basic timers TIM6/TIM7 consist in a 16-bit autoreload counter driven by a programmable prescaler.
They can be used as generic timers for time-base generation.
The basic timer can also be used for triggering the digital-to-analog converter. This is done with the trigger output of the timer.
The timers are completely independent, and do not share any resources.
45.2 TIM6/TIM7 main features
Basic timer (TIM6/TIM7) features include:
- • 16-bit autoreload upcounter.
- • 16-bit programmable prescaler used to divide (also “on the fly”) the counter clock frequency by any factor between 1 and 65535.
- • Synchronization circuit to trigger the DAC.
- • Interrupt/DMA generation on the update event: counter overflow.
45.3 TIM6/TIM7 functional description
45.3.1 TIM6/TIM7 block diagram
Figure 576. Basic timer block diagram

Notes:
Reg Preload registers transferred to active registers on U event according to control bit
Event
Interrupt & DMA
MSv62381V1
45.3.2 TIM6/TIM7 internal signals
The table in this section summarizes the TIM inputs and outputs.
Table 492. TIM internal input/output signals
| Internal signal name | Signal type | Description |
|---|---|---|
| tim_pclk | Input | Timer APB clock |
| tim_ker_ck | Input | Timer kernel clock. This clock must be synchronous with tim_pclk (derived from the same source). The clock ratio tim_ker_ck/tim_pclk must be an integer: 1, 2, 3,..., 16 (maximum value) |
| tim_trgo | Output | Internal trigger output. This trigger can trigger other on-chip peripherals (DAC). |
| tim_upd_it | Output | Timer update event interrupt |
| tim_upd_dma | Output | Timer update dma request |
45.3.3 TIM6/TIM7 clocks
The timer bus interface is clocked by the tim_pclk APB clock.
The counter clock tim_ker_ck is connected to the tim_pclk input.
The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock tim_ker_ck.
Figure 577 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.
Figure 577. Control circuit in normal mode, internal clock divided by 1

The diagram illustrates the timing relationship between various signals in normal mode without a prescaler. The tim_ker_ck signal is a continuous square wave. The CEN signal is a high-level pulse that enables the counter. The UG signal is a high-level pulse that triggers an update event. The counter initialization (internal) signal is a high-level pulse that occurs when the counter is initialized. The tim_cnt_ck, tim_psc_ck signal is a square wave that is clocked by tim_ker_ck and is divided by 1. The Counter register shows the state of the counter bits (31 to 07) over time, with the counter incrementing on each rising edge of tim_cnt_ck, tim_psc_ck.
45.3.4 Time-base unit
The main block of the programmable timer is a 16-bit upcounter with its related autoreload register. The counter clock can be divided by a prescaler.
The counter, the autoreload register and the prescaler register can be written or read by software. This is true even when the counter is running.
The time-base unit includes:
- • Counter register (
TIMx_CNT) - • Prescaler register (
TIMx_PSC) - • Auto-Reload register (
TIMx_ARR).
The autoreload register is preloaded. The preload register is accessed each time an attempt is made to write or read the autoreload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the autoreload preload enable bit (ARPE) in the TIMx_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.
The counter is clocked by the prescaler output tim_cnt_ck, which is enabled only when the counter enable bit (CEN) in the TIMx_CR1 register is set.
Note that the actual counter enable signal tim_cnt_en is set one clock cycle after CEN bit set.
Prescaler description
The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as the TIMx_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.
Figure 578 and Figure 579 give some examples of the counter behavior when the prescaler ratio is changed on the fly.
Figure 578. Counter timing diagram with prescaler division change from 1 to 2

MSv50998V1
Figure 579. Counter timing diagram with prescaler division change from 1 to 4

