21. General-purpose timers (TIM16)

  1. Note:
  2. 1 In this section, “TIMx” should be understood as “TIM16” since there is only one instance of this timer in STM32WL30xx/31xx/33xx devices.
  3. 2 The DAC is available only on STM32WL33xx devices. Any reference to the DAC IP in this chapter is valid only for STM32WL33xx devices.

21.1 TIM16 introduction

The TIM16 timer consists of a 16-bit auto-reload counter driven by a programmable prescaler.

It may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM, complementary PWM with dead-time insertion), but it is also specifically used to drive the digital-to-analog converter (DAC). In fact, the timer is internally connected to the DAC and is able to drive it through its trigger output.

Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler and the RCC clock controller prescalers.

21.2 TIM16 main features

The TIM16 timer includes the following features:

Figure 129. TIM16 block diagram

Block diagram of the TIM16 timer peripheral showing internal components like the trigger controller, slave controller mode, prescalers, counters, and capture/compare registers, along with external inputs and outputs.

The diagram illustrates the internal architecture of the TIM16 timer. Key components and signal paths include:

Block diagram of the TIM16 timer peripheral showing internal components like the trigger controller, slave controller mode, prescalers, counters, and capture/compare registers, along with external inputs and outputs.

MSv58434V1

21.3 TIM16 functional description

21.3.1 Time-base unit

The main block of the programmable advanced-control timer is a 16-bit upcounter with its related auto-reload register. The counter clock can be divided by a prescaler.

The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The auto-reload register is preloaded. Writing to or reading from the auto-reload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the auto-reload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detailed for each configuration.

The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).

Note that the counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 130 and Figure 131 give some examples of the counter behavior when the prescaler ratio is changed on the fly:

Figure 130. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

The diagram illustrates the timing for changing the prescaler division from 1 to 2. The CK_PSC signal is a continuous clock. The CEN signal transitions from low to high, enabling the timer. The Timer clock = CK_CNT is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. An Update event (UEV) occurs at the transition from FC to 00. The Prescaler control register changes from 0 to 1. The Prescaler buffer changes from 0 to 1. The Prescaler counter shows values 0, 0, 1, 0, 1, 0, 1, 0, 1.

MS31076V2

Timing diagram for prescaler division change from 1 to 2. It shows the relationship between CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

Figure 131. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

The diagram illustrates the timing for changing the prescaler division from 1 to 4. The CK_PSC signal is a continuous clock. The CEN signal transitions from low to high, enabling the timer. The Timer clock = CK_CNT is derived from CK_PSC. The Counter register shows values F7, F8, F9, FA, FB, FC, 00, 01. An Update event (UEV) occurs at the transition from FC to 00. The Prescaler control register changes from 0 to 3. The Prescaler buffer changes from 0 to 3. The Prescaler counter shows values 0, 0, 1, 2, 3, 0, 1, 2, 3.

MS31077V2

Timing diagram for prescaler division change from 1 to 4. It shows the relationship between CK_PSC, CEN, Timer clock = CK_CNT, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter over time.

21.3.2 Counter modes

Upcounting mode

In upcounting mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

If the repetition counter is used, the update event (UEV) is generated after upcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR). Else the update event is generated at each counter overflow.

Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.

When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.

Figure 132. Counter timing diagram, internal clock divided by 1

Timing diagram for a counter showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

The diagram illustrates the timing of various signals relative to the counter register values. The counter register is shown as a sequence of values from 31 to 07. The Counter overflow signal is a pulse that occurs when the counter reaches 36 (0x24). The Update event (UEV) is a pulse that occurs when the counter reaches 36. The Update interrupt flag (UIF) is a pulse that occurs when the counter reaches 36. The Counter overflow signal is a pulse that occurs when the counter reaches 36. The Update event (UEV) is a pulse that occurs when the counter reaches 36. The Update interrupt flag (UIF) is a pulse that occurs when the counter reaches 36.

MS31078V2

Timing diagram for a counter showing CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 133. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a continuous square wave. The CNT_EN signal is a high-level pulse that enables the counter. The Timer clock (CK_CNT) is derived from CK_PSC and has a frequency half that of CK_PSC. The Counter register shows the sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, 0003. A Counter overflow occurs when the counter reaches 0036 and rolls over to 0000. This overflow triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF).

MS31079V2

Timing diagram for counter with internal clock divided by 2. Shows CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 134. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram shows the counter operation with the internal clock divided by 4. CK_PSC is a continuous square wave. CNT_EN is a high-level pulse. The Timer clock (CK_CNT) has a frequency one-quarter that of CK_PSC. The Counter register values shown are 0035, 0036, 0000, 0001. A Counter overflow occurs at 0036, triggering an Update event (UEV) and setting the Update interrupt flag (UIF).

MS31080V2

Timing diagram for counter with internal clock divided by 4. Shows CK_PSC, CNT_EN, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 135. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram depicts the counter operation with an arbitrary division factor N. CK_PSC is a continuous square wave. The Timer clock (CK_CNT) is a divided version of CK_PSC. The Counter register shows values 1F, 20, and 00. An overflow occurs when the counter transitions from 1F to 20 and then rolls over to 00. This overflow event triggers an Update event (UEV) and sets the Update interrupt flag (UIF).

MS31081V2

Timing diagram for counter with internal clock divided by N. Shows CK_PSC, Timer clock = CK_CNT, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 136. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Timing diagram for ARPE=0 showing CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

This timing diagram illustrates the behavior of a timer when ARPE=0. The signals shown are:

MS31082V2

Timing diagram for ARPE=0 showing CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Figure 137. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

Timing diagram for ARPE=1 showing CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register.

This timing diagram illustrates the behavior of a timer when ARPE=1. The signals shown are:

MS31083V2

Timing diagram for ARPE=1 showing CK_PSC, CEN, Timer clock, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), Auto-reload preload register, and Auto-reload shadow register.

21.3.3 Repetition counter

Section 21.3.1: Time-base unit describes how the update event (UEV) is generated with respect to the counter overflows. It is actually generated only when the repetition counter has reached zero. This can be useful when generating PWM signals.

This means that data are transferred from the preload registers to the shadow registers (TIMx_ARR auto-reload register, TIMx_PSC prescaler register, but also TIMx_CCRx capture/compare registers in compare mode) every N counter overflows, where N is the value in the TIMx_RCR repetition counter register.

The repetition counter is decremented at each counter overflow.

The repetition counter is an auto-reload type; the repetition rate is maintained as defined by the TIMx_RCR register value (refer to Figure 138). When the update event is generated by software (by setting the UG bit in TIMx_EGR register) or by hardware through the slave mode controller, it occurs immediately whatever the value of the repetition counter is and the repetition counter is reloaded with the content of the TIMx_RCR register.

Figure 138. Update rate examples depending on mode and TIMx_RCR register settings

Timing diagram showing Edge-aligned mode Upcounting for various TIMx_RCR values (0, 1, 2, 3) and a re-synchronization case. It illustrates the relationship between the counter (TIMx_CNT) and the Update Event (UEV) markers.

The diagram illustrates the generation of Update Events (UEV) in Edge-aligned mode with Upcounting. It shows the counter (TIMx_CNT) waveform and the corresponding UEV markers (arrows) for different TIMx_RCR settings:

UEV Update Event: Preload registers transferred to active registers and update interrupt generated.

MS31084V2

Timing diagram showing Edge-aligned mode Upcounting for various TIMx_RCR values (0, 1, 2, 3) and a re-synchronization case. It illustrates the relationship between the counter (TIMx_CNT) and the Update Event (UEV) markers.

21.3.4 Clock selection

The counter clock can be provided by the following clock sources:

Internal clock source (CK_INT)

The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are control bits and can be changed only by software (except UG which remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.

Figure 139 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 139. Control circuit in normal mode, internal clock divided by 1

Timing diagram for Figure 139 showing the relationship between Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock, and Counter register.

The diagram shows the following signals over time:

MS31085V2

Timing diagram for Figure 139 showing the relationship between Internal clock, CEN=CNT_EN, UG, CNT_INIT, Counter clock, and Counter register.

External clock source mode 1

This mode is selected when SMS=111 in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.

Figure 140. TI1 external clock connection example

Block diagram for Figure 140 showing the TI1 external clock connection example.

The diagram illustrates the connection of an external clock source (TI1) to the TIMx timer. The components and connections are as follows:

Block diagram for Figure 140 showing the TI1 external clock connection example.

For example, to configure the upcounter to count in response to a rising edge on the TI1 input, use the following procedure:

  1. 1. Select the proper TI1x source (internal or external) with the TI1SEL[3:0] bits in the TIMx_TISEL register.
  2. 2. Configure channel 1 to detect rising edges on the TI1 input by writing CC2S = '01' in the TIMx_CCMR1 register.
  3. 3. Configure the input filter duration by writing the IC1F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC1F=0000).
  4. 4. Select rising edge polarity by writing CC1P=0 and CC1NP=0 in the TIMx_CCER register.
  5. 5. Configure the timer in external clock mode 1 by writing SMS=111 in the TIMx_SMCR register.
  6. 6. Select TI1 as the trigger input source by writing TS=110 in the TIMx_SMCR register.
  7. 7. Enable the counter by writing CEN=1 in the TIMx_CR1 register.

Note: The capture prescaler is not used for triggering, so you don't need to configure it.

When a rising edge occurs on TI1, the counter counts once and the TIF flag is set.

The delay between the rising edge on TI1 and the actual clock of the counter is due to the resynchronization circuit on TI1 input.

Figure 141. Control circuit in external clock mode 1

Timing diagram for Figure 141 showing the control circuit in external clock mode 1. The diagram includes five signals: TI1 (input signal with rising edges), CNT_EN (counter enable signal), Counter clock = CK_CNT = CK_PSC (clock signal derived from TI1 rising edges), Counter register (showing values 34, 35, and 36 at three consecutive clock cycles), and TIF (Timer Input Flag). The TIF signal is high when a rising edge on TI1 occurs and is cleared by writing TIF=0. The counter register increments by 1 on each rising edge of the counter clock.
Timing diagram for Figure 141 showing the control circuit in external clock mode 1. The diagram includes five signals: TI1 (input signal with rising edges), CNT_EN (counter enable signal), Counter clock = CK_CNT = CK_PSC (clock signal derived from TI1 rising edges), Counter register (showing values 34, 35, and 36 at three consecutive clock cycles), and TIF (Timer Input Flag). The TIF signal is high when a rising edge on TI1 occurs and is cleared by writing TIF=0. The counter register increments by 1 on each rising edge of the counter clock.

21.3.5 Capture/compare channels

Each Capture/Compare channel is built around a capture/compare register (including a shadow register), a input stage for capture (with digital filter, multiplexing and prescaler) and an output stage (with comparator and output control).

Figure 142 to Figure 144 give an overview of one Capture/Compare channel.

The input stage samples the corresponding TIx input to generate a filtered signal TIxF. Then, an edge detector with polarity selection generates a signal (TIxFPx) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).

