3. AHB up/down converter

The STM32WB09xE device can support several system clock frequencies from 1 MHz to 32 MHz.

The Bluetooth LE IP does not need more than 32 MHz to achieve the processing of the radio transfers while the system (CPU, DMA, memories) may require higher performance for application purpose.

To avoid useless overconsumption, AHB up/down converter block has been added to introduce an adjustable divider by one, two or four on AHB and APB bus of the MR_BLE (linked to AHBRF / APB2 bridge) versus the system bus matrix frequency. This block allows dividing by one, two or four the system clock for the MR_BLE IP of the device.

When the system and the MR_BLE share the same frequency, the AHB up/down converter block only transfers the AHB signals from one clock domain to the other.

Note: The system clock must be at 16/32 MHz and always equal or faster than MR_BLE clock when radio is used (no other frequencies).

3.1 AHB up/down converter description

The AHB up/down converter role is to allow STM32WB09xE device to support a fast system clock (up to 32 MHz).

The AHBUPCONV block manages:

Figure 3. AHB up/down converter

Block diagram of the AHB up/down converter showing the interaction between MR_BLE IP, AHB slave input, System bus matrix, and the Up/Down converter blocks.

The diagram illustrates the AHB up/down converter architecture. A vertical dashed line separates the MR_BLE domain (left) from the System bus domain (right). The MR_BLE domain operates at 16 MHz or 32 MHz and contains the MR_BLE IP (with AHB and APB interfaces) and an APB/AHB block. The System bus domain operates at 16 MHz, 32 MHz, or 64 MHz and contains the AHB slave input, System bus matrix, and AHB master output. The Up converter (1x / 2x / 4x) and Down converter (4x / 2x / 1x) are positioned on the dashed line. AHB buses connect the MR_BLE IP to the Up converter, the APB/AHB block to the Down converter, the Up converter to the AHB slave input, and the Down converter to the AHB master output. Control and Status data flow from the Up converter to the RCC and from the Down converter to the System bus matrix. The RCC also sends an interrupt to the CPU.

Block diagram of the AHB up/down converter showing the interaction between MR_BLE IP, AHB slave input, System bus matrix, and the Up/Down converter blocks.

The management of data transfer versus clock domain and possible clock switch request is done using state machines:

When a CPU/system clock frequency switch is needed (activate or deactivate the divider by two between the system and the MR_BLE), the user must request the new system clock targeted frequency in the RCC_CSCMDR.REQUEST bit (see Section 6.6.6: Clock switch command register (RCC_CSCMDR) for details).

When receiving a new divider ratio to apply (from the RCC), the AHBUPCONV block: