21. Inter-integrated circuit (I2C) interface

21.1 Introduction

The I2C (inter-integrated circuit) bus interface handles communications between the microcontroller and the serial I2C bus. It provides multicontroller capability, and controls all I2C bus-specific sequencing, protocol, arbitration and timing. It supports Standard-mode (Sm), Fast-mode (Fm) and Fast-mode Plus (Fm+).

It is also SMBus (system management bus) and PMBus (power management bus) compatible.

DMA can be used to reduce CPU overload.

21.2 I2C main features

The following additional features are also available depending on the product implementation (see Section 21.3: I2C implementation):

Note: For the Fast-Mode Plus mode, it is strongly recommended to use I2C pins mentioned as open-drain capable (embedding a 10ns/50ns filter).

21.3 I2C implementation

This manual describes the full set of features implemented in I2C1.

Table 88. I2C implementation

I2C features(1)I2C1
7-bit addressing modeX
10-bit addressing modeX
Standard-mode (up to 100 kbit/s)X
Fast-mode (up to 400 kbit/s)X
Fast-mode Plus with 20mA output drive I/Os (up to 1 Mbit/s)X
Independent clockX
SMBusX

1. X = supported.

21.4 I2C functional description

In addition to receiving and transmitting data, this interface converts it from serial to parallel format and vice versa. The interrupts are enabled or disabled by software. The interface is connected to the I2C bus by a data pin (SDA) and by a clock pin (SCL). It can be connected with a standard (up to 100 kHz), Fast-mode (up to 400 kHz) or Fast-mode Plus (up to 1 MHz) I2C bus.

This interface can also be connected to a SMBus with the data pin (SDA) and clock pin (SCL).

If SMBus feature is supported: the additional optional SMBus Alert pin (SMBA) is also available.

21.4.1 I2C block diagram

The block diagram of the I2C interface is shown in Figure 93.

Figure 93. I2C block diagram

I2C block diagram showing Data control (Shift register, SMBUS PEC generation / check), Clock control (Master clock generation, Slave clock stretching, SMBus Timeout check), SMBus Alert control & status, Digital/Analog noise filters, GPIO logic, Registers, APB bus, and external pins I2CCLK, PCLK, I2Cx_SDA, I2Cx_SCL, I2Cx_SMBA.

The diagram illustrates the internal architecture of the I2C interface:

MS34452V1b

I2C block diagram showing Data control (Shift register, SMBUS PEC generation / check), Clock control (Master clock generation, Slave clock stretching, SMBus Timeout check), SMBus Alert control & status, Digital/Analog noise filters, GPIO logic, Registers, APB bus, and external pins I2CCLK, PCLK, I2Cx_SDA, I2Cx_SCL, I2Cx_SMBA.

The I2C is clocked by an independent clock source which allows to the I2C to operate independently from the PCLK frequency.

This independent clock source is a fixed 16 MHz clock. Refer to Section 6: Reset and clock controller (RCC) for more details.

I2C I/Os support 20 mA output current drive for Fast-mode Plus operation. This is enabled by setting the driving capability control bits for SCL and SDA in Section 8.2.3: Fast-Mode Plus pin capability control register (I2C_FMP_CTRL).

21.4.2 I2C clock requirements

The I2C kernel is clocked by I2CCLK.

The I2CCLK period \(t_{I2CCLK}\) must respect the following conditions:

\(t_{I2CCLK} < (t_{LOW} - t_{filters}) / 4\) and \(t_{I2CCLK} < t_{HIGH}\)

with:

\(t_{LOW}\): SCL low time and \(t_{HIGH}\): SCL high time

\(t_{filters}\): when enabled, sum of the delays brought by the analog filter and by the digital filter.

Analog filter delay is maximum 260 ns. Digital filter delay is \(DNF \times t_{I2CCLK}\).

The PCLK clock period \(t_{PCLK}\) must respect the following condition:

\(t_{PCLK} < 4/3 t_{SCL}\)

with \(t_{SCL}\): SCL period

21.4.3 Mode selection

The interface can operate in one of the four following modes:

By default, it operates in target mode. The interface automatically switches from target to controller when it generates a START condition, and from controller to target if an arbitration loss or a STOP generation occurs, allowing multicontroller capability.

Communication flow

In Controller mode, the I2C interface initiates a data transfer and generates the clock signal. A serial data transfer always begins with a START condition and ends with a STOP condition. Both START and STOP conditions are generated in controller mode by software.

In Target mode, the interface is capable of recognizing its own addresses (7 or 10-bit), and the General Call address. The General Call address detection can be enabled or disabled by software. The reserved SMBus addresses can also be enabled by software.

Data and addresses are transferred as 8-bit bytes, MSB first. The first byte(s) following the START condition contain the address (one in 7-bit mode, two in 10-bit mode). The address is always transmitted in Controller mode.

A 9th clock pulse follows the 8 clock cycles of a byte transfer, during which the receiver must send an acknowledge bit to the transmitter. Refer to the following figure.

Figure 94. I2 C bus protocol Timing diagram for the I2C bus protocol showing SDA and SCL signals.

The diagram illustrates the I2C bus protocol timing. It features two horizontal signal lines: SDA (Serial Data) and SCL (Serial Clock). The SCL signal is a periodic square wave. The SDA signal carries data bits, with the first bit labeled 'MSB' and the final bit labeled 'ACK'. The diagram shows the first two bits, followed by a dashed line indicating omitted bits, and then bits 8 and 9. A 'Start condition' is marked at the beginning, where SDA transitions from high to low while SCL is high. A 'Stop condition' is marked at the end, where SDA transitions from low to high while SCL is high. Vertical lines with double-headed arrows indicate the timing relationship between the SDA and SCL signals during data transmission.

Timing diagram for the I2C bus protocol showing SDA and SCL signals.

Acknowledge can be enabled or disabled by software. The I2C interface addresses can be selected by software.

21.4.4 I2C initialization

Enabling and disabling the peripheral

The I2C peripheral clock must be configured and enabled in the clock controller (refer to Section 6: Reset and clock controller (RCC)).

Then the I2C can be enabled by setting the PE bit in the I2C_CR1 register.

When the I2C is disabled (PE=0), the I2C performs a software reset. Refer to Section 21.4.5: Software reset for more details.

Noise filters

Before you enable the I2C peripheral by setting the PE bit in I2C_CR1 register, you must configure the noise filters, if needed. By default, an analog noise filter is present on the SDA and SCL inputs. This analog filter is compliant with the I2C specification which requires the suppression of spikes with a pulse width up to 50 ns in Fast-mode and Fast-mode Plus. You can disable this analog filter by setting the ANFOFF bit, and/or select a digital filter by configuring the DNF[3:0] bit in the I2C_CR1 register.

When the digital filter is enabled, the level of the SCL or the SDA line is internally changed only if it remains stable for more than DNF x I2CCLK periods. This allows to suppress spikes with a programmable length of 1 to 15 I2CCLK periods.

Caution: Changing the filter configuration is not allowed when the I2C is enabled.

I2C timings

The timings must be configured in order to guarantee a correct data hold and setup time, used in controller and target modes. This is done by programming the PRESC[3:0], SCLDEL[3:0] and SDADEL[3:0] bits in the I2C_TIMINGR register.

Figure 95. Setup and hold timings

Figure 95. Setup and hold timings diagram containing two sub-diagrams: DATA HOLD TIME and DATA SETUP TIME. The DATA HOLD TIME diagram shows SCL falling edge internal detection, tSYNC1 delay, SDADEL delay, SDA output delay, and Data hold time tHD;DAT. The DATA SETUP TIME diagram shows SCLDEL with SCL stretched low by the slave transmitter, and Data setup time tSU;DAT.
Figure 95. Setup and hold timings diagram containing two sub-diagrams: DATA HOLD TIME and DATA SETUP TIME. The DATA HOLD TIME diagram shows SCL falling edge internal detection, tSYNC1 delay, SDADEL delay, SDA output delay, and Data hold time tHD;DAT. The DATA SETUP TIME diagram shows SCLDEL with SCL stretched low by the slave transmitter, and Data setup time tSU;DAT.

The total SDA output delay is:

\(t_{\text{SYNC1}} + \{[\text{SDADEL} \times (\text{PRESC}+1) + 1] \times t_{\text{I2CCLK}} \}\)

\(t_{SYNC1}\) duration depends on these parameters:

In order to bridge the undefined region of the SCL falling edge, you must program SDADEL in such a way that:

\[\{t_{f(max)} + t_{HD;DAT(min)} - t_{AF(min)} - [(DNF + 3) \times t_{I2CCLK}]\} / \{(PRESC + 1) \times t_{I2CCLK}\} \leq SDADEL\]
\[SDADEL \leq \{t_{HD;DAT(max)} - t_{AF(max)} - [(DNF + 4) \times t_{I2CCLK}]\} / \{(PRESC + 1) \times t_{I2CCLK}\}\]

Note: \(t_{AF(min)} / t_{AF(max)}\) are part of the equation only when the analog filter is enabled. Refer to the datasheet [1] for \(t_{AF}\) values.

The maximum \(t_{HD;DAT}\) could be 3.45 μs, 0.9 μs and 0.45 μs for Standard-mode, Fast-mode and Fast-mode Plus, but must be less than the maximum of \(t_{VD;DAT}\) by a transition time. This maximum must only be met if the device does not stretch the LOW period (\(t_{LOW}\)) of the SCL signal. If the clock stretches the SCL, the data must be valid by the set-up time before it releases the clock.

The SDA rising edge is usually the worst case, so in this case the previous equation becomes:

\[SDADEL \leq \{t_{VD;DAT(max)} - t_r(max) - 260\text{ ns} - [(DNF + 4) \times t_{I2CCLK}]\} / \{(PRESC + 1) \times t_{I2CCLK}\}.\]

Note: This condition can be violated when NOSTRETCH=0, because the device stretches SCL low to guarantee the set-up time, according to the SCLDEL value.

Refer to Table 89: I2C-SMBUS specification data setup and hold times for \(t_f\), \(t_r\), \(t_{HD;DAT}\) and \(t_{VD;DAT}\) standard values.

In order to bridge the undefined region of the SDA transition (rising edge usually worst case), you must program SCLDEL in such a way that:

\[\{[t_r(max) + t_{SU;DAT(min)}] / [(PRESC + 1) \times t_{I2CCLK}]\} - 1 \leq SCLDEL\]

Refer to Table 89: I2C-SMBUS specification data setup and hold times for \(t_r\) and \(t_{SU;DAT}\) standard values.

The SDA and SCL transition time values to be used are the ones in the application. Using the maximum values from the standard increases the constraints for the SDADEL and SCLDEL calculation, but ensures the feature whatever the application.

Table 89. I2 C-SMBUS specification data setup and hold times
SymbolParameterStandard-mode (Sm)Fast-mode (Fm)Fast-mode Plus (Fm+)SMBUSUnit
Min.MaxMin.MaxMin.MaxMin.Max
tHD;DATData hold time0-0-0-0.3-μs
tVD;DATData valid time-3.45-0.9-0.45--
tSU;DATData setup time250-10050250ns
trRise time of both SDA and SCL signals-1000300-120-1000
tfFall time of both SDA and SCL signals-300300-120-300

Additionally, in controller mode, the SCL clock high and low levels must be configured by programming the PRESC[3:0], SCLH[7:0] and SCLL[7:0] bits in the I2C_TIMINGR register.

Refer to section 21.4.4: I2C initialization for more details.

Caution: Changing the timing configuration is not allowed when the I2C is enabled.

The I2C target NOSTRETCH mode must also be configured before enabling the peripheral. Refer to I2C target initialization for more details.

Caution: Changing the NOSTRETCH configuration is not allowed when the I2C is enabled.

Figure 96. I2C initialization flowchart

I2C initialization flowchart showing the sequence of steps: Initial settings, Clear PE bit in I2C_CR1, Configure ANFOFF and DNF[3:0] in I2C_CR1, Configure PRESC[3:0], SDADEL[3:0], SCLDEL[3:0], SCLH[7:0], SCLL[7:0] in I2C_TIMINGR, Configure NOSTRETCH in I2C_CR1, Set PE bit in I2C_CR1, and End.
graph TD
    A([Initial settings]) --> B[Clear PE bit in I2C_CR1]
    B --> C[Configure ANFOFF and DNF[3:0] in I2C_CR1]
    C --> D["Configure PRESC[3:0],
SDADEL[3:0], SCLDEL[3:0], SCLH[7:0],
SCLL[7:0] in I2C_TIMINGR"] D --> E[Configure NOSTRETCH in I2C_CR1] E --> F[Set PE bit in I2C_CR1] F --> G([End])
I2C initialization flowchart showing the sequence of steps: Initial settings, Clear PE bit in I2C_CR1, Configure ANFOFF and DNF[3:0] in I2C_CR1, Configure PRESC[3:0], SDADEL[3:0], SCLDEL[3:0], SCLH[7:0], SCLL[7:0] in I2C_TIMINGR, Configure NOSTRETCH in I2C_CR1, Set PE bit in I2C_CR1, and End.

21.4.5 Software reset

A software reset can be performed by clearing the PE bit in the I2C_CR1 register. In that case I2C lines SCL and SDA are released. Internal states machines are reset and communication control bits, as well as status bits come back to their reset value. The configuration registers are not impacted.

Here is the list of impacted register bits:

  1. 1. I2C_CR2 register: START, STOP, NACK
  2. 2. I2C_ISR register: BUSY, TXE, TXIS, RXNE, ADDR, NACKF, TCR, TC, STOPF, BERR, ARLO, OVR

and in addition when the SMBus feature is supported:

  1. 1. I2C_CR2 register: PECBYTE
  2. 2. I2C_ISR register: PECERR, TIMEOUT, ALERT

PE must be kept low during at least 3 APB clock cycles in order to perform the software reset. This is ensured by writing the following software sequence: - Write PE=0 - Check PE=0 - Write PE=1.

21.4.6 Data transfer

The data transfer is managed through transmit and receive data registers and a shift register.

Reception

The SDA input fills the shift register. After the 8th SCL pulse (when the complete data byte is received), the shift register is copied into I2C_RXDR register if it is empty (RXNE=0). If RXNE=1, meaning that the previous received data byte has not yet been read, the SCL line is stretched low until I2C_RXDR is read. The stretch is inserted between the 8th and 9th SCL pulse (before the Acknowledge pulse).

Figure 97. Data reception

Timing diagram for I2C data reception showing SCL, Shift register, RXNE, and I2C_RXDR signals.