Figure 142. Capture/compare channel (example: channel 1 input stage)

Block diagram of the capture/compare channel 1 input stage. Shows input TI1 passing through a filter downcounter (configured by ICF[3:0] in TIMx_CCMR1 and clock f_DTS) to produce TI1F, feeding an Edge Detector which generates TI1F_Rising and TI1F_Falling. A multiplexer selected by CC1P/CC1NP in TIMx_CCER selects polarity. An XOR/OR stage generates TI1F_ED to the slave mode controller. Multiplexer inputs 01, 10, 11 (selected by CC1S[1:0] in TIMx_CCMR1) take TI1FP1, TI2FP1, or TRC from slave mode controller to output IC1. A divider (/1, /2, /4, /8 configured by ICPS[1:0]) outputs IC1PS, controlled by enable CC1E in TIMx_CCER.
Block diagram of the capture/compare channel 1 input stage. Shows input TI1 passing through a filter downcounter (configured by ICF[3:0] in TIMx_CCMR1 and clock f_DTS) to produce TI1F, feeding an Edge Detector which generates TI1F_Rising and TI1F_Falling. A multiplexer selected by CC1P/CC1NP in TIMx_CCER selects polarity. An XOR/OR stage generates TI1F_ED to the slave mode controller. Multiplexer inputs 01, 10, 11 (selected by CC1S[1:0] in TIMx_CCMR1) take TI1FP1, TI2FP1, or TRC from slave mode controller to output IC1. A divider (/1, /2, /4, /8 configured by ICPS[1:0]) outputs IC1PS, controlled by enable CC1E in TIMx_CCER.

The output stage generates an intermediate waveform which is then used for reference: OCxRef (active high). The polarity acts at the end of the chain.

Figure 143. Capture/compare channel 1 main circuit

Block diagram of the capture/compare channel 1 main circuit. Connects to APB Bus via MCU-peripheral interface (high byte 8-bit, low byte 8-bit for 16-bit). Features Capture/compare preload register and Capture/compare shadow register. Signals include read_in_progress from read CCR1H/CCR1L flip-flop (S/R), write_in_progress from write CCR1H/CCR1L flip-flop (S/R). Controlled by CC1S[1:0] for input/output mode, OC1PE in TIMx_CCMR1, UEV (from time base unit), capture_transfer, compare_transfer, Counter, and comparator (generating CNT>CCR1 and CNT=CCR1). Input capture triggered by IC1PS, CC1E, and software trigger CC1G in TIMx_EGR.
Block diagram of the capture/compare channel 1 main circuit. Connects to APB Bus via MCU-peripheral interface (high byte 8-bit, low byte 8-bit for 16-bit). Features Capture/compare preload register and Capture/compare shadow register. Signals include read_in_progress from read CCR1H/CCR1L flip-flop (S/R), write_in_progress from write CCR1H/CCR1L flip-flop (S/R). Controlled by CC1S[1:0] for input/output mode, OC1PE in TIMx_CCMR1, UEV (from time base unit), capture_transfer, compare_transfer, Counter, and comparator (generating CNT>CCR1 and CNT=CCR1). Input capture triggered by IC1PS, CC1E, and software trigger CC1G in TIMx_EGR.

Figure 144. Output stage of capture/compare channel (channel 1)

Block diagram of the output stage of capture/compare channel (channel 1). The diagram shows the signal flow from the Output mode controller (receiving CNT>CCR1 and CNT=CCR1) to an Output selector (receiving OC1REF and OCxREF(1)). The Output selector output goes to a Dead-time generator (receiving DTG[7:0]) and to multiplexers. The multiplexers select between OC1REFC, OC1_DT, and OC1N_DT based on bits in TIMx_CCER (CC1P, CC1NE, CC1E, CC1NP). The multiplexers also receive '0' and '1' inputs. The outputs of the multiplexers pass through inverters and then to Output enable circuits, which produce the final OC1 and OC1N signals. The TIMx_BDTR register provides CC1NE, CC1E, MOE, OSSI, and OSSR bits to the enable circuits.
Block diagram of the output stage of capture/compare channel (channel 1). The diagram shows the signal flow from the Output mode controller (receiving CNT>CCR1 and CNT=CCR1) to an Output selector (receiving OC1REF and OCxREF(1)). The Output selector output goes to a Dead-time generator (receiving DTG[7:0]) and to multiplexers. The multiplexers select between OC1REFC, OC1_DT, and OC1N_DT based on bits in TIMx_CCER (CC1P, CC1NE, CC1E, CC1NP). The multiplexers also receive '0' and '1' inputs. The outputs of the multiplexers pass through inverters and then to Output enable circuits, which produce the final OC1 and OC1N signals. The TIMx_BDTR register provides CC1NE, CC1E, MOE, OSSI, and OSSR bits to the enable circuits.

1. OCxREF, where x is the rank of the complementary channel

The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.

In capture mode, captures are actually done in the shadow register, which is copied into the preload register.

In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.

21.3.6 Input capture mode

In Input capture mode, the Capture/Compare Registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCxIF flag was already high, then the over-capture flag CCxOF (TIMx_SR register) is set. CCxIF can be cleared by software by writing it to '0' or by reading the captured data stored in the TIMx_CCRx register. CCxOF is cleared when you write it to '0'.

The following example shows how to capture the counter value in TIMx_CCR1 when TI1 input rises. To do this, use the following procedure:

  1. 1. Select the active input: TIMx_CCR1 must be linked to the TI1 input, so write the CC1S bits to 01 in the TIMx_CCMR1 register. As soon as CC1S becomes different from 00, the channel is configured in input and the TIMx_CCR1 register becomes read-only.
  2. 2. Program the input filter duration you need with respect to the signal you connect to the timer (when the input is one of the TIx (ICxF bits in the TIMx_CCMRx register). Let's imagine that, when toggling, the input signal is not stable during at most 5 internal clock cycles. We must program a filter duration longer than these 5 clock cycles. We can validate a transition on TI1 when 8 consecutive samples with the new level have been

detected (sampled at \(f_{DTS}\) frequency). Then write IC1F bits to 0011 in the TIMx_CCMR1 register.

  1. 3. Select the edge of the active transition on the TI1 channel by writing CC1P bit to 0 in the TIMx_CCER register (rising edge in this case).
  2. 4. Program the input prescaler. In our example, we wish the capture to be performed at each valid transition, so the prescaler is disabled (write IC1PS bits to '00' in the TIMx_CCMR1 register).
  3. 5. Enable capture from the counter into the capture register by setting the CC1E bit in the TIMx_CCER register.
  4. 6. If needed, enable the related interrupt request by setting the CC1IE bit in the TIMx_DIER register, and/or the DMA request by setting the CC1DE bit in the TIMx_DIER register.

When an input capture occurs:

In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which could happen after reading the flag and before reading the data.

Note: IC interrupt and/or DMA requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.

21.3.7 Forced output mode

In output mode (CCxS bits = 00 in the TIMx_CCMRx register), each output compare signal (OCxREF and then OCx/OCxN) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.

To force an output compare signal (OCXREF/OCx) to its active level, you just need to write 101 in the OCxM bits in the corresponding TIMx_CCMRx register. Thus OCXREF is forced high (OCxREF is always active high) and OCx get opposite value to CCxP polarity bit.

For example: CCxP=0 (OCx active high) => OCx is forced to high level.

The OCxREF signal can be forced low by writing the OCxM bits to 100 in the TIMx_CCMRx register.

Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt and DMA requests can be sent accordingly. This is described in the output compare mode section below.

21.3.8 Output compare mode

This function is used to control an output waveform or indicating when a period of time has elapsed.

When a match is found between the capture/compare register and the counter, the output compare function:

The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.

In output compare mode, the update event UEV has no effect on OCxREF and OCx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One-pulse mode).

Procedure:

  1. 1. Select the counter clock (internal, external, prescaler).
  2. 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
  3. 3. Set the CCxIE bit if an interrupt request is to be generated.
  4. 4. Select the output mode. For example:
    • – Write OCxM = 011 to toggle OCx output pin when CNT matches CCRx
    • – Write OCxPE = 0 to disable preload register
    • – Write CCxP = 0 to select active high polarity
    • – Write CCxE = 1 to enable the output
  5. 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.

The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE='0', else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 145.

Figure 145. Output compare mode, toggle on OC1

Timing diagram for Output compare mode, toggle on OC1. It shows three signals: TIM1_CNT, TIM1_CCR1, and oc1ref=OC1. TIM1_CNT is a counter that increments from 0039 to 003A, then 003B, and eventually reaches B200 and B201. TIM1_CCR1 is a compare register that holds 003A and then B201. The oc1ref=OC1 signal is a square wave that toggles at each match between TIM1_CNT and TIM1_CCR1. A match is detected when TIM1_CNT reaches 003A and then B201. An arrow points to the match at 003A with the text 'Write B201h in the CC1R register'. Another arrow points to the match at B201 with the text 'Match detected on CCR1 Interrupt generated if enabled'. The diagram is labeled MS31092V1.

Write B201h in the CC1R register

TIM1_CNT: 0039, 003A, 003B, ..., B200, B201

TIM1_CCR1: 003A, ..., B201

oc1ref=OC1: [Square wave toggling at matches]

Match detected on CCR1
Interrupt generated if enabled

MS31092V1

Timing diagram for Output compare mode, toggle on OC1. It shows three signals: TIM1_CNT, TIM1_CCR1, and oc1ref=OC1. TIM1_CNT is a counter that increments from 0039 to 003A, then 003B, and eventually reaches B200 and B201. TIM1_CCR1 is a compare register that holds 003A and then B201. The oc1ref=OC1 signal is a square wave that toggles at each match between TIM1_CNT and TIM1_CCR1. A match is detected when TIM1_CNT reaches 003A and then B201. An arrow points to the match at 003A with the text 'Write B201h in the CC1R register'. Another arrow points to the match at B201 with the text 'Match detected on CCR1 Interrupt generated if enabled'. The diagram is labeled MS31092V1.

21.3.9 PWM mode

Pulse Width Modulation mode allows you to generate a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.

The PWM mode can be selected independently on each channel (one PWM per OCx output) by writing '110' (PWM mode 1) or '111' (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. You must enable the corresponding preload register by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the auto-reload preload register (in upcounting or center-aligned modes) by setting the ARPE bit in the TIMx_CR1 register.

As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, you have to initialize all the registers by setting the UG bit in the TIMx_EGR register.

OCx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. OCx output is enabled by a combination of the CCxE, CCxNE, MOE, OSSI and OSSR bits (TIMx_CCER and TIMx_BDTR registers). Refer to the TIMx_CCER register description for more details.

In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CCRx ≤ TIMx_CNT or TIMx_CNT ≤ TIMx_CCRx (depending on the direction of the counter).

The TIM16 is capable of upcounting only. Refer to Upcounting mode.

In the following example, we consider PWM mode 1. The reference PWM signal OCxREF is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the compare value in TIMx_CCRx is greater than the auto-reload value (in TIMx_ARR) then OCxREF is held at '1'. If the compare value is 0 then OCxRef is held at '0'. Figure 146 shows some edge-aligned PWM waveforms in an example where TIMx_ARR=8.