The diagram illustrates the timing of a prescaler division change from 1 to 4. It shows the following signals and registers over time:
- tim_psc_ck: The prescaler clock signal, shown as a continuous square wave.
- CEN: The counter enable signal, which is high during the active period.
- tim_cnt_ck: The counter clock signal, derived from tim_psc_ck. Its frequency changes when the prescaler division is updated.
- Counter register: Shows the counter values. Before the update, it counts from F7 to FC. After the update, it restarts at 00 and then reaches 01.
- Update event (UEV): A pulse occurs at the end of the counter register update (after FC).
- Prescaler control register: Shows the value 0 before the update and 3 after the update. An arrow points to the write operation labeled "Write a new value in TIMx_PSC".
- Prescaler buffer: Shows the value 0 before the update and 3 after the update.
- Prescaler counter: Shows the prescaler counter values. Before the update, it is 0. After the update, it counts from 0 to 3, then restarts at 0 and counts to 3 again.
MSv50999V1
45.3.5 Counting mode
The counter counts from 0 to the autoreload value (contents of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.
An update event can be generated at each counter overflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller).
The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been written to 0, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIMx_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).
When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIMx_SR register) is set (depending on the URS bit):
- • The buffer of the prescaler is reloaded with the preload value (contents of the TIMx_PSC register).
- • The autoreload shadow register is updated with the preload value (TIMx_ARR).
The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.
Figure 580. Counter timing diagram, internal clock divided by 1

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The tim_psc_ck signal is a continuous square wave. The CEN signal is a low-to-high pulse that enables the counter. The tim_cnt_ck signal is a square wave with the same frequency as tim_psc_ck, starting after the CEN signal goes high. The Counter register shows the count sequence: it starts at 31, increments to 32, 33, 34, 35, 36, then wraps around to 00, 01, 02, 03, 04, 05, 06, 07. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 07 back to 00. The Update event (UEV) pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 36 to 00. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse. Vertical dashed lines indicate the timing of the counter register updates and the overflow event. The reference code MSv50997V1 is located in the bottom right corner.
Figure 581. Counter timing diagram, internal clock divided by 2

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a continuous square wave. The CEN signal is a low-to-high pulse that enables the counter. The tim_cnt_ck signal is a square wave with half the frequency of tim_psc_ck, starting after the CEN signal goes high. The Counter register shows the count sequence: it starts at 0034, increments to 0035, 0036, then wraps around to 0000, 0001, 0002, 0003. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0003 back to 0000. The Update event (UEV) pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0036 to 0000. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse. Vertical dashed lines indicate the timing of the counter register updates and the overflow event. The reference code MSv62300V1 is located in the bottom right corner.
Figure 582. Counter timing diagram, internal clock divided by 4

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a continuous high-frequency square wave. The CEN (Counter Enable) signal is high for the first two periods of tim_psc_ck, then low for two periods, and high again. The tim_cnt_ck (Counter Clock) signal is a divided-down version of tim_psc_ck, with one pulse for every four pulses of tim_psc_ck. The Counter register shows the count value: it increments from 0035 to 0036 on the first tim_cnt_ck pulse, then wraps to 0000 on the second tim_cnt_ck pulse (causing a Counter overflow and Update event (UEV)), and increments to 0001 on the third tim_cnt_ck pulse. The Update interrupt flag (UIF) is set high following the UEV. MSv62301V1
Figure 583. Counter timing diagram, internal clock divided by N

This timing diagram shows the counter operation with an internal clock divided by an arbitrary factor N. The tim_psc_ck signal is a square wave. The tim_cnt_ck signal has a longer period, with one pulse for every N pulses of tim_psc_ck. The Counter register shows the count value: it increments from 1F to 20 on the first tim_cnt_ck pulse, then wraps to 00 on the second tim_cnt_ck pulse (causing a Counter overflow and Update event (UEV)). The Update interrupt flag (UIF) is set high following the UEV. MSv62302V1
Figure 584. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded)

The diagram illustrates the timing of a counter update event when ARPE = 0. The counter register is 36 bits wide, with bits 31-36 and 00-07 explicitly shown. The counter overflow occurs when the counter reaches 36, triggering the update event (UEV) and the update interrupt flag (UIF). The auto-reload preload register is shown with a value of FF, and a note indicates that a new value can be written to TIMx_ARR.
| Signal | Value / State |
|---|---|
| tim_psc_ck | Periodic clock signal |
| CEN | Counter enable signal |
| tim_cnt_ck | Counter clock signal |
| Counter register | 31 | 32 33 34 35 36 | 00 01 02 03 04 05 06 07 |
| Counter overflow | Active low pulse at bit 36 |
| Update event (UEV) | Active low pulse at bit 36 |
| Update interrupt flag (UIF) | Active low pulse at bit 36 |
| Auto-reload preload register | FF | 36 |
Write a new value in TIMx_ARR
MSv62303V1
Figure 585. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded)

