27. Serial peripheral interface / inter-IC sound (SPI/I 2 S)

The STM32WL30xx/31xx/33xx embeds one SPI: SPI3.

The STM32WL31xx and STM32WL33xx embed two SPIs: SPI1, SPI3.

In the device, only SPI3 supports the I2S protocol in addition to SPI features. SPI1 does not support I2S.

27.1 Introduction

The SPI/I2S interface can be used to communicate with external devices using the SPI protocol or the I2S audio protocol. SPI or I2S mode is selectable by software. SPI Motorola mode is selected by default after a device reset.

The serial peripheral interface (SPI) protocol supports half-duplex, full-duplex and simplex synchronous, serial communication with external devices. The interface can be configured as master and in this case it provides the communication clock (SCK) to the external slave device. The interface is also capable of operating in multimaster configuration.

The Inter-IC sound (I2S) protocol is also a synchronous serial communication interface. It can operate in slave or master mode with full duplex and half-duplex communication. It can address four different audio standards including the Philips I2S standard, the MSB- and LSB-justified standards and the PCM standard.

27.2 SPI main features

27.3 I2S main features

27.4 SPI/I2S implementation

This manual describes the full set of features implemented in SPI1 (STM32WL33xx/31xx only), and SPI3.

The Table 94 describes the SPI/I2S implementation in the STM32WL30xx/31xx/33xx.

Table 94. SPI implementation(1)

SPI FeaturesSPI1SPI3
Hardware CRC calculationXX
Rx/Tx FIFOXX
NSS pulse modeXX
I2S mode-X
TI modeXX

1. X = supported.

27.5 SPI functional description

27.5.1 General description

The SPI allows synchronous, serial communication between the MCU and external devices. Application software can manage the communication by polling the status flag or using dedicated SPI interrupt. The main elements of SPI and their interactions are shown in the following block diagram Figure 230.

Figure 230. SPI block diagram

Figure 230. SPI block diagram. The diagram shows the internal architecture of the SPI peripheral. It includes an Address and data bus at the top. On the left, four I/O pins are shown: MOSI, MISO, SCK, and NSS. The MOSI and MISO pins are connected to a bidirectional shift register. The shift register is connected to an Rx FIFO (for reading) and a Tx FIFO (for writing). The shift register also connects to a Communication controller. The Communication controller is linked to a CRC controller and an NSS logic block. The NSS logic block is connected to the NSS pin and provides an Internal NSS signal. A Baud rate generator is connected to the SCK pin and provides a clock signal to the Communication controller. The Communication controller also receives control signals: RXONLY, CPOL, CPHA, and DS[0:3] from the Address and data bus, and BIDIOE from the NSS logic. It outputs CRCEN, CRCNEXT, and CRCL to the CRC controller. The Communication controller also receives a BR[2:0] signal from the Baud rate generator.
Figure 230. SPI block diagram. The diagram shows the internal architecture of the SPI peripheral. It includes an Address and data bus at the top. On the left, four I/O pins are shown: MOSI, MISO, SCK, and NSS. The MOSI and MISO pins are connected to a bidirectional shift register. The shift register is connected to an Rx FIFO (for reading) and a Tx FIFO (for writing). The shift register also connects to a Communication controller. The Communication controller is linked to a CRC controller and an NSS logic block. The NSS logic block is connected to the NSS pin and provides an Internal NSS signal. A Baud rate generator is connected to the SCK pin and provides a clock signal to the Communication controller. The Communication controller also receives control signals: RXONLY, CPOL, CPHA, and DS[0:3] from the Address and data bus, and BIDIOE from the NSS logic. It outputs CRCEN, CRCNEXT, and CRCL to the CRC controller. The Communication controller also receives a BR[2:0] signal from the Baud rate generator.

Four I/O pins are dedicated to SPI communication with external devices.

Note: If the SPI is in master mode and the internal pull-up/-down of the pad is used, the software must take care to activate the pull polarity (up or down) of the I/O to be coherent with the CPOL programming (pull-down if CPOL=0 and pull-up if CPOL=1).

See Section 27.5.4: Slave select (NSS) pin management for details.

The SPI bus allows the communication between one master device and one or more slave devices. The bus consists of at least two wires - one for the clock signal and the other for

synchronous data transfer. Other signals can be added depending on the data exchange between SPI nodes and their slave select signal management.

27.5.2 Communications between one master and one slave

The SPI allows the MCU to communicate using different configurations, depending on the device targeted and the application requirements. These configurations use 2 or 3 wires (with software NSS management) or 3 or 4 wires (with hardware NSS management). Communication is always initiated by the master.

Full-duplex communication

By default, the SPI is configured for full-duplex communication. In this configuration, the shift registers of the master and slave are linked using two unidirectional lines between the MOSI and the MISO pins. During SPI communication, data is shifted synchronously on the SCK clock edges provided by the master. The master transmits the data to be sent to the slave via the MOSI line and receives data from the slave via the MISO line. When the data frame transfer is complete (all the bits are shifted) the information between the master and slave is exchanged.

Figure 231. Full-duplex single master/ single slave application

Schematic diagram of a full-duplex single master/single slave SPI application. The Master side includes a shift register, an SPI clock generator, and pins MISO, MOSI, SCK, and NSS. The Slave side includes a shift register and pins MISO, MOSI, SCK, and NSS. The Master's MOSI is connected to the Slave's MOSI, and the Master's MISO is connected to the Slave's MISO. The SCK lines are connected together. The Master's NSS is connected to Vcc, and the Slave's NSS is connected to ground. Arrows indicate data flow: Master to Slave on MOSI, Slave to Master on MISO.
Schematic diagram of a full-duplex single master/single slave SPI application. The Master side includes a shift register, an SPI clock generator, and pins MISO, MOSI, SCK, and NSS. The Slave side includes a shift register and pins MISO, MOSI, SCK, and NSS. The Master's MOSI is connected to the Slave's MOSI, and the Master's MISO is connected to the Slave's MISO. The SCK lines are connected together. The Master's NSS is connected to Vcc, and the Slave's NSS is connected to ground. Arrows indicate data flow: Master to Slave on MOSI, Slave to Master on MISO.
  1. 1. The NSS pin is configured as an input in this case.

Half-duplex communication

The SPI can communicate in half-duplex mode by setting the BIDIMODE bit in the SPIx_CR1 register. In this configuration, one single cross connection line is used to link the shift registers of the master and slave together. During this communication, the data is synchronously shifted between the shift registers on the SCK clock edge in the transfer direction selected reciprocally by both master and slave with the BDIOE bit in their SPIx_CR1 registers. In this configuration, the master's MISO pin and the slave's MOSI pin are free for other application uses and act as GPIOs.

Figure 232. Half-duplex single master/ single slave application

Block diagram of a half-duplex single master/single slave SPI application. The Master side includes a shift register, an SPI clock generator, and pins MISO(2), MOSI, SCK, and NSS(1) connected to Vcc. The Slave side includes a shift register and pins MISO, MOSI(2), SCK, and NSS(1) connected to ground. The Master's MOSI is connected to the Slave's MOSI(2), and the Master's MISO(2) is connected to the Slave's MISO. The SCK lines are connected between the Master's clock generator and the Slave's shift register. The NSS pins are connected to Vcc and ground respectively.

MS19828V1

Block diagram of a half-duplex single master/single slave SPI application. The Master side includes a shift register, an SPI clock generator, and pins MISO(2), MOSI, SCK, and NSS(1) connected to Vcc. The Slave side includes a shift register and pins MISO, MOSI(2), SCK, and NSS(1) connected to ground. The Master's MOSI is connected to the Slave's MOSI(2), and the Master's MISO(2) is connected to the Slave's MISO. The SCK lines are connected between the Master's clock generator and the Slave's shift register. The NSS pins are connected to Vcc and ground respectively.
  1. 1. The NSS pin is configured as an input in this case.
  2. 2. In this configuration, the master's MISO pin and the slave's MOSI pin can be used as GPIOs.

Simplex communications

The SPI can communicate in simplex mode by setting the SPI in transmit-only or in receive-only using the RXONLY bit in the SPIx_CR2 register. In this configuration, only one line is used for the transfer between the shift registers of the master and slave. The remaining MISO and MOSI pins pair is not used for communication and can be used as standard GPIOs.

Figure 233. Simplex single master/single slave application (master in transmit-only/ slave in receive-only mode)

Block diagram of a simplex single master/single slave SPI application. The Master side includes a shift register and an SPI clock generator. The shift register is connected to the MOSI pin (labeled with a (2) indicating input capture) and its output is connected to the MISO pin. The SPI clock generator is connected to the SCK pin. The NSS pin is connected to Vcc, labeled with a (1) indicating it is an input. The Slave side includes a shift register connected to its MOSI pin and its output connected to its MISO pin. The Slave's SCK pin is connected to the Master's SCK. The Slave's NSS pin is connected to ground, labeled with a (1). Arrows indicate data flow: from Master shift register to Master MOSI, from Master MOSI to Slave MOSI, from Slave MISO to Slave shift register, and from Slave shift register to Slave MISO. The SCK line has arrows pointing to both shift registers. The MISO lines have arrows pointing away from the shift registers towards the pins.
Block diagram of a simplex single master/single slave SPI application. The Master side includes a shift register and an SPI clock generator. The shift register is connected to the MOSI pin (labeled with a (2) indicating input capture) and its output is connected to the MISO pin. The SPI clock generator is connected to the SCK pin. The NSS pin is connected to Vcc, labeled with a (1) indicating it is an input. The Slave side includes a shift register connected to its MOSI pin and its output connected to its MISO pin. The Slave's SCK pin is connected to the Master's SCK. The Slave's NSS pin is connected to ground, labeled with a (1). Arrows indicate data flow: from Master shift register to Master MOSI, from Master MOSI to Slave MOSI, from Slave MISO to Slave shift register, and from Slave shift register to Slave MISO. The SCK line has arrows pointing to both shift registers. The MISO lines have arrows pointing away from the shift registers towards the pins.
  1. 1. The NSS pin is configured as an input in this case.
  2. 2. The input information is captured in the shift register and must be ignored in standard transmit only mode (for example, OVF flag)
  3. 3. In this configuration, both the MISO pins can be used as GPIOs.

Note: Any simplex communication can be alternatively replaced by a variant of the half duplex communication with a constant setting of the transaction direction (bidirectional mode is enabled while BDIO bit is not changed).

27.5.3 Standard multi-slave communication

In a configuration with two or more independent slaves, the master uses GPIO pins to manage the chip select lines for each slave (see Figure 234). The master must select one of the slaves individually by pulling low the GPIO connected to the slave NSS input. When this is done, a standard master and dedicated slave communication is established.

Figure 234. Master and three independent slaves

Schematic diagram of a Master and three independent slaves connected via SPI/I2S. The Master contains a shift register, an SPI clock generator, and I/O pins 1, 2, and 3. The clock generator drives the SCK line for all slaves. The Master's shift register output goes to its MOSI and the slaves' MOSI lines. The slaves' MISO lines are connected together and feed back into the Master's shift register. Each slave has its own shift register and is selected by its NSS pin, which is connected to one of the Master's I/O pins (I/O 1, I/O 2, or I/O 3).

The diagram illustrates a Master device connected to three independent Slave devices. The Master includes a shift register, an SPI clock generator, and three I/O pins (I/O 1, I/O 2, and I/O 3). The SPI clock generator provides the SCK (Serial Clock) signal to all three slaves. The Master's shift register output is connected to its MOSI (Master Out Slave In) pin, which is also connected to the MOSI pins of all three slaves. The MISO (Master In Slave Out) pins of all three slaves are connected together and feed back into the Master's shift register. Each slave has its own shift register and is selected by its NSS (Slave Select) pin, which is connected to one of the Master's I/O pins (I/O 1, I/O 2, or I/O 3). The NSS pin for each slave is also connected to Vcc through a pull-up resistor.

Schematic diagram of a Master and three independent slaves connected via SPI/I2S. The Master contains a shift register, an SPI clock generator, and I/O pins 1, 2, and 3. The clock generator drives the SCK line for all slaves. The Master's shift register output goes to its MOSI and the slaves' MOSI lines. The slaves' MISO lines are connected together and feed back into the Master's shift register. Each slave has its own shift register and is selected by its NSS pin, which is connected to one of the Master's I/O pins (I/O 1, I/O 2, or I/O 3).
  1. 1. As MISO pins of the slaves are connected together, all slaves must have the GPIO configuration of their MISO pin set as alternate function open-drain (see Table 8: GPIO alternate options AF0 - AF3 and Table 9: GPIO alternate options AF4 - AF6).

27.5.4 Slave select (NSS) pin management

In slave mode, the NSS works as a standard “chip select” input and lets the slave communicate with the master. In master mode, NSS can be used either as output or input. As an input it can prevent multimaster bus collision, and as an output it can drive a slave select signal of a single slave.

Hardware or software slave select management can be set using the SSM bit in the SPIx_CR1 register:

Figure 235. Hardware/software slave select management

Block diagram of Hardware/software slave select management. The diagram shows the NSS pin connected to a GPIO logic block, which is part of the NSS external logic. The NSS external logic also includes a multiplexer (MUX) with inputs 1 and 0. Input 1 is connected to the SSI control bit, and input 0 is connected to the NSS Output Control block. The MUX output is the NSS Input. The NSS Output Control block is part of the NSS internal logic and is controlled by the SSOE control bit. The NSS Output Control block also receives the NSS Input signal. The NSS Output Control block outputs the NSS Output signal, which is used in Master mode & NSS HW management only. A table in the diagram shows the status of the NSS Input in Master and Slave modes.
NSS Inp.Master modeSlave mode
VddOKNon active
VssConflictActive

aiv14746e

Block diagram of Hardware/software slave select management. The diagram shows the NSS pin connected to a GPIO logic block, which is part of the NSS external logic. The NSS external logic also includes a multiplexer (MUX) with inputs 1 and 0. Input 1 is connected to the SSI control bit, and input 0 is connected to the NSS Output Control block. The MUX output is the NSS Input. The NSS Output Control block is part of the NSS internal logic and is controlled by the SSOE control bit. The NSS Output Control block also receives the NSS Input signal. The NSS Output Control block outputs the NSS Output signal, which is used in Master mode & NSS HW management only. A table in the diagram shows the status of the NSS Input in Master and Slave modes.

27.5.5 Communication formats

During SPI communication, receive and transmit operations are performed simultaneously. The serial clock (SCK) synchronizes the shifting and sampling of the information on the data lines. The communication format depends on the clock phase, the clock polarity and the data frame format. To be able to communicate together, the master and slaves devices must follow the same communication format.

Clock phase and polarity controls

Four possible timing relationships may be chosen by software, using the CPOL and CPHA bits in the SPIx_CR1 register. The CPOL (clock polarity) bit controls the idle state value of the clock when no data is being transferred. This bit affects both master and slave modes. If CPOL is reset, the SCK pin has a low-level idle state. If CPOL is set, the SCK pin has a high-level idle state.

If the CPHA bit is set, the second edge on the SCK pin captures the first data bit transacted (falling edge if the CPOL bit is reset, rising edge if the CPOL bit is set). Data are latched on each occurrence of this clock transition type. If the CPHA bit is reset, the first edge on the SCK pin captures the first data bit transacted (falling edge if the CPOL bit is set, rising edge if the CPOL bit is reset). Data are latched on each occurrence of this clock transition type.

The combination of CPOL (clock polarity) and CPHA (clock phase) bits selects the data capture clock edge.

Figure 236, shows an SPI full-duplex transfer with the four combinations of the CPHA and CPOL bits.

Note: Prior to changing the CPOL/CPHA bits the SPI must be disabled by resetting the SPE bit. The idle state of SCK must correspond to the polarity selected in the SPIx_CR1 register (by pulling up SCK if CPOL=1 or pulling down SCK if CPOL=0).

Figure 236. Data clock timing diagram

Timing diagram for SPI data clock showing CPHA=1 and CPHA=0 modes. It includes waveforms for CPOL=1, CPOL=0, MOSI, MISO, NSS (to slave), and Capture strobe. Data bits are labeled from MSBit to LSBit.

The diagram illustrates the data clock timing for SPI in two modes: CPHA = 1 and CPHA = 0. It shows the relationship between the clock polarity (CPOL), clock phase (CPHA), and data transfer on the MOSI and MISO lines. The NSS (to slave) signal is shown as a low-active chip select, and the Capture strobe indicates when data is sampled.

CPHA = 1 Section:
- CPOL = 1: Clock starts at high. Data is sampled on the rising edge of the clock.
- CPOL = 0: Clock starts at low. Data is sampled on the rising edge of the clock.
- MOSI: Data is shifted out starting from the MSBit on the first rising edge.
- MISO: Data is shifted in starting from the MSBit on the first rising edge.
- NSS (to slave): Active low signal that enables the slave.
- Capture strobe: Pulses on the rising edges of the clock.

CPHA = 0 Section:
- CPOL = 1: Clock starts at high. Data is sampled on the falling edge of the clock.
- CPOL = 0: Clock starts at low. Data is sampled on the falling edge of the clock.
- MOSI: Data is shifted out starting from the MSBit on the first falling edge.
- MISO: Data is shifted in starting from the MSBit on the first falling edge.
- NSS (to slave): Active low signal that enables the slave.
- Capture strobe: Pulses on the falling edges of the clock.

ai17154d

Timing diagram for SPI data clock showing CPHA=1 and CPHA=0 modes. It includes waveforms for CPOL=1, CPOL=0, MOSI, MISO, NSS (to slave), and Capture strobe. Data bits are labeled from MSBit to LSBit.

1. The order of data bits depends on LSBFIRST bit setting.

Data frame format

The SPI shift register can be set up to shift out MSB-first or LSB-first, depending on the value of the LSBFIRST bit. The data frame size is chosen by using the DS bits. It can be set from 4-bit up to 16-bit length and the setting applies for both transmission and reception. Whatever the selected data frame size, read access to the FIFO must be aligned with the FRXTH level. When the SPIx_DR register is accessed, data frames are always right-aligned into either a byte (if the data fits into a byte) or a half-word (see Figure 237). During communication, only bits within the data frame are clocked and transferred.

Figure 237. Data alignment when data length is not equal to 8-bit or 16-bit Figure 237: Data alignment when data length is not equal to 8-bit or 16-bit. The diagram shows four bit-level diagrams for TX and RX data frames. For DS <= 8 bits (example DS = 5 bit), the TX frame has bits 7-5 labeled 'XXX' and bits 4-0 labeled 'Data frame'. The RX frame has bits 7-5 labeled '000' and bits 4-0 labeled 'Data frame'. For DS > 8 bits (example DS = 14 bit), the TX frame has bits 15-14 labeled 'XX' and bits 13-0 labeled 'Data frame'. The RX frame has bits 15-14 labeled '00' and bits 13-0 labeled 'Data frame'. All frames are right-aligned on the byte boundary (bit 0).

DS ≤ 8 bits: data is right-aligned on byte
Example: DS = 5 bit

DS > 8 bits: data is right-aligned on 16 bit
Example: DS = 14 bit

MS19589V2

Figure 237: Data alignment when data length is not equal to 8-bit or 16-bit. The diagram shows four bit-level diagrams for TX and RX data frames. For DS <= 8 bits (example DS = 5 bit), the TX frame has bits 7-5 labeled 'XXX' and bits 4-0 labeled 'Data frame'. The RX frame has bits 7-5 labeled '000' and bits 4-0 labeled 'Data frame'. For DS > 8 bits (example DS = 14 bit), the TX frame has bits 15-14 labeled 'XX' and bits 13-0 labeled 'Data frame'. The RX frame has bits 15-14 labeled '00' and bits 13-0 labeled 'Data frame'. All frames are right-aligned on the byte boundary (bit 0).

Note: The minimum data length is 4 bits. If a data length of less than 4 bits is selected, it is forced to an 8-bit data frame size.

27.5.6 Configuration of SPI

The configuration procedure is almost the same for master and slave. For specific mode setups, follow the dedicated chapters. When a standard communication is to be initialized, perform these steps:

  1. 1. Write proper GPIO registers: Configure GPIO for MOSI, MISO and SCK pins.
  2. 2. Write to the SPI_CR1 register:
    1. a) Configure the serial clock baud rate using the BR[2:0] bits (Note 4).
    2. b) Configure the CPOL and CPHA bits combination to define one of the four relationships between the data transfer and the serial clock (CPHA must be cleared in NSSP mode). (Note 2).
    3. c) Select simplex or half-duplex mode by configuring RXONLY or BIDIMODE and BIDIOE (RXONLY and BIDIMODE can't be set at the same time).
    4. d) Configure the LSBFIRST bit to define the frame format (Note 2).
    5. e) Configure the CRCL and CRCEN bits if CRC is needed (while SCK clock signal is at idle state).
    6. f) Configure SSM and SSI (Notes 2,3).
    7. g) Configure the MSTR bit (in multimaster NSS configuration, avoid conflict state on NSS if master is configured to prevent MODF error).
  3. 3. Write to SPI_CR2 register:
    1. a) Configure the DS[3:0] bits to select the data length for the transfer.
    2. b) Configure SSOE (Note: 1,2,3).
    3. c) Set the FRF bit if the TI protocol is required (keep NSSP bit cleared in TI mode).
    4. d) Set the NSSP bit if the NSS pulse mode between two data units is required (keep CPHA and TI bits cleared in NSSP mode).
    5. e) Configure the FRXTH bit. The RXFIFO threshold must be aligned to the read access size for the SPIx_DR register.
    6. f) Initialize LDMA_TX and LDMA_RX bits if DMA is used in packed mode.
  4. 4. Write to SPI_CRCPR register: Configure the CRC polynomial if needed.
  5. 5. Write proper DMA registers: Configure DMA streams dedicated for SPI Tx and Rx in DMA registers if the DMA streams are used.
  1. Note:
  2. 1 Step is not required in slave mode.
  3. 2 Step is not required in TI mode.
  4. 3 Step is not required in NSSP mode.
  5. 4 The step is not required in slave mode except slave working at TI mode(1)

27.5.7 Procedure for enabling SPI

It is recommended to enable the SPI slave before the master sends the clock. If not, undesired data transmission might occur. The data register of the slave must already contain data to be sent before starting communication with the master (either on the first edge of the communication clock, or before the end of the ongoing communication if the clock signal is continuous). The SCK signal must be settled at an idle state level corresponding to the selected polarity before the SPI slave is enabled.

The master at full duplex (or in any transmit-only mode) starts to communicate when the SPI is enabled and TXFIFO is not empty, or with the next write to TXFIFO.

In any master receive only mode (RXONLY=1 or BIDIMODE=1 & BIDIOE=0), master starts to communicate and the clock starts running immediately after SPI is enabled.

For handling DMA, follow the dedicated chapter.

27.5.8 Data transmission and reception procedures

RXFIFO and TXFIFO

All SPI data transactions pass through the 32-bit embedded FIFOs. This enables the SPI to work in a continuous flow, and prevents overruns when the data frame size is short. Each direction has its own FIFO called TXFIFO and RXFIFO. These FIFOs are used in all SPI modes except for receiver-only mode (slave or master) with CRC calculation enabled (see Section 27.5.13: CRC calculation).

The handling of FIFOs depends on the data exchange mode (duplex, simplex), data frame format (number of bits in the frame), access size performed on the FIFO data registers (8-bit or 16-bit), and whether or not data packing is used when accessing the FIFOs (see Section 27.5.12: TI mode).

A read access to the SPIx_DR register returns the oldest value stored in RXFIFO that has not been read yet. A write access to the SPIx_DR stores the written data in the TXFIFO at the end of a send queue. The read access must be always aligned with the RXFIFO threshold configured by the FRXTH bit in SPIx_CR2 register. FTLVL[1:0] and FRLVL[1:0] bits indicate the current occupancy level of both FIFOs.

A read access to the SPIx_DR register must be managed by the RXNE event. This event is triggered when data is stored in RXFIFO and the threshold (defined by FRXTH bit) is reached. When RXNE is cleared, RXFIFO is considered to be empty. In a similar way, write access of a data frame to be transmitted is managed by the TXE event. This event is triggered when the TXFIFO level is less than or equal to half of its capacity. Otherwise TXE is cleared and the TXFIFO is considered as full. In this way, RXFIFO can store up to four data frames, whereas TXFIFO can only store up to three when the data frame format is not greater than 8 bits. This difference prevents possible corruption of 3x 8-bit data frames already stored in the TXFIFO when software tries to write more data in 16-bit mode into TXFIFO. Both TXE and RXNE events can be polled or handled by interrupts. See Figure 239 through Figure 242.

Another way to manage the data exchange is to use DMA (see Section 10: DMA controller (DMA)).

If the next data is received when the RXFIFO is full, an overrun event occurs (see description of OVR flag at Section 27.5.10: SPI error flags). An overrun event can be polled or handled by an interrupt.

The BSY bit being set indicates ongoing transaction of a current data frame. When the clock signal runs continuously, the BSY flag stays set between data frames at master but becomes low for a minimum duration of one SPI clock at slave between each data frame transfer.

Sequence handling

A few data frames can be passed at single sequence to complete a message. When transmission is enabled, a sequence begins and continues while any data is present in the TXFIFO of the master. The clock signal is provided continuously by the master until TXFIFO becomes empty, then it stops waiting for additional data.

In receive-only modes, half duplex (BIDIMODE=1, BIDIOE=0) or simplex (BIDIMODE=0, RXONLY=1) the master starts the sequence immediately when both SPI is enabled and receive-only mode is activated. The clock signal is provided by the master and it does not stop until either SPI or receive-only mode is disabled by the master. The master receives data frames continuously up to this moment.

While the master can provide all the transactions in continuous mode (SCK signal is continuous) it has to respect slave capability to handle data flow and its content at anytime. When necessary, the master must slow down the communication and provide either a slower clock or separate frames or data sessions with sufficient delays. Be aware there is no underflow error signal for master or slave in SPI mode, and data from the slave is always transacted and processed by the master even if the slave could not prepare it correctly in time. It is preferable for the slave to use DMA, especially when data frames are shorter and bus rate is high.

Each sequence must be encased by the NSS pulse in parallel with the multislave system to select just one of the slaves for communication. In a single slave system it is not necessary to control the slave with NSS, but it is often better to provide the pulse here too, to synchronize the slave with the beginning of each data sequence. NSS can be managed by both software and hardware (see Section 27.5.4: Slave select (NSS) pin management).