The diagram illustrates the data reception process. The SCL signal shows a series of pulses. A blue horizontal line indicates an SCL stretch between the 8th and 9th pulses. The Shift register contains data segments: 'xx', 'data1', 'xx', 'data2', and 'xx'. The RXNE signal is low when data is available in the shift register and high when it is empty. Arrows labeled 'rd data0' and 'rd data1' point from the shift register to the I2C_RXDR register. The I2C_RXDR register contains 'data0', 'data1', and 'data2'. Two ACK pulses are shown on the SCL line, one after the 8th pulse and another after the 16th pulse. A legend indicates that the blue line represents an SCL stretch.

Timing diagram for I2C data reception showing SCL, Shift register, RXNE, and I2C_RXDR signals.

MS19848V1

Transmission

If the I2C_TXDR register is not empty (TXE=0), its content is copied into the shift register after the 9th SCL pulse (the Acknowledge pulse). Then the shift register content is shifted out on SDA line. If TXE=1, meaning that no data is written yet in I2C_TXDR, SCL line is stretched low until I2C_TXDR is written. The stretch is done after the 9th SCL pulse.

Figure 98. Data transmission

Timing diagram for I2C data transmission showing SCL, Shift register, TXE, and I2C_TXDR signals.

The diagram illustrates the data transmission process. The SCL signal shows a series of pulses. A blue horizontal line indicates an SCL stretch between the 9th and 10th pulses. The Shift register contains data segments: 'xx', 'data1', 'xx', 'data2', and 'xx'. The TXE signal is high when the I2C_TXDR register is empty and low when it contains data. Arrows labeled 'wr data1' and 'wr data2' point from the I2C_TXDR register to the shift register. The I2C_TXDR register contains 'data0', 'data1', and 'data2'. Two ACK pulses are shown on the SCL line, one after the 9th pulse and another after the 17th pulse. A legend indicates that the blue line represents an SCL stretch.

Timing diagram for I2C data transmission showing SCL, Shift register, TXE, and I2C_TXDR signals.

MS19849V1

Hardware transfer management

The I2C has a byte counter embedded in hardware in order to manage byte transfer and to close the communication in various modes such as:

The byte counter is always used in controller mode. By default it is disabled in target mode, but it can be enabled by software by setting the SBC (Target Byte Control) bit in the I2C_CR2 register.

The number of bytes to be transferred is programmed in the NBYTES[7:0] bit field in the I2C_CR2 register. If the number of bytes to be transferred (NBYTES) is greater than 255, or if a receiver wants to control the acknowledge value of a received data byte, the reload mode must be selected by setting the RELOAD bit in the I2C_CR2 register. In this mode, TCR flag is set when the number of bytes programmed in NBYTES has been transferred, and an interrupt is generated if TCIE is set. SCL is stretched as long as TCR flag is set. TCR is cleared by software when NBYTES is written to a non-zero value.

When the NBYTES counter is reloaded with the last number of bytes, RELOAD bit must be cleared.

When RELOAD=0 in controller mode, the counter can be used in 2 modes:

Caution: The AUTOEND bit has no effect when the RELOAD bit is set.

Table 90. I2C configuration table

FunctionSBC bitRELOAD bitAUTOEND bit
Controller Tx/Rx NBYTES + STOPx01
Controller Tx/Rx + NBYTES + RESTARTx00
Target Tx/Rx
all received bytes ACKed
0xx
Target Rx with ACK control11x

21.4.7 I2C target mode

I2C target initialization

In order to work in target mode, you must enable at least one target address. Two registers I2C_OAR1 and I2C_OAR2 are available in order to program the target own addresses OA1 and OA2.

When the I2C is selected by one of its enabled addresses, the ADDR interrupt status flag is set, and an interrupt is generated if the ADDRIE bit is set.

By default, the target uses its clock stretching capability, which means that it stretches the SCL signal at low level when needed, in order to perform software actions. If the controller does not support clock stretching, the I2C must be configured with NOSTRETCH=1 in the I2C_CR1 register.

After receiving an ADDR interrupt, if several addresses are enabled you must read the ADDCODE[6:0] bits in the I2C_ISR register in order to check which address matched. DIR flag must also be checked in order to know the transfer direction.

Target clock stretching (NOSTRETCH = 0)

In default mode, the I2C target stretches the SCL clock in the following situations:

is cleared (TXE=1). This stretch is released when the data is written to the I2C_TXDR register.

Target without clock stretching (NOSTRETCH = 1)

When NOSTRETCH = 1 in the I2C_CR1 register, the I2C target does not stretch the SCL signal.

Target byte control mode

In order to allow byte ACK control in target reception mode, Target Byte Control mode must be enabled by setting the SBC bit in the I2C_CR1 register. This is required to be compliant with SMBus standards.

Reload mode must be selected in order to allow byte ACK control in target reception mode (RELOAD=1). To get control of each byte, NBYTES must be initialized to 0x1 in the ADDR interrupt subroutine, and reloaded to 0x1 after each received byte. When the byte is received, the TCR bit is set, stretching the SCL signal low between the 8th and 9th SCL pulses. You can read the data from the I2C_RXDR register, and then decide to acknowledge it or not by configuring the ACK bit in the I2C_CR2 register. The SCL stretch is released by programming NBYTES to a non-zero value: the acknowledge or not-acknowledge is sent and next byte can be received.

NBYTES can be loaded with a value greater than 0x1, and in this case, the reception flow is continuous during NBYTES data reception.

Note: The SBC bit must be configured when the I2C is disabled, or when the target is not addressed, or when ADDR=1.

The RELOAD bit value can be changed when ADDR=1, or when TCR=1.

Caution: Target Byte Control mode is not compatible with NOSTRETCH mode. Setting SBC when NOSTRETCH=1 is not allowed.

Figure 99. Target initialization flowchart

Flowchart for Target initialization. The process starts with 'Target initialization' (oval), followed by 'Initial settings' (rectangle), 'Clear OA1EN and OA2EN in I2C_OAR1/I2C_OAR2' (rectangle), 'Configure OA1[9:0], OA1MODE, OA1EN, OA2[6:0], OA2MSK[2:0], OA2EN, and GCEN' (rectangle), 'Optional: Configure SBC in I2C_CR1(1)' (rectangle), 'Enable interrupts and/or DMA in I2C_CR1' (rectangle), and ends with 'End' (oval).
graph TD
    A([Target initialization]) --> B[Initial settings]
    B --> C[Clear OA1EN and OA2EN in I2C_OAR1/I2C_OAR2]
    C --> D[Configure OA1[9:0], OA1MODE, OA1EN, OA2[6:0], OA2MSK[2:0], OA2EN, and GCEN]
    D --> E[Optional: Configure SBC in I2C_CR1(1)]
    E --> F[Enable interrupts and/or DMA in I2C_CR1]
    F --> G([End])
  

MSv19850V4

Flowchart for Target initialization. The process starts with 'Target initialization' (oval), followed by 'Initial settings' (rectangle), 'Clear OA1EN and OA2EN in I2C_OAR1/I2C_OAR2' (rectangle), 'Configure OA1[9:0], OA1MODE, OA1EN, OA2[6:0], OA2MSK[2:0], OA2EN, and GCEN' (rectangle), 'Optional: Configure SBC in I2C_CR1(1)' (rectangle), 'Enable interrupts and/or DMA in I2C_CR1' (rectangle), and ends with 'End' (oval).

1. SBC must be set to support SMBus features.

Target transmitter

A transmit interrupt status (TXIS) is generated when the I2C_TXDR register becomes empty. An interrupt is generated if the TXIE bit is set in the I2C_CR1 register.

The TXIS bit is cleared when the I2C_TXDR register is written with the next data byte to be transmitted.

When a NACK is received, the NACKF bit is set in the I2C_ISR register and an interrupt is generated if the NACKIE bit is set in the I2C_CR1 register. The target automatically releases the SCL and SDA lines in order to let the controller perform a STOP or a RESTART condition. The TXIS bit is not set when a NACK is received.

When a STOP is received and the STOPIE bit is set in the I2C_CR1 register, the STOPF flag is set in the I2C_ISR register and an interrupt is generated. In most applications, the SBC bit is usually programmed to '0'. In this case, If TXE = 0 when the target address is received (ADDR=1), you can choose either to send the content of the I2C_TXDR register as the first data byte, or to flush the I2C_TXDR register by setting the TXE bit in order to program a new data byte.

In Target Byte Control mode (SBC=1), the number of bytes to be transmitted must be programmed in NBYTES in the address match interrupt subroutine (ADDR=1). In this case, the number of TXIS events during the transfer corresponds to the value programmed in NBYTES.

Caution: When NOSTRETCH=1, the SCL clock is not stretched while the ADDR flag is set, so you cannot flush the I2C_TXDR register content in the ADDR subroutine, in order to program

the first data byte. The first data byte to be sent must be previously programmed in the I2C_TXDR register:

If STOPF is still set when the first data transmission starts, an underrun error is generated (the OVR flag is set).

If you need a TXIS event, (Transmit Interrupt or Transmit DMA request), you must set the TXIS bit in addition to the TXE bit, in order to generate a TXIS event.

Figure 100. Transfer sequence flowchart for I2C target transmitter, NOSTRETCH=0

Flowchart for I2C target transmitter transfer sequence. It starts with 'Target transmission' leading to 'Target initialization'. A loop follows: 'I2C_ISR.ADDR = 1?' (No loop back, Yes to 'Read ADDCODE and DIR in I2C_ISR...'). Then 'I2C_ISR.TXIS = 1?' (No loop back, Yes to 'Write I2C_TXDR.TXDATA'). A vertical double-headed arrow on the right is labeled 'SCL stretched'.
graph TD
    Start([Target transmission]) --> Init[Target initialization]
    Init --> AddrCheck{I2C_ISR.ADDR = 1?}
    AddrCheck -- No --> AddrCheck
    AddrCheck -- Yes --> ReadRegs[Read ADDCODE and DIR in I2C_ISR
Optional: Set I2C_ISR.TXE = 1
Set I2C_ICR.ADDRCF] ReadRegs --> TxIsCheck{I2C_ISR.TXIS = 1?} TxIsCheck -- No --> TxIsCheck TxIsCheck -- Yes --> WriteData[Write I2C_TXDR.TXDATA] WriteData --> TxIsCheck

MSv19851V3

Flowchart for I2C target transmitter transfer sequence. It starts with 'Target transmission' leading to 'Target initialization'. A loop follows: 'I2C_ISR.ADDR = 1?' (No loop back, Yes to 'Read ADDCODE and DIR in I2C_ISR...'). Then 'I2C_ISR.TXIS = 1?' (No loop back, Yes to 'Write I2C_TXDR.TXDATA'). A vertical double-headed arrow on the right is labeled 'SCL stretched'.

Figure 101. Transfer sequence flowchart for I2C target transmitter, NOSTRETCH=1

Flowchart for I2C target transmitter transfer sequence. It starts with 'Target transmission' leading to 'Target initialization'. From there, it branches into two parallel loops. The left loop checks 'I2C_ISR.TXIS = 1?'; if 'Yes', it performs 'Write I2C_TXDR.TXDATA' and loops back. If 'No', it proceeds to the right loop. The right loop checks 'I2C_ISR.STOPF = 1?'; if 'No', it loops back to the check. If 'Yes', it performs an optional step: 'Set I2C_ISR.TXE = 1 and I2C_ISR.TXIS=1', followed by 'Set I2C_ICR.STOPCF'.
graph TD; Start([Target transmission]) --> Init[Target initialization]; Init --> Join(( )); Join --> LCheck{I2C_ISR.TXIS = 1?}; Join --> RCheck{I2C_ISR.STOPF = 1?}; LCheck -- Yes --> LWrite[Write I2C_TXDR.TXDATA]; LWrite --> LCheck; LCheck -- No --> RCheck; RCheck -- No --> RCheck; RCheck -- Yes --> ROptional[Optional: Set I2C_ISR.TXE = 1 and I2C_ISR.TXIS=1]; ROptional --> RSet[Set I2C_ICR.STOPCF];

MSv19852V3

Flowchart for I2C target transmitter transfer sequence. It starts with 'Target transmission' leading to 'Target initialization'. From there, it branches into two parallel loops. The left loop checks 'I2C_ISR.TXIS = 1?'; if 'Yes', it performs 'Write I2C_TXDR.TXDATA' and loops back. If 'No', it proceeds to the right loop. The right loop checks 'I2C_ISR.STOPF = 1?'; if 'No', it loops back to the check. If 'Yes', it performs an optional step: 'Set I2C_ISR.TXE = 1 and I2C_ISR.TXIS=1', followed by 'Set I2C_ICR.STOPCF'.

Figure 102. Transfer bus diagrams for I2C target transmitter

Example I2C target transmitter 3 bytes with 1st data flushed, NOSTRETCH=0:

Timing diagram for I2C target transmitter with 1st data flushed, NOSTRETCH=0 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV5 and TXE signal line.
Timing diagram for I2C target transmitter with 1st data flushed, NOSTRETCH=0 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV5 and TXE signal line.

legend:
□ transmission
□ reception
— SCL stretch

Example I2C target transmitter 3 bytes without 1st data flush, NOSTRETCH=0:

Timing diagram for I2C target transmitter without 1st data flush, NOSTRETCH=0 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV4 and TXE signal line.
Timing diagram for I2C target transmitter without 1st data flush, NOSTRETCH=0 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV4 and TXE signal line.

legend :
□ transmission
□ reception
— SCL stretch

Example I2C target transmitter 3 bytes, NOSTRETCH=1:

Timing diagram for I2C target transmitter with 3 bytes, NOSTRETCH=1 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV5 and TXE signal line.
Timing diagram for I2C target transmitter with 3 bytes, NOSTRETCH=1 showing bus states S, Address, A, data1, A, data2, A, data3, NA, P with event markers EV1 to EV5 and TXE signal line.

legend:
□ transmission
□ reception
— SCL stretch

MSv19853V3

Target receiver

RXNE is set in I2C_ISR when the I2C_RXDR is full, and generates an interrupt if RXIE is set in I2C_CR1. RXNE is cleared when I2C_RXDR is read.

When a STOP is received and STOPIE is set in I2C_CR1, STOPF is set in I2C_ISR and an interrupt is generated.

