16. General purpose timer (TIM2)

In this section, “TIMx” refers to TIM2, since there is only one instance of this timer in the STM32WB09xE device.

16.1 TIM2 introduction

The general purpose timers (TIM2) consist of a 16-bit auto-reload counter driven by a programmable prescaler.

It may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM, complementary PWM with dead-time insertion).

Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler on the timer input clock which is at 32 MHz.

16.2 TIM2 main features

TIM2 timer features include:

Figure 26. General purpose timer block diagram

Block diagram of the General Purpose Timer (TIM2) showing internal components like the Trigger controller, Slave mode controller, Encoder interface, PSC prescaler, CNT counter, and four capture/compare channels (1-4) with their respective input filters, prescalers, and output controls.

The diagram illustrates the internal architecture of the General Purpose Timer (TIM2). It features a central CNT counter (labeled with +/-) which is clocked by CK_CNT from the PSC Prescaler. The counter's operation is managed by a Trigger controller and a Slave mode controller, which receive inputs from ETRF, TRGI, and TRC. The Trigger controller also interfaces with an Encoder interface via T11FP1 and T12FP2. External triggers include TIMx_ETR (via ETR and ETRP), ITR0-ITR3 (via ITR), and ETRF. The timer has four channels (TIMx_CH1 to TIMx_CH4). Each channel consists of an Input filter & edge detector (receiving TI1-TI4), a Prescaler (receiving IC1-IC4), a Capture/compare register (receiving CC1I-CC4I), and an output control (sending OC1-OC4). The registers are linked to the counter via CC11-CC41 and CC11REF-CC41REF signals. A Repetition counter (receiving UI) and Autoreload register (receiving U) are also shown. Control signals like Stop, clear or up/down and OCREF_CLR are included. A legend at the bottom left defines symbols for registers, events, and interrupt/DMA outputs.

Notes:

Block diagram of the General Purpose Timer (TIM2) showing internal components like the Trigger controller, Slave mode controller, Encoder interface, PSC prescaler, CNT counter, and four capture/compare channels (1-4) with their respective input filters, prescalers, and output controls.

16.3 TIM2 functional description

16.3.1 Time-base unit

The main block of the programmable general purpose timer is a 16-bit counter with its related auto-reload register. The counter can count up, down or both up and down. The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. Writing to or reading from the auto-reload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the auto-reload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow (or underflow when downcounting) and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detailed for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).

Note that the counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 27 and Figure 28 give some examples of the counter behavior when the prescaler ratio is changed on the fly:

Figure 27. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for Figure 27 showing counter timing with prescaler division change from 1 to 2. The diagram includes signals: CK_PSC (input clock), CEN (enable), Timer clock = CK_CNT (output clock), Counter register (values F7 to 03), Update event (UEV), Prescaler control register (values 0 to 1), Prescaler buffer (values 0 to 1), and Prescaler counter (values 0 to 1).

The diagram illustrates the timing of a counter when the prescaler division is changed from 1 to 2. The CK_PSC signal is a continuous square wave. The CEN signal is high during the active period. The Timer clock = CK_CNT signal is a square wave with a period of two CK_PSC cycles. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. The Update event (UEV) is a pulse at the end of the counter register. The Prescaler control register shows a transition from 0 to 1. The Prescaler buffer shows a transition from 0 to 1. The Prescaler counter shows values 0, 0, 1, 0, 1, 0, 1, 0, 1.

Timing diagram for Figure 27 showing counter timing with prescaler division change from 1 to 2. The diagram includes signals: CK_PSC (input clock), CEN (enable), Timer clock = CK_CNT (output clock), Counter register (values F7 to 03), Update event (UEV), Prescaler control register (values 0 to 1), Prescaler buffer (values 0 to 1), and Prescaler counter (values 0 to 1).

Figure 28. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for Figure 28 showing counter timing with prescaler division change from 1 to 4. The diagram includes signals: CK_PSC (input clock), CEN (enable), Timer clock = CK_CNT (output clock), Counter register (values F7 to 01), Update event (UEV), Prescaler control register (values 0 to 3), Prescaler buffer (values 0 to 3), and Prescaler counter (values 0 to 3).

The diagram illustrates the timing of a counter when the prescaler division is changed from 1 to 4. The CK_PSC signal is a continuous square wave. The CEN signal is high during the active period. The Timer clock = CK_CNT signal is a square wave with a period of four CK_PSC cycles. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. The Update event (UEV) is a pulse at the end of the counter register. The Prescaler control register shows a transition from 0 to 3. The Prescaler buffer shows a transition from 0 to 3. The Prescaler counter shows values 0, 0, 1, 2, 3, 0, 1, 2, 3.

Timing diagram for Figure 28 showing counter timing with prescaler division change from 1 to 4. The diagram includes signals: CK_PSC (input clock), CEN (enable), Timer clock = CK_CNT (output clock), Counter register (values F7 to 01), Update event (UEV), Prescaler control register (values 0 to 3), Prescaler buffer (values 0 to 3), and Prescaler counter (values 0 to 3).

16.3.2 Counter modes

Upcounting mode

In upcounting mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

If the repetition counter is used, the update event (UEV) is generated after upcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR) + 1. Else the update event is generated at each counter overflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 29. Counter timing diagram, internal clock divided by 1

Timing diagram for Figure 29 showing counter behavior with internal clock divided by 1. The diagram includes waveforms for CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values from 31 to 07, with an overflow at 36, triggering the UEV and setting the UIF flag.

The diagram illustrates the timing of various signals for a counter with an internal clock divided by 1. The signals shown are:

Timing diagram for Figure 29 showing counter behavior with internal clock divided by 1. The diagram includes waveforms for CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values from 31 to 07, with an overflow at 36, triggering the UEV and setting the UIF flag.

Figure 30. Counter timing diagram, internal clock divided by 2

Timing diagram for Figure 30 showing counter behavior with internal clock divided by 2. The diagram includes waveforms for CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values from 0034 to 0003, with an overflow at 0036, triggering the UEV and setting the UIF flag.

The diagram illustrates the timing of various signals for a counter with an internal clock divided by 2. The signals shown are:

Timing diagram for Figure 30 showing counter behavior with internal clock divided by 2. The diagram includes waveforms for CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values from 0034 to 0003, with an overflow at 0036, triggering the UEV and setting the UIF flag.

Figure 31. Counter timing diagram, internal clock divided by 4

Timing diagram for Figure 31 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then goes low. The Timer clock = CK_CNT is derived from CK_PSC and is divided by 4. The Counter register shows the sequence of values: 0035, 0036, 0000, and 0001. The Counter overflow occurs when the counter reaches 0036 and rolls over to 0000. The Update event (UEV) is generated on the rising edge of the counter overflow. The Update interrupt flag (UIF) is set on the rising edge of the UEV.

Timing diagram for Figure 31 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 32. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 32 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram shows the counter operation with an internal clock divided by an arbitrary factor N. The CK_PSC signal is a high-frequency square wave. The Timer clock = CK_CNT is derived from CK_PSC and is divided by N. The Counter register shows the sequence of values: 1F, 20, and 00. The Counter overflow occurs when the counter reaches 20 and rolls over to 00. The Update event (UEV) is generated on the rising edge of the counter overflow. The Update interrupt flag (UIF) is set on the rising edge of the UEV.

Timing diagram for Figure 32 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 33. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Timing diagram for Figure 33 showing CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload register.

This timing diagram illustrates the counter operation when the auto-reload preload enable (ARPE) is 0, meaning the TIMx_ARR register is not preloaded. The CK_PSC signal is a high-frequency square wave. The CEN signal is a low-active enable signal that starts high and then goes low. The Timer clock = CK_CNT is derived from CK_PSC and is divided by 4. The Counter register shows the sequence of values: 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07. The Counter overflow occurs when the counter reaches 36 and rolls over to 00. The Update event (UEV) is generated on the rising edge of the counter overflow. The Update interrupt flag (UIF) is set on the rising edge of the UEV. The Auto-reload register shows the value FF, which is written into the counter register. An arrow points to the transition of the Auto-reload register from FF to 36, labeled 'Write a new value in TIMx_ARR'.

Timing diagram for Figure 33 showing CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload register.

Figure 34. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Timing diagram for a counter when ARPE=1 and TIMx_ARR is preloaded. The diagram shows the following signals over time: CK_PSC (prescaler clock), CEN (counter enable), Timer clock = CK_CNT (counter clock), Counter register (showing values F0, F1, F2, F3, F4, F5, 00, 01, 02, 03, 04, 05, 06, 07), Counter overflow (pulsing high at F5), Update event (UEV) (pulsing high at F5), Update interrupt flag (UIF) (pulsing high at F5), Auto-reload preload register (value F5, then 36), and Auto-reload shadow register (value F5, then 36). A vertical line indicates 'Write a new value in TIMx_ARR' at the point where the preload and shadow registers change from F5 to 36.
Timing diagram for a counter when ARPE=1 and TIMx_ARR is preloaded. The diagram shows the following signals over time: CK_PSC (prescaler clock), CEN (counter enable), Timer clock = CK_CNT (counter clock), Counter register (showing values F0, F1, F2, F3, F4, F5, 00, 01, 02, 03, 04, 05, 06, 07), Counter overflow (pulsing high at F5), Update event (UEV) (pulsing high at F5), Update interrupt flag (UIF) (pulsing high at F5), Auto-reload preload register (value F5, then 36), and Auto-reload shadow register (value F5, then 36). A vertical line indicates 'Write a new value in TIMx_ARR' at the point where the preload and shadow registers change from F5 to 36.

Downcounting mode

In downcounting mode, the counter counts from the auto-reload value (content of the TIMx_ARR register) down to 0, then restarts from the auto-reload value and generates a counter underflow event.

If the repetition counter is used, the update event (UEV) is generated after downcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR) + 1. Else the update event is generated at each counter underflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV update event can be disabled by software by setting the UDIS bit in TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter restarts from the current auto-reload value, whereas the counter of the prescaler restarts from 0 (but the prescale rate doesn't change).

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 35. Counter timing diagram, internal clock divided by 1

Timing diagram for Figure 35 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow (cnt_udf), Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F.

Figure 35 shows the counter behavior when the internal clock is divided by 1. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then goes low. The Timer clock = CK_CNT signal is a square wave with the same frequency as CK_PSC. The Counter register shows the sequence of values: 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F. The Counter underflow (cnt_udf) signal is a low-active pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a low-active pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) signal is a low-active pulse that occurs when the counter reaches 00.

Timing diagram for Figure 35 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow (cnt_udf), Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 05, 04, 03, 02, 01, 00, 36, 35, 34, 33, 32, 31, 30, 2F.

Figure 36. Counter timing diagram, internal clock divided by 2

Timing diagram for Figure 36 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 0002, 0001, 0000, 0036, 0035, 0034, 0033.

Figure 36 shows the counter behavior when the internal clock is divided by 2. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then goes low. The Timer clock = CK_CNT signal is a square wave with half the frequency of CK_PSC. The Counter register shows the sequence of values: 0002, 0001, 0000, 0036, 0035, 0034, 0033. The Counter underflow signal is a low-active pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a low-active pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) signal is a low-active pulse that occurs when the counter reaches 00.

Timing diagram for Figure 36 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 0002, 0001, 0000, 0036, 0035, 0034, 0033.

Figure 37. Counter timing diagram, internal clock divided by 4

Timing diagram for Figure 37 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 0001, 0000, 0036, 0035.

