17. General-purpose timers (TIM16)
Note: In this section, “TIMx” should be understood as “TIM16” since there is only one instance of this timer in STM32WL3Rxx devices.
17.1 TIM16 introduction
The TIM16 timer consists of a 16-bit auto-reload counter driven by a programmable prescaler.
It may be used for a variety of purposes, including measuring the pulse lengths of input signals (input capture) or generating output waveforms (output compare, PWM, complementary PWM with dead-time insertion).
Pulse lengths and waveform periods can be modulated from a few microseconds to several milliseconds using the timer prescaler and the RCC clock controller prescalers.
17.2 TIM16 main features
The TIM16 timer includes the following features:
- • 16-bit auto-reload upcounter
- • 16-bit programmable prescaler used to divide (also “on the fly”) the counter clock frequency by any factor between 1 and 65535
- • One channel for:
- – Input capture
- – Output compare
- – PWM generation (edge-aligned mode)
- – One-pulse mode output
- • Complementary output with programmable dead-time
- • Synchronization circuit to control the timer with external signals and to interconnect several timers together
- • Repetition counter to update the timer registers only after a given number of cycles of the counter
- • Break input to put the timer’s output signals in the reset state or a known state
- • Interrupt/DMA generation on the following events:
- – Update: counter overflow
- – Trigger event (counter start, stop, initialization or count by internal/external trigger)
- – Input capture
- – Output compare
- – Break input (interrupt request)
Figure 106. TIM16 block diagram

The diagram illustrates the internal architecture of the TIM16 timer. It features an internal clock (CK_INT) and an external clock (CK_TIM151617 from RCC). The trigger section includes a Trigger controller and a Slave controller mode, which receive inputs from ITR0 to ITR3 via an ITR multiplexer and TRC. The slave controller mode provides Reset, enable, and count control. The main timer section consists of a PSC prescaler, a CK_CNT counter, and a Capture/Compare 1 register. The PSC prescaler takes inputs from TIMx_CH1 (T1) and TRC, and its output CK_PSC feeds into the CK_CNT counter. The CK_CNT counter is controlled by the Auto-reload register and the REP register. The Capture/Compare 1 register is connected to the CK_CNT counter and the DTG registers. The DTG registers control the Output control block, which drives the TIMx_CH1 and TIMx_CH1N outputs. The TIMx_BKIN input is processed by a Polarity selection block and an OR gate with internal break event sources to produce the BI signal, which is then used by the Output control block. The diagram also shows various control signals like TRGO, TRGI, TGI, T1F_ED, T1FP1, U, UI, and OC1N.
Notes:
- Reg: Preload registers transferred to active registers on U event according to control bit
- →: Event
- ↗: Interrupt & DMA output
MSv58751V1
17.3 TIM16 functional description
17.3.1 Time-base unit
The main block of the programmable advanced-control timer is a 16-bit upcounter with its related auto-reload register. The counter clock can be divided by a prescaler.
The counter, the auto-reload register and the prescaler register can be written or read by software. This is true even when the counter is running.
The time-base unit includes:
- • Counter register (TIMx_CNT)
- • Prescaler register (TIMx_PSC)
- • Auto-reload register (TIMx_ARR)
- • Repetition counter register (TIMx_RCR)
The auto-reload register is preloaded. Writing to or reading from the auto-reload register accesses the preload register. The content of the preload register are transferred into the shadow register permanently or at each update event (UEV), depending on the auto-reload preload enable bit (ARPE) in TIMx_CR1 register. The update event is sent when the counter reaches the overflow and if the UDIS bit equals 0 in the TIMx_CR1 register. It can also be generated by software. The generation of the update event is described in detailed for each configuration.
The counter is clocked by the prescaler output CK_CNT, which is enabled only when the counter enable bit (CEN) in TIMx_CR1 register is set (refer also to the slave mode controller description to get more details on counter enabling).
Note that the counter starts counting 1 clock cycle after setting the CEN bit in the TIMx_CR1 register.
Prescaler description
The prescaler can divide the counter clock frequency by any factor between 1 and 65536. It is based on a 16-bit counter controlled through a 16-bit register (in the TIMx_PSC register). It can be changed on the fly as this control register is buffered. The new prescaler ratio is taken into account at the next update event.
Figure 107 and Figure 108 give some examples of the counter behavior when the prescaler ratio is changed on the fly:
Figure 107. Counter timing diagram with prescaler division change from 1 to 2

The diagram illustrates the timing sequence for changing the prescaler division from 1 to 2. The CK_PSC signal is a continuous high-frequency clock. The CEN signal is a low-to-high transition that enables the timer. The Timer clock = CK_CNT is derived from CK_PSC and is divided by the prescaler. The Counter register shows the count sequence: F7, F8, F9, FA, FB, FC, 00, 01, 02, 03. An Update event (UEV) occurs at the end of the counter rollover (FC to 00). The Prescaler control register is updated from 0 to 1. The Prescaler buffer also updates from 0 to 1. The Prescaler counter then increments from 0 to 1, 0 to 1, 0 to 1, 0 to 1, indicating a division by 2.
MS31076V2
Figure 108. Counter timing diagram with prescaler division change from 1 to 4

The diagram illustrates the timing sequence for changing the prescaler division from 1 to 4. The CK_PSC signal is a continuous high-frequency clock. The CEN signal is a low-to-high transition that enables the timer. The Timer clock = CK_CNT is derived from CK_PSC and is divided by the prescaler. The Counter register shows the count sequence: F7, F8, F9, FA, FB, FC, 00, 01. An Update event (UEV) occurs at the end of the counter rollover (FC to 00). The Prescaler control register is updated from 0 to 3. The Prescaler buffer also updates from 0 to 3. The Prescaler counter then increments from 0 to 1, 2, 3, 0 to 1, 2, 3, indicating a division by 4.
MS31077V2
17.3.2 Counter modes
Upcounting mode
In upcounting mode, the counter counts from 0 to the auto-reload value (content of the TIMx_ARR register), then restarts from 0 and generates a counter overflow event.
If the repetition counter is used, the update event (UEV) is generated after upcounting is repeated for the number of times programmed in the repetition counter register (TIMx_RCR). Else the update event is generated at each counter overflow.
Setting the UG bit in the TIMx_EGR register (by software or by using the slave mode controller) also generates an update event.
The UEV event can be disabled by software by setting the UDIS bit in the TIMx_CR1 register. This is to avoid updating the shadow registers while writing new values in the preload registers. Then no update event occurs until the UDIS bit has been written to 0. However, the counter restarts from 0, as well as the counter of the prescaler (but the prescale rate does not change). In addition, if the URS bit (update request selection) in TIMx_CR1 register is set, setting the UG bit generates an update event UEV but without setting the UIF flag (thus no interrupt or DMA request is sent). This is to avoid generating both update and capture interrupts when clearing the counter on the capture event.
When an update event occurs, all the registers are updated and the update flag (UIF bit in TIMx_SR register) is set (depending on the URS bit):
- • The repetition counter is reloaded with the content of TIMx_RCR register,
- • The auto-reload shadow register is updated with the preload value (TIMx_ARR),
- • The buffer of the prescaler is reloaded with the preload value (content of the TIMx_PSC register).
The following figures show some examples of the counter behavior for different clock frequencies when TIMx_ARR=0x36.
Figure 109. Counter timing diagram, internal clock divided by 1

The diagram illustrates the timing of various signals during an upcounting mode overflow event. The Counter register is shown as a 32-bit register (bits 31 to 00) that increments from 36 to 00. The Counter overflow signal is a pulse that occurs when the counter reaches 00. The Update event (UEV) is a pulse that occurs when the counter reaches 00. The Update interrupt flag (UIF) is a pulse that occurs when the counter reaches 00. The Counter overflow, UEV, and UIF signals are all synchronized with the Counter register overflow.
MS31078V2
Figure 110. Counter timing diagram, internal clock divided by 2

This timing diagram illustrates the operation of a counter when the internal clock is divided by 2. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then transitions to low. The Timer clock = CK_CNT is derived from CK_PSC and is shown as a square wave with a period twice that of CK_PSC. The Counter register shows the sequence of values: 0034, 0035, 0036, 0000, 0001, 0002, 0003. A Counter overflow occurs when the counter reaches 0036 and rolls over to 0000. This overflow event triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF).
MS31079V2
Figure 111. Counter timing diagram, internal clock divided by 4

This timing diagram illustrates the operation of a counter when the internal clock is divided by 4. The CK_PSC signal is a high-frequency square wave. The CNT_EN signal is a low-active enable signal that starts high and then transitions to low. The Timer clock = CK_CNT is derived from CK_PSC and is shown as a square wave with a period four times that of CK_PSC. The Counter register shows the sequence of values: 0035, 0036, 0000, 0001. A Counter overflow occurs when the counter reaches 0036 and rolls over to 0000. This overflow event triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF).
MS31080V2
Figure 112. Counter timing diagram, internal clock divided by N

This timing diagram illustrates the operation of a counter when the internal clock is divided by an arbitrary factor N. The CK_PSC signal is a high-frequency square wave. The Timer clock = CK_CNT is derived from CK_PSC and is shown as a square wave with a period N times that of CK_PSC. The Counter register shows the sequence of values: 1F, 20, 00. A Counter overflow occurs when the counter reaches 20 and rolls over to 00. This overflow event triggers an Update event (UEV), which in turn sets the Update interrupt flag (UIF).
MS31081V2
Figure 113. Counter timing diagram, update event when ARPE=0 (TIMx_ARR not preloaded)

Figure 114. Counter timing diagram, update event when ARPE=1 (TIMx_ARR preloaded)

17.3.3 Repetition counter
Section 17.3.1: Time-base unit describes how the update event (UEV) is generated with respect to the counter overflows. It is actually generated only when the repetition counter has reached zero. This can be useful when generating PWM signals.
This means that data are transferred from the preload registers to the shadow registers (TIMx_ARR auto-reload register, TIMx_PSC prescaler register, but also TIMx_CCRx capture/compare registers in compare mode) every N counter overflows, where N is the value in the TIMx_RCR repetition counter register.
The repetition counter is decremented at each counter overflow.
The repetition counter is an auto-reload type; the repetition rate is maintained as defined by the TIMx_RCR register value (refer to Figure 115). When the update event is generated by software (by setting the UG bit in TIMx_EGR register) or by hardware through the slave mode controller, it occurs immediately whatever the value of the repetition counter is and the repetition counter is reloaded with the content of the TIMx_RCR register.
Figure 115. Update rate examples depending on mode and TIMx_RCR register settings

The diagram illustrates the timing of Update Events (UEV) in Edge-aligned mode, Upcounting, for different TIMx_RCR settings. The counter (TIMx_CNT) is shown as a sawtooth waveform. Arrows indicate counter overflows. UEV events are marked with a specific symbol (a right-pointing arrow with a small triangle above it).
- TIMx_RCR = 0: UEV occurs at every counter overflow.
- TIMx_RCR = 1: UEV occurs every 2 overflows.
- TIMx_RCR = 2: UEV occurs every 3 overflows.
- TIMx_RCR = 3: UEV occurs every 4 overflows.
- TIMx_RCR = 3 and re-synchronization: A UEV is triggered by software (by SW), indicated by a vertical dashed line, which immediately reloads the repetition counter and generates an update event.
UEV Update Event: Preload registers transferred to active registers and update interrupt generated.
MS31084V2
17.3.4 Clock selection
The counter clock can be provided by the following clock sources:
- • Internal clock (CK_INT)
- • External clock mode1: external input pin (TIx)
Internal clock source (CK_INT)
The CEN (in the TIMx_CR1 register) and UG bits (in the TIMx_EGR register) are control bits and can be changed only by software (except UG which remains cleared automatically). As soon as the CEN bit is written to 1, the prescaler is clocked by the internal clock CK_INT.
Figure 116 shows the behavior of the control circuit and the upcounter in normal mode, without prescaler.
Figure 116. Control circuit in normal mode, internal clock divided by 1