When the BSY bit is set it signifies an ongoing data frame transaction. When the dedicated frame transaction is finished, the RXNE flag is raised. The last bit is just sampled and the complete data frame is stored in the RXFIFO.

Procedure for disabling the SPI

When SPI is disabled, it is mandatory to follow the disable procedures described in this paragraph. It is important to do this before the system enters a low-power mode when the peripheral clock is stopped. Ongoing transactions can be corrupted in this case. In some modes the disable procedure is the only way to stop continuous communication running.

Master in full duplex or transmit only mode can finish any transaction when it stops providing data for transmission. In this case, the clock stops after the last data transaction. Special care must be taken in packing mode when an odd number of data frames are transacted to prevent some dummy byte exchange (refer to Data packing section). Before the SPI is disabled in these modes, the user must follow standard disable procedure. When the SPI is

disabled at the master transmitter while a frame transaction is ongoing or next data frame is stored in TXFIFO, the SPI behavior is not guaranteed.

When the master is in any receive only mode, the only way to stop the continuous clock is to disable the peripheral by SPE=0. This must occur in specific time window within last data frame transaction just between the sampling time of its first bit and before its last bit transfer starts (in order to receive a complete number of expected data frames and to prevent any additional "dummy" data reading after the last valid data frame). Specific procedure must be followed when disabling SPI in this mode.

Data received but not read remains stored in RXFIFO when the SPI is disabled, and must be processed the next time the SPI is enabled, before starting a new sequence. To prevent having unread data, ensure that RXFIFO is empty when disabling the SPI, by using the correct disabling procedure, or by initializing all the SPI registers with a software reset via the control of a specific register dedicated to peripheral reset (see the SPIRST bits in the RCC_APBIRSTR registers).

Standard disable procedure is based on pulling BSY status together with FTLVL[1:0] to check if a transmission session is fully completed. This check can be done in specific cases, too, when it is necessary to identify the end of ongoing transactions, for example:

The correct disable procedure is (except when receive only mode is used):

  1. 1. Wait until FTLVL[1:0] = 00 (no more data to transmit).
  2. 2. Wait until BSY=0 (the last data frame is processed).
  3. 3. Disable the SPI (SPE=0).
  4. 4. Read data until FRLVL[1:0] = 00 (read all the received data).

The correct disable procedure for certain receive only modes is:

  1. 1. Interrupt the receive flow by disabling SPI (SPE=0) in the specific time window while the last data frame is ongoing.
  2. 2. Wait until BSY=0 (the last data frame is processed).
  3. 3. Read data until FRLVL[1:0] = 00 (read all the received data).

Note: If packing mode is used and an odd number of data frames with a format less than or equal to 8 bits (fitting into one byte) has to be received, FRXTH must be set when FRLVL[1:0] = 01, in order to generate the RXNE event to read the last odd data frame and to keep good FIFO pointer alignment.

Data packing

When the data frame size fits into one byte (less than or equal to 8 bits), data packing is used automatically when any read or write 16-bit access is performed on the SPIx_DR register. The double data frame pattern is handled in parallel in this case. At first, the SPI operates using the pattern stored in the LSB of the accessed word, then with the other half stored in the MSB. Figure 238 provides an example of data packing mode sequence handling. Two data frames are sent after the single 16-bit access the SPIx_DR register of the transmitter. This sequence can generate just one RXNE event in the receiver if the RXFIFO threshold is set to 16 bits (FRXTH=0). The receiver then has to access both data frames by a single 16-bit read of SPIx_DR as a response to this single RXNE event. The

RxFIFO threshold setting and the following read access must be always kept aligned at the receiver side, as data can be lost if it is not in line.

A specific problem appears if an odd number of such “fit into one byte” data frames must be handled. On the transmitter side, writing the last data frame of any odd sequence with an 8-bit access to SPIx_DR is enough. The receiver has to change the Rx_FIFO threshold level for the last data frame received in the odd sequence of frames in order to generate the RXNE event.

Figure 238. Packing data in FIFO for transmission and reception

Figure 238: Packing data in FIFO for transmission and reception. The diagram shows the data flow between SPIx_DR, TXFIFO, SPI fsm & shift, and RXFIFO. It includes waveforms for NSS, SCK, and MOSI. Text annotations specify 16-bit access conditions for writing and reading the data register.

The diagram illustrates the data packing and unpacking process in the SPI FIFO. On the transmitter side, data from SPIx_DR (containing 0x04 and 0x0A) is packed into TXFIFO (containing 0x0A and 0x04) and then shifted by the SPI fsm & shift block. On the receiver side, data is shifted by the SPI fsm & shift block and unpacked into RXFIFO (containing 0x0A and 0x04) before being written to SPIx_DR. Waveforms for NSS, SCK, and MOSI are shown at the top. Text annotations specify 16-bit access conditions for writing and reading the data register.

16-bit access when write to data register
SPI_DR= 0x040A when TxE=1

16-bit access when read from data register
SPI_DR= 0x040A when RxNE=1

MS19590V1

Figure 238: Packing data in FIFO for transmission and reception. The diagram shows the data flow between SPIx_DR, TXFIFO, SPI fsm & shift, and RXFIFO. It includes waveforms for NSS, SCK, and MOSI. Text annotations specify 16-bit access conditions for writing and reading the data register.

Communication using DMA (direct memory addressing)

To operate at its maximum speed and to facilitate the data register read/write process required to avoid overrun, the SPI features a DMA capability, which implements a simple request/acknowledge protocol.

A DMA access is requested when the TXE or RXNE enable bit in the SPIx_CR2 register is set. Separate requests must be issued to the Tx and Rx buffers.

See Figure 239 through Figure 242.

When the SPI is used only to transmit data, it is possible to enable only the SPI Tx DMA channel. In this case, the OVR flag is set because the data received is not read. When the SPI is used only to receive data, it is possible to enable only the SPI Rx DMA channel.

In transmission mode, when the DMA has written all the data to be transmitted (the TCIF flag is set in the DMA_ISR register), the BSY flag can be monitored to ensure that the SPI communication is complete. This is required to avoid corrupting the last transmission before disabling the SPI or entering the Stop mode. The software must first wait until FTLVL[1:0]=00 and then until BSY=0.

When starting communication using DMA, to prevent DMA channel management raising error events, these steps must be followed in order:

  1. 1. Enable DMA Rx buffer in the RXDMAEN bit in the SPI_CR2 register, if DMA Rx is used.
  2. 2. Enable DMA streams for Tx and Rx in DMA registers, if the streams are used.
  3. 3. Enable DMA Tx buffer in the TXDMAEN bit in the SPI_CR2 register, if DMA Tx is used.
  4. 4. Enable the SPI by setting the SPE bit.

To close communication it is mandatory to follow these steps in order:

  1. 1. Disable DMA streams for Tx and Rx in the DMA registers, if the streams are used.
  2. 2. Disable the SPI by following the SPI disable procedure.
  3. 3. Disable DMA Tx and Rx buffers by clearing the TXDMAEN and RXDMAEN bits in the SPI_CR2 register, if DMA Tx and/or DMA Rx are used.

Packing with DMA

If the transfers are managed by DMA (TXDMAEN and RXDMAEN set in the SPIx_CR2 register) packing mode is enabled/disabled automatically depending on the PSIZE value configured for SPI TX and the SPI RX DMA channel. If the DMA channel PSIZE value is equal to 16-bit and SPI data size is less than or equal to 8-bit, then packing mode is enabled. The DMA then automatically manages the write operations to the SPIx_DR register.

If data packing mode is used and the number of data to transfer is not a multiple of two, the LDMA_TX/LDMA_RX bits must be set. The SPI then considers only one data for the transmission or reception to serve the last DMA transfer (for more details refer to Data packing.)

Communication diagrams

Some typical timing schemes are explained in this section. These schemes are valid no matter if the SPI events are handled by pulling, interrupts or DMA. For simplicity, the LSBFIRST=0, CPOL=0 and CPHA=1 setting is used as a common assumption here. No complete configuration of DMA streams is provided.

The following numbered notes are common for Figure 239 through Figure 242.

  1. 1. The slave starts to control MISO line as NSS is active and SPI is enabled, and is disconnected from the line when one of them is released. Sufficient time must be provided for the slave to prepare data dedicated to the master in advance before its transaction starts.
    At the master, the SPI peripheral takes control at MOSI and SCK signals (occasionally at NSS signal as well) only if SPI is enabled. If SPI is disabled the SPI peripheral is disconnected from GPIO logic, so the levels at these lines depends on GPIO setting exclusively.
  2. 2. At the master, BSY stays active between frames if the communication (clock signal) is continuous. At the slave, BSY signal always goes down for at least one clock cycle between data frames.
  3. 3. The TXE signal is cleared only if TXFIFO is full.
  4. 4. The DMA arbitration process starts just after the TXDMAEN bit is set. The TXE interrupt is generated just after the TXEIE is set. As the TXE signal is at an active level, data transfers to TxFIFO start, until TxFIFO becomes full or the DMA transfer completes.
  5. 5. If all the data to be sent can fit into TxFIFO, the DMA Tx TCIF flag can be raised even before communication on the SPI bus starts. This flag always rises before the SPI transaction is completed.
  6. 6. The CRC value for a package is calculated continuously frame by frame in the SPIx_TxCRCR and SPIx_RxCRCR registers. The CRC information is processed after the entire data package has completed, either automatically by DMA (Tx channel must be set to the number of data frames to be processed) or by SW (the user must handle CRCNEXT bit during the last data frame processing).
    While the CRC value calculated in SPIx_TxCRCR is simply sent out by transmitter, received CRC information is loaded into RxFIFO and then compared with the SPIx_RxCRCR register content (CRC error flag can be raised here if any difference). This is why the user must take care to flush this information from the FIFO, either by software reading out all the stored content of RxFIFO, or by DMA when the proper number of data frames is preset for Rx channel (number of data frames + number of CRC frames) (see the settings at the example assumption).
  7. 7. In data packed mode, TxE and RxNE events are paired and each read/write access to the FIFO is 16 bits wide until the number of data frames are even. If the TxFIFO is \(\frac{3}{4}\) full FTLVL status stays at FIFO full level. That is why the last odd data frame cannot be stored before the TxFIFO becomes \(\frac{1}{2}\) full. This frame is stored into TxFIFO with an 8-bit access either by software or automatically by DMA when LDMA_TX control is set.
  8. 8. To receive the last odd data frame in packed mode, the Rx threshold must be changed to 8-bit when the last data frame is processed, either by software setting FRXTH=1 or automatically by a DMA internal signal when LDMA_RX is set.

Figure 239. Master full duplex communication

Timing diagram for Master full duplex communication showing NSS, SCK, BSY, MOSI, SPE, TXE, FTLVL, MISO, RXNE, FRLVL, DMA Tx TICF, and DMA Rx TICF signals. It details the sequence of three data frames (DTx1, DTx2, DTx3) and their corresponding reception (DRx1, DRx2, DRx3) with MSB/LSB markers and DMA control blocks.

The diagram illustrates the timing for master full duplex communication. It shows the following signals and their behavior:

Annotations in the diagram include:

MSv19266V1

Timing diagram for Master full duplex communication showing NSS, SCK, BSY, MOSI, SPE, TXE, FTLVL, MISO, RXNE, FRLVL, DMA Tx TICF, and DMA Rx TICF signals. It details the sequence of three data frames (DTx1, DTx2, DTx3) and their corresponding reception (DRx1, DRx2, DRx3) with MSB/LSB markers and DMA control blocks.

Assumptions for master full duplex communication example:

If DMA is used:

See also Communication diagrams for details about common assumptions and notes.

Figure 240. Slave full duplex communication

Timing diagram for slave full duplex communication showing NSS, SCK, BSY, MISO, SPE, TXE, FTLVL, MOSI, RXNE, and FRLVL signals. It details the sequence of three data transactions (DTx1, DTx2, DTx3) and their corresponding reception (DRx1, DRx2, DRx3) with MSB and LSB markers. Control signals like DMA Tx TICF and DMA Rx TICF are also shown.

The diagram illustrates the timing for slave full duplex communication. It shows the following signals and events:

Annotations: (1) marks the start of transmission; (2) marks the BSY high period; (3) marks TXE low periods; (4) marks the start of DMA enable; (5) marks the DMA Tx TICF assertion.

Timing diagram for slave full duplex communication showing NSS, SCK, BSY, MISO, SPE, TXE, FTLVL, MOSI, RXNE, and FRLVL signals. It details the sequence of three data transactions (DTx1, DTx2, DTx3) and their corresponding reception (DRx1, DRx2, DRx3) with MSB and LSB markers. Control signals like DMA Tx TICF and DMA Rx TICF are also shown.

MSv32123V1

Assumptions for slave full duplex communication example:

If DMA is used:

See also Communication diagrams for details about common assumptions and notes.

Figure 241. Master full duplex communication with CRC

Timing diagram of master full duplex communication with CRC showing NSS, SCK, BSY, MOSI, SPE, TXE, FTLVL, MISO, RXNE, FRLVL, DMA Tx TICF, and DMA Rx TICF signals.

The diagram illustrates the timing for master full duplex communication with CRC. It includes the following signals and data flows:

Control banners indicate:

MSv32124V1

Timing diagram of master full duplex communication with CRC showing NSS, SCK, BSY, MOSI, SPE, TXE, FTLVL, MISO, RXNE, FRLVL, DMA Tx TICF, and DMA Rx TICF signals.

Assumptions for master full duplex communication with CRC example:

If DMA is used:

See also Communication diagrams for details about common assumptions and notes.

Figure 242. Master full duplex communication in packed mode

Timing diagram for Master full duplex communication in packed mode. The diagram shows the following signals: NSS (active low), SCK (clock), BSY (busy), MOSI (master out slave in), SPE (SPI enable), TXE (transmit data register empty), FTLVL (FIFO threshold level), MISO (master in slave out), RXNE (receive data register not empty), and FRLVL (FIFO level). The diagram illustrates the sequence of events for three transmit frames (DTx1-2, DTx3-4, DTx5) and three receive frames (DRx1-2, DRx3-4, DRx5). Each frame consists of 5 data bits. The diagram shows the enable of Tx/Rx DMA or interrupts, DMA or software control at Tx events, and DMA or software control at Rx events. The diagram also shows the DMA Tx TICF and DMA Rx TICF signals. The diagram is labeled MSv32125V1.

The diagram illustrates the timing and control signals for master full duplex communication in packed mode. It shows the following signals and events:

Timing diagram for Master full duplex communication in packed mode. The diagram shows the following signals: NSS (active low), SCK (clock), BSY (busy), MOSI (master out slave in), SPE (SPI enable), TXE (transmit data register empty), FTLVL (FIFO threshold level), MISO (master in slave out), RXNE (receive data register not empty), and FRLVL (FIFO level). The diagram illustrates the sequence of events for three transmit frames (DTx1-2, DTx3-4, DTx5) and three receive frames (DRx1-2, DRx3-4, DRx5). Each frame consists of 5 data bits. The diagram shows the enable of Tx/Rx DMA or interrupts, DMA or software control at Tx events, and DMA or software control at Rx events. The diagram also shows the DMA Tx TICF and DMA Rx TICF signals. The diagram is labeled MSv32125V1.

Assumptions for master full duplex communication in packed mode example:

If DMA is used:

See also Communication diagrams for details about common assumptions and notes.

27.5.9 SPI status flags

Three status flags are provided for the application to completely monitor the state of the SPI bus.

Tx buffer empty flag (TXE)

The TXE flag is set when transmission TXFIFO has enough space to store data to send. TXE flag is linked to the TXFIFO level. The flag goes high and stays high until the TXFIFO level is lower or equal to 1/2 of the FIFO depth. An interrupt can be generated if the TXEIE bit in the SPIx_CR2 register is set. The bit is cleared automatically when the TXFIFO level becomes greater than 1/2.

Rx buffer not empty (RXNE)

The RXNE flag is set depending on the FRXTH bit value in the SPIx_CR2 register:

An interrupt can be generated if the RXNEIE bit in the SPIx_CR2 register is set.

The RXNE is cleared by hardware automatically when the above conditions are no longer true.

Busy flag (BSY)

The BSY flag is set and cleared by hardware (writing to this flag has no effect).

When BSY is set, it indicates that a data transfer is in progress on the SPI (the SPI bus is busy).

The BSY flag can be used in certain modes to detect the end of a transfer so that the software can disable the SPI or its peripheral clock before entering a low-power mode which does not provide a clock for the peripheral. This avoids corrupting the last transfer.

The BSY flag is also useful for preventing write collisions in a multimaster system.

The BSY flag is cleared under any one of the following conditions:

Note: When the next transmission can be handled immediately by the master (e.g. if the master is in Receive-only mode or its Transmit FIFO is not empty), communication is continuous and the BSY flag remains set to '1' between transfers on the master side. Although this is not the case with a slave, it is recommended to use always the TXE and RXNE flags (instead of the BSY flags) to handle data transmission or reception operations.

27.5.10 SPI error flags

An SPI interrupt is generated if one of the following error flags is set and interrupt is enabled by setting the ERRIE bit.

Overrun flag (OVR)

An overrun condition occurs when data is received by a master or slave and the RXFIFO has not enough space to store this received data. This can happen if the software or the DMA did not have enough time to read the previously received data (stored in the RXFIFO) or when space for data storage is limited e.g. the RXFIFO is not available when CRC is enabled in receive only mode so in this case the reception buffer is limited into a single data frame buffer (see Section 27.5.13: CRC calculation).

When an overrun condition occurs, the newly received value does not overwrite the previous one in the RXFIFO. The newly received value is discarded and all data transmitted subsequently is lost. Clearing the OVR bit is done by a read access to the SPI_DR register followed by a read access to the SPI_SR register.

Mode fault (MODF)

Mode fault occurs when the master device has its internal NSS signal (NSS pin in NSS hardware mode, or SSI bit in NSS software mode) pulled low. This automatically sets the MODF bit. Master mode fault affects the SPI interface in the following ways:

Use the following software sequence to clear the MODF bit:

  1. 1. Make a read or write access to the SPIx_SR register while the MODF bit is set.
  2. 2. Then write to the SPIx_CR1 register.

To avoid any multiple slave conflicts in a system comprising several MCUs, the NSS pin must be pulled high during the MODF bit clearing sequence. The SPE and MSTR bits can be restored to their original state after this clearing sequence. As a security, hardware does not allow the SPE and MSTR bits to be set while the MODF bit is set. In a slave device the MODF bit cannot be set except as the result of a previous multimaster conflict.

CRC error (CRCERR)

This flag is used to verify the validity of the value received when the CRCEN bit in the SPIx_CR1 register is set. The CRCERR flag in the SPIx_SR register is set if the value received in the shift register does not match the receiver SPIx_RXCRCR value. The flag is cleared by the software.

TI mode frame format error (FRE)

A TI mode frame format error is detected when an NSS pulse occurs during an ongoing communication when the SPI is operating in slave mode and configured to conform to the TI mode protocol. When this error occurs, the FRE flag is set in the SPIx_SR register. The SPI is not disabled when an error occurs, the NSS pulse is ignored, and the SPI waits for the next NSS pulse before starting a new transfer. The data may be corrupted since the error detection may result in the loss of two data bytes.

The FRE flag is cleared when SPIx_SR register is read. If the ERRIE bit is set, an interrupt is generated on the NSS error detection. In this case, the SPI should be disabled because data consistency is no longer guaranteed and communications should be reinitiated by the master when the slave SPI is enabled again.

27.5.11 NSS pulse mode

This mode is activated by the NSSP bit in the SPIx_CR2 register and it takes effect only if the SPI interface is configured as Motorola SPI master (FRF=0) with capture on the first edge (SPIx_CR1 CPHA = 0, CPOL setting is ignored). When activated, an NSS pulse is generated between two consecutive data frame transfers when NSS stays at high level for the duration of one clock period at least. This mode allows the slave to latch data. NSSP pulse mode is designed for applications with a single master-slave pair.

Figure 243 illustrates NSS pin management when NSSP pulse mode is enabled.

Figure 243. NSSP pulse generation in Motorola SPI master mode

Timing diagram for NSSP pulse generation in Motorola SPI master mode. The diagram shows four signals: NSS output, SCK output, MOSI output, and MISO input. The title is 'Master continuous transfer (CPOL = 1; CPHA = 0; NSSP = 1)'. The NSS output signal is high most of the time, with a low pulse between data transfers. The SCK output is a square wave. The MOSI output shows data frames (MSB to LSB) being shifted out. The MISO input shows data frames (MSB to LSB) being shifted in, with 'DONTCARE' periods. Sampling points are indicated by vertical dashed lines labeled 'sampling'. Timing parameters t_SCK are shown between clock edges. Data frame lengths are indicated as '4-bits to 16-bits'. The diagram is labeled MS19838V1 in the bottom right corner.
Timing diagram for NSSP pulse generation in Motorola SPI master mode. The diagram shows four signals: NSS output, SCK output, MOSI output, and MISO input. The title is 'Master continuous transfer (CPOL = 1; CPHA = 0; NSSP = 1)'. The NSS output signal is high most of the time, with a low pulse between data transfers. The SCK output is a square wave. The MOSI output shows data frames (MSB to LSB) being shifted out. The MISO input shows data frames (MSB to LSB) being shifted in, with 'DONTCARE' periods. Sampling points are indicated by vertical dashed lines labeled 'sampling'. Timing parameters t_SCK are shown between clock edges. Data frame lengths are indicated as '4-bits to 16-bits'. The diagram is labeled MS19838V1 in the bottom right corner.

Note: Similar behavior is encountered when CPOL = 0. In this case the sampling edge is the rising edge of SCK, and NSS assertion and deassertion refer to this sampling edge.

27.5.12 TI mode

TI protocol in master mode

The SPI interface is compatible with the TI protocol. The FRF bit of the SPIx_CR2 register can be used to configure the SPI to be compliant with this protocol.

The clock polarity and phase are forced to conform to the TI protocol requirements whatever the values set in the SPIx_CR1 register. NSS management is also specific to the TI protocol which makes the configuration of NSS management through the SPIx_CR1 and SPIx_CR2 registers (SSM, SSI, SSOE) impossible in this case.

In slave mode, the SPI baud rate prescaler is used to control the moment when the MISO pin state changes to HiZ when the current transaction finishes (see Figure 244). Any baud rate can be used, making it possible to determine this moment with optimal flexibility. However, the baud rate is generally set to the external master clock baud rate. The delay for the MISO signal to become HiZ (\(t_{\text{release}}\)) depends on internal resynchronization and on the

baud rate value set in through the BR[2:0] bits in the SPIx_CR1 register. It is given by the formula:

\[\frac{t_{\text{baud\_rate}}}{2} + 4 \times t_{\text{pclk}} < t_{\text{release}} < \frac{t_{\text{baud\_rate}}}{2} + 6 \times t_{\text{pclk}}\]

If the slave detects a misplaced NSS pulse during a data frame transaction the TIFRE flag is set.

If the data size is equal to 4-bits or 5-bits, the master in full-duplex mode or transmit-only mode uses a protocol with one more dummy data bit added after LSB. TI NSS pulse is generated above this dummy bit clock cycle instead of the LSB in each period.

This feature is not available for Motorola SPI communications (FRF bit set to 0).

Figure 244: TI mode transfer shows the SPI communication waveforms when TI mode is selected.

Figure 244. TI mode transfer

Timing diagram for TI mode transfer showing NSS, SCK, MOSI, and MISO signals across two frames.

The diagram illustrates the timing of SPI communication in TI mode across two frames. The NSS (Slave Select) signal is active low and defines the start and end of the frames. The SCK (Serial Clock) signal is a square wave. The MOSI (Master Out Slave In) signal shows data being shifted out, starting with a 'DONT CARE' state followed by MSB to LSB. The MISO (Master In Slave Out) signal shows data being shifted in, starting with '1 or 0' followed by MSB to LSB. The diagram labels 'trigger' and 'sampling' points on the SCK signal. A release time \(t_{\text{RELEASE}}\) is indicated after the NSS signal goes high. The frames are labeled 'FRAME 1' and 'FRAME 2'. The diagram is labeled 'MS19835V2'.

Timing diagram for TI mode transfer showing NSS, SCK, MOSI, and MISO signals across two frames.

27.5.13 CRC calculation

Two separate CRC calculators are implemented in order to check the reliability of transmitted and received data. The SPI offers CRC8 or CRC16 calculation independently of the frame data length, which can be fixed to 8-bit or 16-bit. For all the other data frame lengths, no CRC is available.

CRC principle

CRC calculation is enabled by setting the CRCEN bit in the SPIx_CR1 register before the SPI is enabled (SPE = 1). The CRC value is calculated using an odd programmable polynomial on each bit. The calculation is processed on the sampling clock edge defined by the CPHA and CPOL bits in the SPIx_CR1 register. The calculated CRC value is checked automatically at the end of the data block as well as for transfer managed by CPU or by the DMA. When a mismatch is detected between the CRC calculated internally on the received data and the CRC sent by the transmitter, a CRCERR flag is set to indicate a data corruption error. The right procedure for handling the CRC calculation depends on the SPI configuration and the chosen transfer management.

Note: The polynomial value should only be odd. No even values are supported.

CRC transfer managed by CPU

Communication starts and continues normally until the last data frame has to be sent or received in the SPIx_DR register. Then CRCNEXT bit has to be set in the SPIx_CR1 register to indicate that the CRC frame transaction follows after the transaction of the currently processed data frame. The CRCNEXT bit must be set before the end of the last data frame transaction. CRC calculation is frozen during CRC transaction.

The received CRC is stored in the RXFIFO like a data byte or word. That is why in CRC mode only, the reception buffer has to be considered as a single 16-bit buffer used to receive only one data frame at a time.

A CRC-format transaction usually takes one more data frame to communicate at the end of data sequence. However, when setting an 8-bit data frame checked by 16-bit CRC, two more frames are necessary to send the complete CRC.

When the last CRC data is received, an automatic check is performed comparing the received value and the value in the SPIx_RXCRC register. Software has to check the CRCERR flag in the SPIx_SR register to determine if the data transfers were corrupted or not. Software clears the CRCERR flag by writing '0' to it.

After the CRC reception, the CRC value is stored in the RXFIFO and must be read in the SPIx_DR register in order to clear the RXNE flag.

CRC transfer managed by DMA

When SPI communication is enabled with CRC communication and DMA mode, the transmission and reception of the CRC at the end of communication is automatic (with the exception of reading CRC data in receive only mode). The CRCNEXT bit does not have to be handled by the software. The counter for the SPI transmission DMA channel has to be set to the number of data frames to transmit excluding the CRC frame. On the receiver side, the received CRC value is handled automatically by DMA at the end of the transaction but user must take care to flush out received CRC information from RXFIFO as it is always loaded into it. In full duplex mode, the counter of the reception DMA channel can be set to the number of data frames to receive including the CRC, which means, for example, in the specific case of an 8-bit data frame checked by 16-bit CRC:

\[\text{DMA\_RX} = \text{Numb\_of\_data} + 2\]

In receive only mode, the DMA reception channel counter should contain only the amount of data transferred, excluding the CRC calculation. Then based on the complete transfer from DMA, all the CRC values must be read back by software from FIFO as it works as a single buffer in this mode.

At the end of the data and CRC transfers, the CRCERR flag in the SPIx_SR register is set if corruption occurred during the transfer.

If packing mode is used, the LDMA_RX bit needs managing if the number of data is odd.

Resetting the SPIx_TXCRC and SPIx_RXCRC values

The SPIx_TXCRC and SPIx_RXCRC values are cleared automatically when new data is sampled after a CRC phase. This allows the use of DMA circular mode (not available in receive-only mode) in order to transfer data without any interruption, (several data blocks covered by intermediate CRC checking phases).

If the SPI is disabled during a communication the following sequence must be followed:

  1. 1. Disable the SPI
  2. 2. Clear the CRCEN bit
  3. 3. Enable the CRCEN bit
  4. 4. Enable the SPI

Note: When the SPI is in slave mode, the CRC calculator is sensitive to the SCK slave input clock as soon as the CRCEN bit is set, and this is the case whatever the value of the SPE bit. In order to avoid any wrong CRC calculation, the software must enable CRC calculation only when the clock is stable (in steady state). When the SPI interface is configured as a slave, the NSS internal signal needs to be kept low between the data phase and the CRC phase.

27.6 SPI interrupts

During SPI communication an interrupts can be generated by the following events:

Interrupts can be enabled and disabled separately.

Table 95. SPI interrupt requests

Interrupt eventEvent flagEnable Control bit
Transmit TXFIFO ready to be loadedTXETXEIE
Data received in RXFIFORXNERXNEIE
Master Mode fault eventMODFERRIE
Overrun errorOVR
TI frame format errorFRE

27.7 I2S functional description

27.7.1 I2S general description

The block diagram of the I2S is shown in Figure 245.

Figure 245. I2S block diagram

Figure 245: I²S block diagram showing the internal functional components and connections including Address and data bus, Tx buffer, 16-bit Shift register, Rx buffer, Communication control with status flags (BSY, OVR, MODF, CRC ERR, UDR, CH SIDE, TxE, RxNE, FRE), Master control logic, SPI baud rate generator, I²S clock generator, and control/configuration registers (I2SCFG[1:0], I2SSTD[1:0], CK POL, DATLEN[1:0], CH LEN, I2SMOD, I2SE, Bidi mode, Bidi OE, CRC EN, CRC Next, DFF, Rx only, SSM, SSI, LSB First, SPE, BR2, BR1, BR0, MSTR, CPOL, CPHA, MCKOE, ODD, I2SDIV[7:0]) with external pins MOSI/SD, MISO, NSS/WS, CK, MCK, and internal clock line I2SxCLK.
Figure 245: I²S block diagram showing the internal functional components and connections including Address and data bus, Tx buffer, 16-bit Shift register, Rx buffer, Communication control with status flags (BSY, OVR, MODF, CRC ERR, UDR, CH SIDE, TxE, RxNE, FRE), Master control logic, SPI baud rate generator, I²S clock generator, and control/configuration registers (I2SCFG[1:0], I2SSTD[1:0], CK POL, DATLEN[1:0], CH LEN, I2SMOD, I2SE, Bidi mode, Bidi OE, CRC EN, CRC Next, DFF, Rx only, SSM, SSI, LSB First, SPE, BR2, BR1, BR0, MSTR, CPOL, CPHA, MCKOE, ODD, I2SDIV[7:0]) with external pins MOSI/SD, MISO, NSS/WS, CK, MCK, and internal clock line I2SxCLK.

The SPI can function as an audio I2S interface when the I2S capability is enabled (by setting the I2SMOD bit in the SPIx_I2SCFGR register). This interface mainly uses the same pins, flags and interrupts as the SPI.

The I2S shares three common pins with the SPI:

An additional pin can be used when a master clock output is needed for some external audio devices:

The I2S uses its own clock generator to produce the communication clock when it is set in master mode. This clock generator is also the source of the master clock output. Two additional registers are available in I2S mode. One is linked to the clock generator configuration SPIx_I2SPR and the other one is a generic I2S configuration register SPIx_I2SCFGR (audio standard, slave/master mode, data format, packet frame, clock polarity, etc.).

The SPIx_CR1 register and all CRC registers are not used in the I2S mode. Likewise, the SSOE bit in the SPIx_CR2 register and the MODF and CRCERR bits in the SPIx_SR are not used.

The I2S uses the same SPI register for data transfer (SPIx_DR) in 16-bit wide mode.

27.7.2 Supported audio protocols

The three-line bus has to handle only audio data generally time-multiplexed on two channels: the right channel and the left channel. However there is only one 16-bit register for transmission or reception. So, it is up to the software to write into the data register the appropriate value corresponding to each channel side, or to read the data from the data register and to identify the corresponding channel by checking the CHSIDE bit in the SPIx_SR register. Channel left is always sent first followed by the channel right (CHSIDE has no meaning for the PCM protocol).

Four data and packet frames are available. Data may be sent with a format of:

When using 16-bit data extended on 32-bit packet, the first 16 bits (MSB) are the significant bits, the 16-bit LSB is forced to 0 without any need for software action or DMA request (only one read/write operation).

The 24-bit and 32-bit data frames need two CPU read or write operations to/from the SPIx_DR register or two DMA operations if the DMA is preferred for the application. For 24-bit data frame specifically, the 8 nonsignificant bits are extended to 32 bits with 0-bits (by hardware).

For all data formats and communication standards, the most significant bit is always sent first (MSB first).

The I2S interface supports four audio standards, configurable using the I2SSTD[1:0] and PCMSYNC bits in the SPIx_I2SCFGR register.

I2S Philips standard

For this standard, the WS signal is used to indicate which channel is being transmitted. It is activated one CK clock cycle before the first bit (MSB) is available.

Figure 246. I2S Philips protocol waveforms (16/32-bit full accuracy, CPOL = 0)

I2S Philips protocol waveforms (16/32-bit full accuracy, CPOL = 0) timing diagram showing CK, WS (transmission, reception), and SD (MSB, LSB, Channel left, Channel right, May be 16-bit or 32-bit).
I2S Philips protocol waveforms (16/32-bit full accuracy, CPOL = 0) timing diagram showing CK, WS (transmission, reception), and SD (MSB, LSB, Channel left, Channel right, May be 16-bit or 32-bit).

Data are latched on the falling edge of CK (for the transmitter) and are read on the rising edge (for the receiver). The WS signal is also latched on the falling edge of CK.

Figure 247. I2S Philips standard waveforms (24-bit frame with CPOL = 0)

I2S Philips standard waveforms (24-bit frame with CPOL = 0) timing diagram showing CK, WS (Transmission, Reception), and SD (MSB, LSB, 24-bit data, 8-bit remaining 0 forced, Channel left 32-bit, Channel right, MS19592V1).
I2S Philips standard waveforms (24-bit frame with CPOL = 0) timing diagram showing CK, WS (Transmission, Reception), and SD (MSB, LSB, 24-bit data, 8-bit remaining 0 forced, Channel left 32-bit, Channel right, MS19592V1).

This mode needs two write or read operations to/from the SPIx_DR register.

Figure 248. Transmitting 0x8EAA33

Figure 249. Receiving 0x8EAA33 Diagram showing the process of receiving 0x8EAA33. It shows a first read to the Data register resulting in 0x8EAA, followed by a second read resulting in 0x33XX. A note explains that only the 8 MSB are sent to compare the 24 bits, and the 8 LSBs have no meaning and can be anything.

First read to Data register

0x8EAA

Second read to Data register

0x33XX

Only the 8 MSB are sent
to compare the 24 bits
8 LSBs have no meaning
and can be anything

MS19594V1

Diagram showing the process of receiving 0x8EAA33. It shows a first read to the Data register resulting in 0x8EAA, followed by a second read resulting in 0x33XX. A note explains that only the 8 MSB are sent to compare the 24 bits, and the 8 LSBs have no meaning and can be anything.
Figure 250. I2S Philips standard (16-bit extended to 32-bit packet frame with CPOL = 0) Timing diagram for I2S Philips standard. It shows CK (clock), WS (word select), and SD (serial data) signals. The diagram illustrates the transmission and reception of 16-bit data, with the remaining 16 bits forced to 0 to form a 32-bit channel frame. It labels the 'Channel left 32-bit' and 'Channel right'.

CK

WS

Transmission

Reception

16-bit data

16-bit remaining 0 forced

SD

MSB

LSB

Channel left 32-bit

Channel right

MS19599V1

Timing diagram for I2S Philips standard. It shows CK (clock), WS (word select), and SD (serial data) signals. The diagram illustrates the transmission and reception of 16-bit data, with the remaining 16 bits forced to 0 to form a 32-bit channel frame. It labels the 'Channel left 32-bit' and 'Channel right'.

When 16-bit data frame extended to 32-bit channel frame is selected during the I2S configuration phase, only one access to the SPIx_DR register is required. The 16 remaining bits are forced by hardware to 0x0000 to extend the data to 32-bit format.

If the data to transmit or the received data are 0x76A3 (0x76A30000 extended to 32-bit), the operation shown in Figure 251 is required.

Figure 251. Example of 16-bit data frame extended to 32-bit channel frame Diagram showing a single access to the SPIx_DR register with the value 0x76A3.

Only one access to SPIx_DR

0x76A3

MS19595V1

Diagram showing a single access to the SPIx_DR register with the value 0x76A3.

For transmission, each time an MSB is written to SPIx_DR, the TXE flag is set and its interrupt, if allowed, is generated to load the SPIx_DR register with the new value to send. This takes place even if 0x0000 have not yet been sent because it is done by hardware.

For reception, the RXNE flag is set and its interrupt, if allowed, is generated when the first 16 MSB half-word is received.

In this way, more time is provided between two write or read operations, which prevents underrun or overrun conditions (depending on the direction of the data transfer).

MSB justified standard

For this standard, the WS signal is generated at the same time as the first data bit, which is the MSBit.

Figure 252. MSB Justified 16-bit or 32-bit full-accuracy length with CPOL = 0

Timing diagram: MSB Justified 16-bit or 32-bit full-accuracy length with CPOL = 0, illustrating CK, WS, and SD lines with transmission, reception, 16- or 32-bit data, MSB, LSB, Channel left, and Channel right (MS30100 V1).
Timing diagram: MSB Justified 16-bit or 32-bit full-accuracy length with CPOL = 0, illustrating CK, WS, and SD lines with transmission, reception, 16- or 32-bit data, MSB, LSB, Channel left, and Channel right (MS30100 V1).

Data are latched on the falling edge of CK (for transmitter) and are read on the rising edge (for the receiver).

Figure 253. MSB justified 24-bit frame length with CPOL = 0

Timing diagram: MSB justified 24-bit frame length with CPOL = 0, illustrating CK, WS, and SD lines with 24-bit data, 8-bit remaining 0 forced, Channel left 32-bit, and Channel right (MS30101V1).
Timing diagram: MSB justified 24-bit frame length with CPOL = 0, illustrating CK, WS, and SD lines with 24-bit data, 8-bit remaining 0 forced, Channel left 32-bit, and Channel right (MS30101V1).

Figure 254. MSB justified 16-bit extended to 32-bit packet frame with CPOL = 0

Timing diagram: MSB justified 16-bit extended to 32-bit packet frame with CPOL = 0, illustrating CK, WS, and SD lines with 16-bit data, 16-bit remaining 0 forced, Channel left 32-bit, and Channel right (MS30102V1).
Timing diagram: MSB justified 16-bit extended to 32-bit packet frame with CPOL = 0, illustrating CK, WS, and SD lines with 16-bit data, 16-bit remaining 0 forced, Channel left 32-bit, and Channel right (MS30102V1).

LSB justified standard

This standard is similar to the MSB justified standard (no difference for the 16-bit and 32-bit full-accuracy frame formats).

Figure 255. LSB justified 16-bit or 32-bit full-accuracy with CPOL = 0 Timing diagram: LSB justified 16-bit or 32-bit full-accuracy with CPOL = 0, illustrating CK, WS, and SD signals with Transmission and Reception phases, MSB/LSB bits for Channel left and Channel right. Reference MS30103V1.
Timing diagram: LSB justified 16-bit or 32-bit full-accuracy with CPOL = 0, illustrating CK, WS, and SD signals with Transmission and Reception phases, MSB/LSB bits for Channel left and Channel right. Reference MS30103V1.
Figure 256. LSB justified 24-bit frame length with CPOL = 0 Timing diagram: LSB justified 24-bit frame length with CPOL = 0, showing CK, WS, and SD waveforms with 8-bit data 0 forced and 24-bit remaining in Channel left 32-bit frame. Reference MS30104V1.
Timing diagram: LSB justified 24-bit frame length with CPOL = 0, showing CK, WS, and SD waveforms with 8-bit data 0 forced and 24-bit remaining in Channel left 32-bit frame. Reference MS30104V1.