Figure 103. Transfer sequence flowchart for target receiver with NOSTRETCH=0

Flowchart for target receiver transfer sequence. It starts with 'Target reception' (oval), followed by 'Target initialization' (rectangle). A decision diamond asks 'I2C_ISR.ADDR = 1?'. If 'No', it loops back to the entry point before the decision. If 'Yes', it proceeds to a rectangle: 'Read ADDCODE and DIR in I2C_ISR' and 'Set I2C_ICR.ADDRCF'. To the right of this rectangle is a vertical double-headed arrow labeled 'SCL stretched'. Below this is another decision diamond: 'I2C_ISR.RXNE = 1?'. If 'No', it loops back to the entry point before the second decision. If 'Yes', it proceeds to a rectangle: 'Write I2C_RXDR.RXDATA'. From this final rectangle, the flow loops back to the entry point before the second decision.
graph TD; Start([Target reception]) --> Init[Target initialization]; Init --> AddrCheck{I2C_ISR.ADDR = 1?}; AddrCheck -- No --> AddrCheck; AddrCheck -- Yes --> ReadSet[Read ADDCODE and DIR in I2C_ISR
Set I2C_ICR.ADDRCF]; ReadSet --> RXNECheck{I2C_ISR.RXNE = 1?}; RXNECheck -- No --> RXNECheck; RXNECheck -- Yes --> WriteData[Write I2C_RXDR.RXDATA]; WriteData --> RXNECheck;

MSv19855V3

Flowchart for target receiver transfer sequence. It starts with 'Target reception' (oval), followed by 'Target initialization' (rectangle). A decision diamond asks 'I2C_ISR.ADDR = 1?'. If 'No', it loops back to the entry point before the decision. If 'Yes', it proceeds to a rectangle: 'Read ADDCODE and DIR in I2C_ISR' and 'Set I2C_ICR.ADDRCF'. To the right of this rectangle is a vertical double-headed arrow labeled 'SCL stretched'. Below this is another decision diamond: 'I2C_ISR.RXNE = 1?'. If 'No', it loops back to the entry point before the second decision. If 'Yes', it proceeds to a rectangle: 'Write I2C_RXDR.RXDATA'. From this final rectangle, the flow loops back to the entry point before the second decision.

Figure 104. Transfer sequence flowchart for target receiver with NOSTRETCH=1

Transfer sequence flowchart for target receiver with NOSTRETCH=1
graph TD
    A([Target reception]) --> B[Target initialization]
    B --> C{I2C_ISR.RXNE
=1?}
    C -- Yes --> D[Read I2C_RXDR.RXDATA]
    D --> C
    C -- No --> E{I2C_ISR.STOPF
=1?}
    E -- No --> E
    E -- Yes --> F[Set I2C_ICR.STOPCF]

MSv19856V3

Transfer sequence flowchart for target receiver with NOSTRETCH=1

Figure 105. Transfer bus diagrams for I2C target receiver

Timing diagram for Example I2C target receiver 3 bytes, NOSTRETCH = 0, showing ADDR at EV1, RXNE at EV2, EV3, EV4 with data1, data2, data3 reception and SCL stretching during address and data phases. Timing diagram for Example I2C target receiver 3 bytes, NOSTRETCH = 1, showing RXNE at EV1, EV2, EV3 with data 1, data 2, data 3 reception without clock stretching.

Example I2C target receiver 3 bytes, NOSTRETCH = 0:

Legend
□ Transmission
■ Reception
— SCL stretch

EV1: ADDR ISR: check ADDCODE and DIR, set ADDRCF
EV2: RXNE ISR: rd data1
EV3: RXNE ISR: rd data2
EV4: RXNE ISR: rd data3

Example I2C target receiver 3 bytes, NOSTRETCH = 1:

Legend
□ Transmission
■ Reception
— SCL stretch

EV1: RXNE ISR: rd data1
EV2: RXNE ISR: rd data2
EV3: RXNE ISR: rd data3

MSv19857V5

Timing diagram for Example I2C target receiver 3 bytes, NOSTRETCH = 0, showing ADDR at EV1, RXNE at EV2, EV3, EV4 with data1, data2, data3 reception and SCL stretching during address and data phases. Timing diagram for Example I2C target receiver 3 bytes, NOSTRETCH = 1, showing RXNE at EV1, EV2, EV3 with data 1, data 2, data 3 reception without clock stretching.

21.4.8 I2C controller mode

I2C controller initialization

Before enabling the peripheral, the I2C controller clock must be configured by setting the SCLH and SCLL bits in the I2C_TIMINGR register.

A clock synchronization mechanism is implemented in order to support multi-controller environment and target clock stretching.

In order to allow clock synchronization:

The I2C detects its own SCL low level after a \(t_{SYNC1}\) delay depending on the SCL falling edge, SCL input noise filters (analog + digital) and SCL synchronization to the I2CxCLK clock. The I2C releases SCL to high level once the SCLL counter reaches the value programmed in the SCLL[7:0] bits in the I2C_TIMINGR register.

The I2C detects its own SCL high level after a \(t_{SYNC2}\) delay depending on the SCL rising edge, SCL input noise filters (analog + digital) and SCL synchronization to I2CxCLK clock. The I2C ties SCL to low level once the SCLH counter is reached reaches the value programmed in the SCLH[7:0] bits in the I2C_TIMINGR register.

Consequently the controller clock period is:

\[t_{SCL} = t_{SYNC1} + t_{SYNC2} + \{[(SCLH+1) + (SCLL+1)] \times (PRESC+1) \times t_{I2CCLK}\}\]

The duration of \(t_{SYNC1}\) depends on these parameters:

The duration of \(t_{SYNC2}\) depends on these parameters:

Figure 106. Controller clock generation Timing diagram for SCL controller clock generation showing SCL signal transitions, synchronization pulses tSYNC1 and tSYNC2, counter start labels, and SCLH / SCLL periods. Timing diagram for SCL controller clock synchronization showing interaction between controller and other device driving SCL low.

SCL controller clock generation

SCL controller clock synchronization

MSv19858V2

Timing diagram for SCL controller clock generation showing SCL signal transitions, synchronization pulses tSYNC1 and tSYNC2, counter start labels, and SCLH / SCLL periods. Timing diagram for SCL controller clock synchronization showing interaction between controller and other device driving SCL low.

Caution: In order to be I2C or SMBus compliant, the controller clock must respect the timings given below:

Table 91. I2C-SMBUS specification clock timings
SymbolParameterStandard-mode (Sm)Fast-mode (Fm)Fast-mode Plus (Fm+)SMBUSUnit
MinMaxMinMaxMinMaxMinMax
fSCLSCL clock frequency-100-400-1000-100kHz
tHD:STAHold time (repeated) START condition4.0-0.6-0.26-4.0-µs
tSU:STASet-up time for a repeated START condition4.7-0.6-0.26-4.7-µs
tSU:STOSet-up time for STOP condition4.0-0.6-0.26-4.0-µs
Table 91. I2 C-SMBUS specification clock timings (continued)
SymbolParameterStandard-mode (Sm)Fast-mode (Fm)Fast-mode Plus (Fm+)SMBUSUnit
MinMaxMinMaxMinMaxMinMax
tBUFBus free time between a STOP and START condition4.7-1.3-0.5-4.7-µs
tLOWLow period of the SCL clock4.7-1.3-0.5-4.7-µs
tHIGHPeriod of the SCL clock4.0-0.6-0.26-4.050µs
trRise time of both SDA and SCL signals-1000-300-120-1000ns
tfFall time of both SDA and SCL signals-300-300-120-300ns

Note: SCLL is also used to generate the tBUF and tSU:STA timings.

SCLH is also used to generate the tHD:STA and tSU:STO timings.

Refer to Section 21.4.9: I2C_TIMINGR register configuration examples for examples of I2C_TIMINGR settings vs. I2CCLK frequency.

Controller communication initialization (address phase)

In order to initiate the communication, you must program the following parameters for the addressed target in the I2C_CR2 register:

You must then set the START bit in I2C_CR2 register. Changing all the above bits is not allowed when START bit is set.

Then the controller automatically sends the START condition followed by the target address as soon as it detects that the bus is free (BUSY = 0) and after a delay of tBUF.

In case of an arbitration loss, the controller automatically switches back to target mode and can acknowledge its own address if it is addressed as a target.

Note: The START bit is reset by hardware when the target address has been sent on the bus, whatever the received acknowledge value. The START bit is also reset by hardware if an arbitration loss occurs. If the I2C is addressed as a target (ADDR=1) while the START bit is set, the I2C switches to target mode and the START bit is cleared when the ADDRCF bit is set.

Note: The same procedure is applied for a Repeated Start condition. In this case BUSY=1.

Figure 107. Controller initialization flowchart

Flowchart for Controller initialization. The process starts with 'Controller initialization' (oval), followed by 'Initial settings' (rectangle), then 'Enable interrupts and/or DMA in I2C_CR1' (rectangle), and finally 'End' (oval).
graph TD
    A([Controller initialization]) --> B[Initial settings]
    B --> C[Enable interrupts and/or DMA in I2C_CR1]
    C --> D([End])
  

MSv19859V3

Flowchart for Controller initialization. The process starts with 'Controller initialization' (oval), followed by 'Initial settings' (rectangle), then 'Enable interrupts and/or DMA in I2C_CR1' (rectangle), and finally 'End' (oval).

Initialization of a controller receiver addressing a 10-bit address target

Figure 108. 10-bit address read access with HEAD10R=1

Diagram showing the sequence of I2C transactions for a 10-bit address read access with HEAD10R=1. It consists of two parts: 'Write' and 'Read'. The 'Write' part starts with a START bit (S), followed by the 1st 7 bits of the target address, a R/W bit (0), an ACK (A), the 2nd byte of the target address, another ACK (A), and then a series of DATA and ACK (A) pairs. The 'Read' part starts with a RESTART bit (Sr), followed by the 1st 7 bits of the target address, a R/W bit (1), an ACK (A), a DATA byte, an ACK (A), and finally a DATA byte, a NOT ACK (A-bar), and a STOP (P) condition.

MSv19823V2

Diagram showing the sequence of I2C transactions for a 10-bit address read access with HEAD10R=1. It consists of two parts: 'Write' and 'Read'. The 'Write' part starts with a START bit (S), followed by the 1st 7 bits of the target address, a R/W bit (0), an ACK (A), the 2nd byte of the target address, another ACK (A), and then a series of DATA and ACK (A) pairs. The 'Read' part starts with a RESTART bit (Sr), followed by the 1st 7 bits of the target address, a R/W bit (1), an ACK (A), a DATA byte, an ACK (A), and finally a DATA byte, a NOT ACK (A-bar), and a STOP (P) condition.

Controller transmitter

In the case of a write transfer, the TXIS flag is set after each byte transmission, after the 9th SCL pulse when an ACK is received.

A TXIS event generates an interrupt if the TXIE bit is set in the I2C_CR1 register. The flag is cleared when the I2C_TXDR register is written with the next data byte to be transmitted.

The number of TXIS events during the transfer corresponds to the value programmed in NBYTES[7:0]. If the total number of data bytes to be sent is greater than 255, reload mode must be selected by setting the RELOAD bit in the I2C_CR2 register. In this case, when

NBYTES data have been transferred, the TCR flag is set and the SCL line is stretched low until NBYTES[7:0] is written to a non-zero value.

The TXIS flag is not set when a NACK is received.

Figure 109. Transfer sequence flowchart for I2C controller transmitter for N≤255 bytes

Flowchart for I2C controller transmitter transfer sequence. It starts with 'Controller transmission' leading to 'Controller initialization', then a setup block for NBYTES, AUTOEND, target address, and I2C_CR2.START. The main loop checks for NACKF (ends if Yes) or TXIS (writes to TXDR if Yes). After writing, it checks if NBYTES are transmitted. If not, it loops back. If yes, it checks TC. If TC is Yes, it sets I2C_CR2.START for the next transfer and loops back. If TC is No, it ends.
graph TD; Start([Controller transmission]) --> Init[Controller initialization]; Init --> Setup["NBYTES = N
AUTOEND = 0 for RESTART; 1 for STOP
Configure target address
Set I2C_CR2.START"]; Setup --> Join(( )); Join --> NACKF{I2C_ISR.NACKF = 1?}; Join --> TXIS{I2C_ISR.TXIS = 1?}; NACKF -- Yes --> End1([End]); NACKF -- No --> Join; TXIS -- No --> Join; TXIS -- Yes --> Write[Write I2C_TXDR]; Write --> NBYTESTrans{NBYTES transmitted?}; NBYTESTrans -- No --> Join; NBYTESTrans -- Yes --> TC{I2C_ISR.TC = 1?}; TC -- Yes --> Next["Set I2C_CR2.START with
target address NBYTES
..."]; TC -- No --> End2([End]); Next --> Join;

MSv19860V3

Flowchart for I2C controller transmitter transfer sequence. It starts with 'Controller transmission' leading to 'Controller initialization', then a setup block for NBYTES, AUTOEND, target address, and I2C_CR2.START. The main loop checks for NACKF (ends if Yes) or TXIS (writes to TXDR if Yes). After writing, it checks if NBYTES are transmitted. If not, it loops back. If yes, it checks TC. If TC is Yes, it sets I2C_CR2.START for the next transfer and loops back. If TC is No, it ends.

