28. Basic timers (TIM6/TIM7)
28.1 TIM6/TIM7 introduction
The basic timers TIM6/TIM7 consist in a 16-bit autoreload counter driven by a programmable prescaler.
They can be used as generic timers for time-base generation.
The basic timer can also be used for triggering the digital-to-analog converter. This is done with the trigger output of the timer.
The timers are completely independent, and do not share any resources.
28.2 TIM6/TIM7 main features
Basic timer (TIM6/TIM7) features include:
- • 16-bit autoreload upcounter.
- • 16-bit programmable prescaler used to divide (also “on the fly”) the counter clock frequency by any factor between 1 and 65535.
- • Synchronization circuit to trigger the DAC.
- • Interrupt/DMA generation on the update event: counter overflow.
28.3 TIM6/TIM7 functional description
28.3.1 TIM6/TIM7 block diagram
Figure 333. Basic timer block diagram
Notes:
Reg Preload registers transferred to active registers on U event according to control bit
Event
Interrupt & DMA
MSv62381V1
28.3.2 TIM6/TIM7 internal signals
The table in this section summarizes the TIM inputs and outputs.
Table 205. TIM internal input/output signals| Internal signal name | Signal type | Description |
|---|---|---|
| tim_pclk | Input | Timer APB clock |
| tim_ker_ck | Input | Timer kernel clock. This clock must be synchronous with tim_pclk (derived from the same source). The clock ratio tim_ker_ck/tim_pclk must be an integer: 1, 2, 3,..., 16 (maximum value) |
| tim_trgo | Output | Internal trigger output. This trigger can trigger other on-chip peripherals (DAC). |
| tim_upd_it | Output | Timer update event interrupt |
| tim_upd_dma | Output | Timer update dma request |
28.3.3 TIM6/TIM7 clocks
The timer bus interface is clocked by the tim_pclk APB clock.
The counter clock tim_ker_ck is connected to the tim_pclk input.
The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock tim_ker_ck.
Figure 334 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.
Figure 334. Control circuit in normal mode, internal clock divided by 1

The figure is a timing diagram illustrating the control circuit and upcounter behavior in normal mode without a prescaler. It shows the following signals over time:
- tim_ker_ck: A continuous square wave representing the timer kernel clock.
- CEN: A control signal that transitions from low to high, enabling the timer.
- UG: A control signal that transitions from low to high, triggering an update event.
- counter initialization (internal): A signal that transitions from low to high, indicating the start of counter initialization.
- tim_cnt_ck, tim_psc_ck: A square wave representing the counter and prescaler clock, which is derived from tim_ker_ck.
- Counter register: A 16-bit register shown as a sequence of bits. The bits are labeled 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07. The diagram shows the counter incrementing from 31 to 32, then 33, 34, 35, 36, and then wrapping around to 00, 01, 02, 03, 04, 05, 06, 07.
Vertical dashed lines indicate the timing of the UG and counter initialization signals relative to the clock edges. The label MSv62317V2 is located at the bottom right of the diagram.
28.3.4 Time-base unit
The main block of the programmable timer is a 16-bit upcounter with its related autoreload register. The counter clock can be divided by a prescaler.
The counter, the autoreload register and the prescaler register can be written or read by software. This is true even when the counter is running.
The time-base unit includes:
- • Counter register (TIMx_CNT)
- • Prescaler register (TIMx_PSC)
- • Auto-Reload register (TIMx_ARR).
The autoreload register is preloaded. The preload register is accessed each time an attempt is made to write or read the autoreload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the autoreload preload enable bit (ARPE) in the TIMx_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.
The counter is clocked by the prescaler output tim_cnt_ck, which is enabled only when the counter enable bit (CEN) in the TIMx_CR1 register is set.
Note that the actual counter enable signal tim_cnt_en is set one clock cycle after CEN bit set.
Prescaler description
The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as the TIMx_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.
Figure 335 and Figure 336 give some examples of the counter behavior when the prescaler ratio is changed on the fly.
Figure 335. Counter timing diagram with prescaler division change from 1 to 2

