51. Basic timers (TIM6/TIM7)

51.1 TIM6/TIM7 introduction

The basic timers TIM6/TIM7 consist in a 16-bit autoreload counter driven by a programmable prescaler.

They can be used as generic timers for time-base generation.

The basic timer can also be used for triggering the digital-to-analog converter. This is done with the trigger output of the timer.

The timers are completely independent, and do not share any resources.

51.2 TIM6/TIM7 main features

Basic timer (TIM6/TIM7) features include:

51.3 TIM6/TIM7 functional description

51.3.1 TIM6/TIM7 block diagram

Figure 655. Basic timer block diagram Block diagram of a basic timer (TIM6/TIM7) showing APB bus, Trigger controller, IRQ interface, DMA interface, Auto-reload register, PSC prescaler, and CNT counter.

Notes:

MSv62381V1

Block diagram of a basic timer (TIM6/TIM7) showing APB bus, Trigger controller, IRQ interface, DMA interface, Auto-reload register, PSC prescaler, and CNT counter.

51.3.2 TIM6/TIM7 internal signals

The table in this section summarizes the TIM inputs and outputs.

Table 551. TIM internal input/output signals
Internal signal nameSignal typeDescription
tim_pclkInputTimer APB clock
tim_ker_ckInputTimer kernel clock. This clock must be synchronous with tim_pclk (derived from the same source). The clock ratio tim_ker_ck/tim_pclk must be an integer: 1, 2, 3,..., 16 (maximum value)
tim_trgoOutputInternal trigger output. This trigger can trigger other on-chip peripherals (DAC).
tim_upd_itOutputTimer update event interrupt
tim_upd_dmaOutputTimer update dma request

51.3.3 TIM6/TIM7 clocks

The timer bus interface is clocked by the tim_pclk APB clock.

The counter clock tim_ker_ck is connected to the tim_pclk input.

The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock tim_ker_ck.

Figure 656 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.

Figure 656. Control circuit in normal mode, internal clock divided by 1

Timing diagram showing the relationship between tim_ker_ck, CEN, UG, counter initialization, tim_cnt_ck, and the Counter register values.

The diagram illustrates the control circuit's behavior in normal mode with the internal clock divided by 1. It shows the following signals over time:

The diagram shows that the counter register increments on each rising edge of tim_cnt_ck. The counter initialization signal is high during the initialization phase, and the UG signal is high during the update generation phase. The CEN signal is high throughout the operation.

Timing diagram showing the relationship between tim_ker_ck, CEN, UG, counter initialization, tim_cnt_ck, and the Counter register values.

MSv62317V2

51.3.4 Time-base unit

The main block of the programmable timer is a 16-bit upcounter with its related autoreload register. The counter clock can be divided by a prescaler.

The counter, the autoreload register and the prescaler register can be written or read by software. This is true even when the counter is running.

The time-base unit includes:

The autoreload register is preloaded. The preload register is accessed each time an attempt is made to write or read the autoreload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the autoreload preload enable bit (ARPE) in the TIMx_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.

The counter is clocked by the prescaler output tim_cnt_ck, which is enabled only when the counter enable bit (CEN) in the TIMx_CR1 register is set.

Note that the actual counter enable signal tim_cnt_en is set one clock cycle after CEN bit set.

Prescaler description

The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as the TIMx_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.

Figure 657 and Figure 658 give some examples of the counter behavior when the prescaler ratio is changed on the fly.

Figure 657. Counter timing diagram with prescaler division change from 1 to 2

Timing diagram showing the relationship between prescaler clock, counter enable, counter clock, counter register, update event, prescaler control register, prescaler buffer, and prescaler counter during a prescaler division change from 1 to 2.

The diagram illustrates the timing of various signals during a prescaler division change from 1 to 2. The signals shown are:

A vertical dashed line indicates the point where the prescaler division changes from 1 to 2. An arrow points to the transition in the Prescaler control register with the text "Write a new value in TIMx_PSC".

MSv50998V1

Timing diagram showing the relationship between prescaler clock, counter enable, counter clock, counter register, update event, prescaler control register, prescaler buffer, and prescaler counter during a prescaler division change from 1 to 2.

Figure 658. Counter timing diagram with prescaler division change from 1 to 4

Timing diagram showing the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter during a prescaler division change from 1 to 4.

The diagram illustrates the timing of a prescaler division change from 1 to 4. It shows the following signals and registers over time:

MSv50999V1

Timing diagram showing the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Update event (UEV), Prescaler control register, Prescaler buffer, and Prescaler counter during a prescaler division change from 1 to 4.

51.3.5 Counting mode

The counter counts from 0 to the autoreload value (contents of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.

An update event can be generated at each counter overflow or by setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller).

The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been written to 0, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIMx_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).

When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIMx_SR register) is set (depending on the URS bit):

The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR = 0x36.

Figure 659. Counter timing diagram, internal clock divided by 1

Timing diagram for counter with internal clock divided by 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The tim_psc_ck signal is a continuous clock. The CEN signal is an enable signal that starts at a low level and transitions to high. The tim_cnt_ck signal is the counter clock, which is identical in frequency and phase to tim_psc_ck once CEN is high. The Counter register shows the count values: it starts at 31, increments to 32, 33, 34, 35, and 36, then wraps around to 00, 01, 02, 03, 04, 05, 06, and 07. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 36 to 00. The Update event (UEV) signal is a pulse that occurs on the rising edge of tim_cnt_ck when the counter transitions from 07 to 00. The Update interrupt flag (UIF) signal is a pulse that occurs on the rising edge of tim_cnt_ck when the counter transitions from 07 to 00.

MSv50997V1

Timing diagram for counter with internal clock divided by 1. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 660. Counter timing diagram, internal clock divided by 2

Timing diagram for counter with internal clock divided by 2. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a continuous clock. The CEN signal is an enable signal that starts at a low level and transitions to high. The tim_cnt_ck signal is the counter clock, which has a frequency half that of tim_psc_ck and is phase-shifted. The Counter register shows the count values: it starts at 0034, increments to 0035, 0036, then wraps around to 0000, 0001, 0002, and 0003. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0036 to 0000. The Update event (UEV) signal is a pulse that occurs on the rising edge of tim_cnt_ck when the counter transitions from 0003 to 0000. The Update interrupt flag (UIF) signal is a pulse that occurs on the rising edge of tim_cnt_ck when the counter transitions from 0003 to 0000.

MSv62300V1

Timing diagram for counter with internal clock divided by 2. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF).

Figure 661. Counter timing diagram, internal clock divided by 4

Timing diagram for counter with internal clock divided by 4. Shows signals: tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). Counter register values: 0035, 0036, 0000, 0001. Reference: MSv62301V1.

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a high-frequency clock. The CEN (enable) signal is active low; when it transitions from high to low, the counter starts. The tim_cnt_ck signal is the divided clock, with a period four times that of tim_psc_ck. The Counter register increments on each rising edge of tim_cnt_ck. When the counter reaches 0035 and increments to 0036, it wraps around to 0000, generating a Counter overflow pulse. This overflow triggers an Update event (UEV) pulse, which in turn sets the Update interrupt flag (UIF).

MSv62301V1

Timing diagram for counter with internal clock divided by 4. Shows signals: tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). Counter register values: 0035, 0036, 0000, 0001. Reference: MSv62301V1.

Figure 662. Counter timing diagram, internal clock divided by N

Timing diagram for counter with internal clock divided by N. Shows signals: tim_psc_ck, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). Counter register values: 1F, 20, 00. Reference: MSv62302V1.

This timing diagram shows the counter operation with an internal clock divided by an arbitrary factor N. The tim_psc_ck signal is the source clock. The tim_cnt_ck signal is the divided clock. The Counter register increments on each rising edge of tim_cnt_ck. The diagram shows the counter transitioning from 1F to 20, and then wrapping around to 00, which generates a Counter overflow pulse. This overflow triggers an Update event (UEV) pulse, which sets the Update interrupt flag (UIF).

MSv62302V1

Timing diagram for counter with internal clock divided by N. Shows signals: tim_psc_ck, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), and Update interrupt flag (UIF). Counter register values: 1F, 20, 00. Reference: MSv62302V1.

Figure 663. Counter timing diagram, update event when ARPE = 0 (TIMx_ARR not preloaded)

Timing diagram for counter update event when ARPE = 0. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

The diagram illustrates the timing of an update event when ARPE = 0. The counter register is 32 bits wide, with bits 31-00 shown. The counter overflow occurs when the counter reaches 00. The update event (UEV) is generated when the counter overflow occurs. The update interrupt flag (UIF) is set when the update event occurs. The auto-reload preload register is shown with a value of FF, and a note indicates that a new value can be written to TIMx_ARR.

SignalValue / State
tim_psc_ckPeriodic clock signal
CENCounter enable signal
tim_cnt_ckCounter clock signal
Counter register31 32 33 34 35 36 00 01 02 03 04 05 06 07
Counter overflowHigh pulse at 00
Update event (UEV)High pulse at 00
Update interrupt flag (UIF)High pulse at 00
Auto-reload preload registerFF 36

Write a new value in TIMx_ARR

MSv62303V1

Timing diagram for counter update event when ARPE = 0. It shows the relationship between tim_psc_ck, CEN, tim_cnt_ck, Counter register, Counter overflow, Update event (UEV), Update interrupt flag (UIF), and Auto-reload preload register.

Figure 664. Counter timing diagram, update event when ARPE = 1 (TIMx_ARR preloaded)

Timing diagram for a counter with ARPE = 1. It shows the relationship between the prescaler clock (tim_psc_ck), counter clock (tim_cnt_ck), counter register values (F0 to 07), counter overflow, update event (UEV), update interrupt flag (UIF), and auto-reload registers (preload and shadow). A write to TIMx_ARR is shown updating the preload register, which then updates the shadow register and the counter register at the next overflow.

The diagram illustrates the timing of a counter when ARPE = 1. The counter register is preloaded with a new value from the TIMx_ARR register. The counter register values are shown as F0, F1, F2, F3, F4, F5, 00, 01, 02, 03, 04, 05, 06, 07. The counter overflow occurs when the counter reaches 07 and rolls over to 00. The update event (UEV) is generated at the overflow. The update interrupt flag (UIF) is set at the update event. The auto-reload preload register is updated with the new value (F5) when a write is performed to TIMx_ARR. The auto-reload shadow register is updated with the new value (F5) at the update event. The counter register is updated with the new value (F5) at the next overflow.

Write a new value in TIMx_ARR

MSv62304V1

Timing diagram for a counter with ARPE = 1. It shows the relationship between the prescaler clock (tim_psc_ck), counter clock (tim_cnt_ck), counter register values (F0 to 07), counter overflow, update event (UEV), update interrupt flag (UIF), and auto-reload registers (preload and shadow). A write to TIMx_ARR is shown updating the preload register, which then updates the shadow register and the counter register at the next overflow.

Dithering mode

The time base effective resolution can be increased by enabling the dithering mode, using the DITHER bit in the TIMx_CR1 register. This affects the way the TIMx_ARR is behaving, and is useful for adjusting the average counter period when the timer is used as a trigger (typically for a DAC).

The operating principle is to have the actual ARR value slightly changed (adding or not one timer clock period) over 16 consecutive counting periods, with predefined patterns. This allows a 16-fold resolution increase, considering the average counting period.

Figure 665 presents the dithering principle applied to four consecutive counting periods.

Timing diagram showing dithering principle over four consecutive counting periods. It illustrates how the period T is adjusted around an average value of 12 to achieve a fractional resolution. The diagram shows five rows of periods: Row 1 (T = 12) has four periods of 12. Row 2 (T = 12+1/4) has one period of 13 followed by three of 12. Row 3 (T = 12+1/2) has two periods of 13 and two of 12. Row 4 (T = 12+3/4) has three periods of 13 and one of 12. Row 5 (T = 13) has four periods of 13. Vertical dashed lines align the start of each period across the rows. The label 'MSv47466V1' is at the bottom right.

Figure 665. Dithering principle

Timing diagram showing dithering principle over four consecutive counting periods. It illustrates how the period T is adjusted around an average value of 12 to achieve a fractional resolution. The diagram shows five rows of periods: Row 1 (T = 12) has four periods of 12. Row 2 (T = 12+1/4) has one period of 13 followed by three of 12. Row 3 (T = 12+1/2) has two periods of 13 and two of 12. Row 4 (T = 12+3/4) has three periods of 13 and one of 12. Row 5 (T = 13) has four periods of 13. Vertical dashed lines align the start of each period across the rows. The label 'MSv47466V1' is at the bottom right.

When the dithering mode is enabled, the register coding is changed as follows (see Figure 666 for example):

Note: The following sequence must be followed when resetting the DITHEN bit:
1. CEN and ARPE bits must be reset
2. The DITHEN bit must be reset
3. The CEN bit can be set (eventually with ARPE = 1).

Figure 666. Data format and register coding in dithering mode

Diagram showing register format and an example in dithering mode. Register format in dithering mode consists of b19 to b4 as MSB: 16-bits, integer part, and b3 to b0 as LSB: 4-bits fractional part. The Example shows total value 326 split into 20 in the integer part and 6 in the fractional part, with arrows indicating 'Base compare value is 20 during 16 periods' and 'Additional 6 cycles are spread over the 16 periods'. Reference ID MSv45753V2 at bottom right.
Diagram showing register format and an example in dithering mode. Register format in dithering mode consists of b19 to b4 as MSB: 16-bits, integer part, and b3 to b0 as LSB: 4-bits fractional part. The Example shows total value 326 split into 20 in the integer part and 6 in the fractional part, with arrows indicating 'Base compare value is 20 during 16 periods' and 'Additional 6 cycles are spread over the 16 periods'. Reference ID MSv45753V2 at bottom right.

The minimum frequency is given by the following formula:

\[\text{Resolution} = \frac{\text{F}_{\text{Tim}}}{\text{F}_{\text{pwm}}} \Rightarrow \text{F}_{\text{pwmMin}} = \frac{\text{F}_{\text{Tim}}}{\text{Max}_{\text{Resolution}}}\]

\[\text{Dithering mode disabled: } \text{F}_{\text{pwmMin}} = \frac{\text{F}_{\text{Tim}}}{65536}\]

\[\text{Dithering mode enabled: } \text{F}_{\text{pwmMin}} = \frac{\text{F}_{\text{Tim}}}{65535 + \frac{15}{16}}\]

Note: The maximum TIMx_ARR value is limited to 0xFFFEF in dithering mode (corresponds to 65534 for the integer part and 15 for the dithered part).

As shown on Figure 667, the dithering mode is used to increase the PWM resolution whatever the PWM frequency.

Figure 667. FCnt resolution vs frequency

Graph showing Resolution vs F_Cnt for Dithering and No Dithering modes. The y-axis is Resolution with markers for 16-bit and 20-bit. The x-axis is F_Cnt with a marker for F_Cnt min. Two curves are shown: 'Dithering' which starts at 20-bit resolution and 'No Dithering' which starts at 16-bit resolution. Both curves decrease as frequency increases.
Graph showing Resolution vs F_Cnt for Dithering and No Dithering modes. The y-axis is Resolution with markers for 16-bit and 20-bit. The x-axis is F_Cnt with a marker for F_Cnt min. Two curves are shown: 'Dithering' which starts at 20-bit resolution and 'No Dithering' which starts at 16-bit resolution. Both curves decrease as frequency increases.

MSv50910V1

The period changes are spread over 16 consecutive periods, as described in Figure 668.

Figure 668. PWM dithering pattern

Diagram showing PWM dithering pattern over 16 counter periods. The 'Counter period' row shows periods 1 through 16 represented by triangular waveform shapes. The 'ARR value' row shows a constant value of 643. The 'Auto-Reload value' row shows a sequence of values: 41, 40, 40, 40, 41, 40, 40, 40, 41, 40, 40, 40, 40, 40, 40, 40.
Diagram showing PWM dithering pattern over 16 counter periods. The 'Counter period' row shows periods 1 through 16 represented by triangular waveform shapes. The 'ARR value' row shows a constant value of 643. The 'Auto-Reload value' row shows a sequence of values: 41, 40, 40, 40, 41, 40, 40, 40, 41, 40, 40, 40, 40, 40, 40, 40.

MSv47465V1

The autoreload and compare values increments are spread following the specific patterns described in Table 552. The dithering sequence is done to have increments distributed as evenly as possible and minimize the overall ripple.

Table 552. TIMx_ARR register change dithering pattern

-PWM period
12345678910111213141516
LSB value12345678910111213141516
0000----------------
0001+1---------------
0010+1-------+1-------
0011+1---+1---+1-------
0100+1---+1---+1---+1---
0101+1-+1-+1---+1---+1---
0110+1-+1-+1---+1-+1-+1---
0111+1-+1-+1-+1-+1-+1-+1---
1000+1-+1-+1-+1-+1-+1-+1-+1-
1001+1+1+1-+1-+1-+1-+1-+1-+1-
1010+1+1+1-+1-+1-+1+1+1-+1-+1-
1011+1+1+1-+1+1+1-+1+1+1-+1-+1-
1100+1+1+1-+1+1+1-+1+1+1-+1+1+1-
1101+1+1+1+1+1+1+1-+1+1+1-+1+1+1-
1110+1+1+1+1+1+1+1-+1+1+1+1+1+1+1-
1111+1+1+1+1+1+1+1+1+1+1+1+1+1+1+1-

51.3.6 UIF bit remapping

The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the update interrupt flag UIF into the timer counter register's bit 31 (TIMxCNT[31]). This is used to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (update interrupt).

There is no latency between the assertions of the UIF and UIFCPY flags.

51.3.7 ADC triggers

The timer can generate an ADC triggering event with various internal signals, such as reset, enable or compare events.

Note: The clock of the slave peripherals (such as timer, ADC) receiving the tim_trgo signal must be enabled prior to receiving events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.

51.3.8 TIM6/TIM7 DMA requests

The TIM6/TIM7 can generate a single DMA request, as shown in Table 553.

Table 553. DMA request

DMA acronymDMA requestEnable control bit
tim_upd_dmaUpdateUDE

51.3.9 Debug mode

When the microcontroller enters debug mode (Cortex®-M33 core halted), the TIMx counter can either continue to work normally or be stopped.

The behavior in debug mode can be programmed with a dedicated configuration bit per timer in the Debug support (DBG) module.

For more details, refer to section Debug support (DBG).

51.3.10 TIM6/TIM7 low-power modes

Table 554. Effect of low-power modes on TIM6/TIM7

ModeDescription
SleepNo effect, peripheral is active. The interrupts can cause the device to exit from Sleep mode.
StopThe timer operation is stopped and the register content is kept. No interrupt can be generated.
StandbyThe timer is powered-down and must be reinitialized after exiting the Standby mode.

51.3.11 TIM6/TIM7 interrupts

The TIM6/TIM7 can generate a single interrupt, as shown in Table 555.

Table 555. Interrupt request

Interrupt acronymInterrupt eventEvent flagEnable control bitInterrupt clear methodExit from Sleep modeExit from Stop and Standby mode
TIM6
TIM7
UpdateUIFUIEwrite 0 in UIFYesNo

51.4 TIM6/TIM7 registers

Refer to Section 1.2 for a list of abbreviations used in register descriptions.

The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).

51.4.1 TIMx control register 1 (TIMx_CR1)(x = 6 to 7)

Address offset: 0x00

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.DITH
EN
UIFRE
MAP
Res.Res.Res.ARPERes.Res.Res.OPMURSUDISCEN
rwrwrwrwrwrwrw

Bits 15:13 Reserved, must be kept at reset value.

Bit 12 DITHEN: Dithering enable

0: Dithering disabled

1: Dithering enabled

Note: The DITHEN bit can only be modified when CEN bit is reset.

Bit 11 UIFREMAP: UIF status bit remapping

0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.

1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.

Bits 10:8 Reserved, must be kept at reset value.

Bit 7 ARPE: Auto-reload preload enable

0: TIMx_ARR register is not buffered.

1: TIMx_ARR register is buffered.

Bits 6:4 Reserved, must be kept at reset value.

Bit 3 OPM: One-pulse mode

0: Counter is not stopped at update event

1: Counter stops counting at the next update event (clearing the CEN bit).

Bit 2 URS: Update request source

This bit is set and cleared by software to select the UEV event sources.

0: Any of the following events generates an update interrupt or DMA request if enabled.

These events can be:

1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.

Bit 1 UDIS: Update disable

This bit is set and cleared by software to enable/disable UEV event generation.

0: UEV enabled. The Update (UEV) event is generated by one of the following events:

Buffered registers are then loaded with their preload values.

1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.

Bit 0 CEN: Counter enable

0: Counter disabled

1: Counter enabled

CEN is cleared automatically in one-pulse mode, when an update event occurs.

51.4.2 TIMx control register 2 (TIMx_CR2)(x = 6 to 7)

Address offset: 0x04

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.MMS[2:0]Res.Res.Res.Res.
rwrwrw

Bits 15:7 Reserved, must be kept at reset value.

Bits 6:4 MMS[2:0]: Master mode selection

These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:

000:Reset - the UG bit from the TIMx_EGR register is used as a trigger output (tim_trgo).

001:Enable - the Counter enable signal, tim_cnt_en, is used as a trigger output (tim_trgo). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated when the CEN control bit is written.

010:Update - The update event is selected as a trigger output (tim_trgo). For instance a master timer can then be used as a prescaler for a slave timer.

Note: The clock of the slave timer or the peripheral receiving the tim_trgo must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.

Bits 3:0 Reserved, must be kept at reset value.

51.4.3 TIMx DMA/Interrupt enable register (TIMx_DIER)(x = 6 to 7)

Address offset: 0x0C

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.UDERes.Res.Res.Res.Res.Res.Res.UIE
rwrw

Bits 15:9 Reserved, must be kept at reset value.

Bit 8 UDE: Update DMA request enable

0: Update DMA request disabled.

1: Update DMA request enabled.

Bits 7:1 Reserved, must be kept at reset value.

Bit 0 UIE: Update interrupt enable

0: Update interrupt disabled.

1: Update interrupt enabled.

51.4.4 TIMx status register (TIMx_SR)(x = 6 to 7)

Address offset: 0x10

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UIF
rc_w0

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UIF: Update interrupt flag

This bit is set by hardware on an update event. It is cleared by software.

0: No update occurred.

1: Update interrupt pending. This bit is set by hardware when the registers are updated:

–On counter overflow if UDIS = 0 in the TIMx_CR1 register.

–When CNT is reinitialized by software using the UG bit in the TIMx_EGR register, if URS = 0 and UDIS = 0 in the TIMx_CR1 register.

51.4.5 TIMx event generation register (TIMx_EGR)(x = 6 to 7)

Address offset: 0x14

Reset value: 0x0000

1514131211109876543210
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UG
w

Bits 15:1 Reserved, must be kept at reset value.

Bit 0 UG: Update generation

This bit can be set by software, it is automatically cleared by hardware.

0: No action.

1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).

51.4.6 TIMx counter (TIMx_CNT)(x = 6 to 7)

Address offset: 0x24

Reset value: 0x0000 0000

31302928272625242322212019181716
UIF
CPY
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.
r
1514131211109876543210
CNT[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bit 31 UIFCPY: UIF copy

This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.

Bits 30:16 Reserved, must be kept at reset value.

Bits 15:0 CNT[15:0]: Counter value

Non-dithering mode (DITHEN = 0)

The register holds the counter value.

Dithering mode (DITHEN = 1)

The register only holds the non-dithered part in CNT[15:0]. The fractional part is not available.

51.4.7 TIMx prescaler (TIMx_PSC)(x = 6 to 7)

Address offset: 0x28

Reset value: 0x0000

1514131211109876543210
PSC[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 15:0 PSC[15:0]: Prescaler value

The counter clock frequency \(f_{tim\_cnt\_ck}\) is equal to \(f_{tim\_psc\_ck} / (PSC[15:0] + 1)\).

PSC contains the value to be loaded into the active prescaler register at each update event. (including when the counter is cleared through UG bit of TIMx_EGR register).

51.4.8 TIMx autoreload register (TIMx_ARR)(x = 6 to 7)

Address offset: 0x2C

Reset value: 0x0000 FFFF

31302928272625242322212019181716
Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ARR[19:16]
rwrwrwrw
1514131211109876543210
ARR[15:0]
rwrwrwrwrwrwrwrwrwrwrwrwrwrwrwrw

Bits 31:20 Reserved, must be kept at reset value.

Bits 19:0 ARR[19:0]: Auto-reload value

ARR is the value to be loaded into the actual auto-reload register.

Refer to Section 51.3.4: Time-base unit for more details about ARR update and behavior.

The counter is blocked while the auto-reload value is null.

Non-dithering mode (DITHEN = 0)

The register holds the auto-reload value in ARR[15:0]. The ARR[19:16] bits are reserved.

Dithering mode (DITHEN = 1)

The register holds the integer part in ARR[19:4]. The ARR[3:0] bitfield contains the dithered part.

51.4.9 TIMx register map

TIMx registers are mapped as 16-bit addressable registers as described in the table below:

Table 556. TIMx register map and reset values

OffsetRegister name313029282726252423222120191817161514131211109876543210
0x00TIMx_CR1Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.DITHENUIFREMARes.Res.Res.ARPERes.Res.Res.Res.Res.Res.CEN
Reset value0000
0x04TIMx_CR2Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.MMS [2:0]Res.Res.Res.Res.
Reset value000
0x08Reserved
0x0CTIMx_DIERRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UDERes.Res.Res.Res.Res.Res.Res.UIE
Reset value00
0x10TIMx_SRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UIF
Reset value0
0x14TIMx_EGRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.UG
Reset value0
0x18-0x20Reserved
0x24TIMx_CNTUIFCPY or Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.CNT[15:0]
Reset value00000000000000
0x28TIMx_PSCRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.PSC[15:0]
Reset value0000000000000
0x2CTIMx_ARRRes.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.Res.ARR[19:0]
Reset value00001111111111111111

Refer to Section 2.3: Memory organization for the register boundary addresses.