33. Basic timers (TIM6/TIM7)
33.1 TIM6/TIM7 introduction
The basic timers TIM6/TIM7 consist in a 16-bit autoreload counter driven by a programmable prescaler.
They can be used as generic timers for time-base generation.
The basic timer can also be used for triggering the digital-to-analog converter. This is done with the trigger output of the timer.
The timers are completely independent, and do not share any resources.
33.2 TIM6/TIM7 main features
Basic timer (TIM6/TIM7) features include:
- • 16-bit autoreload upcounter.
- • 16-bit programmable prescaler used to divide (also “on the fly”) the counter clock frequency by any factor between 1 and 65535.
- • Synchronization circuit to trigger the DAC.
- • Interrupt/DMA generation on the update event: counter overflow.
- • ADC synchronization for jitter-free sampling points.
33.3 TIM6/TIM7 functional description
33.3.1 TIM6/TIM7 block diagram
Figure 418. Basic timer block diagram

Notes:
Reg Preload registers transferred to active registers on U event according to control bit
Event
Interrupt & DMA
MSv62381V1
33.3.2 TIM6/TIM7 internal signals
The table in this section summarizes the TIM inputs and outputs.
Table 328. TIM internal input/output signals
| Internal signal name | Signal type | Description |
|---|---|---|
| tim_pclk | Input | Timer APB clock |
| tim_ker_ck | Input | Timer kernel clock. This clock must be synchronous with tim_pclk (derived from the same source). The clock ratio tim_ker_ck/tim_pclk must be an integer: 1, 2, 3,..., 16 (maximum value) |
| tim_trgo | Output | Internal trigger output. This trigger can trigger other on-chip peripherals (DAC). |
| tim_upd_it | Output | Timer update event interrupt |
| tim_upd_dma | Output | Timer update dma request |
33.3.3 TIM6/TIM7 clocks
The timer bus interface is clocked by the tim_pclk APB clock.
The counter clock tim_ker_ck is connected to the tim_pclk input.
The CEN (in the TIM_CR1 register) and UG bits (in the TIM_EGR register) are actual control bits and can be changed only by software (except for UG that remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock tim_ker_ck.
Figure 419 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.
Figure 419. Control circuit in normal mode, internal clock divided by 1

The diagram illustrates the timing relationship between various signals in normal mode with the internal clock divided by 1. The tim_ker_ck signal is a continuous square wave. The CEN signal is a high pulse that initiates the counter. The UG signal is a high pulse that triggers the counter initialization. The counter initialization (internal) signal is a high pulse that occurs after the UG signal. The tim_cnt_ck and tim_psc_ck signals are square waves that are synchronized with the tim_ker_ck signal. The Counter register is shown as a sequence of 16-bit words (31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07). The counter register is updated on the rising edge of the tim_ker_ck signal. The counter register is shown as a sequence of 16-bit words (31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07). The counter register is updated on the rising edge of the tim_ker_ck signal.
33.3.4 Time-base unit
The main block of the programmable timer is a 16-bit upcounter with its related autoreload register. The counter clock can be divided by a prescaler.
The counter, the autoreload register and the prescaler register can be written or read by software. This is true even when the counter is running.
The time-base unit includes:
- • Counter register (
TIM_CNT) - • Prescaler register (
TIM_PSC) - • Auto-Reload register (
TIM_ARR).
The autoreload register is preloaded. The preload register is accessed each time an attempt is made to write or read the autoreload register. The contents of the preload register are transferred into the shadow register permanently or at each update event UEV, depending on the autoreload preload enable bit (ARPE) in the TIM_CR1 register. The update event is sent when the counter reaches the overflow value and if the UDIS bit equals 0 in the TIM_CR1 register. It can also be generated by software. The generation of the update event is described in detail for each configuration.
Note: An update overrun status bit (UIOVRF in TIM_SR register) indicates that an update request occurred while an update interrupt is pending (update interrupt flag set). This bit is useful when debugging closed loop applications, to indicate that:
- the update interrupt service routine is too long with respect to the interval between consecutive update events
- the update interrupt service routine was served too late with respect to the subsequent update event
The counter is clocked by the prescaler output tim_cnt_ck, which is enabled only when the counter enable bit (CEN) in the TIM_CR1 register is set.
Note that the actual counter enable signal tim_cnt_en is set one clock cycle after CEN bit set.
Prescaler description
The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIM_PSC register). It can be changed on the fly as the TIM_PSC control register is buffered. The new prescaler ratio is taken into account at the next update event.
Figure 420 and Figure 421 give some examples of the counter behavior when the prescaler ratio is changed on the fly.
Figure 420. Counter timing diagram with prescaler division change from 1 to 2