Figure 146. Edge-aligned PWM waveforms (ARR=8)

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register (0-11), OCXREF, and CCxIF signals for CCRx=4, CCRx=8, CCRx>8, and CCRx=0. OCXREF is a periodic square wave. CCxIF is a pulse at the start of each period. For CCRx=4, the output is high from counter 0 to 4. For CCRx=8, the output is high from counter 0 to 8. For CCRx>8, the output is high from counter 0 to 8. For CCRx=0, the output is high from counter 0 to 0. The diagram is labeled MS31093V1.

The figure shows edge-aligned PWM waveforms for a timer with an auto-reload register (ARR) value of 8. The counter register counts from 0 to 11. The OCXREF signal is a periodic square wave with a period of 12 counter ticks. The CCxIF signal is a pulse at the start of each period. The output signals for different CCRx values are shown:

MS31093V1

Timing diagram for edge-aligned PWM waveforms with ARR=8. The diagram shows the Counter register (0-11), OCXREF, and CCxIF signals for CCRx=4, CCRx=8, CCRx>8, and CCRx=0. OCXREF is a periodic square wave. CCxIF is a pulse at the start of each period. For CCRx=4, the output is high from counter 0 to 4. For CCRx=8, the output is high from counter 0 to 8. For CCRx>8, the output is high from counter 0 to 8. For CCRx=0, the output is high from counter 0 to 0. The diagram is labeled MS31093V1.

21.3.10 Complementary outputs and dead-time insertion

The TIM16 general-purpose timer can output one complementary signal and manage the switching-off and switching-on of the outputs.

This time is generally known as dead-time and you have to adjust it depending on the devices you have connected to the outputs and their characteristics (intrinsic delays of level-shifters, delays due to power switches...)

You can select the polarity of the outputs (main output OCx or complementary OCxN) independently for each output. This is done by writing to the CCxP and CCxNP bits in the TIMx_CCER register.

The complementary signals OCx and OCxN are activated by a combination of several control bits: the CCxE and CCxNE bits in the TIMx_CCER register and the MOE, OISx, OISxN, OSSR and OSSR bits in the TIMx_BDTR and TIMx_CR2 registers. Refer to Table 65 for more details. In particular, the dead-time is activated when switching to the idle state (MOE falling down to 0).

Dead-time insertion is enabled by setting both CCxE and CCxNE bits, and the MOE bit if the break circuit is present. There is one 10-bit dead-time generator for each channel. From a reference waveform OCxREF, it generates 2 outputs OCx and OCxN. If OCx and OCxN are active high:

If the delay is greater than the width of the active output (OCx or OCxN) then the corresponding pulse is not generated.

The following figures show the relationships between the output signals of the dead-time generator and the reference signal OCxREF. (we suppose CCxP=0, CCxNP=0, MOE=1, CCxE=1 and CCxNE=1 in these examples)

Figure 147. Complementary output with dead-time insertion.

Timing diagram for Figure 147 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

MS31095V1

Timing diagram for Figure 147 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

Figure 148. Dead-time waveforms with delay greater than the negative pulse.

Timing diagram for Figure 148 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

MS31096V1

Timing diagram for Figure 148 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

Figure 149. Dead-time waveforms with delay greater than the positive pulse.

Timing diagram for Figure 149 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

MS31097V1

Timing diagram for Figure 149 showing OCxREF, OCx, and OCxN waveforms. OCxREF is a square wave. OCx follows OCxREF with a delay on the falling edge and a delay on the rising edge. OCxN is the complement of OCx with a delay on the rising edge and a delay on the falling edge. The delays are indicated by double-headed arrows.

The dead-time delay is the same for each of the channels and is programmable with the DTG bits in the TIMx_BDTR register. Refer to Section 21.4.14: TIM16 break and dead-time register (TIMx_BDTR) for delay calculation.

Re-directing OCxREF to OCx or OCxN

In output mode (forced, output compare or PWM), OCxREF can be re-directed to the OCx output or to OCxN output by configuring the CCxE and CCxNE bits in the TIMx_CCER register.

This allows you to send a specific waveform (such as PWM or static active level) on one output while the complementary remains at its inactive level. Other alternative possibilities are to have both outputs at inactive level or both outputs active and complementary with dead-time.

Note: When only OCxN is enabled (CCxE=0, CCxNE=1), it is not complemented and becomes active as soon as OCxREF is high. For example, if CCxNP=0 then OCxN=OCxRef. On the other hand, when both OCx and OCxN are enabled (CCxE=CCxNE=1) OCx becomes active when OCxREF is high whereas OCxN is complemented and becomes active when OCxREF is low.

21.3.11 Using the break function

The purpose of the break function is to protect power switches driven by PWM signals generated with the TIM16 timer. The two break inputs are usually connected to fault outputs of power stages and 3-phase inverters. When activated, the break circuitry shuts down the PWM outputs and forces them to a predefined safe state.

When using the break function, the output enable signals and inactive levels are modified according to additional control bits (MOE, OSSI and OSSR bits in the TIMx_BDTR register, OISx and OISxN bits in the TIMx_CR2 register). In any case, the OCx and OCxN outputs cannot be set both to active level at a given time. Refer to Table 65 for more details.

When exiting from reset, the break circuit is disabled and the MOE bit is low. You can enable the break function by setting the BKE bit in the TIMx_BDTR register. The break input polarity can be selected by configuring the BKP bit in the same register. BKE and BKP can be modified at the same time. When the BKE and BKP bits are written, a delay of 1 APB clock cycle is applied before the writing is effective. Consequently, it is necessary to wait 1 APB clock period to correctly read back the bit after the write operation.

Because MOE falling edge can be asynchronous, a resynchronization circuit has been inserted between the actual signal (acting on the outputs) and the synchronous control bit (accessed in the TIMx_BDTR register). It results in some delays between the asynchronous and the synchronous signals. In particular, if you write MOE to 1 whereas it was low, you must insert a delay (dummy instruction) before reading it correctly. This is because you write the asynchronous signal and read the synchronous signal.

The break is generated by the BRK inputs which has:

Caution: An asynchronous (clockless) operation is only guaranteed when the programmable filter is disabled.

When a break occurs (selected level on the break input):

active level together. Note that because of the resynchronization on MOE, the dead-time duration is a bit longer than usual (around 2 ck_tim clock cycles).

Note: The break inputs is acting on level. Thus, the MOE cannot be set while the break input is active (neither automatically nor by software). In the meantime, the status flag BIF cannot be cleared.

The break can be generated by the BRK input which has a programmable polarity and an enable bit BKE in the TIMx_BDTR Register.

In addition to the break input and the output management, a write protection has been implemented inside the break circuit to safeguard the application. It allows you to freeze the configuration of several parameters (dead-time duration, OCx/OCxN polarities and state when disabled, OCxM configurations, break enable and polarity). You can choose from 3 levels of protection selected by the LOCK bits in the TIMx_BDTR register. Refer to TIM16 break and dead-time register (TIMx_BDTR). The LOCK bits can be written only once after an MCU reset.

The Figure 150 shows an example of behavior of the outputs in response to a break.

Figure 150. Output behavior in response to a break

Timing diagram showing output behavior of OCx and OCxREF in response to a BREAK signal (MOE low) for various timer configurations.

The diagram illustrates the output behavior of OCx and OCxREF in response to a BREAK signal (MOE low) for various timer configurations. The signals are shown as waveforms over time, with vertical lines indicating the timing of the BREAK signal and the resulting output changes. Delays are indicated by double-headed arrows labeled 'delay'.

Signals shown:

MS31098V1

Timing diagram showing output behavior of OCx and OCxREF in response to a BREAK signal (MOE low) for various timer configurations.

21.3.12 Bidirectional break inputs

The TIM16 is featuring bidirectional break I/Os, as represented on Figure 151.

They allow the following:

The break input is configured in bidirectional mode using the BKBID bit in the TIMxBDTR register. The BKBID programming bit can be locked in read-only mode using the LOCK bits in the TIMxBDTR register (in LOCK level 1 or above).

The bidirectional mode requires the I/O to be configured in open-drain mode with active low polarity (using BKINP and BKP bits). Any break request coming from break inputs forces a low level on the break input to signal the fault event. The bidirectional mode is inhibited if the polarity bits are not correctly set (active high polarity), for safety purposes.

The break software event (BG) also causes the break I/O to be forced to '0' to indicate to the external components that the timer has entered in break state. However, this is valid only if the break is enabled (BKE = 1). When a software break event is generated with BKE = 0, the outputs are put in safe state and the break flag is set, but there is no effect on the break I/O.

A safe disarming mechanism prevents the system to be definitively locked-up (a low level on the break input triggers a break which enforces a low level on the same input).

When the BKDSRM bit is set to 1, this releases the break output to clear a fault signal and to give the possibility to re-arm the system.

At no point the break protection circuitry can be disabled:

Table 63. Break protection disarming conditions

MODEBKDIRBKDSRMBreak protection state
00XArmed
010Armed
011Disarmed
1XXArmed

Arming and re-arming break circuitry

The break circuitry (in input or bidirectional mode) is armed by default (peripheral reset configuration).

The following procedure must be followed to re-arm the protection after a break event:

From this point, the break circuitry is armed and active, and the MOE bit can be set to re-enable the PWM outputs.

Figure 151. Output redirection

Block diagram of output redirection logic showing the interaction between break inputs, AF controller, and bidirectional mode control logic.

The diagram illustrates the output redirection logic for a microcontroller's break circuitry. It shows the following components and signal paths:

Block diagram of output redirection logic showing the interaction between break inputs, AF controller, and bidirectional mode control logic.

21.3.13 One-pulse mode

One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.

Generating the waveform can be done in output compare mode or PWM mode. You select One-pulse mode by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.

A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting, the configuration must be:

Figure 152. Example of one pulse mode.

Figure 152: Example of one pulse mode. This timing diagram illustrates the operation of One-Pulse Mode (OPM) for a timer. It shows four signals over time (t): TI1 (trigger input), OC1REF (output compare 1 reference), OC1 (output compare 1), and the Counter value. The Counter starts at 0 and increments in a staircase pattern. A trigger pulse on TI1 initiates the counter. The counter reaches the compare value (TIM1_CCR1) after a delay (t_DELAY), causing OC1 to transition from low to high. The counter continues to increment until it reaches the auto-reload value (TIM1_ARR), at which point it stops. The duration of the high pulse on OC1 is t_PULSE. OC1REF is a constant high level during this period.
Figure 152: Example of one pulse mode. This timing diagram illustrates the operation of One-Pulse Mode (OPM) for a timer. It shows four signals over time (t): TI1 (trigger input), OC1REF (output compare 1 reference), OC1 (output compare 1), and the Counter value. The Counter starts at 0 and increments in a staircase pattern. A trigger pulse on TI1 initiates the counter. The counter reaches the compare value (TIM1_CCR1) after a delay (t_DELAY), causing OC1 to transition from low to high. The counter continues to increment until it reaches the auto-reload value (TIM1_ARR), at which point it stops. The duration of the high pulse on OC1 is t_PULSE. OC1REF is a constant high level during this period.