Figure 110. Transfer sequence flowchart for I2C controller transmitter for N>255 bytes

Flowchart for I2C controller transmitter for N>255 bytes. The process starts with 'Controller transmission' and 'Controller initialization'. It then sets NBYTES = 0xFF, N = N-255, RELOAD = 1, configures the target address, and sets I2C_CR2.START. The flow then enters a loop checking for I2C_ISR.NACKF and I2C_ISR.TXIS. If NACKF is set, it ends. If TXIS is set, it writes to I2C_TXDR and checks if NBYTES are transmitted. If not, it loops back. If transmitted, it checks I2C_ISR.TC. If TC is set, it sets I2C_CR2.START with the target address and NBYTES, then checks I2C_ISR.TCR. If TCR is set, it updates NBYTES and N based on whether N < 256, and loops back. If TCR is not set, it ends. If TC is not set, it also ends.
graph TD; Start([Controller transmission]) --> Init[Controller initialization]; Init --> Init2[NBYTES = 0xFF; N=N-255
RELOAD = 1
Configure target address
Set I2C_CR2.START]; Init2 --> J1(( )); J1 --> NACKF{I2C_ISR.NACKF = 1?}; J1 --> TXIS{I2C_ISR.TXIS = 1?}; NACKF -- Yes --> End1([End]); NACKF -- No --> J1; TXIS -- No --> End2([End]); TXIS -- Yes --> WriteTXDR[Write I2C_TXDR]; WriteTXDR --> NBYTESTrans{NBYTES transmitted?}; NBYTESTrans -- No --> End2; NBYTESTrans -- Yes --> TC{I2C_ISR.TC = 1?}; TC -- Yes --> SetCR2[Set I2C_CR2.START with target address NBYTES ...]; SetCR2 -.-> TCR{I2C_ISR.TCR = 1?}; TCR -- Yes --> UpdateN[NBYTES = N; N = 0; RELOAD = 0
AUTOEND = 0 for RESTART; 1 for STOP
ELSE
NBYTES = 0xFF; N = N-255
RELOAD = 1]; UpdateN --> J1; TCR -- No --> End3([End]); TC -- No --> End3;

MSv19861V4

Flowchart for I2C controller transmitter for N>255 bytes. The process starts with 'Controller transmission' and 'Controller initialization'. It then sets NBYTES = 0xFF, N = N-255, RELOAD = 1, configures the target address, and sets I2C_CR2.START. The flow then enters a loop checking for I2C_ISR.NACKF and I2C_ISR.TXIS. If NACKF is set, it ends. If TXIS is set, it writes to I2C_TXDR and checks if NBYTES are transmitted. If not, it loops back. If transmitted, it checks I2C_ISR.TC. If TC is set, it sets I2C_CR2.START with the target address and NBYTES, then checks I2C_ISR.TCR. If TCR is set, it updates NBYTES and N based on whether N < 256, and loops back. If TCR is not set, it ends. If TC is not set, it also ends.
Figure 111. Transfer bus diagrams for I2C controller transmitter

Example I2C controller transmitter 2 bytes, automatic end mode (STOP)

Timing diagram for I2C transmitter in automatic end mode (STOP). The diagram shows a sequence of events: S (START), Address, A (ACK), data1, A (ACK), data2, A (ACK), and P (STOP). Arrows indicate INIT at S, EV1 and EV2 at the ACKs, and TXIS at the start of data1 and data2. The TXE signal is high during transmission and low during reception. The NBYTES register is set to 2. A legend indicates that white boxes are transmission, yellow boxes are reception, and blue lines are SCL stretches.

legend:
□ transmission
□ reception
— SCL stretch

INIT: program target address, program NBYTES = 2, AUTOEND = 1, set START
EV1: TXIS ISR: wr data1
EV2: TXIS ISR: wr data2

Timing diagram for I2C transmitter in automatic end mode (STOP). The diagram shows a sequence of events: S (START), Address, A (ACK), data1, A (ACK), data2, A (ACK), and P (STOP). Arrows indicate INIT at S, EV1 and EV2 at the ACKs, and TXIS at the start of data1 and data2. The TXE signal is high during transmission and low during reception. The NBYTES register is set to 2. A legend indicates that white boxes are transmission, yellow boxes are reception, and blue lines are SCL stretches.

Example I2C controller transmitter 2 bytes, software end mode (RESTART)

Timing diagram for I2C transmitter in software end mode (RESTART). The diagram shows a sequence of events: S (START), Address, A (ACK), data1, A (ACK), data2, A (ACK), ReS (RESTART), and Address. Arrows indicate INIT at S, EV1 and EV2 at the ACKs, and EV3 at the RESTART. The TXE signal is high during transmission and low during reception. The NBYTES register is set to 2. A legend indicates that white boxes are transmission, yellow boxes are reception, and blue lines are SCL stretches.

legend:
□ transmission
□ reception
— SCL stretch

INIT: program target address, program NBYTES = 2, AUTOEND = 0, set START
EV1: TXIS ISR: wr data1
EV2: TXIS ISR: wr data2
EV3: TC ISR: program target address, program NBYTES = N, set START

Timing diagram for I2C transmitter in software end mode (RESTART). The diagram shows a sequence of events: S (START), Address, A (ACK), data1, A (ACK), data2, A (ACK), ReS (RESTART), and Address. Arrows indicate INIT at S, EV1 and EV2 at the ACKs, and EV3 at the RESTART. The TXE signal is high during transmission and low during reception. The NBYTES register is set to 2. A legend indicates that white boxes are transmission, yellow boxes are reception, and blue lines are SCL stretches.

MSv19862V3

Controller receiver

In the case of a read transfer, the RXNE flag is set after each byte reception, after the 8th SCL pulse. An RXNE event generates an interrupt if the RXIE bit is set in the I2C_CR1 register. The flag is cleared when I2C_RXDR is read.

If the total number of data bytes to be received is greater than 255, reload mode must be selected by setting the RELOAD bit in the I2C_CR2 register. In this case, when NBYTES[7:0] data have been transferred, the TCR flag is set and the SCL line is stretched low until NBYTES[7:0] is written to a non-zero value.

Figure 112. Transfer sequence flowchart for I2C controller receiver for N≤255 bytes

Flowchart for I2C controller receiver transfer sequence. It starts with 'Controller reception' (oval), followed by 'Controller initialization' (rectangle). Then a process block: 'NBYTES = N', 'AUTOEND = 0 for RESTART; 1 for STOP', 'Configure target address', 'Set I2C_CR2.START'. A loop begins with decision 'I2C_ISR.RXNE = 1?'. If 'No', it loops back. If 'Yes', it proceeds to 'Read I2C_RXDR', then decision 'NBYTES received?'. If 'No', it loops back. If 'Yes', it proceeds to decision 'I2C_ISR.TC = 1?'. If 'No', it goes to 'End' (oval). If 'Yes', it proceeds to 'Set I2C_CR2.START with target address NBYTES ...' (rectangle) and loops back to the first decision. A vertical dashed line is below this last process block.
graph TD; A([Controller reception]) --> B[Controller initialization]; B --> C["NBYTES = N
AUTOEND = 0 for RESTART; 1 for STOP
Configure target address
Set I2C_CR2.START"]; C --> D{I2C_ISR.RXNE = 1?}; D -- No --> E; D -- Yes --> F[Read I2C_RXDR]; F --> G{NBYTES received?}; G -- No --> E; G -- Yes --> H{I2C_ISR.TC = 1?}; H -- No --> I([End]); H -- Yes --> J["Set I2C_CR2.START with
target address NBYTES
..."]; J --> E; E(( )); style E fill:none,stroke:none;

MSv19863V3

Flowchart for I2C controller receiver transfer sequence. It starts with 'Controller reception' (oval), followed by 'Controller initialization' (rectangle). Then a process block: 'NBYTES = N', 'AUTOEND = 0 for RESTART; 1 for STOP', 'Configure target address', 'Set I2C_CR2.START'. A loop begins with decision 'I2C_ISR.RXNE = 1?'. If 'No', it loops back. If 'Yes', it proceeds to 'Read I2C_RXDR', then decision 'NBYTES received?'. If 'No', it loops back. If 'Yes', it proceeds to decision 'I2C_ISR.TC = 1?'. If 'No', it goes to 'End' (oval). If 'Yes', it proceeds to 'Set I2C_CR2.START with target address NBYTES ...' (rectangle) and loops back to the first decision. A vertical dashed line is below this last process block.

Figure 113. Transfer sequence flowchart for I2C controller receiver for N >255 bytes

Flowchart for I2C controller receiver for N > 255 bytes. The process starts with 'Controller reception' and 'Controller initialization'. It then sets NBYTES = 0xFF, N = N - 255, RELOAD = 1, configures the target address, and sets I2C_CR2.START. The main loop checks for I2C_ISR.RXNE = 1? If no, it loops back. If yes, it reads I2C_RXDR and checks if NBYTES received?. If no, it loops back. If yes, it checks I2C_ISR.TC = 1?. If yes, it sets I2C_CR2.START with target address NBYTES and loops back. If no, it checks I2C_ISR.TCR = 1?. If yes, it updates NBYTES, N, and RELOAD based on N and the transfer mode (RESTART or STOP). If no, it ends the process.
graph TD; Start([Controller reception]) --> Init[Controller initialization]; Init --> Init2[NBYTES = 0xFF; N=N-255
RELOAD =1
Configure target address
Set I2C_CR2.START]; Init2 --> RXNE{I2C_ISR.RXNE =1?}; RXNE -- No --> LoopBack(( )); LoopBack --> RXNE; RXNE -- Yes --> Read[Read I2C_RXDR]; Read --> Received{NBYTES received?}; Received -- No --> LoopBack; Received -- Yes --> TC{I2C_ISR.TC = 1?}; TC -- Yes --> SetStart[Set I2C_CR2.START with target address NBYTES ...]; SetStart --> LoopBack; TC -- No --> TCR{I2C_ISR.TCR = 1?}; TCR -- Yes --> Update[IF N< 256
NBYTES =N; N=0;RELOAD=0
AUTOEND=0 for RESTART; 1 for STOP
ELSE
NBYTES =0xFF;N=N-255
RELOAD=1]; Update --> LoopBack; TCR -- No --> End([End]);

MSv19864V3

Flowchart for I2C controller receiver for N > 255 bytes. The process starts with 'Controller reception' and 'Controller initialization'. It then sets NBYTES = 0xFF, N = N - 255, RELOAD = 1, configures the target address, and sets I2C_CR2.START. The main loop checks for I2C_ISR.RXNE = 1? If no, it loops back. If yes, it reads I2C_RXDR and checks if NBYTES received?. If no, it loops back. If yes, it checks I2C_ISR.TC = 1?. If yes, it sets I2C_CR2.START with target address NBYTES and loops back. If no, it checks I2C_ISR.TCR = 1?. If yes, it updates NBYTES, N, and RELOAD based on N and the transfer mode (RESTART or STOP). If no, it ends the process.

Figure 114. Transfer bus diagrams for I2C controller receiver

Example I2C controller receiver 2 bytes, automatic end mode (STOP)

I2C bus diagram for automatic end mode (STOP) showing transmission and reception phases with RXNE and EV1/EV2 interrupts.

The diagram illustrates an I2C bus transaction in automatic end mode (STOP). The bus sequence consists of:

Interrupts are indicated by arrows: INIT at the start of the address transmission, EV1 at the end of the first data byte reception, and EV2 at the end of the second data byte reception. Below the bus, the NBYTES register is shown with the value 2.

I2C bus diagram for automatic end mode (STOP) showing transmission and reception phases with RXNE and EV1/EV2 interrupts.

INIT: program target address, program NBYTES = 2, AUTOEND=1, set START
EV1: RXNE ISR: rd data1
EV2: RXNE ISR: rd data2

Example I2C controller receiver 2 bytes, software end mode (RESTART)

I2C bus diagram for software end mode (RESTART) showing a sequence of receptions and a restart condition.

The diagram illustrates an I2C bus transaction in software end mode (RESTART). The bus sequence consists of:

Interrupts are indicated by arrows: INIT at the start of the first address transmission, EV1 at the end of the first data byte reception, and EV2 at the end of the second data byte reception. A third interrupt TC (Transfer Complete) is shown at the end of the second reception phase. A blue line indicates an SCL stretch during the transition to the restart condition. Below the bus, the NBYTES register is shown with the value 2 for the first part and N for the subsequent part.

I2C bus diagram for software end mode (RESTART) showing a sequence of receptions and a restart condition.

INIT: program target address, program NBYTES = 2, AUTOEND=0, set START
EV1: RXNE ISR: rd data1
EV2: RXNE ISR: read data2
EV3: TC ISR: program target address, program NBYTES = N, set START

MSv19865V2

21.4.9 I2C_TIMINGR register configuration examples

The tables below provide examples of how to program the I2C_TIMINGR to obtain timings compliant with the I2C specification.

Table 92. Examples of timings settings for \(f_{I2CCLK} = 16\) MHz

ParameterStandard-mode (Sm)Fast-mode (Fm)Fast-mode Plus (Fm+)
10 kHz100 kHz400 kHz1000 kHz
PRESC3310
SCLL0xC70x130x90x4
\(t_{SCLL}\)\(200 \times 250 \text{ ns} = 50 \text{ } \mu\text{s}\)\(20 \times 250 \text{ ns} = 5.0 \text{ } \mu\text{s}\)\(10 \times 125 \text{ ns} = 1250 \text{ ns}\)\(5 \times 62.5 \text{ ns} = 312.5 \text{ ns}\)
SCLH0xC30xF0x30x2
\(t_{SCLH}\)\(196 \times 250 \text{ ns} = 49 \text{ } \mu\text{s}\)\(16 \times 250 \text{ ns} = 4.0 \text{ } \mu\text{s}\)4 × 125 ns = 500 ns\(3 \times 62.5 \text{ ns} = 187.5 \text{ ns}\)
\(t_{SCL}^{(1)}\)\(\sim 100 \text{ } \mu\text{s}^{(2)}\)\(\sim 10 \text{ } \mu\text{s}^{(2)}\)\(\sim 2500 \text{ ns}^{(3)}\)\(\sim 1000 \text{ ns}^{(4)}\)
SDADEL0x20x20x20x0
\(t_{SDADEL}\)2 × 250 ns = 500 ns2 × 250 ns = 500 ns2 × 125 ns = 250 ns0 ns
SCLDEL0x40x40x30x2
\(t_{SCLDEL}\)\(5 \times 250 \text{ ns} = 1250 \text{ ns}\)\(5 \times 250 \text{ ns} = 1250 \text{ ns}\)4 × 125 ns = 500 ns\(3 \times 62.5 \text{ ns} = 187.5 \text{ ns}\)
  1. 1. SCL period \(t_{SCL}\) is greater than \(t_{SCLL} + t_{SCLH}\) due to SCL internal detection delay. Values provided for \(t_{SCL}\) are examples only.
  2. 2. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 250 \text{ ns}\). Example with \(t_{SYNC1} + t_{SYNC2} = 1000 \text{ ns}\)
  3. 3. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 250 \text{ ns}\). Example with \(t_{SYNC1} + t_{SYNC2} = 750 \text{ ns}\)
  4. 4. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 250 \text{ ns}\). Example with \(t_{SYNC1} + t_{SYNC2} = 500 \text{ ns}\)

21.4.10 SMBus specific features

Table 93. Examples of timings settings for \(f_{I2CCLK} = 48\) MHz

ParameterStandard-mode (Sm)Fast-mode (Fm)Fast-mode Plus (Fm+)
10 kHz100 kHz400 kHz1000 kHz
PRESC0xB0xB55
SCLL0xC70x130x90x3
\(t_{SCLL}\)200 × 250 ns = 50 μs20 × 250 ns = 5.0 μs10 × 125 ns = 1250 ns4 × 125 ns = 500 ns
SCLH0xC30xF0x30x1
\(t_{SCLH}\)196 × 250 ns = 49 μs16 × 250 ns = 4.0 μs4 × 125 ns = 500 ns2 × 125 ns = 250 ns
\(t_{SCL}^{(1)}\)~100 μs(2)~10 μs(2)~2500 ns(3)~875 ns(4)
SDADEL0x20x20x30x0
\(t_{SDADEL}\)2 × 250 ns = 500 ns2 × 250 ns = 500 ns3 × 125 ns = 375 ns0 ns
SCLDEL0x40x40x30x1
\(t_{SCLDEL}\)5 × 250 ns = 1250 ns5 × 250 ns = 1250 ns4 × 125 ns = 500 ns2 × 125 ns = 250 ns
  1. 1. The SCL period \(t_{SCL}\) is greater than \(t_{SCLL} + t_{SCLH}\) due to the SCL internal detection delay. Values provided for \(t_{SCL}\) are only examples.
  2. 2. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 83.3\) ns. Example with \(t_{SYNC1} + t_{SYNC2} = 1000\) ns
  3. 3. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 83.3\) ns. Example with \(t_{SYNC1} + t_{SYNC2} = 750\) ns
  4. 4. \(t_{SYNC1} + t_{SYNC2}\) minimum value is \(4 \times t_{I2CCLK} = 83.3\) ns. Example with \(t_{SYNC1} + t_{SYNC2} = 250\) ns

This section is relevant only when SMBus feature is supported. Refer to Section 21.3: I2C implementation.