Figure 37 shows the counter behavior when the internal clock is divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then goes low. The Timer clock = CK_CNT signal is a square wave with one-quarter the frequency of CK_PSC. The Counter register shows the sequence of values: 0001, 0000, 0036, 0035. The Counter underflow signal is a low-active pulse that occurs when the counter reaches 00. The Update event (UEV) signal is a low-active pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) signal is a low-active pulse that occurs when the counter reaches 00.

Timing diagram for Figure 37 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF) signals. The counter register shows values 0001, 0000, 0036, 0035.

Figure 38. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 38 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 38 is a timing diagram for a counter with an internal clock divided by N. It shows the following signals over time:

Timing diagram for Figure 38 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 39. Counter timing diagram, update event when repetition counter is not used

Timing diagram for Figure 39 showing CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload register.

Figure 39 is a timing diagram for a counter when the repetition counter is not used. It shows the following signals over time:

Timing diagram for Figure 39 showing CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload register.

Center-aligned mode (up/down counting)

In center-aligned mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register) – 1, generates a counter overflow event, then counts from the auto-reload value down to 1 and generates a counter underflow event. Then it restarts counting from 0.

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are not equal to '00'. The Output compare interrupt flag of channels configured in output is set when: the counter counts down (Center aligned mode 1, CMS = "01"), the counter counts up (Center aligned mode 2, CMS = "10") the counter counts up and down (Center aligned mode 3, CMS = "11").

In this mode, the DIR direction bit in the TIMx_CR1 register cannot be written. It is updated by hardware and gives the current direction of the counter.

The update event can be generated at each counter overflow and at each counter underflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event. In this case, the counter restarts counting from 0, as well as the counter of the prescaler.

The UEV update event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until UDIS bit has been written to 0. However, the counter continues counting up and down, based on the current auto-reload value.

In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an UEV update event but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies.

Figure 40. Counter timing diagram, internal clock divided by 1, TIMx_ARR = 0x6

Timing diagram for a general-purpose timer (TIM2) showing the relationship between various signals and the counter register values. The diagram includes the following signals: CK_PSC (prescaler clock), CNT_EN (counter enable), Timer clock = CK_CNT (counter clock), Counter register (showing values 04, 03, 02, 01, 00, 01, 02, 03, 04, 05, 06, 05, 04, 03), Counter underflow, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register values are shown in a sequence of boxes, indicating the count progression. The counter underflow and overflow signals are shown as pulses. The Update event (UEV) is shown as a pulse at the end of each counter period. The Update interrupt flag (UIF) is shown as a pulse at the end of each counter period.
Timing diagram for a general-purpose timer (TIM2) showing the relationship between various signals and the counter register values. The diagram includes the following signals: CK_PSC (prescaler clock), CNT_EN (counter enable), Timer clock = CK_CNT (counter clock), Counter register (showing values 04, 03, 02, 01, 00, 01, 02, 03, 04, 05, 06, 05, 04, 03), Counter underflow, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register values are shown in a sequence of boxes, indicating the count progression. The counter underflow and overflow signals are shown as pulses. The Update event (UEV) is shown as a pulse at the end of each counter period. The Update interrupt flag (UIF) is shown as a pulse at the end of each counter period.
  1. 1. Here, center-aligned mode 1 is used (for more details refer to Section 16.4: TIM2 registers).

Figure 41. Counter timing diagram, internal clock divided by 2

Timing diagram for Figure 41 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF). The counter register counts down from 0003 to 0000 and then wraps to 0001, 0002, 0003.

The diagram shows the following signals over time:

Timing diagram for Figure 41 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF). The counter register counts down from 0003 to 0000 and then wraps to 0001, 0002, 0003.

Figure 42. Counter timing diagram, internal clock divided by 4, TIMx_ARR=0x36

Timing diagram for Figure 42 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register counts from 0034 to 0036 and wraps to 0035.

The diagram shows the following signals over time:

Note: Here, center-aligned mode 2 or 3 is used with an UIF on overflow

Timing diagram for Figure 42 showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). The counter register counts from 0034 to 0036 and wraps to 0035.

Figure 43. Counter timing diagram, internal clock divided by N

Timing diagram for Figure 43 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values 20, 1F, 01, 00.

The diagram shows the following signals over time:

Timing diagram for Figure 43 showing CK_PSC, Timer clock = CK_CNT, Counter register, Counter underflow, Update event (UEV), and Update interrupt flag (UIF). The counter register shows values 20, 1F, 01, 00.

Figure 44. Counter timing diagram, update event with ARPE=1 (counter underflow)

Timing diagram for counter underflow (Figure 44).

The diagram shows the following signals over time:

Timing diagram for counter underflow (Figure 44).

Figure 45. Counter timing diagram, Update event with ARPE=1 (counter overflow)

Timing diagram for counter overflow (Figure 45).

The diagram shows the following signals over time:

Timing diagram for counter overflow (Figure 45).

16.3.3 Repetition counter

Section 16.3.1: Time-base unit describes how the update event (UEV) is generated with respect to the counter overflows/underflows. It is actually generated only when the repetition counter has reached zero. This can be useful when generating PWM signals.

This means that data are transferred from the preload registers to the shadow registers (TIMx_ARR auto-reload register, TIMx_PSC prescaler register, but also TIMx_CCRx capture/compare registers in compare mode) every N+1 counter overflows or underflows, where N is the value in the TIMx_RCR repetition counter register.

The repetition counter is decremented:

The repetition counter is an auto-reload type; the repetition rate is maintained as defined by the TIMx_RCR register value (refer to Figure 46). When the update event is generated by software (by setting the UG bit in TIMx_EGR register) or by hardware through the slave mode controller, it occurs immediately whatever the value of the repetition counter is and the repetition counter is reloaded with the content of the TIMx_RCR register.

In Center aligned mode, for odd values of RCR, the update event occurs either on the overflow or on the underflow depending on when the RCR register was written and when the counter was launched: if the RCR was written before launching the counter, the UEV occurs on the overflow. If the RCR was written after launching the counter, the UEV occurs on the underflow.

For example, for RCR = 3, the UEV is generated each 4th overflow or underflow event depending on when the RCR was written.

Figure 46. Update rate examples depending on mode and TIMx_RCR register settings

Figure 46: Update rate examples depending on mode and TIMx_RCR register settings. The diagram shows three columns: Center-aligned mode, Edge-aligned mode (Upcounting), and Edge-aligned mode (Downcounting). Each column displays waveforms for Counter TIMx_CNT and Update Events (UEV) for various TIMx_RCR values (0, 1, 2, 3). A re-synchronization example is shown for RCR=3. A legend explains the symbols for Update Events.

The figure illustrates the update event (UEV) generation for different TIMx_RCR settings across three modes: Center-aligned, Edge-aligned (Upcounting), and Edge-aligned (Downcounting). The Counter TIMx_CNT is shown as a sawtooth waveform, and the UEV is indicated by arrows.

Legend:

Figure 46: Update rate examples depending on mode and TIMx_RCR register settings. The diagram shows three columns: Center-aligned mode, Edge-aligned mode (Upcounting), and Edge-aligned mode (Downcounting). Each column displays waveforms for Counter TIMx_CNT and Update Events (UEV) for various TIMx_RCR values (0, 1, 2, 3). A re-synchronization example is shown for RCR=3. A legend explains the symbols for Update Events.

16.3.4 External trigger input

The timer features an external trigger input ETR. It can be used as:

The Figure 47 below describes the ETR input conditioning. The input polarity is defined with the ETP bit in TIMx_SMCR register. The trigger can be prescaled with the divider programmed by the ETPS[1:0] bitfield and digitally filtered with the ETF[3:0] bit field.

Figure 47. External trigger input block

Block diagram of the external trigger input conditioning circuit. The ETR input is split into a direct path and an inverted path (via a NOT gate) to a multiplexer. The multiplexer is controlled by the ETP bit in the TIMx_SMCR register. The output of the multiplexer goes to a divider block (controlled by ETPS[1:0] in TIMx_SMCR) which outputs ETRP and CK_INT. CK_INT goes to a filter/downcounter block (controlled by ETF[3:0] in TIMx_SMCR). The output of this block goes to a mode selection block. This block has four inputs: TI2F or TI1F (encoder mode), TRGI (external clock mode 1), ETRF (external clock mode 2), and CK_INT (internal clock mode). The mode selection is controlled by ECE and SMS[2:0] bits in the TIMx_SMCR register. The final output is CK_PSC.
Block diagram of the external trigger input conditioning circuit. The ETR input is split into a direct path and an inverted path (via a NOT gate) to a multiplexer. The multiplexer is controlled by the ETP bit in the TIMx_SMCR register. The output of the multiplexer goes to a divider block (controlled by ETPS[1:0] in TIMx_SMCR) which outputs ETRP and CK_INT. CK_INT goes to a filter/downcounter block (controlled by ETF[3:0] in TIMx_SMCR). The output of this block goes to a mode selection block. This block has four inputs: TI2F or TI1F (encoder mode), TRGI (external clock mode 1), ETRF (external clock mode 2), and CK_INT (internal clock mode). The mode selection is controlled by ECE and SMS[2:0] bits in the TIMx_SMCR register. The final output is CK_PSC.

The ETR input comes from input pins (see Table 7: Alternate modes 0, 1 and 2 and Table 8: Alternate modes 3, 4, and 6).

16.3.5 Clock selection

The counter clock can be provided by the following clock sources:

Note: Only channel 1 and channel 2 support the external clock mode 1.

Internal clock source (CK_INT)

If the slave mode controller is disabled (SMS=000), then the CEN, DIR (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except UG which remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 48 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 48. Control circuit in normal mode, internal clock divided by 1

Timing diagram for Figure 48 showing the relationship between Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock, and Counter register.

The diagram shows the following signals over time:

Timing diagram for Figure 48 showing the relationship between Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock, and Counter register.

External clock source mode 1

This mode is selected when SMS=111 in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.

Figure 49. TI2 external clock connection example

Block diagram of the TI2 external clock connection example.

The diagram illustrates the signal flow for external clock mode 1:

Block diagram of the TI2 external clock connection example.

For example, to configure the upcounter to count in response to a rising edge on the TI2 input, use the following procedure:

  1. 1. Select the proper TI2x source (internal or external) with the TI2SEL[3:0] bits in the TIMx_TISEL register.
  2. 2. Configure channel 2 to detect rising edges on the TI2 input by writing CC2S = '01' in the TIMx_CCMR1 register.
  3. 3. Configure the input filter duration by writing the IC2F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC2F=0000).
  4. 4. Select rising edge polarity by writing CC2P=0 and CC2NP=0 in the TIMx_CCER register.
  5. 5. Configure the timer in external clock mode 1 by writing SMS=111 in the TIMx_SMCR register.
  6. 6. Select TI2 as the trigger input source by writing TS=110 in the TIMx_SMCR register.
  7. 7. Enable the counter by writing CEN=1 in the TIMx_CR1 register.

Note: The capture prescaler is not used for triggering, so you don't need to configure it.

When a rising edge occurs on TI2, the counter counts once and the TIF flag is set.

The delay between the rising edge on TI2 and the actual clock of the counter is due to the resynchronization circuit on TI2 input.

Figure 50. Control circuit in external clock mode 1

Timing diagram for Figure 50 showing the relationship between TI2, CNT_EN, Counter clock, Counter register, and TIF signals.