For example you may want to generate a positive pulse on OC1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\).

The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).

You only want 1 pulse, so you write '1' in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over from the auto-reload value back to 0).

Particular case: OCx fast enable

In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{DELAY\ min}\) we can get.

If you want to output a waveform with the minimum delay, you can set the OCxFE bit in the TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.

21.3.14 Retriggerable one pulse mode (OPM)

This mode allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length, but with the following differences with Non-retriggerable one pulse mode described in Section 21.3.13: One-pulse mode:

The timer must be in Slave mode, with the bits SMS[3:0] = '1000' (Combined Reset + trigger mode) in the TIMx_SMCR register, and the OCxM[3:0] bits set to '1000' or '1001' for Retriggerable OPM mode 1 or 2.

If the timer is configured in Up-counting mode, the corresponding CCRx must be set to 0 (the ARR register sets the pulse length). If the timer is configured in Down-counting mode, CCRx must be above or equal to ARR.

Note: In retriggerable one pulse mode, the CCxIF flag is not significant. The OCxM[3:0] and SMS[3:0] bit fields are split into two parts for compatibility reasons, the most significant bit is not contiguous with the 3 least significant ones. This mode must not be used with center-aligned PWM modes. It is mandatory to have CMS[1:0] = 00 in TIMx_CR1

Figure 153. Retriggerable one pulse mode

Timing diagram for Retriggerable one pulse mode showing TRGI, Counter, and Output signals.

The diagram illustrates the behavior of the timer in Retriggerable one pulse mode. It consists of three horizontal signal traces: TRGI, Counter, and Output.

MS33106V1

Timing diagram for Retriggerable one pulse mode showing TRGI, Counter, and Output signals.

21.3.15 UIF bit remapping

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the Update Interrupt Flag UIF into bit 31 of the timer counter register (TIMxCNT[31]). This allows to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (Update Interrupt).

There is no latency between the assertions of the UIF and UIFCPY flags.

21.3.16 Timer16 and external trigger synchronization

The TIM16 Timer can be synchronized with an external trigger in several modes: Reset mode, Gated mode and Trigger mode.

Slave mode: Reset mode

The counter and its prescaler can be reinitialized in response to an event on a trigger input. Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated. In the following example, the upcounter is cleared in response to a rising edge on TI1 input:

  1. 1. Configure the channel 1 to detect rising edges on TI1. Configure the input filter duration (in this example, we do not need any filter, so we keep IC1F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. The CC1S bits select the input capture source only, CC1S = 01 in the TIMx_CCMR1 register. Write CC1P=0 and CC1NP=0 in TIMx_CCER register to validate the polarity (and detect rising edges only).
  2. 2. Configure the timer in reset mode by writing SMS=100 in TIMx_SMCR register. Select TI1 as the input source by writing TS=00101 in TIMx_SMCR register.
  3. 3. Start the counter by writing CEN=1 in the TIMx_CR1 register.

The counter starts counting on the internal clock, then behaves normally until TI1 rising edge. When TI1 rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request can be sent if enabled (depending on the TIE bit in TIMx_DIER register).

The following figure shows this behavior when the auto-reload register TIMx_ARR=0x36. The delay between the rising edge on TI1 and the actual reset of the counter is due to the resynchronization circuit on TI1 input.

Figure 154. Control circuit in reset mode

Timing diagram for Figure 154: Control circuit in reset mode. It shows five signals: TI1, UG, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a low-level pulse. UG is a short high pulse during the TI1 low period. The counter clock is a continuous square wave. The counter register shows bits 30-36 and 00-03, with the 00-03 bits incrementing during the counter clock pulses while TI1 is low. TIF is a high pulse that occurs when TI1 transitions from low to high.
Timing diagram for Figure 154: Control circuit in reset mode. It shows five signals: TI1, UG, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a low-level pulse. UG is a short high pulse during the TI1 low period. The counter clock is a continuous square wave. The counter register shows bits 30-36 and 00-03, with the 00-03 bits incrementing during the counter clock pulses while TI1 is low. TIF is a high pulse that occurs when TI1 transitions from low to high.

Slave mode: Gated mode

The counter can be enabled depending on the level of a selected input.

In the following example, the upcounter counts only when TI1 input is low:

  1. 1. Configure the channel 1 to detect low levels on TI1. Configure the input filter duration (in this example, we do not need any filter, so we keep IC1F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. The CC1S bits select the input capture source only, CC1S=01 in TIMx_CCMR1 register. Write CC1P=1 and CC1NP=0 in TIMx_CCER register to validate the polarity (and detect low level only).
  2. 2. Configure the timer in gated mode by writing SMS=101 in TIMx_SMCR register. Select TI1 as the input source by writing TS=00101 in TIMx_SMCR register.
  3. 3. Enable the counter by writing CEN=1 in the TIMx_CR1 register (in gated mode, the counter doesn't start if CEN=0, whatever is the trigger input level).

The counter starts counting on the internal clock as long as TI1 is low and stops as soon as TI1 becomes high. The TIF flag in the TIMx_SR register is set both when the counter starts or stops.

The delay between the rising edge on TI1 and the actual stop of the counter is due to the resynchronization circuit on TI1 input.

Figure 155. Control circuit in gated mode

Timing diagram for Figure 155: Control circuit in gated mode. It shows four signals: TI1, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a low-level pulse. CNT_EN is a high-level pulse during the TI1 low period. The counter clock is a continuous square wave. The counter register shows bits 30-33 and 34-38, with the 34-38 bits incrementing during the counter clock pulses while TI1 is low. TIF is a high pulse that occurs when TI1 transitions from low to high. An arrow labeled 'Write TIF=0' points to the TIF signal, indicating it should be cleared.
Timing diagram for Figure 155: Control circuit in gated mode. It shows four signals: TI1, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI1 is a low-level pulse. CNT_EN is a high-level pulse during the TI1 low period. The counter clock is a continuous square wave. The counter register shows bits 30-33 and 34-38, with the 34-38 bits incrementing during the counter clock pulses while TI1 is low. TIF is a high pulse that occurs when TI1 transitions from low to high. An arrow labeled 'Write TIF=0' points to the TIF signal, indicating it should be cleared.
  1. 1. The configuration "CCxP=CCxNP=1" (detection of both rising and falling edges) does not have any effect in gated mode because gated mode acts on a level and not on an edge.

Note: The configuration “CCxP=CCxNP=1” (detection of both rising and falling edges) does not have any effect in gated mode because gated mode acts on a level and not on an edge.

Slave mode: Trigger mode

The counter can start in response to an event on a selected input.

In the following example, the upcounter starts in response to a rising edge on TI2 input:

  1. 1. Configure the channel 2 to detect rising edges on TI2. Configure the input filter duration (in this example, we do not need any filter, so we keep IC2F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. CC2S bits are selecting the input capture source only, CC2S=01 in TIMx_CCMR1 register. Write CC2P=1 and CC2NP=0 in TIMx_CCER register to validate the polarity (and detect low level only).
  2. 2. Configure the timer in trigger mode by writing SMS=110 in TIMx_SMCR register. Select TI2 as the input source by writing TS=00110 in TIMx_SMCR register.

When a rising edge occurs on TI2, the counter starts counting on the internal clock and the TIF flag is set.

The delay between the rising edge on TI2 and the actual start of the counter is due to the resynchronization circuit on TI2 input.

Figure 156. Control circuit in trigger mode

Timing diagram for Figure 156 showing the control circuit in trigger mode. The diagram includes five signals: TI2, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI2 shows a rising edge that triggers the start of the counter. CNT_EN is a high signal. The Counter clock is a square wave starting after the rising edge of TI2. The Counter register shows a value of 34 before the rising edge of TI2, and then increments to 35, 36, 37, and 38. The TIF flag is set high after the counter starts counting.
Timing diagram for Figure 156 showing the control circuit in trigger mode. The diagram includes five signals: TI2, CNT_EN, Counter clock = CK_CNT = CK_PSC, Counter register, and TIF. TI2 shows a rising edge that triggers the start of the counter. CNT_EN is a high signal. The Counter clock is a square wave starting after the rising edge of TI2. The Counter register shows a value of 34 before the rising edge of TI2, and then increments to 35, 36, 37, and 38. The TIF flag is set high after the counter starts counting.

Slave mode – combined reset + trigger mode

In this case, a rising edge of the selected trigger input (TRGI) reinitializes the counter, generates an update of the registers, and starts the counter. This mode is used for one-pulse mode.

21.3.17 Timer synchronization

The TIMx timers are linked together internally for timer synchronization or chaining. When one Timer is configured in Master Mode, it can reset, start, stop or clock the counter of another Timer configured in Slave Mode.

Figure 157 presents an overview of the trigger selection and the master mode selection blocks.

Figure 157. Master/slave timers example

Block diagram of Master/slave timers example showing TIM16 as master and TIM2 as slave.

The diagram illustrates the connection between two timers, TIM16 and TIM2, in a master-slave configuration. TIM16 (Master): A Clock signal enters a Prescaler block, which connects to a Counter block. The Counter outputs an Update Event (UEV) to the Master mode control block. The Master mode control block has an MMS input and a TRGO output. TIM2 (Slave): The TRGO output from TIM16 connects to the ITR0 input of the Input trigger selection block. The Input trigger selection block has TS inputs and connects to the Slave mode control block. The Slave mode control block has an SMS input and a CK_PSC output. The CK_PSC output connects to a Prescaler block, which then connects to a Counter block.

Block diagram of Master/slave timers example showing TIM16 as master and TIM2 as slave.

Using one timer as prescaler for another timer

For example, TIM16 can be configured to act as a prescaler for TIM2. Refer to Figure 157. To do this:

  1. 1. Configure TIM16 in master mode so that it outputs a periodic trigger signal on each update event UEV. If MMS=010 is written in the TIM16_CR2 register, a rising edge is output on TRGO each time an update event is generated.
  2. 2. To connect the TRGO output of TIM16 to TIM2, TIM2 must be configured in slave mode using ITR0 as internal trigger. This is selected through the TS bits in the TIM2_SMCR register (writing TS=00000).
  3. 3. Then the slave mode controller must be put in external clock mode 1 (write SMS=111 in the TIM2_SMCR register). This causes TIM2 to be clocked by the rising edge of the periodic TIM16 trigger signal (which correspond to the TIM16 counter overflow).
  4. 4. Finally both timers must be enabled by setting their respective CEN bits (TIMx_CR1 register).

Note: If OCx is selected on TIM16 as the trigger output (MMS=1xx), its rising edge is used to clock the counter of TIM2.

Using one timer to enable another timer

In this example, we control the enable of TIM2 with the output compare 1 of Timer 2. Refer to Figure 157 for connections. TIM2 counts on the divided internal clock only when OC1REF of TIM16 is high. Both counter clock frequencies are divided by 3 by the prescaler compared to CK_INT (\(f_{CK\_CNT} = f_{CK\_INT}/3\)).

  1. 1. Configure TIM16 master mode to send its Output Compare 1 Reference (OC1REF) signal as trigger output (MMS=100 in the TIM16_CR2 register).
  2. 2. Configure the TIM16 OC1REF waveform (TIM16_CCMR1 register).
  3. 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
  4. 4. Configure TIM2 in gated mode (SMS=101 in TIM2_SMCR register).
  5. 5. Enable TIM2 by writing '1' in the CEN bit (TIM2_CR1 register).
  6. 6. Start TIM16 by writing '1' in the CEN bit (TIM16_CR1 register).

Note: The counter 2 clock is not synchronized with counter 1, this mode only affects the TIM16 counter enable signal.

Figure 158. Gating TIM2 with OC1REF of TIM16

Timing diagram showing the gating of TIM2 by TIM16-OC1REF. The diagram includes five signals: CK_INT (clock), TIM16-OC1REF (gate signal), TIM16-CNT (counting from FC to 01), TIM2-CNT (counting from 3045 to 3048), and TIM2-TIF (trigger flag). The TIM2-TIF signal is high when TIM16-OC1REF is high and TIM2-CNT is at 3046 or 3047. An arrow labeled 'Write TIF=0' points to the falling edge of the TIM2-TIF signal.

The diagram illustrates the gating of TIM2 by TIM16-OC1REF. The CK_INT signal is a continuous clock. The TIM16-OC1REF signal is a pulse that gates the TIM2 counter. The TIM16-CNT signal shows the count sequence: FC, FD, FE, FF, 00, 01. The TIM2-CNT signal shows the count sequence: 3045, 3046, 3047, 3048. The TIM2-TIF signal is high when TIM16-OC1REF is high and TIM2-CNT is at 3046 or 3047. An arrow labeled 'Write TIF=0' points to the falling edge of the TIM2-TIF signal.

Timing diagram showing the gating of TIM2 by TIM16-OC1REF. The diagram includes five signals: CK_INT (clock), TIM16-OC1REF (gate signal), TIM16-CNT (counting from FC to 01), TIM2-CNT (counting from 3045 to 3048), and TIM2-TIF (trigger flag). The TIM2-TIF signal is high when TIM16-OC1REF is high and TIM2-CNT is at 3046 or 3047. An arrow labeled 'Write TIF=0' points to the falling edge of the TIM2-TIF signal.

In the example in Figure 158, the TIM2 counter and prescaler are not initialized before being started. So they start counting from their current value. It is possible to start from a given value by resetting both timers before starting TIM16. Then any value can be written in the timer counters. The timers can easily be reset by software using the UG bit in the TIMx_EGR registers.

In the next example (refer to Figure 159), we synchronize TIM16 and TIM2. TIM16 is the master and starts from 0. TIM2 is the slave and starts from 0xE7. The prescaler ratio is the same for both timers. TIM2 stops when TIM16 is disabled by writing '0 to the CEN bit in the TIM16_CR1 register:

  1. 1. Configure TIM16 master mode to send its Output Compare 1 Reference (OC1REF) signal as trigger output (MMS=100 in the TIM16_CR2 register).
  2. 2. Configure the TIM16 OC1REF waveform (TIM16_CCMR1 register).
  3. 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
  4. 4. Configure TIM2 in gated mode (SMS=101 in TIM2_SMCR register).
  5. 5. Reset TIM16 by writing '1 in UG bit (TIM16_EGR register).
  6. 6. Reset TIM2 by writing '1 in UG bit (TIM2_EGR register).
  7. 7. Initialize TIM2 to 0xE7 by writing '0xE7' in the TIM2 counter (TIM2_CNTL).
  8. 8. Enable TIM2 by writing '1 in the CEN bit (TIM2_CR1 register).
  9. 9. Start TIM16 by writing '1 in the CEN bit (TIM16_CR1 register).
  10. 10. Stop TIM16 by writing '0 in the CEN bit (TIM16_CR1 register).

Figure 159. Gating TIM2 with Enable of TIM16

Timing diagram for Figure 159 showing the gating of TIM2 with the enable of TIM16. The diagram includes signals: CK_INT (clock), TIM16-CEN=CNT_EN (enable), TIM16-CNT_INIT (init), TIM16-CNT (counter), TIM2-CNT (counter), TIM2-CNT_INIT (init), TIM2 (write CNT), and TIM2-TIF (trigger flag).

The diagram illustrates the timing relationship between TIM16 and TIM2. CK_INT is a continuous clock signal. TIM16-CEN=CNT_EN is a high signal that enables TIM16. TIM16-CNT_INIT is a pulse that initializes TIM16. TIM16-CNT shows the counter values: 75, 00, 01, 02. TIM2-CNT shows the counter values: AB, 00, E7, E8, E9. TIM2-CNT_INIT is a pulse that initializes TIM2. TIM2 (write CNT) is a pulse that writes the counter value. TIM2-TIF is a pulse that indicates a trigger flag. An arrow labeled 'Write TIF=0' points to the TIM2-TIF signal.

Timing diagram for Figure 159 showing the gating of TIM2 with the enable of TIM16. The diagram includes signals: CK_INT (clock), TIM16-CEN=CNT_EN (enable), TIM16-CNT_INIT (init), TIM16-CNT (counter), TIM2-CNT (counter), TIM2-CNT_INIT (init), TIM2 (write CNT), and TIM2-TIF (trigger flag).

Using one timer to start another timer

In this example, we set the enable of Timer 2 with the update event of Timer 16. Refer to Figure 157 for connections. Timer 2 starts counting from its current value (which can be non-zero) on the divided internal clock as soon as the update event is generated by Timer 16.

When Timer 2 receives the trigger signal its CEN bit is automatically set and the counter counts until we write '0 to the CEN bit in the TIM2_CR1 register. Both counter clock frequencies are divided by 3 by the prescaler compared to CK_INT (\(f_{CK\_CNT} = f_{CK\_INT}/3\)).

  1. 1. Configure TIM16 master mode to send its Update Event (UEV) as trigger output (MMS=010 in the TIM16_CR2 register).
  2. 2. Configure the TIM16 period (TIM16_ARR registers).
  3. 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
  4. 4. Configure TIM2 in trigger mode (SMS=110 in TIM2_SMCR register).
  5. 5. Start TIM16 by writing '1 in the CEN bit (TIM16_CR1 register).

Figure 160. Triggering TIM2 with update of TIM16

Timing diagram for Figure 160 showing the triggering of TIM2 with the update of TIM16. The diagram includes signals: CK_INT (clock), TIM16-UEV (update event), TIM16-CNT (counter), TIM2-CNT (counter), TIM2-CEN=CNT_EN (enable), and TIM2-TIF (trigger flag).

The diagram illustrates the timing relationship between TIM16 and TIM2. CK_INT is a continuous clock signal. TIM16-UEV is a pulse that triggers TIM2. TIM16-CNT shows the counter values: FD, FE, FF, 00, 01, 02. TIM2-CNT shows the counter values: 45, 46, 47, 48. TIM2-CEN=CNT_EN is a high signal that enables TIM2. TIM2-TIF is a pulse that indicates a trigger flag. An arrow labeled 'Write TIF=0' points to the TIM2-TIF signal.

Timing diagram for Figure 160 showing the triggering of TIM2 with the update of TIM16. The diagram includes signals: CK_INT (clock), TIM16-UEV (update event), TIM16-CNT (counter), TIM2-CNT (counter), TIM2-CEN=CNT_EN (enable), and TIM2-TIF (trigger flag).

As in the previous example, both counters can be initialized before starting counting.

Figure 161 shows the behavior with the same configuration as in Figure 160 but in trigger mode instead of gated mode (SMS=110 in the TIM2_SMCR register).

Figure 161. Triggering TIM2 with Enable of TIM16

Timing diagram showing the interaction between TIM16 and TIM2 in trigger mode. CK_INT is a continuous clock. TIM16-CEN=CNT_EN is a high pulse that enables TIM16. TIM16-CNT_INIT is a low pulse that initializes TIM16. TIM16-CNT shows values 75, 00, 01, 02. TIM2-CNT shows values CD, 00, E7, E8, E9, EA. TIM2-CNT_INIT is a low pulse that initializes TIM2. TIM2-write CNT is a low pulse that writes the current count to TIM2. TIM2-TIF is a low pulse that indicates a trigger event. An arrow points to the start of the TIM2-TIF pulse with the label 'Write TIF=0'.
Timing diagram showing the interaction between TIM16 and TIM2 in trigger mode. CK_INT is a continuous clock. TIM16-CEN=CNT_EN is a high pulse that enables TIM16. TIM16-CNT_INIT is a low pulse that initializes TIM16. TIM16-CNT shows values 75, 00, 01, 02. TIM2-CNT shows values CD, 00, E7, E8, E9, EA. TIM2-CNT_INIT is a low pulse that initializes TIM2. TIM2-write CNT is a low pulse that writes the current count to TIM2. TIM2-TIF is a low pulse that indicates a trigger event. An arrow points to the start of the TIM2-TIF pulse with the label 'Write TIF=0'.

Note: The clock of the slave peripherals (timer, DAC, and so on) receiving the TRGO signal must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

21.3.18 DMA burst mode

The TIMx timers have the capability to generate multiple DMA requests on a single event. The main purpose is to be able to re-program several timer registers multiple times without software overhead, but it can also be used to read several registers in a row, at regular intervals.

The DMA controller destination is unique and must point to the virtual register TIMx_DMAR. On a given timer event, the timer launches a sequence of DMA requests (burst). Each write into the TIMx_DMAR register is actually redirected to one of the timer registers.

The DBL[4:0] bits in the TIMx_DCR register set the DMA burst length. The timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address, i.e. the number of transfers (either in half-words or in bytes).

The DBA[4:0] bits in the TIMx_DCR registers define the DMA base address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.

Example:

00000: TIMx_CR1,

00001: TIMx_CR2,

For example, the timer DMA burst feature could be used to update the contents of the CCRx registers (x = 2, 3, 4) on an update event, with the DMA transferring half words into the CCRx registers.

This is done in the following steps:

  1. 1. Configure the corresponding DMA channel as follows:
    • – DMA channel peripheral address is the DMAR register address
    • – DMA channel memory address is the address of the buffer in the RAM containing the data to be transferred by DMA into the CCRx registers.
    • – Number of data to transfer = 3 (See note below).
    • – Circular mode disabled.
  2. 2. Configure the DCR register by configuring the DBA and DBL bit fields as follows:
    DBL = 3 transfers, DBA = 0xE.
  3. 3. Enable the TIMx update DMA request (set the UDE bit in the DIER register).
  4. 4. Enable TIMx
  5. 5. Enable the DMA channel

This example is for the case where every CCRx register is to be updated once. If every CCRx register is to be updated twice for example, the number of data to transfer should be 6. Let's take the example of a buffer in the RAM containing data1, data2, data3, data4, data5 and data6. The data is transferred to the CCRx registers as follows: on the first update DMA request, data1 is transferred to CCR2, data2 is transferred to CCR3, data3 is transferred to CCR4 and on the second update DMA request, data4 is transferred to CCR2, data5 is transferred to CCR3 and data6 is transferred to CCR4.

21.3.19 Debug mode

When the system enters debug mode (processor core halted), the TIMx counter either continues to work normally or stops, depending on DBG_TIM16_STOP configuration bit in DBGMCU module. For more details, refer to Section 30.3.2: DBG APB0 freeze register (DBG_APB0_FZ).

21.4 TIM16 registers

Refer to Section 1.1: List of abbreviations for registers for a list of abbreviations used in register descriptions.

21.4.1 TIM16 control register 1 (TIMx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
ResResResResUIF
REM-
AP
ResCKD[1:0]ARPEResResResOPMURSUDISCEN
rwrwrwrwrwrwrwrw

Bits 15:12 Reserved, must be kept at reset value.

Bit 11 UIFREMAP: UIF status bit remapping

0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.

1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.

Bit 10 Reserved, must be kept at reset value.

Bits 9:8 CKD[1:0]: Clock division

This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (\(t_{DTS}\)) used by the dead-time generators and the digital filters (TIx),

00: \(t_{DTS}=t_{CK\_INT}\)

01: \(t_{DTS}=2*t_{CK\_INT}\)

10: \(t_{DTS}=4*t_{CK\_INT}\)

11: Reserved, do not program this value

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered

1: TIMx_ARR register is buffered

Bits 6:4 Reserved, must be kept at reset value.

Bit 3 OPM: One pulse mode

0: Counter is not stopped at update event

1: Counter stops counting at the next update event (clearing the bit CEN)

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

0: Any of the following events generate an update interrupt or DMA request if enabled.

These events can be:

1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

0: UEV enabled. The Update (UEV) event is generated by one of the following events:

Buffered registers are then loaded with their preload values.

1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC, CCRx). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

Note: External clock and gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.

21.4.2 TIM16 control register 2 (TIMx_CR2)

Address offset: 0x04

Reset value: 0x0000

1514131211109876543210
ResResResResResResOIS1NOIS1TI1SMMS[2:0]CCDSCCUSResCCPC
rwrwrwrwrwrwrwrwrw

Bits 15:10 Reserved, must be kept at reset value.

Bit 9 OIS1N: Output Idle state 1 (OC1N output)

0: OC1N=0 after a dead-time when MOE=0

1: OC1N=1 after a dead-time when MOE=0

Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BKR register).

Bit 8 OIS1: Output Idle state 1 (OC1 output)

0: OC1=0 (after a dead-time if OC1N is implemented) when MOE=0

1: OC1=1 (after a dead-time if OC1N is implemented) when MOE=0

Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BKR register).

Bit 7 TI1S: TI1 selection

0: The TIMx_CH1 pin is connected to TI1 input

1: Reserved

Bits 6:4 MMS[2:0]: Master mode selection

These bits allow to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:

000: Reset - the UG bit from the TIMx_EGR register is used as trigger output (TRGO). If the reset is generated by the trigger input (slave mode controller configured in reset mode) then the signal on TRGO is delayed compared to the actual reset.

001: Enable - the Counter Enable signal CNT_EN is used as trigger output (TRGO). It is useful to start several timers at the same time or to control a window in which a slave timer is enable. The Counter Enable signal is generated by a logic OR between CEN control bit and the trigger input when configured in gated mode. When the Counter Enable signal is controlled by the trigger input, there is a delay on TRGO, except if the master/slave mode is selected (see the MSM bit description in TIMx_SMCR register).

010: Update - The update event is selected as trigger output (TRGO). For instance a master timer can then be used as a prescaler for a slave timer.

011: Compare Pulse - The trigger output send a positive pulse when the CC1IF flag is to be set (even if it was already high), as soon as a capture or a compare match occurred. (TRGO).

100: Compare - OC1REF signal is used as trigger output (TRGO).

Bit 3 CCDS: Capture/compare DMA selection

0: CCx DMA request sent when CCx event occurs

1: CCx DMA requests sent when update event occurs

Bit 2 CCUS: Capture/compare control update selection

0: When capture/compare control bits are preloaded (CCPC=1), they are updated by setting the COMG bit only.

1: When capture/compare control bits are preloaded (CCPC=1), they are updated by setting the COMG bit or when an rising edge occurs on TRGI.

Note: This bit acts only on channels that have a complementary output.

Bit 1 Reserved, must be kept at reset value.

Bit 0 CCPC: Capture/compare preloaded control

0: CCxE, CCxNE and OCxM bits are not preloaded

1: CCxE, CCxNE and OCxM bits are preloaded, after having been written, they are updated only when COM bit is set.

Note: This bit acts only on channels that have a complementary output.

21.4.3 TIM16 slave mode control register (TIM16_SMCR)

Address offset: 0x08

Reset value: 0x0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TS[4:3]Res.Res.Res.SMS[3]
rwrwrw
1514131211109876543210
MSMTS[2:0]Res.SMS[2:0]
rwrwrwrwrwrwrw

Bit 31:22 Reserved, must be kept at reset value.

Bit 19:18 Reserved, must be kept at reset value.

Bit 7 MSM: Master/slave mode

0: No action

1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect synchronization between the current timer and its slaves (through TRGO). It is useful if we want to synchronize several timers on a single external event.

Bits 21,20, 6:4 TS[4:0]: Trigger selection

This bitfield selects the trigger input to be used to synchronize the counter.

00000: Internal Trigger 0 (ITR0)

00001: Internal Trigger 1 (ITR1)

00010: Internal Trigger 2 (ITR2)

00011: Internal Trigger 3 (ITR3)

00100: TI1 Edge Detector (TI1F_ED)

00101: Filtered Timer Input 1 (TI1FP1)

Other codes: Reserved

Note: These bits must be changed only when they are not used (e.g. when SMS=000) to avoid wrong edge detections at the transition.

See Table 66: TIM16 register map and reset values for more details on ITRx meaning for each Timer.

Bit 3 Reserved, must be kept at reset value.

Bits16, 2:0 SMS[3:0]: Slave mode selection

When external signals are selected the active edge of the trigger signal (TRGI) is linked to the polarity selected on the external input (see Input Control register and Control Register description).

0000: Slave mode disabled - if CEN = '1' then the prescaler is clocked directly by the internal clock.

0100: Reset Mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter and generates an update of the registers.

0101: Gated Mode - The counter clock is enabled when the trigger input (TRGI) is high. The counter stops (but is not reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.

0110: Trigger Mode - The counter starts at a rising edge of the trigger TRGI (but it is not reset). Only the start of the counter is controlled.

0111: External Clock Mode 1 - Rising edges of the selected trigger (TRGI) clock the counter.

1000: Combined reset + trigger mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter, generates an update of the registers and starts the counter.

Other codes: Reserved

Note: The gated mode must not be used if TI1F_ED is selected as the trigger input (TS='00100'). Indeed, TI1F_ED outputs 1 pulse for each transition on TI1F, whereas the gated mode checks the level of the trigger signal.

Note: The clock of the slave peripherals (timer16, DAC) receiving the TRGO signal must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

Table 64. TIM16 internal trigger connection

Slave TIMITR0ITR1ITR2 - ITR8
TIM16TIM2--

21.4.4 TIM16 DMA/interrupt enable register (TIMx_DIER)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
ResTDEResResResResCC1DEUDEBIETIECOMIEResResResCC1IEUIE
rwrwrwrwrwrwrwrw

Bit 15:13 Reserved, must be kept at reset value.

Bit 14 TDE: Trigger DMA request enable

0: Trigger DMA request disabled

1: Trigger DMA request enabled

Bit 9 CC1DE: Capture/Compare 1 DMA request enable

0: CC1 DMA request disabled

1: CC1 DMA request enabled

Bit 8 UDE: Update DMA request enable

0: Update DMA request disabled

1: Update DMA request enabled

Bit 7 BIE: Break interrupt enable

0: Break interrupt disabled

1: Break interrupt enabled

Bit 6 TIE: Trigger interrupt enable

0: Trigger interrupt disabled

1: Trigger interrupt enabled

Bit 5 COMIE: COM interrupt enable

0: COM interrupt disabled

1: COM interrupt enabled

Bits 4:2 Reserved, must be kept at reset value.

Bit 1 CC1IE: Capture/Compare 1 interrupt enable

0: CC1 interrupt disabled

1: CC1 interrupt enabled

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled

1: Update interrupt enabled

21.4.5 TIM16 status register (TIMx_SR)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
ResResResResResResCC1OFResBIFTIFCOMIFResResResCC1IFUIF
rc_w0rc_w0rc_w0rc_w0rc_w0rc_w0

Bits 15:10 Reserved, must be kept at reset value.

Bit 9 CC1OF: Capture/Compare 1 overcapture flag

This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.

0: No overcapture has been detected

1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set

Bit 8 Reserved, must be kept at reset value.

Bit 7 BIF: Break interrupt flag

This flag is set by hardware as soon as the break input goes active. It can be cleared by software if the break input is not active.

0: No break event occurred

1: An active level has been detected on the break input

Bit 6 TIF: Trigger interrupt flag

This flag is set by hardware on trigger event (active edge detected on TRGI input when the slave mode controller is enabled in all modes but gated mode, both edges in case gated mode is selected). It is cleared by software.

0: No trigger event occurred

1: Trigger interrupt pending

Bit 5 COMIF: COM interrupt flag

This flag is set by hardware on a COM event (once the capture/compare control bits –CCxE, CCxNE, OCxM– have been updated). It is cleared by software.

0: No COM event occurred

1: COM interrupt pending

Bits 4:2 Reserved, must be kept at reset value.

Bit 1 CC1IF: Capture/Compare 1 interrupt flag

If channel CC1 is configured as output:

This flag is set by hardware when the counter matches the compare value. It is cleared by software.

0: No match.

1: The content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register. When the contents of TIMx_CCR1 are greater than the contents of TIMx_ARR, the CC1IF bit goes high on the counter overflow

If channel CC1 is configured as input:

This bit is set by hardware on a capture. It is cleared by software or by reading the TIMx_CCR1 register.

0: No input capture occurred

1: The counter value has been captured in TIMx_CCR1 register (An edge has been detected on IC1 which matches the selected polarity)

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

21.4.6 TIM16 event generation register (TIMx_EGR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
ResResResResResResResResBGTGCOMGResResResCC1GUG
wwwww

Bits 15:8 Reserved, must be kept at reset value.

Bit 7 BG: Break generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action.

1: A break event is generated. MOE bit is cleared and BIF flag is set. Related interrupt or DMA transfer can occur if enabled.

Bit 6 TG: Trigger generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action

1: The TIF flag is set in TIMx_SR register. Related interrupt or DMA transfer can occur if enabled

Bit 5 COMG: Capture/Compare control update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action

1: When the CCPC bit is set, it is possible to update the CCxE, CCxNE and OCxM bits

Note: This bit acts only on channels that have a complementary output.

Bits 4:2 Reserved, must be kept at reset value.

Bit 1 CC1G: Capture/Compare 1 generation

This bit is set by software in order to generate an event, it is automatically cleared by hardware.

0: No action.

1: A capture/compare event is generated on channel 1:

If channel CC1 is configured as output:

CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled.

If channel CC1 is configured as input:

The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action.

1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected).

21.4.7 TIM16 capture/compare mode register 1 (TIMx_CCMR1)

Address offset: 0x18

Reset value: 0x0000

The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function in input and in output mode. For a given bit, OCxx describes its function when the channel is configured in output, ICxx describes its function when the channel is configured in input. So you must take care that the same bit can have a different meaning for the input stage and for the output stage.

31302928272625242322212019181716
ResResResResResResResResResResResResResResResOC1M [3]
Res.
rw
1514131211109876543210
ResResResResResResResResResOC1M[2:0]OC1PEOC1FECC1S[1:0]
IC1F[3:0]IC1PSC[1:0]
rwrwrwrwrwrwrw
ST logo
ST logo

Output compare mode:

Bits 31:17 Reserved, always read as 0

Bits 16, 6:4 OC1M[3:0]: Output Compare 1 mode (bits 3 to 0)

These bits define the behavior of the output reference signal OC1REF from which OC1 and OC1N are derived. OC1REF is active high whereas OC1 and OC1N active level depends on CC1P and CC1NP bits.

00000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.

00001: Set channel 1 to active level on match. OC1REF signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

00010: Set channel 1 to inactive level on match. OC1REF signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).

00011: Toggle - OC1REF toggles when TIMx_CNT=TIMx_CCR1.

00100: Force inactive level - OC1REF is forced low.

00101: Force active level - OC1REF is forced high.

00110: PWM mode 1 - Channel 1 is active as long as TIMx_CNT<TIMx_CCR1 else inactive.

00111: PWM mode 2 - Channel 1 is inactive as long as TIMx_CNT<TIMx_CCR1 else active.

1000: Retriggerable OPM mode 1 - In up-counting mode, the channel is active until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update.

1001: Retriggerable OPM mode 2 - In up-counting mode, the channel is inactive until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 2 and the channels becomes inactive again at the next update.

All other values: Reserved

Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

2: In PWM mode 1 or 2, the OCREF level changes only when the result of the comparison changes or when the output compare mode switches from "frozen" mode to "PWM" mode.

Bit 3 OC1PE: Output Compare 1 preload enable

0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.

1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.

Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).

2: The PWM mode can be used without validating the preload register only in one pulse mode (OPM bit set in TIMx_CR1 register). Else the behavior is not guaranteed.

Bit 2 OC1FE: Output Compare 1 fast enable

This bit is used to accelerate the effect of an event on the trigger in input on the CC output.
0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.

1: An active edge on the trigger input acts like a compare match on CC1 output. Then, OC is set to the compare level independently of the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OC1FE acts only if the channel is configured in PWM1 or PWM2 mode.

Bits 1:0 CC1S: Capture/Compare 1 selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1:

1x: Reserved

Note: CC1S bits are writable only when the channel is OFF (CC1E = '0' in TIMx_CCER).

Input capture mode

Bits 31:8 Reserved, must be kept at reset value.

Bits 7:4 IC1F[3:0]: Input capture 1 filter

This bit-field defines the frequency used to sample TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N events are needed to validate a transition on the output:

0000: No filter, sampling is done at fDTS

0001: fSAMPLING=fCK_INT, N=2

0010: fSAMPLING=fCK_INT, N=4

0011: fSAMPLING=fCK_INT, N=8

0100: fSAMPLING=fDTS/2, N=

0101: fSAMPLING=fDTS/2, N=8

0110: fSAMPLING=fDTS/4, N=6

0111: fSAMPLING=fDTS/4, N=8

1000: fSAMPLING=fDTS/8, N=6

1001: fSAMPLING=fDTS/8, N=8

1010: fSAMPLING=fDTS/16, N=5

1011: fSAMPLING=fDTS/16, N=6

1100: fSAMPLING=fDTS/16, N=8

1101: fSAMPLING=fDTS/32, N=5

1110: fSAMPLING=fDTS/32, N=6

1111: fSAMPLING=fDTS/32, N=8

Bits 3:2 IC1PSC: Input capture 1 prescaler

This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).

The prescaler is reset as soon as CC1E=’0’ (TIMx_CCER register).

00: no prescaler, capture is done each time an edge is detected on the capture input.

01: capture is done once every 2 events

10: capture is done once every 4 events

11: capture is done once every 8 events

Bits 1:0 CC1S: Capture/Compare 1 Selection

This bit-field defines the direction of the channel (input/output) as well as the used input.

00: CC1 channel is configured as output

01: CC1 channel is configured as input, IC1 is mapped on TI1

1x: Reserved

Note: CC1S bits are writable only when the channel is OFF (CC1E = ’0’ in TIMx_CCER).

21.4.8 TIM16 capture/compare enable register (TIMx_CCER)

Address offset: 0x20

Reset value: 0x0000

1514131211109876543210
ResResResResResResResResResResResResCC1NPCC1NECC1PCC1E
rwrwrwrw

Bits 15:4 Reserved, must be kept at reset value.

Bit 3 CC1NP: Capture/Compare 1 complementary output polarity

CC1 channel configured as output:

0: OC1N active high

1: OC1N active low

CC1 channel configured as input:

This bit is used in conjunction with CC1P to define the polarity of TI1FP1. Refer to the description of CC1P.

Note: 1. This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S="00" (the channel is configured in output).

2. On channels that have a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1NP active bit takes the new value from the preloaded bit only when a commutation event is generated.

Bit 2 CC1NE: Capture/Compare 1 complementary output enable

0: Off - OC1N is not active. OC1N level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.

1: On - OC1N signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.

Bit 1 CC1P: Capture/Compare 1 output polarity

CC1 channel configured as output:

0: OC1 active high

1: OC1 active low

CC1 channel configured as input:

The CC1NP/CC1P bits select the polarity of TI1FP1 for trigger or capture operations.

00: Non-inverted/rising edge. The circuit is sensitive to TIxFP1 rising edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode).

01: Inverted/falling edge. The circuit is sensitive to TIxFP1 falling edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is inverted (trigger operation in gated mode).

10: Reserved, do not use this configuration.

11: Non-inverted/both edges. The circuit is sensitive to both TIxFP1 rising and falling edges (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode).

Note: 1. This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

2. On channels that have a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1P active bit takes the new value from the preloaded bit only when a Commutation event is generated.

Bit 0 CC1E: Capture/Compare 1 output enable

CC1 channel configured as output:

0: Off - OC1 is not active. OC1 level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.

1: On - OC1 signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.

CC1 channel configured as input:

This bit determines if a capture of the counter value can actually be done into the input capture/compare register 1 (TIMx_CCR1) or not.

0: Capture disabled

1: Capture enabled

Table 65. Output control bits for complementary OCx and OCxN channels with break feature

Control bitsOutput states(1)
MOE bitOSSI bitOSSR bitCCxE bitCCxNE bitOCx output stateOCxN output state
1XX00Output Disabled (not driven by the timer: Hi-Z)
OCx=0
OCxN=0, OCxN_EN=0
001Output Disabled (not driven by the timer: Hi-Z)
OCx=0
OCxREF + Polarity
OCxN=OCxREF XOR CCxNP
010OCxREF + Polarity
OCx=OCxREF XOR CCxP
Output Disabled (not driven by the timer: Hi-Z)
OCxN=0
X11OCREF + Polarity + dead-timeComplementary to OCREF (not OCREF) + Polarity + dead-time
101Off-State (output enabled with inactive state)
OCx=CCxP
OCxREF + Polarity
OCxN=OCxREF XOR CCxNP
110OCxREF + Polarity
OCx=OCxREF XOR CCxP,
OCx_EN=1
Off-State (output enabled with inactive state)
OCxN=CCxNP, OCxN_EN=1
00XXXOutput Disabled (not driven by the timer: Hi-Z)
OCx=CCxP, OCxN=CCxNP
100Off-State (output enabled with inactive state)
OCx=CCxP, OCxN=CCxNP
01Off-State (output enabled with inactive state)
Asynchronously: OCx=CCxP, OCxN=CCxNP
10Then if the clock is present: OCx=OISx and OCxN=OISxN
after a dead-time, assuming that OISx and OISxN do not correspond to OCx and OCxN both in active state
11

1. When both outputs of a channel are not used (control taken over by GPIO controller), the OISx, OISxN, CCxP and CCxNP bits must be kept cleared.

Note: The state of the external I/O pins connected to the complementary OCx and OCxN channels depends on the OCx and OCxN channel state and AFIO registers.

21.4.9 TIM16 counter (TIMx_CNT)

Address offset: 0x24

Reset value: 0x0000

31302928272625242322212019181716
UIF
CPY
ResResResResResResResResResResResResResResRes
r
1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 31 UIFCPY: UIF Copy

This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.

Bits 30:16 Reserved, must be kept at reset value.

Bits 15:0 CNT[15:0]: Counter value

21.4.10 TIM16 prescaler (TIMx_PSC)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency (CK_CNT) is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).

21.4.11 TIM16 auto-reload register (TIMx_ARR)

Address offset: 0x2C

Reset value: 0xFFFF

1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 ARR[15:0]: Prescaler value

ARR is the value to be loaded in the actual auto-reload register.

Refer to the Section 21.3.1: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

21.4.12 TIM16 repetition counter register (TIMx_RCR)

Address offset: 0x30

Reset value: 0x0000

1514131211109876543210
ResResResResResResResResREP[7:0]
rwrwrwrwrwrwrwrw

Bits 15:8 Reserved, must be kept at reset value.

Bits 7:0 REP[7:0]: Repetition counter value

These bits allow the user to set-up the update rate of the compare registers (i.e. periodic transfers from preload to active registers) when preload registers are enable, as well as the update interrupt generation rate, if this interrupt is enable.

Each time the REP_CNT related downcounter reaches zero, an update event is generated and it restarts counting from REP value. As REP_CNT is reloaded with REP value only at the repetition update event U_RC, any write to the TIMx_RCR register is not taken in account until the next repetition update event.

It means in PWM mode (REP+1) corresponds to the number of PWM periods in edge-aligned mode.

21.4.13 TIM16 capture/compare register 1 (TIMx_CCR1)

Address offset: 0x34

Reset value: 0x0000

1514131211109876543210
CCR1[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CCR1[15:0]: Capture/Compare 1 value

If channel CC1 is configured as output:

CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value).

It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs.

The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on OC1 output.

If channel CC1 is configured as input:

CCR1 is the counter value transferred by the last input capture 1 event (IC1).

21.4.14 TIM16 break and dead-time register (TIMx_BDTR)

Address offset: 0x44

Reset value: 0x0000

31302928272625242322212019181716
ResResResBKBIDResBKDSRMResResResResResResResResResRes
rwrw
1514131211109876543210
MOEAOEBKPBKEOSSROSSILOCK[1:0]DTG[7:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Note: As the BKBID, BKDSRM, AOE, BKP, BKE, OSSI, OSSR, DTG[7:0] bits and all used bits of TIMx_AF1 register may be write-locked depending on the LOCK configuration, it may be necessary to configure all of them during the first write access to the TIMx_BDTR register.

Bits 31:29 Reserved, must be kept at reset value.