Figure 421. Counter timing diagram with prescaler division change from 1 to 4

The diagram illustrates the timing of a prescaler division change from 1 to 4. It shows the following signals and registers over time:
- tim_psc_ck: The prescaler clock signal.
- CEN: The counter enable signal, which is high during the active period.
- tim_cnt_ck: The counter clock signal, derived from tim_psc_ck.
- Counter register: Shows the counter values F7, F8, F9, FA, FB, FC, 00, and 01. An update event (UEV) occurs at the end of the FC cycle.
- Update event (UEV): A pulse occurs at the end of the FC cycle.
- Prescaler control register: Shows the value 0 before the change and 3 after the change. An arrow points to the transition with the label "Write a new value in TIM_PSC".
- Prescaler buffer: Shows the value 0 before the change and 3 after the change.
- Prescaler counter: Shows the prescaler counter values 0, 0, 1, 2, 3, 0, 1, 2, 3. The counter restarts at 0 after the update event.
MSv80082V1
33.3.5 Counting mode
The counter counts from 0 to the autoreload value (contents of the TIM_ARR register), then restarts from 0 and generates a counter overflow event.
An update event can be generated at each counter overflow or by setting the UG bit in the TIM_EGR register (by software or by using the slave mode controller).
The UEV event can be disabled by software by setting the UDIS bit in the TIM_CR1 register. This avoids updating the shadow registers while writing new values into the preload registers. In this way, no update event occurs until the UDIS bit has been written to 0, however, the counter and the prescaler counter both restart from 0 (but the prescale rate does not change). In addition, if the URS (update request selection) bit in the TIM_CR1 register is set, setting the UG bit generates an update event UEV, but the UIF flag is not set (so no interrupt or DMA request is sent).
When an update event occurs, all the registers are updated and the update flag (UIF bit in the TIM_SR register) is set (depending on the URS bit):
- • The buffer of the prescaler is reloaded with the preload value (contents of the TIM_PSC register).
- • The autoreload shadow register is updated with the preload value (TIM_ARR).
The following figures show some examples of the counter behavior for different clock frequencies when TIM_ARR = 0x36.
Figure 422. Counter timing diagram, internal clock divided by 1

This timing diagram illustrates the operation of a counter when the internal clock is divided by 1. The tim_psc_ck signal is a continuous square wave. The CEN signal is a low-to-high pulse that enables the counter. The tim_cnt_ck signal is a square wave with the same frequency as tim_psc_ck. The Counter register shows the count values: it starts at 31, increments to 32, 33, 34, 35, 36, and then wraps around to 00, 01, 02, 03, 04, 05, 06, 07. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 36 to 00. The Update event (UEV) pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 07 to 00. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse. Vertical dashed lines indicate the timing of these events relative to the clock edges.
MSv50997V1
Figure 423. Counter timing diagram, internal clock divided by 2