Introduction

The System Management Bus (SMBus) is a two-wire interface through which various devices can communicate with each other and with the rest of the system. It is based on I2C principles of operation. SMBus provides a control bus for system and power management related tasks.

This peripheral is compatible with the SMBUS specification rev 2.0 (http://smbus.org).

The System Management Bus Specification refers to three types of devices.

This peripheral can be configured as controller or target device, and also as a host.

SMBUS is based on I2C specification rev 2.1.

Bus protocols

There are eleven possible command protocols for any given device. A device may use any or all of the eleven protocols to communicate. The protocols are Quick Command, Send Byte, Receive Byte, Write Byte, Write Word, Read Byte, Read Word, Process Call, Block Read, Block Write and Block Write-Block Read Process Call. These protocols should be implemented by the user software.

For more details of these protocols, refer to SMBus specification version 2.0 (http://smbus.org).

Address resolution protocol (ARP)

SMBus target address conflicts can be resolved by dynamically assigning a new unique address to each target device. In order to provide a mechanism to isolate each device for the purpose of address assignment each device must implement a unique device identifier (UDID). This 128-bit number is implemented by software.

This peripheral supports the Address Resolution Protocol (ARP). The SMBus Device Default Address (0b1100 001) is enabled by setting SMBDEN bit in I2C_CR1 register. The ARP commands should be implemented by the user software.

Arbitration is also performed in target mode for ARP support.

For more details of the SMBus Address Resolution Protocol, refer to SMBus specification version 2.0 (http://smbus.org).

Received Command and Data acknowledge control

A SMBus receiver must be able to NACK each received command or data. In order to allow the ACK control in target mode, the Target Byte Control mode must be enabled by setting SBC bit in I2C_CR1 register. Refer to SMBus target mode on page 491 section for more details.

Host Notify protocol

This peripheral supports the Host Notify protocol by setting the SMBHEN bit in the I2C_CR1 register. In this case the host acknowledges the SMBus Host address (0b0001 000).

When this protocol is used, the device acts as a controller and the host as a target.

SMBus alert

The SMBus ALERT optional signal is supported. A target-only device can signal the host through the SMBALERT# pin that it wants to talk. The host processes the interrupt and simultaneously accesses all SMBALERT# devices through the Alert Response Address (0b0001 100). Only the device(s) which pulled SMBALERT# low acknowledges the Alert Response Address.

When configured as a target device(SMBHEN=0), the SMBA pin is pulled low by setting the ALERTEN bit in the I2C_CR1 register. The Alert Response Address is enabled at the same time.

When configured as a host (SMBHEN=1), the ALERT flag is set in the I2C_ISR register when a falling edge is detected on the SMBA pin and ALERTEN=1. An interrupt is

generated if the ERRIE bit is set in the I2C_CR1 register. When ALERTEN=0, the ALERT line is considered high even if the external SMBA pin is low.

If the SMBus ALERT pin is not needed, the SMBA pin can be used as a standard GPIO if ALERTEN=0.

Packet error checking

A packet error checking mechanism has been introduced in the SMBus specification to improve reliability and communication robustness. Packet Error Checking is implemented by appending a Packet Error Code (PEC) at the end of each message transfer. The PEC is calculated by using the C(x) = x₈+x²+x+1 CRC-8 polynomial on all the message bytes (including addresses and read/write bits).

The peripheral embeds a hardware PEC calculator and allows to send a Not Acknowledge automatically when the received byte does not match with the hardware calculated PEC.

Timeouts

This peripheral embeds hardware timers in order to be compliant with the 3 timeouts defined in SMBus specification version 2.0.

Table 94. SMBus timeout specifications

SymbolParameterLimitsUnit
MinMax
\(t_{\text{TIMEOUT}}\)Detect clock low timeout2535ms
\(t_{\text{LOW:SEXT}}^{(1)}\)Cumulative clock low extend time (target device)-25ms
\(t_{\text{LOW:MEXT}}^{(2)}\)Cumulative clock low extend time (controller device)-10ms
  1. 1. \(t_{\text{LOW:SEXT}}\) is the cumulative time a given target device is allowed to extend the clock cycles in one message from the initial START to the STOP. It is possible that, another target device or the controller also extends the clock causing the combined clock low extend time to be greater than \(t_{\text{LOW:SEXT}}\). Therefore, this parameter is measured with the target device as the sole target of a full-speed controller.
  2. 2. \(t_{\text{LOW:MEXT}}\) is the cumulative time a controller device is allowed to extend its clock cycles within each byte of a message as defined from START-to-ACK, ACK-to-ACK, or ACK-to-STOP. It is possible that a target device or another controller also extends the clock causing the combined clock low time to be greater than \(t_{\text{LOW:MEXT}}\) on a given byte. Therefore, this parameter is measured with a full speed target device as the sole target of the controller.

Figure 115. Timeout intervals for \(t_{\text{LOW:SEXT}}\), \(t_{\text{LOW:MEXT}}\)

Timing diagram for SMBCLK and SMBDAT signals. The diagram shows the relationship between the clock signal (SMBCLK) and the data signal (SMBDAT) during a low state. It includes timing parameters such as tLOW:SEXT, tLOW:MEXT, and ClkAck. The diagram is divided into three sections by vertical dashed lines, each showing a full cycle of the SMBCLK signal and the corresponding SMBDAT signal. The SMBCLK signal is a square wave, and the SMBDAT signal is a square wave that is sampled on the falling edge of the SMBCLK signal. The timing parameters are defined as follows: tLOW:SEXT is the total time from the start of the first SMBCLK cycle to the end of the third SMBCLK cycle. tLOW:MEXT is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle. ClkAck is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle.

Timing diagram for SMBCLK and SMBDAT signals. The diagram shows the relationship between the clock signal (SMBCLK) and the data signal (SMBDAT) during a low state. It includes timing parameters such as \(t_{LOW:SEXT}\), \(t_{LOW:MEXT}\), and \(Clk_{Ack}\). The diagram is divided into three sections by vertical dashed lines, each showing a full cycle of the SMBCLK signal and the corresponding SMBDAT signal. The SMBCLK signal is a square wave, and the SMBDAT signal is a square wave that is sampled on the falling edge of the SMBCLK signal. The timing parameters are defined as follows: \(t_{LOW:SEXT}\) is the total time from the start of the first SMBCLK cycle to the end of the third SMBCLK cycle. \(t_{LOW:MEXT}\) is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle. \(Clk_{Ack}\) is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle.

MS19866V1

Timing diagram for SMBCLK and SMBDAT signals. The diagram shows the relationship between the clock signal (SMBCLK) and the data signal (SMBDAT) during a low state. It includes timing parameters such as tLOW:SEXT, tLOW:MEXT, and ClkAck. The diagram is divided into three sections by vertical dashed lines, each showing a full cycle of the SMBCLK signal and the corresponding SMBDAT signal. The SMBCLK signal is a square wave, and the SMBDAT signal is a square wave that is sampled on the falling edge of the SMBCLK signal. The timing parameters are defined as follows: tLOW:SEXT is the total time from the start of the first SMBCLK cycle to the end of the third SMBCLK cycle. tLOW:MEXT is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle. ClkAck is the time from the start of the first SMBCLK cycle to the start of the second SMBCLK cycle, and from the start of the second SMBCLK cycle to the start of the third SMBCLK cycle.

Bus idle detection

A controller can assume that the bus is free if it detects that the clock and data signals have been high for \(t_{IDLE}\) greater than \(t_{HIGH,MAX}\). (refer to Table 91: I2C-SMBUS specification clock timings)

This timing parameter covers the condition where a controller has been dynamically added to the bus and may not have detected a state transition on the SMBCLK or SMBDAT lines. In this case, the controller must wait long enough to ensure that a transfer is not currently in progress. The peripheral supports a hardware bus idle detection.

21.4.11 SMBus initialization

This section is relevant only when SMBus feature is supported. Refer to Section 21.3: I2C implementation.

In addition to I2C initialization, some other specific initialization must be done in order to perform SMBus communication:

Received Command and Data Acknowledge control (Target mode)

A SMBus receiver must be able to NACK each received command or data. In order to allow ACK control in target mode, the Target Byte Control mode must be enabled by setting the SBC bit in the I2C_CR1 register. Refer to SMBus target mode on page 491 for more details.

Inter-integrated circuit (I2C) interface RM0505

488/925 RM0505 Rev 5

Specific address (Target mode)

The specific SMBus addresses should be enabled if needed. Refer to Bus idle detection on page 488 for more details.

Packet error checking

PEC calculation is enabled by setting the PECEN bit in the I2C_CR1 register. Then the PEC transfer is managed with the help of a hardware byte counter: NBYTES[7:0] in the I2C_CR2 register. The PECEN bit must be configured before enabling the I2C.

The PEC transfer is managed with the hardware byte counter, so the SBC bit must be set when interfacing the SMBus in target mode. The PEC is transferred after NBYTES-1 data have been transferred when the PECBYTE bit is set and the RELOAD bit is cleared. If RELOAD is set, PECBYTE has no effect.

Caution: Changing the PECEN configuration is not allowed when the I2C is enabled.

Table 95. SMBUS with PEC configuration

ModeSBC bitRELOAD bitAUTOEND bitPECBYTE bit
Controller Tx/Rx NBYTES + PEC+ STOPx011
Controller Tx/Rx NBYTES + PEC + ReSTARTx001
Target Tx/Rx with PEC10x1

Timeout detection

The timeout detection is enabled by setting the TIMOUTEN and TEXTEN bits in the I2C_TIMEOUTR register. The timers must be programmed in such a way that they detect a timeout before the maximum time given in the SMBus specification version 2.0.

Caution: Changing the TIMEOUTA[11:0] bits and TIDLE bit configuration is not allowed when the TIMOUTEN bit is set.

\(t_{\text{LOW:MEXT}}\) for a controller. As the standard specifies only a maximum, you can choose the same value for the both.

Then the timer is enabled by setting the TEXTEN bit in the I2C_TIMEOUTR register.

If the SMBus peripheral performs a cumulative SCL stretch for a time greater than \((\text{TIMEOUTB}+1) \times 2048 \times t_{\text{I2CCLK}}\), and in the timeout interval described in Bus idle detection on page 488 section, the TIMEOUT flag is set in the I2C_ISR register.

Refer to Table 97: Example of TIMEOUTB settings

Caution: Changing the TIMEOUTB configuration is not allowed when the TEXTEN bit is set.

Bus Idle detection

In order to enable the \(t_{\text{IDLE}}\) check, the 12-bit TIMEOUTA[11:0] field must be programmed with the timer reload value in order to obtain the \(t_{\text{IDLE}}\) parameter. The TIDLE bit must be configured to '1 in order to detect both SCL and SDA high level timeout.

Then the timer is enabled by setting the TIMOUTEN bit in the I2C_TIMEOUTR register.

If both the SCL and SDA lines remain high for a time greater than \((\text{TIMEOUTA}+1) \times 4 \times t_{\text{I2CCLK}}\), the TIMEOUT flag is set in the I2C_ISR register.

Refer to Table 98: Example of TIMEOUTA settings (max \(t_{\text{IDLE}} = 50 \mu\text{s}\))

Caution: Changing the TIMEOUTA and TIDLE configuration is not allowed when the TIMOUTEN is set.

21.4.12 SMBus: I2C_TIMEOUTR register configuration examples

This section is relevant only when SMBus feature is supported. Refer to Section 21.3: I2C implementation.

Table 96. Examples of TIMEOUTA settings
(max \(t_{\text{TIMEOUT}} = 25 \text{ ms}\))

\(f_{\text{I2CCLK}}\)TIMEOUTA[11:0] bitsTIDLE bitTIMOUTEN bit\(t_{\text{TIMEOUT}}\)
8 MHz0x6101\(98 \times 2048 \times 125 \text{ ns} = 25 \text{ ms}\)
16 MHz0xC301\(196 \times 2048 \times 62.5 \text{ ns} = 25 \text{ ms}\)
48 MHz0x24901\(586 \times 2048 \times 20.08 \text{ ns} = 25 \text{ ms}\)

Table 97. Example of TIMEOUTB settings

\(f_{\text{I2CCLK}}\)TIMEOUTB[11:0] bitsTEXTEN bit\(t_{\text{LOW:EXT}}\)
8 MHz0x1F1\(32 \times 2048 \times 125 \text{ ns} = 8 \text{ ms}\)
16 MHz0x3F1\(64 \times 2048 \times 62.5 \text{ ns} = 8 \text{ ms}\)
48 MHz0xBB1\(188 \times 2048 \times 20.08 \text{ ns} = 8 \text{ ms}\)

Table 98. Example of TIMEOUTA settings
(max \(t_{IDLE}\) = 50 μs)

\(f_{I2CCLK}\)TIMEOUTA[11:0] bitsTIDLE bitTIMEOUTEN bit\(t_{TIDLE}\)
8 MHz0x6311\(100 \times 4 \times 125 \text{ ns} = 50 \mu s\)
16 MHz0xC711\(200 \times 4 \times 62.5 \text{ ns} = 50 \mu s\)
48 MHz0x25711\(600 \times 4 \times 20.08 \text{ ns} = 50 \mu s\)

21.4.13 SMBus target mode

This section is relevant only when SMBus feature is supported. Refer to Section 21.3: I2C implementation.

In addition to 2C target transfer management (refer to Section 21.4.7: I2C target mode) some additional software flowcharts are provided to support SMBus.

SMBus Target transmitter

When the IP is used in SMBus, SBC must be programmed to '1' in order to allow the PEC transmission at the end of the programmed number of data bytes. When the PECBYTE bit is set, the number of bytes programmed in NBYTES[7:0] includes the PEC transmission. In that case the total number of TXIS interrupts is NBYTES-1 and the content of the I2C_PECR register is automatically transmitted if the controller requests an extra byte after the NBYTES-1 data transfer.

Caution: The PECBYTE bit has no effect when the RELOAD bit is set.