The diagram shows the following signals over time:

Timing diagram for Figure 50 showing the relationship between TI2, CNT_EN, Counter clock, Counter register, and TIF signals.

External clock source mode 2

This mode is selected by writing ECE=1 in the TIMx_SMCR register.

The counter can count at each rising or falling edge on the external trigger input ETR.

The Figure 51 gives an overview of the external trigger input block.

Figure 51. External trigger input block

Block diagram of the external trigger input block showing the signal flow from ETR input to CK_PSC.

The diagram illustrates the signal flow through the external trigger input block:

Block diagram of the external trigger input block showing the signal flow from ETR input to CK_PSC.

For example, to configure the upcounter to count each 2 rising edges on ETR, use the following procedure:

  1. 1. As no filter is needed in this example, write ETF[3:0]=0000 in the TIMx_SMCR register.
  2. 2. Set the prescaler by writing ETPS[1:0]=01 in the TIMx_SMCR register
  3. 3. Select rising edge detection on the ETR pin by writing ETP=0 in the TIMx_SMCR register
  4. 4. Enable external clock mode 2 by writing ECE=1 in the TIMx_SMCR register.
  5. 5. Enable the counter by writing CEN=1 in the TIMx_CR1 register.

The counter counts once each 2 ETR rising edges.

The delay between the rising edge on ETR and the actual clock of the counter is due to the resynchronization circuit on the ETRP signal.

Figure 52. Control circuit in external clock mode 2

Timing diagram for Figure 52 showing signals fCK_INT, CNT_EN, ETR, ETRP, ETRF, Counter clock, and Counter register values over three cycles.

The diagram shows the timing relationship between several signals in external clock mode 2.
- fCK_INT: The primary system clock, shown as a continuous square wave.
- CNT_EN: Counter enable signal, which is high for the first two cycles and low for the third.
- ETR: External Trigger input, a square wave that is high during the first and third cycles.
- ETRP: External Trigger Polarity, a square wave that is high during the second and third cycles.
- ETRF: External Trigger Filter, a filtered version of ETRP, shown as a single-pulse signal.
- Counter clock = CK_CNT = CK_PSC: The clock used by the counter, which is fCK_INT when ETRP is high and ETRF when ETRP is low.
- Counter register: Shows the counter value at the end of each cycle: 34, 35, and 36.

Timing diagram for Figure 52 showing signals fCK_INT, CNT_EN, ETR, ETRP, ETRF, Counter clock, and Counter register values over three cycles.

16.3.6 Capture/compare channels

Each Capture/Compare channel is built around a capture/compare register (including a shadow register), an input stage for capture (with digital filter, multiplexing, and prescaler, except for channels 5 and 6) and an output stage (with comparator and output control).

Figure 53 to Figure 55 give an overview of one Capture/Compare channel.

The input stage samples the corresponding TIx input to generate a filtered signal TIxF. Then, an edge detector with polarity selection generates a signal (TIxFPx) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).

Figure 53. Capture/compare channel (example: channel 1 input stage)

Block diagram of the capture/compare channel 1 input stage, showing the flow from TI1 input through filtering, edge detection, polarity selection, and prescaling to the capture register.

This block diagram illustrates the input stage for capture/compare channel 1.
- TI1: The raw input signal.
- filter downcounter: A digital filter controlled by ICF[3:0] from TIMx_CCMR1.
- TI1F: The filtered signal output from the filter.
- Edge Detector: Detects edges on TI1F, outputting TI1F_Rising and TI1F_Falling.
- TI1F_ED: An OR of the rising and falling edges, sent to the slave mode controller.
- TI1FP1: The polarity-selected edge signal, selected by a multiplexer (0 for rising, 1 for falling) controlled by CC1P/CC1NP from TIMx_CCER.
- TI2FP1: A similar polarity-selected signal from channel 2, selected by a multiplexer (0 for rising, 1 for falling) controlled by TI2F_rising and TI2F_falling from TIMx_CCMR1.
- TRC: Trigger control signal from the slave mode controller, selecting between TI1FP1 and TI2FP1 via a multiplexer.
- IC1: The selected edge signal, controlled by CC1S[1:0] from TIMx_CCMR1.
- divider /1, /2, /4, /8: A prescaler controlled by ICPS[1:0] from TIMx_CCMR1.
- IC1PS: The final prescaled edge signal sent to the capture/compare register, controlled by CC1E from TIMx_CCER.

Block diagram of the capture/compare channel 1 input stage, showing the flow from TI1 input through filtering, edge detection, polarity selection, and prescaling to the capture register.

The output stage generates an intermediate waveform which is then used for reference: OCxRef (active high). The polarity acts at the end of the chain.

Figure 54. Capture/compare channel 1 main circuit

Figure 54: Capture/compare channel 1 main circuit diagram. The diagram shows the internal logic of channel 1, including the APB Bus, MCU-peripheral interface, Capture/compare preload register, Capture/compare shadow register, Counter, and Comparator. It details the flow of data between registers and the logic for capturing and comparing values. Key signals include read CCR1H/L, write CCR1H/L, CC1S[1:0], IC1PS, CC1E, CC1G, TIMx_EGR, and OC1PE. The preload register is accessed via the APB Bus, while the shadow register is used for capture and compare operations. The counter feeds into a comparator that generates CNT>CCR1 and CNT=CCR1 signals.
Figure 54: Capture/compare channel 1 main circuit diagram. The diagram shows the internal logic of channel 1, including the APB Bus, MCU-peripheral interface, Capture/compare preload register, Capture/compare shadow register, Counter, and Comparator. It details the flow of data between registers and the logic for capturing and comparing values. Key signals include read CCR1H/L, write CCR1H/L, CC1S[1:0], IC1PS, CC1E, CC1G, TIMx_EGR, and OC1PE. The preload register is accessed via the APB Bus, while the shadow register is used for capture and compare operations. The counter feeds into a comparator that generates CNT>CCR1 and CNT=CCR1 signals.

Figure 55. Output stage of capture/compare channel (channels 4,3,2,1)

Figure 55: Output stage of capture/compare channel (channels 4,3,2,1) diagram. This diagram illustrates the output logic for channels 4, 3, 2, and 1. It includes the TIMx_SMCR (OCCS), OCREF_CLR, ETRF, and ocref_clr_int signals. The output mode controller uses CNT > CCR4 and CNT = CCR4 to control the output. The output selector chooses between OC4REF and OC3REF based on OC4M[3:0] from TIMx_CCMR2. The output enable circuit, controlled by CC4E and CC4P from TIMx_CCER, produces the final OC4 output. A signal 'To the master mode controller' is also shown.
Figure 55: Output stage of capture/compare channel (channels 4,3,2,1) diagram. This diagram illustrates the output logic for channels 4, 3, 2, and 1. It includes the TIMx_SMCR (OCCS), OCREF_CLR, ETRF, and ocref_clr_int signals. The output mode controller uses CNT > CCR4 and CNT = CCR4 to control the output. The output selector chooses between OC4REF and OC3REF based on OC4M[3:0] from TIMx_CCMR2. The output enable circuit, controlled by CC4E and CC4P from TIMx_CCER, produces the final OC4 output. A signal 'To the master mode controller' is also shown.

The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.

In capture mode, captures are actually done in the shadow register, which is copied into the preload register.

In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.

16.3.7 Input capture mode

In Input capture mode, the Capture/Compare Registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCxIF flag was already high, then the over-capture flag CCxOF (TIMx_SR register) is set. CCxIF can be cleared by software by writing it to '0' or by reading the captured data stored in the TIMx_CCRx register. CCxOF is cleared when you write it to '0'.

The following example shows how to capture the counter value in TIMx_CCR1 when TI1 input rises. To do this, use the following procedure:

When an input capture occurs:

In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which could happen after reading the flag and before reading the data.

Note: IC interrupt and/or DMA requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.

16.3.8 PWM input mode

Note: Only channel 1 and channel 2 support this PWM input mode.

This mode is a particular case of input capture mode. The procedure is the same except:

For example, you can measure the period (in TIMx_CCR1 register) and the duty cycle (in TIMx_CCR2 register) of the PWM applied on TI1 using the following procedure (depending on CK_INT frequency and prescaler value):

Figure 56. PWM input mode timing

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, and TIMx_CCR1/CCR2 registers. It illustrates three capture events: IC1 capture/IC2 capture/reset counter, IC2 capture/pulse width measurement, and IC1 capture/period measurement.

The diagram illustrates the timing of PWM input mode captures. It shows four horizontal axes: TI1 (input signal), TIMx_CNT (counter), TIMx_CCR1 (capture/compare register 1), and TIMx_CCR2 (capture/compare register 2). The TI1 signal is a PWM waveform. The TIMx_CNT counter increments from 0004 to 0000, then 0001, 0002, 0003, 0004, and back to 0000. The TIMx_CCR1 register holds the value 0004, and the TIMx_CCR2 register holds the value 0002. Three capture events are marked with arrows: 1. At the first rising edge of TI1, an arrow points to the text 'IC1 capture IC2 capture reset counter'. 2. At the first falling edge of TI1, an arrow points to the text 'IC2 capture pulse width measurement'. 3. At the second rising edge of TI1, an arrow points to the text 'IC1 capture period measurement'. The reference code 'ai15413' is located at the bottom right of the diagram area.

Timing diagram for PWM input mode showing TI1 signal, TIMx_CNT counter, and TIMx_CCR1/CCR2 registers. It illustrates three capture events: IC1 capture/IC2 capture/reset counter, IC2 capture/pulse width measurement, and IC1 capture/period measurement.

16.3.9 Forced output mode

In output mode (CCxS bits = 00 in the TIMx_CCMRx register), each output compare signal (OCxREF and then OCx/OCxN) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.

To force an output compare signal (OCXREF/OCx) to its active level, you just need to write 0101 in the OCxM bits in the corresponding TIMx_CCMRx register. Thus OCXREF is forced high (OCxREF is always active high) and OCx get opposite value to CCxP polarity bit.

For example: CCxP=0 (OCx active high) => OCx is forced to high level.

The OCxREF signal can be forced low by writing the OCxM bits to 0100 in the TIMx_CCMRx register.

Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt and DMA requests can be sent accordingly. This is described in the output compare mode section below.

16.3.10 Output compare mode

This function is used to control an output waveform or indicate when a period of time has elapsed. Channels 1 to 6 can be output.

When a match is found between the capture/compare register and the counter, the output compare function:

The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.

In output compare mode, the update event UEV has no effect on OCxREF and OCx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One Pulse mode).

Procedure:

  1. 1. Select the counter clock (internal, external, prescaler).
  2. 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
  3. 3. Set the CCxIE bit if an interrupt request is to be generated.
  4. 4. Select the output mode. For example:
    • – Write OCxM = 0011 to toggle OCx output pin when CNT matches CCRx
    • – Write OCxPE = 0 to disable preload register
    • – Write CCxP = 0 to select active high polarity
    • – Write CCxE = 1 to enable the output
  5. 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.

The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE='0', else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 57.

Figure 57. Output compare mode, toggle on OC1

Timing diagram for output compare mode, toggle on OC1. It shows three signals: TIM2_CNT, TIM2_CCR1, and oc1ref=OC1. TIM2_CNT increments from 0039 to 003A, then 003B, and eventually reaches B201. TIM2_CCR1 is initially 003A and is updated to B201 after a write operation. The oc1ref=OC1 signal toggles its state at each match between TIM2_CNT and TIM2_CCR1. A write operation to the CC1R register with value B201h is shown, which updates the TIM2_CCR1 register. The match between TIM2_CNT and TIM2_CCR1 at value B201 is indicated by arrows pointing to the text 'Match detected on CCR1' and 'Interrupt generated if enabled'.