The diagram illustrates the timing of a prescaler division change from 1 to 2. It shows the following signals and registers over time:
- tim_psc_ck: Prescaler clock signal.
- CEN: Counter enable signal, which starts low and transitions high.
- tim_cnt_ck: Counter clock signal, which starts low and transitions high after CEN is set.
- Counter register: Shows the counter value. It increments from F7 to FC, then wraps around to 00, 01, 02, 03.
- Update event (UEV): A pulse that occurs when the counter reaches its maximum value (FC) and wraps around.
- Prescaler control register: Shows the value 0 before the update event and 1 after the update event. An arrow points to the transition with the text "Write a new value in TIMx_PSC".
- Prescaler buffer: Shows the value 0 before the update event and 1 after the update event.
- Prescaler counter: Shows the prescaler counter value. It increments from 0 to 1, then wraps around to 0, 1, 0, 1, 0, 1.
The diagram shows that the prescaler division change from 1 to 2 is effective after the next update event (UEV). The prescaler counter increments by 2 for each counter clock cycle after the update event.
MSv50998V1
Figure 336. Counter timing diagram with prescaler division change from 1 to 4

The diagram illustrates the timing of a prescaler division change from 1 to 4. It shows the following signals and registers over time:
- tim_psc_ck: The prescaler clock signal, which is continuous.
- CEN: The counter enable signal, which is high throughout the diagram.
- tim_cnt_ck: The counter clock signal, derived from tim_psc_ck. Its frequency changes when the prescaler division changes.
- Counter register: Shows the counter values. It increments from F7 to FC, then wraps to 00 and 01. The change in tim_cnt_ck frequency occurs at the transition from FC to 00.
- Update event (UEV): A pulse occurs at the transition from FC to 00 in the counter register.
- Prescaler control register: Shows the value changing from 0 to 3. An arrow points to the write operation, labeled "Write a new value in TIMx_PSC".
- Prescaler buffer: Shows the value changing from 0 to 3, synchronized with the update event.
- Prescaler counter: Shows the prescaler counter values. It increments from 0 to 3, then wraps to 0, 1, 2, 3. The change in frequency occurs at the transition from 3 to 0.
MSv50999V1
28.3.5 Counting mode
The counter counts from 0 to the autoreload value (contents of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.
An update event can be generate at each counter overflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller).
The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been written to 0, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIMx_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).
When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIMx_SR register) is set (depending on the URS bit):
- • The buffer of the prescaler is reloaded with the preload value (contents of the TIMx_PSC register).
- • The autoreload shadow register is updated with the preload value (TIMx_ARR).
The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.
Figure 337. Counter timing diagram, internal clock divided by 1

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The tim_psc_ck signal is a continuous clock. The CEN signal starts low and transitions high, enabling the counter. The tim_cnt_ck signal is a clock derived from tim_psc_ck with a division factor of 1, meaning it has the same frequency. The Counter register shows the count sequence: it starts at 31, increments to 32, 33, 34, 35, 36, and then wraps around to 00, 01, 02, 03, 04, 05, 06, 07. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 36 to 00. This overflow triggers an Update event (UEV) pulse. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse.
MSv50997V1
Figure 338. Counter timing diagram, internal clock divided by 2

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a continuous clock. The CEN signal starts low and transitions high, enabling the counter. The tim_cnt_ck signal is a clock derived from tim_psc_ck with a division factor of 2, meaning its frequency is half that of tim_psc_ck. The Counter register shows the count sequence: it starts at 0034, increments to 0035, 0036, and then wraps around to 0000, 0001, 0002, 0003. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0036 to 0000. This overflow triggers an Update event (UEV) pulse. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse.
MSv62300V1
Figure 339. Counter timing diagram, internal clock divided by 4

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a high-frequency square wave. The CEN (Counter Enable) signal is a low-active pulse that starts the counter. The tim_cnt_ck signal shows the divided clock, with one pulse occurring every four cycles of tim_psc_ck. The Counter register shows the count values: it starts at 0035, increments to 0036, then wraps to 0000 and increments to 0001. A Counter overflow pulse occurs when the counter wraps from 0036 to 0000. The Update event (UEV) and Update interrupt flag (UIF) signals are generated on the rising edge of the counter overflow.
MSv62301V1
Figure 340. Counter timing diagram, internal clock divided by N