Bit 28 BKBID: Break Bidirectional

0: Break input BRK in input mode

1: Break input BRK in bidirectional mode

In the bidirectional mode (BKBID bit set to 1), the break input is configured both in input mode and in open drain output mode. Any active break event asserts a low logic level on the Break input to indicate an internal break event to external devices.

Note: This bit cannot be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bit 27 Reserved, must be kept at reset value.

Bit 26 BKDSRM: Break Disarm

0: Break input BRK is armed

1: Break input BRK is disarmed

This bit is cleared by hardware when no break source is active.

The BKDSRM bit must be set by software to release the bidirectional output control (opendrain output in Hi-Z state) and then be polled it until it is reset by hardware, indicating that the fault condition has disappeared.

Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.

Bits 25:16 Reserved, must be kept at reset value.

Bit 15 MOE: Main output enable

This bit is cleared asynchronously by hardware as soon as the break input is active. It is set by software or automatically depending on the AOE bit. It is acting only on the channels which are configured in output.

0: OC and OCN outputs are disabled or forced to idle state depending on the OSSI bit.

1: OC and OCN outputs are enabled if their respective enable bits are set (CCxE, CCxNE in TIMx_CCER register)

See OC/OCN enable description for more details (Section 21.4.8: TIM16 capture/compare enable register (TIMx_CCER)).

Bit 10 OSSI: Off-state selection for Idle mode

This bit is used when MOE=0 on channels configured as outputs.

See OC/OCN enable description for more details (Section 21.4.8: TIM16 capture/compare enable register (TIMx_CCER)).

0: When inactive, OC/OCN outputs are disabled (OC/OCN enable output signal=0)

1: When inactive, OC/OCN outputs are forced first with their idle level as soon as CCxE=1 or CCxNE=1. OC/OCN enable output signal=1)

Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).

Bits 9:8 LOCK[1:0]: Lock configuration

These bits offer a write protection against software errors.

00: LOCK OFF - No bit is write protected

01: LOCK Level 1 = DTG bits in TIMx_BDTR register, OISx and OISxN bits in TIMx_CR2 register, BKE/BKP/AOE/BKBID/BKDSRM bits in TIMx_BDTR register and all used bits in TIMx_AF1 register can no longer be written.

10: LOCK Level 2 = LOCK Level 1 + CC Polarity bits (CCxP/CCxNP bits in TIMx_CCER register, as long as the related channel is configured in output through the CCxS bits) as well as OSSR and OSSI bits can no longer be written.

11: LOCK Level 3 = LOCK Level 2 + CC Control bits (OCxM and OCxPE bits in TIMx_CCMRx registers, as long as the related channel is configured in output through the CCxS bits) can no longer be written.

Note: The LOCK bits can be written only once after the reset. Once the TIMx_BDTR register has been written, their content is frozen until the next reset.

Bits 7:0 DTG[7:0]: Dead-time generator setup

This bit-field defines the duration of the dead-time inserted between the complementary outputs. DT correspond to this duration.

\(DTG[7:5]=0xx \Rightarrow DT=DTG[7:0] \times t_{dtg}\) with \(t_{dtg}=t_{DTS}\)

\(DTG[7:5]=10x \Rightarrow DT=(64+DTG[5:0]) \times t_{dtg}\) with \(T_{dtg}=2 \times t_{DTS}\)

\(DTG[7:5]=110 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=8 \times t_{DTS}\)

\(DTG[7:5]=111 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=16 \times t_{DTS}\)

Example if \(T_{DTS}=125\) ns (8 MHz), dead-time possible values are:

0 to 15875 ns by 125 ns steps,

16 μs to 31750 ns by 250 ns steps,

32 μs to 63 μs by 1 μs steps,

64 μs to 126 μs by 2 μs steps

Note: This bit-field can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).

21.4.15 TIM16 DMA control register (TIMx_DCR)

Address offset: 0x48

Reset value: 0x0000

1514131211109876543210
ResResResDBL[4:0]ResResResDBA[4:0]
rwrwrwrwrwrwrwrwrwrw

Bits 15:13 Reserved, must be kept at reset value.

Bits 12:8 DBL[4:0]: DMA burst length

This 5-bit field defines the length of DMA transfers (the timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address), i.e. the number of transfers. Transfers can be in half-words or in bytes (see example below).

00000: 1 transfer,
00001: 2 transfers,
00010: 3 transfers,
...
10001: 18 transfers.

Bits 7:5 Reserved, must be kept at reset value.

Bits 4:0 DBA[4:0]: DMA base address

This 5-bit field defines the base-address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.

Example:

00000: TIMx_CR1,
00001: TIMx_CR2,
00010: Reserved,
...

Example: Let us consider the following transfer: DBL = 7 transfers and DBA = TIMx_CR1. In this case the transfer is done to/from 7 registers starting from the TIMx_CR1 address.

21.4.16 TIM16 DMA address for full transfer (TIMx_DMAR)

Address offset: 0x4C

Reset value: 0x0000

1514131211109876543210
DMAB[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 DMAB[15:0]: DMA register for burst accesses

A read or write operation to the DMAR register accesses the register located at the address
\((\text{TIMx\_CR1 address}) + (\text{DBA} + \text{DMA index}) \times 4\)

where TIMx_CR1 address is the address of the control register 1, DBA is the DMA base address configured in TIMx_DCR register, DMA index is automatically controlled by the DMA transfer, and ranges from 0 to DBL (DBL configured in TIMx_DCR).

21.4.17 TIM16 option register 1 (TIM16_OR)

Address offset: 0x50

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TI1_RMP[1:0]Res.
rwrw

Bits 31:3 Reserved, must be kept at reset value.

Bits 2:1 TI1_RMP[1:0]: Timer 16 input 1 connection
This bit is set and cleared by software.
00: TIM16 TI1 is connected to GPIO
01: TIM16 TI1 is connected to LCO
10: TIM16 TI1 is connected to COMP_OUT (STM32WL33xx only)
11: TIM16 TI1 is connected to MCO

Bit 0 Reserved, must be kept at reset value.

ST logo
ST logo

21.4.18 TIM16 alternate function option register 2 (TIMx_AF1)

Address offset: 0x60

Reset value: 0x0001

31302928272625242322212019181716
ResResResResResResResResResResResResResResResRes
1514131211109876543210
ResResResResResBKCM
P1P
BKINPResResResResResResResBKCM
P1E
BKINE
rwrwrwrw
1514131211109876543210

Bits 31:11 Reserved, must be kept at reset value.

Bit 10 BKCMP1P: BRK COMP1 input polarity (STM32WL33xx only) .

This bit selects the COMP1 input sensitivity. It must be programmed together with the BKP polarity bit.

0: COMP1 input is active low.

1: COMP1 input is active high.

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)

Bit 9 BKINP: BRK BKIN input polarity.

This bit selects the BKIN alternate function input sensitivity. It must be programmed together with the BKP polarity bit.

0: BKIN input is active low.

1: BKIN input is active high.

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)

Bits 8:2 Reserved, must be kept at reset value.

Bit 1 BKCMP1E: BRK COMP1 enable (STM32WL33xx only).

This bit enables the COMP1 for the timer's BRK input. COMP1 output is ORed with the other enabled BRK sources.

0: COMP1 input disabled.

1: COMP1 input enabled.

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)

Bit 0 BKINE: BRK BKIN enable.

This bit enables the BKIN alternate function input for the timer's BRK input. BKIN input is ORed with the other enabled BRK sources.

0: BKIN input disabled.

1: BKIN input enabled.

Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)

21.4.19 TIM16 input selection register (TIM16_TISEL)

Address offset: 0x68

Reset value: 0x0000

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TI1SEL[3:0]
rwrwrwrw

Bits 31:4 Reserved, must be kept at reset value.

Bits 3:0 TI1SEL[3:0] : selects TI1[0] to TI1[15] input

0000: TIMx_CH1 input

Others: Reserved

21.4.20 TIM16 register map

TIM16 registers are mapped as 16-bit addressable registers as described in the table below:

Table 66. TIM16 register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1ResResResResResResResResResResResResResResResResResResResResUIFREMAResCKD [1:0]ARPEResResResOPMURSUDISCEN
Reset value00000000
0x04TIMx_CR2ResResResResResResResResResResResResResResResResResResResResResOIS1NOIS1ResMMSCCDSCCUSResCCPC
Reset value0000000
0x08TIMx_SMCRResResResResResResResResResResTS[4:3]TS[4:3]ResResResSMS[3]ResResResResResResResMSMTS[2:0]ResSMS[2:0]
Reset value0000000
0x0CTIMx_DIERResResResResResResResResResResResResResResResResResTDEResResResResCC1DEUDEOIS1TIECOMIEResResResCC1IEUIE
Reset value00000000
0x10TIMx_SRResResResResResResResResResResResResResResResResResResResResResResCC1OFResBIFTIFCOMIFResResResCC1IFUIF
Reset value0000000
0x14TIMx_EGRResResResResResResResResResResResResResResResResResResResResResResResResBGTGCOMGResResResCC1GUG
Reset value00000
0x18TIMx_CCMR1 Output Compare modeResResResResResResResResResResResResResResResOC1M[3]ResResResResResResResResResOC1M [2:0]OC1PEOC1FECC1S [1:0]
Reset value0000000
TIMx_CCMR1 Input Capture modeResResResResResResResResResResResResResResResResResResResResResResResResIC1F[3:0]IC1 PSC [1:0]CC1S [1:0]
Reset value0000000
0x20TIMx_CCERResResResResResResResResResResResResResResResResResResResResResResResResResResResResCC1NPCC1NECC1PCC1E
Reset value00000
0x24TIMx_CNTUIFCPY or ResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value0
0x28TIMx_PSCResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value
0x2CTIMx_ARRResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResResRes
Reset value
Table 66. TIM16 register map and reset values (continued)
OffsetRegister313029282726252423222120191817161514131211109876543210
0x30TIMx_RCRResResResResResResResResResResResResResResResResResResResResResResResResREP[7:0]
Reset value00000000
0x34TIMx_CCR1ResResResResResResResResResResResResResResResResCCR1[15:0]
Reset value0000000000000000
0x44TIMx_BDTRResResResBKBIDResBKDSRMResResResResResResResResResResMOEAOEBKPBKEOSSROSSILOCK[1:0]DT[7:0]
Reset value000000000000000000
0x48TIMx_DCRResResResResResResResResResResResResResResResResResResResDBL[4:0]ResResResDBA[4:0]
Reset value0000000000
0x4CTIMx_DMARResResResResResResResResResResResResResResResResDMAB[15:0]
Reset value0000000000000000
0x50TIMx_ORResResResResResResResResResResResResResResResResResResResResResResResResResResResResResTI1_RMP[1:0]Res
Reset value00
0x60TIMx_AF1ResResResResResResResResResResResResResResResResResResResResResBKCMP1PBKINPResResResResResResResBKCMP1EBKINE
Reset value0001
0x68TIMx_TISELResResResResResResResResResResResResResResResResResResResResResResResResResResResResTI1SEL[3:0]
Reset value0000

Refer to Section 2.2.2: Memory map and register boundary addresses for the register boundary addresses.