Write B201h in the CC1R register

TIM2_CNT: 0039, 003A, 003B, ..., B200, B201

TIM2_CCR1: 003A, ..., B201

oc1ref=OC1: [Signal toggling at matches]

Match detected on CCR1
Interrupt generated if enabled

Timing diagram for output compare mode, toggle on OC1. It shows three signals: TIM2_CNT, TIM2_CCR1, and oc1ref=OC1. TIM2_CNT increments from 0039 to 003A, then 003B, and eventually reaches B201. TIM2_CCR1 is initially 003A and is updated to B201 after a write operation. The oc1ref=OC1 signal toggles its state at each match between TIM2_CNT and TIM2_CCR1. A write operation to the CC1R register with value B201h is shown, which updates the TIM2_CCR1 register. The match between TIM2_CNT and TIM2_CCR1 at value B201 is indicated by arrows pointing to the text 'Match detected on CCR1' and 'Interrupt generated if enabled'.

16.3.11 PWM mode

Pulse Width Modulation mode allows you to generate a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.

The PWM mode can be selected independently on each channel (one PWM per OCx output) by writing '0110' (PWM mode 1) or '0111' (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. You must enable the corresponding preload register by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the auto-reload preload register (in upcounting or center-aligned modes) by setting the ARPE bit in the TIMx_CR1 register.

As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, you have to initialize all the registers by setting the UG bit in the TIMx_EGR register.

OCx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. OCx output is enabled by a combination of the CCxE, CCxNE, MOE, OSSI and OSSR bits (TIMx_CCER and TIMx_BDTR registers). Refer to the TIMx_CCER register description for more details.

In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CCRx ≤ TIMx_CNT or TIMx_CNT ≤ TIMx_CCRx (depending on the direction of the counter).

The timer is able to generate PWM in edge-aligned mode or center-aligned mode depending on the CMS bits in the TIMx_CR1 register.

PWM edge-aligned mode

Upcounting is active when the DIR bit in the TIMx_CR1 register is low. Refer to the Up Counter modes on page 309.

In the following example, we consider PWM mode 1. The reference PWM signal OCxREF is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the compare value in TIMx_CCRx is greater than the auto-reload value (in TIMx_ARR) then OCxREF is held at '1'. If the compare value is 0 then OCxRef is held at '0'.

Figure 58 shows some edge-aligned PWM waveforms in an example where TIMx_ARR=8.

Figure 58. Edge-aligned PWM waveforms (ARR=8)

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register counting from 0 to 8, then resetting to 0. For CCRx=4, OCXREF is low from counter 0 to 3 and high from 4 to 7, with a CCxIF flag pulse at counter 4. For CCRx=8, OCXREF is low from 0 to 7 and high from 8 to 7 (next cycle), with a CCxIF flag pulse at counter 8. For CCRx>8, OCXREF is held high at '1' and CCxIF is low. For CCRx=0, OCXREF is held low at '0' and CCxIF is low.
Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register counting from 0 to 8, then resetting to 0. For CCRx=4, OCXREF is low from counter 0 to 3 and high from 4 to 7, with a CCxIF flag pulse at counter 4. For CCRx=8, OCXREF is low from 0 to 7 and high from 8 to 7 (next cycle), with a CCxIF flag pulse at counter 8. For CCRx>8, OCXREF is held high at '1' and CCxIF is low. For CCRx=0, OCXREF is held low at '0' and CCxIF is low.

Downcounting is active when DIR bit in TIMx_CR1 register is high. Refer to the Downcounting mode on page 312

In PWM mode 1, the reference signal OCxRef is low as long as TIMx_CNT > TIMx_CCRx else it becomes high. If the compare value in TIMx_CCRx is greater than the auto-reload value in TIMx_ARR, then OCxREF is held at '1'. 0% PWM is not possible in this mode.

PWM center-aligned mode

Center-aligned mode is active when the CMS bits in TIMx_CR1 register are different from '00' (all the remaining configurations having the same effect on the OCxRef/OCx signals). The compare flag is set when the counter counts up, when it counts down or both when it counts up and down depending on the CMS bits configuration. The direction bit (DIR) in the TIMx_CR1 register is updated by hardware and must not be changed by software. Refer to the Center-aligned mode (up/down counting) on page 314.

Figure 59 shows some center-aligned PWM waveforms in an example where:

Figure 59. Center-aligned PWM waveforms (ARR=8)

Center-aligned PWM waveforms (ARR=8) timing diagram showing Counter register counting up 0 to 8 and down 8 to 0, along with OCxREF and CCxIF waveforms for CCRx=4, CCRx=7, CCRx=8, CCRx>8, and CCRx=0 under CMS=01, CMS=10, CMS=11 modes.

AI14681b

Center-aligned PWM waveforms (ARR=8) timing diagram showing Counter register counting up 0 to 8 and down 8 to 0, along with OCxREF and CCxIF waveforms for CCRx=4, CCRx=7, CCRx=8, CCRx>8, and CCRx=0 under CMS=01, CMS=10, CMS=11 modes.

Hints on using center-aligned mode

16.3.12 Asymmetric PWM mode

Asymmetric mode allows two center-aligned PWM signals to be generated with a programmable phase shift. While the frequency is determined by the value of the TIMx_ARR register, the duty cycle and the phase-shift are determined by a pair of TIMx_CCRx register. One register controls the PWM during up-counting, the second during down counting, so that PWM is adjusted every half PWM cycle:

Asymmetric PWM mode can be selected independently on two channel (one OCx output per pair of CCR registers) by writing '1110' (Asymmetric PWM mode 1) or '1111' (Asymmetric PWM mode 2) in the OCxM bits in the TIMx_CCMRx register.

Note: The OCxM[3:0] bit field is split into two parts for compatibility reasons, the most significant bit is not contiguous with the 3 least significant ones.

When a given channel is used as asymmetric PWM channel, its complementary channel can also be used. For instance, if an OC1REFC signal is generated on channel 1 (Asymmetric PWM mode 1), it is possible to output either the OC2REF signal on channel 2, or an OC2REFC signal resulting from asymmetric PWM mode 1.

Figure 60 represents an example of signals that can be generated using Asymmetric PWM mode (channels 1 to 4 are configured in Asymmetric PWM mode 1). Together with the deadtime generator, this allows a full-bridge phase-shifted DC to DC converter to be controlled.

Figure 60. Generation of 2 phase-shifted PWM signals with 50% duty cycle

Timing diagram showing the generation of two phase-shifted PWM signals (OC1REFC and OC3REFC) with 50% duty cycle. The Counter register counts from 0 to 7 and then back down to 0. OC1REFC is high from counter value 0 to 7. OC3REFC is high from counter value 3 to 5. The diagram includes labels for CCR1=0, CCR2=8, CCR3=3, and CCR4=5.

The diagram illustrates the generation of two phase-shifted PWM signals, OC1REFC and OC3REFC, using Asymmetric PWM mode. The Counter register counts up from 0 to 7 and then counts down from 7 to 0. The OC1REFC signal is high from counter value 0 to 7. The OC3REFC signal is high from counter value 3 to 5. The diagram includes labels for CCR1=0, CCR2=8, CCR3=3, and CCR4=5.

Timing diagram showing the generation of two phase-shifted PWM signals (OC1REFC and OC3REFC) with 50% duty cycle. The Counter register counts from 0 to 7 and then back down to 0. OC1REFC is high from counter value 0 to 7. OC3REFC is high from counter value 3 to 5. The diagram includes labels for CCR1=0, CCR2=8, CCR3=3, and CCR4=5.

16.3.13 Combined PWM mode

Combined PWM mode allows two edge or center-aligned PWM signals to be generated with programmable delay and phase shift between respective pulses. While the frequency is determined by the value of the TIMx_ARR register, the duty cycle and delay are determined by the two TIMx_CCRx registers. The resulting signals, OCxREFC, are made of an OR or AND logical combination of two reference PWMs:

Combined PWM mode can be selected independently on two channels (one OCx output per pair of CCR registers) by writing '1100' (Combined PWM mode 1) or '1101' (Combined PWM mode 2) in the OCxM bits in the TIMx_CCMRx register.

When a given channel is used as combined PWM channel, its complementary channel must be configured in the opposite PWM mode (for instance, one in Combined PWM mode 1 and the other in Combined PWM mode 2).

Note: The OCxM[3:0] bit field is split into two parts for compatibility reasons, the most significant bit is not contiguous with the 3 least significant ones.

Figure 61 represents an example of signals that can be generated using Asymmetric PWM mode, obtained with the following configuration:

Figure 61. Combined PWM mode on channel 1 and 3

Timing diagram for Combined PWM mode on channel 1 and 3. The diagram shows the following signals over time: OC4 (sawtooth), OC3 (sawtooth), OC2 (sawtooth), OC1 (sawtooth), OC1REF (square wave), OC2REF (square wave), OC3REF (square wave), OC4REF (square wave), OC1REFC (square wave), and OC3REFC (square wave). The diagram illustrates the relationship between the output signals and their corresponding reference signals. The equations for the reference signals are: OC1REFC = OC1REF AND OC2REF and OC3REFC = OC3REF OR OC4REF.

OC1REFC = OC1REF AND OC2REF
OC3REFC = OC3REF OR OC4REF

Timing diagram for Combined PWM mode on channel 1 and 3. The diagram shows the following signals over time: OC4 (sawtooth), OC3 (sawtooth), OC2 (sawtooth), OC1 (sawtooth), OC1REF (square wave), OC2REF (square wave), OC3REF (square wave), OC4REF (square wave), OC1REFC (square wave), and OC3REFC (square wave). The diagram illustrates the relationship between the output signals and their corresponding reference signals. The equations for the reference signals are: OC1REFC = OC1REF AND OC2REF and OC3REFC = OC3REF OR OC4REF.

16.3.14 Clearing the OCxREF signal on an external event

The OCxREF signal of a given channel can be cleared when a high level is applied on the ETRF input (OCxCE enable bit in the corresponding TIMx_CCMRx register set to 1) if TIMx_SMCR.OCCS bit is set to 1. The OCxREF signal remains low until the next update event (UEV) occurs.

This function can only be used in Output compare and PWM modes. It does not work in Forced mode.

  1. 1. The External Trigger Prescaler should be kept off: bits ETPS[1:0] of the TIMx_SMCR register set to '00'.
  2. 2. The external clock mode 2 must be disabled: bit ECE of the TIMx_SMCR register set to '0'.
  3. 3. The External Trigger Polarity (ETP) and the External Trigger Filter (ETF) can be configured according to the user needs.

Figure 62 shows the behavior of the OCxREF signal when the ETRF Input becomes High, for both values of the enable bit OCxCE. In this example, the timer TIMx is programmed in PWM mode.

Figure 62. Clearing TIMx OCxREF

Timing diagram showing the clearing of TIMx OCxREF. It includes four signals: Counter (CNT), ETRF, OCxREF (OCxCE='0'), and OCxREF (OCxCE='1'). The Counter (CNT) is a sawtooth wave with a threshold (CCRx) indicated. The ETRF signal is a square wave. The OCxREF (OCxCE='0') signal is a square wave that is low when ETRF is high and high when ETRF is low. The OCxREF (OCxCE='1') signal is a square wave that is high when ETRF is high and low when ETRF is low. Two arrows point to the ETRF signal: one labeled 'ETRF becomes high' and another labeled 'ETRF still high'.

The diagram illustrates the timing relationship between the Counter (CNT), ETRF, and OCxREF signals. The Counter (CNT) is a sawtooth wave that resets to zero when it reaches the CCRx threshold. The ETRF signal is a square wave that controls the OCxREF signal. The OCxREF (OCxCE='0') signal is a square wave that is low when ETRF is high and high when ETRF is low. The OCxREF (OCxCE='1') signal is a square wave that is high when ETRF is high and low when ETRF is low. Two arrows point to the ETRF signal: one labeled 'ETRF becomes high' and another labeled 'ETRF still high'.

Timing diagram showing the clearing of TIMx OCxREF. It includes four signals: Counter (CNT), ETRF, OCxREF (OCxCE='0'), and OCxREF (OCxCE='1'). The Counter (CNT) is a sawtooth wave with a threshold (CCRx) indicated. The ETRF signal is a square wave. The OCxREF (OCxCE='0') signal is a square wave that is low when ETRF is high and high when ETRF is low. The OCxREF (OCxCE='1') signal is a square wave that is high when ETRF is high and low when ETRF is low. Two arrows point to the ETRF signal: one labeled 'ETRF becomes high' and another labeled 'ETRF still high'.

Note: In case of a PWM with a 100% duty cycle (if CCRx>ARR), then OCxREF is enabled again at the next counter overflow.

16.3.15 One-pulse mode

One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.

Starting the counter can be controlled through the slave mode controller. Generating the waveform can be done in output compare mode or PWM mode. You select One-pulse mode by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.

A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting (when the timer is waiting for the trigger), the configuration must be:

Figure 63. Example of one pulse mode.

Timing diagram for One-pulse mode showing TI2 trigger, OC1REF, OC1 output, and Counter value over time.

The diagram illustrates the operation of One-pulse mode. It shows four signals over time (t):

Key time intervals are marked:

Timing diagram for One-pulse mode showing TI2 trigger, OC1REF, OC1 output, and Counter value over time.

For example you may want to generate a positive pulse on OC1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\) as soon as a positive edge is detected on the TI2 input pin.

Let's use TI2FP2 as trigger 1:

The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).

In our example, the DIR and CMS bits in the TIMx_CR1 register should be low.

You only want 1 pulse (Single mode), so you write '1' in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over from the auto-reload value back to 0). When OPM bit in the TIMx_CR1 register is set to '0', so the Repetitive Mode is selected.

Particular case: OCx fast enable:

In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{\text{DELAY}}\) min we can get.

If you want to output a waveform with the minimum delay, you can set the OCxFE bit in the TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.

16.3.16 Retriggerable one pulse mode (OPM)

This mode allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length, but with the following differences with Non-retriggerable one pulse mode described in Section 16.3.15:

The timer must be in Slave mode, with the bits SMS[3:0] = '1000' (Combined Reset + trigger mode) in the TIMx_SMCR register, and the OCxM[3:0] bits set to '1000' or '1001' for Retriggerable OPM mode 1 or 2.

If the timer is configured in Up-counting mode, the corresponding CCRx must be set to 0 (the ARR register sets the pulse length). If the timer is configured in Down-counting mode, the ARR must be set to 0 (the CCRx register sets the pulse length).

Note: The OCxM[3:0] and SMS[3:0] bit fields are split into two parts for compatibility reasons, the most significant bit are not contiguous with the 3 least significant ones.
In Retriggerable one pulse mode, the CCxIF flags are not significant.

Figure 64. Retriggerable one pulse mode

Timing diagram for Retriggerable one pulse mode showing TRGI, Counter, and Output signals.

The diagram illustrates the behavior of the timer in Retriggerable one pulse mode. It consists of three horizontal signal lines: TRGI, Counter, and Output. Vertical dashed lines indicate the timing of events across the signals.

Timing diagram for Retriggerable one pulse mode showing TRGI, Counter, and Output signals.

16.3.17 Encoder interface mode

To select Encoder Interface mode write SMS='001' in the TIMx_SMCR register if the counter is counting on TI2 edges only, SMS='010' if it is counting on TI1 edges only and SMS='011' if it is counting on both TI1 and TI2 edges.

Select the TI1 and TI2 polarity by programming the CC1P and CC2P bits in the TIMx_CCER register. When needed, you can program the input filter as well. CC1NP and CC2NP must be kept low.

The two inputs TI1 and TI2 are used to interface to a quadrature encoder. Refer to Table 79. The counter is clocked by each valid transition on TI1FP1 or TI2FP2 (TI1 and TI2 after input filter and polarity selection, TI1FP1=TI1 if not filtered and not inverted, TI2FP2=TI2 if not filtered and not inverted) assuming that it is enabled (CEN bit in TIMx_CR1 register written to '1'). The sequence of transitions of the two inputs is evaluated and generates count pulses as well as the direction signal. Depending on the sequence the counter counts up or down, the DIR bit in the TIMx_CR1 register is modified by hardware accordingly. The DIR bit is calculated at each transition on any input (TI1 or TI2), whatever the counter is counting on TI1 only, TI2 only or both TI1 and TI2.

Encoder interface mode acts simply as an external clock with direction selection. This means that the counter just counts continuously between 0 and the auto-reload value in the TIMx_ARR register (0 to ARR or ARR down to 0 depending on the direction). So you must configure TIMx_ARR before starting. In the same way, the capture, compare, prescaler, repetition counter, trigger output features continue to work as normal. Encoder mode and External clock mode 2 are not compatible and must not be selected together.

Note: The prescaler must be set to zero when encoder mode is enabled.

In this mode, the counter is modified automatically following the speed and the direction of the quadrature encoder and its content, therefore, always represents the encoder's position. The count direction corresponds to the rotation direction of the connected sensor. The table summarizes the possible combinations, assuming TI1 and TI2 don't switch at the same time.

Table 79. Counting direction versus encoder signals

Active edgeLevel on opposite signal (TI1FP1 for TI2, TI2FP2 for TI1)TI1FP1 signalTI2FP2 signal
RisingFallingRisingFalling
Counting on TI1 onlyHighDownUpNo CountNo Count
LowUpDownNo CountNo Count
Counting on TI2 onlyHighNo CountNo CountUpDown
LowNo CountNo CountDownUp
Counting on TI1 and TI2HighDownUpUpDown
LowUpDownDownUp

A quadrature encoder can be connected directly to the MCU without external interface logic. However, comparators are normally be used to convert the encoder's differential outputs to digital signals. This greatly increases noise immunity. The third encoder output which indicate the mechanical zero position, may be connected to an external interrupt input and trigger a counter reset.

The Figure 65 gives an example of counter operation, showing count signal generation and direction control. It also shows how input jitter is compensated where both edges are selected. This might occur if the sensor is positioned near to one of the switching points. For this example we assume that the configuration is the following:

Figure 65. Example of counter operation in encoder interface mode.

Timing diagram showing TI1, TI2, and Counter signals over time. The diagram is divided into five phases: forward, jitter, backward, jitter, and forward. TI1 and TI2 are square wave signals that are 90 degrees out of phase. The Counter signal is a staircase waveform that increments during the first 'forward' phase, remains constant during the 'jitter' phases, decrements during the 'backward' phase, and increments again during the final 'forward' phase. Labels 'up' and 'down' are placed under the counter waveform to indicate its direction of change.
Timing diagram showing TI1, TI2, and Counter signals over time. The diagram is divided into five phases: forward, jitter, backward, jitter, and forward. TI1 and TI2 are square wave signals that are 90 degrees out of phase. The Counter signal is a staircase waveform that increments during the first 'forward' phase, remains constant during the 'jitter' phases, decrements during the 'backward' phase, and increments again during the final 'forward' phase. Labels 'up' and 'down' are placed under the counter waveform to indicate its direction of change.

Figure 66 gives an example of counter behavior when TI1FP1 polarity is inverted (same configuration as above except CC1P='1').

Figure 66. Example of encoder interface mode with TI1FP1 polarity inverted.

Timing diagram showing TI1, TI2, and Counter signals. TI1 and TI2 are square waves. The Counter signal is a staircase waveform that counts down during 'forward' and 'backward' phases and counts up during 'jitter' phases. The Counter signal is labeled 'down' during the first and third phases, and 'up' during the second phase.

The diagram illustrates the behavior of an encoder interface mode with TI1FP1 polarity inverted. It shows three signals over time: TI1, TI2, and the Counter. TI1 and TI2 are square waves representing the encoder's output. The Counter signal is a staircase waveform that counts down during 'forward' and 'backward' phases and counts up during 'jitter' phases. The Counter signal is labeled 'down' during the first and third phases, and 'up' during the second phase.

Timing diagram showing TI1, TI2, and Counter signals. TI1 and TI2 are square waves. The Counter signal is a staircase waveform that counts down during 'forward' and 'backward' phases and counts up during 'jitter' phases. The Counter signal is labeled 'down' during the first and third phases, and 'up' during the second phase.

The timer, when configured in Encoder Interface mode provides information on the sensor's current position. You can obtain dynamic information (speed, acceleration, deceleration) by measuring the period between two encoder events using a second timer configured in capture mode (not available in the STM32WB09xE device). The output of the encoder which indicates the mechanical zero can be used for this purpose. Depending on the time between two events, the counter can also be read at regular times. You can do this by latching the counter value into a third input capture register if available (then the capture signal must be periodic and can be generated by another timer), when available it's also possible to read its value through a DMA request generated by a Real -Time clock.

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag (UIF) into the timer counter register's bit 31 (TIMxCNT[31]). This allows both the counter value and a potential roll-over condition signaled by the UIFCPY flag to be read in an atomic way. It eases the calculation of angular speed by avoiding race conditions caused, for instance, by a processing shared between a background task (counter reading) and an interrupt (update interrupt).

There is no latency between the UIF and UIFCPY flag assertions.

In 32-bit timer implementations, when the IUFREMAP bit is set, bit 31 of the counter is overwritten by the UIFCPY flag upon read access (the counter's most significant bit is only accessible in write mode).

16.3.18 UIF bit remapping

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the Update Interrupt Flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This allows both the counter value and a potential roll-over condition signaled by the UIFCPY flag to be read in an atomic way. In particular cases, it can ease the calculations by avoiding race conditions, caused for instance by a processing shared between a background task (counter reading) and an interrupt (Update Interrupt).

There is no latency between the UIF and UIFCPY flags assertion.

16.3.19 Timer input XOR function

The TI1S bit in the TIMx_CR2 register, allows the input filter of channel 1 to be connected to the output of an XOR gate, combining the two input pins TIMx_CH1 and TIMx_CH2.

The XOR output can be used with all the timer input functions such as trigger or input capture. It is convenient to measure the interval between edges on two input signals, as per Figure 67 below.

Figure 67. Measuring time interval between edges on 3 signals

Timing diagram showing three input signals (TI1, TI2, TI3), their XOR combination, and the resulting TIMx Counter increments.

The diagram illustrates the operation of the Timer input XOR function. It shows five vertically aligned waveforms over time:

Vertical dashed lines align the edges of the input signals with the corresponding counter increments, demonstrating how the XOR function effectively combines the edges of TI1 and TI2 into a single stream for timing measurement.

Timing diagram showing three input signals (TI1, TI2, TI3), their XOR combination, and the resulting TIMx Counter increments.

16.3.20 DMA burst mode

The TIMx timers have the capability to generate multiple DMA requests on a single event. The main purpose is to be able to re-program several timer registers multiple times without software overhead, but it can also be used to read several registers in a row, at regular intervals.

The DMA controller destination is unique and must point to the virtual register TIMx_DMAR. On a given timer event, the timer launches a sequence of DMA requests (burst). Each write into the TIMx_DMAR register is actually redirected to one of the timer registers.

The DBL[4:0] bits in the TIMx_DCR register set the DMA burst length. The timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address, i.e. the number of transfers (either in half-words or in bytes).

The DBA[4:0] bits in the TIMx_DCR registers define the DMA base address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.

Example:

00000: TIMx_CR1,

00001: TIMx_CR2,

For example, the timer DMA burst feature could be used to update the contents of the CCRx registers (x = 2,3,4) on an update event, with the DMA transferring half words into the CCRx registers.

This is done in the following steps:

  1. 1. Configure the corresponding DMA channel as follows:
    • – DMA channel peripheral address is the DMAR register address
    • – DMA channel memory address is the address of the buffer in the RAM containing the data to be transferred by DMA into the CCRx registers.
    • – Number of data to transfer = 3 (See note below).
    • – Circular mode disabled.
  2. 2. Configure the DCR register by configuring the DBA and DBL bit fields as follows:
    DBL = 3 transfers, DBA = 0xE.
  3. 3. Enable the TIMx update DMA request (set the UDE bit in the DIER register).
  4. 4. Enable TIMx
  5. 5. Enable the DMA channel

This example is for the case where every CCRx register is to be updated once. If every CCRx register is to be updated twice for example, the number of data to transfer should be 6. Let's take the example of a buffer in the RAM containing data1, data2, data3, data4, data5 and data6. The data is transferred to the CCRx registers as follows: on the first update DMA request, data1 is transferred to CCR2, data2 is transferred to CCR3, data3 is transferred to CCR4 and on the second update DMA request, data4 is transferred to CCR2, data5 is transferred to CCR3 and data6 is transferred to CCR4.

16.4 TIM2 registers

Refer to Section 1.2: List of abbreviations for registers for a list of abbreviations used in register descriptions.

16.4.1 TIM2 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.UIFRE
MAP
Res.CKD[1:0]ARPECMS[1:0]DIROPMURSUDISCEN
rwrwrwrwrwrwrwrwrwrwrw

Bits 31:12 Reserved, always read as 0

Bit 11 UIFREMAP: UIF status bit remapping

0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.

1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.

Bits 10 Reserved, always read as 0

Bits 9:8 CKD[1:0]: Clock division

This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (\(t_{DTS}\)) used by the dead-time generators and the digital filters (ETR, TIx),

00: \(t_{DTS}=t_{CK\_INT}\)

01: \(t_{DTS}=2*t_{CK\_INT}\)

10: \(t_{DTS}=4*t_{CK\_INT}\)

11: Reserved, do not program this value

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered

1: TIMx_ARR register is buffered

Bits 6:5 CMS[1:0]: Center-aligned mode selection

00: Edge-aligned mode. The counter counts up or down depending on the direction bit (DIR).

01: Center-aligned mode 1. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set only when the counter is counting down.

10: Center-aligned mode 2. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set only when the counter is counting up.

11: Center-aligned mode 3. The counter counts up and down alternatively. Output compare interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set both when the counter is counting up or down.

Note: It is not allowed to switch from edge-aligned mode to center-aligned mode as long as the counter is enabled (CEN=1)

Bit 4 DIR: Direction

Note: This bit is read only when the timer is configured in Center-aligned mode or Encoder mode.

Bit 3 OPM: One pulse mode

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

Buffered registers are then loaded with their preload values.

Bit 0 CEN: Counter enable

Note: External clock, gated mode and encoder mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

16.4.2 TIM2 control register 2 (TIMx_CR2)

Address offset: 0x04

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.TI1SMMS[2:0]CCDSRes.Res.Res.Res.
rwrwrwrwrw

Bits 31:8 Reserved, always read as 0

Bit 7 TI1S: TI1 selection

0: The TIMx_CH1 pin is connected to TI1 input

1: The TIMx_CH1, CH2 and CH3 pins are connected to the TI1 input (XOR combination)

Bits 6:4 MMS[1:0]: Master mode selection

These bits allow to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:

000: Reset - the UG bit from the TIMx_EGR register is used as trigger output (TRGO). If the reset is generated by the trigger input (slave mode controller configured in reset mode) then the signal on TRGO is delayed compared to the actual reset.

001: Enable - the Counter Enable signal CNT_EN is used as trigger output (TRGO). It is useful to start several timers at the same time or to control a window in which a slave timer is enable. The Counter Enable signal is generated by a logic OR between CEN control bit and the trigger input when configured in gated mode. When the Counter Enable signal is controlled by the trigger input, there is a delay on TRGO, except if the master/slave mode is selected (see the MSM bit description in TIMx_SMCR register).

010: Update - The update event is selected as trigger output (TRGO). For instance a master timer can then be used as a prescaler for a slave timer.

011: Compare Pulse - The trigger output send a positive pulse when the CC1IF flag is to be set (even if it was already high), as soon as a capture or a compare match occurred. (TRGO).

100: Compare - OC1REF signal is used as trigger output (TRGO)

101: Compare - OC2REF signal is used as trigger output (TRGO)

110: Compare - OC3REF signal is used as trigger output (TRGO)

Bit 3 CCDS: Capture/compare DMA selection

0: CCx DMA request sent when CCx event occurs

1: CCx DMA requests sent when update event occurs

Bit 2:0 Reserved, always read as 0

16.4.3 TIM2 slave mode control register (TIMx_SMCR)

Address offset: 0x08

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TS[4:3]Res.Res.Res.SMS[3]
rwrwrw
1514131211109876543210
ETPECEETPS[1:0]ETF[3:0]MSMTS[2:0]OCCSSMS[2:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:22 Reserved, always read as 0

Bits 21:20 TS[4:3]: Trigger selection.

Bits 19:17 Reserved, always read as 0

Bit 16 SMS[3]: Slave mode selection - bit 3
Refer to SMS description - bits2:0

Bit 15 ETP: External trigger polarity
This bit selects whether ETR or \(\overline{ETR}\) is used for trigger operations
0: ETR is non-inverted, active at high level or rising edge.
1: ETR is inverted, active at low level or falling edge.

Bit 14 ECE: External clock enable
This bit enables External clock mode 2.
0: External clock mode 2 disabled
1: External clock mode 2 enabled. The counter is clocked by any active edge on the ETRF signal.

Note: 1: Setting the ECE bit has the same effect as selecting external clock mode 1 with TRGI connected to ETRF (SMS=111 and TS=111).
2: It is possible to simultaneously use external clock mode 2 with the following slave modes: reset mode, gated mode and trigger mode. Nevertheless, TRGI must not be connected to ETRF in this case (TS bits must not be 111).
3: If external clock mode 1 and external clock mode 2 are enabled at the same time, the external clock input is ETRF.

Bits 13:12 ETPS[1:0]: External trigger prescaler
External trigger signal ETRP frequency must be at most 1/4 of TIMxCLK frequency. A prescaler can be enabled to reduce ETRP frequency. It is useful when inputting fast external clocks.
00: Prescaler OFF
01: ETRP frequency divided by 2
10: ETRP frequency divided by 4
11: ETRP frequency divided by 8

Bits 11:8 ETF[3:0]: External trigger filter

This bit-field then defines the frequency used to sample ETRP signal and the length of the digital filter applied to ETRP. The digital filter is made of an event counter in which N events are needed to validate a transition on the output:

0000: No filter, sampling is done at fDTS

0001: fSAMPLING=fCK_INT, N=2

0010: fSAMPLING=fCK_INT, N=4

0011: fSAMPLING=fCK_INT, N=8

0100: fSAMPLING=fDTS/2, N=6

0101: fSAMPLING=fDTS/2, N=8

0110: fSAMPLING=fDTS/4, N=6

0111: fSAMPLING=fDTS/4, N=8

1000: fSAMPLING=fDTS/8, N=6

1001: fSAMPLING=fDTS/8, N=8

1010: fSAMPLING=fDTS/16, N=5

1011: fSAMPLING=fDTS/16, N=6

1100: fSAMPLING=fDTS/16, N=8

1101: fSAMPLING=fDTS/32, N=5

1110: fSAMPLING=fDTS/32, N=6

1111: fSAMPLING=fDTS/32, N=8

Bit 7 MSM: Master/Slave mode.

0: No action

1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect synchronization between the current timer and its slaves (through TRGO). It is useful if we want to synchronize several timers on a single external event.

Bits 6:4 TS[2:0]: Trigger selection

This bit-field selects the trigger input to be used to synchronize the counter.

Others: Reserved

Note: These bits must be changed only when they are not used (e.g. when SMS=000) to avoid wrong edge detections at the transition.

Bit 3 OCCS: OCREF clear selection

This bit is used to select the OCREF clear source.

Bits 2:0 SMS: Slave mode selection

When external signals are selected the active edge of the trigger signal (TRGI) is linked to the polarity selected on the external input (see Input Control register and Control Register description).

Note: The gated mode must not be used if TI1F_ED is selected as the trigger input (TS='100'). Indeed, TI1F_ED outputs 1 pulse for each transition on TI1F, whereas the gated mode checks the level of the trigger signal.

Table 80. TIMx Internal trigger connection

Slave TIMITR0ITR1ITR2 - ITR8
TIM2TIM16--

16.4.4 TIM2 DMA/interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.CC4DECC3DECC2DECC1DEUDERes.TIERes.CC4IECC3IECC2IECC1IEUIE
rwrwrwrwrwrwrwrwrwrwrw

Bits 31:13 Reserved, always read as 0.

Bit 12 CC4DE: Capture/Compare 4 DMA request enable
0: CC4 DMA request disabled
1: CC4 DMA request enabled

Bit 11 CC3DE: Capture/Compare 3 DMA request enable
0: CC3 DMA request disabled
1: CC3 DMA request enabled

Bit 10 CC2DE: Capture/Compare 2 DMA request enable
0: CC2 DMA request disabled
1: CC2 DMA request enabled

Bit 9 CC1DE: Capture/Compare 1 DMA request enable
0: CC1 DMA request disabled
1: CC1 DMA request enabled

Bit 8 UDE: Update DMA request enable
0: Update DMA request disabled
1: Update DMA request enabled

Bit 7 Reserved, always read as 0.

Bit 6 TIE: Trigger interrupt enable
0: Trigger interrupt disabled
1: Trigger interrupt enabled

Bit 5 Reserved, always read as 0.

Bit 4 CC4IE: Capture/Compare 4 interrupt enable
0: CC4 interrupt disabled
1: CC4 interrupt enabled

Bit 3 CC3IE: Capture/Compare 3 interrupt enable
0: CC3 interrupt disabled
1: CC3 interrupt enabled

Bit 2 CC2IE: Capture/Compare 2 interrupt enable

0: CC2 interrupt disabled

1: CC2 interrupt enabled

Bit 1 CC1IE: Capture/Compare 1 interrupt enable

0: CC1 interrupt disabled

1: CC1 interrupt enabled

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled

1: Update interrupt enabled

16.4.5 TIM2 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.CC4OFCC3OFCC2OFCC1OFRes.Res.TIFRes.CC4IFCC3IFCC2IFCC1IFUIF
rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0

Bits 31:13 Reserved, always read as 0.

Bit 12 CC4OF: Capture/Compare 4 overcapture flag
refer to CC1OF description

Bit 11 CC3OF: Capture/Compare 3 overcapture flag
refer to CC1OF description

Bit 10 CC2OF: Capture/Compare 2 overcapture flag
refer to CC1OF description

Bit 9 CC1OF: Capture/Compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.

0: No overcapture has been detected.

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bit 8:7 Reserved, always read as 0.

Bit 6 TIF: Trigger interrupt flag

This flag is set by hardware on trigger event (active edge detected on TRGI input when the slave mode controller is enabled in all modes but gated mode. It is set when the counter starts or stops when gated mode is selected. It is cleared by software.

0: No trigger event occurred.

1: Trigger interrupt pending.

Bit 5 Reserved, always read as 0.

Bit 4 CC4IF: Capture/Compare 4 interrupt flag
refer to CC1IF description

16.4.6 TIM2 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.TGRes.CC4GCC3GCC2GCC1GUG
wwwwww

Bits 31:7 Reserved, always read as 0.

Bit 6 TG: Trigger generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: The TIF flag is set in TIMx_SR register. Related interrupt can occur if enabled.

Bits 5 Reserved, always read as 0.

Bit 4 CC4G: Capture/Compare 4 generation

refer to CC1G description

Bit 3 CC3G: Capture/Compare 3 generation

refer to CC1G description

Bit 2 CC2G: Capture/Compare 2 generation

refer to CC1G description

Bit 1 CC1G: Capture/Compare 1 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled.

If channel CC1 is configured as input:

The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected). The counter is cleared if the center-aligned mode is selected or if DIR=0 (upcounting), else it takes the auto-reload value (TIMx_ARR) if DIR=1 (downcounting).

16.4.7 TIM2 capture/compare mode register 1 (TIMx_CCMR1)

Address offset: 0x18

Reset value: 0x0000 0000

The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function in input and in output mode. For a given bit, OCxx describes its function when the channel is configured in output, ICxx describes its function when the channel is configured in input. So you must take care that the same bit can have a different meaning for the input stage and for the output stage.

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.OC2M[3]Res.Res.Res.Res.Res.Res.Res.OC1M[3]
Res.Res.
1514131211109876543210
OC2
CE
OC2M[2:0]OC2
PE
OC2
FE
CC2S[1:0]OC1
CE
OC1M[2:0]OC1
PE
OC1
FE
CC1S[1:0]
IC2F[3:0]IC2PSC[1:0]IC1F[3:0]IC1PSC[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode:

Bits 31:25 Reserved, always read as 0.

Bit 24 OC2M[3]: Output Compare 2 mode - bit 3

Bits 23:17 Reserved, always read as 0.

Bits 16:14 OC1M[3]: Output Compare 1 mode - bit 3

Refer to OC1M description on bits 6:4

Bit 15 OC2CE: Output Compare 2 clear enable

Bits 14:12 OC2M[2:0]: Output Compare 2 mode

Bit 11 OC2PE: Output Compare 2 preload enable

Bit 10 OC2FE: Output Compare 2 fast enable

Bits 9:8 CC2S[1:0]: Capture/Compare 2 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode is working only if an internal trigger input is selected through the TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = '0' in TIMx_CCER).

Bit 7 OC1CE: Output Compare 1 clear enable

OC1CE: Output Compare 1 Clear Enable

0: OC1Ref is not affected by the ETRF Input

1: OC1Ref is cleared as soon as a High level is detected on ETRF input

Bits 6:4 OC1M: Output Compare 1 mode

These bits define the behavior of the output reference signal OC1REF from which OC1 and OC1N are derived. OC1REF is active high whereas OC1 and OC1N active level depends on CC1P and CC1NP bits.

0000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.(this mode is used to generate a timing base).

0001: Set channel 1 to active level on match. OC1REF signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

0010: Set channel 1 to inactive level on match. OC1REF signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

0011: Toggle - OC1REF toggles when TIMx_CNT=TIMx_CCR1.

0100: Force inactive level - OC1REF is forced low.

0101: Force active level - OC1REF is forced high.

0110: PWM mode 1 - In upcounting, channel 1 is active as long as TIMx_CNT<TIMx_CCR1 else inactive. In downcounting, channel 1 is inactive (OC1REF='0') as long as TIMx_CNT>TIMx_CCR1 else active (OC1REF='1').

0111: PWM mode 2 - In upcounting, channel 1 is inactive as long as TIMx_CNT<TIMx_CCR1 else active. In downcounting, channel 1 is active as long as TIMx_CNT>TIMx_CCR1 else inactive.

1000: Retriggerable OPM mode 1 - In up-counting mode, the channel is active until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update. In down-counting mode, the channel is inactive until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes inactive again at the next update.

1001: Retriggerable OPM mode 2 - In up-counting mode, the channel is inactive until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 2 and the channels becomes inactive again at the next update. In down-counting mode, the channel is active until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update.

1010: Reserved,

1011: Reserved,

1100: Combined PWM mode 1 - OC1REF has the same behavior as in PWM mode 1. OC1REFC is the logical OR between OC1REF and OC2REF.

1101: Combined PWM mode 2 - OC1REF has the same behavior as in PWM mode 2. OC1REFC is the logical AND between OC1REF and OC2REF.

1110: Asymmetric PWM mode 1 - OC1REF has the same behavior as in PWM mode 1. OC1REFC outputs OC1REF when the counter is counting up, OC2REF when it is counting down.

1111: Asymmetric PWM mode 2 - OC1REF has the same behavior as in PWM mode 2. OC1REFC outputs OC1REF when the counter is counting up, OC2REF when it is counting down.

Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

2: In PWM mode, the OCREf level changes only when the result of the comparison changes or when the output compare mode switches from "frozen" mode to "PWM" mode.

Bit 3 OC1PE: Output Compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.

Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

2: The PWM mode can be used without validating the preload register only in one pulse mode (OPM bit set in TIMx_CR1 register). Else the behavior is not guaranteed.

Bit 2 OC1FE: Output Compare 1 fast enable

This bit is used to accelerate the effect of an event on the trigger in input on the CC output.

0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.

1: An active edge on the trigger input acts like a compare match on CC1 output. Then, OC is set to the compare level independently from the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OCFE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S: Capture/Compare 1 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: CC1 channel is configured as input, IC1 is mapped on TI2

11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC1S bits are writable only when the channel is OFF (CC1E = '0' in TIMx_CCER).

Input capture mode

Bits 31:16 Reserved, always read as 0.

Bits 15:12 IC2F: Input capture 2 filter

Bits 11:10 IC2PSC[1:0]: Input capture 2 prescaler

Bits 9:8 CC2S: Capture/Compare 2 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC2 channel is configured as output

01: CC2 channel is configured as input, IC2 is mapped on TI2

10: CC2 channel is configured as input, IC2 is mapped on TI1

11: CC2 channel is configured as input, IC2 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC2S bits are writable only when the channel is OFF (CC2E = '0' in TIMx_CCER).

Bits 7:4 IC1F[3:0]: Input capture 1 filter

This bit-field defines the frequency used to sample TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N events are needed to validate a transition on the output:

0000: No filter, sampling is done at fDTS

0001: fSAMPLING=fCK_INT, N=2

0010: fSAMPLING=fCK_INT, N=4

0011: fSAMPLING=fCK_INT, N=8

0100: fSAMPLING=fDTS/2, N=6

0101: fSAMPLING=fDTS/2, N=8

0110: fSAMPLING=fDTS/4, N=6

0111: fSAMPLING=fDTS/4, N=8

1000: fSAMPLING=fDTS/8, N=6

1001: fSAMPLING=fDTS/8, N=8

1010: fSAMPLING=fDTS/16, N=5

1011: fSAMPLING=fDTS/16, N=6

1100: fSAMPLING=fDTS/16, N=8

1101: fSAMPLING=fDTS/32, N=5

1110: fSAMPLING=fDTS/32, N=6

1111: fSAMPLING=fDTS/32, N=8

Bits 3:2 IC1PSC: Input capture 1 prescaler

This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).

The prescaler is reset as soon as CC1E=’0’ (TIMx_CCER register).

00: no prescaler, capture is done each time an edge is detected on the capture input

01: capture is done once every 2 events

10: capture is done once every 4 events

11: capture is done once every 8 events

Bits 1:0 CC1S: Capture/Compare 1 Selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

10: CC1 channel is configured as input, IC1 is mapped on TI2

11: CC1 channel is configured as input, IC1 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC1S bits are writable only when the channel is OFF (CC1E = ‘0’ in TIMx_CCER).

16.4.8 TIM2 capture/compare mode register 2 (TIMx_CCMR2)

Address offset: 0x1C

Reset value: 0x0000 0000

Refer to the above CCMR1 register description.

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.OC4M[3]Res.Res.Res.Res.Res.Res.Res.OC3M[3]
rwrw
1514131211109876543210
OC4C
E
OC4M[2:0]OC4PEOC4FECC4S[1:0]OC3CEOC3M[2:0]OC3PEOC3FECC3S[1:0]
IC4F[3:0]IC4PSC[1:0]IC3F[3:0]IC3PSC[1:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Output compare mode

Bits 31:25 Reserved, always read as 0.

Bit 24 OC4M[3]: Output Compare 4 mode - bit 3

Bits 23:17 Reserved, always read as 0.

Bit 16 OC3M[3]: Output Compare 3 mode - bit 3

Bit 15 OC4CE: Output compare 4 clear enable

Bits 14:12 OC4M: Output compare 4 mode

Bit 11 OC4PE: Output compare 4 preload enable

Bit 10 OC4FE: Output compare 4 fast enable

Bits 9:8 CC4S: Capture/Compare 4 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC4 channel is configured as output

01: CC4 channel is configured as input, IC4 is mapped on TI4

10: CC4 channel is configured as input, IC4 is mapped on TI3

11: CC4 channel is configured as input, IC4 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC4S bits are writable only when the channel is OFF (CC4E = '0' in TIMx_CCER).

Bit 7 OC3CE: Output compare 3 clear enable

Bits 6:4 OC3M: Output compare 3 mode

Bit 3 OC3PE: Output compare 3 preload enable

Bit 2 OC3FE: Output compare 3 fast enable

Bits 1:0 CC3S: Capture/Compare 3 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC3 channel is configured as output

01: CC3 channel is configured as input, IC3 is mapped on TI3

10: CC3 channel is configured as input, IC3 is mapped on TI4

11: CC3 channel is configured as input, IC3 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC3S bits are writable only when the channel is OFF (CC3E = '0' in TIMx_CCER).

Input capture mode

Bits 31:16 Reserved, always read as 0.

Bits 15:12 IC4F: Input capture 4 filter

Bits 11:10 IC4PSC: Input capture 4 prescaler

Bits 9:8 CC4S: Capture/Compare 4 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC4 channel is configured as output

01: CC4 channel is configured as input, IC4 is mapped on TI4

10: CC4 channel is configured as input, IC4 is mapped on TI3

11: CC4 channel is configured as input, IC4 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC4S bits are writable only when the channel is OFF (CC4E = '0' in TIMx_CCER).