The diagram shows the following signals over time:
- Internal clock: A continuous square wave.
- CEN=CNT_EN: A low-to-high transition that enables the counter.
- UG: A pulse that occurs after CEN is set high, indicating a counter update.
- CNT_INIT: A pulse that occurs after UG, initializing the counter.
- Counter clock = CK_CNT = CK_PSC: A square wave that starts after CEN is set high and is synchronized with the internal clock.
- Counter register: A register with bits 31 down to 00. Bits 00-07 are shown as a sequence of values (00, 01, 02, 03, 04, 05, 06, 07) that increment on each rising edge of the counter clock.
MS31085V2
External clock source mode 1
This mode is selected when SMS=111 in the TIMx_SMCR register. The counter can count at each rising or falling edge on a selected input.
Figure 117. TI1 external clock connection example

The diagram illustrates the signal path for an external clock on TI1:
- TI1 Input: The external signal enters through a Filter (configured by ICF[3:0] in TIMx_CCMR1) and an Edge Detector.
- Edge Detector: Outputs TI1F_Rising (logic 0) and TI1F_Falling (logic 1) to a multiplexer (CC1P in TIMx_CCER).
- Multiplexer: Selects between TI1F_Rising and TI1F_Falling based on the CC1P bit.
- TRGI: The selected edge signal is sent to the TRGI input of a multiplexer.
- SMCR Multiplexer: Selects between TRGI and CK_INT (internal clock) based on the TS[2:0] bits in the TIMx_SMCR register. The options are:
- 0xx: ITRx
- 100: TI1_ED
- 101: TI1FP1
- 110: Reserved
- 111: Reserved
- Mode Selection: The output of the SMCR multiplexer goes to a second multiplexer that selects between external clock mode 1 (TRGI) and internal clock mode (CK_INT) based on the SMS[2:0] bits in the TIMx_SMCR register.
- Output: The final output is CK_PSC, which clocks the prescaler.
For example, to configure the upcounter to count in response to a rising edge on the TI1 input, use the following procedure:
- 1. Select the proper TI1x source (internal or external) with the TI1SEL[3:0] bits in the TIMx_TISEL register.
- 2. Configure channel 1 to detect rising edges on the TI1 input by writing CC2S = '01' in the TIMx_CCMR1 register.
- 3. Configure the input filter duration by writing the IC1F[3:0] bits in the TIMx_CCMR1 register (if no filter is needed, keep IC1F=0000).
- 4. Select rising edge polarity by writing CC1P=0 and CC1NP=0 in the TIMx_CCER register.
- 5. Configure the timer in external clock mode 1 by writing SMS=111 in the TIMx_SMCR register.
- 6. Select TI1 as the trigger input source by writing TS=110 in the TIMx_SMCR register.
- 7. Enable the counter by writing CEN=1 in the TIMx_CR1 register.
Note: The capture prescaler is not used for triggering, so you don't need to configure it.
When a rising edge occurs on TI1, the counter counts once and the TIF flag is set.
The delay between the rising edge on TI1 and the actual clock of the counter is due to the resynchronization circuit on TI1 input.
Figure 118. Control circuit in external clock mode 1

The diagram illustrates the timing relationship between the TI1 input, the counter enable signal (CNT_EN), the counter clock (CK_CNT = CK_PSC), the counter register, and the TIF flag. The counter clock is a pulse that occurs on the rising edge of TI1. The counter register increments on each counter clock pulse. The TIF flag is set on the rising edge of the counter clock and cleared by writing TIF=0.
17.3.5 Capture/compare channels
Each Capture/Compare channel is built around a capture/compare register (including a shadow register), a input stage for capture (with digital filter, multiplexing and prescaler) and an output stage (with comparator and output control).
Figure 119 to Figure 121 give an overview of one Capture/Compare channel.
The input stage samples the corresponding TIx input to generate a filtered signal TIxF. Then, an edge detector with polarity selection generates a signal (TIxFPx) which can be used as trigger input by the slave mode controller or as the capture command. It is prescaled before the capture register (ICxPS).
Figure 119. Capture/compare channel (example: channel 1 input stage)

The output stage generates an intermediate waveform which is then used for reference:
OCxRef (active high). The polarity acts at the end of the chain.
Figure 120. Capture/compare channel 1 main circuit

Figure 121. Output stage of capture/compare channel (channel 1)
![Block diagram of the output stage of capture/compare channel 1. The diagram shows the flow from the Output mode controller (receiving CNT>CCR1 and CNT=CCR1) to the Output selector (receiving OC1REF and OCxREF(1)). The Output selector feeds into a Dead-time generator (receiving DTG[7:0]) and a multiplexer. The multiplexer selects between OC1_DT and OC1N_DT based on the CC1P bit in TIMx_CCER. The selected signal passes through an inverter and a multiplexer (controlled by CC1NE and CC1E) to an Output enable circuit, which produces the OC1 output. A similar path exists for the complementary channel OC1N, controlled by CC1NE, CC1E, and CC1NP bits. The TIMx_BDTR register provides MOE, OSSI, and OSSR control signals to the output enable circuits. The TIMx_CCMR1 register provides OC1CE and OC1M[3:0] control signals. The TIMx_CCER register provides CC1P, CC1NE, and CC1E control signals. The TIMx_BDTR register also provides DTG[7:0] control signals. The TIMx_CCMR1 register also provides OCxREF(1) control signals. The TIMx_CCER register also provides CC1NP control signals. The TIMx_BDTR register also provides MOE, OSSI, and OSSR control signals. The TIMx_CCMR1 register also provides OC1CE and OC1M[3:0] control signals. The TIMx_CCER register also provides CC1P, CC1NE, and CC1E control signals. The TIMx_BDTR register also provides DTG[7:0] control signals. The TIMx_CCMR1 register also provides OCxREF(1) control signals.](/RM0551-STM32WL3R/7d2489babb3bf789de160fddd90c535b_img.jpg)
1. OCxREF, where x is the rank of the complementary channel
The capture/compare block is made of one preload register and one shadow register. Write and read always access the preload register.
In capture mode, captures are actually done in the shadow register, which is copied into the preload register.
In compare mode, the content of the preload register is copied into the shadow register which is compared to the counter.
17.3.6 Input capture mode
In Input capture mode, the Capture/Compare Registers (TIMx_CCRx) are used to latch the value of the counter after a transition detected by the corresponding ICx signal. When a capture occurs, the corresponding CCXIF flag (TIMx_SR register) is set and an interrupt or a DMA request can be sent if they are enabled. If a capture occurs while the CCxIF flag was already high, then the over-capture flag CCxOF (TIMx_SR register) is set. CCxIF can be cleared by software by writing it to '0' or by reading the captured data stored in the TIMx_CCRx register. CCxOF is cleared when you write it to '0'.
The following example shows how to capture the counter value in TIMx_CCR1 when TI1 input rises. To do this, use the following procedure:
- 1. Select the active input: TIMx_CCR1 must be linked to the TI1 input, so write the CC1S bits to 01 in the TIMx_CCMR1 register. As soon as CC1S becomes different from 00, the channel is configured in input and the TIMx_CCR1 register becomes read-only.
- 2. Program the input filter duration you need with respect to the signal you connect to the timer (when the input is one of the TIx (ICxF bits in the TIMx_CCMRx register). Let's imagine that, when toggling, the input signal is not stable during at most 5 internal clock cycles. We must program a filter duration longer than these 5 clock cycles. We can validate a transition on TI1 when 8 consecutive samples with the new level have been
detected (sampled at \(f_{DTS}\) frequency). Then write IC1F bits to 0011 in the TIMx_CCMR1 register.
- 3. Select the edge of the active transition on the TI1 channel by writing CC1P bit to 0 in the TIMx_CCER register (rising edge in this case).
- 4. Program the input prescaler. In our example, we wish the capture to be performed at each valid transition, so the prescaler is disabled (write IC1PS bits to '00' in the TIMx_CCMR1 register).
- 5. Enable capture from the counter into the capture register by setting the CC1E bit in the TIMx_CCER register.
- 6. If needed, enable the related interrupt request by setting the CC1IE bit in the TIMx_DIER register, and/or the DMA request by setting the CC1DE bit in the TIMx_DIER register.
When an input capture occurs:
- • The TIMx_CCR1 register gets the value of the counter on the active transition.
- • CC1IF flag is set (interrupt flag). CC1OF is also set if at least two consecutive captures occurred whereas the flag was not cleared.
- • An interrupt is generated depending on the CC1IE bit.
- • A DMA request is generated depending on the CC1DE bit.
In order to handle the overcapture, it is recommended to read the data before the overcapture flag. This is to avoid missing an overcapture which could happen after reading the flag and before reading the data.
Note: IC interrupt and/or DMA requests can be generated by software by setting the corresponding CCxG bit in the TIMx_EGR register.
17.3.7 Forced output mode
In output mode (CCxS bits = 00 in the TIMx_CCMRx register), each output compare signal (OCxREF and then OCx/OCxN) can be forced to active or inactive level directly by software, independently of any comparison between the output compare register and the counter.
To force an output compare signal (OCXREF/OCx) to its active level, you just need to write 101 in the OCxM bits in the corresponding TIMx_CCMRx register. Thus OCXREF is forced high (OCxREF is always active high) and OCx get opposite value to CCxP polarity bit.
For example: CCxP=0 (OCx active high) => OCx is forced to high level.
The OCxREF signal can be forced low by writing the OCxM bits to 100 in the TIMx_CCMRx register.
Anyway, the comparison between the TIMx_CCRx shadow register and the counter is still performed and allows the flag to be set. Interrupt and DMA requests can be sent accordingly. This is described in the output compare mode section below.
17.3.8 Output compare mode
This function is used to control an output waveform or indicating when a period of time has elapsed.
When a match is found between the capture/compare register and the counter, the output compare function:
- • Assigns the corresponding output pin to a programmable value defined by the output compare mode (OCxM bits in the TIMx_CCMRx register) and the output polarity (CCxP bit in the TIMx_CCER register). The output pin can keep its level (OCxM=000), be set active (OCxM=001), be set inactive (OCxM=010) or can toggle (OCxM=011) on match.
- • Sets a flag in the interrupt status register (CCxIF bit in the TIMx_SR register).
- • Generates an interrupt if the corresponding interrupt mask is set (CCXIE bit in the TIMx_DIER register).
- • Sends a DMA request if the corresponding enable bit is set (CCxDE bit in the TIMx_DIER register, CCDS bit in the TIMx_CR2 register for the DMA request selection).
The TIMx_CCRx registers can be programmed with or without preload registers using the OCxPE bit in the TIMx_CCMRx register.
In output compare mode, the update event UEV has no effect on OCxREF and OCx output. The timing resolution is one count of the counter. Output compare mode can also be used to output a single pulse (in One-pulse mode).
Procedure:
- 1. Select the counter clock (internal, external, prescaler).
- 2. Write the desired data in the TIMx_ARR and TIMx_CCRx registers.
- 3. Set the CCxIE bit if an interrupt request is to be generated.
- 4. Select the output mode. For example:
- – Write OCxM = 011 to toggle OCx output pin when CNT matches CCRx
- – Write OCxPE = 0 to disable preload register
- – Write CCxP = 0 to select active high polarity
- – Write CCxE = 1 to enable the output
- 5. Enable the counter by setting the CEN bit in the TIMx_CR1 register.
The TIMx_CCRx register can be updated at any time by software to control the output waveform, provided that the preload register is not enabled (OCxPE='0', else TIMx_CCRx shadow register is updated only at the next update event UEV). An example is given in Figure 122.
Figure 122. Output compare mode, toggle on OC1