Figure 116. Transfer sequence flowchart for SMBus target transmitter N bytes + PEC

Flowchart for SMBus target transmission sequence. It starts with 'SMBus target transmission' leading to 'Target initialization'. A decision diamond 'I2C_ISR.ADDR = 1?' follows; if 'No', it loops back to initialization; if 'Yes', it proceeds to a block: 'Read ADDCODE and DIR in I2C_ISR', 'I2C_CR2.NBYTES = N + 1', 'PECBYTE = 1', and 'Set I2C_ICR.ADDRCF'. A vertical double-headed arrow labeled 'SCL stretched' is next to this block. Then a decision diamond 'I2C_ISR.TXIS = 1?'; if 'Yes', it goes to 'Write I2C_TXDR.TXDATA' and loops back to the TXIS check; if 'No', it exits the loop.
graph TD
    Start([SMBus target transmission]) --> Init[Target initialization]
    Init --> AddrCheck{I2C_ISR.ADDR = 1?}
    AddrCheck -- No --> Init
    AddrCheck -- Yes --> Config["Read ADDCODE and DIR in I2C_ISR
I2C_CR2.NBYTES = N + 1
PECBYTE = 1
Set I2C_ICR.ADDRCF"] Config --> TXISCheck{I2C_ISR.TXIS = 1?} TXISCheck -- Yes --> WriteData[Write I2C_TXDR.TXDATA] WriteData --> TXISCheck TXISCheck -- No --> Exit(( ))

MSv19867V3

Flowchart for SMBus target transmission sequence. It starts with 'SMBus target transmission' leading to 'Target initialization'. A decision diamond 'I2C_ISR.ADDR = 1?' follows; if 'No', it loops back to initialization; if 'Yes', it proceeds to a block: 'Read ADDCODE and DIR in I2C_ISR', 'I2C_CR2.NBYTES = N + 1', 'PECBYTE = 1', and 'Set I2C_ICR.ADDRCF'. A vertical double-headed arrow labeled 'SCL stretched' is next to this block. Then a decision diamond 'I2C_ISR.TXIS = 1?'; if 'Yes', it goes to 'Write I2C_TXDR.TXDATA' and loops back to the TXIS check; if 'No', it exits the loop.

Figure 117. Transfer bus diagrams for SMBus target transmitter (SBC=1)

Bus diagram for SMBus target transmitter showing a sequence of bytes: S (reception), Address (reception), A (transmission), data1 (transmission), A (transmission), data2 (transmission), A (transmission), PEC (transmission), NA (reception), and P (reception). Arrows indicate events: EV1 at the start of the first 'A' byte, EV2 at the start of 'data1', and EV3 at the start of 'data2'. A blue line indicates an SCL stretch during the address reception. Below, a bar labeled 'NBYTES' shows a value of 3 corresponding to the three transmitted data/address bytes.

Example SMBus target transmitter 2 bytes + PEC

legend:
□ transmission
□ reception
— SCL stretch

EV1: ADDR ISR: check ADDCODE, program NBYTES = 3, set PECBYTE, set ADDRCF
EV2: TXIS ISR: wr data1
EV3: TXIS ISR: wr data2

MSv19869V3

Bus diagram for SMBus target transmitter showing a sequence of bytes: S (reception), Address (reception), A (transmission), data1 (transmission), A (transmission), data2 (transmission), A (transmission), PEC (transmission), NA (reception), and P (reception). Arrows indicate events: EV1 at the start of the first 'A' byte, EV2 at the start of 'data1', and EV3 at the start of 'data2'. A blue line indicates an SCL stretch during the address reception. Below, a bar labeled 'NBYTES' shows a value of 3 corresponding to the three transmitted data/address bytes.

SMBus Target receiver

When the I2C is used in SMBus mode, SBC must be programmed to '1' in order to allow the PEC checking at the end of the programmed number of data bytes. In order to allow the ACK control of each byte, the reload mode must be selected (RELOAD=1). Refer to Target byte control mode on page 465 for more details.

In order to check the PEC byte, the RELOAD bit must be cleared and the PECBYTE bit must be set. In this case, after NBYTES-1 data have been received, the next received byte is compared with the internal I2C_PECR register content. A NACK is automatically generated if the comparison does not match, and an ACK is automatically generated if the comparison matches, whatever the ACK bit value. Once the PEC byte is received, it is copied into the I2C_RXDR register like any other data, and the RXNE flag is set.

In the case of a PEC mismatch, the PECERR flag is set and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

If no ACK software control is needed, you can program PECBYTE=1 and, in the same write operation, program NBYTES with the number of bytes to be received in a continuous flow. After NBYTES-1 are received, the next received byte is checked as being the PEC.

Caution: The PECBYTE bit has no effect when the RELOAD bit is set.

Figure 118. Transfer sequence flowchart for SMBus target receiver N Bytes + PEC

Flowchart for SMBus target reception. It starts with 'SMBus target reception' (oval), followed by 'Target initialization' (rectangle). A decision diamond asks 'I2C_ISR.ADDR = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read ADDCODE and DIR in I2C_ISR', 'I2C_CR2.NBYTES = 1, RELOAD = 1', 'PECBYTE = 1', and 'Set I2C_ICR.ADDRCF'. To the right of this box is a vertical double-headed arrow labeled 'SCL stretched'. The flow continues to a decision diamond: 'I2C_ISR.RXNE = 1?' and 'I2C_ISR.TCR = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read I2C_RXDR.RXDATA', 'Program I2C_CR2.NACK = 0', 'I2C_CR2.NBYTES = 1', and 'N = N - 1'. This is followed by a decision diamond 'N = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read I2C_RXDR.RXDATA', 'Program RELOAD = 0', and 'NACK = 0 and NBYTES = 1'. This is followed by a decision diamond 'I2C_ISR.RXNE = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box 'Read I2C_RXDR.RXDATA', and finally to an 'End' oval. The text 'MSv19868V3' is located in the bottom right corner of the flowchart area.
graph TD; Start([SMBus target reception]) --> Init[Target initialization]; Init --> Addr{I2C_ISR.ADDR = 1?}; Addr -- No --> Addr; Addr -- Yes --> ReadAddr[Read ADDCODE and DIR in I2C_ISR
I2C_CR2.NBYTES = 1, RELOAD = 1
PECBYTE = 1
Set I2C_ICR.ADDRCF]; ReadAddr --> RXNE_TCR{I2C_ISR.RXNE = 1?
I2C_ISR.TCR = 1?}; RXNE_TCR -- No --> Addr; RXNE_TCR -- Yes --> ReadData1[Read I2C_RXDR.RXDATA
Program I2C_CR2.NACK = 0
I2C_CR2.NBYTES = 1
N = N - 1]; ReadData1 --> N1{N = 1?}; N1 -- No --> Addr; N1 -- Yes --> ReadData2[Read I2C_RXDR.RXDATA
Program RELOAD = 0
NACK = 0 and NBYTES = 1]; ReadData2 --> RXNE2{I2C_ISR.RXNE = 1?}; RXNE2 -- No --> Addr; RXNE2 -- Yes --> ReadData3[Read I2C_RXDR.RXDATA]; ReadData3 --> End([End]);

MSv19868V3

Flowchart for SMBus target reception. It starts with 'SMBus target reception' (oval), followed by 'Target initialization' (rectangle). A decision diamond asks 'I2C_ISR.ADDR = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read ADDCODE and DIR in I2C_ISR', 'I2C_CR2.NBYTES = 1, RELOAD = 1', 'PECBYTE = 1', and 'Set I2C_ICR.ADDRCF'. To the right of this box is a vertical double-headed arrow labeled 'SCL stretched'. The flow continues to a decision diamond: 'I2C_ISR.RXNE = 1?' and 'I2C_ISR.TCR = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read I2C_RXDR.RXDATA', 'Program I2C_CR2.NACK = 0', 'I2C_CR2.NBYTES = 1', and 'N = N - 1'. This is followed by a decision diamond 'N = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box: 'Read I2C_RXDR.RXDATA', 'Program RELOAD = 0', and 'NACK = 0 and NBYTES = 1'. This is followed by a decision diamond 'I2C_ISR.RXNE = 1?'. If 'No', it loops back to the entry point. If 'Yes', it proceeds to a process box 'Read I2C_RXDR.RXDATA', and finally to an 'End' oval. The text 'MSv19868V3' is located in the bottom right corner of the flowchart area.

Figure 119. Bus transfer diagrams for SMBus target receiver (SBC=1)

Diagram of SMBus target receiver 2 bytes + PEC. The sequence is: S (Start), Address (transmission), A (ACK), data1 (reception), A (ACK), data2 (reception), A (ACK), PEC (reception), A (ACK), P (Stop). Events EV1, EV2, EV3, and EV4 are marked at the start of data1, data2, PEC, and P respectively. NBYTES is set to 3. Legend: transmission (white box), reception (yellow box), SCL stretch (blue line). Diagram of SMBus target receiver 2 bytes + PEC with ACK control. The sequence is: S (Start), Address (transmission), A (ACK), data1 (reception), A (ACK), data2 (reception), A (ACK), PEC (reception), A (ACK), P (Stop). Events EV1, EV2, EV3, and EV4 are marked at the start of data1, data2, PEC, and P respectively. NBYTES is set to 1. Legend: transmission (white box), reception (yellow box), SCL stretch (blue line).

Example SMBus target receiver 2 bytes + PEC

EV1: ADDR ISR: check ADDCODE and DIR, program NBYTES = 3, PECBYTE = 1, RELOAD = 0, set ADDRCF
EV2: RXNE ISR: rd data1
EV3: RXNE ISR: rd data2
EV4: RXNE ISR: rd PEC

Example SMBus target receiver 2 bytes + PEC, with ACK control (RELOAD = 1/0)

EV1: ADDR ISR: check ADDCODE and DIR, program NBYTES = 1, PECBYTE = 1, RELOAD = 1, set ADDRCF
EV2: RXNE-TCR ISR: rd data1, program NACK=0 and NBYTES = 1
EV3: RXNE-TCR ISR: rd data2, program NACK=0, NBYTES = 1 and RELOAD = 0
EV4: RXNE-TCR ISR: rd PEC

MSv19870V3

Diagram of SMBus target receiver 2 bytes + PEC. The sequence is: S (Start), Address (transmission), A (ACK), data1 (reception), A (ACK), data2 (reception), A (ACK), PEC (reception), A (ACK), P (Stop). Events EV1, EV2, EV3, and EV4 are marked at the start of data1, data2, PEC, and P respectively. NBYTES is set to 3. Legend: transmission (white box), reception (yellow box), SCL stretch (blue line). Diagram of SMBus target receiver 2 bytes + PEC with ACK control. The sequence is: S (Start), Address (transmission), A (ACK), data1 (reception), A (ACK), data2 (reception), A (ACK), PEC (reception), A (ACK), P (Stop). Events EV1, EV2, EV3, and EV4 are marked at the start of data1, data2, PEC, and P respectively. NBYTES is set to 1. Legend: transmission (white box), reception (yellow box), SCL stretch (blue line).

This section is relevant only when SMBus feature is supported. Refer to Section 21.3: I2C implementation.

In addition to I2C controller transfer management (refer to Section 21.4.8: I2C controller mode) some additional software flowcharts are provided to support SMBus.

SMBus Controller transmitter

When the SMBus controller wants to transmit the PEC, the PECBYTE bit must be set and the number of bytes must be programmed in the NBYTES[7:0] field, before setting the START bit. In this case the total number of TXIS interrupts is NBYTES-1. So if the PECBYTE bit is set when NBYTES=0x1, the content of the I2C_PECR register is automatically transmitted.

If the SMBus controller wants to send a STOP condition after the PEC, automatic end mode should be selected (AUTOEND=1). In this case, the STOP condition automatically follows the PEC transmission.

When the SMBus controller wants to send a RESTART condition after the PEC, software mode must be selected (AUTOEND=0). In this case, once NBYTES-1 have been transmitted, the I2C_PECR register content is transmitted and the TC flag is set after the PEC transmission, stretching the SCL line low. The RESTART condition must be programmed in the TC interrupt subroutine.

Caution: The PECBYTE bit has no effect when the RELOAD bit is set.

Figure 120. Bus transfer diagrams for SMBus controller transmitter

Two bus transfer diagrams for the SMBus controller transmitter. The top diagram shows 'automatic end mode (STOP)' where NBYTES=3, and the bottom diagram shows 'software end mode (RESTART)' where NBYTES=3 and a RESTART condition follows the PEC. Both diagrams include timing for TXIS, TXE, and NBYTES signals, and a legend for transmission, reception, and SCL stretch.

Example SMBus controller transmitter 2 bytes + PEC, automatic end mode (STOP)

TXIS TXIS
S Address A data1 A data2 A PEC A P
INIT EV1 EV2
TXE
NBYTES xx 3

INIT: program target address, program NBYTES = 3, AUTOEND=1, set PECBYTE, set START
EV1: TXIS ISR: wr data1
EV2: TXIS ISR: wr data2

Example SMBus controller transmitter 2 bytes + PEC, software end mode (RESTART)

TXIS TXIS TC
S Address A data1 A data2 A PEC A RstartAddress
INIT EV1 EV2 EV3
NBYTES xx 3 N

INIT: program target address, program NBYTES = 3, AUTOEND=0, set PECBYTE, set START
EV1: TXIS ISR: wr data1
EV2: TXIS ISR: wr data2
EV3: TC ISR: program target address, program NBYTES = N, set START

MSv19871V3

Two bus transfer diagrams for the SMBus controller transmitter. The top diagram shows 'automatic end mode (STOP)' where NBYTES=3, and the bottom diagram shows 'software end mode (RESTART)' where NBYTES=3 and a RESTART condition follows the PEC. Both diagrams include timing for TXIS, TXE, and NBYTES signals, and a legend for transmission, reception, and SCL stretch.

SMBus Controller receiver

When the SMBus controller wants to receive the PEC followed by a STOP at the end of the transfer, automatic end mode can be selected (AUTOEND=1). The PECBYTE bit must be

set and the target address must be programmed, before setting the START bit. In this case, after NBYTES-1 data have been received, the next received byte is automatically checked versus the I2C_PECR register content. A NACK response is given to the PEC byte, followed by a STOP condition.

When the SMBus controller receiver wants to receive the PEC byte followed by a RESTART condition at the end of the transfer, software mode must be selected (AUTOEND=0). The PECBYTE bit must be set and the target address must be programmed, before setting the START bit. In this case, after NBYTES-1 data have been received, the next received byte is automatically checked versus the I2C_PECR register content. The TC flag is set after the PEC byte reception, stretching the SCL line low. The RESTART condition can be programmed in the TC interrupt subroutine.

Caution: The PECBYTE bit has no effect when the RELOAD bit is set.