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The tim_psc_ck signal is a continuous square wave. The CEN signal is a low-to-high pulse that enables the counter. The tim_cnt_ck signal is a square wave with half the frequency of tim_psc_ck. The Counter register shows the count values: it starts at 0034, increments to 0035, 0036, and then wraps around to 0000, 0001, 0002, 0003. A Counter overflow pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0036 to 0000. The Update event (UEV) pulse occurs on the rising edge of tim_cnt_ck when the counter transitions from 0003 to 0000. The Update interrupt flag (UIF) is set high on the rising edge of the UEV pulse. Vertical dashed lines indicate the timing of these events relative to the clock edges.
MSv62300V1
Figure 424. Counter timing diagram, internal clock divided by 4

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The tim_psc_ck signal is a continuous clock. The CEN signal is an enable signal that starts high and then goes low. The tim_cnt_ck signal is the prescaled clock, which has a frequency 1/4 of tim_psc_ck. The Counter register shows the count values: 0035, 0036, 0000, and 0001. The Counter overflow signal is high when the counter reaches its maximum value (0035) and then rolls over to 0000. The Update event (UEV) signal is high when an update event occurs, which happens when the counter rolls over. The Update interrupt flag (UIF) signal is high when an update interrupt is generated, which happens when the counter rolls over and the CEN signal is high.
| Signal | Value/State |
|---|---|
| tim_psc_ck | Continuous clock |
| CEN | High, then Low |
| tim_cnt_ck | Prescaled clock (1/4 frequency) |
| Counter register | 0035, 0036, 0000, 0001 |
| Counter overflow | High at rollover |
| Update event (UEV) | High at rollover |
| Update interrupt flag (UIF) | High at rollover |
MSv62301V1
Figure 425. Counter timing diagram, internal clock divided by N

This timing diagram illustrates the operation of a counter when the internal clock is divided by N. The tim_psc_ck signal is a continuous clock. The tim_cnt_ck signal is the prescaled clock, which has a frequency 1/N of tim_psc_ck. The Counter register shows the count values: 1F, 20, and 00. The Counter overflow signal is high when the counter reaches its maximum value (1F) and then rolls over to 00. The Update event (UEV) signal is high when an update event occurs, which happens when the counter rolls over. The Update interrupt flag (UIF) signal is high when an update interrupt is generated, which happens when the counter rolls over and the CEN signal is high.
| Signal | Value/State |
|---|---|
| tim_psc_ck | Continuous clock |
| tim_cnt_ck | Prescaled clock (1/N frequency) |
| Counter register | 1F, 20, 00 |
| Counter overflow | High at rollover |
| Update event (UEV) | High at rollover |
| Update interrupt flag (UIF) | High at rollover |
MSv62302V1
Figure 426. Counter timing diagram, update event when ARPE = 0 (TIM_ARR not preloaded)

The diagram illustrates the timing of a counter update event when ARPE = 0 and TIM_ARR is not preloaded. The counter register is 8 bits wide, with bits 31-36 shown as a single block and bits 00-07 shown individually. The counter overflow occurs when the counter reaches 36. The update event (UEV) occurs on the rising edge of the counter overflow signal. The update interrupt flag (UIF) is set on the rising edge of the UEV. The auto-reload preload register is shown with a value of FF, and a note indicates that a new value can be written to TIM_ARR.
| Signal | Value / State |
|---|---|
| tim_psc_ck | Periodic clock signal |
| CEN | Counter enable signal |
| tim_cnt_ck | Counter clock signal |
| Counter register | Bits 31, 32, 33, 34, 35, 36, 00, 01, 02, 03, 04, 05, 06, 07 |
| Counter overflow | High pulse at bit 36 |
| Update event (UEV) | High pulse on rising edge of counter overflow |
| Update interrupt flag (UIF) | High pulse on rising edge of UEV |
| Auto-reload preload register | FF |
Write a new value in TIM_ARR
MSv80083V1
Figure 427. Counter timing diagram, update event when ARPE = 1 (TIM_ARR preloaded)