Write B201h in the CC1R register
TIM1_CNT 0039 003A 003B B200 B201
TIM1_CCR1 003A B201
oc1ref=OC1
Match detected on CCR1
Interrupt generated if enabled
MS31092V1
17.3.9 PWM mode
Pulse Width Modulation mode allows you to generate a signal with a frequency determined by the value of the TIMx_ARR register and a duty cycle determined by the value of the TIMx_CCRx register.
The PWM mode can be selected independently on each channel (one PWM per OCx output) by writing '110' (PWM mode 1) or '111' (PWM mode 2) in the OCxM bits in the TIMx_CCMRx register. You must enable the corresponding preload register by setting the OCxPE bit in the TIMx_CCMRx register, and eventually the auto-reload preload register (in upcounting or center-aligned modes) by setting the ARPE bit in the TIMx_CR1 register.
As the preload registers are transferred to the shadow registers only when an update event occurs, before starting the counter, you have to initialize all the registers by setting the UG bit in the TIMx_EGR register.
OCx polarity is software programmable using the CCxP bit in the TIMx_CCER register. It can be programmed as active high or active low. OCx output is enabled by a combination of the CCxE, CCxNE, MOE, OSSR and OSSR bits (TIMx_CCER and TIMx_BDTR registers). Refer to the TIMx_CCER register description for more details.
In PWM mode (1 or 2), TIMx_CNT and TIMx_CCRx are always compared to determine whether TIMx_CCRx ≤ TIMx_CNT or TIMx_CNT ≤ TIMx_CCRx (depending on the direction of the counter).
The TIM16 is capable of upcounting only. Refer to Upcounting mode.
In the following example, we consider PWM mode 1. The reference PWM signal OCxREF is high as long as TIMx_CNT < TIMx_CCRx else it becomes low. If the compare value in TIMx_CCRx is greater than the auto-reload value (in TIMx_ARR) then OCxREF is held at '1'. If the compare value is 0 then OCxRef is held at '0'. Figure 123 shows some edge-aligned PWM waveforms in an example where TIMx_ARR=8.
Figure 123. Edge-aligned PWM waveforms (ARR=8)

The diagram illustrates edge-aligned PWM waveforms for a timer with an auto-reload register (ARR) value of 8. The counter register counts from 0 to 11. The OCXREF signal is a periodic square wave. The CCxIF signal is a pulse at the start of each period. The CCRx=4 and CCRx=8 signals show PWM pulses starting at the rising edge of OCXREF. The CCRx>8 and CCRx=0 signals show no output.
MS31093V1
17.3.10 Complementary outputs and dead-time insertion
The TIM16 general-purpose timer can output one complementary signal and manage the switching-off and switching-on of the outputs.
This time is generally known as dead-time and you have to adjust it depending on the devices you have connected to the outputs and their characteristics (intrinsic delays of level-shifters, delays due to power switches...)
You can select the polarity of the outputs (main output OCx or complementary OCxN) independently for each output. This is done by writing to the CCxP and CCxNP bits in the TIMx_CCER register.
The complementary signals OCx and OCxN are activated by a combination of several control bits: the CCxE and CCxNE bits in the TIMx_CCER register and the MOE, OISx, OISxN, OSSR and OSSR bits in the TIMx_BDTR and TIMx_CR2 registers. Refer to Table 55 for more details. In particular, the dead-time is activated when switching to the idle state (MOE falling down to 0).
Dead-time insertion is enabled by setting both CCxE and CCxNE bits, and the MOE bit if the break circuit is present. There is one 10-bit dead-time generator for each channel. From a reference waveform OCxREF, it generates 2 outputs OCx and OCxN. If OCx and OCxN are active high:
- • The OCx output signal is the same as the reference signal except for the rising edge, which is delayed relative to the reference rising edge.
- • The OCxN output signal is the opposite of the reference signal except for the rising edge, which is delayed relative to the reference falling edge.
If the delay is greater than the width of the active output (OCx or OCxN) then the corresponding pulse is not generated.
The following figures show the relationships between the output signals of the dead-time generator and the reference signal OCxREF. (we suppose CCxP=0, CCxNP=0, MOE=1, CCxE=1 and CCxNE=1 in these examples)
Figure 124. Complementary output with dead-time insertion.

MS31095V1
Figure 125. Dead-time waveforms with delay greater than the negative pulse.

MS31096V1
Figure 126. Dead-time waveforms with delay greater than the positive pulse.

MS31097V1
The dead-time delay is the same for each of the channels and is programmable with the DTG bits in the TIMx_BDTR register. Refer to Section 17.4.14: TIM16 break and dead-time register (TIMx_BDTR) for delay calculation.
Re-directing OCxREF to OCx or OCxN
In output mode (forced, output compare or PWM), OCxREF can be re-directed to the OCx output or to OCxN output by configuring the CCxE and CCxNE bits in the TIMx_CCER register.
This allows you to send a specific waveform (such as PWM or static active level) on one output while the complementary remains at its inactive level. Other alternative possibilities are to have both outputs at inactive level or both outputs active and complementary with dead-time.
Note: When only OCxN is enabled (CCxE=0, CCxNE=1), it is not complemented and becomes active as soon as OCxREF is high. For example, if CCxNP=0 then OCxN=OCxRef. On the other hand, when both OCx and OCxN are enabled (CCxE=CCxNE=1) OCx becomes active when OCxREF is high whereas OCxN is complemented and becomes active when OCxREF is low.
17.3.11 Using the break function
The purpose of the break function is to protect power switches driven by PWM signals generated with the TIM16 timer. The two break inputs are usually connected to fault outputs of power stages and 3-phase inverters. When activated, the break circuitry shuts down the PWM outputs and forces them to a predefined safe state.
When using the break function, the output enable signals and inactive levels are modified according to additional control bits (MOE, OSSI and OSSR bits in the TIMx_BDTR register, OISx and OISxN bits in the TIMx_CR2 register). In any case, the OCx and OCxN outputs cannot be set both to active level at a given time. Refer to Table 55 for more details.
When exiting from reset, the break circuit is disabled and the MOE bit is low. You can enable the break function by setting the BKE bit in the TIMx_BDTR register. The break input polarity can be selected by configuring the BKP bit in the same register. BKE and BKP can be modified at the same time. When the BKE and BKP bits are written, a delay of 1 APB clock cycle is applied before the writing is effective. Consequently, it is necessary to wait 1 APB clock period to correctly read back the bit after the write operation.
Because MOE falling edge can be asynchronous, a resynchronization circuit has been inserted between the actual signal (acting on the outputs) and the synchronous control bit (accessed in the TIMx_BDTR register). It results in some delays between the asynchronous and the synchronous signals. In particular, if you write MOE to 1 whereas it was low, you must insert a delay (dummy instruction) before reading it correctly. This is because you write the asynchronous signal and read the synchronous signal.
The break is generated by the BRK inputs which has:
- • Programmable polarity (BKP bit in the TIMx_BDTR register)
- • Programmable enable bit (BKE bit in the TIMx_BDTR register)
- • Programmable filter (BKF[3:0] bits in the TIMx_BDTR register) to avoid spurious events.
Caution: An asynchronous (clockless) operation is only guaranteed when the programmable filter is disabled.
When a break occurs (selected level on the break input):
- • The MOE bit is cleared asynchronously, putting the outputs in inactive state, idle state or even releasing the control to the AFIO controller (selected by the OSSI bit). This feature functions even if the MCU oscillator is off.
- • Each output channel is driven with the level programmed in the OISx bit in the TIMx_CR2 register as soon as MOE=0. If OSSI=0, the timer releases the output control (taken over by the AFIO controller) else the enable output remains high.
- • When complementary outputs are used:
- – The outputs are first put in reset state inactive state (depending on the polarity). This is done asynchronously so that it works even if no clock is provided to the timer.
- – If the timer clock is still present, then the dead-time generator is reactivated in order to drive the outputs with the level programmed in the OISx and OISxN bits after a dead-time. Even in this case, OCx and OCxN cannot be driven to their
active level together. Note that because of the resynchronization on MOE, the dead-time duration is a bit longer than usual (around 2 ck_tim clock cycles).
- – If OSSI=0 then the timer releases the enable outputs (taken over by the AFIO controller which forces a Hi-Z state) else the enable outputs remain or become high as soon as one of the CCxE or CCxNE bits is high.
- • The break status flag (BIF bit in the TIMx_SR register) is set. An interrupt can be generated if the BIE bit in the TIMx_DIER register is set. A DMA request can be sent if the BDE bit in the TIMx_DIER register is set.
- • If the AOE bit in the TIMx_BDTR register is set, the MOE bit is automatically set again at the next update event UEV. This can be used to perform a regulation, for instance. Else, MOE remains low until you write it to '1' again. In this case, it can be used for security and you can connect the break input to an alarm from power drivers, thermal sensors or any security components.
Note: The break inputs is acting on level. Thus, the MOE cannot be set while the break input is active (neither automatically nor by software). In the meantime, the status flag BIF cannot be cleared.
The break can be generated by the BRK input which has a programmable polarity and an enable bit BKE in the TIMx_BDTR Register.
In addition to the break input and the output management, a write protection has been implemented inside the break circuit to safeguard the application. It allows you to freeze the configuration of several parameters (dead-time duration, OCx/OCxN polarities and state when disabled, OCxM configurations, break enable and polarity). You can choose from 3 levels of protection selected by the LOCK bits in the TIMx_BDTR register. Refer to TIM16 break and dead-time register (TIMx_BDTR). The LOCK bits can be written only once after an MCU reset.
The Figure 127 shows an example of behavior of the outputs in response to a break.
Figure 127. Output behavior in response to a break

The diagram illustrates the output behavior of a timer in response to a BREAK signal (MOE low). The signals shown are OCxREF and OCx. The configurations for OCx are as follows:
- OCxREF
- OCx (OCxN not implemented, CCxP=0, OISx=1)
- OCx (OCxN not implemented, CCxP=0, OISx=0)
- OCx (OCxN not implemented, CCxP=1, OISx=1)
- OCx (OCxN not implemented, CCxP=1, OISx=0)
- OCx and OCxN (CCxE=1, CCxP=0, OISx=0, CCxNE=1, CCxNP=0, OISxN=1) with delay periods indicated between transitions.
- OCx and OCxN (CCxE=1, CCxP=0, OISx=1, CCxNE=1, CCxNP=1, OISxN=1) with delay periods indicated.
- OCx and OCxN (CCxE=1, CCxP=0, OISx=0, CCxNE=0, CCxNP=0, OISxN=1) with a delay period indicated for OCxN.
- OCx and OCxN (CCxE=1, CCxP=0, OISx=1, CCxNE=0, CCxNP=0, OISxN=0) with a delay period indicated for OCxN.
- OCx and OCxN (CCxE=1, CCxP=0, CCxNE=0, CCxNP=0, OISx=OISxN=0 or OISx=OISxN=1)
MS31098V1
17.3.12 Bidirectional break inputs
The TIM16 is featuring bidirectional break I/Os, as represented on Figure 128.
They allow the following:
- • A board-level global break signal available for signaling faults to external MCUs or gate drivers, with a unique pin being both an input and an output status pin.
- • Internal break sources and multiple external open drain comparator outputs ORed together to trigger a unique break event, when multiple internal and external break sources must be merged.
The break input is configured in bidirectional mode using the BKBID bit in the TIMxBDTR register. The BKBID programming bit can be locked in read-only mode using the LOCK bits in the TIMxBDTR register (in LOCK level 1 or above).
The bidirectional mode requires the I/O to be configured in open-drain mode with active low polarity (using BKINP and BKP bits). Any break request coming from break inputs forces a low level on the break input to signal the fault event. The bidirectional mode is inhibited if the polarity bits are not correctly set (active high polarity), for safety purposes.
The break software event (BG) also causes the break I/O to be forced to '0' to indicate to the external components that the timer has entered in break state. However, this is valid only if the break is enabled (BKE = 1). When a software break event is generated with BKE = 0, the outputs are put in safe state and the break flag is set, but there is no effect on the break I/O.
A safe disarming mechanism prevents the system to be definitively locked-up (a low level on the break input triggers a break which enforces a low level on the same input).
When the BKDSRM bit is set to 1, this releases the break output to clear a fault signal and to give the possibility to re-arm the system.
At no point the break protection circuitry can be disabled:
- • The break input path is always active: a break event is active even if the BKDSRM bit is set and the open drain control is released. This prevents the PWM output to be re-started as long as the break condition is present.
- • The BKDSRM bit cannot disarm the break protection as long as the outputs are enabled (MOE bit is set) (see Table 53)
Table 53. Break protection disarming conditions
| MODE | BKDIR | BKDSRM | Break protection state |
|---|---|---|---|
| 0 | 0 | X | Armed |
| 0 | 1 | 0 | Armed |
| 0 | 1 | 1 | Disarmed |
| 1 | X | X | Armed |
Arming and re-arming break circuitry
The break circuitry (in input or bidirectional mode) is armed by default (peripheral reset configuration).
The following procedure must be followed to re-arm the protection after a break event:
- • The BKDSRM bit must be set to release the output control
- • The software must poll the BKDSRM bit until it is cleared by hardware (when the application break condition disappears)
From this point, the break circuitry is armed and active, and the MOE bit can be set to re-enable the PWM outputs.
Figure 128. Output redirection

The diagram illustrates the logic for output redirection in a microcontroller's break circuitry. It shows the following components and signal paths:
- Inputs:
- Other break inputs: Feed into an OR gate.
- Bidirectional Break I/O: Connected to an AF input (active low) buffer and an AF output (open drain) driver.
- System break request: A high-level input that sets the SBIF flag and feeds into the bidirectional mode control logic.
- Software break requests: BG: A high-level input that feeds into a BKE gate.
- AF controller: Receives inputs from the AF input buffer and 'Other break inputs'. It outputs 'BKIN inputs from AF controller' to an OR gate.
- OR Gate: Combines 'Other break inputs' and 'BKIN inputs from AF controller'. Its output passes through a BKP (break point) flip-flop to become 'Application break requests'.
- Logic Gates: The 'Application break requests' signal is processed through a series of gates (AND, OR, and another AND) involving the BKE signal to generate the final BRK request.
- Bidirectional mode control logic: This block receives 'System break request' and 'BRK request' as inputs. It controls three output signals: MOE (Main Output Enable), BKBID (Break Bidirectional), and BKDSRM (Break Disable Software Reset Mask).
17.3.13 One-pulse mode
One-pulse mode (OPM) is a particular case of the previous modes. It allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length after a programmable delay.
Generating the waveform can be done in output compare mode or PWM mode. You select One-pulse mode by setting the OPM bit in the TIMx_CR1 register. This makes the counter stop automatically at the next update event UEV.
A pulse can be correctly generated only if the compare value is different from the counter initial value. Before starting, the configuration must be:
- • CNT < CCRx ≤ ARR (in particular, 0 < CCRx)
Figure 129. Example of one pulse mode.

The diagram illustrates the timing of One-pulse mode. It shows four signals over time (t):
- TI1: A trigger signal that starts the counter.
- OC1REF: A reference signal that is high during the pulse generation period.
- OC1: The output signal that follows OC1REF during the pulse generation period.
- Counter: A staircase signal that increments from 0 to TIM1_ARR. It starts at 0 and increments by 1 for each clock cycle. The counter value is compared to TIM1_CCR1. When the counter reaches TIM1_CCR1, a compare match occurs, and the output transitions from '0' to '1'. The counter continues to increment until it reaches TIM1_ARR, at which point it stops.
Key time intervals are marked:
- t_DELAY: The time interval from the start of the counter (triggered by TI1) to the compare match at TIM1_CCR1.
- t_PULSE: The time interval from the compare match at TIM1_CCR1 to the end of the counter at TIM1_ARR.
For example you may want to generate a positive pulse on OC1 with a length of \(t_{PULSE}\) and after a delay of \(t_{DELAY}\).
The OPM waveform is defined by writing the compare registers (taking into account the clock frequency and the counter prescaler).
- • The \(t_{DELAY}\) is defined by the value written in the TIMx_CCR1 register.
- • The \(t_{PULSE}\) is defined by the difference between the auto-reload value and the compare value (TIMx_ARR-TIMx_CCR1).
- • Let's say you want to build a waveform with a transition from '0' to '1' when a compare match occurs and a transition from '1' to '0' when the counter reaches the auto-reload value. To do this you enable PWM mode 2 by writing OC1M=111 in the TIMx_CCMR1 register. You can optionally enable the preload registers by writing OC1PE='1' in the TIMx_CCMR1 register and ARPE in the TIMx_CR1 register. In this case you have to write the compare value in the TIMx_CCR1 register, the auto-reload value in the TIMx_ARR register, generate an update by setting the UG bit and wait for external trigger event on TI1. CC1P is written to '0' in this example.
You only want 1 pulse, so you write '1' in the OPM bit in the TIMx_CR1 register to stop the counter at the next update event (when the counter rolls over from the auto-reload value back to 0).
Particular case: OCx fast enable
In One-pulse mode, the edge detection on TIx input set the CEN bit which enables the counter. Then the comparison between the counter and the compare value makes the output toggle. But several clock cycles are needed for these operations and it limits the minimum delay \(t_{DELAY\ min}\) we can get.
If you want to output a waveform with the minimum delay, you can set the OCxFE bit in the TIMx_CCMRx register. Then OCxRef (and OCx) are forced in response to the stimulus, without taking in account the comparison. Its new level is the same as if a compare match had occurred. OCxFE acts only if the channel is configured in PWM1 or PWM2 mode.
17.3.14 Retriggerable one pulse mode (OPM)
This mode allows the counter to be started in response to a stimulus and to generate a pulse with a programmable length, but with the following differences with Non-retriggerable one pulse mode described in Section 17.3.13: One-pulse mode:
- – The pulse starts as soon as the trigger occurs (no programmable delay)
- – The pulse is extended if a new trigger occurs before the previous one is completed
The timer must be in Slave mode, with the bits SMS[3:0] = ‘1000’ (Combined Reset + trigger mode) in the TIMx_SMCR register, and the OCxM[3:0] bits set to ‘1000’ or ‘1001’ for Retriggerable OPM mode 1 or 2.
If the timer is configured in Up-counting mode, the corresponding CCRx must be set to 0 (the ARR register sets the pulse length). If the timer is configured in Down-counting mode, CCRx must be above or equal to ARR.
Note: In retriggerable one pulse mode, the CCxIF flag is not significant. The OCxM[3:0] and SMS[3:0] bit fields are split into two parts for compatibility reasons, the most significant bit is not contiguous with the 3 least significant ones. This mode must not be used with center-aligned PWM modes. It is mandatory to have CMS[1:0] = 00 in TIMx_CR1
Figure 130. Retriggerable one pulse mode

The figure is a timing diagram illustrating the retriggerable one-pulse mode (OPM). It consists of three horizontal axes: TRGI (Trigger Generator Input), Counter, and Output.
- TRGI: Shows three positive pulses. The first pulse starts the counter ramp. The second pulse occurs while the counter is still ramping, which extends the output pulse. The third pulse occurs after the counter has finished its ramp and reset, starting a new output pulse.
- Counter: Shows a sawtooth-like ramp starting from zero at the beginning of each output pulse. The ramp duration is determined by the ARR register. If a new TRGI pulse occurs before the counter reaches its maximum, the ramp is extended.
- Output: Shows a pulse that is high while the counter is ramping and low otherwise. The output pulse is extended by the second TRGI pulse.
17.3.15 UIF bit remapping
The IUFREMAP bit in the TIMx_CR1 register forces a continuous copy of the Update Interrupt Flag UIF into bit 31 of the timer counter register (TIMxCNT[31]). This allows to atomically read both the counter value and a potential roll-over condition signaled by the UIFCPY flag. In particular cases, it can ease the calculations by avoiding race conditions caused for instance by a processing shared between a background task (counter reading) and an interrupt (Update Interrupt).
There is no latency between the assertions of the UIF and UIFCPY flags.
17.3.16 Timer16 and external trigger synchronization
The TIM16 Timer can be synchronized with an external trigger in several modes: Reset mode, Gated mode and Trigger mode.
Slave mode: Reset mode
The counter and its prescaler can be reinitialized in response to an event on a trigger input. Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated. In the following example, the upcounter is cleared in response to a rising edge on TI1 input:
- 1. Configure the channel 1 to detect rising edges on TI1. Configure the input filter duration (in this example, we do not need any filter, so we keep IC1F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. The CC1S bits select the input capture source only, CC1S = 01 in the TIMx_CCMR1 register. Write CC1P=0 and CC1NP=0 in TIMx_CCER register to validate the polarity (and detect rising edges only).
- 2. Configure the timer in reset mode by writing SMS=100 in TIMx_SMCR register. Select TI1 as the input source by writing TS=00101 in TIMx_SMCR register.
- 3. Start the counter by writing CEN=1 in the TIMx_CR1 register.
The counter starts counting on the internal clock, then behaves normally until TI1 rising edge. When TI1 rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (TIF bit in the TIMx_SR register) and an interrupt request can be sent if enabled (depending on the TIE bit in TIMx_DIER register).
The following figure shows this behavior when the auto-reload register TIMx_ARR=0x36. The delay between the rising edge on TI1 and the actual reset of the counter is due to the resynchronization circuit on TI1 input.
Figure 131. Control circuit in reset mode

Slave mode: Gated mode
The counter can be enabled depending on the level of a selected input.
In the following example, the upcounter counts only when TI1 input is low:
- 1. Configure the channel 1 to detect low levels on TI1. Configure the input filter duration (in this example, we do not need any filter, so we keep IC1F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. The CC1S bits select the input capture source only, CC1S=01 in TIMx_CCMR1 register. Write CC1P=1 and CC1NP=0 in TIMx_CCER register to validate the polarity (and detect low level only).
- 2. Configure the timer in gated mode by writing SMS=101 in TIMx_SMCR register. Select TI1 as the input source by writing TS=00101 in TIMx_SMCR register.
- 3. Enable the counter by writing CEN=1 in the TIMx_CR1 register (in gated mode, the counter doesn't start if CEN=0, whatever is the trigger input level).
The counter starts counting on the internal clock as long as TI1 is low and stops as soon as TI1 becomes high. The TIF flag in the TIMx_SR register is set both when the counter starts or stops.
The delay between the rising edge on TI1 and the actual stop of the counter is due to the resynchronization circuit on TI1 input.
Figure 132. Control circuit in gated mode

- 1. The configuration "CCxP=CCxNP=1" (detection of both rising and falling edges) does not have any effect in gated mode because gated mode acts on a level and not on an edge.
Note: The configuration “CCxP=CCxNP=1” (detection of both rising and falling edges) does not have any effect in gated mode because gated mode acts on a level and not on an edge.
Slave mode: Trigger mode
The counter can start in response to an event on a selected input.
In the following example, the upcounter starts in response to a rising edge on TI2 input:
- 1. Configure the channel 2 to detect rising edges on TI2. Configure the input filter duration (in this example, we do not need any filter, so we keep IC2F=0000). The capture prescaler is not used for triggering, so it does not need to be configured. CC2S bits are selecting the input capture source only, CC2S=01 in TIMx_CCMR1 register. Write CC2P=1 and CC2NP=0 in TIMx_CCER register to validate the polarity (and detect low level only). 2. Configure the timer in trigger mode by writing SMS=110 in TIMx_SMCR register. Select TI2 as the input source by writing TS=00110 in TIMx_SMCR register.
When a rising edge occurs on TI2, the counter starts counting on the internal clock and the TIF flag is set.
The delay between the rising edge on TI2 and the actual start of the counter is due to the resynchronization circuit on TI2 input.
Figure 133. Control circuit in trigger mode

Slave mode – combined reset + trigger mode
In this case, a rising edge of the selected trigger input (TRGI) reinitializes the counter, generates an update of the registers, and starts the counter. This mode is used for one-pulse mode.
17.3.17 Timer synchronization
The TIMx timers are linked together internally for timer synchronization or chaining. When one Timer is configured in Master Mode, it can reset, start, stop or clock the counter of another Timer configured in Slave Mode.
Figure 134 presents an overview of the trigger selection and the master mode selection blocks.
Figure 134. Master/slave timers example

The diagram illustrates the connection between two timers, TIM16 and TIM2, in a master-slave configuration. TIM16 (Master): A Clock signal enters a Prescaler block, which connects to a Counter block. The Counter outputs an Update Event (UEV) to the Master mode control block. The Master mode control block has an MMS input and a TRGO output. TIM2 (Slave): The TRGO output from TIM16 connects to the ITR0 input of an Input trigger selection block. This block has a TS input and connects to the Slave mode control block. The Slave mode control block has an SMS input and a CK_PSC output. The CK_PSC output connects to a Prescaler block, which then connects to a Counter block.
Using one timer as prescaler for another timer
For example, TIM16 can be configured to act as a prescaler for TIM2. Refer to Figure 134. To do this:
- 1. Configure TIM16 in master mode so that it outputs a periodic trigger signal on each update event UEV. If MMS=010 is written in the TIM16_CR2 register, a rising edge is output on TRGO each time an update event is generated.
- 2. To connect the TRGO output of TIM16 to TIM2, TIM2 must be configured in slave mode using ITR0 as internal trigger. This is selected through the TS bits in the TIM2_SMCR register (writing TS=00000).
- 3. Then the slave mode controller must be put in external clock mode 1 (write SMS=111 in the TIM2_SMCR register). This causes TIM2 to be clocked by the rising edge of the periodic TIM16 trigger signal (which correspond to the TIM16 counter overflow).
- 4. Finally both timers must be enabled by setting their respective CEN bits (TIMx_CR1 register).
Note: If OCx is selected on TIM16 as the trigger output (MMS=1xx), its rising edge is used to clock the counter of TIM2.
Using one timer to enable another timer
In this example, we control the enable of TIM2 with the output compare 1 of Timer 2. Refer to Figure 134 for connections. TIM2 counts on the divided internal clock only when OC1REF of TIM16 is high. Both counter clock frequencies are divided by 3 by the prescaler compared to CK_INT (\(f_{CK\_CNT} = f_{CK\_INT}/3\)).
- 1. Configure TIM16 master mode to send its Output Compare 1 Reference (OC1REF) signal as trigger output (MMS=100 in the TIM16_CR2 register).
- 2. Configure the TIM16 OC1REF waveform (TIM16_CCMR1 register).
- 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
- 4. Configure TIM2 in gated mode (SMS=101 in TIM2_SMCR register).
- 5. Enable TIM2 by writing '1' in the CEN bit (TIM2_CR1 register).
- 6. Start TIM16 by writing '1' in the CEN bit (TIM16_CR1 register).
Note: The counter 2 clock is not synchronized with counter 1, this mode only affects the TIM16 counter enable signal.
Figure 135. Gating TIM2 with OC1REF of TIM16

The diagram illustrates the gating of TIM2 by TIM16-OC1REF. The CK_INT signal is a continuous clock. The TIM16-OC1REF signal is a pulse that gates the TIM2 counter. The TIM16-CNT signal shows the count sequence: FC, FD, FE, FF, 00, 01. The TIM2-CNT signal shows the count sequence: 3045, 3046, 3047, 3048. The TIM2-TIF signal is high when TIM16-OC1REF is high and TIM2-CNT is at 3046. An arrow labeled 'Write TIF=0' points to the transition of TIM2-TIF from high to low.
In the example in Figure 135, the TIM2 counter and prescaler are not initialized before being started. So they start counting from their current value. It is possible to start from a given value by resetting both timers before starting TIM16. Then any value can be written in the timer counters. The timers can easily be reset by software using the UG bit in the TIMx_EGR registers.
In the next example (refer to Figure 136), we synchronize TIM16 and TIM2. TIM16 is the master and starts from 0. TIM2 is the slave and starts from 0xE7. The prescaler ratio is the same for both timers. TIM2 stops when TIM16 is disabled by writing '0 to the CEN bit in the TIM16_CR1 register:
- 1. Configure TIM16 master mode to send its Output Compare 1 Reference (OC1REF) signal as trigger output (MMS=100 in the TIM16_CR2 register).
- 2. Configure the TIM16 OC1REF waveform (TIM16_CCMR1 register).
- 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
- 4. Configure TIM2 in gated mode (SMS=101 in TIM2_SMCR register).
- 5. Reset TIM16 by writing '1 in UG bit (TIM16_EGR register).
- 6. Reset TIM2 by writing '1 in UG bit (TIM2_EGR register).
- 7. Initialize TIM2 to 0xE7 by writing '0xE7' in the TIM2 counter (TIM2_CNTL).
- 8. Enable TIM2 by writing '1 in the CEN bit (TIM2_CR1 register).
- 9. Start TIM16 by writing '1 in the CEN bit (TIM16_CR1 register).
- 10. Stop TIM16 by writing '0 in the CEN bit (TIM16_CR1 register).
Figure 136. Gating TIM2 with Enable of TIM16

The diagram illustrates the timing relationship between TIM16 and TIM2. CK_INT is a continuous clock. TIM16-CEN=CNT_EN is a high signal that enables TIM16. TIM16-CNT_INIT is a low pulse that initializes TIM16. TIM16-CNT shows the counter values: 75, 00, 01, 02. TIM2-CNT shows the counter values: AB, 00, E7, E8, E9. TIM2-CNT_INIT is a low pulse that initializes TIM2. TIM2 (write CNT) is a low pulse that writes the counter value. TIM2-TIF is a low pulse that indicates a trigger flag. An arrow labeled 'Write TIF=0' points to the TIM2-TIF signal.
Using one timer to start another timer
In this example, we set the enable of Timer 2 with the update event of Timer 16. Refer to Figure 134 for connections. Timer 2 starts counting from its current value (which can be non-zero) on the divided internal clock as soon as the update event is generated by Timer 16.
When Timer 2 receives the trigger signal its CEN bit is automatically set and the counter counts until we write '0 to the CEN bit in the TIM2_CR1 register. Both counter clock frequencies are divided by 3 by the prescaler compared to CK_INT (\(f_{CK\_CNT} = f_{CK\_INT}/3\)).
- 1. Configure TIM16 master mode to send its Update Event (UEV) as trigger output (MMS=010 in the TIM16_CR2 register).
- 2. Configure the TIM16 period (TIM16_ARR registers).
- 3. Configure TIM2 to get the input trigger from TIM16 (TS=00000 in the TIM2_SMCR register).
- 4. Configure TIM2 in trigger mode (SMS=110 in TIM2_SMCR register).
- 5. Start TIM16 by writing '1 in the CEN bit (TIM16_CR1 register).
Figure 137. Triggering TIM2 with update of TIM16

The diagram illustrates the timing relationship between TIM16 and TIM2. CK_INT is a continuous clock. TIM16-UEV is a low pulse that triggers TIM2. TIM16-CNT shows the counter values: FD, FE, FF, 00, 01, 02. TIM2-CNT shows the counter values: 45, 46, 47, 48. TIM2-CEN=CNT_EN is a low pulse that enables TIM2. TIM2-TIF is a low pulse that indicates a trigger flag. An arrow labeled 'Write TIF=0' points to the TIM2-TIF signal.
As in the previous example, both counters can be initialized before starting counting.
Figure 138 shows the behavior with the same configuration as in Figure 137 but in trigger mode instead of gated mode (SMS=110 in the TIM2_SMCR register).
Figure 138. Triggering TIM2 with Enable of TIM16

The diagram illustrates the timing relationship between TIM16 and TIM2. CK_INT provides a constant clock. TIM16-CEN=CNT_EN enables TIM16. TIM16-CNT_INIT initializes TIM16. TIM16-CNT shows a sequence of values: 75, 00, 01, 02. TIM2-CNT shows a sequence of values: CD, 00, E7, E8, E9, EA. TIM2-CNT_INIT initializes TIM2. TIM2 write CNT is a pulse. TIM2-TIF is a pulse that is cleared by writing TIF=0.
Note: The clock of the slave peripherals (timer and so on) receiving the TRGO signal must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.
17.3.18 DMA burst mode
The TIMx timers have the capability to generate multiple DMA requests on a single event. The main purpose is to be able to re-program several timer registers multiple times without software overhead, but it can also be used to read several registers in a row, at regular intervals.
The DMA controller destination is unique and must point to the virtual register TIMx_DMAR. On a given timer event, the timer launches a sequence of DMA requests (burst). Each write into the TIMx_DMAR register is actually redirected to one of the timer registers.
The DBL[4:0] bits in the TIMx_DCR register set the DMA burst length. The timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address, i.e. the number of transfers (either in half-words or in bytes).
The DBA[4:0] bits in the TIMx_DCR registers define the DMA base address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.
Example:
00000: TIMx_CR1,
00001: TIMx_CR2,
For example, the timer DMA burst feature could be used to update the contents of the CCRx registers (x = 2, 3, 4) on an update event, with the DMA transferring half words into the CCRx registers.
This is done in the following steps:
- 1. Configure the corresponding DMA channel as follows:
- – DMA channel peripheral address is the DMAR register address
- – DMA channel memory address is the address of the buffer in the RAM containing the data to be transferred by DMA into the CCRx registers.
- – Number of data to transfer = 3 (See note below).
- – Circular mode disabled.
- 2. Configure the DCR register by configuring the DBA and DBL bit fields as follows:
DBL = 3 transfers, DBA = 0xE. - 3. Enable the TIMx update DMA request (set the UDE bit in the DIER register).
- 4. Enable TIMx
- 5. Enable the DMA channel
This example is for the case where every CCRx register is to be updated once. If every CCRx register is to be updated twice for example, the number of data to transfer should be 6. Let's take the example of a buffer in the RAM containing data1, data2, data3, data4, data5 and data6. The data is transferred to the CCRx registers as follows: on the first update DMA request, data1 is transferred to CCR2, data2 is transferred to CCR3, data3 is transferred to CCR4 and on the second update DMA request, data4 is transferred to CCR2, data5 is transferred to CCR3 and data6 is transferred to CCR4.
17.3.19 Debug mode
When the system enters debug mode (processor core halted), the TIMx counter either continues to work normally or stops, depending on DBG_TIM16_STOP configuration bit in DBGMCU module. For more details, refer to Section 25.3.2: DBG APB0 freeze register (DBG_APB0_FZ).
17.4 TIM16 registers
Refer to Section 1.1: List of abbreviations for registers for a list of abbreviations used in register descriptions.
17.4.1 TIM16 control register 1 (TIMx_CR1)
Address offset: 0x00
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | UIF REM- AP | Res | CKD[1:0] | ARPE | Res | Res | Res | OPM | URS | UDIS | CEN | |
| rw | rw | rw | rw | rw | rw | rw | rw | ||||||||
Bits 15:12 Reserved, must be kept at reset value.
Bit 11 UIFREMAP: UIF status bit remapping
0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.
Bit 10 Reserved, must be kept at reset value.
Bits 9:8 CKD[1:0]: Clock division
This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the dead-time and sampling clock (\(t_{DTS}\)) used by the dead-time generators and the digital filters (TIx),
00: \(t_{DTS}=t_{CK\_INT}\)
01: \(t_{DTS}=2*t_{CK\_INT}\)
10: \(t_{DTS}=4*t_{CK\_INT}\)
11: Reserved, do not program this value
Bit 7 ARPE: Auto-reload preload enable
0: TIMx_ARR register is not buffered
1: TIMx_ARR register is buffered
Bits 6:4 Reserved, must be kept at reset value.
Bit 3 OPM: One pulse mode
0: Counter is not stopped at update event
1: Counter stops counting at the next update event (clearing the bit CEN)
Bit 2 URS: Update request source
This bit is set and cleared by software to select the UEV event sources.
0: Any of the following events generate an update interrupt or DMA request if enabled.
These events can be:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.
Bit 1 UDIS: Update disable
This bit is set and cleared by software to enable/disable UEV event generation.
0: UEV enabled. The Update (UEV) event is generated by one of the following events:
- - Counter overflow/underflow
- - Setting the UG bit
- - Update generation through the slave mode controller
Buffered registers are then loaded with their preload values.
1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR, PSC, CCRx). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware reset is received from the slave mode controller.
Bit 0 CEN: Counter enable
0: Counter disabled
1: Counter enabled
Note: External clock and gated mode can work only if the CEN bit has been previously set by software. However trigger mode can set the CEN bit automatically by hardware.
17.4.2 TIM16 control register 2 (TIMx_CR2)
Address offset: 0x04
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | OIS1N | OIS1 | TI1S | MMS[2:0] | CCDS | CCUS | Res | CCPC | ||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | |||||||
Bits 15:10 Reserved, must be kept at reset value.
Bit 9 OIS1N: Output Idle state 1 (OC1N output)
0: OC1N=0 after a dead-time when MOE=0
1: OC1N=1 after a dead-time when MOE=0
Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BKR register).
Bit 8 OIS1: Output Idle state 1 (OC1 output)
0: OC1=0 (after a dead-time if OC1N is implemented) when MOE=0
1: OC1=1 (after a dead-time if OC1N is implemented) when MOE=0
Note: This bit can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BKR register).
Bit 7 TI1S: TI1 selection
0: The TIMx_CH1 pin is connected to TI1 input
1: Reserved
Bits 6:4 MMS[2:0]: Master mode selection
These bits allow to select the information to be sent in master mode to slave timers for synchronization (TRGO). The combination is as follows:
000: Reset - the UG bit from the TIMx_EGR register is used as trigger output (TRGO). If the reset is generated by the trigger input (slave mode controller configured in reset mode) then the signal on TRGO is delayed compared to the actual reset.
001: Enable - the Counter Enable signal CNT_EN is used as trigger output (TRGO). It is useful to start several timers at the same time or to control a window in which a slave timer is enable. The Counter Enable signal is generated by a logic OR between CEN control bit and the trigger input when configured in gated mode. When the Counter Enable signal is controlled by the trigger input, there is a delay on TRGO, except if the master/slave mode is selected (see the MSM bit description in TIMx_SMCR register).
010: Update - The update event is selected as trigger output (TRGO). For instance a master timer can then be used as a prescaler for a slave timer.
011: Compare Pulse - The trigger output send a positive pulse when the CC1IF flag is to be set (even if it was already high), as soon as a capture or a compare match occurred. (TRGO).
100: Compare - OC1REF signal is used as trigger output (TRGO).
Bit 3 CCDS: Capture/compare DMA selection
0: CCx DMA request sent when CCx event occurs
1: CCx DMA requests sent when update event occurs
Bit 2 CCUS: Capture/compare control update selection
0: When capture/compare control bits are preloaded (CCPC=1), they are updated by setting the COMG bit only.
1: When capture/compare control bits are preloaded (CCPC=1), they are updated by setting the COMG bit or when an rising edge occurs on TRGI.
Note: This bit acts only on channels that have a complementary output.
Bit 1 Reserved, must be kept at reset value.
Bit 0 CCPC: Capture/compare preloaded control
0: CCxE, CCxNE and OCxM bits are not preloaded
1: CCxE, CCxNE and OCxM bits are preloaded, after having been written, they are updated only when COM bit is set.
Note: This bit acts only on channels that have a complementary output.
17.4.3 TIM16 slave mode control register (TIM16_SMCR)
Address offset: 0x08
Reset value: 0x0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | TS[4:3] | Res. | Res. | Res. | SMS[3] | |
| rw | rw | rw | |||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| MSM | TS[2:0] | Res. | SMS[2:0] | ||||||||||||
| rw | rw | rw | rw | rw | rw | rw | |||||||||
Bit 31:22 Reserved, must be kept at reset value.
Bit 19:18 Reserved, must be kept at reset value.
Bit 7 MSM: Master/slave mode
0: No action
1: The effect of an event on the trigger input (TRGI) is delayed to allow a perfect synchronization between the current timer and its slaves (through TRGO). It is useful if we want to synchronize several timers on a single external event.
Bits 21,20, 6:4 TS[4:0]: Trigger selection
This bitfield selects the trigger input to be used to synchronize the counter.
00000: Internal Trigger 0 (ITR0)
00001: Internal Trigger 1 (ITR1)
00010: Internal Trigger 2 (ITR2)
00011: Internal Trigger 3 (ITR3)
00100: TI1 Edge Detector (TI1F_ED)
00101: Filtered Timer Input 1 (TI1FP1)
Other codes: Reserved
Note: These bits must be changed only when they are not used (e.g. when SMS=000) to avoid wrong edge detections at the transition.
See Table 56: TIM16 register map and reset values for more details on ITRx meaning for each Timer.
Bit 3 Reserved, must be kept at reset value.
Bits16, 2:0 SMS[3:0]: Slave mode selection
When external signals are selected the active edge of the trigger signal (TRGI) is linked to the polarity selected on the external input (see Input Control register and Control Register description).
0000: Slave mode disabled - if CEN = '1' then the prescaler is clocked directly by the internal clock.
0100: Reset Mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter and generates an update of the registers.
0101: Gated Mode - The counter clock is enabled when the trigger input (TRGI) is high. The counter stops (but is not reset) as soon as the trigger becomes low. Both start and stop of the counter are controlled.
0110: Trigger Mode - The counter starts at a rising edge of the trigger TRGI (but it is not reset). Only the start of the counter is controlled.
0111: External Clock Mode 1 - Rising edges of the selected trigger (TRGI) clock the counter.
1000: Combined reset + trigger mode - Rising edge of the selected trigger input (TRGI) reinitializes the counter, generates an update of the registers and starts the counter.
Other codes: Reserved
Note: The gated mode must not be used if TI1F_ED is selected as the trigger input (TS='00100'). Indeed, TI1F_ED outputs 1 pulse for each transition on TI1F, whereas the gated mode checks the level of the trigger signal.
Note: The clock of the slave peripherals (timer16) receiving the TRGO signal must be enabled prior to receive events from the master timer, and the clock frequency (prescaler) must not be changed on-the-fly while triggers are received from the master timer.
Table 54. TIM16 internal trigger connection
| Slave TIM | ITR0 | ITR1 | ITR2 - ITR8 |
|---|---|---|---|
| TIM16 | TIM2 | - | - |
17.4.4 TIM16 DMA/interrupt enable register (TIMx_DIER)
Address offset: 0x0C
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | TDE | Res | Res | Res | Res | CC1DE | UDE | BIE | TIE | COMIE | Res | Res | Res | CC1IE | UIE |
| rw | rw | rw | rw | rw | rw | rw | rw |
Bit 15:13 Reserved, must be kept at reset value.
Bit 14 TDE: Trigger DMA request enable
0: Trigger DMA request disabled
1: Trigger DMA request enabled
Bit 9 CC1DE: Capture/Compare 1 DMA request enable
0: CC1 DMA request disabled
1: CC1 DMA request enabled
Bit 8 UDE: Update DMA request enable
0: Update DMA request disabled
1: Update DMA request enabled
Bit 7 BIE: Break interrupt enable
0: Break interrupt disabled
1: Break interrupt enabled
Bit 6 TIE: Trigger interrupt enable
0: Trigger interrupt disabled
1: Trigger interrupt enabled
Bit 5 COMIE: COM interrupt enable
0: COM interrupt disabled
1: COM interrupt enabled
Bits 4:2 Reserved, must be kept at reset value.
Bit 1 CC1IE: Capture/Compare 1 interrupt enable
0: CC1 interrupt disabled
1: CC1 interrupt enabled
Bit 0 UIE: Update interrupt enable
0: Update interrupt disabled
1: Update interrupt enabled
17.4.5 TIM16 status register (TIMx_SR)
Address offset: 0x10
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | CC1OF | Res | BIF | TIF | COMIF | Res | Res | Res | CC1IF | UIF |
| rc_w0 | rc_w0 | rc_w0 | rc_w0 | rc_w0 | rc_w0 |
Bits 15:10 Reserved, must be kept at reset value.
Bit 9 CC1OF: Capture/Compare 1 overcapture flag
This flag is set by hardware only when the corresponding channel is configured in input capture mode. It is cleared by software by writing it to '0'.
0: No overcapture has been detected
1: The counter value has been captured in TIMx_CCR1 register while CC1IF flag was already set
Bit 8 Reserved, must be kept at reset value.
Bit 7 BIF: Break interrupt flag
This flag is set by hardware as soon as the break input goes active. It can be cleared by software if the break input is not active.
0: No break event occurred
1: An active level has been detected on the break input
Bit 6 TIF: Trigger interrupt flag
This flag is set by hardware on trigger event (active edge detected on TRGI input when the slave mode controller is enabled in all modes but gated mode, both edges in case gated mode is selected). It is cleared by software.
0: No trigger event occurred
1: Trigger interrupt pending
Bit 5 COMIF: COM interrupt flag
This flag is set by hardware on a COM event (once the capture/compare control bits –CCxE, CCxNE, OCxM– have been updated). It is cleared by software.
0: No COM event occurred
1: COM interrupt pending
Bits 4:2 Reserved, must be kept at reset value.
Bit 1 CC1IF: Capture/Compare 1 interrupt flag
If channel CC1 is configured as output:
This flag is set by hardware when the counter matches the compare value. It is cleared by software.
0: No match.
1: The content of the counter TIMx_CNT matches the content of the TIMx_CCR1 register. When the contents of TIMx_CCR1 are greater than the contents of TIMx_ARR, the CC1IF bit goes high on the counter overflow
If channel CC1 is configured as input:
This bit is set by hardware on a capture. It is cleared by software or by reading the TIMx_CCR1 register.
0: No input capture occurred
1: The counter value has been captured in TIMx_CCR1 register (An edge has been detected on IC1 which matches the selected polarity)
Bit 0 UIF: Update interrupt flag
This bit is set by hardware on an update event. It is cleared by software.
0: No update occurred.
1: Update interrupt pending. This bit is set by hardware when the registers are updated:
- - At overflow regarding the repetition counter value (update if repetition counter = 0) and if the UDIS=0 in the TIMx_CR1 register.
- - When CNT is reinitialized by software using the UG bit in TIMx_EGR register, if URS=0 and UDIS=0 in the TIMx_CR1 register.
17.4.6 TIM16 event generation register (TIMx_EGR)
Address offset: 0x14
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | Res | Res | BG | TG | COMG | Res | Res | Res | CC1G | UG |
| w | w | w | w | w |
Bits 15:8 Reserved, must be kept at reset value.
Bit 7 BG: Break generation
This bit is set by software in order to generate an event, it is automatically cleared by hardware.
0: No action.
1: A break event is generated. MOE bit is cleared and BIF flag is set. Related interrupt or DMA transfer can occur if enabled.
Bit 6 TG: Trigger generation
This bit is set by software in order to generate an event, it is automatically cleared by hardware.
0: No action
1: The TIF flag is set in TIMx_SR register. Related interrupt or DMA transfer can occur if enabled
Bit 5 COMG: Capture/Compare control update generation
This bit can be set by software, it is automatically cleared by hardware.
0: No action
1: When the CCPC bit is set, it is possible to update the CCxE, CCxNE and OCxM bits
Note: This bit acts only on channels that have a complementary output.
Bits 4:2 Reserved, must be kept at reset value.
Bit 1 CC1G: Capture/Compare 1 generation
This bit is set by software in order to generate an event, it is automatically cleared by hardware.
0: No action.
1: A capture/compare event is generated on channel 1:
If channel CC1 is configured as output:
CC1IF flag is set, Corresponding interrupt or DMA request is sent if enabled.
If channel CC1 is configured as input:
The current value of the counter is captured in TIMx_CCR1 register. The CC1IF flag is set, the corresponding interrupt or DMA request is sent if enabled. The CC1OF flag is set if the CC1IF flag was already high.
Bit 0 UG: Update generation
This bit can be set by software, it is automatically cleared by hardware.
0: No action.
1: Reinitialize the counter and generates an update of the registers. Note that the prescaler counter is cleared too (anyway the prescaler ratio is not affected).
17.4.7 TIM16 capture/compare mode register 1 (TIMx_CCMR1)
Address offset: 0x18
Reset value: 0x0000
The channels can be used in input (capture mode) or in output (compare mode). The direction of a channel is defined by configuring the corresponding CCxS bits. All the other bits of this register have a different function in input and in output mode. For a given bit, OCxx describes its function when the channel is configured in output, ICxx describes its function when the channel is configured in input. So you must take care that the same bit can have a different meaning for the input stage and for the output stage.
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | OC1M[3] |
| Res. | |||||||||||||||
| rw | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res | Res | Res | Res | Res | Res | Res | Res | Res | OC1M[2:0] | OC1PE | OC1FE | CC1S[1:0] | |||
| IC1F[3:0] | IC1PSC[1:0] | ||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | |||||||||
Output compare mode:
Bits 31:17 Reserved, always read as 0
Bits 16, 6:4 OC1M[3:0]: Output Compare 1 mode (bits 3 to 0)
These bits define the behavior of the output reference signal OC1REF from which OC1 and OC1N are derived. OC1REF is active high whereas OC1 and OC1N active level depends on CC1P and CC1NP bits.
00000: Frozen - The comparison between the output compare register TIMx_CCR1 and the counter TIMx_CNT has no effect on the outputs.
00001: Set channel 1 to active level on match. OC1REF signal is forced high when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).
00010: Set channel 1 to inactive level on match. OC1REF signal is forced low when the counter TIMx_CNT matches the capture/compare register 1 (TIMx_CCR1).
00011: Toggle - OC1REF toggles when TIMx_CNT=TIMx_CCR1.
00100: Force inactive level - OC1REF is forced low.
00101: Force active level - OC1REF is forced high.
00110: PWM mode 1 - Channel 1 is active as long as TIMx_CNT<TIMx_CCR1 else inactive.
00111: PWM mode 2 - Channel 1 is inactive as long as TIMx_CNT<TIMx_CCR1 else active.
1000: Retriggerable OPM mode 1 - In up-counting mode, the channel is active until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 1 and the channels becomes active again at the next update.
1001: Retriggerable OPM mode 2 - In up-counting mode, the channel is inactive until a trigger event is detected (on TRGI signal). Then, a comparison is performed as in PWM mode 2 and the channels becomes inactive again at the next update.
All other values: Reserved
Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).
2: In PWM mode 1 or 2, the OCREF level changes only when the result of the comparison changes or when the output compare mode switches from "frozen" mode to "PWM" mode.
Bit 3 OC1PE: Output Compare 1 preload enable
0: Preload register on TIMx_CCR1 disabled. TIMx_CCR1 can be written at anytime, the new value is taken in account immediately.
1: Preload register on TIMx_CCR1 enabled. Read/Write operations access the preload register. TIMx_CCR1 preload value is loaded in the active register at each update event.
Note: 1: These bits can not be modified as long as LOCK level 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S='00' (the channel is configured in output).
2: The PWM mode can be used without validating the preload register only in one pulse mode (OPM bit set in TIMx_CR1 register). Else the behavior is not guaranteed.
Bit 2 OC1FE: Output Compare 1 fast enable
This bit is used to accelerate the effect of an event on the trigger in input on the CC output.
0: CC1 behaves normally depending on counter and CCR1 values even when the trigger is ON. The minimum delay to activate CC1 output when an edge occurs on the trigger input is 5 clock cycles.
1: An active edge on the trigger input acts like a compare match on CC1 output. Then, OC is set to the compare level independently of the result of the comparison. Delay to sample the trigger input and to activate CC1 output is reduced to 3 clock cycles. OC1FE acts only if the channel is configured in PWM1 or PWM2 mode.
Bits 1:0 CC1S: Capture/Compare 1 selection
This bit-field defines the direction of the channel (input/output) as well as the used input.
00: CC1 channel is configured as output
01: CC1 channel is configured as input, IC1 is mapped on TI1:
1x: Reserved
Note: CC1S bits are writable only when the channel is OFF (CC1E = '0' in TIMx_CCER).
Input capture mode
Bits 31:8 Reserved, must be kept at reset value.
Bits 7:4 IC1F[3:0]: Input capture 1 filter
This bit-field defines the frequency used to sample TI1 input and the length of the digital filter applied to TI1. The digital filter is made of an event counter in which N events are needed to validate a transition on the output:
0000: No filter, sampling is done at fDTS
0001: fSAMPLING=fCK_INT, N=2
0010: fSAMPLING=fCK_INT, N=4
0011: fSAMPLING=fCK_INT, N=8
0100: fSAMPLING=fDTS/2, N=
0101: fSAMPLING=fDTS/2, N=8
0110: fSAMPLING=fDTS/4, N=6
0111: fSAMPLING=fDTS/4, N=8
1000: fSAMPLING=fDTS/8, N=6
1001: fSAMPLING=fDTS/8, N=8
1010: fSAMPLING=fDTS/16, N=5
1011: fSAMPLING=fDTS/16, N=6
1100: fSAMPLING=fDTS/16, N=8
1101: fSAMPLING=fDTS/32, N=5
1110: fSAMPLING=fDTS/32, N=6
1111: fSAMPLING=fDTS/32, N=8
Bits 3:2 IC1PSC: Input capture 1 prescaler
This bit-field defines the ratio of the prescaler acting on CC1 input (IC1).
The prescaler is reset as soon as CC1E=’0’ (TIMx_CCER register).
00: no prescaler, capture is done each time an edge is detected on the capture input.
01: capture is done once every 2 events
10: capture is done once every 4 events
11: capture is done once every 8 events
Bits 1:0 CC1S: Capture/Compare 1 Selection
This bit-field defines the direction of the channel (input/output) as well as the used input.
00: CC1 channel is configured as output
01: CC1 channel is configured as input, IC1 is mapped on TI1
1x: Reserved
Note: CC1S bits are writable only when the channel is OFF (CC1E = ‘0’ in TIMx_CCER).
17.4.8 TIM16 capture/compare enable register (TIMx_CCER)
Address offset: 0x20
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | CC1NP | CC1NE | CC1P | CC1E |
| rw | rw | rw | rw |
Bits 15:4 Reserved, must be kept at reset value.
Bit 3 CC1NP: Capture/Compare 1 complementary output polarity
CC1 channel configured as output:
0: OC1N active high
1: OC1N active low
CC1 channel configured as input:
This bit is used in conjunction with CC1P to define the polarity of TI1FP1. Refer to the description of CC1P.
Note: 1. This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register) and CC1S="00" (the channel is configured in output).
2. On channels that have a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1NP active bit takes the new value from the preloaded bit only when a commutation event is generated.
Bit 2 CC1NE: Capture/Compare 1 complementary output enable
0: Off - OC1N is not active. OC1N level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.
1: On - OC1N signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1E bits.
Bit 1 CC1P: Capture/Compare 1 output polarity
CC1 channel configured as output:
0: OC1 active high
1: OC1 active low
CC1 channel configured as input:
The CC1NP/CC1P bits select the polarity of TI1FP1 for trigger or capture operations.
00: Non-inverted/rising edge. The circuit is sensitive to TIxFP1 rising edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode).
01: Inverted/falling edge. The circuit is sensitive to TIxFP1 falling edge (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is inverted (trigger operation in gated mode).
10: Reserved, do not use this configuration.
11: Non-inverted/both edges. The circuit is sensitive to both TIxFP1 rising and falling edges (capture or trigger operations in reset, external clock or trigger mode), TIxFP1 is not inverted (trigger operation in gated mode).
Note: 1. This bit is not writable as soon as LOCK level 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).
2. On channels that have a complementary output, this bit is preloaded. If the CCPC bit is set in the TIMx_CR2 register then the CC1P active bit takes the new value from the preloaded bit only when a Commutation event is generated.
Bit 0 CC1E: Capture/Compare 1 output enable
CC1 channel configured as output:
0: Off - OC1 is not active. OC1 level is then function of MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.
1: On - OC1 signal is output on the corresponding output pin depending on MOE, OSSI, OSSR, OIS1, OIS1N and CC1NE bits.
CC1 channel configured as input:
This bit determines if a capture of the counter value can actually be done into the input capture/compare register 1 (TIMx_CCR1) or not.
0: Capture disabled
1: Capture enabled
Table 55. Output control bits for complementary OCx and OCxN channels with break feature
| Control bits | Output states(1) | |||||
|---|---|---|---|---|---|---|
| MOE bit | OSSI bit | OSSR bit | CCxE bit | CCxNE bit | OCx output state | OCxN output state |
| 1 | X | X | 0 | 0 | Output Disabled (not driven by the timer: Hi-Z) OCx=0 OCxN=0, OCxN_EN=0 | |
| 0 | 0 | 1 | Output Disabled (not driven by the timer: Hi-Z) OCx=0 | OCxREF + Polarity OCxN=OCxREF XOR CCxNP | ||
| 0 | 1 | 0 | OCxREF + Polarity OCx=OCxREF XOR CCxP | Output Disabled (not driven by the timer: Hi-Z) OCxN=0 | ||
| X | 1 | 1 | OCREF + Polarity + dead-time | Complementary to OCREF (not OCREF) + Polarity + dead-time | ||
| 1 | 0 | 1 | Off-State (output enabled with inactive state) OCx=CCxP | OCxREF + Polarity OCxN=OCxREF XOR CCxNP | ||
| 1 | 1 | 0 | OCxREF + Polarity OCx=OCxREF XOR CCxP, OCx_EN=1 | Off-State (output enabled with inactive state) OCxN=CCxNP, OCxN_EN=1 | ||
| 0 | 0 | X | X | X | Output Disabled (not driven by the timer: Hi-Z) OCx=CCxP, OCxN=CCxNP | |
| 1 | 0 | 0 | Off-State (output enabled with inactive state) OCx=CCxP, OCxN=CCxNP | |||
| 0 | 1 | Asynchronously: OCx=CCxP, OCxN=CCxNP | ||||
| 1 | 0 | Then if the clock is present: OCx=OISx and OCxN=OISxN after a dead-time, assuming that OISx and OISxN do not correspond to OCx and OCxN both in active state | ||||
| 1 | 1 | |||||
1. When both outputs of a channel are not used (control taken over by GPIO controller), the OISx, OISxN, CCxP and CCxNP bits must be kept cleared.
Note: The state of the external I/O pins connected to the complementary OCx and OCxN channels depends on the OCx and OCxN channel state and AFIO registers.
17.4.9 TIM16 counter (TIMx_CNT)
Address offset: 0x24
Reset value: 0x0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| UIF CPY | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| r | |||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CNT[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bit 31 UIFCPY: UIF Copy
This bit is a read-only copy of the UIF bit of the TIMx_ISR register. If the UIFREMAP bit in TIMx_CR1 is reset, bit 31 is reserved and read as 0.
Bits 30:16 Reserved, must be kept at reset value.
Bits 15:0 CNT[15:0]: Counter value
17.4.10 TIM16 prescaler (TIMx_PSC)
Address offset: 0x28
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PSC[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 PSC[15:0]: Prescaler value
The counter clock frequency (CK_CNT) is equal to \(f_{CK\_PSC} / (PSC[15:0] + 1)\).
PSC contains the value to be loaded in the active prescaler register at each update event (including when the counter is cleared through UG bit of TIMx_EGR register or through trigger controller when configured in “reset mode”).
17.4.11 TIM16 auto-reload register (TIMx_ARR)
Address offset: 0x2C
Reset value: 0xFFFF
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARR[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 ARR[15:0]: Prescaler value
ARR is the value to be loaded in the actual auto-reload register.
Refer to the Section 17.3.1: Time-base unit for more details about ARR update and behavior.
The counter is blocked while the auto-reload value is null.
17.4.12 TIM16 repetition counter register (TIMx_RCR)
Address offset: 0x30
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | Res | Res | REP[7:0] | |||||||
| rw | rw | rw | rw | rw | rw | rw | rw | ||||||||
Bits 15:8 Reserved, must be kept at reset value.
Bits 7:0 REP[7:0]: Repetition counter value
These bits allow the user to set-up the update rate of the compare registers (i.e. periodic transfers from preload to active registers) when preload registers are enable, as well as the update interrupt generation rate, if this interrupt is enable.
Each time the REP_CNT related downcounter reaches zero, an update event is generated and it restarts counting from REP value. As REP_CNT is reloaded with REP value only at the repetition update event U_RC, any write to the TIMx_RCR register is not taken in account until the next repetition update event.
It means in PWM mode (REP+1) corresponds to the number of PWM periods in edge-aligned mode.
17.4.13 TIM16 capture/compare register 1 (TIMx_CCR1)
Address offset: 0x34
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CCR1[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 CCR1[15:0]: Capture/Compare 1 value
If channel CC1 is configured as output:
CCR1 is the value to be loaded in the actual capture/compare 1 register (preload value).
It is loaded permanently if the preload feature is not selected in the TIMx_CCMR1 register (bit OC1PE). Else the preload value is copied in the active capture/compare 1 register when an update event occurs.
The active capture/compare register contains the value to be compared to the counter TIMx_CNT and signaled on OC1 output.
If channel CC1 is configured as input:
CCR1 is the counter value transferred by the last input capture 1 event (IC1).
17.4.14 TIM16 break and dead-time register (TIMx_BDTR)
Address offset: 0x44
Reset value: 0x0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| Res | Res | Res | BKBID | Res | BKDSRM | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| rw | rw | ||||||||||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| MOE | AOE | BKP | BKE | OSSR | OSSI | LOCK[1:0] | DTG[7:0] | ||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Note: As the BKBID, BKDSRM, AOE, BKP, BKE, OSSI, OSSR, DTG[7:0] bits and all used bits of TIMx_AF1 register may be write-locked depending on the LOCK configuration, it may be necessary to configure all of them during the first write access to the TIMx_BDTR register.
Bits 31:29 Reserved, must be kept at reset value.
Bit 28 BKBID: Break Bidirectional
0: Break input BRK in input mode
1: Break input BRK in bidirectional mode
In the bidirectional mode (BKBID bit set to 1), the break input is configured both in input mode and in open drain output mode. Any active break event asserts a low logic level on the Break input to indicate an internal break event to external devices.
Note: This bit cannot be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.
Bit 27 Reserved, must be kept at reset value.
Bit 26 BKDSRM: Break Disarm
0: Break input BRK is armed
1: Break input BRK is disarmed
This bit is cleared by hardware when no break source is active.
The BKDSRM bit must be set by software to release the bidirectional output control (opendrain output in Hi-Z state) and then be polled it until it is reset by hardware, indicating that the fault condition has disappeared.
Note: Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.
Bits 25:16 Reserved, must be kept at reset value.
Bit 15 MOE: Main output enable
This bit is cleared asynchronously by hardware as soon as the break input is active. It is set by software or automatically depending on the AOE bit. It is acting only on the channels which are configured in output.
0: OC and OCN outputs are disabled or forced to idle state depending on the OSSI bit.
1: OC and OCN outputs are enabled if their respective enable bits are set (CCxE, CCxNE in TIMx_CCER register)
See OC/OCN enable description for more details (Section 17.4.8: TIM16 capture/compare enable register (TIMx_CCER)).
Bit 14 AOE: Automatic output enable
0: MOE can be set only by software
1: MOE can be set by software or automatically at the next update event (if the break input is not be active)
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
Bit 13 BKP: Break polarity
0: Break input BRK is active low
1: Break input BRK is active high
Note: 1. This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
2. Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.
Bit 12 BKE: Break enable
0: Break inputs (BRK) disabled
1: Break inputs (BRK) enabled
Note: 1. This bit cannot be modified when LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register).
2. Any write operation to this bit takes a delay of 1 APB clock cycle to become effective.
Bit 11 OSSR: Off-state selection for Run mode
This bit is used when MOE=1 on channels that have a complementary output which are configured as outputs. OSSR is not implemented if no complementary output is implemented in the timer.
See OC/OCN enable description for more details (Section 17.4.8: TIM16 capture/compare enable register (TIMx_CCER)).
0: When inactive, OC/OCN outputs are disabled (the timer releases the output control which is taken over by the AFIO logic, which forces a Hi-Z state)
1: When inactive, OC/OCN outputs are enabled with their inactive level as soon as CCxE=1 or CCxNE=1 (the output is still controlled by the timer).
Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).
Bit 10 OSSI: Off-state selection for Idle mode
This bit is used when MOE=0 on channels configured as outputs.
See OC/OCN enable description for more details (Section 17.4.8: TIM16 capture/compare enable register (TIMx_CCER)).
0: When inactive, OC/OCN outputs are disabled (OC/OCN enable output signal=0)
1: When inactive, OC/OCN outputs are forced first with their idle level as soon as CCxE=1 or CCxNE=1. OC/OCN enable output signal=1)
Note: This bit can not be modified as soon as the LOCK level 2 has been programmed (LOCK bits in TIMx_BDTR register).
Bits 9:8 LOCK[1:0]: Lock configuration
These bits offer a write protection against software errors.
00: LOCK OFF - No bit is write protected
01: LOCK Level 1 = DTG bits in TIMx_BDTR register, OISx and OISxN bits in TIMx_CR2 register, BKE/BKP/AOE/BKBID/BKDSRM bits in TIMx_BDTR register and all used bits in TIMx_AF1 register can no longer be written.
10: LOCK Level 2 = LOCK Level 1 + CC Polarity bits (CCxP/CCxNP bits in TIMx_CCER register, as long as the related channel is configured in output through the CCxS bits) as well as OSSR and OSSI bits can no longer be written.
11: LOCK Level 3 = LOCK Level 2 + CC Control bits (OCxM and OCxPE bits in TIMx_CCMRx registers, as long as the related channel is configured in output through the CCxS bits) can no longer be written.
Note: The LOCK bits can be written only once after the reset. Once the TIMx_BDTR register has been written, their content is frozen until the next reset.
Bits 7:0 DTG[7:0]: Dead-time generator setup
This bit-field defines the duration of the dead-time inserted between the complementary outputs. DT correspond to this duration.
\(DTG[7:5]=0xx \Rightarrow DT=DTG[7:0] \times t_{dtg}\) with \(t_{dtg}=t_{DTS}\)
\(DTG[7:5]=10x \Rightarrow DT=(64+DTG[5:0]) \times t_{dtg}\) with \(T_{dtg}=2 \times t_{DTS}\)
\(DTG[7:5]=110 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=8 \times t_{DTS}\)
\(DTG[7:5]=111 \Rightarrow DT=(32+DTG[4:0]) \times t_{dtg}\) with \(T_{dtg}=16 \times t_{DTS}\)
Example if \(T_{DTS}=125\) ns (8 MHz), dead-time possible values are:
0 to 15875 ns by 125 ns steps,
16 μs to 31750 ns by 250 ns steps,
32 μs to 63 μs by 1 μs steps,
64 μs to 126 μs by 2 μs steps
Note: This bit-field can not be modified as long as LOCK level 1, 2 or 3 has been programmed (LOCK bits in TIMx_BDTR register).
17.4.15 TIM16 DMA control register (TIMx_DCR)
Address offset: 0x48
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | DBL[4:0] | Res | Res | Res | DBA[4:0] | ||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | ||||||
Bits 15:13 Reserved, must be kept at reset value.
Bits 12:8 DBL[4:0]: DMA burst length
This 5-bit field defines the length of DMA transfers (the timer recognizes a burst transfer when a read or a write access is done to the TIMx_DMAR address), i.e. the number of transfers. Transfers can be in half-words or in bytes (see example below).
00000: 1 transfer,
00001: 2 transfers,
00010: 3 transfers,
...
10001: 18 transfers.
Bits 7:5 Reserved, must be kept at reset value.
Bits 4:0 DBA[4:0]: DMA base address
This 5-bit field defines the base-address for DMA transfers (when read/write access are done through the TIMx_DMAR address). DBA is defined as an offset starting from the address of the TIMx_CR1 register.
Example:
00000: TIMx_CR1,
00001: TIMx_CR2,
00010: Reserved,
...
Example: Let us consider the following transfer: DBL = 7 transfers and DBA = TIMx_CR1. In this case the transfer is done to/from 7 registers starting from the TIMx_CR1 address.
17.4.16 TIM16 DMA address for full transfer (TIMx_DMAR)
Address offset: 0x4C
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DMAB[15:0] | |||||||||||||||
| rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw | rw |
Bits 15:0 DMAB[15:0]: DMA register for burst accesses
A read or write operation to the DMAR register accesses the register located at the address
where TIMx_CR1 address is the address of the control register 1, DBA is the DMA base address configured in TIMx_DCR register, DMA index is automatically controlled by the DMA transfer, and ranges from 0 to DBL (DBL configured in TIMx_DCR).
17.4.17 TIM16 option register 1 (TIM16_OR)
Address offset: 0x50
Reset value: 0x0000
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | TI1_RMP[1:0] | Res. | |
| rw | rw | ||||||||||||||
Bits 31:3 Reserved, must be kept at reset value.
Bits 2:1 TI1_RMP[1:0]: Timer 16 input 1 connection
This bit is set and cleared by software.
00: TIM16 TI1 is connected to GPIO
01: TIM16 TI1 is connected to LCO
10: Reserved
11: TIM16 TI1 is connected to MCO
Bit 0 Reserved, must be kept at reset value.

17.4.18 TIM16 alternate function option register 2 (TIMx_AF1)
Address offset: 0x60
Reset value: 0x0001
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res | Res | Res | Res | Res | Res | BKINP | Res | Res | Res | Res | Res | Res | Res | Res | BKINE |
| rw | rw |
Bits 31:10 Reserved, must be kept at reset value.
Bit 9 BKINP: BRK BKIN input polarity.
This bit selects the BKIN alternate function input sensitivity. It must be programmed together with the BKP polarity bit.
0: BKIN input is active low.
1: BKIN input is active high.
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)
Bits 8:1 Reserved, must be kept at reset value.
Bit 0 BKINE: BRK BKIN enable.
This bit enables the BKIN alternate function input for the timer's BRK input. BKIN input is ORed with the other enabled BRK sources.
0: BKIN input disabled.
1: BKIN input enabled.
Note: This bit can not be modified as long as LOCK level 1 has been programmed (LOCK bits in TIMx_BDTR register)
17.4.19 TIM16 input selection register (TIM16_TISEL)
Address offset: 0x68
Reset value: 0x0000
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | Res. | TI1SEL[3:0] | |||
| rw | rw | rw | rw | ||||||||||||
Bits 31:4 Reserved, must be kept at reset value.
Bits 3:0 TI1SEL[3:0]: selects TI1[0] to TI1[15] input
0000: TIMx_CH1 input
Others: Reserved
17.4.20 TIM16 register map
TIM16 registers are mapped as 16-bit addressable registers as described in the table below:
Table 56. TIM16 register map and reset values
| Offset | Register | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0x00 | TIMx_CR1 | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | UIFREMA | Res | CKD [1:0] | ARPE | Res | Res | Res | OPM | URS | UDIS | CEN | |
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||
| 0x04 | TIMx_CR2 | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | OIS1N | OIS1 | Res | MMS | CCDS | CCUS | Res | CCPC | |||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||
| 0x08 | TIMx_SMCR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | TS[4:3] | 0 | 0 | Res | Res | Res | SM[S3] | Res | Res | Res | Res | Res | Res | MSM | TS[2:0] | Res | SM[S2:0] | |||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||
| 0x0C | TIMx_DIER | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | TDE | Res | Res | Res | CC1OF | CC1DE | UDE | OIS1 | TIE | COMIE | Res | Res | Res | CC1IE | UIE |
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||
| 0x10 | TIMx_SR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | CC1OF | Res | BIF | TIF | COMIF | Res | Res | Res | CC1IF | UIF |
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||
| 0x14 | TIMx_EGR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | BG | TG | COMG | Res | Res | Res | Res | CC1G | UG |
| Reset value | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||
| 0x18 | TIMx_CCMR1 Output Compare mode | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | OC1M[3] | Res | Res | Res | Res | Res | Res | Res | OC1M [2:0] | OC1PE | OC1FE | CC1S [1:0] | ||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||
| TIMx_CCMR1 Input Capture mode | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | IC1F[3:0] | IC1 PSC [1:0] | CC1S [1:0] | |||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||
| 0x20 | TIMx_CCER | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | CC1NP | CC1NE | CC1P | CC1E |
| Reset value | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||
| 0x24 | TIMx_CNT | UIFCPY or Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| Reset value | 0 | ||||||||||||||||||||||||||||||||
| 0x28 | TIMx_PSC | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| Reset value | |||||||||||||||||||||||||||||||||
| 0x2C | TIMx_ARR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res |
| Reset value |
| Offset | Register | 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0x30 | TIMx_RCR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | REP[7:0] | |||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||
| 0x34 | TIMx_CCR1 | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | CCR1[15:0] | |||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||
| 0x44 | TIMx_BDTR | Res | Res | Res | BKBID | Res | BKDSRM | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | MOE | AOE | BKP | BKE | OSSR | OSSI | LOCK[1:0] | DT[7:0] | ||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||
| 0x48 | TIMx_DCR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | DBL[4:0] | Res | Res | Res | DBA[4:0] | ||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||||||||
| 0x4C | TIMx_DMAR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | DMAB[15:0] | |||||||||||||||
| Reset value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |||||||||||||||||
| 0x50 | TIMx_OR | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | TI1_RMP[1:0] | Res | |
| Reset value | 0 | 0 | |||||||||||||||||||||||||||||||
| 0x60 | TIMx_AF1 | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | BKINP | Res | Res | Res | Res | Res | Res | Res | Res | BKINE |
| Reset value | 0 | 1 | |||||||||||||||||||||||||||||||
| 0x68 | TIMx_TISEL | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | Res | TI1SEL[3:0] | |||
| Reset value | 0 | 0 | 0 | 0 | |||||||||||||||||||||||||||||
Refer to Section 2.2.2: Memory map and register boundary addresses for the register boundary addresses.