The diagram illustrates the timing of a counter when ARPE = 1. The counter register values are shown as a sequence of boxes: F0, F1, F2, F3, F4, F5, 00, 01, 02, 03, 04, 05, 06, 07. The counter overflow occurs at the end of the F5 box. The update event (UEV) occurs at the end of the 00 box. The update interrupt flag (UIF) is set at the end of the 00 box. The auto-reload preload register is shown as a box containing F5, and the auto-reload shadow register is shown as a box containing F5. A vertical dashed line indicates the point where a new value is written to TIMx_ARR. The counter register values are shown as a sequence of boxes: F0, F1, F2, F3, F4, F5, 00, 01, 02, 03, 04, 05, 06, 07. The counter overflow occurs at the end of the F5 box. The update event (UEV) occurs at the end of the 00 box. The update interrupt flag (UIF) is set at the end of the 00 box. The auto-reload preload register is shown as a box containing F5, and the auto-reload shadow register is shown as a box containing F5. A vertical dashed line indicates the point where a new value is written to TIMx_ARR.
Dithering mode
The time base effective resolution can be increased by enabling the dithering mode, using the DITHER bit in the TIMx_CR1 register. This affects the way the TIMx_ARR is behaving, and is useful for adjusting the average counter period when the timer is used as a trigger (typically for a DAC).
The operating principle is to have the actual ARR value slightly changed (adding or not one timer clock period) over 16 consecutive counting periods, with predefined patterns. This allows a 16-fold resolution increase, considering the average counting period.
Figure 586 presents the dithering principle applied to four consecutive counting periods.

Figure 586. Dithering principle
MSv47466V1
When the dithering mode is enabled, the register coding is changed as follows (see Figure 587 for example):
- • The four LSBs are coding for the enhanced resolution part (fractional part).
- • The MSBs are left-shifted to the bits 19:4 and are coding for the base value.
Note: The following sequence must be followed when resetting the DITHEN bit:
1. CEN and ARPE bits must be reset
2. The DITHEN bit must be reset
3. The CEN bit can be set (eventually with ARPE = 1).
Figure 587. Data format and register coding in dithering mode

MSv45753V2
The minimum frequency is given by the following formula:
Note: The maximum TIMx_ARR value is limited to 0xFFFEF in dithering mode (corresponds to 65534 for the integer part and 15 for the dithered part).
As shown on Figure 588, the dithering mode is used to increase the PWM resolution whatever the PWM frequency.
Figure 588. FCnt resolution vs frequency

MSv50910V1
The period changes are spread over 16 consecutive periods, as described in Figure 589.
Figure 589. PWM dithering pattern

MSv47465V1
The autoreload and compare values increments are spread following the specific patterns described in Table 493. The dithering sequence is done to have increments distributed as evenly as possible and minimize the overall ripple.
Table 493. TIMx_ARR register change dithering pattern
| - | PWM period | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LSB value | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| 0000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0001 | +1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0010 | +1 | - | - | - | - | - | - | - | +1 | - | - | - | - | - | - | - |
| 0011 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | - | - | - | - |
| 0100 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0101 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0110 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | +1 | - | +1 | - | - | - |
| 0111 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | - | - |
| 1000 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1001 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1010 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1011 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1100 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1101 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1110 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
| 1111 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
45.3.6 UIF bit remapping
The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This is used to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (update interrupt).
There is no latency between the assertions of the UIF and UIFCPY flags.
45.3.7 ADC triggers
The timer can generate an ADC triggering event with various internal signals, such as reset, enable or compare events.
Note: The clock of the slave peripherals (such as timer, ADC) receiving the tim_trgo signal must be enabled prior to receiving events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.
45.3.8 TIM6/TIM7 DMA requests
The TIM6/TIM7 can generate a single DMA request, as shown in Table 494.
Table 494. DMA request
| DMA acronym | DMA request | Enable control bit |
|---|---|---|
| tim_upd_dma | Update | UDE |
45.3.9 Debug mode
When the microcontroller enters debug mode (Cortex-M33 core halted), the TIMx counter can either continue to work normally or be stopped.
The behavior in debug mode can be programmed with a dedicated configuration bit per timer in the Debug support (DBG) module.
For more details, refer to section Debug support (DBG).
45.3.10 TIM6/TIM7 low-power modes
Table 495. Effect of low-power modes on TIM6/TIM7
| Mode | Description |
|---|---|
| Sleep | No effect, peripheral is active. The interrupts can cause the device to exit from Sleep mode. |
| Stop | The timer operation is stopped and the register content is kept. No interrupt can be generated. |
| Standby | The timer is powered-down and must be reinitialized after exiting the Standby mode. |
45.3.11 TIM6/TIM7 interrupts
The TIM6/TIM7 can generate a single interrupt, as shown in Table 496.
Table 496. Interrupt request
| Interrupt acronym | Interrupt event | Event flag | Enable control bit | Interrupt clear method | Exit from Sleep mode | Exit from Stop and Standby mode |
|---|---|---|---|---|---|---|
| TIM6 TIM7 | Update | UIF | UIE | write 0 in UIF | Yes | No |
45.4 TIM6/TIM7 registers
Refer to Section 1.2 for a list of abbreviations used in register descriptions.
The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).
45.4.1 TIMx control register 1 (TIMx_CR1)(x = 6 to 7)
Address offset: 0x00
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | DITH EN | UIFRE MAP | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN |
| rw | rw | rw | rw | rw | rw | rw |
Bits 15:13 Reserved, must be kept at reset value.
Bit 12 DITHEN: Dithering enable
0: Dithering disabled
1: Dithering enabled
Note: The DITHEN bit can only be modified when CEN bit is reset.
Bit 11 UIFREMAP: UIF status bit remapping
0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.
Bits 10:8 Reserved, must be kept at reset value.
Bit 7 ARPE: Auto-reload preload enable
0: TIMx_ARR register is not buffered.
1: TIMx_ARR register is buffered.
Bits 6:4 Reserved, must be kept at reset value.
Bit 3 OPM: One-pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the CEN bit).
Bit 2 URS: Update request source
This bit is set and cleared by software to select the UEV event sources.
0: Any of the following events generates an update interrupt or DMA request if enabled.
These events can be:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.
Bit 1 UDIS: Update disable
This bit is set and cleared by software to enable/disable UEV event generation.
0: UEV enabled. The Update (UEV) event is generated by one of the following events:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
Buffered registers are then loaded with their preload values.
1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.
Bit 0 CEN: Counter enable
0: Counter disabled
1: Counter enabled
CEN is cleared automatically in one-pulse mode, when an update event occurs.
45.4.2 TIMx control register 2 (TIMx_CR2)(x = 6 to 7)
Address offset: 0x04
Reset value: 0x0000
| 45.4.2 | column_2 | column_3 | column_4 | column_5 | column_6 | column_7 | column_8 | column_9 | column_10 | column_11 | column_12 | column_13 | column_14 | column_15 | RM0481 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS[2:0] | Res. | Res. | Res. | Res. | ||
| rw | rw | rw | |||||||||||||
| Bits 6:4 | MMS[2:0] | : Master mode selection | |||||||||||||
| 000: Reset | - the UG bit from the TIMx_EGR register is used as a trigger output (tim_trgo). | ||||||||||||||
| 001: Enable | - the Counter enable signal, tim_cnt_en, is used as a trigger output (tim_trgo). It written. | ||||||||||||||
| 010: Update | - The update event is selected as a trigger output (tim_trgo). For instance a | ||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE rw | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE rw |