The diagram illustrates the timing of a counter when ARPE = 1. The counter register counts from F0 to F5, then overflows to 00. The counter overflow signal is high during the overflow. The update event (UEV) occurs at the end of the overflow. The update interrupt flag (UIF) is set at the end of the overflow. The auto-reload preload register is updated with a new value (F5) and the auto-reload shadow register is updated with the same value (F5) after the overflow. The counter register is then updated with the new value (F5) after the overflow.
Write a new value in TIM_ARR
MSv80084V1
Dithering mode
The time base effective resolution can be increased by enabling the dithering mode, using the DITHER bit in the TIM_CR1 register. This affects the way the TIM_ARR is behaving, and is useful for adjusting the average counter period when the timer is used as a trigger (typically for a DAC).
The operating principle is to have the actual ARR value slightly changed (adding or not one timer clock period) over 16 consecutive counting periods, with predefined patterns. This allows a 16-fold resolution increase, considering the average counting period.
Figure 428 presents the dithering principle applied to four consecutive counting periods.

Figure 428. Dithering principle
MSv47466V1
When the dithering mode is enabled, the register coding is changed as follows (see Figure 429 for example):
- • The four LSBs are coding for the enhanced resolution part (fractional part).
- • The MSBs are left-shifted to the bits 19:4 and are coding for the base value.
Note: The following sequence must be followed when resetting the DITHEN bit:
- 1. CEN and ARPE bits must be reset
- 2. The DITHEN bit must be reset
- 3. The CEN bit can be set (eventually with ARPE = 1).
Figure 429. Data format and register coding in dithering mode

MSv45753V2
The minimum frequency is given by the following formula:
Note: The maximum TIM_ARR value is limited to 0xFFFEF in dithering mode (corresponds to 65534 for the integer part and 15 for the dithered part).
As shown on Figure 430, the dithering mode is used to increase the PWM resolution whatever the PWM frequency.
Figure 430. FCnt resolution vs frequency

MSv50910V1
The period changes are spread over 16 consecutive periods, as described in Figure 431.
Figure 431. PWM dithering pattern

| Counter period | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARR value | 643 | |||||||||||||||
| Auto-Reload value | 41 | 40 | 40 | 40 | 41 | 40 | 40 | 40 | 41 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
MSv47465V1
The autoreload and compare values increments are spread following the specific patterns described in Table 329. The dithering sequence is done to have increments distributed as evenly as possible and minimize the overall ripple.
Table 329. TIM_ARR register change dithering pattern
| - | PWM period | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LSB value | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| 0000 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0001 | +1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 0010 | +1 | - | - | - | - | - | - | - | +1 | - | - | - | - | - | - | - |
| 0011 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | - | - | - | - |
| 0100 | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0101 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | - | - | +1 | - | - | - |
| 0110 | +1 | - | +1 | - | +1 | - | - | - | +1 | - | +1 | - | +1 | - | - | - |
| 0111 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | - | - |
| 1000 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1001 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - | +1 | - |
| 1010 | +1 | +1 | +1 | - | +1 | - | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1011 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | - | +1 | - |
| 1100 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1101 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | - | +1 | +1 | +1 | - |
| 1110 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
| 1111 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | +1 | - |
33.3.6 UIF bit remapping
The IUFREMAP bit in the TIM_CR1 register forces a continuous copy of the update interrupt flag UIF into the timer counter register's bit 31 (TIM_CNT[31]). This is used to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (update interrupt).
There is no latency between the assertions of the UIF and UIFCPY flags.
33.3.7 ADC triggers
The timer can generate an ADC triggering event with various internal signals, such as reset, enable or compare events.
Note: The clock of the slave peripherals (such as timer, ADC) receiving the tim_trgo signal must be enabled prior to receiving events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.
33.3.8 ADC synchronization
The timer operation can be synchronized to the ADC clock to trigger jitter-free ADC sampling. This function is enabled using the ADSYNC bit in the TIM_CR2 register.
This feature is useful when the timers and the ADCs are operating with semisynchronous clocks (clocks derived from a same source with integer ratio tim_ker_ck/adc_ker_ck), for instance adc_ker_ck = 75 MHz and tim_ker_ck = 150 MHz or 300 MHz.
ADSYNC must also be set when both peripherals are operating at the same frequency from the same clock source, when jitter-free operation is needed.
ADSYNC must not be set and jitter-free operation is not supported in the following cases:
- • When the clock ratio is not an integer (for example adc_ker_ck = 75 MHz and tim_ker_ck = 100 MHz): in this case, the sampling point jitter due to the timer to ADC signal resynchronization is 1 adc_ker_ck period maximum.
- • When the ADC is operating in asynchronous mode (adc_ker_ck uncorrelated with tim_ker_ck): in this case, the sampling point jitter due to the timer to ADC signal resynchronization is 1 adc_ker_ck period maximum.
When ADSYNC = 1, the timer operation is slightly changed: the counter enable and counter reset events are aligned to the adc_ker_ck ADC clock, to avoid any phase shift due to clocks enable in the RCC.
Jitter-free operation is guaranteed only when one of the two requirements below is met (depending on the selected trigger source).
- 1. The counter period must be a multiple of the ADC clock period
- 2. The compare value must be a multiple of the ADC clock period
Note: If none of the two above requirements are met, the trigger is still generated, but the latency is not constant and varies with the timer and ADC clocks phase shift.
Programming guidelines
The ADC synchronization feature must not be modified during run-time, once the counter is enabled and once the ADC has been configured for receiving triggers from the timer.
It is mandatory to follow the procedure below to use the ADC synchronization:
- 1. Enable the destination ADC clock
- 2. Configure the timer and set the ADSYNC bit
- 3. Configure the ADC and enable it (using ADSTART and/or JADSTART bits)
- 4. Start the timer (with the CEN counter enable bit)
33.3.9 TIM6/TIM7 DMA requests
The TIM6/TIM7 can generate a single DMA request, as shown in Table 330.
Table 330. DMA request
| DMA request signal | DMA request | Enable control bit |
|---|---|---|
| tim_upd_dma | Update | UDE |
33.3.10 Debug mode
When the microcontroller enters debug mode (Cortex-M33 core halted), the TIMx counter can either continue to work normally or be stopped.
The behavior in debug mode can be programmed with a dedicated configuration bit per timer in the Debug support (DBG) module.
For more details, refer to section Debug support (DBG).
33.3.11 TIM6/TIM7 low-power modes
Table 331. Effect of low-power modes on TIM6/TIM7
| Mode | Description |
|---|---|
| Sleep | No effect, peripheral is active. The interrupts can cause the device to exit from Sleep mode. |
| Stop | The timer operation is stopped and the register content is kept. No interrupt can be generated. |
| Standby | The timer is powered-down and must be reinitialized after exiting the Standby mode. |
33.3.12 TIM6/TIM7 interrupts
The TIM6/TIM7 can generate a single interrupt, as shown in Table 332.
Table 332. Interrupt request
| Interrupt acronym | Interrupt event | Event flag | Enable control bit | Interrupt clear method | Exit from Sleep mode | Exit from Stop and Standby mode |
|---|---|---|---|---|---|---|
| TIM6 TIM7 | Update | UIF | UIE | write 0 in UIF | Yes | No |
33.4 TIM6/TIM7 registers
Refer to Section 1.2 for a list of abbreviations used in register descriptions.
The peripheral registers can be accessed by half-words (16-bit) or words (32-bit).
33.4.1 TIM control register 1 (TIM_CR1)
Address offset: 0x00
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | DITH EN | UIFRE MAP | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN |
| rw | rw | rw | rw | rw | rw | rw |
Bits 15:13 Reserved, must be kept at reset value.
Bit 12 DITHEN: Dithering enable
0: Dithering disabled
1: Dithering enabled
Note: The DITHEN bit can only be modified when CEN bit is reset.
Bit 11 UIFREMAP: UIF status bit remapping
0: No remapping. UIF status bit is not copied to TIM_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIM_CNT register bit 31.
Bits 10:8 Reserved, must be kept at reset value.
Bit 7 ARPE: Auto-reload preload enable
0: TIM_ARR register is not buffered.
1: TIM_ARR register is buffered.
Bits 6:4 Reserved, must be kept at reset value.
Bit 3 OPM: One-pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the CEN bit).
Bit 2 URS: Update request source
This bit is set and cleared by software to select the UEV event sources.
0: Any of the following events generates an update interrupt or DMA request if enabled.
These events can be:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.
Bit 1 UDIS: Update disable
This bit is set and cleared by software to enable/disable UEV event generation.
0: UEV enabled. The Update (UEV) event is generated by one of the following events:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
Buffered registers are then loaded with their preload values.
1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.
Bit 0 CEN: Counter enable
0: Counter disabled
1: Counter enabled
CEN is cleared automatically in one-pulse mode, when an update event occurs.
33.4.2 TIM control register 2 (TIM_CR2)
Address offset: 0x04
Reset value: 0x0000 0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | AD SYNC | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| rw | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS[2:0] | Res. | Res. | Res. | Res. | ||
| rw | rw | rw | |||||||||||||
Bits 31:29 Reserved, must be kept at reset value.
Bit 28 ADSYNC: ADC synchronization
0: The timer operates independently from the ADC
1: The timer operation is synchronized with the ADC clock to provide jitter-free sampling point. This mode can be enabled only with specific ADC / timer clock relationship. Refer to Section 33.3.8 for requirements.
The ADSYNC must not modified when the counter is enabled (CEN bit is set).
Bits 27:7 Reserved, must be kept at reset value.
Bits 6:4 MMS[2:0]: Master mode selection
These bits are used to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:
000:Reset - the UG bit from the TIM_EGR register is used as a trigger output (tim_trgo).
001:Enable - the Counter enable signal, tim_cnt_en, is used as a trigger output (tim_trgo). It is useful to start several timers at the same time or to control a window in which a slave timer is enabled. The Counter Enable signal is generated when the CEN control bit is written.
010:Update - The update event is selected as a trigger output (tim_trgo). For instance a master timer can then be used as a prescaler for a slave timer.
Note: The clock of the slave timer or the peripheral receiving the tim_trgo must be enabled prior to receive events from the master timer, and must not be changed on-the-fly while triggers are received from the master timer.
Bits 3:0 Reserved, must be kept at reset value.
33.4.3 TIM DMA/interrupt enable register (TIM_DIER)
Address offset: 0x0C
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE |
| rw | rw |
Bits 15:9 Reserved, must be kept at reset value.
Bit 8 UDE: Update DMA request enable
0: Update DMA request disabled.
1: Update DMA request enabled.
Bits 7:1 Reserved, must be kept at reset value.
Bit 0 UIE: Update interrupt enable
0: Update interrupt disabled.
1: Update interrupt enabled.
33.4.4 TIM status register (TIM_SR)
Address offset: 0x10
Reset value: 0x0000 0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIOVR F | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| rc_w0 | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF |
| rc_w0 |
Bits 31:25 Reserved, must be kept at reset value.
Bit 24 UIOVRF: Update Interrupt Overrun flag