This timing diagram illustrates the operation of a counter when the internal clock is divided by an arbitrary factor N. The tim_psc_ck signal is a high-frequency square wave. The tim_cnt_ck signal shows the divided clock, with one pulse occurring every N cycles of tim_psc_ck. The Counter register shows the count values: it starts at 1F, increments to 20, then wraps to 00. A Counter overflow pulse occurs when the counter wraps from 20 to 00. The Update event (UEV) and Update interrupt flag (UIF) signals are generated on the rising edge of the counter overflow.
MSv62302V1
Figure 341. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded)

The diagram illustrates the timing of an update event when ARPE = 0. The counter register is 32 bits wide, with bits 31 down to 00. The counter overflow occurs when the counter reaches 36 (0x24). The update event (UEV) is generated when the counter overflow occurs. The update interrupt flag (UIF) is set when the update event occurs. The auto-reload preload register is shown with a value of FF (0xFF) and a note indicating that a new value can be written to TIMx_ARR.
| Signal | Value / State |
|---|---|
| tim_psc_ck | Periodic clock signal |
| CEN | Counter enable signal |
| tim_cnt_ck | Counter clock signal |
| Counter register | 31 32 33 34 35 36 00 01 02 03 04 05 06 07 |
| Counter overflow | High pulse at counter value 36 |
| Update event (UEV) | High pulse at counter value 36 |
| Update interrupt flag (UIF) | High pulse at counter value 36 |
| Auto-reload preload register | FF 36 |
Write a new value in TIMx_ARR
MSv62303V1

Dithering mode
The time base effective resolution can be increased by enabling the dithering mode, using the DITHEN bit in the TIMx_CR1 register. This affects the way the TIMx_ARR is behaving, and is useful for adjusting the average counter period when the timer is used as a trigger (typically for a DAC).
The operating principle is to have the actual ARR value slightly changed (adding or not one timer clock period) over 16 consecutive counting periods, with predefined patterns. This allows a 16-fold resolution increase, considering the average counting period.
Figure 343 presents the dithering principle applied to four consecutive counting periods.

Figure 343. Dithering principle
MSv47466V1
When the dithering mode is enabled, the register coding is changed as follows (see Figure 344 for example):
- • The four LSBs are coding for the enhanced resolution part (fractional part).
- • The MSBs are left-shifted to the bits 19:4 and are coding for the base value.
Note: The following sequence must be followed when resetting the DITHEN bit:
1. CEN and ARPE bits must be reset
2. The DITHEN bit must be reset
3. The CEN bit can be set (eventually with ARPE = 1).
Figure 344. Data format and register coding in dithering mode

MSv45753V2
The minimum frequency is given by the following formula:
Note: The maximum TIMx_ARR value is limited to 0xFFFEF in dithering mode (corresponds to 65534 for the integer part and 15 for the dithered part).
As shown on Figure 345, the dithering mode is used to increase the PWM resolution whatever the PWM frequency.
Figure 345. FCnt resolution vs frequency

MSv50910V1
The period changes are spread over 16 consecutive periods, as described in Figure 346.
Figure 346. PWM dithering pattern