| Bit 8 | UDE : Update DMA request enable | ||||||||||||||
| Bit 0 | UIE : Update interrupt enable |
Bits 15:7 Reserved, must be kept at reset value.
Bits 6:4 MMS[2:0]: Master mode selection
These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:
000:Reset - the UG bit from the TIMx_EGR register is used as a trigger output (tim_trgo).
001:Enable - the Counter enable signal, tim_cnt_en, is used as a trigger output (tim_trgo). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated when the CEN control bit is written.
010:Update - The update event is selected as a trigger output (tim_trgo). For instance a master timer can then be used as a prescaler for a slave timer.
Note: The clock of the slave timer or the peripheral receiving the tim_trgo must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.
Bits 3:0 Reserved, must be kept at reset value.
45.4.3 TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 6 to 7)
Address offset: 0x0C
Reset value: 0x0000
Bits 15:9 Reserved, must be kept at reset value.
Bit 8 UDE: Update DMA request enable
0: Update DMA request disabled.
1: Update DMA request enabled.
Bits 7:1 Reserved, must be kept at reset value.
Bit 0 UIE: Update interrupt enable
0: Update interrupt disabled.
1: Update interrupt enabled.
45.4.4 TIMx status register (TIMx_SR)(x = 6 to 7)
Address offset: 0x10
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF |
| rc_w0 |
Bits 15:1 Reserved, must be kept at reset value.
Bit 0 UIF: Update interrupt flag
This bit is set by hardware on an update event. It is cleared by software.
0: No update occurred.
1: Update interrupt pending. This bit is set by hardware when the registers are updated:
–On counter overflow if UDIS = 0 in the TIMx_CR1 register.
–When CNT is reinitialized by software using the UG bit in the TIMx_EGR register, if
URS = 0 and UDIS = 0 in the TIMx_CR1 register.
45.4.5 TIMx event generation register (TIMx_EGR)(x = 6 to 7)
Address offset: 0x14
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG |
| w |
Bits 15:1 Reserved, must be kept at reset value.
Bit 0 UG: Update generation
This bit can be set by software, it is automatically cleared by hardware.
0: No action.
1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).
45.4.6 TIMx counter (TIMx_CNT)(x = 6 to 7)
Address offset: 0x24
Reset value: 0x0000 0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| UIF CPY | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| r | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CNT[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bit 31 UIFCPY: UIF copy
This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.
Bits 30:16 Reserved, must be kept at reset value.
Bits 15:0 CNT[15:0]: Counter value
Non-dithering mode (DITHEN = 0)
The register holds the counter value.
Dithering mode (DITHEN = 1)
The register only holds the non-dithered part in CNT[15:0]. The fractional part is not available.
45.4.7 TIMx prescaler (TIMx_PSC)(x = 6 to 7)
Address offset: 0x28
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| PSC[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 PSC[15:0]: Prescaler value
The counter clock frequency \(f_{tim\_cnt\_ck}\) is equal to \(f_{tim\_psc\_ck} / (PSC[15:0] + 1)\).
PSC contains the value to be loaded into the active prescaler register at each update event. (including when the counter is cleared through UG bit of TIMx_EGR register).
45.4.8 TIMx autoreload register (TIMx_ARR)(x = 6 to 7)
Address offset: 0x2C
Reset value: 0x0000 FFFF
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:16] | |||
| rw | rw | rw | rw | ||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| ARR[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 31:20 Reserved, must be kept at reset value.
Bits 19:0 ARR[19:0]: Auto-reload value
ARR is the value to be loaded into the actual auto-reload register.
Refer to Section 45.3.4: Time-base unit for more details about ARR update and behavior.
The counter is blocked while the auto-reload value is null.
Non-dithering mode (DITHEN = 0)
The register holds the auto-reload value in ARR[15:0]. The ARR[19:16] bits are reserved.
Dithering mode (DITHEN = 1)
The register holds the integer part in ARR[19:4]. The ARR[3:0] bitfield contains the dithered part.
45.4.9 TIMx register map
TIMx registers are mapped as 16-bit addressable registers as described in the table below:
Table 497. TIMx register map and reset values
| Offset | Register name | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0x00 | TIMx_CR1 | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | DITHEN | UIFREMA | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN |
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||
| 0x04 | TIMx_CR2 | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS [2:0] | Res. | Res. | Res. | Res. | ||
| Reset value | 0 | 0 | 0 | ||||||||||||||||||||||||||||||
| 0x08 | Reserved | ||||||||||||||||||||||||||||||||
| 0x0C | TIMx_DIER | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE |
| Reset value | 0 | 0 | |||||||||||||||||||||||||||||||
| 0x10 | TIMx_SR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF |
| Reset value | 0 | ||||||||||||||||||||||||||||||||
| 0x14 | TIMx_EGR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG |
| Reset value | 0 | ||||||||||||||||||||||||||||||||
| 0x18-0x20 | Reserved | ||||||||||||||||||||||||||||||||
| 0x24 | TIMx_CNT | UIFCPY or Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | CNT[15:0] | |||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||
| 0x28 | TIMx_PSC | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | PSC[15:0] | ||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||
| 0x2C | TIMx_ARR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:0] | |||||||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||||||||||||
Refer to Section 2.3: Memory organization for the register boundary addresses.