If data 0x3478AE have to be transmitted, two write operations to the SPIx_DR register are required by software or by DMA. The operations are shown below.

Figure 257. Operations required to transmit 0x3478AE

First write to Data register
conditioned by TXE=1

0xXX34

Only the 8 LSB of the
half-word are significant.
A field of 0x00 is forced
instead of the 8 MSBs.

Second write to Data register
conditioned by TXE=1

0x78AE
MS19596V1

If data 0x3478AE are received, two successive read operations from the SPIx_DR register are required on each RXNE event.

Figure 258. Operations required to receive 0x3478AE

First read from Data register
conditioned by RXNE=1

0xXX34

Only the 8 LSB of the
half-word are significant.
A field of 0x00 is forced
instead of the 8 MSBs.

Second read from Data register
conditioned by RXNE=1

0x78AE
MS19597V1

Figure 259. LSB justified 16-bit extended to 32-bit packet frame with CPOL = 0

Timing diagram of LSB justified 16-bit extended to 32-bit packet frame with CPOL = 0, illustrating CK clock pulses, WS word select signal, and SD serial data with 16-bit data (0 forced) followed by 16-bit remaining data for Channel left 32-bit and Channel right.
Timing diagram of LSB justified 16-bit extended to 32-bit packet frame with CPOL = 0, illustrating CK clock pulses, WS word select signal, and SD serial data with 16-bit data (0 forced) followed by 16-bit remaining data for Channel left 32-bit and Channel right.

When 16-bit data frame extended to 32-bit channel frame is selected during the I2S configuration phase, Only one access to the SPIx_DR register is required. The 16 remaining bits are forced by hardware to 0x0000 to extend the data to 32-bit format. In this case it corresponds to the half-word MSB.

If the data to transmit or the received data are 0x76A3 (0x0000 76A3 extended to 32-bit), the operation shown in Figure 260 is required.

Figure 260. Example of 16-bit data frame extended to 32-bit channel frame

Diagram showing 'Only one access to the SPIx-DR register' containing the 16-bit data box '0x76A3'.
Diagram showing 'Only one access to the SPIx-DR register' containing the 16-bit data box '0x76A3'.

In transmission mode, when a TXE event occurs, the application has to write the data to be transmitted (in this case 0x76A3). The 0x000 field is transmitted first (extension on 32-bit). The TXE flag is set again as soon as the effective data (0x76A3) is sent on SD.

In reception mode, RXNE is asserted as soon as the significant half-word is received (and not the 0x0000 field).

In this way, more time is provided between two write or read operations to prevent underrun or overrun conditions.

PCM standard

For the PCM standard, there is no need to use channel-side information. The two PCM modes (short and long frame) are available and configurable using the PCMSYNC bit in SPIx_I2SCFGR register.

Figure 261. PCM standard waveforms (16-bit) Figure 261: PCM standard waveforms (16-bit). The diagram shows four signals: CK (clock), WS short frame, WS long frame, and SD (data). CK is a continuous square wave. WS short frame is a single-cycle high pulse. WS long frame is a high pulse that spans 13 bits. SD shows 16-bit data words with MSB and LSB marked. Labeled MS30106V1.
Figure 261: PCM standard waveforms (16-bit). The diagram shows four signals: CK (clock), WS short frame, WS long frame, and SD (data). CK is a continuous square wave. WS short frame is a single-cycle high pulse. WS long frame is a high pulse that spans 13 bits. SD shows 16-bit data words with MSB and LSB marked. Labeled MS30106V1.

For long frame synchronization, the WS signal assertion time is fixed to 13 bits in master mode.

For short frame synchronization, the WS synchronization signal is only one cycle long.

Figure 262. PCM standard waveforms (16-bit extended to 32-bit packet frame) Figure 262: PCM standard waveforms (16-bit extended to 32-bit packet frame). The diagram shows four signals: CK, WS short frame, WS long frame, and SD. WS short frame is a single-cycle pulse. WS long frame spans Up to 13-bits. SD shows 16 bits of data with MSB and LSB indicated. Labeled MS30107V1.
Figure 262: PCM standard waveforms (16-bit extended to 32-bit packet frame). The diagram shows four signals: CK, WS short frame, WS long frame, and SD. WS short frame is a single-cycle pulse. WS long frame spans Up to 13-bits. SD shows 16 bits of data with MSB and LSB indicated. Labeled MS30107V1.

Note: For both modes (master and slave) and for both synchronizations (short and long), the number of bits between two consecutive pieces of data (and so two synchronization signals) needs to be specified (DATLEN and CHLEN bits in the SPIx_I2SCFGR register) even in slave mode.

27.7.3 Clock generator

The I2S bitrate determines the dataflow on the I2S data line and the I2S clock signal frequency.

I2S bitrate = number of bits per channel × number of channels × sampling audio frequency

For a 16-bit audio, left and right channel, the I2S bitrate is calculated as follows:

I2S bitrate = 16 × 2 × fS

It is: I2S bitrate = 32 × 2 × fS if the packet length is 32-bit wide.

Figure 263. Audio sampling frequency definition

Figure 263: Audio sampling frequency definition. A diagram showing two overlapping waveforms representing 16- or 32-bit left and right channels. A horizontal double-headed arrow between two 'sampling point' markers is labeled '32- or 64-bits' and 'F_s'. Below the diagram, it states 'F_s : audio sampling frequency' and the reference 'MS30108V1'.
Figure 263: Audio sampling frequency definition. A diagram showing two overlapping waveforms representing 16- or 32-bit left and right channels. A horizontal double-headed arrow between two 'sampling point' markers is labeled '32- or 64-bits' and 'F_s'. Below the diagram, it states 'F_s : audio sampling frequency' and the reference 'MS30108V1'.

When the master mode is configured, a specific action needs to be taken to properly program the linear divider in order to communicate with the desired audio frequency.

Figure 264. I2 S clock generator architecture Figure 264: I2S clock generator architecture. A block diagram showing the I2SxCLK input entering an '8-bit linear divider + reshaping stage'. This stage is controlled by bits MCKOE, ODD, and I2SDIV[7:0] from a register. The output goes to a 'Divider by 4' block, which then feeds into a 'Div2' block. The output of 'Div2' goes to a multiplexer (0/1) controlled by MCKOE. The output of this multiplexer goes to another multiplexer (0/1) controlled by CHLEN. The final output is CK. There is also a feedback path from CK to the MCK input of the first multiplexer. The reference 'MS30109V1' is at the bottom right.
Figure 264: I2S clock generator architecture. A block diagram showing the I2SxCLK input entering an '8-bit linear divider + reshaping stage'. This stage is controlled by bits MCKOE, ODD, and I2SDIV[7:0] from a register. The output goes to a 'Divider by 4' block, which then feeds into a 'Div2' block. The output of 'Div2' goes to a multiplexer (0/1) controlled by MCKOE. The output of this multiplexer goes to another multiplexer (0/1) controlled by CHLEN. The final output is CK. There is also a feedback path from CK to the MCK input of the first multiplexer. The reference 'MS30109V1' is at the bottom right.
  1. 1. Where x can be 2 or 3.

Figure 264 presents the communication clock architecture. The I2Sx clock is always a 32 MHz frequency clock.

Warning: In addition, it is mandatory to keep I2SxCLK frequency higher or equal to the APB clock used by the SPI/I2S block. If this condition is not respected, SPI/I2S do not work.

The audio sampling frequency may be 192 kHz, 96 kHz, 48 kHz, 44.1 kHz, 32 kHz, 22.05 kHz, 16 kHz, 11.025 kHz or 8 kHz (or any other value within this range). In order to reach the desired frequency, the linear divider needs to be programmed according to the formulas below:

When the master clock is generated (MCKOE in the SPIx_I2SPR register is set):

\[f_S = \text{I2SxCLK} / [256 * ((2 * \text{I2SDIV}) + \text{ODD})]\]

whatever the channel frame width (16-bit wide or 32-bit wide).

When the master clock is disabled (MCKOE bit cleared):

\[f_S = \text{I2SxCLK} / [(16 * 2) * ((2 * \text{I2SDIV}) + \text{ODD})]\]

when the channel frame is 16-bit wide

\[f_S = \text{I2SxCLK} / [(32 * 2) * ((2 * \text{I2SDIV}) + \text{ODD})]\]

when the channel frame is 32-bit wide

Table 96 provides example precision values for different clock configurations.

Note: Other configurations are possible that allow optimum clock precision.

Table 96. Audio frequency precision using I2SCLK = 64 MHz (continued)

I2SCLK (MHz)Data lengthI2SDIVI2SODDMCKTarget fs (Hz)Real fs (KHz)Error
641650No1920002000004.1667%
643221No1920002000004.1667%
6416101No9600095238.10.7936%
643250No960001000004.167%
6416221No4410044444.440.7811%
6432111No4410043478.261.4098%
6416311No3200031746.030.7937%
6432151No3200032258.060.8065%
6416451No2205021978.020.3264%
6432221No2205022222.220.7811%
6416621No160001600000%
6432311No1600015873.0320.7937%
6416901No1102511049.720.2243%
6432451No1102510989.010.3264%
64161250No800080000%
6432621No800080000%
641621Yes48000500004.1667%
643221Yes48000500004.1667%
641630Yes4410041666.6675.5178%
643230Yes4410041666.6675.5178%
641640Yes32000312502.3438%
643240Yes32000312502.3438%
641651Yes2205022727.273.0175%
643251Yes2205022727.273.0175%
641680Yes16000156252.3438%
643280Yes16000156252.3438%
6416111Yes1102510869.571.4098%
6432111Yes1102510869.571.4098%
6416151Yes80008064.5160.8065%
6432151Yes80008064.5160.8065%

Table 97. Audio frequency precision using I2SCLK = 32 MHz

I2SCLK (MHz)Data lengthI2SDIVI2SODDMCKTarget fs (Hz)Real fs (KHz)Error
321650No960001000004.1667%
323221No960001000004.1667%
3216101No4800047619.04760.7936%
323250No48000500004.167%
3216111No4410043478.2611.410%
323281No4410045454.5453.0715%
3216151No3200032258.06450.806%
323280No32000312502.344%
3216221No2205022222.220.781%
3232111No2205021739.13041.410%
3216311No1600015873.01590.794%
3232151No1600016129.0320.806%
3216451No1102510989.0110.326%
3232221No1102511111.1110.781%
3216621No800080000%
3232470No80007936.5080.794%
321611Yes4800041666.66713.194%
323211Yes4800041666.66713.194%
321611Yes4410041666.6675.518%
323211Yes4410041666.6675.518%
321620Yes32000312502.3438%
323220Yes32000312502.3438%
321630Yes2205020833.3335.5178%
323230Yes2205020833.3335.5178%
321640Yes16000156252.3438%
323240Yes16000156252.3438%
321651Yes1102511363.63643.0715%
323251Yes1102511363.63643.0715%
321680Yes80007812.52.344%
323280Yes80007812.52.344%

Table 98. Audio frequency precision using I2SCLK = 16 MHz

I2SCLK (MHz)Data lengthI2SDIVI2SODDMCKTarget fs (Hz)Real fs (KHz)Error
161621No960001000004.1667%
163220No960006250034.890%
161641No48000500004.167%
163221No48000500004.167%
161651No4410045454.5453.0715%
163230No4410041666.675.518%
161680No32000312502.344%
163240No32000312502.344%
1616111No2205021739.131.410%
163251No2205022727.273.071%
1616151No1600016129.0320.806%
1632151No16000156252.344%
1616221No1102511111.1110.781%
1632111No1102510869.571.409%
1616311No80007936.510.794%
1632151No80008064.520.806%
1616N/AN/AYes48000N/A-
1632N/AN/AYes48000N/A-
1616N/AN/AYes44100N/A-
1632N/AN/AYes44100N/A-
1616N/AN/AYes32000N/A-
1632N/AN/AYes32000N/A-
161630Yes22050N/A-
163230Yes22050N/A-
161620Yes16000156252.3438%
163220Yes16000156252.3438%
161630Yes1102510416.675.518%
163230Yes1102510416.675.518%
161640Yes80007812.52.344%
163240Yes80007812.52.344%

27.7.4 I2S master mode

The I2S can be configured in master mode. This means that the serial clock is generated on the CK pin as well as the Word Select signal WS. Master clock (MCK) may be output or not, controlled by the MCKOE bit in the SPIx_I2SPR register.

Procedure

  1. 1. Select the I2SDIV[7:0] bits in the SPIx_I2SPR register to define the serial clock baud rate to reach the proper audio sample frequency. The ODD bit in the SPIx_I2SPR register also has to be defined.
  2. 2. Select the CKPOL bit to define the steady level for the communication clock. Set the MCKOE bit in the SPIx_I2SPR register if the master clock MCK needs to be provided to the external DAC (STM32WL33xx only)/ADC (STM32WL33xx/31xx only) audio component (the I2SDIV and ODD values should be computed depending on the state of the MCK output, for more details refer to Section 27.7.3: Clock generator).
  3. 3. Set the I2SMOD bit in the SPIx_I2SCFGR register to activate the I2S functions and choose the I2S standard through the I2SSTD[1:0] and PCMSYNC bits, the data length through the DATLEN[1:0] bits and the number of bits per channel by configuring the CHLEN bit. Select also the I2S master mode and direction (Transmitter or Receiver) through the I2SCFG[1:0] bits in the SPIx_I2SCFGR register.
  4. 4. If needed, select all the potential interrupt sources and the DMA capabilities by writing the SPIx_CR2 register.
  5. 5. The I2SE bit in SPIx_I2SCFGR register must be set.