MSv47465V1
The autoreload and compare values increments are spread following the specific patterns described in Table 206. The dithering sequence is done to have increments distributed as evenly as possible and minimize the overall ripple.
Table 206. TIMx_ARR register change dithering pattern
| - | PWM period | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LSB value | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| 0000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0001 | +1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0010 | +1 | - | - | - | - | - | - | - | +1 | - | - | - | - | - | - | - |
| 0011 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | - | - | - | - |
| 0100 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0101 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0110 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | +1 | - | +1 | - | - | - |
| 0111 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | - | - |
| 1000 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1001 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1010 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1011 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1100 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1101 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1110 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
| 1111 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
28.3.6 UIF bit remapping
The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This is used to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (update interrupt).
There is no latency between the assertions of the UIF and UIFCPY flags.
28.3.7 ADC triggers
The timer can generate an ADC triggering event with various internal signals, such as reset, enable or compare events.
Note: The clock of the slave peripherals (such as timer, ADC) receiving the tim_trgo signal must be enabled prior to receiving events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.
28.3.8 TIM6/TIM7 DMA requests
The TIM6/TIM7 can generate a single DMA request, as shown in Table 207.
Table 207. DMA request
| DMA acronym | DMA request | Enable control bit |
|---|---|---|
| tim_upd_dma | Update | UDE |
28.3.9 Debug mode
When the microcontroller enters debug mode (Cortex-M33 core halted), the TIMx counter can either continue to work normally or be stopped.
The behavior in debug mode can be programmed with a dedicated configuration bit per timer in the Debug support (DBG) module.
For more details, refer to section Debug support (DBG).
28.3.10 TIM6/TIM7 low-power modes
Table 208. Effect of low-power modes on TIM6/TIM7
| Mode | Description |
|---|---|
| Sleep | No effect, peripheral is active. The interrupts can cause the device to exit from Sleep mode. |
| Stop | The timer operation is stopped and the register content is kept. No interrupt can be generated. |
| Standby | The timer is powered-down and must be reinitialized after exiting the Standby mode. |
28.3.11 TIM6/TIM7 interrupts
The TIM6/TIM7 can generate a single interrupt, as shown in Table 209.
Table 209. Interrupt request
| Interrupt acronym | Interrupt event | Event flag | Enable control bit | Interrupt clear method | Exit from Sleep mode | Exit from Stop and Standby mode |
|---|---|---|---|---|---|---|
| TIM6 TIM7 | Update | UIF | UIE | write 0 in UIF | Yes | No |
28.4 TIM6/TIM7 registers
Refer to Section 1.2 for a list of abbreviations used in register descriptions.
The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).
28.4.1 TIMx control register 1 (TIMx_CR1)(x = 6 to 7)
Address offset: 0x00
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | DITH EN | UIFRE MAP | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN |
| rw | rw | rw | rw | rw | rw | rw |
Bits 15:13 Reserved, must be kept at reset value.
Bit 12 DITHEN: Dithering enable
0: Dithering disabled
1: Dithering enabled
Note: The DITHEN bit can only be modified when CEN bit is reset.
Bit 11 UIFREMAP: UIF status bit remapping
0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.
Bits 10:8 Reserved, must be kept at reset value.
Bit 7 ARPE: Auto-reload preload enable
0: TIMx_ARR register is not buffered.
1: TIMx_ARR register is buffered.
Bits 6:4 Reserved, must be kept at reset value.
Bit 3 OPM: One-pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the CEN bit).
Bit 2 URS: Update request source
This bit is set and cleared by software to select the UEV event sources.
0: Any of the following events generates an update interrupt or DMA request if enabled.
These events can be:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.
Bit 1 UDIS: Update disable
This bit is set and cleared by software to enable/disable UEV event generation.
0: UEV enabled. The Update (UEV) event is generated by one of the following events:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
Buffered registers are then loaded with their preload values.
1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.
Bit 0 CEN: Counter enable
0: Counter disabled
1: Counter enabled
CEN is cleared automatically in one-pulse mode, when an update event occurs.
28.4.2 TIMx control register 2 (TIMx_CR2)(x = 6 to 7)
Address offset: 0x04
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS[2:0] | Res. | Res. | Res. | Res. | ||
| rw | rw | rw | |||||||||||||
Bits 15:7 Reserved, must be kept at reset value.
Bits 6:4 MMS[2:0]: Master mode selection
These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:
000:Reset - the UG bit from the TIMx_EGR register is used as a trigger output (tim_trgo).