Bits 7:4 IC3F: Input capture 3 filter

Bits 3:2 IC3PSC: Input capture 3 prescaler

Bits 1:0 CC3S: Capture/compare 3 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC3 channel is configured as output

01: CC3 channel is configured as input, IC3 is mapped on TI3

10: CC3 channel is configured as input, IC3 is mapped on TI4

11: CC3 channel is configured as input, IC3 is mapped on TRC. This mode is working only if an internal trigger input is selected through TS bit (TIMx_SMCR register)

Note: CC3S bits are writable only when the channel is OFF (CC3E = '0' in TIMx_CCER).

16.4.9 TIM2 capture/compare enable register (TIMx_CCER)

Address offset: 0x20

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
CC4NPResCC4PCC4ECC3NPResCC3PCC3ECC2NPResCC2PCC2ECC1NPResCC1PCC1E
rwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, always read as 0.

Bit 15 CC4NP: Capture/compare 4 output complementary polarity. Refer to CC1P description.

Bit 14 Reserved, always read as 0.

Bit 13 CC4P: Capture/Compare 4 output polarity
refer to CC1P description

Bit 12 CC4E: Capture/Compare 4 output enable
refer to CC1E description

Bit 11 CC3NP: Capture/compare 3 complementary output polarity. Refer to CC1P description.

Bit 10 Reserved, always read as 0.

Table 81. Output control bits for OCx channels

CCxE bitOCx output state
0Output disabled (not driven by the timer: Hi-Z)
OCx=0
1OCxREF + Polarity
OCx=OCxREF xor CCxP

16.4.10 TIM2 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000 0000

31302928272625242322212019181716
UIFCPYRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
r
1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw
Bit 31 UIFCPY : UIF copy

This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in the TIMxCR1 is reset, bit 31 is reserved and read at 0.

Bits 30:16 Reserved, always read as 0.

Bits 15:0 CNT[15:0] : Counter value

16.4.11 TIM2 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 PSC[15:0] : Prescaler value

The counter clock frequency (CK_CNT) is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

16.4.12 TIM2 auto-reload register (TIMx_ARR)

Address offset: 0x2C

Reset value: 0x0000 FFFF

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 ARR[15:0]: Prescaler value

ARR is the value to be loaded in the actual auto-reload register.

Refer to the Section 16.3.1: Time-base unit on page 308 for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

16.4.13 TIM2 repetition counter register (TIMx_RCR)

Address offset: 0x30

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
REP[7:0]
rrrrrrrrrwrwrwrwrwrwrwrw

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:0 REP[7:0]: Repetition counter value

These bits allow the user to set-up the update rate of the compare registers (i.e. periodic transfers from preload to active registers) when preload registers are enable, as well as the update interrupt generation rate, if this interrupt is enable.

Each time the REP_CNT related downcounter reaches zero, an update event is generated and it restarts counting from REP value. As REP_CNT is reloaded with REP value only at the repetition update event U_RC, any write to the TIMx_RCR register is not taken in account until the next repetition update event.

It means in PWM mode (REP+1) corresponds to:

the number of PWM periods in edge-aligned mode

the number of half PWM period in center-aligned mode.

16.4.14 TIM2 capture/compare register 1 (TIMx_CCR1)

Address offset: 0x34

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
CCR1[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 CCR1[15:0]: Capture/Compare 1 value

If channel CC1 is configured as output:

CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value). It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs. The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on OC1 output.

If channel CC1 is configured as input:

CCR1 is the counter value transferred by the last input capture 1 event (IC1).

ST logo
ST logo

16.4.15 TIM2 capture/compare register 2 (TIMx_CCR2)

Address offset: 0x38

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
CCR2[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 CCR2[15:0]: Capture/Compare 2 value

If channel CC2 is configured as output:

CCR2 is the value to be loaded in the actual capture/compare 2 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR2 register (bit OC2PE). Else the preload value is copied in the active capture/compare 2 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC2 output.

If channel CC2 is configured as input:

CCR2 is the counter value transferred by the last input capture 2 event (IC2).

16.4.16 TIM2 capture/compare register 3 (TIMx_CCR3)

Address offset: 0x3C

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
CCR3[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 CCR3[15:0]: Capture/Compare value

If channel CC3 is configured as output:

CCR3 is the value to be loaded in the actual capture/compare 3 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR3 register (bit OC3PE). Else the preload value is copied in the active capture/compare 3 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signalled on OC3 output.

If channel CC3 is configured as input:

CCR3 is the counter value transferred by the last input capture 3 event (IC3).

16.4.17 TIM2 capture/compare register 4 (TIMx_CCR4)

Address offset: 0x40

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
CCR4[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 CCR4[15:0]: Capture/Compare value

If channel CC4 is configured as output:

CCR4 is the value to be loaded in the actual capture/compare 4 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR4 register (bit OC4PE). Else the preload value is copied in the active capture/compare 4 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on OC4 output.

If channel CC4 is configured as input:

CCR4 is the counter value transferred by the last input capture 4 event (IC4).

16.4.18 TIM2 DMA control register (TIM2_DCR)

Address offset: 0x48

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
ResResResDBL[4:0]ResResResDBA[4:0]
rwrwrwrwrwrwrwrwrwrw

Bits 31:13 Reserved, must be kept at reset value.

Bits 12:8 DBL[4:0]: DMA burst length

This 5-bit field defines the length of DMA transfers (the timer recognizes a burst transfer when a read or a write access is done to the TIM2_DMAR address), i.e. the number of transfers.

Transfers can be in half-words or in bytes (see example below).

00000: 1 transfer,

00001: 2 transfers,

00010: 3 transfers,

...

10001: 18 transfers.

Bits 7:5 Reserved, must be kept at reset value.

Bits 4:0 DBA[4:0]: DMA base address

This 5-bit field defines the base-address for DMA transfers (when read/write access are done through the TIM2_DMAR address). DBA is defined as an offset starting from the address of the TIM2_CR1 register.

Example:

00000: TIM2_CR1,

00001: TIM2_CR2,

00010: Reserved,

...

Example: Let us consider the following transfer: DBL = 7 transfers and DBA = TIM2_CR1. In this case the transfer is done to/from 7 registers starting from the TIM2_CR1 address.

16.4.19 TIM2 DMA address for full transfer (TIM2_DMAR)

Address offset: 0x4C

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
DMAB[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bits 15:0 DMAB[15:0]: DMA register for burst accesses

A read or write operation to the DMAR register accesses the register located at the address
\((\text{TIM2\_CR1 address}) + (\text{DBA} + \text{DMA index}) \times 4\)

where TIM2_CR1 address is the address of the control register 1, DBA is the DMA base address configured in TIM2_DCR register, DMA index is automatically controlled by the DMA transfer, and ranges from 0 to DBL (DBL configured in TIM2_DCR).

16.4.20 TIM2 input selection register (TIM2_TISEL)

Address offset: 0x68

Reset value: 0x0000 0000

31302928272625242322212019181716
Res.Res.Res.Res.TI4SEL[3:0]Res.Res.Res.Res.TI3SEL[3:0]
rwrwrwrwrwrwrwrw
1514131211109876543210
Res.Res.Res.Res.TI2SEL[3:0]Res.Res.Res.Res.TI1SEL[3:0]
rwrwrwrwrwrwrwrw

Bits 31:28 Reserved, must be kept at reset value.

Bits 27:24 TI4SEL[3:0]: selects TI4[0] to TI4[15] input
0000: TIMx_CH4 input
Others: Reserved

Bits 23:20 Reserved, must be kept at reset value.

Bits 19:16 TI3SEL[3:0]: selects TI3[0] to TI3[15] input
0000: TIMx_CH3 input
Others: Reserved

Bits 15:12 Reserved, must be kept at reset value.

Bits 11:8 TI2SEL[3:0]: selects TI2[0] to TI2[15] input
0000: TIMx_CH2 input
Others: Reserved

Bits 7:4 Reserved, must be kept at reset value.

Bits 3:0 TI1SEL[3:0]: selects TI1[0] to TI1[15] input
0000: TIMx_CH1 input
Others: Reserved

16.4.21 TIM2 register map

TIM2 registers are mapped as 16-bit addressable registers as described in the table below:

Table 82. TIM2 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1ResResResResResResResResResResResResResResResResResResResResUIFREMAResCKD [1:0]ARPECMS [1:0]DIROPMURSUDISCEN
Reset value000000000
0x04TIMx_CR2ResResResResResResResResResResResResResResResResResResResResResResResResTISMMS[2:0]CCDSResResRes
Reset value00000
0x08TIMx_SMCRResResResResResResResResResResTS[4:3]ResResResResSMS[3]ETPECEETPS [1:0]ResResResResResMSMTS[2:0]OCSSSMS[2:0]
Reset value00000000000000000
0x0CTIMx_DIERResResResResResResResResResResResResResResResResResResResResResResResResResTIEResResResResRes
Reset value000000
0x10TIMx_SRResResResResResResResResResResResResResResResResResResResResResResResResResTIFResResResResRes
Reset value000000
0x14TIMx_EGRResResResResResResResResResResResResResResResResResResResResResResResResResTGResResResResRes
Reset value000000
0x18TIMx_CCMR1 Output Compare modeResResResResResResResResResResResResResResResOC2M[3]OC2CEOC2M [2:0]ResResResResResResResOC1CEOC1M [2:0]OC1PEOC1FECC1S [1:0]
Reset value000000000000000
TIMx_CCMR1 Input Capture modeResResResResResResResResResResResResResResResResResResResResResResResResResIC1F[3:0]IC1PSC [1:0]IC1PSC [1:0]CC1S [1:0]
Reset value000000
0x1CTIMx_CCMR2 Output Compare modeResResResResResResResResResResResResResResResOC4M[3]OC4CEOC4M [2:0]ResResResResResResResOC3CEOC3M [2:0]OC3PEOC3FECC3S [1:0]
Reset value000000000000000
TIMx_CCMR2 Input Capture modeResResResResResResResResResResResResResResResResResResResResResResResResResIC3F[3:0]IC3PSC [1:0]IC3PSC [1:0]CC3S [1:0]
Reset value000000
0x20TIMx_CCERResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value
0x24TIMx_CNTUIFCPYResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value0
0x28TIMx_PSCResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value
Table 82. TIM2 register map and reset values (continued)
OffsetRegister313029282726252423222120191817161514131211109876543210
0x2CTIMx_ARRResResResResResResResResResResResResResResResResARR[15:0]
Reset value1111111111111111
0x30TIMx_RCRResResResResResResResResResResResResResResResResResResResResResResResResREP[7:0]
Reset value00000000
0x34TIMx_CCR1ResResResResResResResResResResResResResResResResCCR1[15:0]
Reset value0000000000000000
0x38TIMx_CCR2ResResResResResResResResResResResResResResResResCCR2[15:0]
Reset value0000000000000000
0x3CTIMx_CCR3ResResResResResResResResResResResResResResResResCCR3[15:0]
Reset value0000000000000000
0x40TIMx_CCR4ResResResResResResResResResResResResResResResResCCR4[15:0]
Reset value0000000000000000
0x48TIMx_DCRResResResResResResResResResResResResResResResResResResResDBL[4:0]ResResResDBA[4:0]
Reset value0000000000
0x4CTIMx_DMARResResResResResResResResResResResResResResResResDMAB[15:0]
Reset value0000000000000000
0x68TIMx_TISELResResResResTI4SEL[3:0]ResResResResTI3SEL[3:0]ResResResResTI2SEL[3:0]ResResResResTI1SEL[3:0]
Reset value0000000000000000

Refer to Section 2.2.2: Memory map and register boundary addresses for the register boundary addresses.