WS and CK are configured in output mode. MCK is also an output, if the MCKOE bit in SPIx_I2SPR is set.

Transmission sequence

The transmission sequence begins when a half-word is written into the Tx buffer.

Lets assume the first data written into the Tx buffer corresponds to the left channel data. When data are transferred from the Tx buffer to the shift register, TXE is set and data corresponding to the right channel have to be written into the Tx buffer. The CHSIDE flag indicates which channel is to be transmitted. It has a meaning when the TXE flag is set because the CHSIDE flag is updated when TXE goes high.

A full frame has to be considered as a left channel data transmission followed by a right channel data transmission. It is not possible to have a partial frame where only the left channel is sent.

The data half-word is parallel loaded into the 16-bit shift register during the first bit transmission, and then shifted out, serially, to the MOSI/SD pin, MSB first. The TXE flag is set after each transfer from the Tx buffer to the shift register and an interrupt is generated if the TXEIE bit in the SPIx_CR2 register is set.

For more details about the write operations depending on the I2S standard mode selected, refer to Section 27.7.2: Supported audio protocols.

To ensure a continuous audio data transmission, it is mandatory to write the SPIx_DR register with the next data to transmit before the end of the current transmission.

To switch off the I2S, by clearing I2SE, it is mandatory to wait for TXE = 1 and BSY = 0.

Reception sequence

The operating mode is the same as for transmission mode except for the point 3 (refer to the procedure described in Section 27.7.4: I2S master mode), where the configuration should set the master reception mode through the I2SCFG[1:0] bits.

Whatever the data or channel length, the audio data are received by 16-bit packets. This means that each time the Rx buffer is full, the RXNE flag is set and an interrupt is generated if the RXNEIE bit is set in SPIx_CR2 register. Depending on the data and channel length configuration, the audio value received for a right or left channel may result from one or two receptions into the Rx buffer.

Clearing the RXNE bit is performed by reading the SPIx_DR register.

CHSIDE is updated after each reception. It is sensitive to the WS signal generated by the I2S cell.

For more details about the read operations depending on the I2S standard mode selected, refer to Section 27.7.2: Supported audio protocols.

If data are received while the previously received data have not been read yet, an overrun is generated and the OVR flag is set. If the ERRIE bit is set in the SPIx_CR2 register, an interrupt is generated to indicate the error.

To switch off the I2S, specific actions are required to ensure that the I2S completes the transfer cycle properly without initiating a new data transfer. The sequence depends on the configuration of the data and channel lengths, and on the audio protocol mode selected. In the case of:

Note: The BSY flag is kept low during transfers.

27.7.5 I2S slave mode

For the slave configuration, the I2S can be configured in transmission or reception mode. The operating mode is following mainly the same rules as described for the I2S master configuration. In slave mode, there is no clock to be generated by the I2S interface. The

clock and WS signals are input from the external master connected to the I2S interface. There is then no need, for the user, to configure the clock.

The configuration steps to follow are listed below:

  1. 1. Set the I2SMOD bit in the SPIx_I2SCFGR register to select I2S mode and choose the I2S standard through the I2SSTD[1:0] bits, the data length through the DATLEN[1:0] bits and the number of bits per channel for the frame configuring the CHLEN bit. Select also the mode (transmission or reception) for the slave through the I2SCFG[1:0] bits in SPIx_I2SCFGR register.
  2. 2. If needed, select all the potential interrupt sources and the DMA capabilities by writing the SPIx_CR2 register.
  3. 3. The I2SE bit in SPIx_I2SCFGR register must be set.

Transmission sequence

The transmission sequence begins when the external master device sends the clock and when the NSS_WS signal requests the transfer of data. The slave has to be enabled before the external master starts the communication. The I2S data register has to be loaded before the master initiates the communication.

For the I2S, MSB justified and LSB justified modes, the first data item to be written into the data register corresponds to the data for the left channel. When the communication starts, the data are transferred from the Tx buffer to the shift register. The TXE flag is then set in order to request the right channel data to be written into the I2S data register.

The CHSIDE flag indicates which channel is to be transmitted. Compared to the master transmission mode, in slave mode, CHSIDE is sensitive to the WS signal coming from the external master. This means that the slave needs to be ready to transmit the first data before the clock is generated by the master. WS assertion corresponds to left channel transmitted first.

Note: The I2SE has to be written at least two PCLK cycles before the first clock of the master comes on the CK line.

The data half-word is parallel-loaded into the 16-bit shift register (from the internal bus) during the first bit transmission, and then shifted out serially to the MOSI/SD pin MSB first. The TXE flag is set after each transfer from the Tx buffer to the shift register and an interrupt is generated if the TXEIE bit in the SPIx_CR2 register is set.

Note that the TXE flag should be checked to be at 1 before attempting to write the Tx buffer.

For more details about the write operations depending on the I2S standard mode selected, refer to Section 27.7.2: Supported audio protocols.

To secure a continuous audio data transmission, it is mandatory to write the SPIx_DR register with the next data to transmit before the end of the current transmission. An underrun flag is set and an interrupt may be generated if the data are not written into the SPIx_DR register before the first clock edge of the next data communication. This indicates to the software that the transferred data are wrong. If the ERRIE bit is set into the SPIx_CR2 register, an interrupt is generated when the UDR flag in the SPIx_SR register goes high. In this case, it is mandatory to switch off the I2S and to restart a data transfer starting from the left channel.

To switch off the I2S, by clearing the I2SE bit, it is mandatory to wait for TXE = 1 and BSY = 0.

Reception sequence

The operating mode is the same as for the transmission mode except for the point 1 (refer to the procedure described in Section 27.7.5: I2S slave mode), where the configuration should set the master reception mode using the I2SCFG[1:0] bits in the SPIx_I2SCFGR register.

Whatever the data length or the channel length, the audio data are received by 16-bit packets. This means that each time the RX buffer is full, the RXNE flag in the SPIx_SR register is set and an interrupt is generated if the RXNEIE bit is set in the SPIx_CR2 register. Depending on the data length and channel length configuration, the audio value received for a right or left channel may result from one or two receptions into the RX buffer.

The CHSIDE flag is updated each time data are received to be read from the SPIx_DR register. It is sensitive to the external WS line managed by the external master component.

Clearing the RXNE bit is performed by reading the SPIx_DR register.

For more details about the read operations depending the I2S standard mode selected, refer to Section 27.7.2: Supported audio protocols.

If data are received while the preceding received data have not yet been read, an overrun is generated and the OVR flag is set. If the bit ERRIE is set in the SPIx_CR2 register, an interrupt is generated to indicate the error.

To switch off the I2S in reception mode, I2SE has to be cleared immediately after receiving the last RXNE = 1.

Note: The external master components should have the capability of sending/receiving data in 16-bit or 32-bit packets via an audio channel.

27.7.6 I2S error flags

There are three error flags for the I2S cell.

Underrun flag (UDR)

In slave transmission mode this flag is set when the first clock for data transmission appears while the software has not yet loaded any value into SPIx_DR. It is available when the I2SMOD bit in the SPIx_I2SCFGR register is set. An interrupt may be generated if the ERRIE bit in the SPIx_CR2 register is set.

The UDR bit is cleared by a read operation on the SPIx_SR register.

Overrun flag (OVR)

This flag is set when data are received and the previous data have not yet been read from the SPIx_DR register. As a result, the incoming data are lost. An interrupt may be generated if the ERRIE bit is set in the SPIx_CR2 register.

In this case, the receive buffer contents are not updated with the newly received data from the transmitter device. A read operation to the SPIx_DR register returns the previous correctly received data. All other subsequently transmitted half-words are lost.

Clearing the OVR bit is done by a read operation on the SPIx_DR register followed by a read access to the SPIx_SR register.

Frame error flag (FRE)

This flag can be set by hardware only if the I2S is configured in Slave mode. It is set if the external master is changing the WS line while the slave is not expecting this change. If the synchronization is lost, the following steps are required to recover from this state and resynchronize the external master device with the I2S slave device:

  1. 1. Disable the I2S.
  2. 2. Enable it again when the correct level is detected on the WS line (WS line is high in I2S mode or low for MSB- or LSB-justified or PCM modes).

Desynchronization between master and slave devices may be due to noisy environment on the SCK communication clock or on the WS frame synchronization line. An error interrupt can be generated if the ERRIE bit is set. The desynchronization flag (FRE) is cleared by software when the status register is read.

27.7.7 DMA features

In I2S mode, the DMA works in exactly the same way as it does in SPI mode. There is no difference except that the CRC feature is not available in I2S mode since there is no data transfer protection system.

27.8 I2S interrupts

Table 99 provides the list of I2S interrupts.

Table 99. I2S interrupt requests

Interrupt eventEvent flagEnable control bit
Transmit buffer empty flagTXETXEIE
Receive buffer not empty flagRXNERXNEIE
Overrun errorOVRERRIE
Underrun errorUDR
Frame error flagFRE

27.9 SPI and I2S registers

The peripheral registers can be accessed by half-words (16-bit) or words (32-bit). SPI_DR in addition by can be accessed by 8-bit access.

27.9.1 SPI control register 1 (SPIx_CR1)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
BIDI
MODE
BIDI
OE
CRC
EN
CRC
NEXT
CRCLRX
ONLY
SSMSSILSB
FIRST
SPEBR [2:0]MSTRCPOLCPHA
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 15 BIDIMODE: Bidirectional data mode enable. This bit enables half-duplex communication using common single bidirectional data line. Keep RXONLY bit clear when bidirectional mode is active.

0: 2-line unidirectional data mode selected

1: 1-line bidirectional data mode selected

Note: This bit is not used in I2S mode.

Bit 14 BIDIOE: Output enable in bidirectional mode

This bit combined with the BIDIMODE bit selects the direction of transfer in bidirectional mode

0: Output disabled (receive-only mode)

1: Output enabled (transmit-only mode)

Note: In master mode, the MOSI pin is used and in slave mode, the MISO pin is used.

This bit is not used in I2S mode.

Bit 13 CRCEN: Hardware CRC calculation enable

0: CRC calculation disabled

1: CRC calculation Enabled

Note: This bit should be written only when SPI is disabled (SPE = '0') for correct operation.

This bit is not used in I2S mode.

Bit 12 CRCNEXT: Transmit CRC next

0: Next transmit value is from Tx buffer

1: Next transmit value is from Tx CRC register

Note: This bit has to be written as soon as the last data is written in the SPIx_DR register.

This bit is not used in I2S mode.

Bit 11 CRCL: CRC length

This bit is set and cleared by software to select the CRC length.

0: 8-bit CRC length

1: 16-bit CRC length

Note: This bit should be written only when SPI is disabled (SPE = '0') for correct operation.

This bit is not used in I2S mode.

Bit 10 RXONLY: Receive only mode enabled.

This bit enables simplex communication using a single unidirectional line to receive data exclusively. Keep BIDIMODE bit clear when receive only mode is active. This bit is also useful in a multislave system in which this particular slave is not accessed, the output from the accessed slave is not corrupted.

Note: This bit is not used in I2S mode.

Bit 9 SSM: Software slave management

When the SSM bit is set, the NSS pin input is replaced with the value from the SSI bit.

Note: This bit is not used in I2S mode and SPI TI mode.

Bit 8 SSI: Internal slave select

This bit has an effect only when the SSM bit is set. The value of this bit is forced onto the NSS pin and the I/O value of the NSS pin is ignored.

Note: This bit is not used in I2S mode and SPI TI mode.

Bit 7 LSBFIRST: Frame format

Note: 1. This bit should not be changed when communication is ongoing.
2. This bit is not used in I2S mode and SPI TI mode.

Bit 6 SPE: SPI enable

Note: When disabling the SPI, follow the procedure described in Procedure for disabling the SPI.

This bit is not used in I2S mode.

Bits 5:3 BR[2:0]: Baud rate control

Note: These bits should not be changed when communication is ongoing.
This bit is not used in I2S mode.

Bit 2 MSTR: Master selection

Note: This bit should not be changed when communication is ongoing.
This bit is not used in I2S mode.

Bit 1 CPOL: Clock polarity

Note: This bit should not be changed when communication is ongoing.
This bit is not used in I2S mode and SPI TI mode.

Bit 0 CPHA: Clock phase

Note: This bit should not be changed when communication is ongoing.
This bit is not used in I2S mode and SPI TI mode.

27.9.2 SPI control register 2 (SPIx_CR2)

Address offset: 0x04

Reset value: 0x0700

1514131211109876543210
Res.LDMA_TXLDMA_RXFRXT_HDS [3:0]TXEIERXNEIEERRIEFRFNSSPSSOETXDMAENRXDMAEN
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 15 Reserved, must be kept at reset value.

Bit 14 LDMA_TX: Last DMA transfer for transmission

This bit is used in data packing mode, to define if the total number of data to transmit by DMA is odd or even. It has significance only if the TXDMAEN bit in the SPIx_CR2 register is set and if packing mode is used (data length <= 8-bit and write access to SPIx_DR is 16-bit wide). It has to be written when the SPI is disabled (SPE = 0 in the SPIx_CR1 register).