001:Enable - the Counter enable signal, tim_cnt_en, is used as a trigger output (tim_trgo). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated when the CEN control bit is written.
010:Update - The update event is selected as a trigger output (tim_trgo). For instance a master timer can then be used as a prescaler for a slave timer.
Note: The clock of the slave timer or the peripheral receiving the tim_trgo must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.
Bits 3:0 Reserved, must be kept at reset value.
28.4.3 TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 6 to 7)
Address offset: 0x0C
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE |
| rw | rw |
Bits 15:9 Reserved, must be kept at reset value.
Bit 8 UDE: Update DMA request enable
0: Update DMA request disabled.
1: Update DMA request enabled.
Bits 7:1 Reserved, must be kept at reset value.
Bit 0 UIE: Update interrupt enable
0: Update interrupt disabled.
1: Update interrupt enabled.
28.4.4 TIMx status register (TIMx_SR)(x = 6 to 7)
Address offset: 0x10
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF |
| rc_w0 |
Bits 15:1 Reserved, must be kept at reset value.
Bit 0 UIF : Update interrupt flagThis bit is set by hardware on an update event. It is cleared by software.
0: No update occurred.
1: Update interrupt pending. This bit is set by hardware when the registers are updated:
–On counter overflow if UDIS = 0 in the TIMx_CR1 register.
–When CNT is reinitialized by software using the UG bit in the TIMx_EGR register, if URS = 0 and UDIS = 0 in the TIMx_CR1 register.
28.4.5 TIMx event generation register (TIMx_EGR)(x = 6 to 7)
Address offset: 0x14
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG |
| w |
Bits 15:1 Reserved, must be kept at reset value.
Bit 0 UG : Update generationThis bit can be set by software, it is automatically cleared by hardware.
0: No action.
1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).
28.4.6 TIMx counter (TIMx_CNT)(x = 6 to 7)
Address offset: 0x24
Reset value: 0x0000 0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| UIF CPY | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| r | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CNT[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bit 31 UIFCPY: UIF copy
This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.
Bits 30:16 Reserved, must be kept at reset value.
Bits 15:0 CNT[15:0]: Counter value
Non-dithering mode (DITHEN = 0)
The register holds the counter value.
Dithering mode (DITHEN = 1)
The register only holds the non-dithered part in CNT[15:0]. The fractional part is not available.
28.4.7 TIMx prescaler (TIMx_PSC)(x = 6 to 7)
Address offset: 0x28
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| PSC[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 PSC[15:0]: Prescaler value
The counter clock frequency \(f_{tim\_cnt\_ck}\) is equal to \(f_{tim\_psc\_ck} / (PSC[15:0] + 1)\).
PSC contains the value to be loaded into the active prescaler register at each update event. (including when the counter is cleared through UG bit of TIMx_EGR register).
28.4.8 TIMx autoreload register (TIMx_ARR)(x = 6 to 7)
Address offset: 0x2C
Reset value: 0x0000 FFFF
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:16] | |||
| rw | rw | rw | rw | ||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| ARR[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 31:20 Reserved, must be kept at reset value.
Bits 19:0 ARR[19:0]: Auto-reload value
ARR is the value to be loaded into the actual auto-reload register.
Refer to Section 28.3.4: Time-base unit for more details about ARR update and behavior.
The counter is blocked while the auto-reload value is null.
Non-dithering mode (DITHEN = 0)
The register holds the auto-reload value in ARR[15:0]. The ARR[19:16] bits are reserved.
Dithering mode (DITHEN = 1)
The register holds the integer part in ARR[19:4]. The ARR[3:0] bitfield contains the dithered part.
28.4.9 TIMx register map
TIMx registers are mapped as 16-bit addressable registers as described in the table below:
Table 210. TIMx register map and reset values
| Offset | Register name | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0x00 | TIMx_CR1 | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | DITHEN | UIFREMA | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN | |||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||||
| 0x04 | TIMx_CR2 | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS [2:0] | Res. | Res. | Res. | Res. | |||||
| Reset value | 0 | 0 | 0 | |||||||||||||||||||||||||||||||||
| 0x08 | Reserved | |||||||||||||||||||||||||||||||||||
| 0x0C | TIMx_DIER | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE | |||
| Reset value | 0 | 0 | ||||||||||||||||||||||||||||||||||
| 0x10 | TIMx_SR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF | |||
| Reset value | 0 | |||||||||||||||||||||||||||||||||||
| 0x14 | TIMx_EGR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG | |||
| Reset value | 0 | |||||||||||||||||||||||||||||||||||
| 0x18-0x20 | Reserved | |||||||||||||||||||||||||||||||||||
| 0x24 | TIMx_CNT | UIFCPY or Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | CNT[15:0] | ||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||
| 0x28 | TIMx_PSC | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | PSC[15:0] | |||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||
| 0x2C | TIMx_ARR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:0] | |||||||||
| Reset value | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||||||||||||||||
Refer to Section 2.2 for the register boundary addresses.