This flag is set by hardware when an update request occurs while an update interrupt is pending (update interrupt flag set). It is cleared by software by writing it to '0'.
0: No Update Interrupt Overrun
1: Update Interrupt Overrun
Bits 23:1 Reserved, must be kept at reset value.
Bit 0 UIF: Update interrupt flag
This bit is set by hardware on an update event. It is cleared by software.
0: No update occurred.
1: Update interrupt pending. This bit is set by hardware when the registers are updated:
–On counter overflow if UDIS = 0 in the TIM_CR1 register.
–When CNT is reinitialized by software using the UG bit in the TIM_EGR register, if URS = 0 and UDIS = 0 in the TIM_CR1 register.
33.4.5 TIM event generation register (TIM_EGR)
Address offset: 0x14
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG |
| w |
Bits 15:1 Reserved, must be kept at reset value.
Bit 0 UG: Update generation
This bit can be set by software, it is automatically cleared by hardware.
0: No action.
1: Re-initializes the timer counter and generates an update of the registers. Note that the prescaler counter is cleared too (but the prescaler ratio is not affected).
33.4.6 TIM counter (TIM_CNT)
Address offset: 0x24
Reset value: 0x0000 0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| UIF CPY | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| r | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CNT[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bit 31 UIFCPY: UIF copy
This bit is a read-only copy of the UIF bit of the TIM_ISR register. If the UIFREMAP bit in TIM_CR1 is reset, bit 31 is reserved and read as 0.
Bits 30:16 Reserved, must be kept at reset value.
Bits 15:0 CNT[15:0]: Counter value
Non-dithering mode (DITHEN = 0)
The register holds the counter value.
Dithering mode (DITHEN = 1)
The register only holds the non-dithered part in CNT[15:0]. The fractional part is not available.
33.4.7 TIM prescaler (TIM_PSC)
Address offset: 0x28
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| PSC[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 PSC[15:0]: Prescaler value
The counter clock frequency \(f_{tim\_cnt\_ck}\) is equal to \(f_{tim\_psc\_ck} / (PSC[15:0] + 1)\).
PSC contains the value to be loaded into the active prescaler register at each update event. (including when the counter is cleared through UG bit of TIM_EGR register.
33.4.8 TIM autoreload register (TIM_ARR)
Address offset: 0x2C
Reset value: 0x0000 FFFF
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:16] | |||
| rw | rw | rw | rw | ||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| ARR[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 31:20 Reserved, must be kept at reset value.
Bits 19:0 ARR[19:0]: Auto-reload value
ARR is the value to be loaded into the actual auto-reload register.
Refer to Section 33.3.4: Time-base unit for more details about ARR update and behavior.
The counter is blocked while the auto-reload value is null.
Non-dithering mode (DITHER = 0)
The register holds the auto-reload value in ARR[15:0]. The ARR[19:16] bits are reserved.
Dithering mode (DITHER = 1)
The register holds the integer part in ARR[19:4]. The ARR[3:0] bitfield contains the dithered part.
33.4.9 TIM6/TIM7 register map
TIM6/TIM7 registers are mapped as 16-bit addressable registers as described in the table below:
Table 333. TIM6/TIM7 register map and reset values
| Offset | Register name | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0x00 | TIM_CR1 | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | DITHEN | UIFREMA | Res. | Res. | Res. | ARPE | Res. | Res. | Res. | OPM | URS | UDIS | CEN | ||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||||||
| 0x04 | TIM_CR2 | Res. | Res. | Res. | ADSYNC | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | MMS [2:0] | Res. | Res. | Res. | Res. | Res. | |||||||||
| Reset value | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||||||||||||
| 0x08 | Reserved | Res. | |||||||||||||||||||||||||||||||||||||||
| 0x0C | TIM_DIER | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UDE | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIE | ||||||||
| Reset value | 0 | 0 | |||||||||||||||||||||||||||||||||||||||
| 0x10 | TIM_SR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIOVRF | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UIF | |||||||||
| Reset value | 0 | 0 | |||||||||||||||||||||||||||||||||||||||
| 0x14 | TIM_EGR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | UG | |||||||||
| Reset value | 0 | ||||||||||||||||||||||||||||||||||||||||
| 0x18-0x20 | Reserved | Res. | |||||||||||||||||||||||||||||||||||||||
| 0x24 | TIM_CNT | UIFCPY or Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | CNT[15:0] | ||||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||
| 0x28 | TIM_PSC | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | PSC[15:0] | |||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||||||
| 0x2C | TIM_ARR | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | ARR[19:0] | |||||||||||||||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||||||||||||||||||||
Refer to Section 2.2: Memory organization for the register boundary addresses.