Note: Refer to Procedure for disabling the SPI if the CRCEN bit is set.
This bit is not used in I2S mode.

Bit 13 LDMA_RX: Last DMA transfer for reception

This bit is used in data packing mode, to define if the total number of data to receive by DMA is odd or even. It has significance only if the RXDMAEN bit in the SPIx_CR2 register is set and if packing mode is used (data length <= 8-bit and write access to SPIx_DR is 16-bit wide). It has to be written when the SPI is disabled (SPE = 0 in the SPIx_CR1 register).

Note: Refer to Procedure for disabling the SPI if the CRCEN bit is set.
This bit is not used in I2S mode.

Bit 12 FRXTH: FIFO reception threshold

FRXTH shall be set according the read access (16-bit or 8-bit) to the FIFO.

This bit is used to set the threshold of the RXFIFO that triggers an RXNE event

0: RXNE event is generated if the FIFO level is greater than or equal to 1/2 (16-bit)

1: RXNE event is generated if the FIFO level is greater than or equal to 1/4 (8-bit)

Note: This bit is not used in I2S mode.

Bit 11:8 DS [3:0]: Data size

These bits configure the data length for SPI transfers:

0000: Not used

0001: Not used

0010: Not used

0011: 4-bit

0100: 5-bit

0101: 6-bit

0110: 7-bit

0111: 8-bit

1000: 9-bit

1001: 10-bit

1010: 11-bit

1011: 12-bit

1100: 13-bit

1101: 14-bit

1110: 15-bit

1111: 16-bit

If software attempts to write one of the “Not used” values, they are forced to the value “0111”(8-bit).

Note: This bit is not used in I2S mode.

Bit 7 TXEIE: Tx buffer empty interrupt enable

0: TXE interrupt masked

1: TXE interrupt not masked. Used to generate an interrupt request when the TXE flag is set.

Bit 6 RXNEIE: RX buffer not empty interrupt enable

0: RXNE interrupt masked

1: RXNE interrupt not masked. Used to generate an interrupt request when the RXNE flag is set.

Bit 5 ERRIE: Error interrupt enable

This bit controls the generation of an interrupt when an error condition occurs (CRCERR, OVR, MODF in SPI mode, FRE at TI mode and UDR, OVR, and FRE in I2S mode).

0: Error interrupt is masked

1: Error interrupt is enabled

Bit 4 FRF: Frame format

0: SPI Motorola mode

1 SPI TI mode

Note: This bit must be written only when the SPI is disabled (SPE=0).

This bit is not used in I2S mode.

Bit 3 NSSP: NSS pulse management

This bit is used in master mode only. It allows the SPI to generate an NSS pulse between two consecutive data transfers when doing continuous transfers. In the case of a single data transfer, it forces the NSS pin high level after the transfer.

It has no meaning if CPHA = '1', or FRF = '1'.

0: No NSS pulse

1: NSS pulse generated

Note: 1. This bit must be written only when the SPI is disabled (SPE=0).

2. This bit is not used in I2S mode and SPI TI mode.

Bit 2 SSOE: SS output enable

0: SS output is disabled in master mode and the SPI interface can work in multimaster configuration

1: SS output is enabled in master mode and when the SPI interface is enabled. The SPI interface cannot work in a multimaster environment.

Note: This bit is not used in I2S mode and SPI TI mode.

Bit 1 TXDMAEN: Tx buffer DMA enable

When this bit is set, a DMA request is generated whenever the TXE flag is set.

0: Tx buffer DMA disabled

1: Tx buffer DMA enabled

Bit 0 RXDMAEN: Rx buffer DMA enable

When this bit is set, a DMA request is generated whenever the RXNE flag is set.

0: Rx buffer DMA disabled

1: Rx buffer DMA enabled

27.9.3 SPI status register (SPIx_SR)

Address offset: 0x08

Reset value: 0x0002

1514131211109876543210
Res.Res.Res.FTLVL[1:0]FRLVL[2:0]FREBSYOVRMODFCRC
ERR
UDRCHSIDETXERXNE
rrrrrrrrrc_w0rrrr

Bits 15:13 Reserved, must be kept at reset value.

Bits 12:11 FTLVL[1:0]: FIFO Transmission Level

These bits are set and cleared by hardware.

00: FIFO empty

01: 1/4 FIFO

10: 1/2 FIFO

11: FIFO full (considered as FULL when the FIFO threshold is greater than 1/2)

Note: These bits are not used in I2S mode.

Bits 10:9 FRLVL[1:0]: FIFO reception level

These bits are set and cleared by hardware.

00: FIFO empty

01: 1/4 FIFO

10: 1/2 FIFO

11: FIFO full

Note: These bits are not used in I2S mode and in SPI receive-only mode while CRC calculation is enabled.

Bits 8 FRE: Frame format error

This flag is used for SPI in TI slave mode and I2S slave mode. Refer to Section 27.5.10: SPI error flags and Section 27.7.6: I2S error flags.

This flag is set by hardware and reset when SPIx_SR is read by software.

0: No frame format error

1: A frame format error occurred

Bit 7 BSY: Busy flag

0: SPI (or I2S) not busy

1: SPI (or I2S) is busy in communication or Tx buffer is not empty

This flag is set and cleared by hardware.

Note: The BSY flag must be used with caution: refer to Section 27.5.9: SPI status flags and Procedure for disabling the SPI.

Bit 6 OVR: Overrun flag

0: No overrun occurred

1: Overrun occurred

This flag is set by hardware and reset by a software sequence. Refer to I2S error flags for the software sequence.

Bit 5 MODF: Mode fault

0: No mode fault occurred

1: Mode fault occurred

This flag is set by hardware and reset by a software sequence. Refer to Mode fault (MODF) for the software sequence.

27.9.4 SPI data register (SPIx_DR)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
DR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 DR[15:0]: Data register

Data received or to be transmitted

The data register serves as an interface between the Rx and Tx FIFOs. When the data register is read, RxFIFO is accessed while the write to data register accesses TxFIFO (See Section 27.5.8: Data transmission and reception procedures).

Note: Data is always right-aligned. Unused bits are ignored when writing to the register, and read as zero when the register is read. The Rx threshold setting must always correspond with the read access currently used.

27.9.5 SPI CRC polynomial register (SPIx_CRCPR)

Address offset: 0x10

Reset value: 0x0007

1514131211109876543210
CRCPOLY[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 CRCPOLY[15:0]: CRC polynomial register

This register contains the polynomial for the CRC calculation.

The CRC polynomial (0007h) is the reset value of this register. Another polynomial can be configured as required.

Note: The polynomial value should be odd only. No even value is supported.

27.9.6 SPI Rx CRC register (SPIx_RXCRCR)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
RxCRC[15:0]
rrrrrrrrrrrrrrrr

Bits 15:0 RxCRC[15:0]: Rx CRC register

When CRC calculation is enabled, the RxCRC[15:0] bits contain the computed CRC value of the subsequently received bytes. This register is reset when the CRCEN bit in SPIx_CR1 register is written to 1. The CRC is calculated serially using the polynomial programmed in the SPIx_CRCPR register.

Only the 8 LSB bits are considered when the data frame format is set to be 8-bit data (CRCL bit in the SPIx_CR1 is cleared). CRC calculation is done based on any CRC8 standard.

The entire 16-bits of this register are considered when a 16-bit data frame format is selected (CRCL bit in the SPIx_CR1 register is set). CRC calculation is done based on any CRC16 standard.

A read to this register when the BSY Flag is set could return an incorrect value.

27.9.7 SPI Tx CRC register (SPIx_TXCRCR)

Address offset: 0x18

Reset value: 0x0000

1514131211109876543210
TxCRC[15:0]
rrrrrrrrrrrrrrrr

Bits 15:0 TxCRC[15:0]: Tx CRC register

When CRC calculation is enabled, the TxCRC[7:0] bits contain the computed CRC value of the subsequently transmitted bytes. This register is reset when the CRCEN bit of SPIx_CR1 is written to 1. The CRC is calculated serially using the polynomial programmed in the SPIx_CRCPR register.

Only the 8 LSB bits are considered when the data frame format is set to be 8-bit data (CRCL bit in the SPIx_CR1 is cleared). CRC calculation is done based on any CRC8 standard.

The entire 16-bits of this register are considered when a 16-bit data frame format is selected (CRCL bit in the SPIx_CR1 register is set). CRC calculation is done based on any CRC16 standard.

Note: A read to this register when the BSY flag is set could return an incorrect value.

These bits are not used in I2S mode.

27.9.8 SPIx_I2S configuration register (SPIx_I2SCFGR)

Address offset: 0x1C

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.ASTRTENI2SMODI2SEI2SCFGPCMSYNCRes.I2SSTDCKPOLDATLENCHLEN
rwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:13 Reserved: Forced to 0 by hardware

Bit 11 I2SMOD: I2S mode selection

Note: This bit should be configured when the SPI is disabled.

Bit 10 I2SE: I2S enable

Note: This bit is not used in SPI mode.

Bits 9:8 I2SCFG: I2S configuration mode

Note: These bits should be configured when the I2S is disabled.
They are not used in SPI mode.

Bit 7 PCMSYNC: PCM frame synchronization

Note: This bit has a meaning only if I2SSTD = 11 (PCM standard is used).
It is not used in SPI mode.

Bit 6 Reserved: forced at 0 by hardware

Bits 5:4 I2SSTD: I2S standard selection

For more details on I2S standards, refer to Section 27.7.2: Supported audio protocols

Note: For correct operation, these bits should be configured when the I2S is disabled.
They are not used in SPI mode.

Bit 3 CKPOL: Steady state clock polarity

0: I2S clock steady state is low level

1: I2S clock steady state is high level

Note: For correct operation, this bit should be configured when the I2S is disabled.
It is not used in SPI mode.

Bits 2:1 DATLEN: Data length to be transferred

00: 16-bit data length

01: 24-bit data length

10: 32-bit data length

11: Not allowed

Note: For correct operation, these bits should be configured when the I2S is disabled.
They are not used in SPI mode.

Bit 0 CHLEN: Channel length (number of bits per audio channel)

0: 16-bit wide

1: 32-bit wide

The bit write operation has a meaning only if DATLEN = 00 otherwise the channel length is fixed to 32-bit by hardware whatever the value filled in.

Note: For correct operation, this bit should be configured when the I2S is disabled.
It is not used in SPI mode.

27.9.9 SPIx_I2S prescaler register (SPIx_I2SPR)

Address offset: 0x20

Reset value: 0x0002

1514131211109876543210
Res.Res.Res.Res.Res.Res.MCKOEODDI2SDIV
rwrwrw

Bits 15:10 Reserved: Forced to 0 by hardware

Bit 9 MCKOE: Master clock output enable

0: Master clock output is disabled

1: Master clock output is enabled

Note: This bit should be configured when the I2S is disabled. It is used only when the I2S is in master mode.

It is not used in SPI mode.

Bit 8 ODD: Odd factor for the prescaler

0: Real divider value is = I2SDIV *2

1: Real divider value is = (I2SDIV * 2)+1

Refer to Section 27.7.3: Clock generator

Note: This bit should be configured when the I2S is disabled. It is used only when the I2S is in master mode.

It is not used in SPI mode.

Bits 7:0 I2SDIV: I2S linear prescaler

I2SDIV [7:0] = 0 or I2SDIV [7:0] = 1 are forbidden values.

Refer to Section 27.7.3: Clock generator

Note: These bits should be configured when the I2S is disabled. They are used only when the I2S is in master mode.

They are not used in SPI mode.

27.10 SPI/I2S register map

Table 100 shows the SPI/I2S register map and reset values.

Table 100. SPI register map and reset values

OffsetRegister313029282726252423222120191817161514131211109876543210
0x00SPIx_CR1ResResResResResResResResResResResResResResResResBIDIMODEBIDIOECRCENCRCNEXTCRCLRXONLYSSMSSILSBFIRSTSPEBR [2:0]MSTRCPOLCPHA
Reset value0000000000000000
0x04SPIx_CR2ResResResResResResResResResResResResResResResResResLDMA_TXLDMA_RXFRXTHDS[3:0]TXEIERXNEIEERRIEFRFNSSPSSOETXDMAENRXDMAEN
Reset value000011100000000

Table 100. SPI register map and reset values (continued)

OffsetRegister313029282726252423222120191817161514131211109876543210
0x08SPIx_SRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.FTLV[1:0]FRLVL[1:0]FREBSYOVRMODFCRCERRUDRCHSIDETXERXNE
Reset value000000000010
0x0CSPIx_DRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DR[15:0]
Reset value0000000000000000
0x10SPIx_CRCPRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CRCPOLY[15:0]
Reset value0000000000001111
0x14SPIx_RXCRCRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.RxCRC[15:0]
Reset value0000000000000000
0x18SPIx_TXCRCRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.TxCRC[15:0]
Reset value0000000000000000
0x1CSPIx_I2SCFGRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ASTRTENI2SMODI2SEI2SCFGPCMSYNCRes.I2SSTDCKPOLDATLENCHLEN
Reset value00000000000000
0x20SPIx_I2SPRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.MCKOEODDI2SDIV
Reset value000000000010

Refer to Section 2.2.2: Memory map and register boundary addresses for the register boundary addresses.