Figure 121. Bus transfer diagrams for SMBus controller receiver

Diagram of SMBus controller receiver 2 bytes + PEC, automatic end mode (STOP). The diagram shows a sequence of bytes: S, Address, A, data1, A, data2, A, PEC, NA, P. Arrows indicate events: INIT at S, RXNE at data1, data2, and PEC. A legend shows transmission (white box), reception (yellow box), and SCL stretch (blue line). Below the diagram, NBYTES is shown as xx for the first part and 3 for the second part. Diagram of SMBus controller receiver 2 bytes + PEC, software end mode (RESTART). The diagram shows a sequence of bytes: S, Address, A, data1, A, data2, A, PEC, NA, Restart, Address. Arrows indicate events: INIT at S, RXNE at data1, data2, and PEC, and TC at NA. A legend shows transmission (white box), reception (yellow box), and SCL stretch (blue line). Below the diagram, NBYTES is shown as xx for the first part and N for the second part.

Example SMBus controller receiver 2 bytes + PEC, automatic end mode (STOP)

INIT: program target address, program NBYTES = 3, AUTOEND=1, set PECBYTE, set START
EV1: RXNE ISR: rd data1
EV2: RXNE ISR: rd data2
EV3: RXNE ISR: rd PEC

Example SMBus controller receiver 2 bytes + PEC, software end mode (RESTART)

INIT: program target address, program NBYTES = 3, AUTOEND = 0, set PECBYTE, set START
EV1: RXNE ISR: rd data1
EV2: RXNE ISR: rd data2
EV3: RXNE ISR: read PEC
EV4: TC ISR: program target address, program NBYTES = N, set START

MSv19872V3

Diagram of SMBus controller receiver 2 bytes + PEC, automatic end mode (STOP). The diagram shows a sequence of bytes: S, Address, A, data1, A, data2, A, PEC, NA, P. Arrows indicate events: INIT at S, RXNE at data1, data2, and PEC. A legend shows transmission (white box), reception (yellow box), and SCL stretch (blue line). Below the diagram, NBYTES is shown as xx for the first part and 3 for the second part. Diagram of SMBus controller receiver 2 bytes + PEC, software end mode (RESTART). The diagram shows a sequence of bytes: S, Address, A, data1, A, data2, A, PEC, NA, Restart, Address. Arrows indicate events: INIT at S, RXNE at data1, data2, and PEC, and TC at NA. A legend shows transmission (white box), reception (yellow box), and SCL stretch (blue line). Below the diagram, NBYTES is shown as xx for the first part and N for the second part.

21.4.14 Error conditions

The following are the error conditions which may cause communication to fail.

Bus error (BERR)

A bus error is detected when a START or a STOP condition is detected and is not located after a multiple of 9 SCL clock pulses. A START or a STOP condition is detected when a SDA edge occurs while SCL is high.

The bus error flag is set only if the I2C is involved in the transfer as controller or addressed target (i.e not during the address phase in target mode).

In case of a misplaced START or RESTART detection in target mode, the I2C enters address recognition state like for a correct START condition.

When a bus error is detected, the BERR flag is set in the I2C_ISR register, and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

Arbitration lost (ARLO)

An arbitration loss is detected when a high level is sent on the SDA line, but a low level is sampled on the SCL rising edge.

When an arbitration loss is detected, the ARLO flag is set in the I2C_ISR register, and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

Overrun/underrun error (OVR)

An overrun or underrun error is detected in target mode when NOSTRETCH=1 and:

When an overrun or underrun error is detected, the OVR flag is set in the I2C_ISR register, and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

Packet Error Checking Error (PECERR)

This section is relevant only when the SMBus feature is supported. Refer to Section 21.3: I2C implementation.

A PEC error is detected when the received PEC byte does not match with the I2C_PECR register content. A NACK is automatically sent after the wrong PEC reception.

When a PEC error is detected, the PECERR flag is set in the I2C_ISR register, and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

Timeout Error (TIMEOUT)

This section is relevant only when the SMBus feature is supported. Refer to Section 21.3: I2C implementation.

A timeout error occurs for any of these conditions:

When a timeout violation is detected in controller mode, a STOP condition is automatically sent.

When a timeout violation is detected in target mode, SDA and SCL lines are automatically released.

When a timeout error is detected, the TIMEOUT flag is set in the I2C_ISR register, and an interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

Alert (ALERT)

This section is relevant only when the SMBus feature is supported. Refer to Section 21.3: I2C implementation.

The ALERT flag is set when the I2C interface is configured as a Host (SMBHEN=1), the alert pin detection is enabled (ALERTEN=1) and a falling edge is detected on the SMBA pin. An interrupt is generated if the ERRIE bit is set in the I2C_CR1 register.

21.4.15 DMA requests

Transmission using DMA

DMA (Direct Memory Access) can be enabled for transmission by setting the TXDMAEN bit in the I2C_CR1 register. Data is loaded from an SRAM area configured using the DMA peripheral (see Section 10: DMA controller (DMA)) to the I2C_TXDR register whenever the TXIS bit is set.

Only the data are transferred with DMA.

initialized before setting the START bit. The end of transfer is managed with the NBYTES counter. Refer to Controller transmitter.

Note: If DMA is used for transmission, the TXIE bit does not need to be enabled.

Reception using DMA

DMA (Direct Memory Access) can be enabled for reception by setting the RXDMAEN bit in the I2C_CR1 register. Data is loaded from the I2C_RXDR register to an SRAM area configured using the DMA peripheral (refer to Section 10: DMA controller (DMA)) whenever the RXNE bit is set. Only the data (including PEC) are transferred with DMA.

Note: If DMA is used for reception, the RXIE bit does not need to be enabled.

21.5 I2C interrupts

The table below gives the list of I2C interrupt requests.

Table 99. I2C Interrupt requests

Interrupt eventEvent flagEvent flag/Interrupt clearing methodInterrupt enable control bit
Receive buffer not emptyRXNERead I2C_RXDR registerRXIE
Transmit buffer interrupt statusTXISWrite I2C_TXDR registerTXIE
Stop detection interrupt flagSTOPFWrite STOPCF=1STOPIE
Transfer Complete ReloadTCRWrite I2C_CR2 with NBYTES[7:0] ≠ 0TCIE
Transfer completeTCWrite START=1 or STOP=1

Table 99. I2C Interrupt requests (continued)

Interrupt eventEvent flagEvent flag/Interrupt clearing methodInterrupt enable control bit
Address matchedADDRWrite ADDRCF=1ADDRIE
NACK receptionNACKFWrite NACKCF=1NACKIE
Bus errorBERRWrite BERRCF=1ERRIE
Arbitration lossARLOWrite ARLOCF=1
Overrun/UnderrunOVRWrite OVRCF=1
PEC errorPECERRWrite PECERRCF=1
Timeout/\(t_{LOW}\) errorTIMEOUTWrite TIMEOUTCF=1
SMBus AlertALERTWrite ALERTCF=1

Depending on the product implementation, all these interrupts events can either share the same interrupt vector (I2C global interrupt), or be grouped into 2 interrupt vectors (I2C event interrupt and I2C error interrupt). Refer to Section 2.3.2: Interrupts for details.

In order to enable the I2C interrupts, the following sequence is required:

  1. 1. Configure and enable the I2C IRQ channel in the NVIC.
  2. 2. Configure the I2C to generate interrupts.

Figure 122. I2C interrupt mapping diagram

I2C interrupt mapping diagram showing the logic for generating I2C event, error, and global interrupts.

The diagram illustrates the logic for generating I2C interrupts. It shows the mapping of various interrupt flags to the I2C event interrupt, I2C error interrupt, and the final I2C global interrupt.

I2C event interrupt generation:

I2C error interrupt generation:

I2C global interrupt generation:

I2C interrupt mapping diagram showing the logic for generating I2C event, error, and global interrupts.

21.6 I2C registers

Refer to Section 1.5: Acronyms for a list of abbreviations used in register descriptions.

The peripheral registers are accessed by words (32-bit).

21.6.1 Control register 1 (I2C_CR1)

Address offset: 0x00

Reset value: 0x0000 0000

Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 x PCLK1 + 6 x I2CCLK.

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.PECENALERT ENSMBD ENSMBH ENGCENRes.NOSTR ETCHSBC
rwrwrwrwrwrwrw
1514131211109876543210
RXDMA ENTXDMA ENRes.ANF OFFDNFERRIETCIESTOP IENACK IEADDR IERXIETXIEPE
rwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:24 Reserved, must be kept at reset value.

Bit 23 PECEN: PEC enable

0: PEC calculation disabled

1: PEC calculation enabled

Note: If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 22 ALERTEN: SMBus alert enable

Device mode (SMBHEN=0):

0: Releases SMBA pin high and Alert Response Address Header disabled: 0001100x followed by NACK.

1: Drives SMBA pin low and Alert Response Address Header enables: 0001100x followed by ACK.

Host mode (SMBHEN=1):

0: SMBus Alert pin (SMBA) not supported.

1: SMBus Alert pin (SMBA) supported.

Note: When ALERTEN=0, the SMBA pin can be used as a standard GPIO.

If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 21 SMBDEN: SMBus Device Default address enable

0: Device default address disabled. Address 0b1100001x is NACKed.

1: Device default address enabled. Address 0b1100001x is ACKed.

Note: If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 7 ERRIE: Error interrupts enable

0: Error detection interrupts disabled

1: Error detection interrupts enabled

Note: Any of these errors generate an interrupt:

Arbitration Loss (ARLO)

Bus Error detection (BERR)

Overrun/Underrun (OVR)

Timeout detection (TIMEOUT)

PEC error detection (PECERR)

Alert pin event detection (ALERT)

Bit 6 TCIE: Transfer Complete interrupt enable

0: Transfer Complete interrupt disabled

1: Transfer Complete interrupt enabled

Note: Any of these events generates an interrupt:

Transfer Complete (TC)

Transfer Complete Reload (TCR)

Bit 5 STOPIE: STOP detection Interrupt enable

0: Stop detection (STOPF) interrupt disabled

1: Stop detection (STOPF) interrupt enabled

Bit 4 NACKIE: Not acknowledge received Interrupt enable

0: Not acknowledge (NACKF) received interrupts disabled

1: Not acknowledge (NACKF) received interrupts enabled

Bit 3 ADDRIE: Address match Interrupt enable (target only)

0: Address match (ADDR) interrupts disabled

1: Address match (ADDR) interrupts enabled

Bit 2 RXIE: RX Interrupt enable

0: Receive (RXNE) interrupt disabled

1: Receive (RXNE) interrupt enabled

Bit 1 TXIE: TX Interrupt enable

0: Transmit (TXIS) interrupt disabled

1: Transmit (TXIS) interrupt enabled

Bit 0 PE: Peripheral enable

0: Peripheral disable

1: Peripheral enable

Note: When PE=0, the I2C SCL and SDA lines are released. Internal state machines and status bits are put back to their reset value. When cleared, PE must be kept low for at least 3 APB clock cycles.

21.6.2 Control register 2 (I2C_CR2)

Address offset: 0x04

Reset value: 0x0000 0000

Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 × PCLK1+6 × I2CCLK.

31302928272625242322212019181716
Res.Res.Res.Res.Res.PEC
BYTE
AUTO
END
RE
LOAD
NBYTES[7:0]
rsrwrwrw
1514131211109876543210
NACKSTOPSTARTHEAD
10R
ADD10RD_W
RN
SADD[9:0]
rsrsrsrwrwrwrw

Bits 31:27 Reserved, must be kept at reset value.

Bit 26 PECBYTE: Packet error checking byte

This bit is set by software, and cleared by hardware when the PEC is transferred, or when a STOP condition or an Address matched is received, also when PE=0.

0: No PEC transfer.

1: PEC transmission/reception is requested

Note: Writing '0' to this bit has no effect.

This bit has no effect when RELOAD is set.

This bit has no effect in target mode when SBC=0.

If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 25 AUTOEND: Automatic end mode (controller mode)

This bit is set and cleared by software.

0: software end mode: TC flag is set when NBYTES data are transferred, stretching SCL low.

1: Automatic end mode: a STOP condition is automatically sent when NBYTES data are transferred.

Note: This bit has no effect in target mode or when the RELOAD bit is set.

Bit 24 RELOAD: NBYTES reload mode

This bit is set and cleared by software.

0: The transfer is completed after the NBYTES data transfer (STOP or RESTART follows).

1: The transfer is not completed after the NBYTES data transfer (NBYTES are reloaded).

TCR flag is set when NBYTES data are transferred, stretching SCL low.

Bits 23:16 NBYTES[7:0]: Number of bytes

The number of bytes to be transmitted/received is programmed there. This field is don't care in target mode with SBC=0.

Note: Changing these bits when the START bit is set is not allowed.

Bit 15 NACK: NACK generation (target mode)

The bit is set by software, cleared by hardware when the NACK is sent, or when a STOP condition or an Address matched is received, or when PE=0.

Note: Writing '0' to this bit has no effect.

This bit is used in target mode only: in controller receiver mode, NACK is automatically generated after last byte preceding STOP or RESTART condition, whatever the NACK bit value.

When an overrun occurs in target receiver NOSTRETCH mode, a NACK is automatically generated whatever the NACK bit value.

When hardware PEC checking is enabled (PECBYTE=1), the PEC acknowledge value does not depend on the NACK value.

Bit 14 STOP: Stop generation (controller mode)

The bit is set by software, cleared by hardware when a Stop condition is detected, or when PE = 0.

In Controller Mode:

Note: Writing '0' to this bit has no effect.

Bit 13 START: Start generation

This bit is set by software, and cleared by hardware after the Start followed by the address sequence is sent, by an arbitration loss, by a timeout error detection, or when PE = 0. It can also be cleared by software by writing '1' to the ADDRCF bit in the I2C_ICR register.

Note: Writing '0' to this bit has no effect.

The START bit can be set even if the bus is BUSY or I2C is in target mode.

This bit has no effect when RELOAD is set.

Bit 12 HEAD10R: 10-bit address header only read direction (controller receiver mode)

Note: Changing this bit when the START bit is set is not allowed.

Bit 11 ADD10: 10-bit addressing mode (controller mode)

Note: Changing this bit when the START bit is set is not allowed.

Bit 10 RD_WRN: Transfer direction (controller mode)

Note: Changing this bit when the START bit is set is not allowed.

21.6.3 Own address 1 register (I2C_OAR1)

Address offset: 0x08

Reset value: 0x0000 0000

Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to \(2 \times \text{PCLK1} + 6 \times \text{I2CCLK}\).

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
OA1ENRes.Res.Res.Res.OA1
MODE
OA1[9:8]OA1[7:1]OA1[0]
rwrwrwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bit 15 OA1EN: Own Address 1 enable

0: Own address 1 disabled. The received target address OA1 is NACKed.

1: Own address 1 enabled. The received target address OA1 is ACKed.

Bits 14:11 Reserved, must be kept at reset value.

Bit 10 OA1MODE Own Address 1 10-bit mode

0: Own address 1 is a 7-bit address.

1: Own address 1 is a 10-bit address.

Note: This bit can be written only when OA1EN=0.

Bits 9:8 OA1[9:8]: Interface address

7-bit addressing mode: don't care

10-bit addressing mode: bits 9:8 of address

Note: These bits can be written only when OA1EN=0.

Bits 7:1 OA1[7:1]: Interface address

Bits 7:1 of address

Note: These bits can be written only when OA1EN=0.

Bit 0 OA1[0]: Interface address

7-bit addressing mode: don't care

10-bit addressing mode: bit 0 of address

Note: This bit can be written only when OA1EN=0.

21.6.4 Own address 2 register (I2C_OAR2)

Address offset: 0x0C

Reset value: 0x0000 0000

Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 × PCLK1+6 × I2CCLK.

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
OA2ENRes.Res.Res.Res.OA2MSK[2:0]OA2[7:1]Res.
rwrwrw

Bits 31:16 Reserved, must be kept at reset value.

Bit 15 OA2EN: Own Address 2 enable

0: Own address 2 disabled. The received target address OA2 is NACKed.

1: Own address 2 enabled. The received target address OA2 is ACKed.

Bits 14:11 Reserved, must be kept at reset value.

Bits 10:8 OA2MSK[2:0]: Own Address 2 masks

000: No mask

001: OA2[1] is masked and don't care. Only OA2[7:2] are compared.

010: OA2[2:1] are masked and don't care. Only OA2[7:3] are compared.

011: OA2[3:1] are masked and don't care. Only OA2[7:4] are compared.

100: OA2[4:1] are masked and don't care. Only OA2[7:5] are compared.

101: OA2[5:1] are masked and don't care. Only OA2[7:6] are compared.

110: OA2[6:1] are masked and don't care. Only OA2[7] is compared.

111: OA2[7:1] are masked and don't care. No comparison is done, and all (except reserved) 7-bit received addresses are acknowledged.

Note: These bits can be written only when OA2EN=0.

As soon as OA2MSK is not equal to 0, the reserved I2C addresses (0b0000xxx and 0b1111xxx) are not acknowledged even if the comparison matches.

Bits 7:1 OA2[7:1]: Interface address

bits 7:1 of address

Note: These bits can be written only when OA2EN=0.

Bit 0 Reserved, must be kept at reset value.

21.6.5 Timing register (I2C_TIMINGR)

Address offset: 0x10

Reset value: 0x0000 0000

Access: No wait states

31302928272625242322212019181716
PRESC[3:0]Res.Res.Res.Res.SCLDEL[3:0]SDADEL[3:0]
rwrwrw
1514131211109876543210
SCLH[7:0]SCLL[7:0]
rwrw

Bits 31:28 PRESC[3:0]: Timing prescaler

This field is used to prescale I2CCLK in order to generate the clock period \(t_{\text{PRESC}}\) used for data setup and hold counters (refer to I2C timings on page 458) and for SCL high and low level counters (refer to I2C controller initialization on page 472).

\[t_{\text{PRESC}} = (\text{PRESC}+1) \times t_{\text{I2CCLK}}\]

Bits 27:24 Reserved, must be kept at reset value.

Bits 23:20 SCLDEL[3:0]: Data setup time

This field is used to generate a delay \(t_{\text{SCLDEL}}\) between SDA edge and SCL rising edge in transmission mode.

\[t_{\text{SCLDEL}} = (\text{SCLDEL}+1) \times t_{\text{PRESC}}\]

Note: \(t_{\text{SCLDEL}}\) is used to generate \(t_{\text{SU:DAT}}\) timing.

Bits 19:16 SDADEL[3:0]: Data hold time

This field is used to generate the delay \(t_{\text{SDADEL}}\) between SCL falling edge SDA edge in transmission mode.

\[t_{\text{SDADEL}} = \text{SDADEL} \times t_{\text{PRESC}}\]

Note: SDADEL is used to generate \(t_{\text{HD:DAT}}\) timing.

Bits 15:8 SCLH[7:0]: SCL high period (controller mode)

This field is used to generate the SCL high period in controller mode.

\[t_{\text{SCLH}} = (\text{SCLH}+1) \times t_{\text{PRESC}}\]

Note: SCLH is also used to generate \(t_{\text{SU:STO}}\) and \(t_{\text{HD:STA}}\) timing.

Bits 7:0 SCLL[7:0]: SCL low period (controller mode)

This field is used to generate the SCL low period in controller mode.

\[t_{\text{SCLL}} = (\text{SCLL}+1) \times t_{\text{PRESC}}\]

Note: SCLL is also used to generate \(t_{\text{BUF}}\) and \(t_{\text{SU:STA}}\) timings.

Note: This register must be configured when the I2C is disabled (PE = 0).

21.6.6 Timeout register (I2C_TIMEOUTR)

Address offset: 0x14

Reset value: 0x0000 0000

Access: No wait states, except if a write access occurs while a write access to this register is ongoing. In this case, wait states are inserted in the second write access until the previous one is completed. The latency of the second write access can be up to 2 × PCLK1+6 × I2CCLK.

31302928272625242322212019181716
TEXTENRes.Res.Res.TIMEOUTB [11:0]
rwrw
1514131211109876543210
TIMOUTENRes.Res.TIDLETIMEOUTA [11:0]
rwrwrw

Bit 31 TEXTEN: Extended clock timeout enable

0: Extended clock timeout detection is disabled

1: Extended clock timeout detection is enabled. When a cumulative SCL stretch for more than \(t_{LOW:EXT}\) is done by the I2C interface, a timeout error is detected (TIMEOUT=1).

Bits 30:28 Reserved, must be kept at reset value.

Bits 27:16 TIMEOUTB[11:0]: Bus timeout B

This field is used to configure the cumulative clock extension timeout:

In controller mode, the controller cumulative clock low extend time (\(t_{LOW:MEXT}\)) is detected

In target mode, the target cumulative clock low extend time (\(t_{LOW:SEXT}\)) is detected

\(t_{LOW:EXT} = (TIMEOUTB+1) \times 2048 \times t_{I2CCLK}\)

Note: These bits can be written only when TEXTEN=0.

Bit 15 TIMOUTEN: Clock timeout enable

0: SCL timeout detection is disabled

1: SCL timeout detection is enabled: when SCL is low for more than \(t_{TIMEOUT}\) (TIDLE=0) or high for more than \(t_{IDLE}\) (TIDLE=1), a timeout error is detected (TIMEOUT=1).

Bits 14:13 Reserved, must be kept at reset value.

Bit 12 TIDLE: Idle clock timeout detection

0: TIMEOUTA is used to detect SCL low timeout

1: TIMEOUTA is used to detect both SCL and SDA high timeout (bus idle condition)

Note: This bit can be written only when TIMOUTEN=0.

Bits 11:0 TIMEOUTA[11:0]: Bus Timeout A

This field is used to configure:

– The SCL low timeout condition \(t_{TIMEOUT}\) when TIDLE=0

\(t_{TIMEOUT} = (TIMEOUTA+1) \times 2048 \times t_{I2CCLK}\)

– The bus idle condition (both SCL and SDA high) when TIDLE=1

\(t_{IDLE} = (TIMEOUTA+1) \times 4 \times t_{I2CCLK}\)

Note: These bits can be written only when TIMOUTEN=0.

Note: If the SMBus feature is not supported, this register is reserved and forced by hardware to “0x00000000”. Refer to Section 21.3: I2C implementation.

21.6.7 Interrupt and status register (I2C_ISR)

Address offset: 0x18

Reset value: 0x0000 0001

Access: No wait states

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.ADDCODE[6:0]DIR
rr
1514131211109876543210
BUSYRes.ALERTTIME OUTPEC ERROVRARLOBERRTCRTCSTOPFNACKFADDRRXNETXISTXE
rrrrrrrrrrrrrrsrs

Bits 31:24 Reserved, must be kept at reset value.

Bits 23:17 ADDCODE[6:0]: Address match code (Target mode)

These bits are updated with the received address when an address match event occurs (ADDR = 1).

In the case of a 10-bit address, ADDCODE provides the 10-bit header followed by the 2 MSBs of the address.

Bit 16 DIR: Transfer direction (Target mode)

This flag is updated when an address match event occurs (ADDR=1).

0: Write transfer, target enters receiver mode.

1: Read transfer, target enters transmitter mode.

Bit 15 BUSY: Bus busy

This flag indicates that a communication is in progress on the bus. It is set by hardware when a START condition is detected. It is cleared by hardware when a Stop condition is detected, or when PE=0.

Bit 14 Reserved, must be kept at reset value.

Bit 13 ALERT: SMBus alert

This flag is set by hardware when SMBHEN=1 (SMBus host configuration), ALERTEN=1 and a SMBALERT event (falling edge) is detected on SMBA pin. It is cleared by software by setting the ALERTCF bit.

Note: This bit is cleared by hardware when PE=0.

If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'.

Refer to Section 21.3: I2C implementation.

Bit 12 TIMEOUT: Timeout or tLOW detection flag

This flag is set by hardware when a timeout or extended clock timeout occurred. It is cleared by software by setting the TIMEOUTCF bit.

Note: This bit is cleared by hardware when PE=0.

If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'.

Refer to Section 21.3: I2C implementation.

21.6.8 Interrupt clear register (I2C_ICR)

Address offset: 0x1C

Reset value: 0x0000 0000

Access: No wait states

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.ALERT
CF
TIM
OUTCF
PECCFOVRCFARLO
CF
BERR
CF
Res.Res.STOP
CF
NACK
CF
ADDR
CF
Res.Res.Res.
wwwwwwwww

Bits 31:14 Reserved, must be kept at reset value.

Bit 13 ALERTCF: Alert flag clear

Writing 1 to this bit clears the ALERT flag in the I2C_ISR register.

Note: If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 12 TIMOUTCF: Timeout detection flag clear

Writing 1 to this bit clears the TIMEOUT flag in the I2C_ISR register.

Note: If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 11 PECCF: PEC Error flag clear

Writing 1 to this bit clears the PECERR flag in the I2C_ISR register.

Note: If the SMBus feature is not supported, this bit is reserved and forced by hardware to '0'. Refer to Section 21.3: I2C implementation.

Bit 10 OVRCF: Overrun/Underrun flag clear

Writing 1 to this bit clears the OVR flag in the I2C_ISR register.

Bit 9 ARLOCF: Arbitration Lost flag clear

Writing 1 to this bit clears the ARLO flag in the I2C_ISR register.

Bit 8 BERRCF: Bus error flag clear

Writing 1 to this bit clears the BERRF flag in the I2C_ISR register.

Bits 7:6 Reserved, must be kept at reset value.

Bit 5 STOPCF: Stop detection flag clear

Writing 1 to this bit clears the STOPF flag in the I2C_ISR register.

Bit 4 NACKCF: Not Acknowledge flag clear

Writing 1 to this bit clears the ACKF flag in I2C_ISR register.

Bit 3 ADDRCF: Address matched flag clear

Writing 1 to this bit clears the ADDR flag in the I2C_ISR register. Writing 1 to this bit also clears the START bit in the I2C_CR2 register.

Bits 2:0 Reserved, must be kept at reset value.

21.6.9 PEC register (I2C_PECR)

Address offset: 0x20

Reset value: 0x0000 0000

Access: No wait states

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.PEC[7:0]
r

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:0 PEC[7:0] Packet error checking register

This field contains the internal PEC when PECEN=1.

The PEC is cleared by hardware when PE=0.

Note: If the SMBus feature is not supported, this register is reserved and forced by hardware to “0x00000000”. Refer to Section 21.3: I2C implementation.

21.6.10 Receive data register (I2C_RXDR)

Address offset: 0x24

Reset value: 0x0000 0000

Access: No wait states

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.RXDATA[7:0]
r

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:0 RXDATA[7:0] 8-bit receive data

Data byte received from the I2C bus.

21.6.11 Transmit data register (I2C_TXDR)

Address offset: 0x28

Reset value: 0x0000 0000

Access: No wait states

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.TXDATA[7:0]
rw

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:0 TXDATA[7:0] 8-bit transmit data

Data byte to be transmitted to the I2C bus.

Note: These bits can be written only when TXE=1.

21.6.12 I2C register map

The table below provides the I2C register map and reset values.

Table 100. I2C register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x0I2C_CR1Res.Res.Res.Res.Res.Res.Res.Res.PECENALERTENSMBDENSMBHENGCENRes.NOSTRETCHSBCRXDMAENTXDMAENRes.ANFOFFDNF[3:0]ERRIETCIESTOPIENACKIEADDRIERXIETXIEPE
Reset value000000000000000000000
0x4I2C_CR2Res.Res.Res.Res.Res.PECBYTEAUTOENDRELOADNBYTES[7:0]NACKSTOPSTARTHEAD10RADD10RD_WRNSADD[9:0]
Reset value00000000000000000000000000
0x8I2C_OAR1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.OA1ENRes.Res.Res.Res.OA1MODEOA1[9:0]
Reset value00000000000
0xCI2C_OAR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.OA2ENRes.Res.Res.Res.OA2MSK[2:0]OA2[7:1]Res.
Reset value0000000000
0x10I2C_TIMINGRPRESC[3:0]Res.Res.Res.SCLDEL[3:0]SDADEL[3:0]SCLH[7:0]SCLL[7:0]
Reset value000000000000000000000000000
0x14I2C_TIMEOUTRTEXTENRes.Res.Res.TIMEOUTB[11:0]TIMOUTENRes.Res.TIDLETIMEOUTA[11:0]
Reset value000000000000000000000000000
0x18I2C_ISRRes.Res.Res.Res.Res.Res.Res.Res.ADDCODE[6:0]DIRBUSYRes.ALERTTIMEOUTPECERROVRARLOBERRTCRTCSTOPFNACKFADDRFRXNETXISTXE
Reset value0000000000000000000001
0x1CI2C_ICRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ALERTCFTIMOUTCFPECCFOVRCFARLOCFBERRCFRes.Res.STOPCFNACKCFADDRCFRes.Res.Res.
Reset value000000000
0x20I2C_PECRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.PEC[7:0]
Reset value000000000
0x24I2C_RXDRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.RXDATA[7:0]
Reset value000000000

Table 100. I2C register map and reset values (continued)

OffsetRegister313029282726252423222120191817161514131211109876543210
0x28I2C_TXDRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TXDATA[7:0]
Reset value00000000